"R&Mfreenet" copper cables
Comprehensive range of twisted pair cables to set up the R&Mfreenet system Screened and unscreened cables Different jacket materials to meet safety standards Bandwidths up to 1.2 GHz All cables are 3P tested and listed All cables comply with the current standards
All cable values are measured after Installation Simulation
Installation Cables / Page 3Dec. 2005
Assortment of multi-pair cablesvoice backbones applications
Cable type Cable material Available lengths
Cat 3 U/UTP multi-pair LS0H 300 m reel
Cat 5e U/UTP multi-pair LS0H 300 m reel
Cat 3 F/UTP multi-pair LS0H 300 m reel
Cat 5e F/UTP multi-pair LS0H 300 m reel
Installation Cables / Page 4Dec. 2005
Assortment of 4 pair cablesdata applications
Cable type Cable material Available lengths
Cat. 5e U/UTP PVC and LS0H 500 m reel, 305 m boxCat. 6 U/UTP PVC and LS0H 500 m reelCat. 6 U/FTP LSFR0H 500 m reel
Cat. 5e F/UTP PVC and LS0H 500 m reel, 305 m boxCat. 5e SF/UTP PVC and LSFR0H 500 m reel
Cat. 6 S/FTP LS0H 500 m reel Cat. 7 S/FTP LSFR0H 500 m reel Multimedia S/FTP LSFR0H 500 m reel
Installation Cables / Page 5Dec. 2005
Cat. 5e, 6, 7 and Multimedia cables
Features
All cables comply with the ISO/IEC 11801, EN 50173, EN 50167, EN 50169, EIA/TIA 568A, prEN 50288-x-x specifications
Fulfill the stricter Cat. 5e requirements Fulfill the latest Cat. 6 and 7 requirement Fulfill the Industry proposed Standards where Official Standards are not available All cables are 3P tested and certified
100 ohm versions IEC color code Operational temperature range: -20°C to +75°C
Installation Cables / Page 6Dec. 2005
Fire, smoke density and gas tests requirements
IEC 60332-1: Test on one single cable
IEC 60332-3 Cat. C: Test on one bundle of cables
IEC 61034: Measuring the smoke density under the defined conditions
IEC 60754: Measuring the halogen gases during the combustion of plastic
Installation Cables / Page 7Dec. 2005
IEC 60332-1 fire testfire propagation
A gas burner is held against the cable for 1 minute continuously.
After 1 minute the gas burner is switched off. The cable must extinguish on its own. The burnt zone must not exceed 425 mm.
Simple test
PVC and LS0H pass this test
Installation Cables / Page 8Dec. 2005
IEC 60332-3c fire test on bundles of cables fire propagation
Complete fire test. Carried out in a special fire chamber.
Approx. 100 pieces of cables required.
Fire duration 20 min. The flames must only spread on a height of 2.5m.
FR (Fire Retardant) cables have special additives.
Only LSFR0H pass this test.
Installation Cables / Page 9Dec. 2005
IEC 61034 smoke density test
Measuring the smoke density to assure escaping routes visibility during fire
PVC produces thick, black smoke (visibility ~ 10%). Test fails
Smoke doesn’t allow visibility of safety exits
Problematical in the cabling in air shafts.
LS (Low Smoke) cables produce less smoke (visibility ~ 90%). Test passes
Safety signs are visible.
People can be localized and rescued.
Installation Cables / Page 10Dec. 2005
IEC 60754 measuring halogen content of gases
Measuring the quantity of halogen content produced during the combustion
of materials of the cables
Halogen gases corrosiveness has double negative effects on:
Human – intoxicate people causing death before fire
Equipment – water used during fire extinguishing will contain chlorine which is highly corrosive for electronics
PVC contains elements which release halogen gas during combustion or carbonization
0H (Zero Halogen) cables produce no halogen gases.
Installation Cables / Page 11Dec. 2005
Features Multi-pair cables for telephonic
applications. Suitable for voice, video (and data)
transmission at frequencies of up to 16 MHz.
Dimension: pair x2x0.5 mm (AWG24). Versions: 25, 50 or 100 pairs. U/UTP or F/UTP versions. LS0H cable jacket (IEC 332-1)
Multi pair riser cables: Cat. 3
Installation Cables / Page 12Dec. 2005
Features Multi-pair cables for telephonic
applications. Suitable for voice, video (and data)
transmission at frequencies of up to 100 MHz.
Dimension: pair x2x0.5 mm (AWG24). Versions: 25, 50 or 100 pairs. U/UTP or F/UTP versions. LS0H cable jacket (IEC 332-1)
Multi pair riser cables: Cat. 5e
Installation Cables / Page 13Dec. 2005
Features
Unscreened 100 Ω installation cables.
4 pairs or Siamese (2x4pairs)
0.5 mm conductor diameter.
Electrical values far better than cabling Standards
Plastic foil as protection; no cutting into the conductor insulation.
PVC or LS0H cable jackets.
5.5 mm overall diameter (4 pair version).
Installation cables, Cat. 5e, U/UTP
Installation Cables / Page 14Dec. 2005
Features
Unscreened 100 Ω installation cables
4 pairs only (no Siamese version).
0.57 mm conductor diameter.
7.1 mm max overall diameter.
Inner spacer to improve NEXT values.
Electrical values far better than cabling standard requirement even above 250 MHz
PVC and LS0H cable jackets.
Installation cables, Cat. 6, U/UTP
Installation Cables / Page 15Dec. 2005
Installation cables, Cat. 6a, U/UTP10G solution
Features
Patented WARP technology
Unscreened 100 Ω cable (no Siamese version).
.56mm conductor diameter
8.6mm overall diameter
Inner spacer to improve NEXT value
Aluminum interrupted foil to equalize ANEXT
without increasing excessively the diameter
Electrical values far better than cabling standard
requirement even above 650 MHz
LS0H cable jackets.
Installation Cables / Page 16Dec. 2005
Features
4 pairs individually foiled 100 Ω
Siamese version available
0.55 mm conductor diameter.
7 mm max (4 pairs version) overall diameter
Greatly improved NEXT values.
Electrical values far better than cabling standard requirement even above 250 MHz
LS0H cable jackets.
Installation cables, Cat. 6, U/FTP
Installation Cables / Page 17Dec. 2005
Installation cables, Cat. 5e, F/UTP
Features
Aluminum foil-screened, 100 Ω cables.
4 pairs or Siamese (2x4 pairs) version.
0.5 mm conductor diameter.
6.1 mm overall diameter.
Drain wire (0.5 mm) present
Mylar tape present
PVC and LS0H cable jackets.
Installation Cables / Page 18Dec. 2005
Installation cables, Cat. 5e, SF-UTP
Features
Braided/foil-screened, 100 Ω installation cable: alu-foil and tin-plated copper braid for high and low frequency interference fields.
4 pairs or Siamese (2x4 pairs).
0.5 mm conductor diameter.
6.5 mm overall diameter.
PVC, LS0H and LSFR0H cable jackets.
Installation Cables / Page 19Dec. 2005
Features
4 Pair-screened 100 Ω installation cable.
4 pairs or Siamese version
0.55 mm conductor diameter.
7.4 mm overall diameter
41% surface covered by braid.
Cable trimmed to a small overall diameter (7.4 mm) and best performance (Cat. 7).
LS0H cable jacket.
Excellent NEXT AND ANEXT
> 30dB ACR at 600 MHz.
Installation cable Cat. 6e (600MHz), S/FTP
Installation Cables / Page 20Dec. 2005
Installation cables Cat. 7, S-FTP
Features
4 Pair-screened 100 Ω installation cable.
4 pairs or Siamese version
0.58 mm conductor diameter.
7.9 mm overall diameter
65% surface covered by braid.
LSFR0H cable jacket.
Excellent NEXT AND ANEXT
> 35dB ACR at 600 MHz.
Installation Cables / Page 21Dec. 2005
Features
Individually shielded pairs with overall, shielding braid.
Flame retardant/zero halogen according to IEC 332-3c.
4 pairs or 2x4 pairs.
0.64 mm conductor diameter.
8.2 mm overall diameter
65% optical braid coverage.
Excellent NEXT AND ANEXT
> 17dB ACR at 1.2GHz.
Installation cables Cat. 7 (1200 MHz), S-FTP