quick links - accu-tech · 2017-10-09 · cable, connectors, jumpers and accessories surge...

60
RF CABLES, CONNECTORS and ACCESSORIES QUICK LINKS Table of Contents Feeder Cable Connectors Accessories Technical Info Part Number Index UPDATED: March 19, 2012 SuperiorEssex.com/Comm

Upload: others

Post on 09-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

RF CABLES, CONNECTORS and ACCESSORIES

QUICK LINKSTable of ContentsFeeder CableConnectorsAccessoriesTechnical InfoPart Number Index

UPDATED: March 19, 2012

SuperiorEssex.com/Comm

Page 2: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Our Ongoing Commitment to Quality, Value and On-Time DeliverySuperior Essex is a global leader in the design, manufacture and supply of communications wire and cable products for telecommunications service providers, businesses and residences. Headquartered in Atlanta, Georgia, Superior Essex has a 55 year history of designing high performance products for the evolving technical needs of our customers, including many of the largest telecom service providers in the world. Also, we are one of the few manufacturers in North America with a product portfolio that includes a broad range of copper and fiber communications cabling products for both indoor and outdoor applications.

In 2008, Superior Essex joined the family of companies owned by LS, one of the largest manufacturing corporations in Korea, with businesses centered in the energy, communications, plastics, fabrication and automotive industries and manufacturing facilities located around the world. In 2008, our total corporate revenues exceeded $10 billion.

Now, as part of the LS corporate family, Superior Essex has added LS RF transmission products to the portfolio of communications products offered in North America. Our extensive product portfolio for wired communications systems includes a complete line of RF transmission cables, connectors and accessories for commercial wireless cell tower applications.

Page 3: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Our Experience in RF Transmission SystemsOur Company has been manufacturing and supplying RF transmission products since 1996. Currently, we are the largest supplier in Korea and one of the largest in the world. All of our RF transmission products have achieved compliance with the applicable industry standards, and all have been rigorously evaluated by some of the most demanding cellular service providers across the globe. Customers choose our RF transmission products for their ruggedness, quality, and superior performance specifications.

Our reference list of RF transmission product customers includes many of the largest cellular service providers including: Vodafone, Hutchison, Airtel, Mobile Link, Orange, SKT, KTF, KT, C-Mobile, Cellcom and many others.

Exceptional Product Quality and ServiceOur RF transmission products have many technical and quality features that make them stand out. In addition, our North American based technical support staff is ready to assist with training or product application questions. The many advantages of the Superior Essex product line are found in the following product specification pages.

Superior Essex makes every effort to ensure the accuracy of the information contained in this catalogue at the time of publication. Specifications, packaging and part numbers detailed within are subject to change. For the most up to date information, please contact Superior Essex at 770.657.6000 or visit SuperiorEssex.com/Comm. © 2012 Superior Essex, Inc.

Page 4: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Table of Contents

Feeder Cable A-1LHF Series Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . A-2LHF Series (Ultimate High Performance) Ultimate Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . A-3LHF (White Jacketed) Series Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . A-4HFAC Series Flexible Foam Dielectric Aluminum Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5HFSC Series Super Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6

Connectors B-1DIN Series for LHF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3DIN Series for HFAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4DIN Series for HFSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5N Series for LHF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6N Series for HFAC/HFSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7

Accessories C-1Jumper Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2Universal Weatherproofing Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3Hoisting Grip Lace-Up and Pre-Laced. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4Clip-On Grounding Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5Universal Snap-in Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6Stackable Snap-in Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7Standard Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8λ/4 Wave Surge Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9Gas Tube Surge Arrestor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10Cable Cutting Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-11Cushion and Boot Assembly Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-12Round Adapter Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-13Stand-Off Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-13Three-Way Stand-Off Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-14Angle Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-14Ground Buss Bar Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-15Weather Proofing Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-16Anti-Theft Hardware Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-17

Technical Info D-1Metric Measurement Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2Standard and Cut To Length Wood Reels For LHF, HFAC and HFSC Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3

Dimensional SpecificationsLHF-12D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4LHF-22D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5LHF-33D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6LHF-42D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7HFAC-22D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8HFAC-42D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8HFSC-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9DIN Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-10N Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-11

Installation GuidesConnectors for LHF-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-12Connectors for LHF-22D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-14Connectors for LHF-33D and LHF-42D Cables. . . . . . . . . . . . . . . . . . . . . D-16Connectors for HFSC-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-18

Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-20

Page 5: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Self-Supporting TowerCable, Connectors, Jumpers and Accessories

Surge Arrestors

Universal Weatherproofing Kit

Coaxial Cables

Hangers

Lace-Up Hoisting Grip

Grounding Kit: Clip-On Type

Jumper Cable

DIN Connectors

Universal Weatherproofing Kit

Jumper Cable

DIN Connectors

Cushion and Boot

Page 6: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Page 7: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Feeder Cable

Table of ContentsLHF Series Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . A-2LHF Series (Ultimate High Performance) Ultimate Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . A-3LHF (White Jacketed) Series Low Loss High Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . A-4HFAC Series Flexible Foam Dielectric Aluminum Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5HFSC Series Super Flexible Foam Dielectric Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6

Page 8: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-2 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF Series Low Loss High Flexible Foam Dielectric Feeder

Specifications

Inner Conductor Material

LHF-12D: Copper-clad aluminum wireLHF-22D: Smooth copper tubeLHF-33D: Smooth copper tubeLHF-42D: Helically corrugated copper tube

Dielectric Material Foamed polyethylene

Outer Conductor Material Annularly corrugated copper tube

Recommended Operating Temperature °F (°C) -40 ~ +185 (-40 ~ +80)

Part Numbers and Physical Characteristics

Part NumberCable Size

in (mm)

Nominal Diameterin (mm)

Minimum Bend Radius

in (mm)Approx. Weightlbs/kft (kg/km)

Flat Rate Crush Resistance

lb/in (kg/mm)

Maximum Pulling Force

lbs (kg)Inner Conductor Dielectric Outer Conductor Jacket

LHF-12D ½ (12) 0.20 (5.0) 0.49 (12.5) 0.56 (14.2) 0.65 (16.4) 4.92 (125) 163 (244) 0.16 (2.0) 249 (113)

LHF-22D ⅞ (22) 0.37 (9.4) 0.93 (23.5) 1.00 (25.3) 1.10 (28.0) 9.84 (250) 325 (485) 0.15 (1.8) 323 (147)

LHF-33D 1¼ (33) 0.54 (13.7) 1.32 (33.6) 1.43 (36.4) 1.55 (39.4) 14.96 (380) 613 (915) 0.21 (2.4) 572 (260)

LHF-42D 1⅝ (42) 0.71 (18.1) 1.71 (43.5) 1.83 (46.5) 1.97 (50.0) 19.69 (500) 716 (1,068) 0.13 (1.6) 398 (181)

Electrical Specifications

Part NumberCable Size

in (mm)

Conductor DC ResistanceOhms/km (Ohms/kft) Insulation

ResistancemΩ km

Dielectric Strength for 1 minute

DC Potential – Volts

Velocity of Propagation

%

Peak Power Rating

kW

Maximum Operating Frequency

GHz

Characteristic Impedance

Ohms

Typical Return Loss

dbInner Outer

LHF-12D ½ (12) 1.6 (0.5) 1.9 (0.6) 10,000 4,000 89 40 8.8 50 28

LHF-22D ⅞ (22) 1.5 (0.5) 1.9 (0.6) 10,000 6,000 89 91 4.9 50 ± 1 28

LHF-33D 1¼ (33) 1.1 (0.3) 1.0 (0.3) 10,000 10,000 89 200 3.3 50 ± 1 28

LHF-42D 1⅝ (42) 1.4 (0.4) 0.6 (0.2) 10,000 11,000 89 302 2.5 50 ± 1 28

FrequencyMHz

Attenuation at 20˚CdB/100 ft (dB/100 m)

Average Power Rating at Ambient 40˚C Inner Conductor 100˚C

kW

LHF-12D LHF-22D LHF-33D LHF-42D LHF-12D LHF-22D LHF-33D LHF-42D

30 0.35 (1.14) 0.18 (0.59) 0.13 (0.42) 0.10 (0.33) 6.10 13.95 21.30 30.60

100 0.65 (2.12) 0.34 (1.13) 0.24 (0.49) 0.20 (0.64) 3.32 7.36 11.50 16.42

150 0.79 (2.60) 0.43 (1.40) 0.30 (0.98) 0.24 (0.80) 2.71 5.98 9.32 13.28

450 1.40 (4.58) 0.77 (2.52) 0.54 (1.77) 0.45 (1.48) 1.55 3.32 5.23 7.37

824 1.92 (6.31) 1.07 (3.51) 0.76 (2.49) 0.64 (2.11) 1.13 2.46 3.78 5.28

894 2.00 (6.55) 1.12 (3.67) 0.80 (2.61) 0.67 (2.20) 1.09 2.36 3.61 5.05

960 2.08 (6.84) 1.16 (3.82) 0.83 (2.72) 0.70 (2.31) 1.05 2.27 3.48 4.85

1,000 2.13 (7.00) 1.19 (3.92) 0.85 (2.79) 0.73 (2.38) 1.03 2.22 3.40 4.74

1,700 2.84 (9.32) 1.61 (5.29) 1.17 (3.84) 1.00 (3.28) 0.78 1.67 2.53 3.50

1,800 2.93 (9.61) 1.67 (5.47) 1.21 (3.97) 1.04 (3.40) 0.76 1.62 2.45 3.39

2,000 3.11 (10.19) 1.77 (5.81) 1.30 (4.25) 1.11 (3.63) 0.71 1.53 2.31 3.18

2,400 3.38 (11.10) 1.97 (6.46) 1.44 (4.73) 1.23 (4.05) 0.65 1.38 2.09 2.86

2,700 3.81 (12.53) 2.10 (6.88) 1.56 (5.11) 1.27 (4.18) 0.61 1.31 1.95 2.77

3,000 3.95 (12.96) 2.25 (7.37) 1.66 (5.43) - 0.58 1.22 1.84 -

3,500 4.24 (13.92) 2.46 (8.08) - - 0.53 1.12 - -

4,000 4.65 (15.27) 2.67 (8.75) - - 0.50 1.04 - -

5,000 5.23 (17.15) 3.04 (9.99) - - 0.44 0.92 - -Standard Conditions: V.S.W.R. 1.0, Ambient Temperature 20°C/Attenuation is typical value.

Features• 100% of all RF feeder cables are inspected and tested to specification

compliance, including Passive Intermodulation• 99.95% oxygen free raw copper is used in all RF feeder coax cables• Quality testing goes beyond mechanical and electrical requirements

to include water penetration performance, fire resistance, and other environmental conditions

LHF-12D

LHF-22D

LHF-33D

LHF-42D

Page 9: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-3Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF Series (ultimate high Performance) Ultimate Low Loss High Flexible Foam Dielectric Feeder

Specifications

Inner Conductor Material LHF-22DU: Smooth copper tubeLHF-42DU: Corrugated copper tube

Dielectric Material Foamed polyethylene

Outer Conductor Material Corrugated copper tube

Recommended Operating Temperature °F (°C) -40 ~ +185 (-40 ~ +80)

Part Numbers and Physical Characteristics

Part NumberCable Size

in (mm)

Nominal Diameterin (mm)

Minimum Bend Radius

in (mm)Approx. Weightlbs/kft (kg/km)

Flat Rate Crush Resistance

lb/in (kg/mm)

Maximum Pulling Force

lbs (kg)Inner Conductor Dielectric Outer Conductor Jacket

LHF-22DU ⅞ (22) 0.37 (9.5) 0.91 (23.1) 1.00 (25.3) 1.11 (28.2) 9.84 (250) 65 (470) 0.15 (1.8) 323 (147)

LHF-42DU 1⅝ (42) 0.71 (18.1) 1.72 (43.6) 1.83 (46.6) 1.97 (50.0) 19.69 (500) 710 (1,059) 0.13 (1.6) 398 (181)

Electrical Specifications

Part NumberCable Size

in (mm)

Conductor DC ResistanceOhms/km (Ohms/kft) Insulation

ResistancemΩ km

Dielectric Strength for 1 minute

DC Potential – Volts

Velocity of Propagation

%

Peak Power Rating

kW

Maximum Operating Frequency

GHz

Characteristic Impedance

Ohms

Typical Return Loss

dbInner Outer

LHF-22DU ⅞ (22) 1.9 (0.6) 1.9 (0.6) 10,000 6,000 91 ± 3 0.92 5.0 50 ± 1 28

LHF-42DU 1⅝ (42) 1.6 (0.4) 0.7 (0.2) 10,000 11,000 92 ± 3 2.77 2.5 50 ± 1 28

FrequencyMHz

V.S.W.R.

LHF-22D LHF-42D

800 ~ 960 1.13 1.13

1,700 ~ 2,200 1.13 1.13Standard Conditions: V.S.W.R. 1.0, Ambient Temperature 20°C/Attenuation is typical value.

FrequencyMHz

Attenuation at 20˚CdB/100 ft (dB/100 m)

LHF-22D LHF-42D

450 0.73 (2.42) 0.43 (1.43)

700 0.93 (3.06) 0.55 (1.82)

824 1.02 (3.35) 0.61 (2.00)

894 1.07 (3.50) 0.64 (2.09)

960 1.11 (3.64) 0.66 (2.18)

1,700 1.52 (4.99) 0.92 (3.02)

2,000 1.66 (5.47) 1.01 (3.33)

2,400 1.85 (6.07) 1.13 (3.71)

3,000 2.10 (6.89) -

Product DescriptionThe LHF Ultimate High Performance cable series offers a higher level of performance for today’s networks.

Features/Benefits• 100% of all RF feeder cables are inspected and tested to specification

compliance, including Passive Intermodulation• 99.95% oxygen free raw copper is used in all RF feeder coax cables• Quality testing goes beyond mechanical and electrical requirements

to include water penetration performance, fire resistance, and other environmental conditions

LHF-22DU

LHF-42DU

FrequencyMHz

Average Power Rating at Ambient 40˚C Inner Conductor 100˚C

kW

LHF-22DU LHF-42DU

824 2.49 3.60

894 2.38 3.44

1,700 1.67 2.38

1,800 1.61 2.30

2,000 1.54 2.16

Page 10: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-4 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Specifications

Inner Conductor MaterialLHF-22DWH: Smooth copper tubeLHF-42DWH: Helically corrugated

copper tube

Dielectric Material Foamed polyethylene

Outer Conductor Material Annularly corrugated copper tube

Recommended Operating Temperature °F (°C) -40 ~ +185 (-40 ~ +80)

Part Numbers and Physical Characteristics

Part NumberCable Size

in (mm)

Nominal Diameterin (mm)

Minimum Bend Radius

in (mm)Approx. Weightlbs/kft (kg/km)

Flat Rate Crush Resistance

lb/in (kg/mm)

Maximum Pulling Force

(kg)Inner Conductor Dielectric Outer Conductor Jacket

LHF-22DWH ⅞ (22) 0.37 (9.4) 0.93 (23.5) 1.00 (25.3) 1.10 (28.0) 9.84 (250) 325 (485) 0.15 (1.8) 323 (147)

LHF-42DWH 1⅝ (42) 0.71 (18.1) 1.71 (43.5) 1.83 (46.5) 1.97 (50.0) 19.69 (500) 716 (1,068) 0.13 (1.6) 398 (181)

Electrical Specifications

Part NumberCable Size

in (mm)

Conductor DC ResistanceOhms/km (Ohms/kft) Insulation

ResistancemΩ km

Dielectric Strength for 1 minute

DC Potential – Volts

Velocity of Propagation

%

Peak Power Rating

kW

Maximum Operating Frequency

GHz

Characteristic Impedance

Ohms

Typical Return Loss

dbInner Outer

LHF-22DWH ⅞ (22) 1.5 (0.5) 1.9 (0.6) 10,000 6,000 89 91 4.9 50 ± 1 28

LHF-42DWH 1⅝ (42) 1.4 (0.4) 0.6 (0.2) 10,000 11,000 89 302 2.5 50 ± 1 28

FrequencyMHz

Attenuation at 20˚CdB/100 ft (dB/100 m)

Average Power Rating at Ambient 40˚C Inner Conductor 100˚C

kW

LHF-22DWH LHF-42DWH LHF-22DWH LHF-42DWH

30 0.18 (0.59) 0.10 (0.33) 13.95 30.60

100 0.34 (1.13) 0.20 (0.64) 7.36 16.42

150 0.43 (1.40) 0.24 (0.80) 5.98 13.28

450 0.77 (2.52) 0.45 (1.48) 3.32 7.37

824 1.07 (3.51) 0.64 (2.11) 2.46 5.28

894 1.12 (3.67) 0.67 (2.20) 2.36 5.05

960 1.16 (3.82) 0.70 (2.31) 2.27 4.85

1,000 1.19 (3.92) 0.73 (2.38) 2.22 4.74

1,700 1.61 (5.29) 1.00 (3.28) 1.67 3.50

1,800 1.67 (5.47) 1.04 (3.40) 1.62 3.39

2,000 1.77 (5.81) 1.11 (3.63) 1.53 3.18

2,400 1.97 (6.46) 1.23 (4.05) 1.38 2.86

2,700 2.10 (6.88) 1.27 (4.18) 1.31 2.77

3,000 2.25 (7.37) - 1.22 -

3,500 2.46 (8.08) - 1.12 -

4,000 2.67 (8.75) - 1.04 -

5,000 3.04 (9.99) - 0.92 -Standard Conditions: V.S.W.R. 1.0, Ambient Temperature 20°C/Attenuation is typical value.

Features• White polyethylene jacketing meets ASTM G 155:2005 extreme sunlight

resistant levels, up to 720 hours, without cracking our discoloring• All RF feeder cables are inspected and tested to specification

compliance, including Passive Intermodulation• 99.95% oxygen free raw copper is used in all RF feeder coax cables• Quality testing goes beyond mechanical and electrical requirements

to include water penetration performance, fire resistance, and other environmental conditions

LHF-22DWH

LHF-42DWH

LhF (White Jacketed) Series Low Loss High Flexible Foam Dielectric Feeder

Page 11: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-5Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

hFAC Series Flexible Foam Dielectric Aluminum Feeder

Features• Aluminum corrugated outer conductor design• 100% of all RF feeder cables are inspected and tested to specification

compliance, including Passive Intermodulation• Center conductor is 99.95% oxygen free raw copper• Quality testing goes beyond mechanical and electrical requirements to

include water penetration performance and other environmental conditions• Equivalent attenuation as copper cables• Cost-efficient alternative to copper cable

Specifications

Inner Conductor Material HFAC-22D: Smooth copper tubeHFAC-42D: Corrugated copper tube

Dielectric Material Closed foamed polyethylene

Outer Conductor Material Corrugated aluminum tube

Jacket Material Standard black PE

Recommended Operating Temperature °F (°C) -40 ~ +185 (-40 ~ +80)

Part Numbers and Physical Characteristics

Part NumberCable Size

in (mm)

Nominal Diameterin (mm)

Minimum Bend Radius

in (mm)Approx. Weightlbs/kft (kg/km)

Flat Plate Crush Resistance

lb/in (kg/mm)

Tensile Strengthlbs (kg)Inner Conductor Dielectric Outer Conductor Jacket

HFAC-22D ⅞ (22) 0.40 (10.2) 1.07 (27.2) 1.16 (29.5) 5 (127) 290 (432) 0.06 (1.1) 324 (146)

HFAC-42D 1⅝ (42) 0.71 (18.0) 1.87 (47.5) 1.98 (50.3) 11 (279) 670 (008) 0.06 (1.1) 405 (182)

Electrical Specifications

Part NumberCable Size

in (mm)

Conductor DC ResistanceOhms/kft Insulation

ResistancemΩ km

Dielectric Strength for 1 minute

DC Potential – Volts

Velocity of Propagation

%

Peak Power Rating

kW

Maximum Operating Frequency

GHz

Characteristic Impedance

Ohms

Jacket Spark Test

Volts RMSInner Outer

HFAC-22D ⅞ (22) 0.63 0.49 5,000 6,000 87 85 5.0 50 ± 1 8,000

HFAC-42D 1⅝ (42) 0.43 0.17 5,000 9,000 87 310 2.7 50 ± 1 10,000

FrequencyMHz

Attenuation at 20˚CdB/100 ft (dB/100 m)

Average Power Rating at Ambient 40˚C Inner Conductor 100˚C

kW

HFAC-22D HFAC-42D HFAC-22D HFAC-42D

824 1.21 (3.97) 0.71 (2.32) 2.44 5.26

894 1.26 (4.15) 0.74 (2.43) 2.33 5.02

1700 1.79 (5.87) 1.08 (3.55) 1.63 3.41

1800 1.84 (6.05) 1.10 (3.62) 1.57 3.29

1900 1.90 (6.23) 1.14 (3.74) 1.54 3.17

2000 1.96 (6.41) 1.18 (3.85) 1.48 3.08

2100 2.01 (6.58) 1.21 (3.96) 1.44 2.99

FrequencyMHz

V.S.W.R. at 20˚C

HFAC-22D HFAC-42D

800 to 1000 1.2 1.2

1700 to 2200 1.2 1.2

HFAC-22D

HFAC-42D

Page 12: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

A-6

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 3/12 Ed 2.4

hFSC Series Super Flexible Foam Dielectric Feeder

SpecificationsInner Conductor Material Copper-clad aluminum wire

Dielectric Material Foamed polyethylene

Outer Conductor Material Helically corrugated copper tube

Recommended Operating Temperature °F (°C) -40 ~ +185 (-40 ~ +80)

Part Numbers and Physical Characteristics

Part NumberCable Size

in (mm)

Nominal Diameterin (mm)

Minimum Bend Radius

in (mm)Approx. Weightlbs/kft (kg/km)

Flat Rate Crush Resistance

lb/in (kg/mm)

Maximum Pulling Force

lbs (kg)Inner Conductor Dielectric Outer Conductor Jacket

HFSC-12D ½ (12) 0.14 (3.6) 0.35 (8.9) 0.48 (12.2) 0.54 (13.6) 1.26 (32) 135 (201) 0.10 (1.7) 143 (65)

Electrical Specifications

Part NumberCable Size

in (mm)

Conductor DC ResistanceOhms/km (Ohms/kft) Insulation

ResistancemΩ km

Dielectric Strength for 1 minute

DC Potential – Volts

Velocity of Propagation

%

Peak Power Rating

kW

Maximum Operating Frequency

GHz

Characteristic Impedance

Ohms

Typical Return Loss

dbInner Outer

HFSC-12D ½ (12) 2.85 (0.87) 3.25 (0.99) 10,000 2,500 81 15.6 10.0 50 28

FrequencyMHz

Attenuation at 20˚CdB/100 ft (dB/100 m)

Average Power Rating at Ambient 40˚C Inner

Conductor 100˚CkW

30 0.55 (1.80) 4.87

100 1.01 (3.33) 2.62

150 1.25 (4.10) 2.12

450 2.22 (7.29) 1.19

824 3.08 (10.10) 0.85

894 3.20 (10.50) 0.82

960 3.35 (11.00) 0.79

1,000 3.41 (11.20) 0.77

1,700 4.57 (15.00) 0.57

1,800 4.72 (15.50) 0.55

2,000 5.00 (16.40) 0.52

2,400 5.55 (18.20) 0.47

3,000 6.31 (20.70) 0.41

4,000 7.44 (24.40) 0.35

6,000 9.45 (31.00) 0.27

10,000 12.89 (42.30) 0.20Standard Conditions: V.S.W.R. 1.0, Ambient Temperature 20°C/Attenuation is typical value.

Features• Super flexible for jumper and extremely small bending applications• 100% of all RF feeder cables are inspected and tested to specification

compliance, including Passive Intermodulation• 99.95% oxygen free raw copper is used in all RF feeder coax cables• Quality testing goes beyond mechanical and electrical requirements

to include water penetration performance, fire resistance, and other environmental conditions

HFSC-12D

Page 13: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Page 14: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Page 15: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Connectors

Table of ContentsDIN Series for LHF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3DIN Series for HFAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4DIN Series for HFSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5N Series for LHF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6N Series for HFAC/HFSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7

Page 16: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-2 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Explanation of Connector Series Part Numbers

CLH-12DFR

Product Category Compatible Cable Type Compatible Cable Size Connector Series Type Gender and Straight/Angle

C = Connector LH = Low Loss High Flexible RF FeederHFS = Super Flexible Foam DielectricHFA = Flexible Foam Aluminum Feeder

12 = ½ inch (12 mm)22 = ⅞ inch (22 mm)33 = 1¼ inch (33 mm)42 = 1⅝ inch (42 mm)

D = DIN SeriesN = N Series

F = Female, StraightFR = Female, Right AngleM = Male, StraightMR = Male, Right Angle

Connector SeriesOffering Exceptional Quality

Material and Design AdvantagesThe advantage begins with the connector material choice. Superior Essex connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. For example:

• Copper is a very good conductor and has good thermal characteristics.

• Tin has good corrosion prevention.• Zinc has a polished silver appearance.

This alloy combination also allows a better operating temperature range and improved environmental performance.

• The connector is substantially thicker than typical connectors.• A unique inner spring design improves receptivity and repeatability

of the connection.• Connector halves are tightened by fine precision threads that create

a stable precision connection.• Wrench interface positions are large and conveniently positioned

every 90 degrees.• Precision O-rings and a tube of grease are provided

with each connector.

Installation Advantages• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Page 17: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-3Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

dIN Series for LhF

Specifications

Bodies, Cap (Coupling Nut) Material Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Back Nut Material Brass/nickel plated

Pin Material

Male: Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Female: Beryllium - copper/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Insulator Material Plated PTFE (Teflon®)

Gasket Material Silicon rubber

Recommended Coupling Nut Torque Nm 25 ~ 30

Coupling Nut Retention Force Nm 1,000

Contact Captivation N 200

Mating Durability 500 times

Part Numbers and Physical Characteristics

Part Number

DIN Interface Type Compatible Cable Sizein (mm)

Lengthin (mm)

Diameterin (mm)

Weightoz (g)Gender Straight or Angle

CLH-12DF Female Straight ½ (12) 2.65 (67.4) 0.86 (21.8) 5.3 (150)

CLH-12DFR Female Right Angle ½ (12) - - -

CLH-12DM Male Straight ½ (12) 2.57 (65.4) 0.86 (21.8) 6.5 (183)

CLH-12DMR Male Right Angle ½ (12) - - -

CLH-22DF Female Straight ⅞ (22) 2.62 (66.5) 1.39 (35.2) 7.4 (210)

CLH-22DM Male Straight ⅞ (22) 2.81 (71.5) 1.39 (35.2) 8.1 (230)

CLH-33DF Female Straight 1¼ (33) 3.50 (88.9) 1.87 (47.6) 19.8 (560)

CLH-33DM Male Straight 1¼ (33) 3.76 (95.4) 1.87 (47.6) 19.8 (560)

CLH-42DF Female Straight 1⅝ (42) 3.92 (99.5) 2.35 (59.6) 35.3 (1,000)

CLH-42DM Male Straight 1⅝ (42) 4.21 (107.0) 2.35 (59.6) 37.7 (1,070)

½ inch (12 mm)

1¼ inch (33 mm)

⅞ inch (22 mm)

1⅝ inch (42 mm)

Product DescriptionThis DIN Series is compatible with the LHF Feeder Series. The connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. This alloy combination also allows a better operating temperature range and improved environmental performance.

Features/Benefits• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Electrical SpecificationsImpedance Ω 50

Maximum Frequency Range GHz 7.5

V.S.W.R. (Mating)straight (right angle)

1 GHz: 1.08 (1.12)2 GHz: 1.10 (1.15)

Maximum Insertion Loss dB @ 3 GHz 0.2

IMD dBc -155

Dielectric Withstanding VoltagekV rms @ 50 Hz 4.0

Working Voltage kV rms @ 50 Hz 2.7

Insulation Resistance GΩ 10

Contact Resistance mΩ Inner: 0.4Outer: 1.5

Environmental SpecificationsTemperature Range °F (°C) -85 ~ +329 (-65 ~ +165)

Corrosion (Salt Spray Test) IEC-68-2-11-Ka

Vibration CECC 22000 Part 4.6.3

Waterproof IP68

Page 18: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-4 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

dIN Series for hFAC

Specifications

Bodies, Cap (Coupling Nut) Material Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Back Nut Material Brass/nickel plated

Pin Material

Male: Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Female: Beryllium - copper/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Insulator Material Plated PTFE (Teflon®)

Gasket Material Silicon rubber

Recommended Coupling Nut Torque Nm 25 ~ 30

Coupling Nut Retention Force Nm 1,000

Contact Captivation N 200

Mating Durability 500 times

Electrical SpecificationsImpedance Ω 50

Maximum Frequency Range GHz 7.5

V.S.W.R. (Mating)straight (right angle)

1 GHz: 1.08 (1.12)2 GHz: 1.10 (1.15)

Maximum Insertion LossdB @ 3 GHz 0.2

IMD dBc -155

Dielectric Withstanding VoltagekV rms @ 50 Hz 4.0

Working VoltagekV rms @ 50 Hz 2.7

Insulation Resistance GΩ 10

Contact Resistance mΩ Inner: 0.4Outer: 1.5

Part Numbers and Physical Characteristics

Part Number

DIN Interface Type Compatible Cable Sizein (mm)

Lengthin (mm)

Diameterin (mm)

Weightoz (g)Gender Straight or Angle

CHFA-22DF Female Straight ⅞ (22) 2.62 (66.5) 1.39 (35.2) 7.4 (210)

CHFA-22DM Male Straight ⅞ (22) 2.81 (71.5) 1.39 (35.2) 8.1 (230)

CHFA-42DF Female Straight 1⅝ (42) 3.92 (99.5) 2.35 (59.6) 35.3 (1,000)

CHFA-42DM Male Straight 1⅝ (42) 4.21 (107.0) 2.35 (59.6) 37.7 (1,070)

⅞ inch (22 mm) 1⅝ inch (42 mm)

Product DescriptionThis DIN Series is compatible with the HFAC Feeder Series. The connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. This alloy combination also allows a better operating temperature range and improved environmental performance.

Features/Benefits• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Environmental SpecificationsTemperature Range °F (°C) -85 ~ +329 (-65 ~ +165)

Corrosion (Salt Spray Test) IEC-68-2-11-Ka

Vibration CECC 22000 Part 4.6.3

Waterproof IP68

Page 19: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-5Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

dIN Series for hFSC

Specifications

Bodies, Cap (Coupling Nut) Material Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Back Nut Material Brass/nickel plated

Pin Material

Male: Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Female: Beryllium - copper/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Insulator Material Plated PTFE (Teflon®)

Gasket Material Silicon rubber

Recommended Coupling Nut Torque Nm 25 ~ 30

Coupling Nut Retention Force Nm 1,000

Contact Captivation N 200

Mating Durability 500 times

Electrical SpecificationsImpedance Ω 50

Maximum Frequency Range GHz 7.5

V.S.W.R. (Mating)straight (right angle)

1 GHz: 1.08 (1.12)2 GHz: 1.10 (1.15)

Maximum Insertion Loss dB @ 3 GHz 0.2

IMD dBc -155

Dielectric Withstanding VoltagekV rms @ 50 Hz 4.0

Working Voltage kV rms @ 50 Hz 2.7

Insulation Resistance GΩ 10

Contact Resistance mΩ Inner: 0.4Outer: 1.5

Part Numbers and Physical Characteristics

Part Number

DIN Interface Type Compatible Cable Sizein (mm)

Lengthin (mm)

Diameterin (mm)

Weightoz (g)Gender Straight or Angle

CHFS-12DF Female Straight ½ (12) 2.65 (67.4) 0.86 (21.8) 5.3 (150)

CHFS-12DFR Female Right Angle ½ (12) - - -

CHFS-12DM Male Straight ½ (12) 2.57 (65.4) 0.86 (21.8) 6.5 (183)

CHFS-12DMR Male Right Angle ½ (12) - - -

½ inch (12 mm)

Product DescriptionThis DIN Series is compatible with the HFSC Feeder Series. The connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. This alloy combination also allows a better operating temperature range and improved environmental performance.

Features/Benefits• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Environmental SpecificationsTemperature Range °F (°C) -85 ~ +329 (-65 ~ +165)

Corrosion (Salt Spray Test) IEC-68-2-11-Ka

Vibration CECC 22000 Part 4.6.3

Waterproof IP68

Page 20: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-6 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

N Series for LhF

Product DescriptionThis N Series is compatible with the LHF Feeder Series. The connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. This alloy combination also allows a better operating temperature range and improved environmental performance.

Features/Benefits• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Specifications

Bodies, Cap (Coupling Nut) Material Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Back Nut Material Brass/nickel plated

Pin Material

Male: Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Female: Beryllium - copper/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Insulator Material Plated PTFE (Teflon®)

Gasket Material Silicon rubber

Recommended Coupling Nut Torque Nm 25 ~ 30

Coupling Nut Retention Force Nm 1,000

Contact Captivation N 200

Mating Durability 500 times

Part Numbers and Physical Characteristics

Part Number

N Interface Type Compatible Cable Sizein (mm)

Lengthin (mm)

Diameterin (mm)

Weightoz (g)Gender Straight or Angle

CLH-12NF Female Straight ½ (12) 2.75 (69.8) 0.86 (21.8) 4.1 (115)

CLH-12NFR Female Right Angle ½ (12) - - -

CLH-12NM Male Straight ½ (12) 2.75 (69.8) 0.86 (21.8) 4.2 (120)

CLH-12NMR Male Right Angle ½ (12) - - -

CLH-22NF Female Straight ⅞ (22) 2.75 (69.9) 1.39 (35.2) 7.6 (215)

CLH-22NM Male Straight ⅞ (22) 2.86 (72.7) 1.39 (35.2) 7.6 (215)

CLH-33NF Female Straight 1¼ (33) 3.76 (95.5) 1.87 (47.6) 19.8 (560)

CLH-33NM Male Straight 1¼ (33) 3.86 (98.0) 1.87 (47.6) 19.8 (560)

CLH-42NF Female Straight 1⅝ (42) 41.3 (105.0) 2.35 (59.6) 35.3 (1,000)

CLH-42NM Male Straight 1⅝ (42) 4.25 (108.0) 2.35 (59.6) 37.7 (1,070)

Electrical SpecificationsImpedance Ω 50

Maximum Frequency Range GHz 7.5

V.S.W.R. (Mating)straight (right angle)

1 GHz: 1.08 (1.12)2 GHz: 1.10 (1.15)

Maximum Insertion Loss dB @ 3 GHz 0.2

IMD dBc -155

Dielectric Withstanding VoltagekV rms @ 50 Hz 4.0

Working Voltage kV rms @ 50 Hz 2.7

Insulation Resistance GΩ 10

Contact Resistance mΩ Inner: 0.4Outer: 1.5

Environmental SpecificationsTemperature Range °F (°C) -85 ~ +329 (-65 ~ +165)

Corrosion (Salt Spray Test) IEC-68-2-11-Ka

Vibration CECC 22000 Part 4.6.3

Waterproof IP68

½ inch (12 mm)

1¼ inch (33 mm)

⅞ inch (22 mm)

1⅝ inch (42 mm)

Page 21: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

B-7Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

N Series for hFAC/hFSC

½ inch (12 mm)

Specifications

Bodies, Cap (Coupling Nut) Material Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Back Nut Material Brass/nickel plated

Pin Material

Male: Brass/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Female: Beryllium - copper/silver plated or Su Co (Alloy of Cu/Sn/Zn) plated

Insulator Material Plated PTFE (Teflon®)

Gasket Material Silicon rubber

Recommended Coupling Nut Torque Nm 25 ~ 30

Coupling Nut Retention Force Nm 1,000

Contact Captivation N 200

Mating Durability 500 times

Electrical SpecificationsImpedance Ω 50

Maximum Frequency Range GHz 7.5

V.S.W.R. (Mating)straight (right angle)

1 GHz: 1.08 (1.12)2 GHz: 1.10 (1.15)

Maximum Insertion Loss dB @ 3 GHz 0.2

IMD dBc -155

Dielectric Withstanding VoltagekV rms @ 50 Hz 4.0

Working Voltage kV rms @ 50 Hz 2.7

Insulation Resistance GΩ 10

Contact Resistance mΩ Inner: 0.4Outer: 1.5

Part Numbers and Physical Characteristics

Part Number

N Interface Type Compatible Cable Sizein (mm)

Lengthin (mm)

Diameterin (mm)

Weightoz (g)Gender Straight or Angle

CHFS-12NF Female Straight ½ (12) 2.75 (69.8) 0.86 (21.8) 4.1 (115)

CHFS-12NFR Female Right Angle ½ (12) - - -

CHFS-12NM Male Straight ½ (12) 2.75 (69.8) 0.86 (21.8) 4.2 (120)

CHFS-12NMR Male Right Angle ½ (12) - - -

Product DescriptionThis N Series is compatible with the HFAC and HFSC Feeder Series. The connectors are manufactured from an alloy material of copper, tin and zinc. These three materials produce a highly polished, precise, strong connector. Alloys have the ability to take the best attribute from each element and combine them into one great material. This alloy combination also allows a better operating temperature range and improved environmental performance.

Features/Benefits• Two-piece design is the industry standard• Simple 6-step user friendly installation process• Four ordinary tools needed; available in a common installars tool bag• If something goes wrong, the connector can be disasembled and re-used• Offers stable connections

Environmental SpecificationsTemperature Range °F (°C) -85 ~ +329 (-65 ~ +165)

Corrosion (Salt Spray Test) IEC-68-2-11-Ka

Vibration CECC 22000 Part 4.6.3

Waterproof IP68

Page 22: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Page 23: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Accessories

Table of ContentsJumper Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2Universal Weatherproofing Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3Hoisting Grip Lace-Up and Pre-Laced. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4Clip-On Grounding Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5Universal Snap-in Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6Stackable Snap-in Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7Standard Hanger Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8λ/4 Wave Surge Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9Gas Tube Surge Arrestor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10Cable Cutting Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-11Cushion and Boot Assembly Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-12Round Adapter Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-13Stand-Off Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-13Three-Way Stand-Off Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-14Angle Adapter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-14Ground Buss Bar Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-15Weather Proofing Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-16Anti-Theft Hardware Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-17

Page 24: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-2 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Jumper Cable

SpecificationsCompatible Cable Type HFSC-12D

Compatible Cable Sizein (mm) ½ (12)

Minimum Bending Radiusin (mm) 1.38 (35)

Typical V.S.W.R. 1.08 over Cellular, PCS and 3G-band

Typical IM3 Product Value with 40 dBm (dBc) 155 over the Cellular and PCS Band

Part Numbers and Physical Characteristics

Part Number

Interface Type Standard Lengthft (m) Unit of MeasureEnd 1 End 2

J12-1DMDM DIN Male, Straight DIN Male, Straight 3.3 (1) Each

J12-1NMNM N Male, Straight N Male, Straight 3.3 (1) Each

J12-2DMDM DIN Male, Straight DIN Male, Straight 6.6 (2) Each

J12-2NMNM N Male, Straight N Male, Straight 6.6 (2) Each

J12-3DMDM DIN Male, Straight DIN Male, Straight 9.8 (3) Each

J12-3NMNM N Male, Straight N Male, Straight 9.8 (3) Each

J12-3NMNMR N Male, Straight N Male, Right Angle 9.8 (3) Each

J12-4DMDM DIN Male, Straight DIN Male, Straight 13.1 (4) Each

J12-4NMNM N Male, Straight N Male, Straight 13.1 (4) Each

J12-5DMDM DIN Male, Straight DIN Male, Straight 16.4 (5) Each

J12-5DMDF DIN Male, Straight DIN Female, Straight 16.4 (5) Each

J12-5NMNM N Male, Straight N Male, Straight 16.4 (5) Each

J12-6NMNMR N Male, Straight N Male, Right Angle 19.7 (6) Each

Explanation of Part Numbers

J12-2DMDMR

Product Category Compatible Cable Size Jumper Length Connector for End 1 Connector for End 2

J = Jumper Cable 12 = ½ inch (12 mm) 1 = 1 meter2 = 2 meters3 = 3 meters4 = 4 meters5 = 5 meters6 = 6 meters

DM = DIN Male straightDMR = DIN Male Right angleDF = DIN Female straightDFR = DIN Female Right angleNM = N Male straightNMR = N Male Right angleNF = N FemaleNFR = N Female Right angle

DM = DIN Male straightDMR = DIN Male Right angleDF = DIN Female straightDFR = DIN Female Right angleNM = N Male straightNMR = N Male Right angleNF = N FemaleNFR = N Female Right angle

Product DescriptionJumper cables offer outstanding electrical performance along with high durability for tight routing and superior environmental sealing for long life reliability.

Available in ⅜ and ½ inch diameters, jumper cables are used in areas that require extremely small bending radius such as between main feeders and antennas or between main feeders and RF equipment. Jumper cables are designed and produced to have features as below.

Features/Benefits• High pull-off strength• Excellent V.S.W.R. performance• Low and Stable Intermodulation• Weatherproof

Page 25: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-3

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/CommRev 10/10 Ed 2.2

universal Weatherproofing Kit

SpecificationsMaterial Butyl and winyl tape

Each Kit Includes

• Five (5) rolls of butyl mastic tape 3.75 inches x 2 feet (95 mm x 0.6 m)

• Two (2) rolls of electrical tape 0.75 inch x 44 feet (19 mm x 13 m)

• One (1) roll of electrical tape 2 inch x 20 feet (51 mm x 6 m)

• One (1) installation instruction sheet

Part Numbers and Physical Characteristics

Part NumberWeightlbs (kg) Unit of Measure

L-WK-U 3.4 (1.5) Kit

Product DescriptionUniversal weatherproofing kits include mastic and electrical tapes to provide a multi-layer, long-term environmental seal over multiple connections.

Application• Coax protection

Features/Benefits• Multi-connection protection• Tape kit for multi-layer wrap

Page 26: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-4

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 5/11 Ed 2.2

hoisting Grip Lace-Up and Pre-Laced

SpecificationsCompatible Cable Type Corrugated coax

Compatible Cable Sizein (mm) Fits ½ (12) to 1⅝ (42) corrugated coax

Material Tinned bronze

Each Includes• One (1) mesh grip• One (1) self-locking clip• Installation instructions

Part Numbers and Physical Characteristics

Part Number Hoisting Grip ModelCompatible Cable Size

in (mm)Weight lbs (kg) Unit of Measure

L-HG-12 Lace-Up ½ (12) 0.3 (0.1) Each

L-HG-22 Lace-Up ⅞ (22) 0.6 (0.3) Each

L-HG-33 Lace-Up 1¼ (33) 0.6 (0.3) Each

L-HG-42 Lace-Up 1⅝ (42) 1.3 (0.6) Each

L-HG-12L Pre-Laced ½ (12) 0.4 (0.2) Each

L-HG-22L Pre-Laced ⅞ (22) 0.5 (0.2) Each

L-HG-33L Pre-Laced 1¼ (33) 0.5 (0.2) Each

L-HG-42L Pre-Laced 1⅝ (42) 0.5 (0.2) Each

Product DescriptionHoisting grips provide an effective means for hoisting coax and elliptical waveguide into position and can be used to provide additional support once in place. The lace-up design allows the hoisting grip to be attached even when the run has been connectorized and facilitates easy positioning at 200 feet (61 m) increments on long coax runs.

Pre-laced hoisting grips feature a closed-mesh design which simplifies installation over traditional split, lace-up style grips. The unique design allows the pre-laced hoisting grip to slip over an unterminated end of coax. The grip securely tightens when pulled, providing an effective means to hoist coax into position and to provide additional support for the coax once in place.

Hoisting grip kits include a self-locking clip and sealing tape to provide additional support both during and after installation.

Application• Coax• Coax support

Features/Benefits• Lace-up installation at any point on coax• Pre-laced to simplify installation• Mesh grip with single eye support

Page 27: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-5

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/CommRev 10/10 Ed 2.2

Clip-On Grounding Kit

SpecificationsCompatible Cable Type Corrugated coax

Compatible Cable Sizein (mm) Fits ½ (12) to 1⅝ (42)

Mounts to Coax outer conductor

Material Copper strap

Each Kit Includes

• One (1) 6-guage, 7-strand copper ground lead measuring 4.92 feet (1.5 m) long

• One (1) roll of electrical tape 2 inch x 20 feet (51 mm x 6 m)

• One (1) roll of butyl mastic tape 3.75 inch x 2 feet (95 mm x 0.6 m)

• Necessary hardware for ground bar attachment• One (1) 2-hole universal lug compatible with

½ inch (12 mm) coax

Part Numbers and Physical Characteristics

Part NumberCompatible Cable Size

in (mm)Weightlbs (kg) Unit of Measure

L-GK-C12 ½ (12) 1.4 (0.6) Kit

L-GK-C22 ⅞ (22) 1.4 (0.6) Kit

L-GK-C33 1¼ (33) 1.4 (0.6) Kit

L-GK-C42 1⅝ (42) 1.5 (0.7) Kit* Note: 0.375 inch (10 mm) two-hole lugs are universal to accommodate 0.75 inch to 1 inch (19 mm to 25 mm) spacing requirements. Versions of these kits are available with 0.25 inch (6 mm) two-hole lugs or with your choice of lug pre-attached.

Product DescriptionClip-on ground kits, as part of an advanced coax grounding solution, provide the ultimate in ease-of-installation coupled with dependable protection of your coaxial cable system. The unique clip design and pre-formed strap allows the clip-on ground kits to slip easily over the outer conductor of the coax and firmly latched into place. The latch mechanism has been optimized to provide a secure fit maximizing performance by ensuring proper contact surface area and pressure. The innovative design of the clip-on ground kits greatly simplifies installation, minimizes installation time over traditional coiled and bolt-on grounding kits. This design also eliminates the danger of overtightening which reduces the chance of costly errors in the field. The clip-on ground kits are designed to comply with MIL-STD-188-124A, protecting coax from the damaging effects of lightning current in excess of 200 kA. Each kit includes a 6-gauge 7-strand copper ground lead. All buss bar attachment hardware is included along with required mastic and electric tape for weatherproofing each kit.

Application• Coax protection

Features/Benefits• Easy-to-install clip design• One-piece style with three lead/lug options

Page 28: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-6 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

SpecificationsCompatible Cable Type Corrugated coax

Compatible Cable Sizein (mm) ½ (12) to 2¼ (58)

Mounts toin (mm) ¾ (19) holes

Material Stainless steel

Each Kit Includes • 10 appropriately sized snap-in hangers• One (1) installation instruction sheet

Not Included (Order Separately) Brackets

Part Numbers and Physical Characteristics

Part NumberCompatible Cable Size

in (mm)Weightlbs (kg) Unit of Measure

L-SH-U12 ½ (12) 0.7 (0.3) Kit

L-SH-U22 ⅞ (22) 1.2 (0.5) Kit

L-SH-U33 1¼ (33) 1.3 (0.6) Kit

L-SH-U42 1⅝ (42) 1.5 (0.7) Kit

universal Snap-in hanger Kit

Product DescriptionThe next-generation Universal Snap-in Hangers incorporate numerous innovative design features which ensure secure, dependable support and simplified installation for your coaxial cable system. The unique internal coax fingers securely grip the coax, yet float freely within the hanger to ensure flexibility during installation. The tension and thickness of steel has been optimized to minimize stiffness and allow easy insertion into a ¾ inch (19 mm) mounting hole. The advanced snap-in fingers are specifically designed to eliminate inadvert pop-out. The unique curved finger-tips provide a powerful barrier to pop-out and offer additional security when faced with excessive galvanizing or rounded edges. The Universal Snap-in Hangers internal ribbing and dog-eared internal fingers provide a firm grip to resist coax slippage. The stainless steel construction guarantees exceptional integrity in highly corrosive environments and extreme weather conditions.

Application• Coax support

Features Benefits• One-piece hanger solution • Simplified coax installation

Page 29: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-7

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/CommRev 8/11 Ed 2.2

SpecificationsCompatible Cable Type Corrugated coax

Compatible Cable Sizein (mm) ⅜ (9.5) to 1⅝ (42)

Material Stainless steel

Each Kit Includes• 10 appropriately sized stackable

snap-in hangers• One (1) installation instruction sheet

Not Included (Order Separately) Brackets

Part Numbers and Physical Characteristics

Part NumberCompatible Cable Size

in (mm) Stack HeightWeightlbs (kg) Unit of Measure

SSHAK3812* ⅜ (9.5) 3 Runs 3.1 (1.4) Kit

L-SH-S12 ½ (12) 3 Runs 0.7 (0.3) Kit

L-SH-S22 ⅞ (22) 3 Runs 1.2 (0.5) Kit

L-SH-S33 1¼ (33) 2 Runs 1.3 (0.6) Kit

L-SH-S42 1⅝ (42) 2 Runs 1.5 (0.7) Kit*Includes grommet.

Product DescriptionThe self contained design of the Stackable Snap-in Hanger eliminates the need for mounting hardware while providing a compact solution for supporting coaxial cable. The hanger can be stacked up to three runs high when using ⅜”, ½” and ⅞” coaxial cable, or two runs high when using 1¼” and 1⅝” coaxial cable.

Each hanger accommodates one run of coaxial cable. The advanced design of the retention tabs gives the hanger the ability to absorb vibration, making the hanger resistant to pop-out. This unique design also reduces movement in the runs of coaxial cable, therefore reducing stress on the connections. They are manufactured from stainless steel, ensuring long term integrity over the life of the product in extreme environments including mountain tops, coastal and industrial applications.

Application• Coax support

Features Benefits• One-piece hanger solution • Eliminates the need for

mounting hardware for a simplified coax installation

Stackable Snap-in hanger Kit

Page 30: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-8 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Standard hanger Kit

SpecificationsCompatible Cable Type Corrugated coax

Compatible Cable Sizein (mm) Fits ½ (12) to 1⅝ (42)

Mounts toin (mm) ⅜ (9.5) hardware

Material Stainless steel

Each Kit Includes

• 10 appropriately sized stainless steel hangers without hardware

• 10 captive ¼ inch (6.4 mm) slotted hex head bolts

• One (1) installation instruction sheet

Not Included (Order Separately) Brackets

Part Numbers and Physical Characteristics

Part NumberCompatible Cable Size

in (mm)Weightlbs (kg) Unit of Measure

LBHS12NH ½ (12) 0.8 (0.4) Kit

LBHS22NH ⅞ (22) 1.1 (0.5) Kit

LBHS33NH 1¼ (33) 1.3 (0.6) Kit

LBHS42NH 1⅝ (42) 1.8 (0.8) Kit

Product DescriptionThe Standard Hangers provide a dependable solution for supporting single runs of coaxial cable in wireless systems. The pre-formed design greatly simplifies installation, allowing the coax to be quickly slipped into the Standard Hanger and then secured using the included captivated bolt. Corrosion resistant stainless steel construction ensures long term integrity in weather extreme applications. Integrated cable grippers bite into the coax jacketing providing additional support in heavy wind and ice loading conditions.

Application• Coax support

Features Benefits• Pre-formed bolt-on single

run hanger• Reduces installation time

Page 31: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-9

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/CommRev 11/10 Ed 2.2

λ/4 Wave Surge Arrestor

SpecificationsOuter Conductor Material Brass/silver or Su Co plated

Inner Conductor Material Be Cu (Female)/silver or Su Co plated

Other Metal Parts Materials Brass/nickel plated

Temperature Range °C -40 ~ +100

Moisture Resistance Waterproof

Frequency Band MHz 700 ~ 2,700

Electrical SpecificationsImpedance (Nominal) Ω 50

V.S.W.R. < 1.1

Insertion Loss dB < 0.1

IMD dBc -155

Max. Impulse Spark-Over Voltage > 600

Part Numbers and Physical Characteristics

Part Number Surge Arrestor ModelFrequency Band

MHz Interface Type Unit of Measure

ATNMNF700 λ/4 wave 700 ~ 2,700 N Male/N Female Each

ATDMDF700 λ/4 wave 700 ~ 2,700 DIN Male/DIN Female Each

AT-NMNF-W λ/4 wave 800 ~ 2,700 N Male/N Female Each

AT-DMDF-W λ/4 wave 800 ~ 2,700 DIN Male/DIN Female Each

Product DescriptionSurge arrestors provide excellent lightning protection and outstanding RF performance. All designs have low return loss, low insertion loss and low intermodulation.

Features/Benefits• Outstanding RF performance• Completely weatherproof• Available with Type N or DIN interface• Maintenance free operation (λ/4 wave shorting stubs)

Page 32: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-10 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Product DescriptionA surge arrestor is a gas discharge tube type for lightning strike protection, used most widely with λ/4 stub type systems. The surge arrestor allows for replaceable gas discharge tubes between internal and outer conductor. When activated, this unit discharges electron pulse energy instantaneously to earth.

Features/Benefits• Outstanding Broadband RF performance (DC~2400 MHz)• DC pass capability• High tensional internal conductor structure• Waterproof• Available with 0.4375 in (11.1 mm) DIN type

Gas Tube Surge Arrestor

SpecificationsOuter Conductor Material Brass / Silver or Su Co Plated

Inner Conductor Material Be Cu (Female) / Silver or Su Co Plated

Other Metal Parts Materials Brass / Nickel Plated

Temperature Range °C -40 ~ +100

Moisture Resistance Waterproof

Frequency Band MHz DC ~2,700

Electrical SpecificationsImpedance (Nominal) Ω 50

V.S.W.R. < 1.1

Insertion Loss dB < 0.1

Max. Impulse Spark-Over Voltage > 600

Part Numbers and Physical Characteristics

Part Number Surge Arrestor Model Interface Type Unit of Measure

AGDMDF02 Gas Tube DIN Male/DIN Female Each

AG-NFNF Gas Tube N Female/N Female Each

Page 33: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-11Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Cable Cutting Tool

Part Numbers and Physical Characteristics

Part Number DescriptionCompatible Cable Size

in (mm) Compatible Cable Type Unit of Measure

L-CT-12D Jacket and Outer Conductor Cutting Tool ½ (12) Flexible Feeder Each

L-CT-22D Jacket, Outer Conductor, Dielectric and Inner Conductor Cutting Tool ⅞ (22) Flexible Feeder Each

L-FT-42D* T-flaring Cutting Tool 1⅝ (42) Flexible Feeder Each*Not pictured

Product DescriptionConnector termination is one of the most important factors affecting Radio Frequency (RF) transmission line operation. Cable cutting tools are offered in sizes ranging from ½ to 1⅝ inches (12 to 42 mm). These precision tools are designed to cut the jacket and outer conductor quickly and easily.

Cutting tools make accurate cuts in the cable at exact distance requirements for easy connector assembly.

Features/Benefits• Accurate termination• Easy handling

Page 34: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-12

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 10/10 Ed 2.2

Cushion and Boot Assembly Kit

SpecificationsSize Versions for coax and elliptical waveguide

Design Compression boot kit for aluminum entry panels

Mounts to 4 inch (102 mm) entry panels

Material EPDM rubber

Each Kit Includes

• One (1), 4 inch (101.6 mm) pre-molded grooved boot

• One (1) cushion insert with appropriately sized hole(s) for corrugated coax or flexible coax

• One (1), #80 round member hose clamp• One (1), #64 round member hose clamp• One (1) installation instruction sheet

Not Included (Order Separately) 4 inch (102 mm) entry panel

Part Numbers and Physical Characteristics

Part NumberCompatible Cable Size

in (mm) Compatible Cable Type Number of HolesWeightlbs (kg) Unit of Measure

LBA-12-1A ½ (12) Corrugated Coax 1 1.6 (0.7) Kit

LBA-12-2A ½ (12) Corrugated Coax 2 1.6 (0.7) Kit

LBA-12-3A ½ (12) Corrugated Coax 3 1.6 (0.7) Kit

LBA-12-4A ½ (12) Corrugated Coax 4 1.6 (0.7) Kit

LBA-12-5A ½ (12) Corrugated Coax 5 1.6 (0.7) Kit

LBA-22-1A ⅞ (22) Corrugated Coax 1 1.6 (0.7) Kit

LBA-22-2A ⅞ (22) Corrugated Coax 2 1.6 (0.7) Kit

LBA-22-3A ⅞ (22) Corrugated Coax 3 1.6 (0.7) Kit

LBA-22-4A ⅞ (22) Corrugated Coax 4 1.6 (0.7) Kit

LBA-33-1A 1¼ (33) Corrugated Coax 1 1.6 (0.7) Kit

LBA-42-1A 1⅝ (42) Corrugated Coax 1 1.6 (0.7) Kit

LBA-57-1A 2¼ (57) Corrugated Coax 1 1.6 (0.7) Kit

Product DescriptionThese innovative boot assembly kits feature a boot assembly and standard cushion insert in one convenient package. The unique boot assembly features a split, one-piece design that dramatically reduces installation time and difficulty. Boot assembly kits are designed to be fitted onto EP-series entry panels in wall/roof feed-thru applications.

Application• Entry solutions

Features/Benefits• One-piece design simplifies installation

Page 35: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-13

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Specifications

Sizein (mm)

A = 1.75 (44.5)B = 2.25 (57.2)C = 2.375 (60.3)D = 1.50 (38.1)

Mounts to Round adapters 1.5 to 4.5 inch (38.1 to 114.3 mm)

Material Stainless steel

Each Kit Includes • 10 stand-off adapters• One (1) installation instruction sheet

Not Included (Order Separately)

Round Adapter KitSnap-In Hanger Kit

Part Numbers and Physical Characteristics

Part NumberCompatible Round Adapter Size

in (mm) Unit of Measure

SA-SS200 1.5 to 3.5 (38.1 to 88.9) Kit

SA-SS300 2 to 4.5 (50.8 to 114.3) Kit

Rev 3/11 Ed 2.2

Product DescriptionThe Round Adapter Kit provides an easy method for supporting transmission lines to small diameter pipes or poles. The round adapter kit contains ten adjustable hose clamps.

Application• Coax hanger support

Round Adapter Kit

SpecificationsCompatible Pipe/Pole Diameterin (mm) Fits 1 (25.4) to 4 (101.6)

Material Stainless steel

Each Kit Includes • 10 adjustable hose clamps• One (1) installation instruction sheet

Not Included (Order Separately) Hanger KitsBrackets

Part Numbers and Physical Characteristics

Part NumberAdjustable Diameter

in (mm)Height

in (mm)Weightlbs (kg) Unit of Measure

RM-A100 1 to 2 (25.4 to 50.8) 0.5 (12.7) 0.8 (0.4) Kit

RM-A300 3 to 4 (76.2 to 101.6) 0.5 (12.7) 1.2 (0.5) Kit

Product DescriptionStand-Off Adapter Kits enable hangers to be mounted to 1.5 inch (31.8 mm) or larger round adapters. The stand-off adapter is available in stainless steel to provide excellent corrosion resistance and ensure long term integrity in extreme weather applications.

Application• Coax hanger support

Stand-Off Adapter Kit

A

B C

D¾ in (19.1 mm)

hole for snap-in hanger

⅛ x ¾ in (3.2 x 19.1 mm) mounting slot for a round

adapter or banding

Round Adapter(sold separately)

Snap-In Hanger(sold separately)

Page 36: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-14

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 8/11 Ed 2.3

Angle Adapter Kit

Product DescriptionThe Angle Adapter Kit allows the installer to easily secure hangers to solid angle members or in areas where mounting holes are not easily accessible. The stainless steel bolt locks the angle adapter to standard tower members or to mounting surfaces less than ⅞ inch (22.2 mm) thick. The toothed jaw effectively secures large volumes of coax in heavy wind and ice loading conditions.

Three (3), ⅜ inch (9.5 mm) tapped holes enable the angle adapter to accomodate hanger types which utilize ⅜ inch (9.5 mm) mounting hardware. Angle adpater kits include 10 angle adapters and 10 set bolts.

Application• Coax hanger support

Product DescriptionThe Three-Way Stand-Off Adapter Kit enables hangers to be mounted to round adapters. Each adapter accomodates up to three (3) snap-in hangers for supporting coaxial cable runs. The three-way stand-off adapter is available in stainless steel to provide excellent corrosion resistance and ensure long term integrity in extreme weather applications.

Application• Coax hanger support

SpecificationsCompatible Solid Angle Member Thickness in (mm) Fits up to ⅞ inch (22.2 mm)

Material Stainless steel

Each Kit Includes• 10 stainless steel angle adapters• 10 captive ⅜ inch (9.5 mm) set bolts• One (1) installation instruction sheet

Not Included (Order Separately) Hanger Kits

Part Numbers and Physical CharacteristicsPart Number Unit of Measure

AA-SL Kit

SpecificationsMounts to Round adapters

Material Stainless steel

Each Kit Includes • 10 three-way stand-off adapters• One (1) installation instruction sheet

Not Included (Order Separately)

Round Adapter KitSnap-In Hanger Kit

Part Numbers and Physical Characteristics

Part NumberOutside Length

in (mm)Outside Width

in (mm) Unit of Measure

L-SA-38 7.6 (19.3) 3.8 (98.0) Kit

Three-Way Stand-Off Adapter Kit

¾ in (19.1 mm) holes for snap-in hangers

⅛ x ¾ in (3.2 x 19.1 mm) mounting slots for a round

adapter or banding

Page 37: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-15

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/CommRev 10/10 Ed 2.2

Ground Buss Bar Kit

Product DescriptionThe Ground Buss Bar Kit provides a single, versatile solution to create a central ground point at your site. The ground buss bars are manufactured from ¼ inch (6.3 mm) thick solid, tinned copper and incorporate 26 pairs of 7⁄16 inch (11.1 mm) holes and 26 pairs of ¼ inch (6.4 mm) holes. By slotting one hole in each pair of 7⁄16 inch holes, the ground buss bar accommodates any lug hole spacing from ¾ inch (19.1 mm) to 1 inch (25.4 mm). Six (6) pairs of 7⁄16 inch holes are incorporated for lug connections to the ground system.

Application• Coax protection

Specifications

MaterialBuss bar: solid, tinned copperMounting hardware: stainless steelMounting brackets: glavanized steel

Each Kit Includes

• One (1) universal ground bar ¼ inch x 24 inch (6.4 mm x 0.6 m)

• One (1) mounting hardware set• One (1) mounting bracket set• One (1) installation instruction sheet

Part Numbers and Physical Characteristics

Part NumberThicknessin (mm)

Heightin (mm)

Widthin (mm)

Weightlbs (kg) Unit of Measure

GB0424TU 0.25 (6.3) 4 (102) 24 (610) 8 (3.6) Kit

Page 38: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-16

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 8/11 Ed 2.2

Weather Proofing Shell

Product DescriptionThe Weather Proofing Shell seals and protects connector joints from the environment. The shell also provides easy and fast installation of weather proofing on connector joints. The weather proofing shell is reusable.

Application• Coax/connector protection

SpecificationsMaterial Long glass PP and silicon rubber

Temperature Range °F (°C) -40 ~ +140 (-40 ~ +60)

Standards Compliance

UV ResistantUL and CLIP 68IEC60529ANSI C91191RoHS-compliant

Part Numbers and Physical CharacteristicsPart Number Connector Joint Compatibility Unit of Measure

WPSANT12D Antenna to ½ inch (12 mm) DIN Connector Each

WPS12158D ½ inch (12 mm) to 1⅝ inch (42 mm) DIN Connector Each

Page 39: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

C-17Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Product DescriptionThe Anti-Theft Hardware Kit is used to prevent removal of parts easily when bolted. The kit includes four (4) anti-theft bolts and a star head allen key.

Application• Coax protection

Anti-Theft hardware Kit

SpecificationsBolt Material Stainless steel

Each Kit Includes

• Four (4) anti-theft bolts measuring ¾ inch x 1 inch (19.1 mm x 25.4 mm)

• One (1) star head allen key• One (1) installation instruction sheet

Part Numbers and Physical CharacteristicsPart Number Unit of Measure

WATS-38 Kit

Page 40: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Page 41: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Technical Info

Table of ContentsMetric Measurement Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2Standard and Cut To Length Wood Reels For LHF, HFAC and HFSC Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3

Dimensional SpecificationsLHF-12D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4LHF-22D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5LHF-33D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6LHF-42D Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7HFAC-22D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8HFAC-42D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8HFSC-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9DIN Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-10N Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-11

Installation GuidesConnectors for LHF-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-12Connectors for LHF-22D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-14Connectors for LHF-33D and LHF-42D Cables. . . . . . . . . . . . . . . . . . . . . D-16Connectors for HFSC-12D Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-18

Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-20

Page 42: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-2 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Superior Essex uses the U.S. customary system of weights and measures as well as the metric equivalents. If you need help calculating these figures, please consult the conversion charts below.

Into MetricIf You Know Multiply By To Get

Length

milli-inch (mil) 25.40 microns (µm)

inches (in) 25.40 millimeters (mm)

inches (in) 2.54 centimeters (cm)

feet (ft) 30.48 centimeters (cm)

yards (yd) 0.91 meters (m)

miles (mi) 1.61 kilometers (km)

Area

sq. inches (in²) 6.45 sq. centimeters (cm²)

sq. feet (ft²) 0.09 sq. meters (m²)

sq. yards (yd²) 0.84 sq. meters (m²)

sq. miles (mi²) 2.59 sq. kilometers (km²)

acres 0.40 hectares (ha)

Mass (Weight)

ounces (oz) 28.35 grams (g)

pounds (lb) 0.45 kilograms (kg)

short tons 0.91 tons (t)

Temperature Fahrenheit (°F) Subtract 32, then multiply by 0.56 Celsius (°C)

Mass per Length

pounds per 1,000 feet (lbs/kft) 1.49 kilograms per

kilometers (kg/km)

Force

pounds force (lbf) 4.45 newtons (N)

foot–pounds (ft–lb) 1.36 newtons–meters (N–m)

pounds force per inches (lbf/in) 1.75 newtons per

centimeters (N/cm)

pounds per sq. inches (PSI) 6.89 kiloPascals (kPa)

Out of MetricIf You Know Multiply By To Get

Length

microns (µm) 0.04 milli-inch (mil)

millimeters (mm) 0.04 inches (in)

centimeters (cm) 0.39 inches (in)

meters (m) 3.28 feet (ft)

meters (m) 1.09 yards (yd)

kilometers (km) 3,280.84 feet (ft)

kilometers (km) 0.62 miles (mi)

Area

sq. centimeters (cm²) 0.16 sq. inches (in²)

sq. meters (m²) 1.20 sq. yards (yd²)

sq. kilometers (km²) 0.39 sq. miles (mi²)

hectares (ha) 2.47 acres

Weight

grams (g) 0.04 ounces (oz)

kilograms (kg) 2.20 pounds (lb)

tons (t) 1.10 short tons

Temperature Celsius (°C) Multiply by 1.80, then add 32 Fahrenheit (°F)

Weight per Unit Length

kilograms per kilometers (kg/km) 0.67 pounds per 1,000

feet (lbs/kft)

Force

newtons (N) 0.22 pounds force (lbf)

newtons–meters (N–m) 0.74 foot–pounds (ft–lb)

newtons per centimeters (N/cm) 0.57 pounds force per

inches (lbf/in)

kiloPascals (kPa) 0.15 pounds per sq. inches (PSI)

metric measurement Conversions

Page 43: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-3Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Standard Length Wood Reels

Part NumberCable Size

in (mm)Standard Length

ft (m)

Standard Reel Dimensions

Reel Weight lbs (kg)

Hole Size in (mm)

Flange in (mm)

Traverse in (mm)

LHF-12D ½ (12) 1,640 (500) 3.0 (75) 33 (850) 17 (430) 99 (45)

HFSC-12D ½ (12) 1,640 (500) 3.0 (75) 33 (850) 17 (430) 99 (45)

LHF-22D ⅞ (22) 1,640 (500) 4.3 (110) 47 (1,200) 26 (650) 352 (160)

LHF-22DU ⅞ (22) 1,640 (500) 4.3 (110) 47 (1,200) 26 (650) 352 (160)

LHF-22DWH ⅞ (22) 1,640 (500) 4.3 (110) 47 (1,200) 26 (650) 352 (160)

HFAC-22D ⅞ (22) 1,640 (500) 4.3 (110) 47 (1,200) 26 (650) 352 (160)

LHF-33D 1¼ (33) 1,640 (500) 4.3 (110) 69 (1,700) 30 (750) 551 (250)

LHF-42D 1⅝ (42) 1,640 (500) 4.3 (110) 83 (2,100) 40 (1,020) 1,069 (485)

LHF-42DU 1⅝ (42) 1,640 (500) 4.3 (110) 83 (2,100) 40 (1,020) 1,069 (485)

LHF-42DWH 1⅝ (42) 1,640 (500) 4.3 (110) 83 (2,100) 40 (1,020) 1,069 (485)

HFAC-42D 1⅝ (42) 1,640 (500) 4.3 (110) 83 (2,100) 40 (1,020) 1,069 (485)

Cut to Length Wood Reels

Part NumberCable Size

in (mm)Max. Cut Length

ft (m)

Standard Reel Dimensions

Reel Weight lbs (kg)

Hole Size in (mm)

Flange in (mm)

Traverse in (mm)

LHF-12D ½ (12) 400 (122) 3.1 (79) 36 (914) 26 (650) 94 (43)

HFSC-12D ½ (12) 400 (122) 3.1 (79) 36 (914) 26 (650) 94 (43)

LHF-22D ⅞ (22) 340 (104) 3.1 (79) 36 (914) 26 (650) 94 (43)

LHF-22DU ⅞ (22) 340 (104) 3.1 (79) 36 (914) 26 (650) 94 (43)

LHF-22DWH ⅞ (22) 340 (104) 3.1 (79) 36 (914) 26 (650) 94 (43)

HFAC-22D ⅞ (22) 340 (104) 3.1 (79) 36 (914) 26 (650) 94 (43)

LHF-33D 1¼ (33) 400 (122) 3.1 (79) 67 (1,702) 30 (762) 408 (185)

LHF-42D 1⅝ (42) 400 (122) 3.1 (79) 67 (1,702) 30 (762) 408 (185)

LHF-42DU 1⅝ (42) 400 (122) 3.1 (79) 67 (1,702) 30 (762) 408 (185)

LHF-42DWH 1⅝ (42) 400 (122) 3.1 (79) 67 (1,702) 30 (762) 408 (185)

HFAC-42D 1⅝ (42) 400 (122) 3.1 (79) 67 (1,702) 30 (762) 408 (185)Note: Reels meet the ISPN Publication No.15 Guidlines for regulating wood packaging material.

Flange x Traverse x Drum (F x T x D)

F = Flange DiameterT = Traverse (inside width between flanges)

D = Drum DiameterW = Overall Width (includes flanges)

Standard and Cut To Length Wood Reels For LHF, HFAC and HFSC Series

FD

T

FD

T

W

FD

T

FD

T

W

Page 44: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-4 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF-12d CableDimensional Specifications

Dimensional SpecificationsInner Conductor Diameter “a”in (mm) 0.196 ± 0.00078 (5.0 ± 0.02)

Dielectric Nominal Diameter “b”in (mm) 0.492 (12.5)

Outer Conductor Diameterin (mm)

Outside “c”: 0.559 ± 0.0039 (14.2 ± 0.1)Inside: 0.477 ± 0.0039 (12.14 ± 0.1)

Jacket Diameter “d”in (mm) 0.641 ± 0.0078 (16.3 ± 0.2)

a

b

c

d

Dielectric Highly Foamed Polyethylene

Inner ConductorCopper Clad Aluminum

Jacket Black Polyethylene

Outer ConductorAnnularly Corrugated Copper Tube

Corrugated Outer Conductor

Root Diameter:0.057 ± 0.0196 in(1.45 + 0.5 mm)

Pitch:0.190 ± 0.0039 in(4.85 ± 0.1 mm)

Nominal Thickness:0.0093 in (0.23 mm)

Depth:0.031 ± 0.0039 in(0.80 ± 0.10 mm)

Page 45: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-5Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF-22d CableDimensional Specifications

Dimensional SpecificationsInner Conductor Diameterin (mm)

Outside “a”: 0.370 ± 0.0039 (9.4 ± 0.1)Inside “a*”: 0.334 ± 0.0039 (8.5 ± 0.01)

Dielectric Nominal Diameter “b”in (mm) 0.925 (23.5)

Outer Conductor Diameterin (mm)

Outside “c”: 0.992 -0, + 0.0078 (25.2 -0, + 0.2)Inside: 0.862 -0, + 0.0078 (21.94 -0, + 0.2)

Jacket Diameter “d”in (mm) 1.110 ± 0.0118 (28.2 ± 0.3)

a

b

c

d

a*

Dielectric Highly Foamed Polyethylene

Inner ConductorCopper Tube

Jacket Black Polyethylene

Outer ConductorAnnularly Corrugated Copper Tube

Corrugated Outer Conductor

Root Diameter:0.079 ± 0.019 in(2.01 + 0.5 mm)

Pitch:0.271 ± 0.0039 in(6.90 ± 0.1 mm)

Nominal Thickness:0.0090 in (0.23 mm)

Depth:0.055 ± 0.0039 in

(1.40 ± 0.1 mm)

Page 46: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-6 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF-33d CableDimensional Specifications

Dimensional SpecificationsInner Conductor Diameterin (mm)

Outside “a”: 0.539 ± 0.0039 (13.7 ± 0.1)Inside “a*”: 0.50 ± 0.0039 (12.7 ± 0.06)

Dielectric Nominal Diameter “b”in (mm) 1.322 (33.6)

Outer Conductor Diameterin (mm)

Outside “c”: 1.433 ± 0.0078 (36.4 ± 0.2)Inside: 1.283 ± 0.0078 (32.6 ± 0.2)

Jacket Diameter “d”in (mm) 1.551 ± 0.011 (39.4 ± 0.3)

a

b

c

d

a*

Dielectric Highly Foamed Polyethylene

Inner ConductorCopper Tube

Jacket Black Polyethylene

Outer ConductorAnnularly Corrugated Copper Tube

Corrugated Outer Conductor

Root Diameter:0.090 ± 0.019 in(2.31 + 0.5 mm)

Pitch:0.334 ± 0.0039 in(8.5 ± 0.1 mm)

Nominal Thickness:0.011 in (0.30 mm)

Depth:0.062 ± 0.0098 in(1.60 ± 0.25 mm)

Page 47: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-7Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

LhF-42d CableDimensional Specifications

Dimensional SpecificationsInner Conductor Diameterin (mm)

Outside “a”: 0.700 ± 0.0078 (17.8 ± 0.2)Inside: 0.610 ± 0.0078 (15.5 ± 0.2)

Dielectric Nominal Diameter “b”in (mm) 1.712 (43.5)

Outer Conductor Diameterin (mm)

Outside “c”: 1.830 ± 0.0078 (46.5 ± 0.2)Inside: 1.625 ± 0.0078 (41.3 ± 0.2)

Jacket Diameter “d”in (mm) 1.968 ± 0.0118 (50.0 ± 0.3)

a

b

c

d

Dielectric Highly Foamed Polyethylene

Inner ConductorHelically Corrugated Copper Pipe

Jacket Black Polyethylene

Outer ConductorAnnularly Corrugated Copper Tube

Corrugated Outer ConductorRoot Diameter:0.1 ± 0.019 in(2.54 + 0.5 mm)

Pitch:0.397 ± 0.00393 in

(10.10 ± 0.1 mm)

Nominal Thickness:0.0118 in (0.3 mm)

Depth:0.090 ± 0.0039 in

(2.30 ± 0.1 mm)

Corrugated Inner Conductor

Pitch:0.318 ± 0.0039 in

(8.10 ± 0.1 mm)

Nominal Thickness:0.0098 in (0.25 mm)

Depth:0.035 ± 0.0078 in(0.90 ± 0.1 mm)

Page 48: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-8 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

hFAC-22d CableDimensional Specifications

a

b

c

d

Dielectric Closed Foam Polyethylene

Inner ConductorSmooth Copper Tube

Jacket Standard Black Polyethylene

Outer ConductorCorrugated AluminumTube

a

b

c

d

Dielectric Clsoed Foam Polyethylene

Inner ConductorCorrugated Copper Tube

Jacket Standard Black Polyethylene

Outer ConductorCorrugated Aluminum Tube

Dimensional SpecificationsInner Conductor Diameter "a"in (mm) ≤ 0.40 (10.16)

Dielectric Nominal Diameter “b”in (mm) ≤ 0.92 (23.50)

Outer Conductor Diameter "c"in (mm) ≤ 1.07 (27.18)

Jacket Diameter “d”in (mm) ≤ 1.16 (29.46)

Dimensional SpecificationsInner Conductor Diameter "a"in (mm) ≤ 0.71 (18.03)

Dielectric Nominal Diameter “b”in (mm) ≤ 1.71 (43.5)

Outer Conductor Diameter "c"in (mm) ≤ 1.87 (47.49)

Jacket Diameter “d”in (mm) ≤ 1.98 (50.29)

hFAC-42d CableDimensional Specifications

Page 49: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-9Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

hFSC-12d CableDimensional Specifications

Dimensional SpecificationsInner Conductor Diameter “a”in (mm) 0.141 ± 0.0007 (3.6 ± 0.02)

Dielectric Nominal Diameter “b”in (mm) 0.350 (8.9)

Outer Conductor Diameterin (mm)

Outside “c”: 0.480 ± 0.0039 (12.2 ± 0.1)Inside: 0.344 ± 0.00393 (8.74 ± 0.1)

Jacket Diameter “d”in (mm) 0.535 ± 0.0078 (13.6 ± 0.2)

Dielectric Highly Foamed Polyethylene

Inner ConductorCopper Clad Aluminum

a

b

c

d

Corrugated Outer Conductor

Root Diameter:1.040 -0.0078, ± 0.0157 in(1.02 -0.2, + 0.4 mm)

Pitch:0.125 ± 0.0039 in(3.20 ± 0.1 mm)

Nominal Thickness:0.0090 in (0.23 mm)

Depth:0.059 ± 0.0039 in

(1.50 ± 0.1 mm)

Jacket Black Polyethylene

Outer ConductorHelically Corrugated Copper Tube

Page 50: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-10 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

DIN for ½ inch (12 mm) DIN for ⅞ inch (22 mm)

2.65 in (67.4 mm)

0.86 in(21.8 mm)

SW 0.94 in (24.0 mm)

SW 0.75 in (19.0 mm)

FEM

ALE

2.62 in (66.5 mm)

1.39 in(35.2 mm)

FEM

ALE

SW 1.18 in (29.9 mm)

SW 1.18 in (29.9 mm)

2.57 in (65.4 mm)

0.86 in(21.8 mm)

SW 0.82 in (20.9 mm)

SW 0.75 in (19.0 mm)

MA

LE

2.81 in (71.5 mm)

1.39 in(35.2 mm)

SW 1.18 in (29.9 mm)

SW 1.18 in (29.9 mm)HEX 1.26 in (32.0 mm)

MA

LE

DIN for 1¼ inch (33 mm) DIN for 1⅝ inch (42 mm)

3.50 in (88.9 mm)

1.87 in(47.6 mm)

SW 1.75 in (44.5 mm)

FEM

ALE

SW 1.75 in (44.5 mm)

3.92 in (99.5 mm)

2.35 in(59.6 mm)

SW 2.24 in (56.9 mm)

FEM

ALE

SW 2.24 in (56.9 mm)

3.76 in (95.4 mm)

1.87 in(47.6 mm)

SW 1.75 in (44.5 mm)

MA

LE

SW 1.75 in (44.5 mm)

4.21 in (107.0 mm)

2.35 in(59.6 mm)

SW 2.24 in (56.9 mm)

MA

LE

SW 2.24 in (56.9 mm)

dIN ConnectorsDimensional Specifications

Page 51: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-11Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

N for ½ inch (12 mm) N for ⅞ inch (22 mm)

2.75 in (69.8 mm)

0.86 in(21.8 mm)

SW 0.82 in (20.9 mm)

SW 0.75 in (19.0 mm)

FEM

ALE

2.75 in (69.9 mm)

1.39 in(35.2 mm)

FEM

ALE

SW 1.18 in (29.9 mm)

SW 1.18 in (29.9 mm)

2.71 in (68.8 mm)

0.86 in(21.8 mm)

SW 0.82 in (20.9 mm)

SW 0.75 in (19.0 mm)

MA

LE

2.86 in (72.7 mm)

1.39 in(35.2 mm)M

ALE

SW 1.18 in (29.9 mm)

SW 1.18 in (29.9 mm)

N for 1¼ inch (33 mm) N for 1⅝ inch (42 mm)

3.76 in (95.5 mm)

1.87 in(47.6 mm)

SW 1.75 in (44.5 mm)

FEM

ALE

SW 1.75 in (44.5 mm)

4.13 in (105.0 mm)

2.35 in(59.6 mm)

SW 2.24 in (56.9 mm)

FEM

ALE

SW 2.24 in (56.9 mm)

3.86 in (98.0 mm)

1.87 in(47.6 mm)

SW 1.75 in (44.5 mm)

MA

LE

SW 1.75 in (44.5 mm)4.25 in (108.0 mm)

2.35 in(59.6 mm)

SW 2.24 in (56.9 mm)

MA

LE

SW 2.24 in (56.9 mm)

N ConnectorsDimensional Specifications

Page 52: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-12 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

9 mm

30 mm 50 mm

Connectors for LhF-12d CableInstallation Guide

CLh-12dm

CLh-12Nm

1

23

4

5

6 7

8

CLh-12NF

CLh-12dF

Connector Options• CLH-12DM• CLH-12NM• CLH-12NF• CLH-12DF

Required Tools• Cable Trimming Tool (CT-12D)• Cutting flier• Hacksaw• Flat file• Knife• Brush• Screw driver• Wrenches

A = Using Trimming Tool (CT-12D) B = Manual Trimming

1A Using the knife, remove the cable jacket leaving about 30 mm of the outer conductor exposed.

1B Using the knife, remove the cable jacket leaving about 50 mm of the outer conductor exposed.

2A Position the trimming tool (CT-12D) so that the fourth or fifth corrugation valley from the cable end fits into the corrugation guide.

2B Place the small O-ring in the second valley of the outer conductor from the edge of the jacket. Place a light film of grease around the surface of the O-ring.

3A Lightly press the blade into the cable and rotate the tool clockwise 10 to 20 times. You may hear a snapping sound indicating the outer conductor is fully cut.

3B Push the clamping nut onto the cable until it blocks against the jacket. Make sure that the slotted ferrule is seated within a valley of the corrugation.

4A Pull off the cut portion of the outer conductor and dielectric. Using the knife, trim away the jacket along the pre-scored mark.

4B Using the cutting flier, grip the outer conductor and tear it to obtain a flared contact surface all around the cable.

5A Using the cutting flier, cut the conductor, making a square flush cut to a 9 mm length.

5B Using the knife, cut the dielectric. Be careful not to score the inner conductor.

Page 53: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-13Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

TuRN

hOLd

Installing Connectors for LHF-12D Cable

A = Using Trimming Tool (CT-12D) B = Manual Trimming

6A Use the flat file to chamfer the inner conductor and clean it with the scouring pad.

6B Remove all the foam particles and adhesive from the inner conductor.

7A Place the small O-ring on the outer conductor in the second valley from the edge of the jacket. Place a light film of grease around the surface of the O-ring.

7B Use the flat file to chamfer the inner conductor and clean it with a scouring pad.

8A Push the clamping nut on the cable until it blocks against the jacket. Make sure the slotted ferrule is seated within a valley of the corrugation.

8B Run the tip of the screw driver around the outer conductor to separate the foam and to create an outer conductor flare.

9A Put the flare attachment of the tool (CT-12D) onto the cable and rotate the tool clockwise to prepare flared interface by flaring the end of the outer conductor. Remove all chips and clean the cable end.

9B Skip ahead to step 10.

10 Assemble the connector body onto the clamping nut.

11 Tighten the connection with wrenches to the torque value of 20 N·m maximum. Make sure that you hold clamping nut still and rotate only the outer body.

12 Installation is complete.

Note: These installation instructions have been written for qualified, experienced personnel. Please read them thoroughly before starting assembly work. Superior Essex disclaims any liability or responsibility for the result of improper or unsafe installation practices.

Page 54: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-14 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Connectors for LhF-22d CableInstallation Guide

38 mm60 mm

CLh-22dm

CLh-22Nm

1

23

4

5

6 78

CLh-22NF

CLh-22dF

Connector Options• CLH-22DM• CLH-22NM• CLH-22NF• CLH-22DF

Required Tools• Cable Trimming Tool (CT-22D)• Cutting flier• Hacksaw• Flat file• Knife• Brush• Screw driver• Wrenches

38 mm

A = Using Trimming Tool (CT-22D) B = Manual Trimming

1A Using the knife, remove the cable jacket leaving about 38 mm of the outer conductor exposed.

1B Using the knife, remove the cable jacket leaving about 60 mm of the outer conductor exposed.

2A Position the trimming tool (CT-22D) so that the fourth or fifth corrugation valley from the cable end fits into the corrugation guide.

2B Place the small O-ring in the second valley of the outer conductor from the edge of the jacket. Place a light film of grease around the surface of the O-ring.

3A Lightly press the blade into the cable and rotate the tool clockwise 10 to 20 times. You may hear a snapping sound indicating the outer conductor is fully cut.

3B Push the clamping nut onto the cable until it blocks against the jacket. Make sure that the slotted ferrule is seated within a valley of the corrugation.

4A Using the knife, trim away the jacket along the pre-scored mark.

4B Tightly grip the clamping nut and carefully cut off the cable with the hacksaw.

5A Inspect the cable trim to ensure that it is 38 mm.

5B After cutting, verify that the saw cut is flush with the end of the clamping nut. If the cable protrudes, file it with the clamping nut.

Page 55: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-15Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

hOLd

TuRN

Installing Connectors for LHF-22D Cable

A = Using Trimming Tool (CT-22D) B = Manual Trimming

6A Place the small O-ring on the outer conductor in the second valley from the edge of the jacket. Place a light film of grease around the surface of the O-ring.

6B Remove burrs from the inner contact with the knife.

7A Push the clamping nut onto the cable until it blocks against the jacket. Make sure the slotted ferrule is seated within a valley of the corrugation.

7B Run the tip of the screw driver around the outer conductor to separate the foam and to create an outer conductor flare.

8A Remove burrs from the inner contact with the knife.

8B Remove all the copper and foam particles with a brush.

9A Put the flare attachment of the tool (CT-22D) onto the cable and rotate the tool clockwise to prepare flared interface by flaring the end of the outer conductor. Remove all chips and clean the cable end with a brush.

9B Skip ahead to step 10.

10 Assemble the connector body onto the clamping nut.

11 Tighten the connection with wrenches to the torque value of 35 N·m maximum. Make sure that you hold clamping nut still and rotate only the outer body.

12 Installation is complete.

Note: These installation instructions have been written for qualified, experienced personnel. Please read them thoroughly before starting assembly work. Superior Essex disclaims any liability or responsibility for the result of improper or unsafe installation practices.

Page 56: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-16 Rev 9/10 Ed 2.1

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Connectors for LhF-33d and LhF-42d CablesInstallation Guide

Connector Options• CLH-33DM• CLH-33DF• CLH-42DF• CLH-42DM

Required Tools• Hacksaw• Flat file• Knife• Brush• Screw driver• Wrenches (57 mm)

CLh-33dm

CLh-42dF

1

2 3

4 5

6

CLh-33dF

CLh-42dm

38 mm

36.5 mm for CLh-33 47 mm for CLh-42

Manual Trimming Manual Trimming

1 Using the knife, trim away the jacket, removing it from the outer conductor.

5 Remove all the copper and foam particles with a brush.

2 Using the hacksaw, trim the cable leaving about 38 mm of the outer conductor exposed.

6 The flare diameter should be no more than 36.5 mm for CLH-33 or 47 mm for CLH-42.

3 Run the tip of the screw driver around the outer conductor to separate the foam and to create an outer conductor flare.

7 Place the small O-ring on the outer conductor in the first valley from the edge of the jacket. Place a light film of grease around the surface of the O-ring.

4 Remove burrs from the inner contact with the knife.

8 Push the clamping nut fully onto the cable unit until it blocks against the jacket. The outer conductor cutting line should also be aligned with the edge of the clamping nut.

Page 57: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-17Rev 9/10 Ed 2.1

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

hOLd

TuRN

Installing Connectors for LHF-33D and LHF-42D Cables

Manual Trimming

9 Assemble the connector body onto the clamping nut.

10 Tighten the connection with wrenches to the torque value of 50 N·m maximum for CLH-33 or 55 N·m maximum for CLH-42. Make sure that you hold the outer body still and rotate only the clamping nut.

12 Installation is complete.

Note: These installation instructions have been written for qualified, experienced personnel. Please read them thoroughly before starting assembly work. Superior Essex disclaims any liability or responsibility for the result of improper or unsafe installation practices.

Page 58: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-18

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm Rev 8/11 Ed 2.2

Connectors for hFSC-12d CableInstallation Guide

CLh-12dmS

CLh-12NmS

1

2

3

4

5

CLh-12NFS

CLh-12dFS

Connector Options• CLH-12DMS• CLH-12NMS• CLH-12NFS• CLH-12DFS

Installation Tools• Cable Trimming Tool (CT-12DS)

optional• Cutting pliers• Flat file• Knife• Wrenches:

• CHF 12NMS, CHF 12NFS 2 x 19 mm • CHF 12DMS, CHF 12DFS 2 x 21 mm • CHF 12DMS, Coupling Nut 32 mm

26 mm

10 mm16 mm

A = Using Trimming Tool (CT-12DS) B = Manual Trimming

1A Place the cable into the groove of the tool (CT-12DS).

1B Using the knife, remove the cable jacket leaving about 26 mm of the outer conductor exposed.

2A Lightly press the blade into the cable and rotate the tool clockwise 10 to 20 times. You may hear a snapping sound, indicating the outer conductor is fully cut.

2B Screw the threaded gasket close to the jacket. Make sure that the gasket threads are fully engaged. Apply supplied grease around the interface of the outer conductor and the gasket.

3A Remove the cut portion of the outer conductor and jacket by twisting off the cable end. Using the knife, trim away the jacket along the pre-scored mark..

3B Screw the threaded clamp onto the outer conductor until it blocks against the jacket.

4A Screw the threaded gasket close to the jacket. Make sure that the gasket threads are fully engaged. Apply supplied grease around the interface of the outer conductor and the gasket.

4B Using the cutting pliers, grip the outer conductor and tear it to obtain a flared contact surface all around the cable.

5A Screw the threaded clamp onto the outer conductor until it blocks against the jacket.

5B Skip ahead to step 7.

Page 59: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

d-19

TABL

E O

F CO

NTE

NTS

FEEd

ER C

ABL

ECO

NN

ECTO

RSA

CCES

SORI

ESTE

ChN

ICA

L IN

FOPA

RT N

um

BER

INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

7 Ensure that the outer condcutor is flared completely around the circumference of the threaded clamp.

8 Using the knife, cut the dielectric and completely scrape away the foam and adhesive particles from the inner conductor. Be careful not to score the inner conductor.

9 Using the cutting pliers, cut the inner conductor to a 8 mm length.

10 Use the flat file to chamfer the inner conductor and then clean it with a scouring pad.

11 Assemble the connector body onto the clamping nut.

12 Tighten the connection with wrenches to the torque value of 15 ft-lb (20 N·m) maximum. Make sure that you hold the clamping nut still and rotate only the outer body.

13 Installation is complete.

Note: These installation instructions have been written for qualified, experienced personnel. Please read them thoroughly before starting assembly work. Superior Essex disclaims any liability or responsibility for the result of improper or unsafe installation practices.

Rev 8/11 Ed 2.2

Installing Connectors for HFSC-12D Cable

A = Using Trimming Tool (CT-12DS)

6A Using the cutting pliers, grip the outer conductor and tear it to obtain a flared contact surface all around the cable.

hOLd

TuRN

TuRN

8 mm

Page 60: QUICK LINKS - Accu-Tech · 2017-10-09 · Cable, Connectors, Jumpers and Accessories Surge Arrestors Universal Weatherproofing Kit Coaxial Cables Hangers Lace-Up Hoisting Grip Grounding

TABLE O

F CON

TENTS

FEEdER CA

BLECO

NN

ECTORS

ACCESSO

RIESTECh

NICA

L INFO

PART N

um

BER INd

Ex

Toll Free 800.551.8948 | Fax 770.657.6807 | SuperiorEssex.com/Comm

Part Number Index

AA-SL C-14AGDMDF02 C-10AG-NFNF C-10ATDMDF700 C-9AT-DMDF-W C-9ATNMNF700 C-9AT-NMNF-W C-9CHFA-22DF B-4CHFA-22DM B-4CHFA-42DF B-4CHFA-42DM B-4CHFS-12DFR B-5CHFS-12DF B-5CHFS-12DMR B-5CHFS-12DM B-5CHFS-12NFR B-7CHFS-12NF B-7CHFS-12NMR B-7CHFS-12NM B-7CLH-12DFR B-3CLH-12DF B-3CLH-12DMR B-3CLH-12DM B-3CLH-12NFR B-6CLH-12NF B-6CLH-12NMR B-6CLH-12NM B-6CLH-22DF B-3CLH-22DM B-3CLH-22NF B-6CLH-22NM B-6CLH-33DF B-3CLH-33DM B-3CLH-33NF B-6CLH-33NM B-6CLH-42DF B-3CLH-42DM B-3CLH-42NF B-6CLH-42NM B-6GB0424TU C-15HFAC-22D A-5HFAC-42D A-5HFSC-12D A-6J12-1DMDM C-2J12-1NMNM C-2J12-2DMDM C-2J12-2NMNM C-2J12-3DMDM C-2J12-3NMNMR C-2J12-3NMNM C-2J12-4DMDM C-2J12-4NMNM C-2J12-5DMDF C-2J12-5DMDM C-2J12-5NMNM C-2J12-6NMNMR C-2LBA-12-1A C-12LBA-12-2A C-12LBA-12-3A C-12LBA-12-4A C-12LBA-12-5A C-12LBA-22-1A C-12LBA-22-2A C-12LBA-22-3A C-12LBA-22-4A C-12LBA-33-1A C-12LBA-42-1A C-12LBA-57-1A C-12LBHS12NH C-8

LBHS22NH C-8LBHS33NH C-8LBHS42NH C-8L-CT-12D C-11L-CT-22D C-11L-FT-42D* C-11L-GK-C12 C-5L-GK-C22 C-5L-GK-C33 C-5L-GK-C42 C-5LHF-12D A-2LHF-22DU A-3LHF-22DWH A-4LHF-22D A-2LHF-33D A-2LHF-42DU A-3LHF-42DWH A-4LHF-42D A-2L-HG-12L C-4L-HG-12 C-4L-HG-22L C-4L-HG-22 C-4L-HG-33L C-4L-HG-33 C-4L-HG-42L C-4L-HG-42 C-4L-SA-38 C-14L-SH-S12 C-7L-SH-S22 C-7L-SH-S33 C-7L-SH-S42 C-7L-SH-U12 C-6L-SH-U22 C-6L-SH-U33 C-6L-SH-U42 C-6L-WK-U C-3RM-A100 C-13RM-A300 C-13SA-SS200 C-13SA-SS300 C-13SSHAK3812* C-7WATS-38 C-17WPS12158D C-16WPSANT12D C-16

Part Number Page Part Number Page Part Number Page Part Number Page Part Number Page Part Number Page