Traditional Methods
ROM Plus® Rupture of Membranes Test provides reliable sensitivity1, delivered conveniently and cost effectively.
HIGH SENSITIVITY AT ALL GESTATIONAL AGES
Insert swab 5-7 cm and collect sample for 15
seconds.
QUICK AND EASY
Control LineTest Line
Control LineTest Line
2-3 in
>>
5-7cm
Control LineTest Line
Control LineTest Line
2-3 in
>>
5-7cm
Control LineTest Line
Control LineTest Line
2-3 in
>>
5-7cm
Control LineTest Line
Control LineTest Line
2-3 in
>>
5-7cm
1. Collect Sample 2. Place Swab & Mix 3. Insert Test Strip 3. Remove & Interpret
Place swab into vial and mix in buffer solution for
15 seconds.
Place ROM Plus ES strip into the vial with the
arrows down.
Remove strip if two lines are visible or after 10
minutes.
See Package Insert for Full Instructions, Warnings, Precautions & Contraindications
F E R N I N G 5
S P E C I F I C I T YS E N S I T I V I T Y
N I T R A Z I N E 5 9 0 - 9 7 % 1 6 - 7 0 %
5 1 - 9 8 % 7 0 - 8 8 %
P O O L I N G S u b j e c t i v e S u b j e c t i v e
E S P L I N , 2 0 1 9 9 3 2 4 9 1 . 7 % 9 7 %
R O M P l u s I F U 9 0 . 7 %9 9 . 5 %2 8 5
R O G E R S , 2 0 1 6 4
I G B I N O S A , 2 0 1 7 3
S P E C I F I C I T YS E N S I T I V I T YP A T I E N T S
T H O M A S I N O , 2 0 1 3 2 9 0 . 7 %9 9 . 5 %2 8 5
1 1 1 9 6 . 4 % 9 8 . 8 %
S E N A N A Y A K E , 2 0 1 3 1 9 5 9 8 . 9 % N / A
7 5 1 0 0 % 9 4 . 8 %
clinicalinnovations.com6-9 The Square, Stockley Park
Heathrow | UB11 1FW | United KingdomPhone +44 333 370 4408 | Fax +44 (0) 845 299 1517
© Clinical Innovations, LLC. All rights reserved. | ART-0013 Rev. 02
Local Distributor:
PRODUCT SUPPORT
Ordering Information
THE SCIENCE BEHIND THE TEST
1. Senanayake HM. Actim™ PROM, AmniSure®, and ROM+plus®: Rupture of membrane kits tested on amniotic fluid from women at C-section: a comparative study. Sri Lanka Journal of Obstetrics and Gynaecology. 2013; 116-121. 2. Thomasino T, Levi C, Draper M, Neubert AG. Diagnosing rupture of membranes using combination monoclonal/polyclonal immunologic protein detection. J Reprod Med. 2013;58(5–6):187–194. 3. Igbinosa, Irogue & A. Moore, Ferney & Johnson, Cheri & Block, Jon. (2017). Comparison of rapid immunoassays for rupture of fetal membranes. BMC Pregnancy and Childbirth. 17. . 10.1186/s12884-017-1311-y. 4. Rogers LC, Scott L, Block JE. Accurate point-of-care detection of ruptured fetal membranes: improved diagnostic performance characteristics with a monoclonal/polyclonal immunoassay. Clin Med Insights Reprod Health. 2016;10:15–8. 5. Caughey, et al. Rev Obstet Gynecol 2008; 1:11-22. de Haan et al., Am J Perinatol 1994; 11:46-506. Wathen et. al 19937. Rose, N. C., MD, & Mennuti, M. T., MD. Gynecology & Obstetrics (Vol. 3).8. McQuivey RW, Block JE. ROM Plus: accurate point-of-care detection of ruptured fetal membranes. Med Devices (Auckl) 2016;9:69–74.9. Esplin, et. al. Prospective evaluation of the efficacy of immunoassays in the diagnosis of rupture of the membranes. J Matern Fetal Neonatal Med. 2019 Jan 13:1-7. doi: 10.1080/14767058.2018.1555809. [Epub ahead of print]
forMOM. forBABY. forLIFE.™
This product is not currently for sale in the U.S.
Ask for additional details.
Potential savings compared to similar immunoassay tests.
MONEY BACK
GUARANTEE
Product Description Box Quantity
Test Kits- Kit w/test strip, swab, vial with solution
Product Code
ROM-1025 25/box
Quality Control- 1 Positive control & 1 Negative control ROM-QCS 5/box
Increased sensitivity in all gestational ages by detecting AFP as well as IGFBP-1.2
Increase the likelihood of detecting proteins and help avoid false negatives by using both monoclonal and
polyclonal antibodies.8
Monoclonal Antibody(One receptor site)
Polyclonal Antibodies(Multiple receptor sites)
TWO PROTEINSProtein Levels in Amniotic Fluid
TWO ANTIBODIES
30,000
20,000
10,000
1,000
10 20 30 40Gestation (weeks)
AFP μg/ml7 IGFBP-1 μg/ml6
100,000
10,000
1,000
100
10
ROM Plus uses a unique monoclonal and polyclonal antibody approach while looking for two protiens, AFP (alpha-fetoprotein) and IGFBP-1 (insulin growth factor binding protein-1),
to improve overall test sensitivity.