42
Radiation Detection and Measurement Solutions “Doza” Scientific Production Company Scientific Production Company “Doza”, Ltd SPC “Doza”, Ltd Georgievskiy prospekt 6, Zelenograd, Moscow, 124498, Russia PO Box # 50, Moscow, 124460, Russia Tel.: +7 495 777-84-85 +7 495 984-20-50 Fax: +7 495 742-50-84 +7 499 734-02-56 E-mail: [email protected] [email protected] www.doza.ru

Upload: vuongnguyet

Post on 03-Jan-2017

254 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Radiation detection and measurement solutions PDF

Radiation Detection and Measurement Solutions

ldquoDozardquo Scientific Production Company

Scientific Production Company ldquoDozardquo LtdSPC ldquoDozardquo Ltd

Georgievskiy prospekt 6 Zelenograd Moscow 124498 Russia

PO Box 50 Moscow 124460 Russia

Tel +7 495 777-84-85 +7 495 984-20-50

Fax +7 495 742-50-84 +7 499 734-02-56

E-mail infodozaru maildozagmailcom

wwwdozaru

SPC ldquoDozardquo

2 3

SUCCEEDING TOGETHER IN RADIATION PROTECTION OF PEOPLE PROCESS AND ENVIRONMENT

Fast growing companyldquoDozardquo is one of the leading research and production companies specialized in design manufacture and supply of radiation monitoring solutions This is also one of the biggest developers of methodologies and software in Russian Federation and neighboring countries

Our company was founded in 1991 by a group of experts came from the Center of ionizing radiation ldquoVNIIFTRIrdquo based in Moscow region 20 years later our sales reached $30mln (2015) At least 5 of annual sales are re-invested in RampD

Our customers are essentially NPP fuel cycle companies National Nuclear authorities Emercom Ministry of Health Ministry of Defense Police Customs office National Transport organizations and Standard authorities research centers and laboratories Medical complexes Environmental organizations etc

Prior to supply our equipment to the end-users it passes thru a sophisticated test system and function analysis Most of our devices and equipment are supplied with the metering procedures which are adapted in compliance with the relevant normative documents After-sales service and maintenance are ensured by our service center We also organize trainings provide day-to-day customer service realize on-site servicing (assistance mounting installation commissioning maintenance) and make available a hot-line

SPC ldquoDozardquo

4 5

Quality management system ldquoDozardquo quality management system meets GOST ISO 9001-2011 requirements and is being a base of corporate management system Main company document that determines the principles of business doing operation and permanent improvement of the quality management system according to the principles and requirements of international stand-ards is the Quality Control Chart

Metrological service ldquoDozardquo has a quite developed metrological service based on the standards for dosimeters and radiom-eters calibration and verification pulse and static X-ray machines complying with ISO 4037 refer-ence X-ray dosimeter air flow volume calibration machine radioactive gases radiometer calibration standard gamma-sources Cs-137 Co-60 Co-57 Am-241 neutron Pu-Be sources alpha- and beta-sources and spectrometric sources Our metrological service is one of the best equipped laboratories in Russia It is accredited in performing primary and periodical verification and calibration More than 30000 verifi-cations per year are done in our lab

Our staff Over 200 people including 12 PhD and 85 engineers represent the most valuable capital of ldquoDozardquo

Seven employees of our company were awarded for their participation in elimination of the Chernobyl accident consequences Our experts participate in development and implementation of normative and methodological documents which make the basis of radiation safety in Russia

Among our specialists there are experts of bull Scientific and Technical Board of the State Atomic

Energy Corporation ldquoRosatomrdquo bull Technical committee 45 IEC ldquoNuclear instrumen-

tationrdquo bull Technical committee of 413 Rosstandart bull Coordination Council of the ldquoRosatomrdquo on the

development of the environmental radiation monitoring system (ERMS)

bull Working group of the ldquoRosatomrdquo on developing the ldquoIntegrated complex safety management system in the field of Nuclear Powerrdquo

bull Association of Medical Physicists of Russia (AMPR)

Manufacture and production capacitiesNew sophisticated machines and equipment ensure large production volume Own technology and highly skilled staff are key factors that allow us to guarantee a highest quality of suggested products

We use high technology laser metal sawing ma-chines powerful robotic processing equipment automated machine for board surface mount and some other Few years ago ldquoDozardquo built up new production building (1000 msup2) Now we have totally 2000 msup2 of production facilities and other 2000 msup2 are used for office and warehouse

Our product portfolioOur high scientific potential an extremely power-ful RampD and high adaptability to customer specs and markets needs allow us to supply reliable and cost-effective solutions which meet all requirements of domestic and international (IEC ISO) standards Our key product lines are portable dosimeters and radiometers spectrometers radiation monitoring system environmental surveillance stations critical accident alarm system medical equipment calibra-tion equipment Spare parts policy we commit to provide spare parts for our devices as soon as it is required by our customers

Business developmentWe are actually selling more than 200 different products in 20 countries We constantly increase our business volume in BRICS countries (Russia China India) and other newly developed regional powers We move fast forward in getting new accounts in Europe South America Asia and Middle East Our key target is to develop our business thru new partnership all over the world Any new partner is very welcome

ANRI magazine We have been releasing ldquoThe ANRI Journalrdquo (Radia-tion monitoring equipment and news) since 1994 We issue the most relevant research materials reports and articles dedicated to Health Physics radiation problematic methodology metrology and new equipment This Journal is referenced in Russian Federal Agency on Press and Mass Communication catalogue So ldquoThe ANRIrdquo is the exclusive periodical Russian journal focused on practical aspects of ra-diation monitoring It is also referenced in Chemical Abstracts

6

Radiation Monitoring

System

Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education

Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex

Radiation monitoring system SPC ldquoDozardquo

8 9

Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations

bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering

Obninskbull Russian Research Institute of Technical Physics

Sarov

REFERENCE

bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo

Moscowbull Kudankulam NPP Indiabull Tianwan NPP China

More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo

FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network

is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation

ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 2: Radiation detection and measurement solutions PDF

SPC ldquoDozardquo

2 3

SUCCEEDING TOGETHER IN RADIATION PROTECTION OF PEOPLE PROCESS AND ENVIRONMENT

Fast growing companyldquoDozardquo is one of the leading research and production companies specialized in design manufacture and supply of radiation monitoring solutions This is also one of the biggest developers of methodologies and software in Russian Federation and neighboring countries

Our company was founded in 1991 by a group of experts came from the Center of ionizing radiation ldquoVNIIFTRIrdquo based in Moscow region 20 years later our sales reached $30mln (2015) At least 5 of annual sales are re-invested in RampD

Our customers are essentially NPP fuel cycle companies National Nuclear authorities Emercom Ministry of Health Ministry of Defense Police Customs office National Transport organizations and Standard authorities research centers and laboratories Medical complexes Environmental organizations etc

Prior to supply our equipment to the end-users it passes thru a sophisticated test system and function analysis Most of our devices and equipment are supplied with the metering procedures which are adapted in compliance with the relevant normative documents After-sales service and maintenance are ensured by our service center We also organize trainings provide day-to-day customer service realize on-site servicing (assistance mounting installation commissioning maintenance) and make available a hot-line

SPC ldquoDozardquo

4 5

Quality management system ldquoDozardquo quality management system meets GOST ISO 9001-2011 requirements and is being a base of corporate management system Main company document that determines the principles of business doing operation and permanent improvement of the quality management system according to the principles and requirements of international stand-ards is the Quality Control Chart

Metrological service ldquoDozardquo has a quite developed metrological service based on the standards for dosimeters and radiom-eters calibration and verification pulse and static X-ray machines complying with ISO 4037 refer-ence X-ray dosimeter air flow volume calibration machine radioactive gases radiometer calibration standard gamma-sources Cs-137 Co-60 Co-57 Am-241 neutron Pu-Be sources alpha- and beta-sources and spectrometric sources Our metrological service is one of the best equipped laboratories in Russia It is accredited in performing primary and periodical verification and calibration More than 30000 verifi-cations per year are done in our lab

Our staff Over 200 people including 12 PhD and 85 engineers represent the most valuable capital of ldquoDozardquo

Seven employees of our company were awarded for their participation in elimination of the Chernobyl accident consequences Our experts participate in development and implementation of normative and methodological documents which make the basis of radiation safety in Russia

Among our specialists there are experts of bull Scientific and Technical Board of the State Atomic

Energy Corporation ldquoRosatomrdquo bull Technical committee 45 IEC ldquoNuclear instrumen-

tationrdquo bull Technical committee of 413 Rosstandart bull Coordination Council of the ldquoRosatomrdquo on the

development of the environmental radiation monitoring system (ERMS)

bull Working group of the ldquoRosatomrdquo on developing the ldquoIntegrated complex safety management system in the field of Nuclear Powerrdquo

bull Association of Medical Physicists of Russia (AMPR)

Manufacture and production capacitiesNew sophisticated machines and equipment ensure large production volume Own technology and highly skilled staff are key factors that allow us to guarantee a highest quality of suggested products

We use high technology laser metal sawing ma-chines powerful robotic processing equipment automated machine for board surface mount and some other Few years ago ldquoDozardquo built up new production building (1000 msup2) Now we have totally 2000 msup2 of production facilities and other 2000 msup2 are used for office and warehouse

Our product portfolioOur high scientific potential an extremely power-ful RampD and high adaptability to customer specs and markets needs allow us to supply reliable and cost-effective solutions which meet all requirements of domestic and international (IEC ISO) standards Our key product lines are portable dosimeters and radiometers spectrometers radiation monitoring system environmental surveillance stations critical accident alarm system medical equipment calibra-tion equipment Spare parts policy we commit to provide spare parts for our devices as soon as it is required by our customers

Business developmentWe are actually selling more than 200 different products in 20 countries We constantly increase our business volume in BRICS countries (Russia China India) and other newly developed regional powers We move fast forward in getting new accounts in Europe South America Asia and Middle East Our key target is to develop our business thru new partnership all over the world Any new partner is very welcome

ANRI magazine We have been releasing ldquoThe ANRI Journalrdquo (Radia-tion monitoring equipment and news) since 1994 We issue the most relevant research materials reports and articles dedicated to Health Physics radiation problematic methodology metrology and new equipment This Journal is referenced in Russian Federal Agency on Press and Mass Communication catalogue So ldquoThe ANRIrdquo is the exclusive periodical Russian journal focused on practical aspects of ra-diation monitoring It is also referenced in Chemical Abstracts

6

Radiation Monitoring

System

Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education

Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex

Radiation monitoring system SPC ldquoDozardquo

8 9

Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations

bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering

Obninskbull Russian Research Institute of Technical Physics

Sarov

REFERENCE

bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo

Moscowbull Kudankulam NPP Indiabull Tianwan NPP China

More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo

FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network

is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation

ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 3: Radiation detection and measurement solutions PDF

SPC ldquoDozardquo

4 5

Quality management system ldquoDozardquo quality management system meets GOST ISO 9001-2011 requirements and is being a base of corporate management system Main company document that determines the principles of business doing operation and permanent improvement of the quality management system according to the principles and requirements of international stand-ards is the Quality Control Chart

Metrological service ldquoDozardquo has a quite developed metrological service based on the standards for dosimeters and radiom-eters calibration and verification pulse and static X-ray machines complying with ISO 4037 refer-ence X-ray dosimeter air flow volume calibration machine radioactive gases radiometer calibration standard gamma-sources Cs-137 Co-60 Co-57 Am-241 neutron Pu-Be sources alpha- and beta-sources and spectrometric sources Our metrological service is one of the best equipped laboratories in Russia It is accredited in performing primary and periodical verification and calibration More than 30000 verifi-cations per year are done in our lab

Our staff Over 200 people including 12 PhD and 85 engineers represent the most valuable capital of ldquoDozardquo

Seven employees of our company were awarded for their participation in elimination of the Chernobyl accident consequences Our experts participate in development and implementation of normative and methodological documents which make the basis of radiation safety in Russia

Among our specialists there are experts of bull Scientific and Technical Board of the State Atomic

Energy Corporation ldquoRosatomrdquo bull Technical committee 45 IEC ldquoNuclear instrumen-

tationrdquo bull Technical committee of 413 Rosstandart bull Coordination Council of the ldquoRosatomrdquo on the

development of the environmental radiation monitoring system (ERMS)

bull Working group of the ldquoRosatomrdquo on developing the ldquoIntegrated complex safety management system in the field of Nuclear Powerrdquo

bull Association of Medical Physicists of Russia (AMPR)

Manufacture and production capacitiesNew sophisticated machines and equipment ensure large production volume Own technology and highly skilled staff are key factors that allow us to guarantee a highest quality of suggested products

We use high technology laser metal sawing ma-chines powerful robotic processing equipment automated machine for board surface mount and some other Few years ago ldquoDozardquo built up new production building (1000 msup2) Now we have totally 2000 msup2 of production facilities and other 2000 msup2 are used for office and warehouse

Our product portfolioOur high scientific potential an extremely power-ful RampD and high adaptability to customer specs and markets needs allow us to supply reliable and cost-effective solutions which meet all requirements of domestic and international (IEC ISO) standards Our key product lines are portable dosimeters and radiometers spectrometers radiation monitoring system environmental surveillance stations critical accident alarm system medical equipment calibra-tion equipment Spare parts policy we commit to provide spare parts for our devices as soon as it is required by our customers

Business developmentWe are actually selling more than 200 different products in 20 countries We constantly increase our business volume in BRICS countries (Russia China India) and other newly developed regional powers We move fast forward in getting new accounts in Europe South America Asia and Middle East Our key target is to develop our business thru new partnership all over the world Any new partner is very welcome

ANRI magazine We have been releasing ldquoThe ANRI Journalrdquo (Radia-tion monitoring equipment and news) since 1994 We issue the most relevant research materials reports and articles dedicated to Health Physics radiation problematic methodology metrology and new equipment This Journal is referenced in Russian Federal Agency on Press and Mass Communication catalogue So ldquoThe ANRIrdquo is the exclusive periodical Russian journal focused on practical aspects of ra-diation monitoring It is also referenced in Chemical Abstracts

6

Radiation Monitoring

System

Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education

Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex

Radiation monitoring system SPC ldquoDozardquo

8 9

Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations

bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering

Obninskbull Russian Research Institute of Technical Physics

Sarov

REFERENCE

bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo

Moscowbull Kudankulam NPP Indiabull Tianwan NPP China

More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo

FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network

is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation

ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 4: Radiation detection and measurement solutions PDF

6

Radiation Monitoring

System

Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education

Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex

Radiation monitoring system SPC ldquoDozardquo

8 9

Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations

bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering

Obninskbull Russian Research Institute of Technical Physics

Sarov

REFERENCE

bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo

Moscowbull Kudankulam NPP Indiabull Tianwan NPP China

More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo

FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network

is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation

ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 5: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

8 9

Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations

bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering

Obninskbull Russian Research Institute of Technical Physics

Sarov

REFERENCE

bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo

Moscowbull Kudankulam NPP Indiabull Tianwan NPP China

More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo

FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network

is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation

ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 6: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

10 11

SKGAV Stack monitor

UPPVM Air flow parameters monitor

RM Rack

UDG-1B Noble gas monitor

UDGB-01Noble gasesH-3C-14

monitor

UDA-1AB Particulate monitor

UDI-1BIodine monitor

UDGP-01 Steam generator leakage

monitor

RMSworkstation

Ethernet switch

Ethe

rnet

RS

-485

RMS workstationServer

Ethernet RS-485

UDGP-01 Liquidtechnological environment monitor

DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor

UDMN-100 Neutron area monitor

BDRG-52 High range gamma area monitor

BASBAS-1s External alarm

BOP-1M Data processing and

transmission unit

RADIATION MONITORING SYSTEM

Ethe

rnet

RS

-485

BI-2 Remote display amp alarm unit

ldquoImpulsrdquoExternal Display Unit

UDKG-100 Wel Liquid gamma monitor

Ethernet RS-485

UDG-03D Noble gas monitor

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 7: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

12 13

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

BOP-1M

Reference standards Nuclear IEC 60532

bull Continuous automatic monitoring of the ambient dose equivalent rate

bull Нigh temperature range (up to 120 degC)

BDMG-101 HIGH RANGE GAMMA AREA MONITOR

Physical characteristicsbull detector ndash ionization chambers

Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh

Energy rangebull 005 divide 30 MeV

temperature rangebull ionization chamber module MIC-1

minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME

minus 30 divide +60 degC

Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m

Mechanical characteristicsbull Protection index IP 65

Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg

BOP-1M

Reference standards Nuclear IEC 60846 IEC 60532

Versionsbull stainless steel 100 cm2 ionization chamber

module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module

(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module

(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module

(MIC-4) and electrometric module (ME)

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 8: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

14 15Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry

Physical characteristicsbull Detector ndash scintillator CsI NaI

Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull gamma 005 divide 15 MeV

Temperature range bull minus 10 divide +80 ordmС

UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR

Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit

CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg

bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

bull Continuous automatic monitoring of the ab-sorbed dose rate

bull Monitoring inside containmentbull Delivery assembled detector and communication

linebull Communication line include inter wall protective

tubebull Hermetic communication line filled dry nitrogen

Physical characteristicsbull detector - stainless steel ionization chamber

Measurement range bull 10-3 divide 105 Gyh

Energy range bull 006 divide 30 MeV

Temperature range bull detector

0 divide 207 ordmC continuous

250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC

Detector operating pressure bull 07 МPa

Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up

to 70 m

BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS

Ionization chamber

Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel

Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)

1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg

Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 9: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

16 17

BOP-1M DATA PROCESSING AND TRANSMISSION UNIT

bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52

bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of

detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of

preset thresholdsbull Data backup in the non-volatile memory

Physical characteristicsbull Quantity of joined detecting blocks and alarm

units ndash up to 20bull Temperature range minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable

Overall dimensions weightbull 298times220times114 mm 5 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

UDKG-100WEL LIQUID GAMMA MONITOR

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge

Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm

Measurement range bull 40 divide 8104 s-1cm-2

Energy range bull 01divide 30 MeV

Temperature rangebull minus 40 divide +50 degC

Electrical characteristics bull Interfaces RS-485

Mechanical characteristics bull Protection index

Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65

bull Paint stainless steel bull Overall dimensions weight

Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 10: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

18 19

UDG-1B NOBLE GAS MONITOR

Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of

preset thresholds bull Periodic calibration by means of standard beta-

source

Physical characteristicsbull Silicon detectors (2 pcs for measurement and for

background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1

395times468times950 mm 543 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Mobile version with pump unit BN-1

Stationary version

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

bull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

UDA-1AB PARTICULATE MONITOR

Stationary version

Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background

compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of

preset thresholds bull Control of electromagnetic valves when operating

with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-

and alpha-sources

Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-

ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1

389times468times950 mm 384 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Mobile version with pump unit BN-1

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 11: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

20 21

Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)bull Cartridge activated charcoal

Measurement range bull 37 divide 37106 Bqm3

Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1

448times468times950 mm 578 kg

Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1

Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-

clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholdsbull Periodic calibration by means of standard source

UDI-1B IODINE MONITOR

Physical characteristicsbull Silicon detector 2 pcs (for measurement and for

background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Measurement range bull 104 divide 11010 Bqm3

Energy rangebull 006 divide 30 MeV

Electrical characteristicsbull Power supply 120 Vbull Interface RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 474х246х243 mm 295 kg

UDG-03D NOBLE GAS MONITOR

Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-

source

Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 12: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

22 23

Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check

source implanted into the detectorbull Audible and visual alarm signals of the excess of

preset thresholds

Physical characteristics

UDGP-01 STEAM GENERATOR LEAKAGE MONITOR

bull detector ndash scintillator CsI Oslash 40х100 mm

Measurement range bull High energy gamma-activity (N-16)

15bull103 divide 20bull108 Bqm3

bull General gamma-activity 10bull104 divide 20bull108 Bqm3

Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy

5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС

BOP-1SP

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp

280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo

type

Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Ionization chambe 10 liters

UDGB-01T1

Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС

Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter

Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3

bull UDGB-01T2 109 divide 501014 Bqm3

Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3

bull UDGB-01T2 50109 divide 501014 Bqm3

Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)

Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable

Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of

preset thresholds bull Monitoring of the noble gase activity in gaseous

effluents and ventilation air for accident and post-accident conditions

Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm

6 kgbull UDGB - 01T2 381times343times716 mm 27 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Versionsbull UDGB-01T - with built-in ionization chamber

100 litersbull UDGB-01T2 - with built-in ionization chamber

01 literbull UDGB-01T1 - with remote ionization chamber

100 liters

UDGB-01NOBLE GASESH-3C-14 MONITOR

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 13: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

24 25

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg

ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT

Display of data received from monitors of RMS

External display unit ldquoImpuls-910-Rrdquo

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking

into account temperature and humidity of the air

UPPVM AIR FLOW PARAMETERS MONITOR

Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet

Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable

Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe

IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s

280x233x111 mm 8 kg

Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

BOP-1S

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 14: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

26 27

BASBAS-1S EXTERNAL ALARM

Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red

Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m

Power supply bull 220 V 50 Hz

Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Physical characteristicsLength of communication cablebull up to 1200 m

Displayed page size bull 4 lines of 20 characters

Volume of loaded information bull 10 pages

Change of pagesbull programmed or by pressing a button

Operating temperature rangebull minus 40 divide +50 ordmC

Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm

40 kg

BI-2 REMOTE DISPLAY amp ALARM UNIT

bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset

thresholds of the RMS equipment bull Individual threshold setting for each measure-

ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green

Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 15: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

2928

Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type

Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack

Air flow parameters monitor rack

Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

Sampling and sample separation rack

Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-

radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks

bull Monitoring of the flow rate temperature and humidity of the gas flow

bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter

bull Reversion of gas after analysis to the ventilation system

Physical characteristics

Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-

ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)

10 m50 days

Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3

Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV

Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for

gamma-background compensation)

Measurement range bull 104 divide 6109 Bqm3

Energy range bull 008 divide 30 MeV

Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-

ment and for background compensation)

SKGAV STACK MONITOR

Particulate noble gas and iodine monitors rack

Measurement range bull 37 divide 37105 Bqm3

Energy range bull 015 divide 30 MeV

Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 16: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

30 31

CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS

monitorsbull Monitors measurement results archive receive

and View bull Communication through RS-232

RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors

Single monitor console includes vandal-proof key-board amp UPS

Reference standard IEC 61559-1 IEC 61559-2

RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 17: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

32 33

Delivery setComposition and modification depend on the tasks to be solved using the RM Rack

The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B

UDGB-01Tbull DBG-S11D Wide range gamma area monitor

BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor

bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball

valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-

ment and transfer of data to the upper level via the unified communication channel)

RM RACK RADIATION MONITORING RACK

The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials

FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities

The stand providesbull Primary processing storage and transmission of

measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)

bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface

bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded

bull Display of received data on the LCD

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 18: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

34 35

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with pow-er supply

Visual alarm units BSS-01D

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

RS-485

RS-485

RS-4

85

Audible alarm units BZS-01D

Illuminated warning signs SIT-01D

Detection units BR-04D

Network communication

moduleDBG-S11D wide range gamma area monitor

Panels for muting audible alarm

Control unit with power supply

Visual alarm units BSS-01D

Ethernet

Central display panel Service workstation

RS-485

RS-485

RS-4

85

BZS-01D audible alarm units

SIT-01D illuminated warning signs

BR-04D detection units

Network communication

moduleDBG-S11D wide range gamma area monitor

PBZ panels for muting audible alarm

Control unit with power supply

BSS-01D visual alarm units

Reference standards IEC 60860 ANSIANS-83 ISO 7753

Purposebull Detection and recording of criticality accident

(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals

bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service

Functions of the systembull Detection and recording of CA events by con-

tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm

bull Activation of audible visual alarmbull In the event of CA turning on warning signals

ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area

Featuresbull Data can be transferred to external data commu-

nication channel using RS-485 interface (DiBus data exchange protocol)

bull Automatic self-testing of detection units BR-04D with display of information about the type of fault

bull Possibility for connecting additional a detection and alarm units

bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks

bull Radiation hardness up to 100 Gy

SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM

Features of softwarebull Collection of information via RS-485 network

displaying it on the PC monitor transmission to remote users archiving and storage

bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises

bull Access to archived data with possibility to gener-ate reports for periods determined by operator

bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps

bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems

Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module

Additional lower layer devicesbull DBG-S11D wide range gamma area monitor

Upper layer bull CDP central display panelbull Service workstation

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 19: Radiation detection and measurement solutions PDF

Radiation monitoring system SPC ldquoDozardquo

36 37

ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER

Physical characteristicsbull Measurement range of air flow rate

250 divide 1200 m3hbull Continuous operation time not less than 24 h

Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15

Electrical characteristicsPower supply bull 220380 V 50 Hz

Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)

Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC

Relative humidity limit at 35 ordmC bull 95

Atmospheric pressure range bull 840 divide 1067 kPa

Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring

System (ERMS)

Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block

The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part

of Environmental Radiation Monitoring System (ERMS)

Purposebull Environmental Radiation Monitoring System

(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities

Referencesbull Since the year 2000 the system is successfully

operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)

bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)

bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions

Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D

Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server

By requestbull Emergency Response and Crisis Management

Centers for enterprisesbull Regional Emergency Response and Crisis Manage-

ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash

sensorrdquo

ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM

Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network

Data transmission bull GSMGPRS

Power supply bull 220 V 50 Hz

Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours

Operation temperature bull Minus 40 divide +50 ordmC

Operation humidity bull Up to 98

Protection bull IP65

Reference standards Nuclear IEC 61017-11991 IEC 61017-21994

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 20: Radiation detection and measurement solutions PDF

38

Radiation Monitoring Equipment

bull Localization of radioactive contaminationsbull Database with dose rate contaminations

spectra measurement date amp time coordi-nates

bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer

Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters

Measurement rangebull 01 ndash 107 μSvh

Energy range bull 005 ndash 3 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristics bull Power supply 220 V 50 Hz

ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 21: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

40 41

BPI-1D LOCAL DISPLAY UNIT

Display of monitored parameters values received from external measuring devices

Purposebull Processing and display of values of monitored

parameters on information panel bull Comparison of values of monitored parameters

with thresholdsbull Transfer of monitored parametersrsquo values to

networkbull Generation of alarm in case of exceeding of preset

thresholds including external alarm devices

FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to

PC via USB

Automatic self-testing

The panel displays the following informationbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC

Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15

Display diagonal bull 152 cm (6)

Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V

Mechanical characteristicsbull Protection index IP54bull Paint decontaminable

Overall dimensions weightbull 296x248x118 mm 5 kg

AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc

Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements

Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation

DBG-S11D wide range gamma area monitor

UDMN-100 neutron area monitor

Ethernet RS-485

UDKS-100 gamma and X-ray area monitor

BPI-1D Local display unit

BAS-2 ldquoMicrordquo external visual alarm

BZS-2 ldquoMicrordquo external audible alarm

ldquoImpulsrdquo external display unit

Service workstation

Illuminated warning signs

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 22: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

4342

Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate

Physical characteristicsbull Detector tissue-equivalent plastic scintillator

Oslash 45times20 mm

Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV

Mechanical characteristicsbull Protection index IP65bull Paint decontaminable

Overall dimensions weightbull Oslash72times265 mm 15 kg

UDKS-100 GAMMA AND X-RAY AREA MONITOR

UDMN-100 NEUTRON AREA MONITOR

Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6

Measurement range bull 01 μSvh divide 01 Svh

Energy range bull 0025 eV divide 100 MeV

Temperature range bull minus 45 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485

Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable

Overall dimensions weight bull 428times258times347 mm 115 kg

Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm

MEASURING UNITS

DBG-S11D WIDE RANGE GAMMA AREA MONITOR

Continuous automatic monitoring of the gamma- ambient dose equivalent rate

Physical characteristicsbull Detector ndash GM counters

Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh

Energy rangebull 005 divide 30 MeV

Temperature range bull minus 40 divide +50 ordmC

Electrical characteristicsbull Interfaces RS-485 USB

Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable

Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg

Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02

Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 23: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

4544

Physical characteristicsLength of communication cablebull up to 1200 m

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight bull 330times110times20 mm 05 kg

Physical characteristicsLength of communication cablebull up to 1200 m

Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm

Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65

Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg

ILLUMINATED WARNING SIGNS

ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT

ALARM UNITS

Generation visual signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM

Generation audible signals of the excess of preset thresholds

Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m

Electrical characteristicsbull Power supply +12 V

Mechanical characteristicsbull Protection index IP 23

Overall dimensions weight 160times84times41 mm 02 kg

BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 24: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

4746

Measurement of alpha radiation flux density

Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2

Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2

Measurement of beta radiation flux density

Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2

Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2

Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2

OPTIONAL PROBESMeasurement of gamma radiation flux density

Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2

Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2

Measurement of the ambient dose equivalent rate

Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh

Measurement of neutron radiation ambient dose equivalent rate

Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh

Individual threshold setting for each measurement channel

Continuous area and process monitoring

Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)

Audible and visual alarms on exceeding preset thresholds or status of connected devices

Individual threshold setting for each measurement channel

Switching on the external alarm or executive devices when any threshold is exceeded

The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2

s-1∙cm-2 μSvhbull Diagnostic information about the status of con-

nected devicesbull Current date and timebull Position of measured values with respect to the

thresholds in the form of scales with green yellow and red zones

bull Time history (trend) for each measured value

Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)

Operating temperature range bull minus 20 divide +50 ordmC

Electrical characteristics bull Power supply 220 V bull Interfaces USB

Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm

40 kg

UIM-3D AREA MONITOR COUNT RATE METER

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 25: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

48 49

Physical characteristicsDetectors bull Silicon Li-6

Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Gamma energy range bull 005 divide 60 MeV

Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv

Neutron energy range bull 0025 eV divide 20 MeV

Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D

Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet

UZS-01DReference standards Nuclear IEC 61526

DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER

Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operationbull Both albedo thermal neutrons and intermediate

fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other

neutron sources as well as near nuclear reactors without neutron spectrum estimation

Reference standards Nuclear IEC 61526

Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric

system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-

etry operation

DKG-05D PERSONAL GAMMA DOSIMETER

Physical characteristicsDetectors bull Silicon

Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv

Energy range bull 005 divide 30 MeV

Electrical characteristicsbull Power supply rechargeable NiMH battery 1

alcaline battery (type AAA)

Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours

Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g

Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant

Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED

Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D

Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet

KZU-28

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 26: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

50 51

DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER

Physical characteristicsDetectors bull GM counters

Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv

Energy range bull 005 divide 3 MeV

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg

Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant

Reference standards Nuclear IEC 60846

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition

estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset

dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-

tion casebull 100 measurement results memory with date and

time of measurementbull Indication of total dose accumulated during

exploitation time bull Indication of measurement result statistical

uncertainty

Dosimeters DVG-03D

DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS

Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and

X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-

tenance

Physical characteristicsDetector bull Ionization chamber

Measurement range bull 001 mSv divide 25 mSv

Energy range bull 0015 divide 25 MeV

Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС

Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20

Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg

Reference standards Nuclear IEC 62387-1

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 27: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

52 53

Continuous measurement with updating measure-ment result

Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-

urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the

measurementbull Continuous measurement with accuracy increas-

ing with time bull Automatic restart triggered by change of gamma

dose-ratebull Compensation of gamma count rate while meas-

uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold

Physical characteristicsDetectors bull GM counter

Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)

10 divide 105 cm-2 min-1

Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

MKS-15D ldquoSnegirrdquo backside

MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER

Reference standards Nuclear IEC 60846 IEC 60325

Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours

Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg

Physical characteristicsDetectors bull GM counter

Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv

Energy range bull 005 divide 3 MeV

Temperature range bull Minus 20 divide +50 ordmC

Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours

Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg

Reference standards Nuclear IEC 60846

DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER

Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose

and dose ratebull Audible signals (clicks) for radiation condition

estimationbull Continuous measurement with updating meas-

urement resultbull Measurement result can be obtained with any

desired statistical uncertainty (error)bull Automatic restart when radiation level sharply

changesbull Indication of statistical uncertainty (error) during

measurement process

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 28: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

54 55

Measurement ofbull Gamma and X-ray personal dose equivalent

Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating

Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)

Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv

Energy range bull 0015 divide 30 MeV

Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv

Energy range bull 0025 eV divide 10 MeV

Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv

Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV

Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm

16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g

Reference standards Nuclear IEC 61066

DTL-2 DTU-2

MKD (A-type) DVNG-M

DOZA-TLD MULTIPURPOSE TLD SYSTEM

Physical characteristicsDetectorbull GM counter

Measurement range bull 01 μSvh divide 20 mSvh

Energy range bull 005 divide 30 MeV

Threshold setting range bull 03 μSvh divide 20 mSvh

Step change of the thresholdbull In the range 03 divide 10 μSvh with the step

001 μSvhbull In the range 10 divide 100 μSvh with the step

01 μSvhbull In the range 100 divide 2000 μSvh with the step

10 μSvh

Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output

Mechanical characteristicsProtection index bull IP 40

Overall dimensions weight bull 226times120times75 mm 07 kg

Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit

Reference standards Nuclear IEC 60846 IEC 60532

Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset

thresholdsbull Switching on the external signaling or executive

devices

SRPS-05D GAMMA MONITOR

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 29: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

56 57

BDZA-96

BDZA-96B

BDZA-96M

BDZA-96S

BDZA-96T

EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2

Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2

Overall dimensions weightbull Oslash 130times240 mm 11 kg

ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2

Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2

Overall dimensions weightbull Oslash 230times290 mm 40 kg

ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2

Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2

Overall dimensions weightbull Oslash 65times240 mm 09 kg

ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2

Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2

Overall dimensions weightbull Oslash 90times240 mm 10 kg

ALPHA BDZA-96TDetector bull Silicon 5 сm2

Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2

Overall dimensions weightbull Oslash 50times60 mm 015 kg

Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and

liquid media measurement

Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery

Interfaces bull RS-232bull USB (via adapter)

bull Detector type automatic determination and corre-sponding measurement modes selection

bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations

bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes

Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363

Case

UIK-06 control unit165times78times48 mm 03 kg

DKS-96UNIVERSAL RADIATION SURVEY METER

UIK-05 control unit202times86times90 mm 10 kg

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 30: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

58 59

GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm

Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy rangebull 0015 divide 10 MeV

Overall dimensions weightbull Oslash 60times250 mm 085 kg

GAMMA AND BETA BDKS-96SDetector bull Double GM counters

Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2

Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV

Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m

GAMMA BDMG-96Detector bull GM counters

Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 005 divide 3 MeV

Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)

EXTERNAL PROBES GAMMA

BDKS-96B

BDMG-96

BDKS-96S

BETA BDZB-96Detector Scintillator 28 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2

Energy rangebull 03 divide 30 MeV

Overall dimensions weightbull Oslash 90times230 mm 09 kg

BETA BDZB-99Detector bull GM counter 30 сm2

Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m

BETA BDZB-96BDetector bull GM counter 80 сm2

Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull 150times200times110 mm 15 kg

BETA BDZB-96Sbull Detector GM counter 15 сm2

Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2

Energy rangebull 012 divide 30 MeV

Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m

BDZB-96

BDZB-99

BDZB-96B

BDZB-96S

EXTERNAL PROBES BETA

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 31: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

60 61

EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2

bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m

NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)

Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 10 MeV

Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg

NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator

Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv

Energy range bull 0025 eV divide 14 MeV

Overall dimensions weightbull 295times142times100 mm 225 kg

BDKG-96M

BDMN-96

BDKN-96

GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm

Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m

GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm

Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)

Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m

GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm

Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2

bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)

Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m

EXTERNAL PROBES GAMMA

BDVG-96

BDPG-96M

BDPG-96

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 32: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

62 63

Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation

and contamination of detector unitsbull Individual threshold setting for each measure-

ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and

ldquoCLEANrdquo bull Indication of contaminated body parts on the

panel with image of the bodybull Optional remote alpha-detector

Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)

Measurement range bull Beta 5 divide 15000 min-1cm-2

bull Alpha 01 divide 10000 min-1cm-2

Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV

Operation temperature range bull +5 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull RS-485

Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)

Reference standards Nuclear IEC 61098

RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR

bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand-foot positioning for start of

measurementbull Automatic compensation of gamma background

and contamination of detectorbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Reference standards Nuclear IEC 61098

RZB-05D HAND-FOOT-CLOTHING MONITOR

Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)

Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15

N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204

bull Gamma Tc-99m I-123

Efficiencybull Alpha

Pu-239 40 U-234 25U-238 15

bull Beta Sr-90 +Y-90 40

Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2

bull Gamma 5103 divide 5106 min-1cm-2

Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV

Operation temperature range bull Minus 10 divide +50 ordmС

Electrical characteristicsbull Power supply 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg

Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 33: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

64 65

bull Simultaneous measurement of alphabeta activi-ties in the sample

bull Active shielding anti-coincidence background subtraction using GM counters

bull Lead shielding 30 mm

UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER

Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2

Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq

Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV

Electrical characteristicsPower supply bull 220 V 50 Hz

Interfaces bull RS-232bull USB

Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg

Versionsbull Detector area 500 mm2

bull Detector area 1000 mm2

UMF-2000 Detector area 1000 mm2

UMF-2000 Detector area 500 mm2

SpectraDec software for alpha-spectrometric measurements

RZA-05DALPHA HAND-MONITOR

bull No gas supply needed bull Numeric and color (red green) indication of

control resultsbull LED sensor of hand- positioning for start of

measurementbull Audible alarm signals of the excess of preset

thresholdsbull Measurement value indication min-1cm-2 or

Bqсm2

Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)

Efficiencybull Pu-239 20 bull U-234 14bull U-238 8

Measurement range bull 05 divide 105 min-1cm-2

Energy range bull 41 divide 90 MeV

Operation temperature range bull minus 10 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg

Reference standards Nuclear IEC 61098

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 34: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

66 67

bull Measurement of strontium-90 in the foodstuffs agricultural products etc

bull Measurement of gross beta activity in samplebull Self tests using built-in LED

ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER

Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm

Sample bull Plate Oslash70 mmbull Weight up to 15 g

Energy range bull 02 divide 30 MeV

Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 50 kg

Complete setBasic complete setbull Detector unit with plastic scintillator integrated

power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-

nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo

Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Beta

Reference standards IEC 61562

DRK DOSE AREA PRODUCT METER

DRK-1bull Diagnostic reference level (DRL) of patients

determinationbull Suitable for all basic types of x-ray machines

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement range bull 1 divide 104 cGycm2

Electrical characteristicsPower supply bull 220 V 50 Hz

DRK-1M-CTbull Measuring of dose length product

Physical characteristicsDetector bull Pencil Ionization Chamber

Measurement rangebull 05 divide 109 microGym

DRK-1Mbull Measuring of air kerma on sectional area of the

X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma

Physical characteristicsDetector bull Plane-parallel ionization chamber

Measurement rangebull 01 divide 109 microGym2

bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 35: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

68 69

ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-

mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in

foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED

Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm

Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg

Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg

Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz

Interface bull USB RS-232

Weight bull No more than 60 kg

Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys

of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64

spectrabull Additional power adapterbull Notebook and printer

Progress-Gamma

Reference standards IEC 61563

bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects

bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED

ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER

Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm

Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)

etc

Energy range bull 02 divide 30 MeV

Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq

Electrical characteristics Interface bull USB

Mechanical characteristicsWeight bull No more 120 kg

Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector

with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +

K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity

of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo

Optional equipment and servicebull Kit for radon measurements including calibration

of ldquoIC-63rdquo geometry for counting the charcoal samples

bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the

main library of radionuclides

Progress-Gamma

Reference standards IEC 61563

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 36: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

70 71

Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and

resultsbull Uncertainty calculations based on measurement

databull Self tests using built-in LED

ldquoPROGRESSrdquo WHOLE BODY COUNTER

Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm

Energy rangebull 02 divide 28 MeV

Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq

Mechanical characteristicsWeight bull No more than 120 kg

Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of

gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo

bull laquoProgressraquo software

Optional equipment and servicebull Program of internal radiation committed internal

radiation effective dose calculation by the stand-ard model

bull Background phantombull Personal computer and printer

Collimator with rotator and holder

Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)

Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight

200300 mg bull Preparation technique - application of powders

(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit

Energy rangebull 15 divide 8 MeV

Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg

Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg

Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)

Set of accessoriesbull Procedure manual for measurements of radi-

oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo

bull ldquoProgressrdquo software

ldquoProgress-ARrdquo

bull Measurement of gross activity of alpha emitting radionuclides in thin samples

bull Measurement of gross activity of alpha emitting radionuclides in thick samples

bull Measurement of activity deposited on aerosol filters

ldquoPROGRESS-ARrdquoALPHA RADIOMETER

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 37: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

72 73

bull Measurement of gross alpha activity of alpha-emitting radionuclides

bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements

Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2

bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector

Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum

detectable activity) 01 Bqbull Background count rate no more than 100 counts

in 24 hours

Electrical characteristics Power supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Detector unit with vacuum measuring chamber

and vacuum control systembull Low noise vacuum pump (type 2FY-05B or

equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube

MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER

bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition

bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)

bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)

bull Activity measurement of extended objects in situ without opening the equipment

bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)

MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM

Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and

multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar

bull Dose rate probe BDMG-200

Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV

Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at

13325 MeV (Co-60) 10 divide 150

Electrical characteristicsPower supplybull 220 V 50 Hz

Interfacebull USB

Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with

HPGe detector and multi-positioning cryostat with 7 litre Dewar

bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in

batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-

ing of the spectrometric detectorbull Calibration device with reference sources

(Am-241 Co-60 Ba-133 Eu-152) for energy calibration

bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 38: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

74 75

PVP-06PORTABLE AIR SAMPLER

Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges

Purposebull To monitor the concentration of radioactive aero-

sols in the air sites

Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes

Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20

Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)

Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery

Minimal working time on internal battery to recharge bull 8 hours

Power consumption (at a flow rate of 100 lmin) bull 40 VA

Environment characteristicsOperating temperature bull minus 10 divide +40 deg C

Maximum humidity bull 90

Pressure bull 860 to 1060 hPA

Noise generated by the pump bull lt 55 dBA at 1 m

Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg

Case material bull Plastic

Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate

Optional equimpient bull Kit for sampling sorption columns of activated

carbon Ř head of sorption columns with protective

covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs

bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs

Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20

UCRV-2AIRFLOW MONITOR

bull Monitor of the air flow through filter of centralized multichannel sampling system

bull Radiation monitoring system (RMS) integration for internal exposures determination

bull Volume and flow rate measurements of the air that have passed through a analytical filter

bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of

the RMS

Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3

Operation temperature range bull minus 20 divide +50 ordmС

Electrical characteristicsPower supply bull 220 V 50 Hz

Interface bull RS-485

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 39: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

76 77

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using

tumbler

UPG-P DESKTOP GAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)

Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137

Overall dimensions bull 1250times400times300 mm

Irradiator weight bull Not more than 37 kg

Calibration bench weight bull Not more than 15 kg

Reference standards IEC 60846 IEC 61526

Physical characteristicsDetectorbull Silicon

Measurement range EEC measurement bull Measurement range of radon EEC

10 divide 10bull106 Bqbullm-3

bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3

bull Air flow through the filter 100plusmn05 lmin

Concentration measurementbull Measurement range of radon-222 concentration

in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)

1bull10-3 divide 1bull102 cpsbull Air sampler flow rate

10plusmn02 lminbull Measurement range of radon-222 concentration

in water samples 6 divide 800 Bqbullkg-1

bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2

bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3

bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3

Operation temperature range bull 1 divide 35 ordmC

Electrical characteristicsPower supply bull 80 VA

Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg

ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration

and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-

al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface

at land plots allocated for construction of houses public buildings and industrial facilities

bull Measurements of radon concentration in soil air

Reference standards IEC 61577

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 40: Radiation detection and measurement solutions PDF

SPC ldquoDozardquoRadiation monitoring equipment

78 79

UKPN-2M-D NEUTRON BEAM IRRADIATOR

Reference standards IEC 61005 61322

Calibration of neutron dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of

sources bull Red light signal of source working position

Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh

Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1

Type of a source in use bull Pu-Be

Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)

Overall dimensions weight no morebull 3000x750x2000 mm 300 kg

Required room dimensionsbull not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

Calibration of gamma dose and dose rate meters

Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position

return to storage position using special rodbull Transfer container for temporary storage of

sources bull Red light signal of source working position

UPGD-2M-DGAMMA BEAM IRRADIATOR

Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)

Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137

Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m

Electrical characteristicsPower supply bull 220 V 50 Hz

UPGD-2M-D

Reference standards IEC 60846 IEC 61526 IEC 61066

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 41: Radiation detection and measurement solutions PDF

SPC ldquoDozardquo

80 81

Contents

MEASURING UNITS

DBG-S11D wide range gamma area monitor 40

UDKS-100 gamma and X-ray area monitor 41

UDMN-100 neutron area monitor 41

ALARM UNITS

BAS-2 ldquoMICROrdquo external visual alarm 42

BZS-2 ldquoMicrordquo external audible alarm 42

Illuminated warning signs 43

ldquoImpulsrdquo external display unit 43

UIM-3D area monitor count rate meter 44

DKG-05D personal gamma dosimeter 46

DVS-02D gamma-neutron personal electronic dosimeter 47

DVGI-8D new pen-type personal ionization chamber dosimeters 48

DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49

DKG-07D ldquoDROZDrdquo gamma-dosimeter 50

MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51

SRPS-05D gamma monitor 52

DOZA-TLD multipurpose TLD system 53

DKS-96 universal radiation survey meter 54

EXTERNAL PROBES ALPHA

Alpha BDZA-96 55

Alpha BDZA-96B 55

Alpha BDZA-96M 55

Alpha BDZA-96S 55

Alpha BDZA-96T 55

EXTERNAL PROBES BETA

Beta BDZB-96 56

Beta BDZB-99 56

Beta BDZB-96B 56

Beta BDZB-96S 56

EXTERNAL PROBES GAMMA

Gamma BDKS-96B 57

Gamma and beta BDKS-96S 57

Gamma BDMG-96 57

EXTERNAL PROBES GAMMA

Gamma-search BDVG-96 58

Gamma-search BDPG-96 58

ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6

BDMG-101 high range gamma area monitor 10

DBG-S11D wide range gamma area monitor 11

BDRG-52 high range gamma area monitor for accident and post-accident conditions 12

UDGP-01 Liquid technological environments monitor 13

UDMN-100 neutron area monitor 14

UDKG-100 Wel Liquid gamma monitor 14

BOP-1M data processing and transmission unit 15

UDA-1AB particulate monitor 16

UDG-1B noble gas monitor 17

UDG-03D noble gas monitor 18

UDI-1B iodine monitor 19

UDGB-01 noble gasesH-3C-14 monitor 20

UDGP-01 steam generator leakage monitor 21

UPPVM air flow parameters monitor 22

ldquoIMPULSrdquo external display unit 23

BI-2 remote display amp alarm unit 24

BASBAS-1s external alarm 25

SKGAV stack monitor 26

RMS software 28

RMS workstation ndash operator console 29

Configurator software 29

RM RACK radiation monitoring rack 30

SRKS-01D criticality accident alarm system 32

ldquoATLANT-Mrdquo environmental radiation monitoring system 34

ldquoBREEZErdquo high-volume air sampler 35

ldquoGAMMA-SENSORrdquo gamma-survey system 36

Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38

BPI-1D local display unit 39

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77

Page 42: Radiation detection and measurement solutions PDF

SPC ldquoDozardquo

82 83

Contents

Gamma-search BDPG-96M 58

Gamma BDKG-96 stainless steel casing for geologic applications well logging 59

EXTERNAL PROBES NEUTRON

Neutron BDMN-96 59

Neutron-search BDKN-96 59

RZB-05D Hand-foot-clothing monitor 60

RZBA-04-04M whole body contamination monitor 61

RZA-05D alpha hand-monitor 62

UMF-2000 low level alpha- beta- counter 63

DRK dose area product meter 64

ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65

ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66

ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67

ldquoPROGRESS-ARrdquo alpha radiometer 68

ldquoPROGRESSrdquo whole body counter 69

MKG-01D ldquoSADOVNIKrdquo spectrometry system 70

MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71

UCRV-2 airflow monitor 72

PVP-06 portable air sampler 73

ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74

UPG-P desktop gamma beam irradiator 75

UPGD-2M-D gamma beam irradiator 76

UKPN-2M-D neutron beam irradiator 77