Engineering Form Questionnaire: HALFEN DETAN Rod Systems
HALFEN USA Inc. 8521 F.M. 1976 P.O. Box 547 Converse, TX 78109 Phone: +1 800.423.9140 Fax: +1 877.683.4910Email: [email protected]
HALFEN USA Inc.
NOTESTechnical and design changes reserved. The information in this publication is based on state-of-the-art technology at the time of publication. We reserve the right to make technical and design changes at any time. HALFEN GmbH shall not accept liability for the accuracy of the information in this publication or for any printing errors.
D-1
06-U
SA -
02/1
5 PD
F (1
/3)
02/
15
201
5 H
ALF
EN G
mbH
, Ger
man
yap
plie
s al
so t
o co
pyin
g in
ext
ract
s.
*Project Name:
*Project Address:
Building type:
*Company:
*Contact Person:
Email:
The DETAN Tension Rod System is available in hot dip galvanized carbon steel and stainless steel for multiple conditions. The system consists of rods and a comprehensive range of matching accessories such as anchor disks, cross couplers, couplers with lug nuts, and more. This engineering form helps us to collect all the information we need to engineer, quote, and fabricate the rods to fit your requirements perfectly. Your success and satisfaction are our priorities. Please fill out the form carefully and provide as much information as possible to avoid further queries and to make sure that we can respond to you as quickly as possible. Please specify the units for your dimensions. You can add multiple different conditions, using one line per condition. HALFEN defines the system length as the pin-to-pin-length between the connection pins. Feel free to provide the drawings so that we can double check the dimensions given. Please check our Technical Product Information available on www.halfenusa.com for more information, such as availability of different diameters in different finishes. Thank you.
*City, State, ZIP:
*Phone:
*Business type:
Project Information (Note: *mandatory information)
Contact Information (Note: *mandatory information)
Please complete the form below and send to [email protected] or your local sales representative.
Please visit www.halfenusa.com to find the sales representative responsible for your state.
Comments:
[1/3]
-
Engineering Form Questionnaire: HALFEN DETAN Rod Systems
HALFEN USA Inc. 8521 F.M. 1976 P.O. Box 547 Converse, TX 78109 Phone: +1 800.423.9140 Fax: +1 877.683.4910Email: [email protected]
HALFEN USA Inc.
NOTESTechnical and design changes reserved. The information in this publication is based on state-of-the-art technology at the time of publication. We reserve the right to make technical and design changes at any time. HALFEN GmbH shall not accept liability for the accuracy of the information in this publication or for any printing errors.
D-1
06-U
SA -
02/1
5 PD
F (3
/3)
02/
15
201
5 H
ALF
EN G
mbH
, Ger
man
yap
plie
s al
so t
o co
pyin
g in
ext
ract
s.
*Project Name:
coupler lug-coupler
System-diameter dS
Tension Rod and Compression Rod conditionsTension Rod
System-diameter DS System-diameter dS
System length L
System length L
Compression Rod
Condition
Tension RodCompression
Rod*
System Length L* [Inches]
System Diameter ds** [mm]
Tension/ pressure*** load (ULS)**
[lbs]
Quantity of condition*no coupler* coupler* lug-coupler*
1
2
3
4
5
6
7
8
9
10
System/Material *Finish
Carbon Steel System Galvanized
System/Material *Finish
Polished
Hand PolishedStainless Steel System
Note: * mandatory specifications** Give load or system
diameter if loads or dimensions are metric, please show units
*** Pressure loads work for compression rods only!
[2/3]
-
Engineering Form Questionnaire: HALFEN DETAN Rod Systems
HALFEN USA Inc. 8521 F.M. 1976 P.O. Box 547 Converse, TX 78109 Phone: +1 800.423.9140 Fax: +1 877.683.4910Email: [email protected]
HALFEN USA Inc.
NOTESTechnical and design changes reserved. The information in this publication is based on state-of-the-art technology at the time of publication. We reserve the right to make technical and design changes at any time. HALFEN GmbH shall not accept liability for the accuracy of the information in this publication or for any printing errors.
Cross Bracing conditions
*with cross coupler *with anchor disk
System/Material *Finish
Carbon Steel System Galvanized
System/Material *Finish
Polished
Hand PolishedStainless Steel System
*Project Name:
Condition
Cross bracingSystem Height
H* [Inches]System Width W* [Inches]
System Diameter ds** [mm]
Tension load (ULS)** [lbs]
Quantity of condition*With cross
coupler*With
anchor disc*
11
12
13
14
15
16
17
18
19
20
Note: * mandatory specifications** Give load or system
diameter if loads or dimensions are metric, please show units
D-1
06-U
SA -
02/1
5 PD
F (2
/3)
02/
15
201
5 H
ALF
EN G
mbH
, Ger
man
yap
plie
s al
so t
o co
pyin
g in
ext
ract
s.
[3/3]
Syste
m dia
m. d s
Syste
m dia
m. d s
Width W [Inches]
Hei
ght
H [
Inch
es]
Width W [Inches]
Hei
ght
H [
Inch
es]
City State ZIP: Project Address: Building type: -Company: Phone: Contact Person: Kombinationsfeld1: -Email: Comments: Project Name:
1:
Text1: 2:
Text5: Text6: 3:
4:
5:
6:
Text21: 7:
8:
9:
10:
11:
Text2: Text3: Text4: Text7: Text8: Text9: Text10: Text11: Text12: Text16: Text15: Text14: Text13: Text20: Text19: Text18: Text17: Text22: Text23: Text26: Text24: Text28: Text27: Text25: Text29: Text32: Text31: Text30: Text33: Text34: Text35: Text36: Text39: Text38: Text37: Text40: 11-3: 11-4: 11-5: 11-6: 11-7: 12-3: 12-4: 12-5: 12-6: 12-7: 13-7: 13-6: 13-5: 13-4: 13-3: 14-7: 14-6: 14-5: 14-4: 14-3: 15-4: 15-7: 15-6: 15-5: 15-3: 16-3: 16-4: 16-5: 16-6: 16-7: 17-3: 17-4: 17-5: 17-6: 17-7: 18-3: 18-4: 18-5: 18-6: 18-7: 19-5: 19-4: 19-3: 19-6: 20-3: 20-4: 19-7: 20-7: 20-6: 20-5: 12:
13:
14:
15:
Material2:
16:
17:
18:
19:
20:
Material3: