quick setup guide - briggs &...

2
Not for Reproduction Move Generator to Safe Operating Location 1. Move generator outside to a flat, level surface, in an area that will not accumulate deadly exhaust gas. Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in minutes. You CANNOT smell it, see it, or taste it. Operate ONLY outside far away from windows, doors and vents. Install carbon monoxide alarms. DO NOT run this product inside homes or garages, even if using fans or opening doors and windows. Direct exhaust AWAY from windows, doors, and vents. 5 2. To reduce the risk of exhaust heat or exhaust gases igniting nearby combustible material, keep at least 5 ft. (1.5 m) clearance on all sides of generator, including overhead. Start Generator 1. Make sure unit is on a level surface. Disconnect all electrical loads from the generator. 2. Turn the fuel valve (E) to ON (I) position. 6 3. Move choke lever (F) to CHOKE ( ) position. 7 4. Push engine switch (G) to ON (I) position. 8 5. Pull starter rope handle (H) slowly until resistance is felt. Then pull cord rapidly to overcome compression, prevent kickback, and start engine. 9 6. Slowly move choke lever (F) to RUN ( ) position as engine warms. 7 7. If engine does not start, refer to operator’s manual for detailed starting instructions. Plug in Items to be Powered 1. Let engine stabilize and warm up for a few minutes after starting. NOTICE DO NOT connect 240 Volt loads to the 120 Volt GFCI duplex receptacles. NOTICE DO NOT connect 3-phase loads to the generator. NOTICE DO NOT connect 50 Hz loads to the generator. NOTICE DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator, in Operator’s Manual. 2. Ensure the circuit breaker (K) on the control panel is in the ON (I) position. 10 3. The 120 Volt AC, 20A duplex GFCI receptacles (J) are provided with “push to reset” circuit breakers (M) to protect the generator against electrical overload. 10 4. The 120/240 Volt (L) AC, 30A locking receptacle is provided with a 2 pole rocker switch circuit breaker (K) to protect the generator against electrical overload. 10 NOTICE Before using the GFCI receptacle, ALWAYS push the test and reset buttons to insure it works. 5. Connect electrical loads in OFF position, then turn ON for operation. NOTICE When plugging into the 120 Volt (J) GFCI receptacles, plug items to be powered in sequence as shown. 10 6. Plug in and turn on the desired 120 Volt (J) and/or 240 Volt (L) AC, single phase, 60 Hz electrical loads. 10 Shut Down Generator 1. Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. 3. Push engine switch (G) to OFF (0) position. 8 4. Move fuel valve (E) to OFF (0) position. 6 5. To prepare for storage, refer to Operator’s Manual. Unpack Generator 1. Set the carton on a rigid, flat surface. 2. Remove everything from carton except generator. 3. Open carton completely by cutting each corner from top to bottom. 4. Ensure you have all included items prior to assembly. If items are damaged or missing, call 1-800-743-4115. 5. Leave generator on carton to install wheel kit. Add Engine Oil and Fuel NOTICE Be sure you have attached wheels and support leg prior to this step. NOTICE You MUST properly fill engine with oil before attempting to start generator. NOTICE DO NOT use unapproved fuel such as E15 and E85. DO NOT mix oil in fuel or modify engine to run on alternate fuels. 1. Move generator outdoors to a flat, level surface. 2. Clean area around oil fill and remove yellow oil fill cap/dipstick ( ). 3. Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening to the Full mark (A) on dipstick. 4. Replace oil fill cap and fully tighten. 5. Clean area around fuel cap ( ), remove cap. 3 6. Slowly add unleaded gasoline (B) to fuel tank (C). Be careful not to fill above the baffle (D). This allows adequate space for fuel expansion as shown. 4 7. Replace fuel cap, and let any spilled fuel evaporate before starting engine. Items Included: (Not Shown) Operator’s Manual Wheel kit with instruction sheet Bottle of engine oil Items Needed: (Not Included) Carbon monoxide (CO) alarm(s) Utility knife 12 mm and 16 mm wrenches Unleaded fuel (minimum 87 octane) © 2015 Briggs & Stratton Power Products Group, LLC. All rights reserved. Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation. This generator is certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard PGMA G200 (Standard for Testing and Validating Performance of Portable Generators). Quick Setup Guide Portable Generator WARNING Failure to read and follow the operator’s manual and all operating instructions could result in death or serious injury. WARNING Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in minutes. You CANNOT smell it, see it, or taste it. Operate ONLY outside far away from windows, doors and vents. Install carbon monoxide alarms. DO NOT run this product inside homes or garages, even if using fans or opening doors and windows. Direct exhaust AWAY from windows, doors, and vents. WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury. DO NOT operate under wet conditions. WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury. Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. Let spilled fuel evaporate before starting engine. Always allow space for fuel expansion. WARNING Hot exhaust and reflective exhaust gases could cause fires resulting in death or serious injury. Keep at least 5 ft. (1.5 m) clearance from any combustibles or structures, including overhead. 80013245, Rev - 4 FUEL TANK B D C WARNING Damaged or overloaded electrical cords could overheat, arc, and burn resulting in death or serious injury. ONLY use cords rated for your loads. Follow all safeties on electrical cords. Inspect cord sets before each use. 3 5 Install carbon monoxide alarms inside your home. Without working carbon monoxide alarms, you will not realize you are getting sick and dying from carbon monoxide. CARBON MONOXIDE ALARM(S) USE OUTDOORS - AVOID CARBON MONOXIDE POISONING point away from home MUFFLER A 2 1 2 2 1 1 6 E 7 F 9 H Have Questions? Do not return to store. We can help. Call Customer Service Toll-Free 1-800-743-4115 or visit our website: www.powerboss-equipment.com 8 G 3 L J K 1 4 2 10 J M

Upload: others

Post on 04-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quick Setup Guide - Briggs & Strattonbsintek.basco.com/BriggsDocumentDisplay/ngjpyGT7p-ZVj5K1w.pdf · d'un circuit de commutateur à bascule disjoncteur bipolaire (K) afin de protéger

Not for

Reprod

uctio

n

Move Generator to Safe Operating Location1. Move generator outside to a flat, level surface, in an area

that will not accumulate deadly exhaust gas. Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in minutes. You CANNOT smell it, see it, or taste it. Operate ONLY outside far away from windows, doors and vents. Install carbon monoxide alarms. DO NOT run this product inside homes or garages, even if using fans or opening doors and windows. Direct exhaust AWAY from windows, doors, and vents. 5

2. To reduce the risk of exhaust heat or exhaust gases igniting nearby combustible material, keep at least 5 ft. (1.5 m) clearance on all sides of generator, including overhead.

Start Generator1. Make sure unit is on a level surface. Disconnect all electrical

loads from the generator. 2. Turn the fuel valve (E) to ON (I) position. 6

3. Move choke lever (F) to CHOKE ( ) position. 7

4. Push engine switch (G) to ON (I) position. 8

5. Pull starter rope handle (H) slowly until resistance is felt. Then pull cord rapidly to overcome compression, prevent kickback, and start engine. 9

6. Slowly move choke lever (F) to RUN ( ) position as engine warms. 7

7. If engine does not start, refer to operator’s manual for detailed starting instructions.

Plug in Items to be Powered1. Let engine stabilize and warm up for a few minutes after

starting.

NOTICE DO NOT connect 240 Volt loads to the 120 Volt GFCI duplex receptacles.NOTICE DO NOT connect 3-phase loads to the generator.NOTICE DO NOT connect 50 Hz loads to the generator.NOTICE DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator, in Operator’s Manual.2. Ensure the circuit breaker (K) on the control panel is in the

ON (I) position. 10

3. The 120 Volt AC, 20A duplex GFCI receptacles (J) are provided with “push to reset” circuit breakers (M) to protect the generator against electrical overload. 10

4. The 120/240 Volt (L) AC, 30A locking receptacle is provided with a 2 pole rocker switch circuit breaker (K) to protect the generator against electrical overload. 10

NOTICE Before using the GFCI receptacle, ALWAYS push the test and reset buttons to insure it works.5. Connect electrical loads in OFF position, then turn ON for

operation.NOTICE When plugging into the 120 Volt (J) GFCI receptacles, plug items to be powered in sequence as shown. 10 6. Plug in and turn on the desired 120 Volt (J) and/or 240 Volt (L)

AC, single phase, 60 Hz electrical loads. 10

Shut Down Generator1. Turn OFF and unplug all electrical loads from generator

panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON.

2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.

3. Push engine switch (G) to OFF (0) position. 8 4. Move fuel valve (E) to OFF (0) position. 6

5. To prepare for storage, refer to Operator’s Manual.

Unpack Generator1. Set the carton on a rigid, flat surface.2. Remove everything from carton except generator.3. Open carton completely by cutting each corner from top to

bottom. 4. Ensure you have all included items prior to assembly.

If items are damaged or missing, call 1-800-743-4115. 5. Leave generator on carton to install wheel kit.

Add Engine Oil and FuelNOTICE Be sure you have attached wheels and support leg prior to this step.NOTICE You MUST properly fill engine with oil before attempting to start generator.NOTICE DO NOT use unapproved fuel such as E15 and E85. DO NOT mix oil in fuel or modify engine to run on alternate fuels.1. Move generator outdoors to a flat, level surface. 2. Clean area around oil fill and remove yellow oil fill

cap/dipstick ( ). 3. Using oil funnel (optional), slowly pour contents of provided oil

bottle into oil fill opening to the Full mark (A) on dipstick.4. Replace oil fill cap and fully tighten.5. Clean area around fuel cap ( ), remove cap. 3

6. Slowly add unleaded gasoline (B) to fuel tank (C). Be careful not to fill above the baffle (D). This allows adequate space for fuel expansion as shown. 4

7. Replace fuel cap, and let any spilled fuel evaporate before starting engine.

Items Included: (Not Shown)• Operator’s Manual • Wheel kit with instruction sheet • Bottle of engine oil

Items Needed: (Not Included)

• Carbon monoxide (CO) alarm(s) • Utility knife • 12 mm and 16 mm wrenches • Unleaded fuel (minimum 87 octane)

© 2015 Briggs & Stratton Power Products Group, LLC. All rights reserved.Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation.This generator is certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard PGMA G200 (Standard for Testing and Validating Performance of Portable Generators).

Quick Setup GuidePortable Generator

WARNING Failure to read and follow the operator’s manual and all operating instructions could result in death or serious injury.

WARNING Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in minutes. You CANNOT smell it, see it, or taste it. Operate ONLY outside far

away from windows, doors and vents. Install carbon monoxide alarms. DO NOT run this product inside homes or garages, even if using fans or opening doors and windows. Direct exhaust AWAY from windows, doors, and vents.

WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury. DO NOT operate under wet conditions.

WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury. Turn generator

engine OFF and let it cool at least 2 minutes before removing fuel cap. Let spilled fuel evaporate before starting engine. Always allow space for fuel expansion.

WARNING Hot exhaust and reflective exhaust gases could cause fires resulting in death or serious injury. Keep at least 5 ft. (1.5 m) clearance from any combustibles or

structures, including overhead.

80013245, Rev -

4

FUEL

TANK

B

DC

WARNING Damaged or overloaded electrical cords could overheat, arc, and burn resulting in death or serious injury. ONLY use cords rated for your loads. Follow all safeties on electrical cords. Inspect cord sets before each use.

3

5

Install carbon monoxide alarms inside your home. Without working carbon monoxide alarms, you will not realize you are getting sick and dying from carbon monoxide.

CARBON MONOXIDE ALARM(S)

USE OUTDOORS - AVOID CARBON MONOXIDE POISONING

point awayfrom home

MUFFLER

A

2

1

2

21

1

6

E

7

F

9

H

Have Questions?Do not return to store. We can help.Call Customer Service Toll-Free 1-800-743-4115or visit our website: www.powerboss-equipment.com

8

G

3

LJK

1

4

2

10

J M

Page 2: Quick Setup Guide - Briggs & Strattonbsintek.basco.com/BriggsDocumentDisplay/ngjpyGT7p-ZVj5K1w.pdf · d'un circuit de commutateur à bascule disjoncteur bipolaire (K) afin de protéger

Not for

Reprod

uctio

n

Déplacement de la génératrice vers un emplacement sécuritaire1. Déplacez la génératrice à l'extérieur, vers une surface

plane, dans un endroit où les gaz d'échappement mortels ne s'accumuleront pas. Les gaz d'échappement contiennent du monoxyde de carbone, un gaz toxique pouvant provoquer la mort en quelques minutes. Il s'agit d'un gaz que vous NE pouvez NI voir, NI sentir, NI goûter. Utilisez SEULEMENT à l'extérieur, loin des fenêtres, des portes et des évents. Installez des avertisseurs de monoxyde de carbone. NE FAITES PAS fonctionner ce produit à l'intérieur des maisons ou des garages, même en utilisant des ventilateurs ou en ouvrant portes et fenêtres. Dirigez la sortie d'échappement loin des fenêtres, portes et évents. 5

2. Laissez un dégagement d’au moins 1,5 m (5 pi.) tout autour de la génératrice, y compris au-dessus, afin de réduire le risque que la chaleur et des gaz d’échappement enflamment les matériaux combustibles proches.

Démarrez la génératrice1. Assurez-vous que l’unité se trouve sur une surface de niveau.

Débranchez toutes les charges électriques de la génératrice. 2. Tournez la vanne d'essence (E) vers la position ON (I). 6

3. Déplacez le levier d’étrangleur (F) vers la position CHOKE ( ). 7

4. Poussez l'interrupteur du moteur (G) en position ON (I). 8

5. Tirez lentement sur la corde (H) de lancement jusqu’à ce que vous sentiez une résistance. Tirez alors rapidement sur le câble pour dépasser la résistance de la compression, empêcher les effets de recul et démarrer le moteur. 9

6. Déplacez lentement le levier d’étrangleur (F) vers la position RUN ( ) pendant le réchauffement du moteur. 7

7. Si le moteur ne démarre pas, reportez-vous au manuel d'utilisation pour des instructions détaillées.

Branchement des unités à alimenter1. Laissez le moteur se réchauffer et se stabiliser durant

quelques minutes à la suite du démarrage.

AVIS NE connectez PAS de charges en 240 Volts aux prises doubles en 120 Volts.AVIS NE connectez PAS de charges triphasées à la génératrice.AVIS NE connectez PAS de charges en 50 Hz à la génératrice.AVIS NE SURCHARGEZ PAS LA GÉNÉRATRICE. Consultez la rubrique Ne surchargez pas votre génératrice dans le Manuel d'utilisation.2. Assurez-vous que les disjoncteurs (K) sur le panneau de

commande soient sur la position ON (I). 10

3. Des prises en 120 Volts C.A, 20 Ampères (J) sont munies d’un disjoncteur de type “pousser pour réarmer” (M) afin de protéger la génératrice contre les surtensions. 10

4. La prise à verrouillage 120/240 Volts (L) C.A. 30A est munie d'un circuit de commutateur à bascule disjoncteur bipolaire (K) afin de protéger la génératrice contre les surcharges électriques. 10

AVIS Avant d’utiliser la prise CFCI, appuyez toujours sur le bouton d’essai pour s’assurer qu’il fonctionne.5. Connectez les charges électriques lorsqu'elles sont en

position OFF, puis placez-les en position ON pour utilisation.AVIS lors du branchement dans les prises GFCI en 120 Volts (J), branchez les unités à alimenter dans l'ordre indiqué. 10 6. Raccordez et tournez vers la position désirée pour les

appareils électriques fonctionnant en 120 V (J) et ou 240 V (L) C.A., monophasés 60 Hz. 10

Arrêt de la génératrice1. Éteignez tous les appareils électriques et débranchez-les des

prises du panneau de la génératrice. Ne démarrez ni n’arrêtez JAMAIS le moteur lorsque des appareils électriques y sont branchés et en fonctionnement.

2. Laissez le moteur fonctionner sans charge durant plusieurs minutes afin de permettre à la température interne du moteur et de la génératrice de se stabiliser.

3. Poussez l'interrupteur du moteur (G) en position OFF (0). 8 4. Tournez la vanne de carburant (E) vers la position OFF (0). 6

5. Reportez-vous au Manuel d’utilisation au sujet de la préparation pour l’entreposage.

Déballage de la génératrice1. Placez la boîte sur une surface plane rigide.2. Enlevez tous les composants de la boîte d’expédition à

l’exception de la génératrice.3. Ouvrez complètement la boîte en coupant chaque coin de

haut en bas. 4. Assurez-vous d'avoir tous les articles inclus avant de

commencer l'assemblage. Si des articles sont manquants ou endommagés, appelez le 1-800-743-4115.

5. Laissez la génératrice sur la boîte d’expédition afin d’installer les roues.

Ajoutez de l'huile moteur et du carburantAVIS Veillez à immobiliser les roues et le pied-support avant cette étape.AVIS Vous DEVEZ remplir adéquatement le moteur avec de l’huile, avant d’essayer de faire démarrer la génératrice.AVIS N'utilisez PAS d'essence non approuvée telle que les types E15 et E85. NE MÉLANGEZ PAS l'huile avec l'essence et ne modifiez pas le moteur afin qu'il fonctionne avec d'autres types de carburant.1. Déplacez la génératrice à l’extérieur vers une surface plane. 2. Nettoyez la surface autour de l’orifice de remplissage d’huile

et enlevez le bouchon jaune de remplissage d’huile avec la jauge d’huile ( ). 1

3. À l’aide d’un entonnoir pour huile (optionnel), versez lentement le contenu des deux bouteilles d’huile fournies dans l’orifice de remplissage jusqu’au repère maximum FULL (A) sur la jauge d’huile. 2

4. Replacez le bouchon de remplissage d'huile et serrez-le solidement. 1 2

5. Nettoyez la surface autour du bouchon du réservoir d'essence ( ), enlevez le bouchon. 3

6. Ajoutez lentement de l’essence sans plomb (B) dans le réservoir d’essence (C). Faites attention de ne pas dépasser la chicane (D) en remplissant. Cela laisse un espace adéquat pour l'expansion de l'essence, tel que montré. 4

7. Remettez le bouchon à essence et laissez l’essence déversée s’évaporer avant de démarrer le moteur.

Articles fournis: (Non représentés)• Manuel d'utilisation • Kit de roue avec instructions • Bidon d'huile moteur

Articles nécessaires: (Non inclus)

• Avertisseur(s) de monoxyde de carbone • Couteau multiusages • clés de 12 mm et 16 mm • Carburant sans plomb (indice minimum d'octane de 87)

© 2015 Briggs & Stratton Power Products Group, LLC. Tous droits réservés.Nous nous sommes efforcés de fournir dans ce document des informations exactes et à jour. Toutefois, nous nous réservons le droit de modifier ou même d'améliorer le produit et ce document à tout moment sans préavis ou obligation de notre part.Cette génératrice est certifiée conforme à la norme CSA (Canadian Standards Association) No C22.2 100-04 (moteurs et génératrices) et classée en conformité avec la norme PGMA (Association des fabricants de génératrices mobiles) No G200 (norme pour tester et valider la performance des génératrices mobiles).

4

FUEL

TANK

B

DC

3

A

2

1

6

E

7

F

9

H

8

G

3

LJK

1

4

2

10

J M

AVERTISSEMENT L'omission de lire et de se conformer au manuel de l'utilisateur et à toutes les directives d'utilisation avant d'utiliser le produit peut entraîner la mort ou des blessures graves.

AVERTISSEMENT Les gaz d'échappement contiennent du monoxyde de carbone, un gaz toxique pouvant provoquer la mort en quelques minutes. Il s'agit d'un

gaz que vous NE pouvez NI voir, NI sentir, NI goûter. Utilisez SEULEMENT à l'extérieur, loin des fenêtres, des portes et des évents. Installez des avertisseurs de monoxyde de carbone. NE FAITES PAS FONCTIONNER ce produit à l'intérieur des habitations ou des garages, même en utilisant des ventilateurs ou en ouvrant portes et fenêtres. ÉLOIGNEZ la sortie d'échappement des fenêtres, portes et évents.

AVERTISSEMENT La tension électrique de la génératrice peut causer un choc électrique et des brûlures pouvant entraîner la mort ou des blessures graves. NE faites PAS fonctionner dans un milieu détrempé.

AVERTISSEMENT Le carburant et ses vapeurs sont extrêmement inflammables et explosifs et pourraient causer des brûlures , un incendie ou une explosion

susceptibles d'entraîner des blessures graves, voire la mort. Éteignez la génératrice et laissez-la refroidir pendant au moins 2 minutes avant de retirer le bouchon à essence. Laissez le carburant déversé s'évaporer avant de démarrer le moteur. Laissez toujours suffisamment d'espace pour l'expansion du carburant.

AVERTISSEMENT Les gaz d'échappement et d'échappement réfléchi chauds peuvent causer un incendie et entraîner la mort et des blessures graves. Laissez un dégagement d'au moins

1,5 m (5 pi.) autour de tous matériaux combustibles et structures, y compris au-dessus. 5

ALARME(S) DE MONOXYDE DE CARBONE

UTILISEZ À L'EXTÉRIEUR – ÉVITEZ L'EMPOISONNEMENT AU MONOXYDE DE CARBONE

ne pas pointer vers la résidence

SILENCIEUXInstallez les alarmes de monoxyde de carbone à l'intérieur de votre demeure. Sans alarmes de monoxyde de carbone en état de marche, vous pourriez ne pas réaliser que vous devenez malade et en voie de mourir du monoxyde de carbone.

AVERTISSEMENT Les cordons électriques endommagés ou surchargés peuvent surchauffer, créer un arc électricque, et brûler, entraînant la mort ou des blessures graves. N'utilisez que des cordons ayant

des valeurs nominales appropriées à vos charges. Veuillez suivre toutes les consignes de sécurité relatives aux cordons électriques. Inspectez l’ensemble de cordons d’alimentation avant chaque utilisation.

Guide d'installation rapideGénératrice mobile

Vous avez des questions ?Ne retournez pas au magasin Nous pouvons vous aider.Appelez le service à la clientèle au numéro sans frais 1-800-743-4115ou visitez notre site Web à l'adresse www.powerboss-equipment.com