r c101 - epcdevplanstorage.blob.core.windows.net€¦ · new 3'-0" man gate -see detail ....

3
3 FIBER HANDHOLE 1 GRAVEL DRIVE DETAIL 2 GRAVEL YARD DETAIL 4 MAN GATE DETAIL EXISTING CHAINLINK FENCE LEGEND LEGEND NEW UNDERGROUND FIBER NEW UNDERGROUND ELECTRIC EXISTING UTILITY POLE SITE BENCHMARK EXISTING GRAVEL NEW GRAVEL EXISTING OVERHEAD ELECTRIC LINE 1. DIMENSIONS ARE TO THE EDGE OF CONCRETE, PAVING, OR FACE OF BLDG, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES. TAKE CARE TO PROTECT UTILITIES THAT ARE TO REMAIN. REPAIR DAMAGE ACCORDING TO LOCAL STANDARDS AND AT CONTRACTOR'S EXPENSE. COORDINATE ALL CONSTRUCTION WITH THE APPROPRIATE UTILITY COMPANY. 2. IN THE EVENT OF ANY DISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS ARE ENCOUNTERED DURING CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. 3. CONTRACTOR SHALL VERIFY EXISTING ELEVATIONS PRIOR TO BEGINNING WORK. 4. ALL DAMAGE TO EXISTING GRASS AREAS AS A RESULT OF NEW CONSTRUCTION SHALL BE RESEEDED AT THE CONTRACTOR'S EXPENSE. 5. SITE DEVELOPMENT PLAN IS BASED ON A PRE-CONSTRUCTION BOUDARY & TOPOGRAPHIC SURVEY PROVIDED BY WILDCAT SURVEYING, PROJECT NUMBER 176-05-2019. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW AND VERIFY THE SURVEY PRIOR TO BIDDING AND BEGINNING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL SURVEY INFORMATION PRESENTED, DEPICTED, OR DEFINED ON THE ARCHITECTURAL /SITE DOCUMENTS WITH THE CERTIFIED SURVEY OF THE PROPERTY. IN THE EVENT OF A COORDINATE OR TOPOGRAPHIC DISCREPANCY THE CERTIFIED SURVEY SHOULD ALWAYS TAKE PRECEDENCE. IN THE EVENT OF ANY DISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS ARE ENCOUNTERED DURING CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. 6. FINISH FLOOR ELEVATION OF NEW BUILDING EQUALS 6232.00'. 6232.00' = 100'-0" IN CONSTRUCTION DOCUMENTS. 7. COORDINATE SUBGRADE PREPARATION WITH GEOTECHNICAL INFORMATION. GEOTECHNICAL REPORT BY TERRACON. FOR MORE INFORMATION, CONTACT ROBERT HERNANDEZ AT (719) 572-7672. CONTRACTOR PRIOR TO COMMENCEMENT OF WORK SHALL OBTAIN IN WRITING THAT OLDCASTLE PRECAST ENGINEER OF RECORD HAS RECEIVED AND REVIEWED GEOTECHNICAL SURVEY AND RECOMMENDATIONS VERIFYING ADEQUACY OF PRECAST FOUNDATIONS UTILIZED FOR THIS PROJECT. 8. ALL ITEMS BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 9. GENERAL CONTRACTOR TO LOCATE ALL EXISTING INFRASTRUCTURE UTILITIES (PRIVATE AND PUBLIC) PRIOR TO ANY DIGGING. CONTRACTOR IS RESPONSIBLE FOR ALL DISRUPTIONS TO EXISTING SERVICES, UTILITIES ETC. AND TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE SAME. 10. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR & SUBCONTRACTOR TO COORDINATE THIS INSTALLATION OF ALL WORK WITHIN THE RIGHT OF WAY WITH COUNTY, STATE, AND LOCAL APPROVAL AND REVIEW AGENCIES. ALL DETAILS, MATERIALS AND PRODUCTS UTILIZED, SPECIFICATIONS, GRADES/CONTOURS, ETC. DEPICTED BY THE CONSTRUCTION DOCUMENTS SHALL BE REVIEWED WITH THE APPROVAL AGENCIES HAVING JURISDICTION BY THE CONTRACTOR(S) RESPONSIBLE FOR THE WORK PRIOR TO THE INSTALLATION OF ANY PORTION OF THE WORK. IF ANY DISCREPANCIES ARISE FROMTHE FINAL CONTRACTOR REVIEW WITH THE APPROVAL AGENCY HAVING JURISDICTION OCCURS, THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ITS REPRESENTATIVE AS DEFINED ON THE TITLE BORDER. 11. IT IS THE RESPONSIBILITY OF THE PRE-CAST FOUNDATION DESIGN ENGINEER TO VERIFY WITH GEOTECHNICAL ENGINEER THE ADEQUACY OF EXISTING SOILS TO ACCEPT BUILDING LOADS. 12.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IMMEDIATELY INFORM THE PROJECT MANAGER AND THE OWNER OF ANY OBSTRUCTIONS, ROCK FORMATIONS, OUTCROPPINGS ETC. THAT MAY IMPACT STRUCTURAL STABILITY OF THE BUILDING, FOUNDATIONS AND SITE INFRASTRUCTURE. THE PROJECT MANAGER/OWNER IS RESPONSIBLE TO CONTACT THE ARCHITECT AND OLDCASTLE STRUCTURAL ENGINEER UPON NOTIFICATIONS FORM THE CONTRACTOR. 13.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY AN "ON SITE" GEOTECHNICAL ENGINEER LICENSED (PE) IN THE STATE OF THE PROJECT LOCATION TO REVIEW EXISTING SOIL CONDITIONS AT THE TIME OF EXCAVATION FOR FOOTINGS/INFRASTRUCTURE TO RENDER OPINIONS, APPROVAL OR DECISIONS REGARDING PLACEMENT/ADEQUACY DESIGN OF PRECAST FOUNDATIONS INFRASTRUCTURE AND BUILDING. CONTACT PROJECT MANAGER AND ARCHITECT (JOINTLY OF ANY RECOMMENDATIONS AND/OR MODIFICATIONS REQUIRED OR OTHERWISE RENDERED OR RECOMMENDED BY THE LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER. 14. CONTRACTOR RESPONSIBLE TO CONTACT OLDCASTLE PRECAST FOUNDATION ENGINEER, TERRACON GEOTECHNICAL ENGINEER AND VERIFY ADEQUACY OF FOUNDATION DESIGN WITH THE SOILS FOUND ON THE SITE. TERRACON'S NET ALLOWABLE BEARING PRESSURE PER GEOTECHNICAL REPORT DATED 11.10.19 ARE 2500 PSF. CONTRACTOR SHALL EMPLOY LICENSED GEOTECHNICAL AT TIME OF SOIL EXCAVATION TO PERFORM ON SITE ANALYSIS AND CORRESPONDING RECOMMENDATIONS PRIOR TO PLACEMENT OF FOOTINGS AND BUILDING. 15. ALL FILL MATERIAL SHALL BE APPROVED QUALITY AND REVIEWED BY GEOTECHNICAL ENGINEER IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MEET AND EXCEED ALL COMPACTION STANDARDS PER THE GEOTECHNICAL AND ENGINEERS REPORT AND REQUIREMENTS . IN THE ABSENCE OF A GEOTECHNICAL REPORT THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK WHAT SO EVER. 16. THE PARTIES RESPONSIBLE FOR THIS PLAN HAVE FAMILIARIZED THEMSELVES WITH ALL CURRENT ACCESSIBILITY CRITERIA AND SPECIFICATIONS AND THE PROPOSED PLAN REFLECTS ALL SITE ELEMENTS REQUIRED BY THE APPLICABLE ADA DESIGN STANDARDS AND GUIDELINES AS PUBLISHED BY THE UNITED STATES DEPARTMENT OF JUSTICE. APPROVAL OF THIS PLAN BY EL PASO COUNTY DOES NOT ASSURE COMPLIANCE WITH THE ADA OR ANY REGULATIONS OR GUIDELINES ENACTED OR PROMULGATED UNDER OR WITH RESPECT TO SUCH LAWS. SITE LAYOUT GENERAL NOTES: EXISTING BARBED WIRE FENCE NEW CHAINLINK FENCE EXISTING UNDERGROUND FIBER EXISTING UNDERGROUND TELEPHONE CONTROL POINT PROPERTY POINT EXISTING UNDERGROUND ELECTRIC EXTERIOR LIGHTING LUMINARIE SCHEDULE DESCRIPTION WALL PACK LIGHT FIXTURE WITH INTEGRAL PHOTOCELL AND MOTION SENSOR MTD. BELOW BY BUILDING MANUFACTURER. MODEL LITHONIA LED-2-10A700/40K-SR2 -120-PE-XX MCGRAW EDISON 1ST-BO2-LED-EI-BL2 -XX-P120 TAG VOLTAGE LAMPS 120 VOLT LED 40W MOUNTING WALL 7'-0" ABOVE FINISH GRADE REMARKS INTEGRAL PHOTOCELL AND MOTION SNESOR MOUNTED BELOW -BY BUILDING MANUFACTURER A C101 AND DETAILS ENLARGED SITE PLAN ENLARGED SITE PLAN Know what's below. before you dig. Call R architects interiors . COLORADO SPRINGS, CO 80930 18304 HIGHWAY 94 DESIGN GROUP 15925 HARGRAY DRIVE NOBLESVILLE, INDIANA 46062 P: 833-348-3934 www.five9dg.com THIS IS AN ORIGINAL DESIGN, CREATED BY FIVE NINE DESIGN GROUP THE CONCEPTS, IDEAS, PLANS AND DETAILS ARE THE SOLE PROPERTY OF FIVE NINE DESIGN GROUP. NONE OF THE CONCEPTS, IDEAS, PLANS OR DETAILS SHALL BE COPIED, USED BY, OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN PERMISSION OF FIVE NINE DESIGN GROUP. WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND FIVE NINE DESIGN GROUP MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS.

Upload: others

Post on 20-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R C101 - epcdevplanstorage.blob.core.windows.net€¦ · new 3'-0" man gate -see detail . precast generator pad furnished and installed by building manufacturer -see manufacturer

3 FIBER HANDHOLE1

GRAVEL

DRIVE DETAIL2 GRAVEL YARD DETAIL4 MAN GATE DETAIL

EXISTING CHAINLINK FENCE

LEGENDLEGEND

NEW UNDERGROUND FIBER

NEW UNDERGROUND ELECTRIC

EXISTING UTILITY POLE

SITE BENCHMARK

EXISTING GRAVEL

NEW GRAVEL

EXISTING OVERHEAD ELECTRIC LINE

1. DIMENSIONS ARE TO THE EDGE OF CONCRETE, PAVING, OR FACE OF BLDG, UNLESS OTHERWISE NOTED. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES. TAKE CARE TO PROTECT UTILITIES THAT ARE TOREMAIN. REPAIR DAMAGE ACCORDING TO LOCAL STANDARDS AND AT CONTRACTOR'S EXPENSE. COORDINATE ALLCONSTRUCTION WITH THE APPROPRIATE UTILITY COMPANY.

2. IN THE EVENT OF ANY DISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS AREENCOUNTERED DURING CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFOREPROCEEDING WITH THE WORK.

3. CONTRACTOR SHALL VERIFY EXISTING ELEVATIONS PRIOR TO BEGINNING WORK.

4. ALL DAMAGE TO EXISTING GRASS AREAS AS A RESULT OF NEW CONSTRUCTION SHALL BE RESEEDED AT THECONTRACTOR'S EXPENSE.

5. SITE DEVELOPMENT PLAN IS BASED ON A PRE-CONSTRUCTION BOUDARY & TOPOGRAPHIC SURVEY PROVIDED BYWILDCAT SURVEYING, PROJECT NUMBER 176-05-2019. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ANDVERIFY THE SURVEY PRIOR TO BIDDING AND BEGINNING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO VERIFY ALL SURVEY INFORMATION PRESENTED, DEPICTED, OR DEFINED ON THE ARCHITECTURAL/SITE DOCUMENTS WITH THE CERTIFIED SURVEY OF THE PROPERTY. IN THE EVENT OF A COORDINATE ORTOPOGRAPHIC DISCREPANCY THE CERTIFIED SURVEY SHOULD ALWAYS TAKE PRECEDENCE. IN THE EVENT OF ANYDISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS ARE ENCOUNTERED DURINGCONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK.

6. FINISH FLOOR ELEVATION OF NEW BUILDING EQUALS 6232.00'. 6232.00' = 100'-0" IN CONSTRUCTION DOCUMENTS.

7. COORDINATE SUBGRADE PREPARATION WITH GEOTECHNICAL INFORMATION. GEOTECHNICAL REPORT BY TERRACON.FOR MORE INFORMATION, CONTACT ROBERT HERNANDEZ AT (719) 572-7672. CONTRACTOR PRIOR TO COMMENCEMENTOF WORK SHALL OBTAIN IN WRITING THAT OLDCASTLE PRECAST ENGINEER OF RECORD HAS RECEIVED AND REVIEWEDGEOTECHNICAL SURVEY AND RECOMMENDATIONS VERIFYING ADEQUACY OF PRECAST FOUNDATIONS UTILIZED FORTHIS PROJECT.

8. ALL ITEMS BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.

9. GENERAL CONTRACTOR TO LOCATE ALL EXISTING INFRASTRUCTURE UTILITIES (PRIVATE AND PUBLIC) PRIOR TO ANYDIGGING. CONTRACTOR IS RESPONSIBLE FOR ALL DISRUPTIONS TO EXISTING SERVICES, UTILITIES ETC. AND TAKE ALLPRECAUTIONS NECESSARY TO PROTECT THE SAME.

10. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR & SUBCONTRACTOR TO COORDINATE THIS INSTALLATION OFALL WORK WITHIN THE RIGHT OF WAY WITH COUNTY, STATE, AND LOCAL APPROVAL AND REVIEW AGENCIES. ALLDETAILS, MATERIALS AND PRODUCTS UTILIZED, SPECIFICATIONS, GRADES/CONTOURS, ETC. DEPICTED BY THECONSTRUCTION DOCUMENTS SHALL BE REVIEWED WITH THE APPROVAL AGENCIES HAVING JURISDICTION BY THECONTRACTOR(S) RESPONSIBLE FOR THE WORK PRIOR TO THE INSTALLATION OF ANY PORTION OF THE WORK. IF ANYDISCREPANCIES ARISE FROMTHE FINAL CONTRACTOR REVIEW WITH THE APPROVAL AGENCY HAVING JURISDICTIONOCCURS, THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ITS REPRESENTATIVE AS DEFINED ON THE TITLEBORDER.

11. IT IS THE RESPONSIBILITY OF THE PRE-CAST FOUNDATION DESIGN ENGINEER TO VERIFY WITH GEOTECHNICALENGINEER THE ADEQUACY OF EXISTING SOILS TO ACCEPT BUILDING LOADS.

12.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IMMEDIATELY INFORM THE PROJECT MANAGER AND THE OWNEROF ANY OBSTRUCTIONS, ROCK FORMATIONS, OUTCROPPINGS ETC. THAT MAY IMPACT STRUCTURAL STABILITY OF THEBUILDING, FOUNDATIONS AND SITE INFRASTRUCTURE. THE PROJECT MANAGER/OWNER IS RESPONSIBLE TO CONTACTTHE ARCHITECT AND OLDCASTLE STRUCTURAL ENGINEER UPON NOTIFICATIONS FORM THE CONTRACTOR.

13.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY AN "ON SITE" GEOTECHNICAL ENGINEER LICENSED (PE) INTHE STATE OF THE PROJECT LOCATION TO REVIEW EXISTING SOIL CONDITIONS AT THE TIME OF EXCAVATION FORFOOTINGS/INFRASTRUCTURE TO RENDER OPINIONS, APPROVAL OR DECISIONS REGARDING PLACEMENT/ADEQUACYDESIGN OF PRECAST FOUNDATIONS INFRASTRUCTURE AND BUILDING. CONTACT PROJECT MANAGER AND ARCHITECT(JOINTLY OF ANY RECOMMENDATIONS AND/OR MODIFICATIONS REQUIRED OR OTHERWISE RENDERED ORRECOMMENDED BY THE LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER.

14.CONTRACTOR RESPONSIBLE TO CONTACT OLDCASTLE PRECAST FOUNDATION ENGINEER, TERRACON GEOTECHNICALENGINEER AND VERIFY ADEQUACY OF FOUNDATION DESIGN WITH THE SOILS FOUND ON THE SITE. TERRACON'S NETALLOWABLE BEARING PRESSURE PER GEOTECHNICAL REPORT DATED 11.10.19 ARE 2500 PSF. CONTRACTOR SHALLEMPLOY LICENSED GEOTECHNICAL AT TIME OF SOIL EXCAVATION TO PERFORM ON SITE ANALYSIS ANDCORRESPONDING RECOMMENDATIONS PRIOR TO PLACEMENT OF FOOTINGS AND BUILDING.

15. ALL FILL MATERIAL SHALL BE APPROVED QUALITY AND REVIEWED BY GEOTECHNICAL ENGINEER IT IS THERESPONSIBILITY OF THE CONTRACTOR TO MEET AND EXCEED ALL COMPACTION STANDARDS PER THE GEOTECHNICALAND ENGINEERS REPORT AND REQUIREMENTS . IN THE ABSENCE OF A GEOTECHNICAL REPORT THE CONTRACTORSHALL IMMEDIATELY CONTACT THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK WHAT SO EVER.

16.THE PARTIES RESPONSIBLE FOR THIS PLAN HAVE FAMILIARIZED THEMSELVES WITH ALL CURRENT ACCESSIBILITYCRITERIA AND SPECIFICATIONS AND THE PROPOSED PLAN REFLECTS ALL SITE ELEMENTS REQUIRED BY THEAPPLICABLE ADA DESIGN STANDARDS AND GUIDELINES AS PUBLISHED BY THE UNITED STATES DEPARTMENT OFJUSTICE. APPROVAL OF THIS PLAN BY EL PASO COUNTY DOES NOT ASSURE COMPLIANCE WITH THE ADA OR ANYREGULATIONS OR GUIDELINES ENACTED OR PROMULGATED UNDER OR WITH RESPECT TO SUCH LAWS.

SITE LAYOUT GENERAL NOTES:

EXISTING BARBED WIRE FENCE

NEW CHAINLINK FENCE

EXISTING UNDERGROUND FIBER

EXISTING UNDERGROUND TELEPHONE

CONTROL POINT

PROPERTY POINT

EXISTING UNDERGROUND ELECTRIC

EXTERIOR LIGHTING LUMINARIE SCHEDULE

DESCRIPTION

WALL PACK LIGHTFIXTURE WITHINTEGRAL PHOTOCELLAND MOTION SENSORMTD. BELOW BYBUILDINGMANUFACTURER.

MODEL

LITHONIALED-2-10A700/40K-SR2-120-PE-XXMCGRAW EDISON1ST-BO2-LED-EI-BL2-XX-P120

TAG VOLTAGE LAMPS

120 VOLT LED 40W

MOUNTING

WALL7'-0" ABOVEFINISH GRADE

REMARKS

INTEGRALPHOTOCELL ANDMOTION SNESORMOUNTED BELOW -BYBUILDINGMANUFACTURER

A

C101

AND DETAILS

ENLARGED SITE PLAN

ENLARGED SITE PLAN

Know what's below.before you dig.Call

R

architects interiors.

CO

LO

RA

DO

SP

RIN

GS

, C

O 8

0930

18304 H

IGH

WA

Y 9

4

DESIGN GROUP

15925 HARGRAY DRIVE NOBLESVILLE, INDIANA 46062

P: 833-348-3934www.five9dg.com

THIS IS AN ORIGINAL DESIGN, CREATED BY FIVE NINE DESIGN GROUP THECONCEPTS, IDEAS, PLANS AND DETAILS ARE THE SOLE PROPERTY OFFIVE NINE DESIGN GROUP. NONE OF THE CONCEPTS, IDEAS, PLANS ORDETAILS SHALL BE COPIED, USED BY, OR DISCLOSED TO ANY PERSON,FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE PRIORWRITTEN PERMISSION OF FIVE NINE DESIGN GROUP. WRITTENDIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALEDIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FORALL DIMENSIONS AND CONDITIONS ON THE JOB AND FIVE NINE DESIGNGROUP MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONSAND CONDITIONS SHOWN ON THESE DRAWINGS.

AutoCAD SHX Text
NEW CHAINLINK FENCE SEE SHEET C200
AutoCAD SHX Text
EXISTING GRAVEL DRIVE
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
PP
AutoCAD SHX Text
Breakline
AutoCAD SHX Text
Book 1
AutoCAD SHX Text
301
AutoCAD SHX Text
T_Property Pin
AutoCAD SHX Text
Property Pin
AutoCAD SHX Text
TRUE
AutoCAD SHX Text
PP
AutoCAD SHX Text
Breakline
AutoCAD SHX Text
Book 1
AutoCAD SHX Text
302
AutoCAD SHX Text
T_Property Pin
AutoCAD SHX Text
Property Pin
AutoCAD SHX Text
TRUE
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
REMOVE SECTION OF FENCE
AutoCAD SHX Text
P.O.B. LEASE PARCEL 1 FOUND 1.25" RED PLASTIC CAP, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968 (N37°55'08"W - 194.30 FROM P.O.C.)
AutoCAD SHX Text
LEASE PARCEL 2
AutoCAD SHX Text
EXISTING GENERATOR
AutoCAD SHX Text
BREAKER BOX
AutoCAD SHX Text
EXISTING BARBED WIRE FENCE
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAP, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAB, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968
AutoCAD SHX Text
CONTROL POINT 1 N: 1367950.58 E: 3288036.98 EL 6225.71 SITE BENCHMARK
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAB, ON 5/8" REBAR, DOWN 0.3', STAMPED PLS 25968
AutoCAD SHX Text
LEASE AREA N89°25'34"E - 150.16.00' (M) 150.00' (R)
AutoCAD SHX Text
LEASE AREA N08°08'20"W - 149.93'(M) 150.00(R)
AutoCAD SHX Text
EXISTING GATES
AutoCAD SHX Text
EXISTING CHAIN-LINK FENCE
AutoCAD SHX Text
14'-0"
AutoCAD SHX Text
14'-0"
AutoCAD SHX Text
14'-0"
AutoCAD SHX Text
NEW GRAVEL DRIVE SEE DETAIL
AutoCAD SHX Text
(1) FIBER HANDHOLE BY OWNWER. G.C. TO STUB OUT (2) 2" PVC CONDUITS TO 5'-0" BEYOND FENCE. -SEE DETAIL
AutoCAD SHX Text
(1) FIBER HANDHOLE BY OWNWER. G.C. TO STUB OUT (2) 2" PVC CONDUITS TO 5'-0" BEYOND FENCE. -SEE DETAIL
AutoCAD SHX Text
NEW 3'-0" MAN GATE -SEE DETAIL
AutoCAD SHX Text
PRECAST GENERATOR PAD FURNISHED AND INSTALLED BY BUILDING MANUFACTURER -SEE MANUFACTURER DRAWINGS.
AutoCAD SHX Text
GENERATOR SET AND BELLY FUEL TANK FURNISHED BY OWNER AND INSTALLED BY G.C. -SEE MANUFACTURER DRAWINGS.
AutoCAD SHX Text
PVC CONDUITS FOR POWER AND TELEMETRY -SEE ELECTRICAL DRAWINGS.
AutoCAD SHX Text
R50'-0"
AutoCAD SHX Text
R5'-0"
AutoCAD SHX Text
R8'-0"
AutoCAD SHX Text
EXISTING TRANSFORMER AND METER
AutoCAD SHX Text
NEW FIBER BY OWNER
AutoCAD SHX Text
NEW FIBER BY OWNER
AutoCAD SHX Text
NEW UNDERGROUND ELECTRIC FURNISHED AND INSTALLED BY UTILITY SEE ELECTRICAL FOR ADDITIONAL INFORMATION..
AutoCAD SHX Text
ZAYO BLDG ONE-STORY PRECAST BLDG - 420 SQ. FT. BLDG HT. 11'-1" FF ELEV = 6232.00'
AutoCAD SHX Text
PRECAST CONCRETE STOOPS FURNISHED AND INSTALLED BY BUILDING MANUFACTURER - SEE MFG. DRAWINGS. PREPARE BASE PER GEOTECHNICAL REPORT
AutoCAD SHX Text
NEW GRAVEL YARD EXTEND 1'-0" BEYOND FENCE SEE DETAIL
AutoCAD SHX Text
EXISTING BLDG 2 213 SF
AutoCAD SHX Text
EXISTING BLDG 1 213 SF
AutoCAD SHX Text
EXISTING BLDG 5 117 SF
AutoCAD SHX Text
EXISTING BLDG 3 213 SF
AutoCAD SHX Text
EXISTING BLDG 4 240 SF
AutoCAD SHX Text
LEASE AREA S89°31'17"W - 150.00' (M)(R)
AutoCAD SHX Text
LEASE AREA S08°04'02"E - 150.15'(M) 150.00(R)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C101
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
WARNING TAPE, TYPICAL
AutoCAD SHX Text
FINISH GRADE - SEE PLAN
AutoCAD SHX Text
(2) 4" PVC CONDUITS BY G.C. (SEE PLAN FOR ROUTE) - SEE NOTE #9 E102 FOR DETAILS
AutoCAD SHX Text
G.C. TO PROVIDE 8'-0" LG. GROUNDING ROD W/ CLAMP
AutoCAD SHX Text
FIBER & SPLICE BY OTHERS
AutoCAD SHX Text
HANDHOLE - PROVIDE "ELECTRI-GLASS" MODEL HH2436-H5-CO WITH AASHTO H10-44 TRAFFIC-RATED LID
AutoCAD SHX Text
(2) 4" PVC CONDUITS BY G.C.
AutoCAD SHX Text
EXISTING FENCE
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
PROVIDE CAP ON CONDUITS
AutoCAD SHX Text
6" OF CRUSHED STONE OVER TENSAR BX-1200 OR EQUIVALENT BI-AXIAL GEOGRID - SEE GEOTECHNICAL REPORT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C101
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
PREPARE SUBGRADE PER GEO-TECHNICAL REPORT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
4" WELL GRADED CRUSHED STONE
AutoCAD SHX Text
WEED BARRIER: 5oz NEEDLE PUNCHED WOVEN POLYPROPYLENE, BLACK IN COLOR, WITH SEAMS LAPPED 3" MINIMUM AND SEAMS PER MANUFACTURER RECOMMENDATIONS
AutoCAD SHX Text
EXISTING SOIL AT GRADE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C101
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
PREPARE SUBGRADE PER GEO-TECHNICAL REPORT
AutoCAD SHX Text
REFERENCE SHEET C200 FOR DIMENSIONS AND POST SIZES
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C101
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
HEAVY DUTY HINGES
AutoCAD SHX Text
LOCKABLE LATCH
AutoCAD SHX Text
PP
AutoCAD SHX Text
61C101.DWG
AutoCAD SHX Text
REA
AutoCAD SHX Text
BSH
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1" = 10'-0"
AutoCAD SHX Text
NOTE: ARCHITECTURAL, ELECTRICAL, AND MECHANICAL PLANS ARE ORIENTED DIFFERENTLY THAN SITE PLAN. PLEASE NOTE NORTH ARROW ON EACH PLAN SHEET FOR PROPER ORIENTATION.
AutoCAD SHX Text
0'
AutoCAD SHX Text
5'
AutoCAD SHX Text
10'
AutoCAD SHX Text
20'
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
CERTIFICATION:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ISSUES
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
18061
AutoCAD SHX Text
ARCHITECT OF RECORD
AutoCAD SHX Text
3-18-20 ISSUED FOR PERMITS
Page 2: R C101 - epcdevplanstorage.blob.core.windows.net€¦ · new 3'-0" man gate -see detail . precast generator pad furnished and installed by building manufacturer -see manufacturer

6231

623

0

6231.98

6231.98

6231.87

6231.98

6231.98

6231.87

5331.30

5331.256231.30

6231.25

EXISTING CHAINLINK FENCE

LEGENDLEGEND

NEW UNDERGROUND FIBER

NEW UNDERGROUND ELECTRIC

EXISTING UTILITY POLE

SITE BENCHMARK

EXISTING GRAVEL

NEW GRAVEL

EXISTING OVERHEAD ELECTRIC LINE

1. DIMENSIONS ARE TO THE EDGE OF CONCRETE, PAVING, OR FACE OF BLDG, UNLESS OTHERWISE NOTED. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES. TAKE CARE TO PROTECT UTILITIES THAT ARE TOREMAIN. REPAIR DAMAGE ACCORDING TO LOCAL STANDARDS AND AT CONTRACTOR'S EXPENSE. COORDINATE ALLCONSTRUCTION WITH THE APPROPRIATE UTILITY COMPANY.

2. IN THE EVENT OF ANY DISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS AREENCOUNTERED DURING CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFOREPROCEEDING WITH THE WORK.

3. CONTRACTOR SHALL VERIFY EXISTING ELEVATIONS PRIOR TO BEGINNING WORK.

4. ALL DAMAGE TO EXISTING GRASS AREAS AS A RESULT OF NEW CONSTRUCTION SHALL BE RESEEDED AT THECONTRACTOR'S EXPENSE.

5. SITE DEVELOPMENT PLAN IS BASED ON A PRE-CONSTRUCTION BOUDARY & TOPOGRAPHIC SURVEY PROVIDED BYWILDCAT SURVEYING, PROJECT NUMBER 176-05-2019. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ANDVERIFY THE SURVEY PRIOR TO BIDDING AND BEGINNING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO VERIFY ALL SURVEY INFORMATION PRESENTED, DEPICTED, OR DEFINED ON THE ARCHITECTURAL/SITE DOCUMENTS WITH THE CERTIFIED SURVEY OF THE PROPERTY. IN THE EVENT OF A COORDINATE ORTOPOGRAPHIC DISCREPANCY THE CERTIFIED SURVEY SHOULD ALWAYS TAKE PRECEDENCE. IN THE EVENT OF ANYDISCREPANCIES AND/OR ERRORS FOUND IN THE DRAWINGS OR IF PROBLEMS ARE ENCOUNTERED DURINGCONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK.

6. FINISH FLOOR ELEVATION OF NEW BUILDING EQUALS 6232.00'. 6232.00' = 100'-0" IN CONSTRUCTION DOCUMENTS.

7. COORDINATE SUBGRADE PREPARATION WITH GEOTECHNICAL INFORMATION. GEOTECHNICAL REPORT BY TERRACON.FOR MORE INFORMATION, CONTACT ROBERT HERNANDEZ AT (719) 572-7672. CONTRACTOR PRIOR TO COMMENCEMENTOF WORK SHALL OBTAIN IN WRITING THAT OLDCASTLE PRECAST ENGINEER OF RECORD HAS RECEIVED AND REVIEWEDGEOTECHNICAL SURVEY AND RECOMMENDATIONS VERIFYING ADEQUACY OF PRECAST FOUNDATIONS UTILIZED FORTHIS PROJECT.

8. ALL ITEMS BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.

9. GENERAL CONTRACTOR TO LOCATE ALL EXISTING INFRASTRUCTURE UTILITIES (PRIVATE AND PUBLIC) PRIOR TO ANYDIGGING. CONTRACTOR IS RESPONSIBLE FOR ALL DISRUPTIONS TO EXISTING SERVICES, UTILITIES ETC. AND TAKE ALLPRECAUTIONS NECESSARY TO PROTECT THE SAME.

10. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR & SUBCONTRACTOR TO COORDINATE THIS INSTALLATION OFALL WORK WITHIN THE RIGHT OF WAY WITH COUNTY, STATE, AND LOCAL APPROVAL AND REVIEW AGENCIES. ALLDETAILS, MATERIALS AND PRODUCTS UTILIZED, SPECIFICATIONS, GRADES/CONTOURS, ETC. DEPICTED BY THECONSTRUCTION DOCUMENTS SHALL BE REVIEWED WITH THE APPROVAL AGENCIES HAVING JURISDICTION BY THECONTRACTOR(S) RESPONSIBLE FOR THE WORK PRIOR TO THE INSTALLATION OF ANY PORTION OF THE WORK. IF ANYDISCREPANCIES ARISE FROMTHE FINAL CONTRACTOR REVIEW WITH THE APPROVAL AGENCY HAVING JURISDICTIONOCCURS, THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ITS REPRESENTATIVE AS DEFINED ON THE TITLEBORDER.

11. IT IS THE RESPONSIBILITY OF THE PRE-CAST FOUNDATION DESIGN ENGINEER TO VERIFY WITH GEOTECHNICALENGINEER THE ADEQUACY OF EXISTING SOILS TO ACCEPT BUILDING LOADS.

12.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IMMEDIATELY INFORM THE PROJECT MANAGER AND THE OWNEROF ANY OBSTRUCTIONS, ROCK FORMATIONS, OUTCROPPINGS ETC. THAT MAY IMPACT STRUCTURAL STABILITY OF THEBUILDING, FOUNDATIONS AND SITE INFRASTRUCTURE. THE PROJECT MANAGER/OWNER IS RESPONSIBLE TO CONTACTTHE ARCHITECT AND OLDCASTLE STRUCTURAL ENGINEER UPON NOTIFICATIONS FORM THE CONTRACTOR.

13.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY AN "ON SITE" GEOTECHNICAL ENGINEER LICENSED (PE) INTHE STATE OF THE PROJECT LOCATION TO REVIEW EXISTING SOIL CONDITIONS AT THE TIME OF EXCAVATION FORFOOTINGS/INFRASTRUCTURE TO RENDER OPINIONS, APPROVAL OR DECISIONS REGARDING PLACEMENT/ADEQUACYDESIGN OF PRECAST FOUNDATIONS INFRASTRUCTURE AND BUILDING. CONTACT PROJECT MANAGER AND ARCHITECT(JOINTLY OF ANY RECOMMENDATIONS AND/OR MODIFICATIONS REQUIRED OR OTHERWISE RENDERED ORRECOMMENDED BY THE LICENSED PROFESSIONAL GEOTECHNICAL ENGINEER.

14.CONTRACTOR RESPONSIBLE TO CONTACT OLDCASTLE PRECAST FOUNDATION ENGINEER, TERRACON GEOTECHNICALENGINEER AND VERIFY ADEQUACY OF FOUNDATION DESIGN WITH THE SOILS FOUND ON THE SITE. TERRACON'S NETALLOWABLE BEARING PRESSURE PER GEOTECHNICAL REPORT DATED 11.10.19 ARE 2500 PSF. CONTRACTOR SHALLEMPLOY LICENSED GEOTECHNICAL AT TIME OF SOIL EXCAVATION TO PERFORM ON SITE ANALYSIS ANDCORRESPONDING RECOMMENDATIONS PRIOR TO PLACEMENT OF FOOTINGS AND BUILDING.

15. ALL FILL MATERIAL SHALL BE APPROVED QUALITY AND REVIEWED BY GEOTECHNICAL ENGINEER IT IS THERESPONSIBILITY OF THE CONTRACTOR TO MEET AND EXCEED ALL COMPACTION STANDARDS PER THE GEOTECHNICALAND ENGINEERS REPORT AND REQUIREMENTS . IN THE ABSENCE OF A GEOTECHNICAL REPORT THE CONTRACTORSHALL IMMEDIATELY CONTACT THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK WHAT SO EVER.

16.THE PARTIES RESPONSIBLE FOR THIS PLAN HAVE FAMILIARIZED THEMSELVES WITH ALL CURRENT ACCESSIBILITYCRITERIA AND SPECIFICATIONS AND THE PROPOSED PLAN REFLECTS ALL SITE ELEMENTS REQUIRED BY THEAPPLICABLE ADA DESIGN STANDARDS AND GUIDELINES AS PUBLISHED BY THE UNITED STATES DEPARTMENT OFJUSTICE. APPROVAL OF THIS PLAN BY EL PASO COUNTY DOES NOT ASSURE COMPLIANCE WITH THE ADA OR ANYREGULATIONS OR GUIDELINES ENACTED OR PROMULGATED UNDER OR WITH RESPECT TO SUCH LAWS.

SITE LAYOUT GENERAL NOTES:

EXISTING BARBED WIRE FENCE

NEW CHAINLINK FENCE

EXISTING UNDERGROUND FIBER

EXISTING UNDERGROUND TELEPHONE

CONTROL POINT

PROPERTY POINT

EXISTING UNDERGROUND ELECTRIC

C102

GRADING PLAN

GRADING PLAN

Know what's below.before you dig.Call

R

architects interiors.

CO

LO

RA

DO

SP

RIN

GS

, C

O 8

0930

18304 H

IGH

WA

Y 9

4

DESIGN GROUP

15925 HARGRAY DRIVE NOBLESVILLE, INDIANA 46062

P: 833-348-3934www.five9dg.com

THIS IS AN ORIGINAL DESIGN, CREATED BY FIVE NINE DESIGN GROUP THECONCEPTS, IDEAS, PLANS AND DETAILS ARE THE SOLE PROPERTY OFFIVE NINE DESIGN GROUP. NONE OF THE CONCEPTS, IDEAS, PLANS ORDETAILS SHALL BE COPIED, USED BY, OR DISCLOSED TO ANY PERSON,FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE PRIORWRITTEN PERMISSION OF FIVE NINE DESIGN GROUP. WRITTENDIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALEDIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FORALL DIMENSIONS AND CONDITIONS ON THE JOB AND FIVE NINE DESIGNGROUP MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONSAND CONDITIONS SHOWN ON THESE DRAWINGS.

SITE

AutoCAD SHX Text
ZAYO BLDG ONE-STORY PRECAST BLDG - 420 SQ. FT. BLDG HT. 11'-1" FF ELEV = 6232.00'
AutoCAD SHX Text
EXISTING GRAVEL DRIVE
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
PP
AutoCAD SHX Text
Breakline
AutoCAD SHX Text
Book 1
AutoCAD SHX Text
301
AutoCAD SHX Text
T_Property Pin
AutoCAD SHX Text
Property Pin
AutoCAD SHX Text
TRUE
AutoCAD SHX Text
PP
AutoCAD SHX Text
Breakline
AutoCAD SHX Text
Book 1
AutoCAD SHX Text
302
AutoCAD SHX Text
T_Property Pin
AutoCAD SHX Text
Property Pin
AutoCAD SHX Text
TRUE
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
6229
AutoCAD SHX Text
6230
AutoCAD SHX Text
6231
AutoCAD SHX Text
6232
AutoCAD SHX Text
6233
AutoCAD SHX Text
6228
AutoCAD SHX Text
6227
AutoCAD SHX Text
6226
AutoCAD SHX Text
6225
AutoCAD SHX Text
REMOVE SECTION OF FENCE
AutoCAD SHX Text
P.O.B. LEASE PARCEL 1 FOUND 1.25" RED PLASTIC CAP, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968 (N37°55'08"W - 194.30 FROM P.O.C.)
AutoCAD SHX Text
LEASE PARCEL 2
AutoCAD SHX Text
EXISTING GENERATOR
AutoCAD SHX Text
BREAKER BOX
AutoCAD SHX Text
EXISTING BARBED WIRE FENCE
AutoCAD SHX Text
PROPERTY LINE
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAP, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAB, ON 5/8" REBAR, FLUSH WITH SURFACE, STAMPED PLS 25968
AutoCAD SHX Text
CONTROL POINT 1 N: 1367950.58 E: 3288036.98 EL 6225.71 SITE BENCHMARK
AutoCAD SHX Text
FOUND 1.25" RED PLASTIC CAB, ON 5/8" REBAR, DOWN 0.3', STAMPED PLS 25968
AutoCAD SHX Text
LEASE AREA N89°25'34"E - 150.16.00' (M) 150.00' (R)
AutoCAD SHX Text
LEASE AREA N08°08'20"W - 149.93'(M) 150.00(R)
AutoCAD SHX Text
EXISTING GATES
AutoCAD SHX Text
EXISTING CHAIN-LINK FENCE
AutoCAD SHX Text
(1) FIBER HANDHOLE BY OWNWER. G.C. TO STUB OUT (2) 2" PVC CONDUITS TO 5'-0" BEYOND FENCE. -SEE DETAIL
AutoCAD SHX Text
EXISTING TRANSFORMER AND METER
AutoCAD SHX Text
NEW FIBER BY OWNER
AutoCAD SHX Text
NEW FIBER BY OWNER
AutoCAD SHX Text
+6231.25
AutoCAD SHX Text
+6231.25
AutoCAD SHX Text
EXISTING BLDG 2 213 SF
AutoCAD SHX Text
EXISTING BLDG 1 213 SF
AutoCAD SHX Text
EXISTING BLDG 5 117 SF
AutoCAD SHX Text
EXISTING BLDG 3 213 SF
AutoCAD SHX Text
EXISTING BLDG 4 240 SF
AutoCAD SHX Text
LEASE AREA S89°31'17"W - 150.00' (M)(R)
AutoCAD SHX Text
LEASE AREA S08°04'02"E - 150.15'(M) 150.00(R)
AutoCAD SHX Text
PP
AutoCAD SHX Text
61C102.DWG
AutoCAD SHX Text
REA
AutoCAD SHX Text
BSH
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1" = 10'-0"
AutoCAD SHX Text
NOTE: ARCHITECTURAL, ELECTRICAL, AND MECHANICAL PLANS ARE ORIENTED DIFFERENTLY THAN SITE PLAN. PLEASE NOTE NORTH ARROW ON EACH PLAN SHEET FOR PROPER ORIENTATION.
AutoCAD SHX Text
0'
AutoCAD SHX Text
5'
AutoCAD SHX Text
10'
AutoCAD SHX Text
20'
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
CERTIFICATION:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ISSUES
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
18061
AutoCAD SHX Text
ARCHITECT OF RECORD
AutoCAD SHX Text
3-18-20 ISSUED FOR PERMITS
Page 3: R C101 - epcdevplanstorage.blob.core.windows.net€¦ · new 3'-0" man gate -see detail . precast generator pad furnished and installed by building manufacturer -see manufacturer

1 CHAIN-LINK FENCE DETAIL

4 TRUSS ROD AND BAND

LINE POST CORNER POST

2 EXTENSION ARM DETAILS

TOP/BRACE RAIL ATTACHMENT ROUND POST

3 FASTENING DETAILS

TENSION BAND

AND WIRE DETAIL ROUND POST END OR GATE POST DETAIL

5 TRUSS ROD AND BAND

C200

FENCE DETAILS

architects interiors.

CO

LO

RA

DO

SP

RIN

GS

, C

O 8

0930

18304 H

IGH

WA

Y 9

4

DESIGN GROUP

15925 HARGRAY DRIVE NOBLESVILLE, INDIANA 46062

P: 833-348-3934www.five9dg.com

THIS IS AN ORIGINAL DESIGN, CREATED BY FIVE NINE DESIGN GROUP THECONCEPTS, IDEAS, PLANS AND DETAILS ARE THE SOLE PROPERTY OFFIVE NINE DESIGN GROUP. NONE OF THE CONCEPTS, IDEAS, PLANS ORDETAILS SHALL BE COPIED, USED BY, OR DISCLOSED TO ANY PERSON,FIRM OR CORPORATION FOR ANY PURPOSE WITHOUT THE PRIORWRITTEN PERMISSION OF FIVE NINE DESIGN GROUP. WRITTENDIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALEDIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FORALL DIMENSIONS AND CONDITIONS ON THE JOB AND FIVE NINE DESIGNGROUP MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONSAND CONDITIONS SHOWN ON THESE DRAWINGS.

AutoCAD SHX Text
9 GA. TENSIONED CHAIN LINK FENCE FABRIC W/ MAX. 2" SQUARE MESH (TYP).
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
BRACE RAIL
AutoCAD SHX Text
BARBED-WIRE APRON ON EXTENSION ARMS
AutoCAD SHX Text
TRUSS ROD (3/8" MIN. DIA.)
AutoCAD SHX Text
CHAIN-LINK FABRIC (9 GAGE, 2" MESH), TYP.
AutoCAD SHX Text
BOTTOM OF FABRIC
AutoCAD SHX Text
LINE POST
AutoCAD SHX Text
TENSION WIRE SEE
AutoCAD SHX Text
CORNER, END, OR PULL POST
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
10'-0" MAX.
AutoCAD SHX Text
10'-0" MAX.
AutoCAD SHX Text
10'-0" MAX.
AutoCAD SHX Text
10'-0" MAX.
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
CONCRETE BASE
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
FRABIC WIDTH
AutoCAD SHX Text
HOG RINGS, TYP.
AutoCAD SHX Text
TIE WIRE OR CLIPS, TYP. - SEE DTL
AutoCAD SHX Text
TIE WIRES OR HOG RINGS, TYP.
AutoCAD SHX Text
PULL POST
AutoCAD SHX Text
CORNER, END, & PULL POSTS
AutoCAD SHX Text
TUBULAR - ROUND
AutoCAD SHX Text
TUBULAR - SQUARE
AutoCAD SHX Text
C-SECTION (ROLL-FORMED)
AutoCAD SHX Text
2.375" O.D.
AutoCAD SHX Text
2.00" SQ.
AutoCAD SHX Text
3.50" x 3.50"
AutoCAD SHX Text
FABRIC WIDTH 72" OR LESS
AutoCAD SHX Text
2.875" O.D.
AutoCAD SHX Text
2.50" SQ.
AutoCAD SHX Text
3.50" x 3.50"
AutoCAD SHX Text
FABRIC WIDTH 84" TO 96"
AutoCAD SHX Text
4.00" O.D.
AutoCAD SHX Text
3.00" SQ.
AutoCAD SHX Text
----------
AutoCAD SHX Text
FABRIC WIDTH 108" AND OVER
AutoCAD SHX Text
LINE POSTS
AutoCAD SHX Text
C-SECTION (ROLL-FORMED)
AutoCAD SHX Text
1.90" O.D.
AutoCAD SHX Text
2.25" x 1.70"
AutoCAD SHX Text
1.875" x 1.625"
AutoCAD SHX Text
2.375" O.D.
AutoCAD SHX Text
2.25" x 1.70"
AutoCAD SHX Text
2.25" x 1.70"
AutoCAD SHX Text
2.875" O.D.
AutoCAD SHX Text
2.25" x 1.70"
AutoCAD SHX Text
----------
AutoCAD SHX Text
TUBULAR - ROUND
AutoCAD SHX Text
H - SECTION
AutoCAD SHX Text
TOP, BOTTOM & BRACE RAILS
AutoCAD SHX Text
H-SECTION
AutoCAD SHX Text
1.66" O.D.
AutoCAD SHX Text
1.50" SQ.
AutoCAD SHX Text
1.625" x 1.50"
AutoCAD SHX Text
TUBULAR - ROUND
AutoCAD SHX Text
TUBULAR - SQUARE
AutoCAD SHX Text
C-SECTION (ROLL-FORMED)
AutoCAD SHX Text
1.625" x 1.25"
AutoCAD SHX Text
USE AND SECTION
AutoCAD SHX Text
MINIMUM OUTSIDE DIMENSIONS (NOMINAL)
AutoCAD SHX Text
STEEL POST SCHEDULE
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TENSION BAND - SEE DTL
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
BOTTOM TENSION WIRE OR RAIL SEE
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
GALV. " 12" DROP ROD
AutoCAD SHX Text
GALV. GATE FRAME
AutoCAD SHX Text
HEAVY DUTY GALV. LATCH ASSEMBLY
AutoCAD SHX Text
3 STRANDS OF DOUBLE STRAND GALV. 13.75 GA MIN. TENSIONED LINE WIRE W/ (4) POINT BARBS SPACED 5" O.C. MAX.
AutoCAD SHX Text
3/8" DIA. TRUSS ROD, TYP.
AutoCAD SHX Text
3/8" DIA. TRUSS ROD, TYP.
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
2" MIN. 2" MAX FOR SENSORED FENCES 5" MAX FOR NON-SENSORED FENCES
AutoCAD SHX Text
UNDISTURBED SOIL
AutoCAD SHX Text
3/16" X 3/4" ONE PIECE TENSION BAR - 2" SHORTER THAN FABRIC HEIGHT. PROVIDE WHERE FABRIC MEETS TERMINAL POSTS
AutoCAD SHX Text
3/4" ONE PIECE TENSION BAR TYP(2) SIDES EA. LEAF SEE
AutoCAD SHX Text
GALV. HEAVY DUTY GATE HINGES TYP. (2) EACH LEAF
AutoCAD SHX Text
1" 1.D. STEEL PIPE
AutoCAD SHX Text
6" DIA. CONCRETE
AutoCAD SHX Text
12" SAND OR GRAVEL FOR DRAINAGE
AutoCAD SHX Text
4" DIA. POST EITHER SIDE OF GATE, TYPICAL
AutoCAD SHX Text
BRACE RAIL
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C200
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
3/8" PLAIN PIN RIVETED FLUSH (TYP.)
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
LOCK PIN, (TYP.)
AutoCAD SHX Text
GALV. WIRE ARM
AutoCAD SHX Text
3/8" PLAIN PIN RIVETED FLUSH (TYP.)
AutoCAD SHX Text
LOCK PIN, (TYP.)
AutoCAD SHX Text
BARBED WIRE, (TYP.)
AutoCAD SHX Text
GALV. WIRE ARM
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C200
AutoCAD SHX Text
1 1/2" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1 1/2" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1 1/2" = 1'-0"
AutoCAD SHX Text
DOUBLE WRAP 13-GAGE STEEL TIE WIRES (2'-0" O.C. MAX.)
AutoCAD SHX Text
FABRIC
AutoCAD SHX Text
DOUBLE WRAP 13-GAGE STEEL TIE WIRES (15'-0" O.C. MAX. AND WITHIN 4" FROM TOP AND BOTTOM OF FABRIC)
AutoCAD SHX Text
FABRIC
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C200
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
TENSION BAND
AutoCAD SHX Text
TENSION BAR
AutoCAD SHX Text
CARRIAGE BOLT
AutoCAD SHX Text
3/16" X 3/4" ONE PIECE TENSION BAR TO ENGAGE EACH FABRIC LINK
AutoCAD SHX Text
FABRIC
AutoCAD SHX Text
TENSION BAND (15" O.C. MAX. AND WITHIN 4" FROM TOP AND BOTTOM OF FABRIC)
AutoCAD SHX Text
GALV. 7 GAUGE STEEL TENSION WIRE. MIN 75,000 PSI TENSILE STRENGTH. ATTACH WIRE TO EACH POST AND SECURE TO FABRIC W/ MW 12 1/2" GAUGE HOG TIES @ 24" O.C.
AutoCAD SHX Text
TRUSS ROD (3/8" MIN. DIA.)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C200
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
CONCRETE BASE
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
TRUSS ROD (3/8" MIN. DIA.)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
C200
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
61C200.DWG
AutoCAD SHX Text
REA
AutoCAD SHX Text
BSH
AutoCAD SHX Text
ARCHITECT OF RECORD:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
CAD FILE:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
CERTIFICATION:
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ISSUES
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
18061
AutoCAD SHX Text
3-18-20 ISSUED FOR PERMITS