quickstart “basic” guidelines for model 9200 “full open

2
Anti-Grounding Plate TIME DELAY EXIT LOOP LMT REVERSE LOOP REV SENSE OPEN REV SENSE CLOSE 1 ON 2 3 4 1 ON 2 3 4 5 6 7 8 NC NO P8 P7 P6 4404-010 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 9410 9410 1 2 5 6 11 13A 13B 13E 25 16 17 U L1 L2/N B- B+ V W PE PE Mode EPM 1.0 PE SCM series basic I/O control 115 VAC Convenience Outlets DO NOT power up and cycle the operator until the “DIP-Switches” and the “Limit Switches” have been adjusted. Damage could occur to the gate and operator. T T T T T T T T T Opening direction OFF setting. Opening direction ON setting. Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. GATE OPERATOR MUST BE PROPERLY GROUNDED!! CAUTION High Voltage AC input power MUST MATCH the operator specifications or DAMAGE will occur and VOID the warranty! VERIFY Input AC power MATCHES your specific operator power BEFORE wiring! Electronic Box Power safety and opening devices that require 115 VAC power. Two 115 VAC Convenience Outlets Model 9200 is intended for installation only on sliding gates used for vehicles. Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual. See reverse side See reverse side to wire main terminal. With power OFF, push and hold the lock plate down where shown to adjust the Open and Close limit nuts. After adjusting the limit-nuts, be sure that the lock-plate is engaged in the slots on the limit-nuts to prevent them from rotating. The slow-down limits on all models but the 9210 will move up or down 3/4 inch. DO NOT remove the slow-down limit assembly from the 3/4 inch slot and re-attach it in the longer slot on the partial open adjustment rail to gain further adjustment. This will cause mechani- cal damage to the switch assembly when the operator is activated. Turn power ON and activate the gate operator. Re-adjust the limit nuts as necessary for full-open and full-close gate travel. After you are satisfied with the gate limit settings, the speed control knob can then be adjusted on all models but the 9210 to personal preference. 4” Min. Pad depth is determined by soil conditions and local building codes. Minimum depth is 18 inches. Reinforced concrete recommended. Concrete Pad Wire Mesh 3/4”conduit with sweeps recommended. Clear Plastic Electronic Box Cover 1 2 3 QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED ON THE PEDESTAL MOUNTING STAND 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Copyright 2013 DoorKing, Inc. All rights reserved. 9240-066-E-2-13 Plug-In Loop Detectors Not included - Refer to the Installation/Owner’s manual AND Loop Information Manual (available from www.dkaccess.com) for more information on loops and plug-in loop detectors. Important Note: DoorKing highly recommends that loops and loop detectors are installed with this slide gate operator. A loop detection system will preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. High Voltage Connection DIP-Switches Limit Switches 1. Opening Direction 2. ON 3. ON 4. OFF 5. OFF 6. OFF 7. OFF 8. OFF 1. OFF 2. OFF 3. OFF 4. OFF Auto-Close Timer Chassis Ground DANGER HIGH VOLTAGE! 1 ON 2 3 4 5 6 7 8 1 ON 2 3 4 SW 1 and 2 are Upside-Down on Circuit Board. 1 23 TIME DELAY A B D C C C B D 1 ft/s .5 ft/s 0 ft/s 2 ft/s 1.5 ft/s Limit LEDs Plug-In Loop Detector Plug-In Loop Detector Min Max Speed Push Push Lock-Plate Limit Nut Limit Nut 1 2 1 2 2 2 2 Slow-Down Limit Slow-Down Limit 1A 2A Partial Open Not Used 1 2 2A 1A Adjust 1 to 23 sec. 1 Limit Switch 2 Limit Switch Check polarity of Three Phase: Position the gate half way open. Give open command and while gate is opening, activate the appropriate limit switch with your finger. Gate should STOP. If it does not, activate the other limit switch. If this STOPS the gate, AC power wires must be changed (Reverse the connection of any 2 wires and re-check limits). Partial Open Adjustment Rail 208/230 VAC THREE Phase Chassis Ground High Voltage AC Input Wire Hot 115 VAC Output Hot Hot 208/230 VAC SINGLE Phase Chassis Ground High Voltage AC Input Wire Hot 115 VAC Output Hot Hot Use only two legs of the incoming 3-phase power. Chassis Ground High Voltage AC Input Wire Hot 115 VAC Output Neu 115 VAC SINGLE Phase White - Neutral Black - 115 VAC Hot Green - Chassis Ground SW 1 SW 2 A A A Operator MUST be parallel to gate! Chain brackets MUST align with idler wheels so chain stays parallel to gate! Remove the 3 locknuts inside the electronic box to swing box open. Gain Access Inside Operator Move the idler wheels to the lower position. Fits on All 9200 Models. Standard with 9230, 9235, 9240 and 9245 Models 1/2 Attach pedestal stand with sixteen (16) 1/2” x 3” sleeve anchors (not supplied) after concrete pad has been poured and has cured. Bolt operator to pedestal with hardware supplied in pedestal kit. Manual crank in stored position. Caution: Never attempt to manually operate the 9200 until you have verified that power has been shut-off. Connect Chain to the Gate Chain nut and chain bolt should not protrude past gate frame. The chain should sag no more than one (1) inch per 10 feet of travel. Do not over tighten the chain. Chain Nut Chain Bolt Option 2 Master Link Option 1 Gate Frame 1” Assemble Pedestal Mounting Stand Concrete Pad Dimensions, Pedestal Mounting Stand and Conduit Positions 1.75” 11.75” 4” 6.25” 4” 4” Concrete Pad Conduit Area Concrete pad MUST be level! Idler Wheels Gate Chain Bracket Conduit Chain Bracket Chain Bracket Idler Wheels Chain Configuration Concrete Pad Electronic Box DoorKing Part Number 9200-135 See instruction sheet with pedestal kit for assembly. Chain Tray Washer 12 Sets Washer Lockwasher Operator Base Plate Gate “Optional” Chain Tray Kit: Recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray and supporting brackets in 10 ft. sections to fit any length gate (DoorKing Part Number 2601-270, 10 Ft. section). See instruction sheet with chain tray kit for installation. Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels! 15.75” 11.75” 11.75” 10.5” 10.5” 10.5” 10.5” 1” 39.25” 22” Top Views Side Views Pedestal mounting stand MUST be level! Idler Wheels Speed Control Knob On all models but 9210.

Upload: others

Post on 01-Nov-2021

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN

Anti-Grounding Plate

TIME

DELAY

EXITLO

OP

LMT

REVERSE

LOO

P

REV SENSEO

PENREV SENSECLO

SE

1

ON

234 1

ON

2345678

NCNO

P8P7

P6

4404-010

20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

94109410

1 2 5 6 11 13A

13B

13E

25 16 17

U

L1 L2/N B- B+

V W PE PE

Mode

EPM 1.0 PE

SCM seriesbasic I/O control

115 VAC Convenience Outlets

DO NOT power up and cycle the operator until the “DIP-Switches” and the “Limit Switches” have been adjusted. Damage could occur to the gate and operator.

TTTTTTTTT

OpeningdirectionOFF setting.

OpeningdirectionON setting.

Tip: It is recommended that a surge suppressor be installed on the high voltage power lines.

GATE OPERATOR MUST BE PROPERLY GROUNDED!!

CAUTIONHigh Voltage AC input power MUST MATCH the operator specifications or DAMAGE will occur and VOID the warranty!

VERIFY Input AC power MATCHES yourspecific operator power BEFORE wiring!

EXITLO

OPLM

T

REVERSE

LOO

P

REV SENSECLO

SE

P8P7

P6

4404-010

1

2

4

3

1

2

4

3

1

2

4

3

Elect

roni

c Box

Power safety and opening devices that require 115 VAC power.

Two 115 VAC Convenience Outlets

Model 9200 is intended for installation only on sliding gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.

See reverse side

See reverse side to wire main terminal.

With power OFF, push and hold the lock plate down where shown to adjust the Open and Close limit nuts.After adjusting the limit-nuts, be sure that the lock-plate is engaged in the slots on the limit-nuts to prevent them from rotating.The slow-down limits on all models but the 9210 will move up or down 3/4 inch. DO NOT remove the slow-down limit assembly from the 3/4 inch slot and re-attach it in the longer slot on the partial open adjustment rail to gain further adjustment. This will cause mechani-cal damage to the switch assembly when the operator is activated.Turn power ON and activate the gate operator. Re-adjust the limit nuts as necessary for full-open and full-close gate travel. After you are satisfied with the gate limit settings, the speed control knob can then be adjusted on all models but the 9210 to personal preference.

4” Min.

Pad depth is determined by soil conditions and local building codes.Minimum depth is 18 inches. Reinforced concrete recommended.

Concrete PadWireMesh

3/4”conduit withsweeps recommended.

Clea

r Pla

stic

Ele

ctro

nic

Box

Cove

r

1

2

3

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED ON THE PEDESTAL MOUNTING STAND

120 Glasgow AvenueInglewood, California 90301

U.S.A.

Copyright 2013 DoorKing, Inc. All rights reserved. 9240-066-E-2-13

Plug-In Loop DetectorsNot included - Refer to the Installation/Owner’s manual AND Loop Information Manual (available from www.dkaccess.com) for more information on loops and plug-in loop detectors.Important Note: DoorKing highly recommends that loops and loop detectors are installed with this slide gate operator. A loop detection system will preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path.

High Voltage Connection

DIP-Switches

Limit Switches1. Opening Direction2. ON3. ON4. OFF5. OFF6. OFF7. OFF8. OFF

1. OFF2. OFF3. OFF4. OFF

Auto-Close Timer

ChassisGround

DANGERHIGH VOLTAGE!

1

ON

23456781

ON

234SW 1 and 2 are Upside-Down on Circuit Board.

1 23

TIME

DELAY

A

B

DC

C C

BD

1 ft/s

.5 ft/s

0 ft/s 2 ft/s

1.5 ft/s

Limit LEDs

Plug-In LoopDetector

Plug-In LoopDetector

Min MaxSpeed

PushPush

Lock-Plate

Limit Nut

Limit Nut

1

2

1

2222

Slow-Dow

n Limit

Slow-Dow

n Limit

1A

2A

Partial Open

Not Used

12 2A

1A

Adjust 1 to 23 sec.

1 Limit

Switch

2 Limit

Switch Check polarity of Three Phase: Position the gate half way open. Give open command and while gate is opening, activate the appropriate limit switch with your finger. Gate should STOP. If it does not, activate the other limit switch. If this STOPS the gate, AC power wires must be changed (Reverse the connection of any 2 wires and re-check limits).

Partial Open Adjustment Rail

208/230 VACTHREE Phase

ChassisGround

HighVoltage

AC InputWire

Hot

115 VAC Output

Hot Hot

208/230 VACSINGLE Phase

ChassisGround

HighVoltage

AC InputWire

Hot

115 VAC Output

Hot Hot

Use only two legs of the incoming 3-phase power.

ChassisGround

HighVoltage

AC InputWire

Hot

115 VAC Output

Neu

115 VACSINGLE Phase

White - NeutralBlack - 115 VAC HotGreen - Chassis Ground

SW 1SW 2

AA

AOperator MUST be parallel to gate!

Chain brackets MUST align with idler wheels so chain stays parallel to gate!

Remove the 3 locknuts inside the electronic box to swing box open.

Gain Access Inside Operator

Move the idler wheels to the lower position.

Fits on All 9200 Models.Standard with 9230, 9235, 9240 and 9245 Models

1/2

Attach pedestal stand with sixteen (16) 1/2” x 3” sleeve anchors (not supplied) after concrete pad has been poured and has cured.

Bolt operator to pedestal with

hardware supplied in pedestal kit.

Manualcrank instoredposition.

Caution: Never attempt to manually operate the 9200 until you have verified that power has been shut-off.

ConnectChain tothe Gate

Chain nut and chain bolt should not protrude past gate frame. The chain should sag no more than one (1) inch per 10 feet of travel. Do not over tighten the chain.

ChainNut

Chain Bolt

Option 2

Master Link

Option 1

Gate

Fram

e

1”

Assemble Pedestal Mounting Stand

Concrete Pad Dimensions,

Pedestal Mounting

Stand and Conduit

Positions

1.75”

11.75”

4”

6.25” 4”

4”

Concrete Pad

ConduitArea Concrete pad

MUST be level!

IdlerWheels

Gate

ChainBracket

Conduit

ChainBracket

ChainBracket

Idler Wheels

ChainConfiguration

Concrete Pad

Electronic Box

DoorKing

Part Number

9200-135

See instruction sheet with pedestal kit for assembly.

ChainTray

Washer

12 Sets

WasherLockwasher

Operator Base Plate

Gate

“Optional” Chain Tray Kit:Recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray and supporting brackets in 10 ft. sections to fit any length gate (DoorKing Part Number 2601-270,10 Ft. section). See instruction sheet with chain tray kit for installation.

Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels!

15.75”11.75”11.75”

10.5” 10.5”10.5” 10.5”

1”

39.25”

22”

TopViews

SideViews

Pedestal mounting stand MUST be level!

Idler Wheels

Speed Control KnobOn all models but 9210.

Page 2: QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN

SW 1 DIP-Switches (Right Hand Side)

SW 2 DIP-Switches (Left Hand Side)

NCNO

P7

20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Red Full Open

Green Close

White Com

Key Switch

Stand-AloneKeypad

Stand-AloneCard Reader

Telephone Entry

3-Button Control StationDoorKing ONLY

Functions ONLY during gate closing cycle.

Note: All stand-alone and telephone entry devices must use a separate power source.

Important: Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use.

“Optional” REVERSE GATEfor Closing Direction

Photo Sensors

#1-Com

#1-Com

#5 - Partial Open (See manual)

#4 - Full Open

ComTo #4 or #5

#2 or #5-Relay

250 mamp. max.#3-24 volt

#1-Relay Com

#2 or #5-Relay

#1-24 Volt Power Com

#3-24 Volt Power

4-Wire Radio Receiver

#2-Fully opens gate.

3-Wire Radio Receiver

Safety Opening Device

SW 1, switch 7: After photo sensor beam gets obstructed:

OFF Setting - REVERSES GATE.ON Setting - Stops gate then continues closing when gate is clear (Same function as UL 325 terminal #2).Note: The ON setting is used to help prevent tailgating but the photo sensor should be wired to the UL 325 terminal #2 when the “stop gate” function is desired, see manual for more information.

#5 Terminal Note: Any opening device connected to terminal #5 will open the gate to the partial open setting. Secondary entrapment protection devices will also open the gate to the partial open setting. If the Inherent Reverse Sensor gets activated during the close cycle, it will always fully open the gate.

1

ON

2345678

SW 1 is Upside-Down on Board

1

ON

2345678

SW 1 is Upside-Down on Board

Auxiliary CommonTerminal

Connect any common wire to these 2 terminals.

SW 1, Switch 3 MUST be ON except for dual operators or exit loop partial open applications.

Main Terminal

1

ON

2345678

1

ON

234 Switch Function Setting DescriptionSW 2 - Left 4 Switches

2

Spare4

1 Self-Test

Gate OpensUphill

3 Gate OpensDownhill

OFFON

Normal Setting. Normal gate operation.Self-test mode. Operator MUST be disconnected from gate to run self-test.

OFFON

Normal Setting. Normal gate operation.MUST be ON if gate opens UPHILL.

OFFON

Normal Setting. Normal gate operation.MUST be ON if gate opens DOWNHILL.

OFF Leave in the OFF position.

SW 1Upside-Down on Circuit Board.

SW 2Upside-Down on Circuit Board.

Exit Loop PortOutput

Full Open Input

Lower Configuration

Warn BeforeOperate

The output wired to terminal #4 becomes the output from the loop detector installed in the EXIT loop port. Plug-in loop detector required for “OFF” function. Normal Setting. Terminal #4 is a normal full open input for a single gate operator.

Reverses Gate

Stops Gate

Switch Function Setting DescriptionSW 1 - Right 8 Switches

OFFON

4-OFF4-OFF4-ON4-ON

5-OFF5-ON

5-OFF5-ON

Auto-CloseTimer

Relay Activationand

LED IndicatorLight Activation

2

1

3

4 and 5

7

8

OFFON

OFF

ON

Normal Setting. No sound.Internal alarm will sound before gate starts and throughout gate’s cycle.

Auto-close timer is OFF. Manual input required to close gate.Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.

6

Relay activates and LED is ON when the gate is fully open. Relay activates and LED is ON when the gate is not closed.Relay activates and LED is ON when the gate is opening and open. Relay activates and LED is ON when the gate is opening and closing.

Changes the direction the operator will open/close the gate. Opening direction

using ON setting.Opening directionusing OFF setting.

OFFON

Normal Setting. Timer will function normally.Opening gate will stop and begin to close as soon as all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the distance the gate has opened.

OFF

ON

Normal Setting. Input to terminal #6 and/or reverse loops will REVERSE gate during CLOSE cycle.Input to terminal #6 and/or reverse loops will STOP gate during CLOSE cycle.

Quick-CloseTimer Override

Jumper WireNeeded

See Manual

Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect.

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 - DIP-SWITCH AND WIRING REFERENCE

120 Glasgow AvenueInglewood, California 90301

U.S.A.

Model 9200 is intended for installation only on sliding gates used for vehicles.Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.