Fire Safety Installations Building Act 1975, Fire and Rescue Service Act 1990, Fire and Rescue Service Regulation 2011 Building Fire Safety Regulation 2008, Queensland Development Code MP6.1 DEFINED TERMINOLOGY REGULATORY FRAMEWORK ANNUAL CERTIFICATION REQUIREMENTS Occupiers Statement to be prepared annually on behalf of the building occupier or owner where the building is vacant or unoccupied. The Occupiers statement must be kept with the buildings maintenance records and be produced upon demand by local government officers and authorised officers of the QFES. BUILDING OCCUPANCY TYPES REQUIRED TO COMPLY WITH SAFETY MEASURES REGULATIONS All Class 1b – 9c occupancy buildings as defined by Part A3.2 of the National Construction Code are required to be maintained regardless of floor area size or whether the building is occupied or vacant. A building treated as part of a coal mine for the purposes of the relevant legislation is excluded from the requirement. ADOPTION OF AS1851 Queensland Development Code MP6.1 requires all applicable maintenance to be performed in accordance with AS1851-2012 requirements. QUEENSLAND MELBOURNE SYDNEY BRISBANE PERTH HONG KONG

Upload: others

Post on 11-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QLD ESM attachment

Fire Safety Installations

Building Act 1975, Fire and Rescue Service Act 1990, Fire andRescue Service Regulation 2011Building Fire Safety Regulation 2008, Queensland DevelopmentCode MP6.1

D E F I N E D T E R M I N O L O G Y

R E G U L A T O R Y F R A M E W O R K

A N N U A L C E R T I F I C A T I O N R E Q U I R E M E N T S

Occupiers Statement to be prepared annually on behalf of thebuilding occupier or owner where the building is vacant orunoccupied. The Occupiers statement must be kept with thebuildings maintenance records and be produced upon demand bylocal government officers and authorised officers of the QFES.

B U I L D I N G O C C U P A N C Y T Y P E S R E Q U I R E D T OC O M P L Y W I T H S A F E T Y M E A S U R E S R E G U L A T I O N S

All Class 1b – 9c occupancy buildings as defined by Part A3.2 of theNational Construction Code are required to be maintainedregardless of floor area size or whether the building is occupied orvacant. A building treated as part of a coal mine for the purposesof the relevant legislation is excluded from the requirement.

A D O P T I O N O F A S 1 8 5 1

Queensland Development Code MP6.1 requires all applicablemaintenance to be performed in accordance with AS1851-2012requirements.

Q U E E N S L A N D

M E L B O U R N E S Y D N E Y B R I S B A N E P E R T H H O N G K O N G

Page 2: QLD ESM attachment

Air handling systemsEmergency lifts Emergency lighting Emergency power supply Emergency warning and intercommunication systemsExit signsFire detection and alarm systemsFire doorsetsFire extinguishersFire hose reelsFire hydrants (including boosters)Fire mainsFire shutters Smoke and heat venting systemsSmoke door setsSmoke exhaust systemsSolid core doorsSpecial automatic fire suppression systemsSprinklersStairwell pressurisation systems Other measures (includes additional fire safety installation orconditions that are required under the buildings alternativesolution under the Building Act 1975 of NCC Vol. 1 ClausesE1.10 and E2.3.

D E F I N E D F I R E S A F E T Y I N S T A L L A T I O N S

Queensland Development Code MP6.1 defines the following itemsas “prescribed fire safety installations”:

M E L B O U R N E S Y D N E Y B R I S B A N E P E R T H H O N G K O N G

Q U E E N S L A N D

Page 3: QLD ESM attachment

D E F I N E D F I R E S A F E T Y I N S T A L L A T I O N S C O N T .

Additional legislative maintenance requirements for all structuralfeatures that are fire safety installations such as structural fireprotection, penetrations in fire rated structures etc. are containedin the Fire and Rescue Services Act 1990.

Requirements for building occupiers to maintain path of travel toexits, exit doors and discharge from exits are also included in theBuilding Fire and Safety Regulation 2008.

M E L B O U R N E S Y D N E Y B R I S B A N E P E R T H H O N G K O N G

Q U E E N S L A N D

C O P Y R I G H T © 2 0 2 1 T E S G A L L R I G H T S R E S E R V E D

This info sheet is intended as a guide only and no reliance shouldbe placed solely on this document. While best endeavors weremade to concisely summarise detailed legislation and regulation attime of publication, the legislation and regulation can and does change and every circumstance is unique and requires individualand professional attention.

For detailed information, professional advice or for anyquestions you may have, please contact TESG on 1300 725 797or [email protected]