Quick Start Manual
www.waiglobal.com
WAI1000 Tester Quick Start Manual
WAI1000 Tester Quick Start Manual
Please read this manual before first using your WAI1000 Tester and familiarize yourself withit’s functions to ensure safe operation of the unit.
DisclaimerAll information, illustrations, and specifications contained in this technical instruction manualare based on the latest information available at the time of publication. WAI Global reserve theright to make changes at any time without obligation to notify any person or organization ofsuch revisions or changes.
CopyrightNo part of this manual may be reproduced, stored in a retrieval system or transmitted, in anyform or by any means, electronic, mechanical, photocopying, recording, or otherwise withoutthe prior written permission of WAI Global.
Controls
1- LCD Display2- Control Knob used to operate device options3- B+ terminal, power supply (use only 12V input)4- B- terminal, power supply5- COM terminal - control line for ECU protocols6- DFM monitor positive field order7- DFM monitor negative field order
Turn knob clockwise or counter clockwise toswitch between options (1&2).Confirm your selection by pushing the knob (3).
WAI1000 Tester Quick Start Manual EN
Common applications:
Connecting WAI1000 with Alternator
Protocol options screen
Protocol
SIG
RVLCOM
Ver 1.01 Rev 2.00
After powering the WAI1000 you will see the following options to choose from:
Protocols
COM (LIN and BSS / BSD)CRLOPDL-RVCSIGDFM
l
l
l
l
l
l
l
COM - BMW, Mercedes-Benz, VW GroupC - Honda, Hyundai, MitsubishiRLO - Toyota, LexusPD - MazdaL-RVC - Chevrolet, Opel, GMSIG - Ford, Volvo, MazdaDFM - Various
Steps:
1- Connect red clamp (3) to b+ terminal of alternator or to the + terminal of battery2- Connect black clamp (4) to ground (alternator housing) or minus terminal of battery3- Connect green wire (5) to the com/lin/bss/sig/rc/rlo/c/d terminal*4- Connect blue wire to the dfm+(6) or dfm-(7) / fr (6,7)*Note - green wire is always used to control alternator
After connecting the WAI1000 to a power source it will bring up the protocol menu.Please select the proper protocol with the control knob and submit your option by pressing it.
WAI1000 Tester Quick Start Manual
COM (LIN and BSS / BSD) TerminalDigital regulators are automatically detected by the WAI1000.
Sample plugs:
COM DFM LINCOM COM/BSS2COM BSSLIN BSDCOM COM/LIN2C
2 1
Main screen LIN
Testing
Main screen BSS / BSD
LIN 1.3BOSCHClass 03TME
12.6 Vread
Vset
DFM%
12.6BSSID 05M E
12.6 Vread
Vset
DFM%
12.6
1- Lin protocol version2- Vendor3- Class of regulator4- Errors (T=Temperature, M=Mechanical, E=Electrical)5- Read Voltage value6- Setting of regulator Voltage7- DFM
1- Protocol2- Regulator ID3- Errors (T=Temperature, M=Mechanical, E=Electrical)4- Read Voltage value5- Setting of regulator Voltage6- DFM
l
l
l
l
l
l
Speed up the alternator to about 1000 RPMWait for the WAI1000 to connect to the regulatorWhen information about the regulator shows up you can controlthe Voltage by rotating the control knobWhen changing the Vset value Vread should decrease orincrease accordinglyIf the regulator supports DFM while Vset changes the valueshould also changePressing the control knob makes the WAI1000 go back to theprotocol selection screen
WAI1000 Tester Quick Start Manual EN
1- Terminal2- Read Voltage value3- Setting of regulator Voltage4- DFM
C TerminalSample plugs:
Testing H/L setpoint and PWM type C terminal regulators
Main screen C
l
l
l
l
H/L setpoint type: Dial knob clockwise for the High (H) set pointuntil Vset = 15.8V. The Vread value will equal the upper set pointof the regulator (it will not match Vset). Dial the knob counterclockwise for the Low (L) set point until the Vset = 11.4V. TheVread value will equal the lower set point of the regulator (it willnot match Vset). Note: Dial settings between the High (H) andLow (L) will not be accurate.PWM type: Dial knob clockwise/Counter clockwise to set Vset value. Vread should increase or decrease accordingly.If the regulator supports DFM, whilst Vset changes the valueshould also change.Pressing the control knob makes the WAI1000 go back to theprotocol selection screen.
12.6 Vread
Vset
DFM+ DFM-
12.6
C
S
LG S L F(C) (FR)
C FR
LIGCFR
L IG
There are two types of C terminal regulators H/L setpoint typeand PWM type the two methods for testing Vset/Vread aredescribed below.
WAI1000 Tester Quick Start Manual
Note: Small difference between the voltage is acceptable. What is important is the appropriate reactionof the alternator – increasing or decreasing the output voltage according to the required voltage andDFM value.
1- Terminal2- Read Voltage value3- Setting of regulator Voltage4- DFM
RLO TerminalSample plug:
Testing RLO terminal regulators
Main screen RLO
12.6 Vread
Vset
DFM+ DFM-
12.6
l
l
l
l
l
l
Speed up the alternator to about 1000 RPMWait for the WAI1000 to connect to the regulatorWhen information about the regulator shows up you can controlthe Voltage by rotating the control knobWhen changing the Vset value Vread should decrease orincrease accordinglyIf the regulator supports DFM while Vset changes the valueshould also changePressing the control knob makes the WAI1000 go back to theprotocol selection screen
L M
IG RLO
WAI1000 Tester Quick Start Manual EN
1- Terminal2- Read Voltage value3- Setting of regulator Voltage
PD TerminalSample plugs:
Testing PD terminal regulators
Main screen PD
12.6 Vread
Vset12.6
l
l
l
l
l
Speed up the alternator to about 1000 RPMWait for the WAI1000 to connect to the regulatorWhen information about the regulator shows up you can controlthe Voltage by rotating the control knobWhen changing the Vset value Vread should decrease orincrease accordinglyPressing the control knob makes the WAI1000 go back to theprotocol selection screen
PD1 P1 D
WAI1000 Tester Quick Start Manual
1- Terminal2- Read Voltage value3- Setting of regulator Voltage4- DFM
L-RVC TerminalSample plugs:
Testing L-RVC terminal regulators
Main screen L-RVC
12.6 Vread
Vset
DFM+ DFM-
12.6
l
l
l
l
l
l
Speed up the alternator to about 1000 RPMWait for the WAI1000 to connect to the regulatorWhen information about the regulator shows up you can controlthe Voltage by rotating the control knobWhen changing the Vset value Vread should decrease orincrease accordinglyIf the regulator supports DFM while Vset changes the valueshould also changePressing the control knob makes the WAI1000 go back to theprotocol selection screen
F LRVC DFM
WAI1000 Tester Quick Start Manual EN
1- Terminal2- Read Voltage value3- Setting of regulator Voltage4- DFM
SIG TerminalSample plugs:
Testing SIG terminal regulators
Main screen SIG
12.6 Vread
Vset
DFM+ DFM-
12.6
l
l
l
l
l
l
Speed up the alternator to about 1000 RPMWait for the WAI1000 to connect to the regulatorWhen information about the regulator shows up you can controlthe Voltage by rotating the control knobWhen changing the Vset value Vread should decrease orincrease accordinglyIf the regulator supports DFM while Vset changes the valueshould also changePressing the control knob makes the WAI1000 go back to theprotocol selection screen
FR SIG A
WAI1000 Tester Quick Start Manual
The DFM Monitor option enables DFM monitoring withoutcontrolling alternator
COM DFMBSS DFMDFM L L DFM
1- Terminal2- Read Voltage value3- Setting of regulator Voltage4- DFM
DFM MonitorSample plugs:
Testing DFM terminal regulators
Main screen DFM
12.6 Vread
Vset
DFM+ DFM-
12.6
l
WAI1000 Tester Quick Start Manual EN
1073-01-WAI-A5-TE-EN
WAI Corporate3300 Corporate WayMiramarFloridaFL 33025
Toll Free: 1-800-877-3340Fax: 1-800-948-6121
WAI Pennsylvania411 Eagleview BlvdSuite 100ExtonPA 19341
Toll Free: 1-800-877-3340Fax: 1-800-948-6121
WAI Los Angeles14820 Carmenita RoadNorwalkCaliforniaCA 90650
Toll Free: 1-800-877-3340Fax: 1-800-948-6121
WAI Allentown155 Nestle WaySuite 105, BreinigsvillePennsylvaniaPA 18031
Toll Free: 1-800-877-3340Fax: 1-800-948-6121
WAI Memphis480 Stateline RoadE SouthavenMississippiMS 38671
Toll Free: 1-800-877-3340Fax: 1-800-948-6121
WAI Canada535 Millway AvenueUnit 1VaughanOntarioL4K 3V4
Toll Free: 1-800-387-2807Fax: 416-740-5348
WAI Canada4711 Boul. CoutureMontréal (St-Léonard)QuébecH1R 3H7
Toll Free: 1-800-661-2962Fax: 514-328-1535
WAI United KingdomChristie Place, Durban RoadBognor RegisWest SussexPO22 9RT
Phone: +44 (0)1243 833 420Fax: +44 (0)1243 833 421
WAI EuropeKlappolder 2252665 MR BleiswijkThe Netherlands
Phone: +31 (0)10 524 1980Fax: +31 (0)10 524 1981
WAI BrazilAv. Coronel Marcos Konder1207-Sala7088.301-303Itajai-SC
Phone/Fax: (47)3046.1600
WAI PolandReslogisticPark Logistyczny RogoźnicaRogoźnica 306 A30-060 Głogów Małopolski(k.Rzeszowa)
Phone: +48 (0)17 77 25 805
WAI ChinaBuilding No. 32, 215 De Bao RdWai Gao Qiao Free Trade ZonePudong, Shanghai 200131Peoples Republic of China
Phone: 86 21 5048 2700Fax: 86 21 5048 2722
WAI IndiaIV/422West of Govt. BHSKodungallurKerala680664
Phone : +91 480 281 2161
Locations - Global
Locations - USA
WAI Headquarters