RLAT Report 08-134 090626 R1.2 An ISO 9001:2000 Certified Company 1 Radiation Assured Devices 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad Precision Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) RAD Job Number: 08-134 Part Type Tested: Linear Technology RH1499MW Quad Precision Op Amp Commercial Part Number: RH1499MW Traceability Information: : Lot Date Code: 0731A, FAB W10737593.1, Wafer 19, LOT 447411.1 (Obtained from Linear Technology PO 49797L). See photograph of unit under test in Appendix A. Quantity of Units: : 11 units total, 5 units for biased irradiation, 5 units for unbiased irradiation and 1 control unit. Serial numbers 878, 879, 882, 883, and 885 were biased during irradiation, serial numbers 886, 887, 891, 892, and 895 were unbiased during irradiation and serial number 896 was used as the control. See Appendix B for the radiation bias connection table. External Traveler: None required Pre-Irradiation Burn-In: Burn-In performed by Linear Devices prior to receipt by RAD. TID Dose Rate and Test Increments: 50-300rad(Si)/s with readings at pre-irradiation, 10, 20, 30, and 50krad(Si) TID Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a 168-hour 100°C anneal. Both anneals shall be performed in the same electrical bias condition as the irradiations. Electrical measurements shall be made following each anneal increment. TID Test Standard: MIL-STD-883G, Method 1019.7, Condition A TID Electrical Test Conditions: Pre-irradiation, and within one hour following each radiation exposure. Hardware: LTS2020 Tester, 2101 Family Board, 0600 Fixture, and RH1499 BGSS-061114 DUT Card. Facility and Radiation Source: Radiation Assured Devices Longmire Laboratories, Colorado Springs, CO using the JLSA 81-24 high dose rate Co60 source. Dosimetry performed by CaF TLDs traceable to NIST. RAD’s dosimetry has been audited by DSCC and RAD has been awarded Laboratory Suitability for MIL-STD-750 TM 1019.5. Irradiation and Test Temperature: All irradiations and electrical tests performed at room temperature controlled to 24°C ± 6°C per MIL STD 883. RLAT Test Result: PASSED to 30krad(Si) but FAILED at 50krad(Si) due to degradation of the output voltage swing and short circuit current for the single- sided 3V supply condition and the power supply rejection ratio at the single- sided 2.2V to 12V supply range

Upload: others

Post on 25-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

1

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad Precision Op Amp for Linear Technology

Customer: Linear Technology (PO 49797L) RAD Job Number: 08-134 Part Type Tested: Linear Technology RH1499MW Quad Precision Op Amp Commercial Part Number: RH1499MW Traceability Information: : Lot Date Code: 0731A, FAB W10737593.1, Wafer 19, LOT 447411.1 (Obtained from Linear Technology PO 49797L). See photograph of unit under test in Appendix A. Quantity of Units: : 11 units total, 5 units for biased irradiation, 5 units for unbiased irradiation and 1 control unit. Serial numbers 878, 879, 882, 883, and 885 were biased during irradiation, serial numbers 886, 887, 891, 892, and 895 were unbiased during irradiation and serial number 896 was used as the control. See Appendix B for the radiation bias connection table. External Traveler: None required Pre-Irradiation Burn-In: Burn-In performed by Linear Devices prior to receipt by RAD. TID Dose Rate and Test Increments: 50-300rad(Si)/s with readings at pre-irradiation, 10, 20, 30, and 50krad(Si) TID Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a 168-hour 100°C anneal. Both anneals shall be performed in the same electrical bias condition as the irradiations. Electrical measurements shall be made following each anneal increment. TID Test Standard: MIL-STD-883G, Method 1019.7, Condition A TID Electrical Test Conditions: Pre-irradiation, and within one hour following each radiation exposure. Hardware: LTS2020 Tester, 2101 Family Board, 0600 Fixture, and RH1499 BGSS-061114 DUT Card. Facility and Radiation Source: Radiation Assured Devices Longmire Laboratories, Colorado Springs, CO using the JLSA 81-24 high dose rate Co60 source. Dosimetry performed by CaF TLDs traceable to NIST. RAD’s dosimetry has been audited by DSCC and RAD has been awarded Laboratory Suitability for MIL-STD-750 TM 1019.5. Irradiation and Test Temperature: All irradiations and electrical tests performed at room temperature controlled to 24°C ± 6°C per MIL STD 883.

RLAT Test Result: PASSED to 30krad(Si) but FAILED at 50krad(Si) due to degradation of the output voltage swing and short circuit current for the single-

sided 3V supply condition and the power supply rejection ratio at the single-sided 2.2V to 12V supply range

Page 2: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

2

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to ensure a worst-case test condition MIL-STD-883 TM1019.7 calls out a dose rate of 50 to 300rad(Si)/s as Condition A and further specifies that the time from the end of an incremental radiation exposure and electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to the beginning of the next incremental radiation step should be 2-hours or less. The work described in this report was performed to meet MIL-STD-883 TM1019.7 Condition A. 2.0. Radiation Test Apparatus The total ionizing dose testing described in this final report was performed using the facilities at Radiation Assured Devices’ Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 84-21 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. For high-dose rate experiments the bias boards are placed in a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required dose rate. The irradiator calibration is maintained by Radiation Assured Devices Longmire Laboratories using thermoluminescent dosimeters (TLDs)) traceable to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at RAD’s Longmire Laboratory facility. RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory Suitability under MIL STD 750. Additional details regarding Radiation Assured Devices dosimetry for TM1019 Condition A testing are available in RAD’s report to DSCC entitled: “Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation Assured Devices”

Page 3: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

3

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Figure 2.1. Radiation Assured Devices’ high dose rate Co-60 irradiator. The dose rate is obtained bypositioning the device-under-test at a fixed distance from the gamma cell. The dose rate for thisirradiator varies from approximately 120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance ofapproximately 2-feet.

Page 4: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

4

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.0. Radiation Test Conditions The RH1499MW Quad operational amplifier described in this final report was irradiated using two bias conditions, statically biased with a split 15V supply and all pins tied to ground, see Appendix A for details on biasing conditions. These devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental readings at 10, 20, 30 and 50krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The TID bias board was positioned in the Co-60 cell to provide the required dose rate range of 50 to 300rad(Si)/s and was located inside a lead-aluminum box. The lead-aluminum box is required under MIL-STD-883G TM1019.7 Section 3.4 that reads as follows: “Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by low-energy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted”. The final dose rate within the lead-aluminum box was determined based on TLD dosimetry measurements just prior to the beginning of the total dose irradiations. The final dose rate for this work was 62.7rad(Si)/s with a precision of ±5%.

Page 5: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

5

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

4.0. Tested Parameters During the radiation lot acceptance testing the following pre- and post-irradiation electrical parameters were measured (note that the full set of test conditions for the parameters listed below are shown in Appendix B):

Measured parameters and test conditions for VS=±15V:

1. Positive Supply Current 2. Negative Supply Current 3. Input Offset Voltage (Op Amp 1-4) 4. Input Offset Current (Op Amp 1-4) 5. + Input Bias Current (Op Amp 1-4) 6. - Input Bias Current (Op Amp 1-4) 7. Input Offset Voltage (Op Amp 1-4) 8. Input Offset Current (Op Amp 1-4) 9. + Input Bias Current (Op Amp 1-4) 10. - Input Bias Current (Op Amp 1-4) 11. Input Offset Voltage (Op Amp 1-4) 12. Input Offset Current (Op Amp 1-4) 13. + Input Bias Current (Op Amp 1-4) 14. - Input Bias Current (Op Amp 1-4) 15. Large Signal Voltage Gain (Op Amp 1-4) 16. Large Signal Voltage Gain (Op Amp 1-4) 17. CMRR (Op Amp 1-4) 18. CMRR Matching 1-4 19. CMRR Matching 2-3 20. PSRR (Op Amp 1-4) 21. PSRR Matching 1-4 22. PSRR Matching 2-3 23. Output Voltage Swing High (Op Amp 1-4) 24. Output Voltage Swing High (Op Amp 1-4) 25. Output Voltage Swing High (Op Amp 1-4) 26. Output Voltage Swing Low (Op Amp 1-4) 27. Output Voltage Swing Low (Op Amp 1-4) 28. Output Voltage Swing Low (Op Amp 1-4) 29. +VS Short-Circuit Current (Op Amp 1-4) 30. -VS Short-Circuit Current (Op Amp 1-4)

Measured parameters and test conditions for VS=3V: 31. Positive Supply Current

Page 6: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

6

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

32. Negative Supply Current 33. Input Offset Voltage (Op Amp 1-4) 34. Input Offset Current (Op Amp 1-4) 35. + Input Bias Current (Op Amp 1-4) 36. - Input Bias Current (Op Amp 1-4) 37. Input Offset Voltage (Op Amp 1-4) 38. Input Offset Current (Op Amp 1-4) 39. + Input Bias Current (Op Amp 1-4) 40. - Input Bias Current (Op Amp 1-4) 41. Large Signal Voltage Gain (Op Amp 1-4) 42. CMRR (Op Amp 1-4) 43. CMRR Matching 1-4 44. CMRR Matching 2-3 45. Output Voltage Swing High (Op Amp 1-4) 46. Output Voltage Swing High (Op Amp 1-4) 47. Output Voltage Swing High (Op Amp 1-4) 48. Output Voltage Swing Low (Op Amp 1-4) 49. Output Voltage Swing Low (Op Amp 1-4) 50. Output Voltage Swing Low (Op Amp 1-4) 51. +VS Short-Circuit Current (Op Amp 1-4) 52. -VS Short-Circuit Current (Op Amp 1-4)

Measured parameters and test conditions for VS=5V:

53. Positive Supply Current 54. Negative Supply Current 55. Input Offset Voltage (Op Amp 1-4) 56. Input Offset Voltage (Op Amp 1-4) 57. Input Offset Current (Op Amp 1-4) 58. Input Offset Current (Op Amp 1-4) 59. + Input Bias Current (Op Amp 1-4) 60. + Input Bias Current (Op Amp 1-4) 61. - Input Bias Current (Op Amp 1-4) 62. - Input Bias Current (Op Amp 1-4) 63. Large Signal Voltage Gain (Op Amp 1-4) 64. CMRR (Op Amp 1-4) 65. CMRR Matching 1-4 66. CMRR Matching 2-3 67. PSRR (Op Amp 1-4) 68. PSRR Matching 1-4 69. PSRR Matching 2-3

Page 7: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

7

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

70. Output Voltage Swing High (Op Amp 1-4) 71. Output Voltage Swing High (Op Amp 1-4) 72. Output Voltage Swing High (Op Amp 1-4) 73. Output Voltage Swing Low (Op Amp 1-4) 74. Output Voltage Swing Low (Op Amp 1-4) 75. Output Voltage Swing Low (Op Amp 1-4) 76. +VS Short Circuit Current (Op Amp 1-4) 77. -VS Short Circuit Current (Op Amp 1-4)

Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as “read and record” and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL values used is 2.742 per MIL HDBK 814 using one sided tolerance limits of 90/90 and a 5-piece sample size. This survival probability/level of confidence is consistent with a 22-piece sample size and zero failures analyzed using a lot tolerance percent defective (LTPD) approach. Note that the following criteria must be met for a device to pass the RLAT: following the radiation exposure the unit shall pass the specification value and the average value for the each device must pass the specification value when the KTL limits are applied. If either of these conditions is not satisfied following the radiation exposure, then the lot could be logged as an RLAT failure. Further, MIL-STD-883G, TM 1019.7 Section 3.13.1.1 Characterization test to determine if a part exhibits ELDRS” states the following: Select a minimum random sample of 21 devices from a population representative of recent production runs. Smaller sample sizes may be used if agreed upon between the parties to the test. All of the selected devices shall have undergone appropriate elevated temperature reliability screens, e.g. burn-in and high temperature storage life. Divide the samples into four groups of 5 each and use the remaining part for a control. Perform pre-irradiation electrical characterization on all parts assuring that they meet the Group A electrical tests. Irradiate 5 samples under a 0 volt bias and another 5 under the irradiation bias given in the acquisition specification at 50-300 rad(Si)/s and room temperature. Irradiate 5 samples under a 0 volt bias and another 5 under irradiation bias given in the acquisition specification at < 10mrad(Si)/s and room temperature. Irradiate all samples to the same dose levels, including 0.5 and 1.0 times the anticipated specification dose, and repeat the electrical characterization on each part at each dose level. Post irradiation electrical measurements shall be performed per paragraph 3.10 where the low dose rate test is considered Condition D. Calculate the radiation induced change in each electrical parameter (Δpara) for each sample at each radiation level. Calculate the ratio of the median Δpara at low dose rate to the median Δpara at high dose rate for each irradiation bias group at each total dose level. If this ratio exceeds 1.5 for any of the most sensitive parameters then the part is considered to be ELDRS susceptible. This test

Page 8: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

8

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

does not apply to parameters which exhibit changes that are within experimental error or whose values are below the pre-irradiation electrical specification limits at low dose rate at the specification dose. Therefore, the data in this report can be analyzed along with the low dose rate report titled “Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1499MW Quad Precision Op Amp for Linear Technology” to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. 5.0. RLAT Test Results Using the conditions stated above, the RH1499MW devices passed the RLAT test to 30krad(Si) but failed at 50krad(Si) due to degradation of the output voltage swing and short circuit current for the single-sided 3V supply condition and power supply rejection ratio at the single-sided 2.2V to 12V supply range. Most measured parameters showed no significant degradation with radiation and all parameters passed to 50krad(Si) when tested using the 15V split supply condition.

Figures 5.1 through 5.268 show plots of all the measured parameters versus total ionizing dose. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. Tables 5.1 through 5.268 show the raw data, averages, standard deviation, +KTL statistics, -KTL statistics, specification limit and Pass/Fail condition for each parameter. Appendix D provides a list of all the figures in this results section to facilitate the location of a particular parameter. As seen clearly in these tables and figures, the pre- and post-irradiation data are well within the specification even after application of the KTL statistics (with certain exceptions, as noted below). The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained under control during the course of the testing.

Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Unfortunately, not all measured parameters are well suited to this approach due to inherent large variations. The parameters measured in this report where the pre-irradiation KTL values are out of specification include Common Mode Rejection Ratio, Power Supply Rejection Ratio and Open Loop Gain, where the device exhibits extreme sensitivity to input conditions, resulting in a very large standard deviation and a statistical error often greater than the measured value. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach.

Page 9: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

9

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E-03

6.00E-03

7.00E-03

8.00E-03

9.00E-03

1.00E-02

1.10E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Supp

ly C

urre

nt (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.1. Plot of Positive Supply Current (A) versus total dose. The data show no significant change withradiation. The solid diamonds are the average of the measured data points for the sample irradiated underelectrical bias while the shaded diamonds are the average of the measured data points for the units irradiatedwith all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 10: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

10

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.1. Raw data for Positive Supply Current (A) versus total dose, including the statisticalanalysis, specification and the status of the testing (pass/fail).

Positive Supply Current (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.35E-03 7.32E-03 7.29E-03 7.25E-03 7.22E-03 7.23E-03 7.19E-03879 7.30E-03 7.23E-03 7.22E-03 7.15E-03 7.15E-03 7.22E-03 7.21E-03882 7.43E-03 7.36E-03 7.34E-03 7.30E-03 7.27E-03 7.27E-03 7.27E-03883 7.14E-03 7.04E-03 7.00E-03 6.97E-03 6.90E-03 6.91E-03 6.93E-03885 7.25E-03 7.16E-03 7.13E-03 7.14E-03 7.06E-03 7.07E-03 7.08E-03886 7.39E-03 7.33E-03 7.32E-03 7.30E-03 7.28E-03 7.26E-03 7.30E-03887 7.30E-03 7.25E-03 7.24E-03 7.21E-03 7.17E-03 7.17E-03 7.22E-03891 7.38E-03 7.33E-03 7.32E-03 7.30E-03 7.27E-03 7.25E-03 7.30E-03892 7.17E-03 7.14E-03 7.13E-03 7.10E-03 7.06E-03 7.05E-03 7.11E-03895 7.36E-03 7.31E-03 7.30E-03 7.28E-03 7.23E-03 7.24E-03 7.28E-03896 7.81E-03 7.42E-03 7.42E-03 7.42E-03 7.44E-03 7.44E-03 7.42E-03

Biased StatisticsAverage Biased 7.29E-03 7.22E-03 7.20E-03 7.16E-03 7.12E-03 7.14E-03 7.14E-03Std Dev Biased 1.09E-04 1.28E-04 1.35E-04 1.27E-04 1.46E-04 1.49E-04 1.34E-04Ps90%/90% (+KTL) Biased 7.59E-03 7.57E-03 7.57E-03 7.51E-03 7.52E-03 7.55E-03 7.50E-03Ps90%/90% (-KTL) Biased 7.00E-03 6.87E-03 6.83E-03 6.81E-03 6.72E-03 6.73E-03 6.77E-03Un-Biased StatisticsAverage Un-Biased 7.32E-03 7.27E-03 7.26E-03 7.24E-03 7.20E-03 7.19E-03 7.24E-03Std Dev Un-Biased 9.08E-05 8.07E-05 8.07E-05 8.56E-05 9.04E-05 8.79E-05 8.07E-05Ps90%/90% (+KTL) Un-Biased 7.57E-03 7.49E-03 7.48E-03 7.47E-03 7.45E-03 7.44E-03 7.46E-03Ps90%/90% (-KTL) Un-Biased 7.07E-03 7.05E-03 7.04E-03 7.00E-03 6.95E-03 6.95E-03 7.02E-03Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 11: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

11

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.10E-02

-1.00E-02

-9.00E-03

-8.00E-03

-7.00E-03

-6.00E-03

-5.00E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Su

pply

Cur

rent

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.2. Plot of Negative Supply Current (A) versus total dose. The data show no significant change withradiation. The solid diamonds are the average of the measured data points for the sample irradiated underelectrical bias while the shaded diamonds are the average of the measured data points for the units irradiatedwith all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 12: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

12

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.2. Raw data for Negative Supply Current (A) versus total dose, including thestatistical analysis, specification and the status of the testing (pass/fail).

Negative Supply Current (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -7.37E-03 -7.33E-03 -7.30E-03 -7.27E-03 -7.24E-03 -7.25E-03 -7.21E-03879 -7.32E-03 -7.25E-03 -7.24E-03 -7.17E-03 -7.16E-03 -7.24E-03 -7.23E-03882 -7.45E-03 -7.38E-03 -7.35E-03 -7.32E-03 -7.29E-03 -7.29E-03 -7.29E-03883 -7.16E-03 -7.06E-03 -7.02E-03 -6.99E-03 -6.92E-03 -6.93E-03 -6.95E-03885 -7.27E-03 -7.18E-03 -7.14E-03 -7.16E-03 -7.08E-03 -7.09E-03 -7.10E-03886 -7.41E-03 -7.35E-03 -7.34E-03 -7.33E-03 -7.30E-03 -7.28E-03 -7.32E-03887 -7.32E-03 -7.27E-03 -7.26E-03 -7.23E-03 -7.19E-03 -7.18E-03 -7.24E-03891 -7.40E-03 -7.35E-03 -7.34E-03 -7.32E-03 -7.29E-03 -7.27E-03 -7.32E-03892 -7.19E-03 -7.16E-03 -7.15E-03 -7.12E-03 -7.08E-03 -7.07E-03 -7.13E-03895 -7.38E-03 -7.33E-03 -7.32E-03 -7.29E-03 -7.25E-03 -7.26E-03 -7.30E-03896 -7.81E-03 -7.43E-03 -7.44E-03 -7.44E-03 -7.46E-03 -7.46E-03 -7.44E-03

Biased StatisticsAverage Biased -7.31E-03 -7.24E-03 -7.21E-03 -7.18E-03 -7.14E-03 -7.16E-03 -7.16E-03Std Dev Biased 1.09E-04 1.26E-04 1.32E-04 1.27E-04 1.46E-04 1.49E-04 1.34E-04Ps90%/90% (+KTL) Biased -7.02E-03 -6.89E-03 -6.85E-03 -6.83E-03 -6.74E-03 -6.75E-03 -6.79E-03Ps90%/90% (-KTL) Biased -7.61E-03 -7.59E-03 -7.57E-03 -7.53E-03 -7.54E-03 -7.57E-03 -7.52E-03Un-Biased StatisticsAverage Un-Biased -7.34E-03 -7.29E-03 -7.28E-03 -7.26E-03 -7.22E-03 -7.21E-03 -7.26E-03Std Dev Un-Biased 9.08E-05 8.07E-05 8.07E-05 8.64E-05 9.04E-05 8.87E-05 8.07E-05Ps90%/90% (+KTL) Un-Biased -7.09E-03 -7.07E-03 -7.06E-03 -7.02E-03 -6.97E-03 -6.97E-03 -7.04E-03Ps90%/90% (-KTL) Un-Biased -7.59E-03 -7.51E-03 -7.50E-03 -7.49E-03 -7.47E-03 -7.46E-03 -7.48E-03Specification MIN -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 13: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

13

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

0 V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.3. Plot of Input Offset Voltage @ +/- 15V, VCM= 0 V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 14: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

14

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.3. Raw data for Input Offset Voltage @ +/- 15V, VCM= 0 V #1 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 0 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.10E-04 -2.23E-04 -2.12E-04 -2.03E-04 -2.01E-04 -2.05E-04 -2.31E-04879 -1.07E-04 -1.40E-04 -1.26E-04 -1.39E-04 -1.51E-04 -1.48E-04 -1.40E-04882 -1.56E-04 -1.64E-04 -1.61E-04 -1.63E-04 -1.62E-04 -1.57E-04 -1.76E-04883 -1.30E-04 -1.46E-04 -1.43E-04 -1.26E-04 -1.39E-04 -1.41E-04 -1.53E-04885 -2.92E-04 -3.04E-04 -2.95E-04 -3.00E-04 -2.94E-04 -2.97E-04 -3.06E-04886 1.29E-04 1.06E-04 9.85E-05 9.55E-05 9.00E-05 8.64E-05 8.54E-05887 -2.65E-04 -2.79E-04 -2.86E-04 -2.88E-04 -2.98E-04 -2.96E-04 -2.99E-04891 -1.08E-04 -1.24E-04 -1.29E-04 -1.35E-04 -1.40E-04 -1.42E-04 -1.48E-04892 -2.63E-04 -2.74E-04 -2.78E-04 -2.85E-04 -2.95E-04 -2.91E-04 -2.94E-04895 -1.38E-04 -1.58E-04 -1.61E-04 -1.66E-04 -1.79E-04 -1.79E-04 -1.72E-04896 1.33E-04 9.98E-05 9.97E-05 1.01E-04 1.02E-04 1.02E-04 1.01E-04

Biased StatisticsAverage Biased -1.79E-04 -1.95E-04 -1.87E-04 -1.86E-04 -1.89E-04 -1.89E-04 -2.01E-04Std Dev Biased 7.39E-05 6.92E-05 6.83E-05 7.03E-05 6.28E-05 6.53E-05 6.81E-05Ps90%/90% (+KTL) Biased 2.35E-05 -5.54E-06 -2.36E-07 6.78E-06 -1.71E-05 -1.04E-05 -1.48E-05Ps90%/90% (-KTL) Biased -3.82E-04 -3.85E-04 -3.75E-04 -3.79E-04 -3.62E-04 -3.68E-04 -3.88E-04Un-Biased StatisticsAverage Un-Biased -1.29E-04 -1.46E-04 -1.51E-04 -1.55E-04 -1.64E-04 -1.64E-04 -1.65E-04Std Dev Un-Biased 1.61E-04 1.56E-04 1.56E-04 1.56E-04 1.59E-04 1.56E-04 1.56E-04Ps90%/90% (+KTL) Un-Biased 3.11E-04 2.83E-04 2.76E-04 2.73E-04 2.70E-04 2.62E-04 2.63E-04Ps90%/90% (-KTL) Un-Biased -5.70E-04 -5.75E-04 -5.78E-04 -5.84E-04 -5.99E-04 -5.91E-04 -5.94E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 15: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

15

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

0 V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.4. Plot of Input Offset Voltage @ +/- 15V, VCM= 0 V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 16: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

16

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.4. Raw data for Input Offset Voltage @ +/- 15V, VCM= 0 V #2 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 0 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -4.32E-04 -4.48E-04 -4.43E-04 -4.02E-04 -3.63E-04 -4.17E-04 -4.50E-04879 -1.87E-04 -1.86E-04 -1.68E-04 -1.76E-04 -1.87E-04 -1.82E-04 -1.91E-04882 -8.38E-05 -1.06E-04 -1.10E-04 -1.07E-04 -1.06E-04 -1.06E-04 -1.28E-04883 -7.17E-05 -8.94E-05 -7.85E-05 -5.81E-05 -6.51E-05 -2.68E-05 -9.27E-05885 -6.39E-05 -6.00E-05 -3.08E-05 -5.84E-05 -6.28E-05 -7.24E-05 -8.44E-05886 2.13E-04 1.91E-04 1.86E-04 1.80E-04 1.76E-04 1.75E-04 1.78E-04887 -3.64E-04 -3.65E-04 -3.65E-04 -3.70E-04 -3.77E-04 -3.79E-04 -3.97E-04891 9.86E-05 9.18E-05 9.06E-05 8.58E-05 7.83E-05 7.40E-05 8.18E-05892 5.85E-05 4.86E-05 4.79E-05 4.64E-05 4.04E-05 3.87E-05 2.31E-05895 -3.89E-05 -5.31E-05 -5.59E-05 -5.96E-05 -6.31E-05 -6.54E-05 -7.27E-05896 -1.94E-05 -3.85E-05 -3.74E-05 -3.72E-05 -3.75E-05 -3.80E-05 -3.78E-05

Biased StatisticsAverage Biased -1.68E-04 -1.78E-04 -1.66E-04 -1.60E-04 -1.57E-04 -1.61E-04 -1.89E-04Std Dev Biased 1.56E-04 1.58E-04 1.63E-04 1.43E-04 1.26E-04 1.54E-04 1.52E-04Ps90%/90% (+KTL) Biased 2.59E-04 2.56E-04 2.80E-04 2.33E-04 1.88E-04 2.61E-04 2.27E-04Ps90%/90% (-KTL) Biased -5.95E-04 -6.12E-04 -6.12E-04 -5.53E-04 -5.02E-04 -5.83E-04 -6.06E-04Un-Biased StatisticsAverage Un-Biased -6.46E-06 -1.72E-05 -1.93E-05 -2.34E-05 -2.91E-05 -3.14E-05 -3.75E-05Std Dev Un-Biased 2.19E-04 2.13E-04 2.12E-04 2.12E-04 2.13E-04 2.13E-04 2.21E-04Ps90%/90% (+KTL) Un-Biased 5.94E-04 5.67E-04 5.62E-04 5.58E-04 5.54E-04 5.52E-04 5.68E-04Ps90%/90% (-KTL) Un-Biased -6.07E-04 -6.02E-04 -6.01E-04 -6.05E-04 -6.12E-04 -6.15E-04 -6.43E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 17: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

17

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

0 V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.5. Plot of Input Offset Voltage @ +/- 15V, VCM= 0 V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 18: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

18

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.5. Raw data for Input Offset Voltage @ +/- 15V, VCM= 0 V #3 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 0 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -6.36E-05 -8.71E-05 -8.03E-05 -7.40E-05 -7.33E-05 -7.50E-05 -9.22E-05879 -5.37E-05 -8.89E-05 -6.77E-05 -8.33E-05 -9.09E-05 -9.02E-05 -9.16E-05882 -1.78E-04 -2.06E-04 -1.96E-04 -1.97E-04 -1.92E-04 -1.98E-04 -2.19E-04883 1.21E-04 9.43E-05 9.58E-05 1.15E-04 9.29E-05 9.87E-05 6.65E-05885 -1.69E-04 -1.86E-04 -1.79E-04 -1.82E-04 -1.89E-04 -1.89E-04 -2.10E-04886 -2.57E-04 -2.73E-04 -2.76E-04 -2.81E-04 -2.86E-04 -2.84E-04 -2.85E-04887 -3.60E-04 -3.65E-04 -3.70E-04 -3.79E-04 -3.96E-04 -3.98E-04 -3.71E-04891 -1.23E-04 -1.38E-04 -1.38E-04 -1.43E-04 -1.48E-04 -1.50E-04 -1.55E-04892 2.53E-05 1.25E-05 1.20E-05 5.11E-06 -4.40E-07 -8.00E-08 -4.19E-06895 -4.47E-05 -6.19E-05 -6.49E-05 -6.70E-05 -6.94E-05 -7.04E-05 -6.92E-05896 3.29E-04 2.71E-04 2.69E-04 2.72E-04 2.75E-04 2.75E-04 2.73E-04

Biased StatisticsAverage Biased -6.88E-05 -9.46E-05 -8.53E-05 -8.44E-05 -9.04E-05 -9.06E-05 -1.09E-04Std Dev Biased 1.21E-04 1.19E-04 1.16E-04 1.25E-04 1.16E-04 1.20E-04 1.16E-04Ps90%/90% (+KTL) Biased 2.62E-04 2.31E-04 2.33E-04 2.58E-04 2.28E-04 2.37E-04 2.09E-04Ps90%/90% (-KTL) Biased -4.00E-04 -4.20E-04 -4.04E-04 -4.26E-04 -4.09E-04 -4.19E-04 -4.28E-04Un-Biased StatisticsAverage Un-Biased -1.52E-04 -1.65E-04 -1.67E-04 -1.73E-04 -1.80E-04 -1.80E-04 -1.77E-04Std Dev Un-Biased 1.56E-04 1.54E-04 1.55E-04 1.56E-04 1.61E-04 1.61E-04 1.51E-04Ps90%/90% (+KTL) Un-Biased 2.77E-04 2.56E-04 2.58E-04 2.56E-04 2.61E-04 2.61E-04 2.37E-04Ps90%/90% (-KTL) Un-Biased -5.81E-04 -5.86E-04 -5.93E-04 -6.02E-04 -6.21E-04 -6.21E-04 -5.91E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 19: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

19

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

0 V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.6. Plot of Input Offset Voltage @ +/- 15V, VCM= 0 V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 20: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

20

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.6. Raw data for Input Offset Voltage @ +/- 15V, VCM= 0 V #4 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 0 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.46E-04 -2.68E-04 -2.56E-04 -2.55E-04 -2.45E-04 -2.46E-04 -2.61E-04879 -1.51E-04 -1.80E-04 -1.65E-04 -1.79E-04 -1.85E-04 -1.80E-04 -1.98E-04882 -7.84E-05 -9.96E-05 -8.39E-05 -7.88E-05 -7.32E-05 -7.65E-05 -8.75E-05883 -1.94E-04 -2.07E-04 -2.01E-04 -1.77E-04 -2.00E-04 -1.99E-04 -2.29E-04885 2.10E-06 -2.71E-05 -2.21E-05 -1.98E-05 -2.64E-05 -3.09E-05 -6.17E-05886 7.24E-05 4.86E-05 4.16E-05 3.56E-05 3.02E-05 2.56E-05 2.65E-05887 -2.06E-04 -2.18E-04 -2.25E-04 -2.28E-04 -2.37E-04 -2.36E-04 -2.37E-04891 -3.60E-05 -5.49E-05 -5.77E-05 -6.10E-05 -6.70E-05 -6.86E-05 -6.76E-05892 7.60E-05 7.63E-05 7.52E-05 6.53E-05 7.05E-05 6.93E-05 6.34E-05895 -5.82E-05 -7.29E-05 -8.09E-05 -8.66E-05 -1.02E-04 -1.04E-04 -9.88E-05896 7.45E-05 3.83E-05 4.11E-05 3.98E-05 4.10E-05 4.15E-05 4.36E-05

Biased StatisticsAverage Biased -1.33E-04 -1.56E-04 -1.46E-04 -1.42E-04 -1.46E-04 -1.47E-04 -1.68E-04Std Dev Biased 9.74E-05 9.43E-05 9.31E-05 9.25E-05 9.19E-05 8.97E-05 8.81E-05Ps90%/90% (+KTL) Biased 1.34E-04 1.02E-04 1.10E-04 1.12E-04 1.06E-04 9.92E-05 7.42E-05Ps90%/90% (-KTL) Biased -4.00E-04 -4.15E-04 -4.01E-04 -3.95E-04 -3.98E-04 -3.92E-04 -4.09E-04Un-Biased StatisticsAverage Un-Biased -3.03E-05 -4.43E-05 -4.93E-05 -5.49E-05 -6.10E-05 -6.27E-05 -6.28E-05Std Dev Un-Biased 1.16E-04 1.17E-04 1.18E-04 1.16E-04 1.21E-04 1.19E-04 1.18E-04Ps90%/90% (+KTL) Un-Biased 2.86E-04 2.76E-04 2.74E-04 2.62E-04 2.70E-04 2.64E-04 2.61E-04Ps90%/90% (-KTL) Un-Biased -3.47E-04 -3.64E-04 -3.73E-04 -3.72E-04 -3.92E-04 -3.90E-04 -3.86E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 21: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

21

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

0 V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.7. Plot of Input Offset Current @ +/- 15V, VCM= 0 V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 22: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

22

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.7. Raw data for Input Offset Current @ +/- 15V, VCM= 0 V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 0 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.23E-09 1.13E-09 1.46E-09 1.61E-09 8.14E-10 8.82E-10 1.09E-09879 -5.10E-10 -4.54E-10 -5.12E-10 -9.22E-10 7.44E-10 3.68E-10 7.70E-11882 -3.80E-09 -4.03E-09 -3.82E-09 -4.18E-09 -4.03E-09 -3.54E-09 -3.64E-09883 -2.72E-09 -2.36E-09 -2.23E-09 -2.51E-09 -3.08E-09 -2.71E-09 -2.86E-09885 -2.10E-09 -2.95E-09 -2.30E-09 -1.14E-09 -1.61E-09 -2.29E-09 -2.08E-09886 3.31E-09 3.13E-09 2.76E-09 2.35E-09 2.36E-09 2.86E-09 2.59E-09887 1.79E-09 1.60E-09 1.41E-09 1.44E-09 1.27E-09 1.27E-09 1.48E-09891 -1.14E-09 -1.12E-09 -1.35E-09 -1.19E-09 -7.98E-10 -9.73E-10 -3.31E-09892 -2.29E-09 -2.75E-09 -2.68E-09 -2.47E-09 -2.66E-09 -2.87E-09 -2.42E-09895 5.13E-10 1.04E-09 1.09E-09 1.07E-09 1.48E-09 1.51E-09 1.27E-09896 3.00E-10 3.08E-10 2.99E-10 3.00E-10 3.06E-10 3.26E-10 3.42E-10

Biased StatisticsAverage Biased -1.58E-09 -1.73E-09 -1.48E-09 -1.43E-09 -1.43E-09 -1.46E-09 -1.48E-09Std Dev Biased 1.97E-09 2.06E-09 2.02E-09 2.14E-09 2.20E-09 1.96E-09 2.00E-09Ps90%/90% (+KTL) Biased 3.83E-09 3.91E-09 4.05E-09 4.44E-09 4.59E-09 3.92E-09 3.99E-09Ps90%/90% (-KTL) Biased -6.98E-09 -7.37E-09 -7.01E-09 -7.29E-09 -7.46E-09 -6.84E-09 -6.95E-09Un-Biased StatisticsAverage Un-Biased 4.36E-10 3.80E-10 2.48E-10 2.38E-10 3.29E-10 3.59E-10 -7.78E-11Std Dev Un-Biased 2.24E-09 2.32E-09 2.21E-09 2.00E-09 2.04E-09 2.27E-09 2.61E-09Ps90%/90% (+KTL) Un-Biased 6.57E-09 6.74E-09 6.30E-09 5.72E-09 5.91E-09 6.58E-09 7.09E-09Ps90%/90% (-KTL) Un-Biased -5.70E-09 -5.98E-09 -5.81E-09 -5.24E-09 -5.25E-09 -5.87E-09 -7.24E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 23: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

23

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

0 V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.8. Plot of Input Offset Current @ +/- 15V, VCM= 0 V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 24: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

24

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.8. Raw data for Input Offset Current @ +/- 15V, VCM= 0 V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 0 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -1.97E-09 -2.21E-09 -2.40E-09 1.24E-09 5.33E-09 -2.14E-09 -1.88E-09879 -6.37E-09 -6.63E-09 -6.59E-09 -5.99E-09 -4.94E-09 -5.06E-09 -5.66E-09882 -4.11E-09 -4.24E-09 -4.75E-09 -4.50E-09 -4.45E-09 -4.72E-09 -4.41E-09883 -2.31E-10 -7.40E-10 -6.96E-10 -1.00E-10 5.05E-10 6.15E-09 -4.22E-10885 -4.20E-11 1.71E-09 3.14E-09 2.04E-09 -2.56E-10 2.31E-10 2.23E-10886 -4.21E-10 -3.39E-10 2.23E-10 1.32E-10 5.62E-10 6.12E-10 -2.40E-11887 -7.10E-09 -7.38E-09 -6.61E-09 -7.24E-09 -7.24E-09 -7.49E-09 -7.21E-09891 -1.07E-09 -1.58E-09 -4.74E-10 -1.73E-09 -1.46E-09 -1.29E-09 -1.33E-09892 1.20E-09 1.07E-09 1.02E-09 1.60E-09 1.36E-09 1.28E-09 1.37E-09895 1.86E-09 1.60E-09 1.67E-09 1.19E-09 1.91E-09 1.54E-09 1.23E-09896 1.02E-09 9.89E-10 1.02E-09 9.90E-10 9.93E-10 1.02E-09 9.88E-10

Biased StatisticsAverage Biased -2.54E-09 -2.42E-09 -2.26E-09 -1.46E-09 -7.60E-10 -1.11E-09 -2.43E-09Std Dev Biased 2.69E-09 3.20E-09 3.76E-09 3.58E-09 4.18E-09 4.59E-09 2.54E-09Ps90%/90% (+KTL) Biased 4.84E-09 6.35E-09 8.05E-09 8.34E-09 1.07E-08 1.15E-08 4.53E-09Ps90%/90% (-KTL) Biased -9.93E-09 -1.12E-08 -1.26E-08 -1.13E-08 -1.22E-08 -1.37E-08 -9.39E-09Un-Biased StatisticsAverage Un-Biased -1.11E-09 -1.33E-09 -8.35E-10 -1.21E-09 -9.74E-10 -1.07E-09 -1.19E-09Std Dev Un-Biased 3.55E-09 3.61E-09 3.33E-09 3.61E-09 3.73E-09 3.76E-09 3.54E-09Ps90%/90% (+KTL) Un-Biased 8.64E-09 8.56E-09 8.28E-09 8.69E-09 9.25E-09 9.23E-09 8.51E-09Ps90%/90% (-KTL) Un-Biased -1.09E-08 -1.12E-08 -9.95E-09 -1.11E-08 -1.12E-08 -1.14E-08 -1.09E-08Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 25: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

25

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

0 V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.9. Plot of Input Offset Current @ +/- 15V, VCM= 0 V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 26: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

26

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.9. Raw data for Input Offset Current @ +/- 15V, VCM= 0 V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 0 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.66E-09 4.50E-09 4.67E-09 4.78E-09 4.49E-09 4.40E-09 5.18E-09879 -5.05E-09 -5.53E-09 -5.22E-09 -5.51E-09 -4.24E-09 -4.31E-09 -4.21E-09882 -1.19E-09 -1.15E-09 -1.56E-09 -1.85E-09 -2.07E-09 -2.27E-09 -1.80E-09883 2.66E-09 2.55E-09 2.53E-09 3.06E-09 2.07E-09 2.11E-09 2.25E-09885 3.99E-09 3.77E-09 3.67E-09 4.61E-09 4.34E-09 3.57E-09 4.20E-09886 1.29E-09 8.57E-10 1.47E-09 1.10E-09 1.82E-09 1.57E-09 1.25E-09887 -3.83E-09 -3.80E-09 -3.47E-09 -3.89E-09 -3.92E-09 -3.91E-09 -3.83E-09891 1.76E-09 1.62E-09 1.98E-09 1.89E-09 9.38E-10 1.63E-09 1.66E-09892 2.75E-10 4.27E-10 8.22E-10 2.82E-10 9.10E-11 4.24E-10 4.20E-10895 1.38E-09 1.10E-09 9.09E-10 1.55E-09 1.13E-09 1.82E-09 1.62E-09896 1.54E-09 1.64E-09 1.69E-09 1.66E-09 1.64E-09 1.70E-09 1.62E-09

Biased StatisticsAverage Biased 1.01E-09 8.30E-10 8.18E-10 1.02E-09 9.19E-10 7.00E-10 1.12E-09Std Dev Biased 4.08E-09 4.17E-09 4.12E-09 4.53E-09 3.91E-09 3.80E-09 4.01E-09Ps90%/90% (+KTL) Biased 1.22E-08 1.23E-08 1.21E-08 1.34E-08 1.17E-08 1.11E-08 1.21E-08Ps90%/90% (-KTL) Biased -1.02E-08 -1.06E-08 -1.05E-08 -1.14E-08 -9.81E-09 -9.72E-09 -9.86E-09Un-Biased StatisticsAverage Un-Biased 1.74E-10 4.06E-11 3.40E-10 1.85E-10 1.10E-11 3.06E-10 2.24E-10Std Dev Un-Biased 2.31E-09 2.19E-09 2.18E-09 2.36E-09 2.28E-09 2.42E-09 2.32E-09Ps90%/90% (+KTL) Un-Biased 6.50E-09 6.05E-09 6.32E-09 6.65E-09 6.27E-09 6.95E-09 6.59E-09Ps90%/90% (-KTL) Un-Biased -6.15E-09 -5.97E-09 -5.64E-09 -6.28E-09 -6.24E-09 -6.33E-09 -6.14E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 27: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

27

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

0 V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.10. Plot of Input Offset Current @ +/- 15V, VCM= 0 V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 28: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

28

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.10. Raw data for Input Offset Current @ +/- 15V, VCM= 0 V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 0 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.67E-09 -3.79E-09 -2.55E-09 -2.90E-09 -3.05E-09 -2.96E-09 -2.98E-09879 -4.11E-09 -4.56E-09 -4.31E-09 -4.05E-09 -2.85E-09 -3.53E-09 -3.47E-09882 1.75E-09 1.65E-09 1.31E-09 1.37E-09 1.61E-09 1.34E-09 1.53E-09883 -3.57E-09 -3.99E-09 -4.07E-09 -2.43E-09 -2.90E-09 -3.16E-09 -3.65E-09885 3.92E-10 3.72E-10 9.03E-10 2.13E-09 9.03E-10 1.16E-09 9.31E-10886 -5.32E-10 -8.45E-10 -5.64E-10 -1.04E-09 -1.02E-09 -1.30E-09 -9.79E-10887 -2.23E-09 -2.05E-09 -2.43E-09 -2.61E-09 -2.21E-09 -2.53E-09 -2.81E-09891 -3.86E-09 -3.73E-09 -3.88E-09 -4.14E-09 -3.84E-09 -3.76E-09 -3.82E-09892 1.53E-09 1.42E-09 1.68E-09 1.86E-09 1.76E-09 1.19E-09 7.25E-10895 -4.17E-09 -4.28E-09 -4.27E-09 -4.23E-09 -3.93E-09 -4.76E-09 -4.64E-09896 3.79E-09 3.93E-09 3.95E-09 3.96E-09 3.93E-09 3.91E-09 3.92E-09

Biased StatisticsAverage Biased -1.84E-09 -2.06E-09 -1.74E-09 -1.18E-09 -1.26E-09 -1.43E-09 -1.53E-09Std Dev Biased 2.71E-09 2.86E-09 2.69E-09 2.75E-09 2.31E-09 2.45E-09 2.54E-09Ps90%/90% (+KTL) Biased 5.59E-09 5.77E-09 5.63E-09 6.36E-09 5.07E-09 5.30E-09 5.44E-09Ps90%/90% (-KTL) Biased -9.27E-09 -9.90E-09 -9.12E-09 -8.72E-09 -7.58E-09 -8.16E-09 -8.49E-09Un-Biased StatisticsAverage Un-Biased -1.85E-09 -1.90E-09 -1.89E-09 -2.03E-09 -1.85E-09 -2.23E-09 -2.30E-09Std Dev Un-Biased 2.38E-09 2.30E-09 2.47E-09 2.54E-09 2.35E-09 2.31E-09 2.18E-09Ps90%/90% (+KTL) Un-Biased 4.68E-09 4.41E-09 4.89E-09 4.92E-09 4.60E-09 4.11E-09 3.66E-09Ps90%/90% (-KTL) Un-Biased -8.38E-09 -8.20E-09 -8.67E-09 -8.99E-09 -8.30E-09 -8.58E-09 -8.27E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 29: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

29

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

0 V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.11. Plot of Positive Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 30: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

30

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.11. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.36E-07 -2.40E-07 -2.45E-07 -2.49E-07 -2.55E-07 -2.46E-07 -2.43E-07879 -2.49E-07 -2.54E-07 -2.58E-07 -2.62E-07 -2.76E-07 -2.61E-07 -2.57E-07882 -2.60E-07 -2.67E-07 -2.71E-07 -2.75E-07 -2.81E-07 -2.72E-07 -2.67E-07883 -2.61E-07 -2.68E-07 -2.71E-07 -2.75E-07 -2.80E-07 -2.72E-07 -2.67E-07885 -2.45E-07 -2.52E-07 -2.56E-07 -2.64E-07 -2.66E-07 -2.58E-07 -2.53E-07886 -2.36E-07 -2.44E-07 -2.51E-07 -2.56E-07 -2.65E-07 -2.62E-07 -2.48E-07887 -2.55E-07 -2.63E-07 -2.69E-07 -2.74E-07 -2.84E-07 -2.80E-07 -2.66E-07891 -2.62E-07 -2.70E-07 -2.75E-07 -2.80E-07 -2.87E-07 -2.85E-07 -2.73E-07892 -2.60E-07 -2.66E-07 -2.70E-07 -2.75E-07 -2.82E-07 -2.80E-07 -2.68E-07895 -2.59E-07 -2.66E-07 -2.72E-07 -2.77E-07 -2.87E-07 -2.82E-07 -2.69E-07896 -2.58E-07 -2.78E-07 -2.78E-07 -2.78E-07 -2.77E-07 -2.77E-07 -2.78E-07

Biased StatisticsAverage Biased -2.50E-07 -2.56E-07 -2.60E-07 -2.65E-07 -2.72E-07 -2.62E-07 -2.58E-07Std Dev Biased 1.06E-08 1.15E-08 1.12E-08 1.07E-08 1.11E-08 1.08E-08 1.00E-08Ps90%/90% (+KTL) Biased -2.21E-07 -2.24E-07 -2.30E-07 -2.36E-07 -2.41E-07 -2.32E-07 -2.30E-07Ps90%/90% (-KTL) Biased -2.79E-07 -2.88E-07 -2.91E-07 -2.94E-07 -3.02E-07 -2.91E-07 -2.85E-07Un-Biased StatisticsAverage Un-Biased -2.54E-07 -2.62E-07 -2.67E-07 -2.72E-07 -2.81E-07 -2.78E-07 -2.65E-07Std Dev Un-Biased 1.04E-08 1.01E-08 9.56E-09 9.46E-09 9.31E-09 9.27E-09 9.65E-09Ps90%/90% (+KTL) Un-Biased -2.26E-07 -2.34E-07 -2.41E-07 -2.46E-07 -2.55E-07 -2.52E-07 -2.38E-07Ps90%/90% (-KTL) Un-Biased -2.83E-07 -2.90E-07 -2.94E-07 -2.98E-07 -3.06E-07 -3.03E-07 -2.91E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 31: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

31

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

0 V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.12. Plot of Positive Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 32: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

32

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.12. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.46E-07 -2.50E-07 -2.55E-07 -2.58E-07 -2.63E-07 -2.56E-07 -2.54E-07879 -2.58E-07 -2.60E-07 -2.61E-07 -2.64E-07 -2.76E-07 -2.66E-07 -2.64E-07882 -2.43E-07 -2.51E-07 -2.55E-07 -2.58E-07 -2.63E-07 -2.55E-07 -2.51E-07883 -2.44E-07 -2.50E-07 -2.54E-07 -2.56E-07 -2.60E-07 -2.52E-07 -2.48E-07885 -2.50E-07 -2.56E-07 -2.60E-07 -2.69E-07 -2.70E-07 -2.62E-07 -2.57E-07886 -2.41E-07 -2.49E-07 -2.55E-07 -2.60E-07 -2.69E-07 -2.65E-07 -2.52E-07887 -2.56E-07 -2.62E-07 -2.65E-07 -2.69E-07 -2.75E-07 -2.74E-07 -2.64E-07891 -2.40E-07 -2.48E-07 -2.53E-07 -2.58E-07 -2.67E-07 -2.64E-07 -2.51E-07892 -2.45E-07 -2.52E-07 -2.57E-07 -2.62E-07 -2.69E-07 -2.67E-07 -2.54E-07895 -2.29E-07 -2.36E-07 -2.42E-07 -2.47E-07 -2.56E-07 -2.52E-07 -2.40E-07896 -2.38E-07 -2.56E-07 -2.56E-07 -2.56E-07 -2.55E-07 -2.55E-07 -2.56E-07

Biased StatisticsAverage Biased -2.48E-07 -2.53E-07 -2.57E-07 -2.61E-07 -2.66E-07 -2.58E-07 -2.55E-07Std Dev Biased 5.83E-09 4.49E-09 3.54E-09 5.24E-09 6.37E-09 5.76E-09 6.14E-09Ps90%/90% (+KTL) Biased -2.32E-07 -2.41E-07 -2.47E-07 -2.47E-07 -2.49E-07 -2.42E-07 -2.38E-07Ps90%/90% (-KTL) Biased -2.64E-07 -2.66E-07 -2.67E-07 -2.75E-07 -2.84E-07 -2.74E-07 -2.72E-07Un-Biased StatisticsAverage Un-Biased -2.42E-07 -2.50E-07 -2.54E-07 -2.59E-07 -2.67E-07 -2.65E-07 -2.52E-07Std Dev Un-Biased 9.80E-09 9.14E-09 8.43E-09 8.00E-09 7.17E-09 8.00E-09 8.61E-09Ps90%/90% (+KTL) Un-Biased -2.15E-07 -2.24E-07 -2.31E-07 -2.37E-07 -2.47E-07 -2.43E-07 -2.29E-07Ps90%/90% (-KTL) Un-Biased -2.69E-07 -2.75E-07 -2.77E-07 -2.81E-07 -2.87E-07 -2.86E-07 -2.76E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 33: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

33

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

0 V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.13. Plot of Positive Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 34: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

34

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.13. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.43E-07 -2.47E-07 -2.51E-07 -2.56E-07 -2.61E-07 -2.52E-07 -2.50E-07879 -2.52E-07 -2.54E-07 -2.56E-07 -2.59E-07 -2.70E-07 -2.61E-07 -2.58E-07882 -2.43E-07 -2.50E-07 -2.54E-07 -2.58E-07 -2.64E-07 -2.56E-07 -2.51E-07883 -2.40E-07 -2.46E-07 -2.49E-07 -2.53E-07 -2.57E-07 -2.49E-07 -2.45E-07885 -2.53E-07 -2.59E-07 -2.64E-07 -2.72E-07 -2.73E-07 -2.65E-07 -2.60E-07886 -2.36E-07 -2.44E-07 -2.50E-07 -2.55E-07 -2.63E-07 -2.60E-07 -2.47E-07887 -2.53E-07 -2.59E-07 -2.62E-07 -2.65E-07 -2.72E-07 -2.71E-07 -2.60E-07891 -2.34E-07 -2.43E-07 -2.47E-07 -2.52E-07 -2.62E-07 -2.58E-07 -2.45E-07892 -2.39E-07 -2.46E-07 -2.51E-07 -2.56E-07 -2.64E-07 -2.61E-07 -2.48E-07895 -2.26E-07 -2.33E-07 -2.39E-07 -2.43E-07 -2.52E-07 -2.48E-07 -2.36E-07896 -2.37E-07 -2.55E-07 -2.55E-07 -2.55E-07 -2.54E-07 -2.54E-07 -2.54E-07

Biased StatisticsAverage Biased -2.46E-07 -2.51E-07 -2.55E-07 -2.60E-07 -2.65E-07 -2.57E-07 -2.53E-07Std Dev Biased 6.09E-09 5.66E-09 5.57E-09 7.53E-09 6.53E-09 6.42E-09 6.33E-09Ps90%/90% (+KTL) Biased -2.29E-07 -2.36E-07 -2.40E-07 -2.39E-07 -2.47E-07 -2.39E-07 -2.35E-07Ps90%/90% (-KTL) Biased -2.63E-07 -2.67E-07 -2.70E-07 -2.80E-07 -2.83E-07 -2.74E-07 -2.70E-07Un-Biased StatisticsAverage Un-Biased -2.38E-07 -2.45E-07 -2.50E-07 -2.54E-07 -2.62E-07 -2.60E-07 -2.47E-07Std Dev Un-Biased 9.89E-09 9.11E-09 8.20E-09 7.83E-09 6.89E-09 8.04E-09 8.68E-09Ps90%/90% (+KTL) Un-Biased -2.11E-07 -2.20E-07 -2.27E-07 -2.33E-07 -2.44E-07 -2.38E-07 -2.24E-07Ps90%/90% (-KTL) Un-Biased -2.65E-07 -2.70E-07 -2.72E-07 -2.76E-07 -2.81E-07 -2.82E-07 -2.71E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 35: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

35

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

0 V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.14. Plot of Positive Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 36: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

36

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.14. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.41E-07 -2.45E-07 -2.49E-07 -2.53E-07 -2.58E-07 -2.49E-07 -2.47E-07879 -2.50E-07 -2.54E-07 -2.59E-07 -2.62E-07 -2.75E-07 -2.62E-07 -2.58E-07882 -2.56E-07 -2.63E-07 -2.67E-07 -2.71E-07 -2.76E-07 -2.68E-07 -2.63E-07883 -2.61E-07 -2.68E-07 -2.72E-07 -2.74E-07 -2.78E-07 -2.71E-07 -2.66E-07885 -2.41E-07 -2.47E-07 -2.52E-07 -2.59E-07 -2.62E-07 -2.53E-07 -2.48E-07886 -2.42E-07 -2.50E-07 -2.56E-07 -2.61E-07 -2.70E-07 -2.67E-07 -2.54E-07887 -2.59E-07 -2.67E-07 -2.73E-07 -2.78E-07 -2.87E-07 -2.83E-07 -2.70E-07891 -2.60E-07 -2.68E-07 -2.73E-07 -2.78E-07 -2.85E-07 -2.82E-07 -2.69E-07892 -2.55E-07 -2.61E-07 -2.65E-07 -2.70E-07 -2.77E-07 -2.75E-07 -2.63E-07895 -2.58E-07 -2.65E-07 -2.71E-07 -2.76E-07 -2.85E-07 -2.82E-07 -2.68E-07896 -2.64E-07 -2.83E-07 -2.83E-07 -2.83E-07 -2.82E-07 -2.82E-07 -2.83E-07

Biased StatisticsAverage Biased -2.50E-07 -2.56E-07 -2.60E-07 -2.64E-07 -2.70E-07 -2.61E-07 -2.57E-07Std Dev Biased 9.11E-09 9.87E-09 9.81E-09 8.62E-09 9.24E-09 9.17E-09 8.63E-09Ps90%/90% (+KTL) Biased -2.25E-07 -2.29E-07 -2.33E-07 -2.40E-07 -2.45E-07 -2.35E-07 -2.33E-07Ps90%/90% (-KTL) Biased -2.75E-07 -2.83E-07 -2.87E-07 -2.88E-07 -2.95E-07 -2.86E-07 -2.80E-07Un-Biased StatisticsAverage Un-Biased -2.55E-07 -2.62E-07 -2.67E-07 -2.73E-07 -2.81E-07 -2.78E-07 -2.65E-07Std Dev Un-Biased 7.57E-09 7.51E-09 7.21E-09 7.05E-09 6.88E-09 6.78E-09 6.81E-09Ps90%/90% (+KTL) Un-Biased -2.34E-07 -2.42E-07 -2.48E-07 -2.53E-07 -2.62E-07 -2.59E-07 -2.46E-07Ps90%/90% (-KTL) Un-Biased -2.76E-07 -2.83E-07 -2.87E-07 -2.92E-07 -3.00E-07 -2.97E-07 -2.84E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 37: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

37

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 0

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.15. Plot of Negative Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 38: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

38

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.15. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.37E-07 -2.41E-07 -2.46E-07 -2.50E-07 -2.55E-07 -2.46E-07 -2.44E-07879 -2.48E-07 -2.52E-07 -2.57E-07 -2.61E-07 -2.76E-07 -2.61E-07 -2.57E-07882 -2.55E-07 -2.63E-07 -2.67E-07 -2.70E-07 -2.76E-07 -2.67E-07 -2.63E-07883 -2.58E-07 -2.65E-07 -2.69E-07 -2.72E-07 -2.76E-07 -2.68E-07 -2.63E-07885 -2.41E-07 -2.48E-07 -2.53E-07 -2.62E-07 -2.63E-07 -2.55E-07 -2.50E-07886 -2.39E-07 -2.47E-07 -2.53E-07 -2.57E-07 -2.66E-07 -2.64E-07 -2.50E-07887 -2.56E-07 -2.64E-07 -2.70E-07 -2.75E-07 -2.84E-07 -2.81E-07 -2.66E-07891 -2.60E-07 -2.68E-07 -2.72E-07 -2.78E-07 -2.86E-07 -2.83E-07 -2.69E-07892 -2.57E-07 -2.62E-07 -2.67E-07 -2.71E-07 -2.78E-07 -2.76E-07 -2.64E-07895 -2.58E-07 -2.66E-07 -2.72E-07 -2.77E-07 -2.87E-07 -2.83E-07 -2.69E-07896 -2.59E-07 -2.78E-07 -2.77E-07 -2.77E-07 -2.76E-07 -2.76E-07 -2.77E-07

Biased StatisticsAverage Biased -2.48E-07 -2.54E-07 -2.58E-07 -2.63E-07 -2.69E-07 -2.60E-07 -2.55E-07Std Dev Biased 9.08E-09 1.00E-08 9.53E-09 8.68E-09 9.60E-09 9.26E-09 8.40E-09Ps90%/90% (+KTL) Biased -2.23E-07 -2.26E-07 -2.32E-07 -2.39E-07 -2.43E-07 -2.34E-07 -2.32E-07Ps90%/90% (-KTL) Biased -2.73E-07 -2.81E-07 -2.84E-07 -2.87E-07 -2.96E-07 -2.85E-07 -2.78E-07Un-Biased StatisticsAverage Un-Biased -2.54E-07 -2.62E-07 -2.67E-07 -2.72E-07 -2.80E-07 -2.77E-07 -2.64E-07Std Dev Un-Biased 8.55E-09 8.44E-09 8.21E-09 8.37E-09 8.70E-09 8.15E-09 8.13E-09Ps90%/90% (+KTL) Un-Biased -2.31E-07 -2.38E-07 -2.44E-07 -2.49E-07 -2.56E-07 -2.55E-07 -2.41E-07Ps90%/90% (-KTL) Un-Biased -2.78E-07 -2.85E-07 -2.89E-07 -2.95E-07 -3.04E-07 -3.00E-07 -2.86E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 39: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

39

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 0

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.16. Plot of Negative Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 40: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

40

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.16. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.43E-07 -2.47E-07 -2.52E-07 -2.59E-07 -2.67E-07 -2.53E-07 -2.51E-07879 -2.50E-07 -2.52E-07 -2.54E-07 -2.57E-07 -2.70E-07 -2.60E-07 -2.58E-07882 -2.38E-07 -2.45E-07 -2.49E-07 -2.53E-07 -2.58E-07 -2.50E-07 -2.46E-07883 -2.43E-07 -2.49E-07 -2.52E-07 -2.56E-07 -2.60E-07 -2.57E-07 -2.47E-07885 -2.50E-07 -2.57E-07 -2.62E-07 -2.70E-07 -2.69E-07 -2.61E-07 -2.57E-07886 -2.39E-07 -2.48E-07 -2.54E-07 -2.59E-07 -2.68E-07 -2.65E-07 -2.51E-07887 -2.48E-07 -2.54E-07 -2.58E-07 -2.61E-07 -2.67E-07 -2.66E-07 -2.56E-07891 -2.38E-07 -2.46E-07 -2.51E-07 -2.56E-07 -2.64E-07 -2.62E-07 -2.49E-07892 -2.45E-07 -2.53E-07 -2.57E-07 -2.62E-07 -2.70E-07 -2.68E-07 -2.54E-07895 -2.30E-07 -2.37E-07 -2.42E-07 -2.47E-07 -2.56E-07 -2.53E-07 -2.40E-07896 -2.39E-07 -2.56E-07 -2.56E-07 -2.56E-07 -2.55E-07 -2.55E-07 -2.56E-07

Biased StatisticsAverage Biased -2.45E-07 -2.50E-07 -2.54E-07 -2.59E-07 -2.65E-07 -2.56E-07 -2.52E-07Std Dev Biased 5.06E-09 4.60E-09 4.89E-09 6.35E-09 5.37E-09 4.96E-09 5.37E-09Ps90%/90% (+KTL) Biased -2.31E-07 -2.37E-07 -2.40E-07 -2.41E-07 -2.50E-07 -2.43E-07 -2.37E-07Ps90%/90% (-KTL) Biased -2.59E-07 -2.63E-07 -2.67E-07 -2.76E-07 -2.80E-07 -2.70E-07 -2.66E-07Un-Biased StatisticsAverage Un-Biased -2.40E-07 -2.47E-07 -2.52E-07 -2.57E-07 -2.65E-07 -2.63E-07 -2.50E-07Std Dev Un-Biased 7.09E-09 6.67E-09 6.22E-09 6.18E-09 5.45E-09 5.94E-09 6.21E-09Ps90%/90% (+KTL) Un-Biased -2.21E-07 -2.29E-07 -2.35E-07 -2.40E-07 -2.50E-07 -2.46E-07 -2.33E-07Ps90%/90% (-KTL) Un-Biased -2.60E-07 -2.66E-07 -2.69E-07 -2.74E-07 -2.80E-07 -2.79E-07 -2.67E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 41: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

41

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 0

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.17. Plot of Negative Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 42: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

42

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.17. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.46E-07 -2.50E-07 -2.55E-07 -2.60E-07 -2.65E-07 -2.56E-07 -2.54E-07879 -2.46E-07 -2.48E-07 -2.50E-07 -2.53E-07 -2.65E-07 -2.56E-07 -2.53E-07882 -2.41E-07 -2.48E-07 -2.52E-07 -2.55E-07 -2.61E-07 -2.53E-07 -2.49E-07883 -2.42E-07 -2.48E-07 -2.51E-07 -2.55E-07 -2.59E-07 -2.51E-07 -2.46E-07885 -2.56E-07 -2.62E-07 -2.67E-07 -2.76E-07 -2.77E-07 -2.68E-07 -2.64E-07886 -2.37E-07 -2.44E-07 -2.50E-07 -2.56E-07 -2.64E-07 -2.61E-07 -2.48E-07887 -2.49E-07 -2.54E-07 -2.57E-07 -2.61E-07 -2.66E-07 -2.66E-07 -2.56E-07891 -2.36E-07 -2.43E-07 -2.48E-07 -2.54E-07 -2.62E-07 -2.59E-07 -2.46E-07892 -2.39E-07 -2.45E-07 -2.50E-07 -2.56E-07 -2.63E-07 -2.61E-07 -2.47E-07895 -2.27E-07 -2.34E-07 -2.39E-07 -2.44E-07 -2.53E-07 -2.49E-07 -2.37E-07896 -2.39E-07 -2.56E-07 -2.56E-07 -2.55E-07 -2.54E-07 -2.55E-07 -2.55E-07

Biased StatisticsAverage Biased -2.46E-07 -2.51E-07 -2.55E-07 -2.60E-07 -2.65E-07 -2.57E-07 -2.53E-07Std Dev Biased 6.03E-09 6.33E-09 7.00E-09 9.45E-09 6.92E-09 6.70E-09 6.69E-09Ps90%/90% (+KTL) Biased -2.30E-07 -2.34E-07 -2.36E-07 -2.34E-07 -2.46E-07 -2.38E-07 -2.35E-07Ps90%/90% (-KTL) Biased -2.63E-07 -2.69E-07 -2.74E-07 -2.86E-07 -2.84E-07 -2.75E-07 -2.72E-07Un-Biased StatisticsAverage Un-Biased -2.37E-07 -2.44E-07 -2.49E-07 -2.54E-07 -2.62E-07 -2.59E-07 -2.47E-07Std Dev Un-Biased 7.89E-09 7.21E-09 6.73E-09 6.18E-09 5.36E-09 6.09E-09 6.76E-09Ps90%/90% (+KTL) Un-Biased -2.16E-07 -2.24E-07 -2.31E-07 -2.37E-07 -2.47E-07 -2.43E-07 -2.28E-07Ps90%/90% (-KTL) Un-Biased -2.59E-07 -2.64E-07 -2.67E-07 -2.71E-07 -2.76E-07 -2.76E-07 -2.66E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 43: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

43

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 0

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.18. Plot of Negative Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 44: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

44

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.18. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.36E-07 -2.41E-07 -2.46E-07 -2.50E-07 -2.55E-07 -2.46E-07 -2.44E-07879 -2.45E-07 -2.49E-07 -2.54E-07 -2.58E-07 -2.72E-07 -2.58E-07 -2.54E-07882 -2.57E-07 -2.64E-07 -2.68E-07 -2.72E-07 -2.77E-07 -2.68E-07 -2.64E-07883 -2.57E-07 -2.63E-07 -2.67E-07 -2.71E-07 -2.75E-07 -2.67E-07 -2.62E-07885 -2.40E-07 -2.47E-07 -2.52E-07 -2.61E-07 -2.62E-07 -2.54E-07 -2.49E-07886 -2.40E-07 -2.49E-07 -2.55E-07 -2.59E-07 -2.68E-07 -2.65E-07 -2.52E-07887 -2.56E-07 -2.64E-07 -2.70E-07 -2.75E-07 -2.83E-07 -2.80E-07 -2.66E-07891 -2.56E-07 -2.63E-07 -2.68E-07 -2.73E-07 -2.80E-07 -2.78E-07 -2.65E-07892 -2.56E-07 -2.62E-07 -2.66E-07 -2.71E-07 -2.78E-07 -2.76E-07 -2.63E-07895 -2.53E-07 -2.61E-07 -2.66E-07 -2.71E-07 -2.80E-07 -2.76E-07 -2.63E-07896 -2.67E-07 -2.86E-07 -2.86E-07 -2.86E-07 -2.85E-07 -2.85E-07 -2.86E-07

Biased StatisticsAverage Biased -2.47E-07 -2.53E-07 -2.57E-07 -2.62E-07 -2.68E-07 -2.59E-07 -2.55E-07Std Dev Biased 9.53E-09 1.04E-08 9.78E-09 9.30E-09 9.45E-09 9.31E-09 8.69E-09Ps90%/90% (+KTL) Biased -2.21E-07 -2.24E-07 -2.30E-07 -2.37E-07 -2.42E-07 -2.33E-07 -2.31E-07Ps90%/90% (-KTL) Biased -2.73E-07 -2.81E-07 -2.84E-07 -2.88E-07 -2.94E-07 -2.84E-07 -2.78E-07Un-Biased StatisticsAverage Un-Biased -2.52E-07 -2.60E-07 -2.65E-07 -2.70E-07 -2.78E-07 -2.75E-07 -2.62E-07Std Dev Un-Biased 6.79E-09 6.28E-09 5.86E-09 6.01E-09 5.74E-09 5.67E-09 5.84E-09Ps90%/90% (+KTL) Un-Biased -2.34E-07 -2.42E-07 -2.49E-07 -2.53E-07 -2.62E-07 -2.59E-07 -2.46E-07Ps90%/90% (-KTL) Un-Biased -2.71E-07 -2.77E-07 -2.81E-07 -2.86E-07 -2.94E-07 -2.91E-07 -2.78E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 45: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

45

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

15 V

#1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.19. Plot of Input Offset Voltage @ +/- 15V, VCM= 15 V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 46: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

46

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.19. Raw data for Input Offset Voltage @ +/- 15V, VCM= 15 V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.61E-05 5.63E-05 6.59E-05 7.36E-05 7.32E-05 6.82E-05 6.14E-05879 1.20E-04 9.32E-05 1.07E-04 9.76E-05 9.80E-05 9.28E-05 1.00E-04882 3.10E-04 3.03E-04 3.07E-04 3.10E-04 3.11E-04 3.07E-04 3.15E-04883 2.01E-04 1.86E-04 1.89E-04 2.07E-04 1.96E-04 1.86E-04 1.98E-04885 2.88E-05 1.13E-05 1.91E-05 2.17E-05 1.96E-05 1.25E-05 4.98E-06886 3.16E-05 1.42E-05 9.58E-06 5.84E-06 1.13E-06 -5.70E-07 -3.71E-06887 3.90E-04 3.77E-04 3.76E-04 3.77E-04 3.68E-04 3.66E-04 3.63E-04891 2.62E-04 2.44E-04 2.41E-04 2.38E-04 2.36E-04 2.33E-04 2.21E-04892 -1.07E-04 -1.17E-04 -1.21E-04 -1.25E-04 -1.29E-04 -1.29E-04 -1.27E-04895 7.58E-05 5.91E-05 5.25E-05 4.86E-05 3.80E-05 3.82E-05 5.40E-05896 -3.87E-05 -5.08E-05 -5.06E-05 -5.06E-05 -5.02E-05 -5.03E-05 -4.99E-05

Biased StatisticsAverage Biased 1.47E-04 1.30E-04 1.38E-04 1.42E-04 1.40E-04 1.33E-04 1.36E-04Std Dev Biased 1.11E-04 1.16E-04 1.14E-04 1.16E-04 1.15E-04 1.16E-04 1.22E-04Ps90%/90% (+KTL) Biased 4.51E-04 4.49E-04 4.49E-04 4.59E-04 4.55E-04 4.51E-04 4.72E-04Ps90%/90% (-KTL) Biased -1.57E-04 -1.89E-04 -1.74E-04 -1.75E-04 -1.76E-04 -1.84E-04 -2.00E-04Un-Biased StatisticsAverage Un-Biased 1.30E-04 1.15E-04 1.12E-04 1.09E-04 1.03E-04 1.01E-04 1.01E-04Std Dev Un-Biased 1.96E-04 1.95E-04 1.97E-04 1.98E-04 1.98E-04 1.97E-04 1.93E-04Ps90%/90% (+KTL) Un-Biased 6.68E-04 6.51E-04 6.52E-04 6.53E-04 6.45E-04 6.41E-04 6.30E-04Ps90%/90% (-KTL) Un-Biased -4.07E-04 -4.20E-04 -4.28E-04 -4.35E-04 -4.39E-04 -4.39E-04 -4.27E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 47: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

47

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

15 V

#2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.20. Plot of Input Offset Voltage @ +/- 15V, VCM= 15 V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 48: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

48

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.20. Raw data for Input Offset Voltage @ +/- 15V, VCM= 15 V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.43E-04 1.27E-04 1.34E-04 1.65E-04 1.96E-04 1.62E-04 1.50E-04879 6.76E-05 7.26E-05 9.32E-05 8.65E-05 8.85E-05 8.66E-05 9.32E-05882 2.46E-04 2.36E-04 2.38E-04 2.43E-04 2.46E-04 2.41E-04 2.37E-04883 1.19E-04 1.06E-04 1.18E-04 1.39E-04 1.35E-04 1.52E-04 1.30E-04885 2.33E-04 2.36E-04 2.68E-04 2.55E-04 2.53E-04 2.37E-04 2.43E-04886 3.17E-04 2.98E-04 2.97E-04 2.96E-04 2.96E-04 2.92E-04 2.73E-04887 2.25E-04 2.30E-04 2.32E-04 2.31E-04 2.31E-04 2.27E-04 2.05E-04891 3.25E-04 3.25E-04 3.27E-04 3.27E-04 3.27E-04 3.19E-04 3.17E-04892 3.60E-05 2.90E-05 2.90E-05 2.87E-05 2.63E-05 2.44E-05 1.20E-05895 6.64E-05 5.45E-05 5.11E-05 5.08E-05 4.94E-05 4.45E-05 3.87E-05896 -6.82E-05 -7.78E-05 -7.81E-05 -7.80E-05 -7.86E-05 -7.90E-05 -7.82E-05

Biased StatisticsAverage Biased 1.62E-04 1.55E-04 1.70E-04 1.78E-04 1.84E-04 1.76E-04 1.70E-04Std Dev Biased 7.63E-05 7.58E-05 7.76E-05 7.11E-05 7.13E-05 6.47E-05 6.65E-05Ps90%/90% (+KTL) Biased 3.71E-04 3.63E-04 3.83E-04 3.72E-04 3.79E-04 3.53E-04 3.53E-04Ps90%/90% (-KTL) Biased -4.74E-05 -5.24E-05 -4.26E-05 -1.72E-05 -1.19E-05 -1.69E-06 -1.19E-05Un-Biased StatisticsAverage Un-Biased 1.94E-04 1.87E-04 1.87E-04 1.87E-04 1.86E-04 1.81E-04 1.69E-04Std Dev Un-Biased 1.37E-04 1.38E-04 1.39E-04 1.39E-04 1.40E-04 1.38E-04 1.37E-04Ps90%/90% (+KTL) Un-Biased 5.69E-04 5.65E-04 5.68E-04 5.67E-04 5.69E-04 5.61E-04 5.46E-04Ps90%/90% (-KTL) Un-Biased -1.81E-04 -1.90E-04 -1.94E-04 -1.94E-04 -1.97E-04 -1.98E-04 -2.08E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 49: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

49

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

15 V

#3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.21. Plot of Input Offset Voltage @ +/- 15V, VCM= 15 V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 50: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

50

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.21. Raw data for Input Offset Voltage @ +/- 15V, VCM= 15 V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -1.48E-04 -1.70E-04 -1.63E-04 -1.55E-04 -1.53E-04 -1.57E-04 -1.58E-04879 4.30E-04 4.01E-04 4.27E-04 4.16E-04 4.23E-04 4.17E-04 4.31E-04882 4.50E-05 2.48E-05 2.92E-05 2.78E-05 2.86E-05 2.44E-05 1.96E-05883 2.92E-04 2.68E-04 2.72E-04 2.92E-04 2.75E-04 2.76E-04 2.73E-04885 5.66E-05 3.31E-05 3.75E-05 4.55E-05 2.86E-05 2.60E-05 4.13E-05886 2.52E-05 1.01E-05 9.58E-06 6.44E-06 -3.20E-07 5.20E-07 1.24E-06887 -1.87E-04 -1.96E-04 -1.90E-04 -1.94E-04 -1.97E-04 -2.00E-04 -2.03E-04891 2.81E-04 2.68E-04 2.69E-04 2.67E-04 2.66E-04 2.59E-04 2.53E-04892 3.46E-04 3.35E-04 3.35E-04 3.35E-04 3.35E-04 3.32E-04 3.28E-04895 3.62E-05 1.88E-05 1.61E-05 1.43E-05 1.01E-05 9.46E-06 6.92E-06896 2.16E-04 1.71E-04 1.71E-04 1.74E-04 1.76E-04 1.76E-04 1.74E-04

Biased StatisticsAverage Biased 1.35E-04 1.11E-04 1.21E-04 1.25E-04 1.20E-04 1.17E-04 1.22E-04Std Dev Biased 2.27E-04 2.24E-04 2.31E-04 2.27E-04 2.27E-04 2.28E-04 2.31E-04Ps90%/90% (+KTL) Biased 7.57E-04 7.26E-04 7.53E-04 7.49E-04 7.44E-04 7.42E-04 7.55E-04Ps90%/90% (-KTL) Biased -4.87E-04 -5.04E-04 -5.12E-04 -4.98E-04 -5.03E-04 -5.07E-04 -5.12E-04Un-Biased StatisticsAverage Un-Biased 1.00E-04 8.71E-05 8.78E-05 8.59E-05 8.28E-05 8.02E-05 7.71E-05Std Dev Un-Biased 2.15E-04 2.15E-04 2.13E-04 2.15E-04 2.16E-04 2.16E-04 2.14E-04Ps90%/90% (+KTL) Un-Biased 6.91E-04 6.76E-04 6.73E-04 6.75E-04 6.76E-04 6.71E-04 6.64E-04Ps90%/90% (-KTL) Un-Biased -4.90E-04 -5.01E-04 -4.98E-04 -5.03E-04 -5.11E-04 -5.11E-04 -5.10E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 51: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

51

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

15 V

#4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.22. Plot of Input Offset Voltage @ +/- 15V, VCM= 15 V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 52: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

52

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.22. Raw data for Input Offset Voltage @ +/- 15V, VCM= 15 V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.97E-04 1.80E-04 1.91E-04 1.96E-04 2.06E-04 2.01E-04 1.90E-04879 5.24E-06 -1.74E-05 1.97E-06 -9.74E-06 -6.00E-06 -5.88E-06 -1.25E-05882 3.46E-04 3.35E-04 3.47E-04 3.52E-04 3.63E-04 3.55E-04 3.68E-04883 -1.36E-05 -2.52E-05 -1.72E-05 7.65E-06 -7.57E-06 -1.16E-05 -1.54E-05885 6.37E-05 3.85E-05 4.43E-05 5.63E-05 4.43E-05 3.95E-05 3.18E-05886 1.75E-04 1.57E-04 1.52E-04 1.50E-04 1.51E-04 1.44E-04 1.38E-04887 9.82E-05 8.51E-05 8.27E-05 8.23E-05 7.57E-05 7.32E-05 8.37E-05891 2.07E-04 1.93E-04 1.95E-04 1.99E-04 2.00E-04 1.95E-04 1.80E-04892 2.70E-05 3.16E-05 3.30E-05 2.85E-05 3.41E-05 3.49E-05 1.80E-05895 2.93E-04 2.80E-04 2.73E-04 2.72E-04 2.62E-04 2.59E-04 2.55E-04896 1.52E-04 1.32E-04 1.31E-04 1.29E-04 1.30E-04 1.30E-04 1.32E-04

Biased StatisticsAverage Biased 1.20E-04 1.02E-04 1.13E-04 1.20E-04 1.20E-04 1.16E-04 1.12E-04Std Dev Biased 1.51E-04 1.54E-04 1.54E-04 1.53E-04 1.62E-04 1.59E-04 1.66E-04Ps90%/90% (+KTL) Biased 5.34E-04 5.24E-04 5.35E-04 5.39E-04 5.63E-04 5.52E-04 5.67E-04Ps90%/90% (-KTL) Biased -2.95E-04 -3.20E-04 -3.09E-04 -2.98E-04 -3.23E-04 -3.21E-04 -3.42E-04Un-Biased StatisticsAverage Un-Biased 1.60E-04 1.49E-04 1.47E-04 1.46E-04 1.45E-04 1.41E-04 1.35E-04Std Dev Un-Biased 1.02E-04 9.62E-05 9.42E-05 9.54E-05 9.21E-05 9.03E-05 9.03E-05Ps90%/90% (+KTL) Un-Biased 4.40E-04 4.13E-04 4.05E-04 4.08E-04 3.97E-04 3.89E-04 3.82E-04Ps90%/90% (-KTL) Un-Biased -1.20E-04 -1.14E-04 -1.11E-04 -1.15E-04 -1.08E-04 -1.06E-04 -1.13E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 53: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

53

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

15 V

#1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.23. Plot of Input Offset Current @ +/- 15V, VCM= 15 V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 54: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

54

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.23. Raw data for Input Offset Current @ +/- 15V, VCM= 15 V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.16E-09 2.75E-10 1.39E-09 1.98E-09 -3.61E-10 5.55E-10 1.53E-08879 4.44E-09 5.12E-09 4.40E-09 4.52E-09 1.23E-08 9.95E-09 2.40E-08882 2.94E-09 5.30E-09 3.96E-09 3.78E-09 5.69E-09 2.91E-09 1.73E-08883 -2.19E-09 -2.72E-09 -3.37E-09 -1.84E-09 -2.45E-09 -2.65E-09 1.32E-08885 8.53E-10 2.99E-09 -2.02E-10 7.55E-09 4.46E-09 1.12E-09 2.10E-08886 1.35E-09 1.16E-09 9.67E-10 -2.82E-10 1.10E-11 -1.20E-10 9.46E-10887 1.42E-08 1.36E-08 1.40E-08 1.48E-08 1.30E-08 1.41E-08 1.27E-08891 1.81E-09 1.55E-09 2.39E-09 2.61E-09 3.21E-09 3.91E-09 1.41E-09892 1.45E-09 3.99E-10 5.82E-10 1.20E-09 2.95E-09 1.76E-09 2.94E-10895 7.49E-09 8.90E-09 6.56E-09 6.37E-09 5.83E-09 7.80E-09 6.09E-09896 1.32E-10 1.63E-10 -5.00E-12 3.70E-11 7.40E-11 6.60E-11 9.30E-11

Biased StatisticsAverage Biased 1.44E-09 2.19E-09 1.24E-09 3.20E-09 3.92E-09 2.38E-09 1.82E-08Std Dev Biased 2.49E-09 3.41E-09 3.19E-09 3.46E-09 5.74E-09 4.68E-09 4.34E-09Ps90%/90% (+KTL) Biased 8.28E-09 1.16E-08 9.99E-09 1.27E-08 1.97E-08 1.52E-08 3.01E-08Ps90%/90% (-KTL) Biased -5.39E-09 -7.17E-09 -7.52E-09 -6.29E-09 -1.18E-08 -1.05E-08 6.27E-09Un-Biased StatisticsAverage Un-Biased 5.26E-09 5.12E-09 4.89E-09 4.94E-09 5.00E-09 5.48E-09 4.29E-09Std Dev Un-Biased 5.62E-09 5.84E-09 5.60E-09 6.04E-09 4.93E-09 5.63E-09 5.24E-09Ps90%/90% (+KTL) Un-Biased 2.07E-08 2.11E-08 2.02E-08 2.15E-08 1.85E-08 2.09E-08 1.87E-08Ps90%/90% (-KTL) Un-Biased -1.01E-08 -1.09E-08 -1.05E-08 -1.16E-08 -8.52E-09 -9.95E-09 -1.01E-08Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 55: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

55

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

15 V

#2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.24. Plot of Input Offset Current @ +/- 15V, VCM= 15 V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 56: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

56

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.24. Raw data for Input Offset Current @ +/- 15V, VCM= 15 V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.64E-09 -4.03E-09 -3.44E-09 -8.20E-10 2.06E-09 4.05E-09 2.29E-08879 -8.45E-10 1.85E-09 4.31E-09 5.18E-09 1.36E-08 9.01E-09 2.37E-08882 -9.38E-10 6.90E-10 1.18E-09 5.39E-10 -8.94E-10 4.71E-10 1.63E-08883 1.66E-09 1.93E-09 2.04E-09 3.92E-09 4.88E-09 -4.03E-10 1.85E-08885 2.53E-09 4.34E-09 7.75E-09 1.14E-08 7.48E-09 5.98E-09 2.22E-08886 -1.02E-08 -9.39E-09 -9.26E-09 -9.09E-09 -8.04E-09 -8.95E-09 -1.02E-08887 1.48E-08 1.53E-08 1.50E-08 1.44E-08 1.29E-08 1.44E-08 1.40E-08891 -1.30E-09 2.99E-10 3.06E-10 1.07E-09 1.87E-09 -4.26E-10 -7.95E-10892 -4.61E-09 -4.47E-09 -4.37E-09 -2.26E-09 -3.60E-09 -2.86E-09 -4.99E-09895 4.40E-09 3.78E-09 3.18E-09 3.75E-09 3.36E-09 2.04E-09 2.85E-09896 -6.33E-09 -8.84E-09 -9.13E-09 -8.72E-09 -8.84E-09 -8.91E-09 -8.63E-09

Biased StatisticsAverage Biased -4.74E-11 9.56E-10 2.37E-09 4.04E-09 5.43E-09 3.82E-09 2.07E-08Std Dev Biased 2.11E-09 3.09E-09 4.12E-09 4.78E-09 5.55E-09 3.89E-09 3.18E-09Ps90%/90% (+KTL) Biased 5.73E-09 9.43E-09 1.37E-08 1.71E-08 2.06E-08 1.45E-08 2.95E-08Ps90%/90% (-KTL) Biased -5.82E-09 -7.52E-09 -8.94E-09 -9.06E-09 -9.78E-09 -6.86E-09 1.20E-08Un-Biased StatisticsAverage Un-Biased 6.14E-10 1.10E-09 9.68E-10 1.58E-09 1.29E-09 8.39E-10 1.75E-10Std Dev Un-Biased 9.55E-09 9.36E-09 9.15E-09 8.64E-09 7.90E-09 8.61E-09 9.11E-09Ps90%/90% (+KTL) Un-Biased 2.68E-08 2.68E-08 2.61E-08 2.53E-08 2.29E-08 2.44E-08 2.51E-08Ps90%/90% (-KTL) Un-Biased -2.56E-08 -2.46E-08 -2.41E-08 -2.21E-08 -2.04E-08 -2.28E-08 -2.48E-08Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 57: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

57

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

15 V

#3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.25. Plot of Input Offset Current @ +/- 15V, VCM= 15 V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 58: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

58

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.25. Raw data for Input Offset Current @ +/- 15V, VCM= 15 V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -6.92E-09 -7.64E-09 -8.02E-09 -7.93E-09 -7.49E-09 -6.77E-09 6.88E-09879 -7.24E-09 -7.18E-09 -6.50E-09 -4.68E-09 4.30E-09 2.84E-09 1.69E-08882 -9.37E-09 -8.96E-09 -9.17E-09 -9.48E-09 -1.29E-08 -1.18E-08 4.20E-09883 4.39E-09 5.60E-09 5.62E-09 7.20E-09 7.89E-09 6.43E-09 2.08E-08885 -5.76E-09 -6.79E-09 -6.64E-09 -1.28E-09 -2.84E-09 -4.21E-09 1.12E-08886 -2.33E-09 -3.37E-09 -1.89E-09 -1.70E-09 -1.58E-09 -3.32E-09 -1.91E-09887 -6.43E-09 -6.85E-09 -6.43E-09 -4.85E-09 -4.89E-09 -5.27E-09 -7.06E-09891 1.24E-08 1.19E-08 1.20E-08 1.31E-08 1.32E-08 1.20E-08 1.10E-08892 -5.42E-09 -5.08E-09 -6.84E-09 -4.33E-09 -1.94E-09 -3.55E-09 -5.40E-09895 -1.31E-08 -1.47E-08 -1.47E-08 -1.48E-08 -1.44E-08 -1.45E-08 -1.43E-08896 -4.52E-09 -5.42E-09 -5.46E-09 -5.28E-09 -5.24E-09 -5.36E-09 -5.33E-09

Biased StatisticsAverage Biased -4.98E-09 -4.99E-09 -4.94E-09 -3.23E-09 -2.20E-09 -2.70E-09 1.20E-08Std Dev Biased 5.40E-09 5.98E-09 6.00E-09 6.63E-09 8.47E-09 7.34E-09 6.87E-09Ps90%/90% (+KTL) Biased 9.82E-09 1.14E-08 1.15E-08 1.49E-08 2.10E-08 1.74E-08 3.08E-08Ps90%/90% (-KTL) Biased -1.98E-08 -2.14E-08 -2.14E-08 -2.14E-08 -2.54E-08 -2.28E-08 -6.85E-09Un-Biased StatisticsAverage Un-Biased -2.96E-09 -3.62E-09 -3.58E-09 -2.51E-09 -1.93E-09 -2.93E-09 -3.53E-09Std Dev Un-Biased 9.46E-09 9.67E-09 9.86E-09 1.00E-08 9.94E-09 9.51E-09 9.33E-09Ps90%/90% (+KTL) Un-Biased 2.30E-08 2.29E-08 2.35E-08 2.50E-08 2.53E-08 2.31E-08 2.20E-08Ps90%/90% (-KTL) Un-Biased -2.89E-08 -3.01E-08 -3.06E-08 -3.00E-08 -2.92E-08 -2.90E-08 -2.91E-08Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 59: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

59

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

15 V

#4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.26. Plot of Input Offset Current @ +/- 15V, VCM= 15 V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 60: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

60

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.26. Raw data for Input Offset Current @ +/- 15V, VCM= 15 V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= 15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -6.79E-09 -5.19E-09 -4.47E-09 -3.98E-09 -3.21E-09 -4.28E-09 9.00E-09879 -1.30E-08 -1.25E-08 -1.06E-08 -1.10E-08 -5.20E-09 -5.18E-09 7.93E-09882 1.31E-08 1.37E-08 1.49E-08 1.39E-08 1.42E-08 1.53E-08 2.74E-08883 -3.40E-10 -2.23E-09 -3.20E-09 -1.99E-09 -2.55E-09 -3.98E-09 1.50E-08885 1.21E-09 1.16E-09 1.81E-09 7.25E-09 3.30E-09 4.25E-09 1.88E-08886 -4.75E-09 -4.58E-09 -4.57E-09 -4.54E-09 -3.23E-09 -4.36E-09 -5.12E-09887 1.40E-08 1.34E-08 1.20E-08 1.24E-08 1.16E-08 1.09E-08 1.36E-08891 1.24E-08 1.20E-08 1.21E-08 1.28E-08 1.40E-08 1.31E-08 1.24E-08892 -1.14E-08 -1.04E-08 -9.23E-09 -8.18E-09 -6.68E-09 -6.83E-09 -1.01E-08895 8.03E-10 4.50E-10 6.46E-10 1.10E-09 7.42E-10 -4.66E-10 -7.63E-10896 4.67E-10 -6.18E-10 -5.99E-10 -7.32E-10 -5.46E-10 -7.53E-10 -7.21E-10

Biased StatisticsAverage Biased -1.15E-09 -1.01E-09 -3.19E-10 8.35E-10 1.31E-09 1.21E-09 1.56E-08Std Dev Biased 9.77E-09 9.65E-09 9.57E-09 9.76E-09 7.87E-09 8.72E-09 7.93E-09Ps90%/90% (+KTL) Biased 2.56E-08 2.55E-08 2.59E-08 2.76E-08 2.29E-08 2.51E-08 3.73E-08Ps90%/90% (-KTL) Biased -2.79E-08 -2.75E-08 -2.66E-08 -2.59E-08 -2.03E-08 -2.27E-08 -6.12E-09Un-Biased StatisticsAverage Un-Biased 2.22E-09 2.19E-09 2.18E-09 2.73E-09 3.29E-09 2.48E-09 2.01E-09Std Dev Un-Biased 1.09E-08 1.04E-08 9.65E-09 9.63E-09 9.12E-09 9.04E-09 1.06E-08Ps90%/90% (+KTL) Un-Biased 3.22E-08 3.06E-08 2.86E-08 2.91E-08 2.83E-08 2.73E-08 3.11E-08Ps90%/90% (-KTL) Un-Biased -2.78E-08 -2.63E-08 -2.43E-08 -2.37E-08 -2.17E-08 -2.23E-08 -2.71E-08Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 61: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

61

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

15 V

#1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.27. Plot of Positive Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 62: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

62

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.27. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.45E-07 3.76E-07 4.10E-07 4.36E-07 4.79E-07 4.36E-07 4.14E-07879 3.80E-07 4.12E-07 4.39E-07 4.66E-07 5.23E-07 4.77E-07 4.56E-07882 3.89E-07 4.27E-07 4.57E-07 4.84E-07 5.26E-07 4.85E-07 4.58E-07883 4.24E-07 4.61E-07 4.90E-07 5.16E-07 5.64E-07 5.18E-07 4.89E-07885 3.75E-07 4.04E-07 4.43E-07 4.76E-07 5.16E-07 4.71E-07 4.43E-07886 3.69E-07 4.01E-07 4.30E-07 4.56E-07 5.00E-07 4.83E-07 4.28E-07887 4.04E-07 4.35E-07 4.67E-07 4.95E-07 5.40E-07 5.20E-07 4.60E-07891 4.04E-07 4.33E-07 4.63E-07 4.90E-07 5.35E-07 5.17E-07 4.57E-07892 4.35E-07 4.67E-07 4.98E-07 5.30E-07 5.81E-07 5.58E-07 4.93E-07895 4.15E-07 4.47E-07 4.79E-07 5.08E-07 5.57E-07 5.38E-07 4.72E-07896 3.96E-07 4.08E-07 4.08E-07 4.09E-07 4.07E-07 4.08E-07 4.08E-07

Biased StatisticsAverage Biased 3.83E-07 4.16E-07 4.48E-07 4.76E-07 5.22E-07 4.77E-07 4.52E-07Std Dev Biased 2.85E-08 3.13E-08 2.93E-08 2.88E-08 3.03E-08 2.92E-08 2.71E-08Ps90%/90% (+KTL) Biased 4.61E-07 5.02E-07 5.28E-07 5.55E-07 6.05E-07 5.57E-07 5.26E-07Ps90%/90% (-KTL) Biased 3.05E-07 3.30E-07 3.67E-07 3.97E-07 4.39E-07 3.97E-07 3.78E-07Un-Biased StatisticsAverage Un-Biased 4.06E-07 4.37E-07 4.67E-07 4.96E-07 5.42E-07 5.23E-07 4.62E-07Std Dev Un-Biased 2.41E-08 2.41E-08 2.48E-08 2.70E-08 2.98E-08 2.77E-08 2.37E-08Ps90%/90% (+KTL) Un-Biased 4.72E-07 5.03E-07 5.35E-07 5.70E-07 6.24E-07 5.99E-07 5.27E-07Ps90%/90% (-KTL) Un-Biased 3.40E-07 3.71E-07 3.99E-07 4.22E-07 4.61E-07 4.47E-07 3.97E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 63: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

63

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

15 V

#2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.28. Plot of Positive Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 64: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

64

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.28. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.69E-07 4.05E-07 4.39E-07 4.67E-07 5.13E-07 4.72E-07 4.54E-07879 4.25E-07 4.54E-07 4.79E-07 5.07E-07 5.74E-07 5.28E-07 5.09E-07882 3.62E-07 3.93E-07 4.23E-07 4.47E-07 4.88E-07 4.49E-07 4.30E-07883 4.19E-07 4.55E-07 4.87E-07 5.13E-07 5.60E-07 5.12E-07 4.87E-07885 4.13E-07 4.49E-07 4.86E-07 5.19E-07 5.55E-07 5.14E-07 4.88E-07886 3.69E-07 4.01E-07 4.29E-07 4.54E-07 4.99E-07 4.82E-07 4.27E-07887 4.39E-07 4.67E-07 4.97E-07 5.25E-07 5.70E-07 5.56E-07 4.96E-07891 3.90E-07 4.25E-07 4.54E-07 4.80E-07 5.23E-07 5.06E-07 4.52E-07892 4.14E-07 4.45E-07 4.77E-07 5.06E-07 5.54E-07 5.32E-07 4.70E-07895 3.63E-07 3.94E-07 4.24E-07 4.49E-07 4.97E-07 4.78E-07 4.21E-07896 3.73E-07 3.87E-07 3.85E-07 3.85E-07 3.85E-07 3.84E-07 3.87E-07

Biased StatisticsAverage Biased 3.98E-07 4.31E-07 4.63E-07 4.91E-07 5.38E-07 4.95E-07 4.74E-07Std Dev Biased 2.97E-08 2.99E-08 2.97E-08 3.19E-08 3.61E-08 3.30E-08 3.13E-08Ps90%/90% (+KTL) Biased 4.79E-07 5.13E-07 5.44E-07 5.78E-07 6.37E-07 5.86E-07 5.60E-07Ps90%/90% (-KTL) Biased 3.16E-07 3.49E-07 3.81E-07 4.03E-07 4.39E-07 4.04E-07 3.88E-07Un-Biased StatisticsAverage Un-Biased 3.95E-07 4.26E-07 4.56E-07 4.83E-07 5.29E-07 5.11E-07 4.53E-07Std Dev Un-Biased 3.15E-08 3.06E-08 3.11E-08 3.27E-08 3.28E-08 3.31E-08 3.11E-08Ps90%/90% (+KTL) Un-Biased 4.81E-07 5.10E-07 5.42E-07 5.73E-07 6.19E-07 6.02E-07 5.38E-07Ps90%/90% (-KTL) Un-Biased 3.09E-07 3.42E-07 3.71E-07 3.93E-07 4.39E-07 4.20E-07 3.68E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 65: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

65

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

15 V

#3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.29. Plot of Positive Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 66: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

66

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.29. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.57E-07 3.87E-07 4.17E-07 4.43E-07 4.86E-07 4.45E-07 4.22E-07879 4.21E-07 4.46E-07 4.97E-07 5.05E-07 5.69E-07 5.29E-07 5.07E-07882 3.53E-07 4.06E-07 4.19E-07 4.42E-07 4.80E-07 4.44E-07 4.22E-07883 4.05E-07 4.43E-07 4.72E-07 5.30E-07 5.49E-07 5.04E-07 4.75E-07885 4.21E-07 4.52E-07 4.84E-07 5.27E-07 5.61E-07 5.16E-07 4.89E-07886 3.69E-07 4.00E-07 4.29E-07 4.56E-07 5.00E-07 4.83E-07 4.30E-07887 4.14E-07 4.44E-07 4.72E-07 5.01E-07 5.48E-07 5.31E-07 4.71E-07891 4.01E-07 4.36E-07 4.67E-07 4.93E-07 5.36E-07 5.19E-07 4.65E-07892 4.18E-07 4.52E-07 4.81E-07 5.11E-07 5.58E-07 5.38E-07 4.76E-07895 3.61E-07 3.92E-07 4.23E-07 4.50E-07 4.97E-07 4.77E-07 4.19E-07896 3.65E-07 3.74E-07 3.74E-07 3.74E-07 3.73E-07 3.73E-07 3.75E-07

Biased StatisticsAverage Biased 3.92E-07 4.27E-07 4.58E-07 4.89E-07 5.29E-07 4.88E-07 4.63E-07Std Dev Biased 3.38E-08 2.89E-08 3.75E-08 4.39E-08 4.26E-08 4.01E-08 3.89E-08Ps90%/90% (+KTL) Biased 4.84E-07 5.06E-07 5.61E-07 6.10E-07 6.46E-07 5.98E-07 5.70E-07Ps90%/90% (-KTL) Biased 2.99E-07 3.48E-07 3.55E-07 3.69E-07 4.12E-07 3.78E-07 3.56E-07Un-Biased StatisticsAverage Un-Biased 3.92E-07 4.25E-07 4.54E-07 4.82E-07 5.28E-07 5.10E-07 4.52E-07Std Dev Un-Biased 2.61E-08 2.71E-08 2.65E-08 2.74E-08 2.78E-08 2.78E-08 2.57E-08Ps90%/90% (+KTL) Un-Biased 4.64E-07 4.99E-07 5.27E-07 5.58E-07 6.04E-07 5.86E-07 5.23E-07Ps90%/90% (-KTL) Un-Biased 3.21E-07 3.50E-07 3.82E-07 4.07E-07 4.52E-07 4.34E-07 3.82E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 67: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

67

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

15 V

#4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.30. Plot of Positive Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 68: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

68

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.30. Raw data for Positive Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.51E-07 3.85E-07 4.15E-07 4.42E-07 4.86E-07 4.45E-07 4.22E-07879 3.72E-07 4.06E-07 4.59E-07 4.66E-07 5.22E-07 4.77E-07 4.54E-07882 4.05E-07 4.55E-07 4.72E-07 4.97E-07 5.40E-07 5.00E-07 4.73E-07883 4.31E-07 4.66E-07 4.96E-07 5.52E-07 5.70E-07 5.27E-07 5.00E-07885 3.60E-07 3.92E-07 4.25E-07 4.63E-07 4.98E-07 4.57E-07 4.30E-07886 3.63E-07 3.91E-07 4.21E-07 4.45E-07 4.87E-07 4.73E-07 4.22E-07887 4.10E-07 4.40E-07 4.71E-07 4.99E-07 5.41E-07 5.25E-07 4.66E-07891 4.21E-07 4.48E-07 4.77E-07 5.06E-07 5.49E-07 5.32E-07 4.73E-07892 4.34E-07 4.61E-07 4.91E-07 5.23E-07 5.74E-07 5.56E-07 4.90E-07895 4.12E-07 4.41E-07 4.72E-07 5.03E-07 5.53E-07 5.32E-07 4.68E-07896 3.96E-07 4.08E-07 4.07E-07 4.09E-07 4.06E-07 4.11E-07 4.12E-07

Biased StatisticsAverage Biased 3.84E-07 4.21E-07 4.53E-07 4.84E-07 5.23E-07 4.81E-07 4.56E-07Std Dev Biased 3.34E-08 3.72E-08 3.34E-08 4.28E-08 3.37E-08 3.31E-08 3.21E-08Ps90%/90% (+KTL) Biased 4.75E-07 5.23E-07 5.45E-07 6.02E-07 6.16E-07 5.72E-07 5.44E-07Ps90%/90% (-KTL) Biased 2.92E-07 3.19E-07 3.62E-07 3.67E-07 4.31E-07 3.90E-07 3.68E-07Un-Biased StatisticsAverage Un-Biased 4.08E-07 4.36E-07 4.66E-07 4.95E-07 5.41E-07 5.23E-07 4.64E-07Std Dev Un-Biased 2.68E-08 2.66E-08 2.66E-08 2.95E-08 3.24E-08 3.06E-08 2.53E-08Ps90%/90% (+KTL) Un-Biased 4.81E-07 5.09E-07 5.39E-07 5.76E-07 6.30E-07 6.07E-07 5.33E-07Ps90%/90% (-KTL) Un-Biased 3.34E-07 3.63E-07 3.93E-07 4.14E-07 4.52E-07 4.40E-07 3.94E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 69: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

69

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 15

V #

1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.31. Plot of Negative Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 70: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

70

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.31. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.41E-07 3.73E-07 4.06E-07 4.31E-07 4.76E-07 4.34E-07 3.97E-07879 3.71E-07 4.02E-07 4.29E-07 4.58E-07 5.07E-07 4.65E-07 4.29E-07882 3.85E-07 4.20E-07 4.51E-07 4.79E-07 5.21E-07 4.80E-07 4.40E-07883 4.21E-07 4.59E-07 4.90E-07 5.13E-07 5.60E-07 5.17E-07 4.74E-07885 3.67E-07 4.03E-07 4.40E-07 4.67E-07 5.09E-07 4.66E-07 4.24E-07886 3.67E-07 3.97E-07 4.27E-07 4.53E-07 4.99E-07 4.81E-07 4.24E-07887 3.87E-07 4.18E-07 4.49E-07 4.78E-07 5.21E-07 5.05E-07 4.45E-07891 3.98E-07 4.29E-07 4.57E-07 4.83E-07 5.27E-07 5.10E-07 4.54E-07892 4.32E-07 4.63E-07 4.94E-07 5.24E-07 5.74E-07 5.55E-07 4.92E-07895 4.05E-07 4.36E-07 4.69E-07 4.98E-07 5.48E-07 5.27E-07 4.64E-07896 3.93E-07 4.05E-07 4.05E-07 4.05E-07 4.04E-07 4.06E-07 4.05E-07

Biased StatisticsAverage Biased 3.77E-07 4.12E-07 4.43E-07 4.70E-07 5.14E-07 4.72E-07 4.33E-07Std Dev Biased 2.94E-08 3.15E-08 3.13E-08 3.00E-08 3.03E-08 3.00E-08 2.80E-08Ps90%/90% (+KTL) Biased 4.58E-07 4.98E-07 5.29E-07 5.52E-07 5.98E-07 5.55E-07 5.09E-07Ps90%/90% (-KTL) Biased 2.96E-07 3.25E-07 3.57E-07 3.88E-07 4.31E-07 3.90E-07 3.56E-07Un-Biased StatisticsAverage Un-Biased 3.98E-07 4.29E-07 4.59E-07 4.87E-07 5.34E-07 5.15E-07 4.56E-07Std Dev Un-Biased 2.40E-08 2.41E-08 2.47E-08 2.63E-08 2.83E-08 2.76E-08 2.47E-08Ps90%/90% (+KTL) Un-Biased 4.64E-07 4.95E-07 5.27E-07 5.59E-07 6.12E-07 5.91E-07 5.24E-07Ps90%/90% (-KTL) Un-Biased 3.32E-07 3.62E-07 3.92E-07 4.15E-07 4.56E-07 4.40E-07 3.88E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 71: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

71

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 15

V #

2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.32. Plot of Negative Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 72: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

72

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.32. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.68E-07 4.04E-07 4.38E-07 4.63E-07 5.04E-07 4.64E-07 4.26E-07879 4.23E-07 4.47E-07 4.71E-07 5.00E-07 5.55E-07 5.17E-07 4.80E-07882 3.57E-07 3.87E-07 4.17E-07 4.42E-07 4.84E-07 4.46E-07 4.10E-07883 4.13E-07 4.49E-07 4.80E-07 5.02E-07 5.50E-07 5.08E-07 4.65E-07885 4.07E-07 4.38E-07 4.73E-07 5.05E-07 5.43E-07 5.05E-07 4.62E-07886 3.74E-07 4.03E-07 4.34E-07 4.60E-07 5.02E-07 4.86E-07 4.33E-07887 4.18E-07 4.49E-07 4.78E-07 5.07E-07 5.53E-07 5.36E-07 4.78E-07891 3.89E-07 4.20E-07 4.49E-07 4.76E-07 5.17E-07 5.03E-07 4.50E-07892 4.14E-07 4.46E-07 4.75E-07 5.04E-07 5.51E-07 5.33E-07 4.73E-07895 3.53E-07 3.84E-07 4.16E-07 4.44E-07 4.90E-07 4.72E-07 4.14E-07896 3.76E-07 3.91E-07 3.90E-07 3.90E-07 3.89E-07 3.91E-07 3.91E-07

Biased StatisticsAverage Biased 3.94E-07 4.25E-07 4.56E-07 4.82E-07 5.27E-07 4.88E-07 4.48E-07Std Dev Biased 2.93E-08 2.78E-08 2.70E-08 2.84E-08 3.14E-08 3.12E-08 2.93E-08Ps90%/90% (+KTL) Biased 4.74E-07 5.01E-07 5.30E-07 5.60E-07 6.13E-07 5.74E-07 5.29E-07Ps90%/90% (-KTL) Biased 3.13E-07 3.49E-07 3.82E-07 4.04E-07 4.41E-07 4.02E-07 3.68E-07Un-Biased StatisticsAverage Un-Biased 3.90E-07 4.20E-07 4.50E-07 4.78E-07 5.23E-07 5.06E-07 4.49E-07Std Dev Un-Biased 2.74E-08 2.77E-08 2.66E-08 2.76E-08 2.85E-08 2.83E-08 2.69E-08Ps90%/90% (+KTL) Un-Biased 4.65E-07 4.96E-07 5.23E-07 5.54E-07 6.01E-07 5.84E-07 5.23E-07Ps90%/90% (-KTL) Un-Biased 3.14E-07 3.44E-07 3.77E-07 4.02E-07 4.44E-07 4.28E-07 3.76E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 73: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

73

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 15

V #

3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.33. Plot of Negative Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 74: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

74

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.33. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.59E-07 3.92E-07 4.22E-07 4.47E-07 4.90E-07 4.51E-07 4.13E-07879 4.25E-07 4.49E-07 5.00E-07 5.07E-07 5.63E-07 5.23E-07 4.86E-07882 3.60E-07 4.11E-07 4.26E-07 4.48E-07 4.89E-07 4.53E-07 4.14E-07883 4.00E-07 4.34E-07 4.63E-07 5.19E-07 5.38E-07 4.97E-07 4.53E-07885 4.22E-07 4.54E-07 4.88E-07 5.24E-07 5.62E-07 5.19E-07 4.75E-07886 3.70E-07 4.00E-07 4.30E-07 4.55E-07 4.97E-07 4.83E-07 4.29E-07887 4.18E-07 4.46E-07 4.76E-07 5.03E-07 5.48E-07 5.33E-07 4.75E-07891 3.87E-07 4.21E-07 4.50E-07 4.76E-07 5.19E-07 5.05E-07 4.52E-07892 4.21E-07 4.53E-07 4.83E-07 5.13E-07 5.58E-07 5.40E-07 4.79E-07895 3.72E-07 4.04E-07 4.35E-07 4.60E-07 5.08E-07 4.89E-07 4.31E-07896 3.65E-07 3.77E-07 3.76E-07 3.77E-07 3.75E-07 3.76E-07 3.77E-07

Biased StatisticsAverage Biased 3.93E-07 4.28E-07 4.60E-07 4.89E-07 5.29E-07 4.89E-07 4.48E-07Std Dev Biased 3.22E-08 2.64E-08 3.54E-08 3.83E-08 3.68E-08 3.47E-08 3.38E-08Ps90%/90% (+KTL) Biased 4.82E-07 5.00E-07 5.57E-07 5.94E-07 6.29E-07 5.84E-07 5.41E-07Ps90%/90% (-KTL) Biased 3.05E-07 3.55E-07 3.63E-07 3.84E-07 4.28E-07 3.93E-07 3.56E-07Un-Biased StatisticsAverage Un-Biased 3.93E-07 4.25E-07 4.55E-07 4.81E-07 5.26E-07 5.10E-07 4.53E-07Std Dev Un-Biased 2.47E-08 2.42E-08 2.40E-08 2.58E-08 2.61E-08 2.55E-08 2.36E-08Ps90%/90% (+KTL) Un-Biased 4.61E-07 4.91E-07 5.20E-07 5.52E-07 5.98E-07 5.80E-07 5.18E-07Ps90%/90% (-KTL) Un-Biased 3.26E-07 3.58E-07 3.89E-07 4.11E-07 4.54E-07 4.40E-07 3.89E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 75: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

75

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= 15

V #

4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.34. Plot of Negative Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 76: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

76

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.34. Raw data for Negative Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.55E-07 3.86E-07 4.15E-07 4.42E-07 4.83E-07 4.45E-07 4.08E-07879 3.82E-07 4.14E-07 4.67E-07 4.72E-07 5.23E-07 4.79E-07 4.43E-07882 3.88E-07 4.37E-07 4.55E-07 4.80E-07 5.21E-07 4.81E-07 4.41E-07883 4.28E-07 4.63E-07 4.94E-07 5.50E-07 5.68E-07 5.28E-07 4.81E-07885 3.57E-07 3.87E-07 4.21E-07 4.53E-07 4.90E-07 4.50E-07 4.09E-07886 3.63E-07 3.91E-07 4.20E-07 4.45E-07 4.91E-07 4.76E-07 4.20E-07887 3.91E-07 4.23E-07 4.56E-07 4.83E-07 5.28E-07 5.10E-07 4.49E-07891 4.04E-07 4.34E-07 4.64E-07 4.88E-07 5.30E-07 5.15E-07 4.58E-07892 4.35E-07 4.68E-07 4.97E-07 5.29E-07 5.77E-07 5.59E-07 4.94E-07895 4.04E-07 4.36E-07 4.68E-07 4.96E-07 5.47E-07 5.27E-07 4.65E-07896 3.91E-07 4.07E-07 4.07E-07 4.08E-07 4.04E-07 4.07E-07 4.04E-07

Biased StatisticsAverage Biased 3.82E-07 4.17E-07 4.50E-07 4.80E-07 5.17E-07 4.77E-07 4.36E-07Std Dev Biased 2.99E-08 3.31E-08 3.28E-08 4.25E-08 3.37E-08 3.31E-08 3.02E-08Ps90%/90% (+KTL) Biased 4.64E-07 5.08E-07 5.40E-07 5.96E-07 6.09E-07 5.67E-07 5.19E-07Ps90%/90% (-KTL) Biased 3.00E-07 3.27E-07 3.60E-07 3.63E-07 4.25E-07 3.86E-07 3.53E-07Un-Biased StatisticsAverage Un-Biased 3.99E-07 4.30E-07 4.61E-07 4.88E-07 5.34E-07 5.18E-07 4.58E-07Std Dev Un-Biased 2.61E-08 2.77E-08 2.80E-08 3.00E-08 3.14E-08 2.98E-08 2.68E-08Ps90%/90% (+KTL) Un-Biased 4.71E-07 5.06E-07 5.38E-07 5.71E-07 6.20E-07 5.99E-07 5.31E-07Ps90%/90% (-KTL) Un-Biased 3.28E-07 3.55E-07 3.84E-07 4.06E-07 4.48E-07 4.36E-07 3.84E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 77: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

77

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

-15

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.35. Plot of Input Offset Voltage @ +/- 15V, VCM= -15 V #1 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 78: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

78

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.35. Raw data for Input Offset Voltage @ +/- 15V, VCM= -15 V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= -15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.94E-04 -3.09E-04 -2.98E-04 -2.89E-04 -2.89E-04 -2.91E-04 -3.17E-04879 -5.12E-05 -8.22E-05 -6.65E-05 -8.04E-05 -9.38E-05 -8.95E-05 -8.22E-05882 -1.31E-04 -1.40E-04 -1.36E-04 -1.37E-04 -1.39E-04 -1.32E-04 -1.51E-04883 -1.01E-04 -1.16E-04 -1.13E-04 -9.59E-05 -1.09E-04 -1.11E-04 -1.21E-04885 -3.02E-04 -3.20E-04 -3.10E-04 -3.17E-04 -3.11E-04 -3.13E-04 -3.19E-04886 1.38E-04 1.20E-04 1.11E-04 1.08E-04 9.97E-05 9.90E-05 9.92E-05887 -2.53E-04 -2.64E-04 -2.69E-04 -2.72E-04 -2.82E-04 -2.82E-04 -2.85E-04891 -7.48E-05 -9.14E-05 -9.47E-05 -1.03E-04 -1.08E-04 -1.08E-04 -1.14E-04892 -2.55E-04 -2.68E-04 -2.73E-04 -2.80E-04 -2.89E-04 -2.85E-04 -2.86E-04895 -1.49E-04 -1.64E-04 -1.70E-04 -1.75E-04 -1.88E-04 -1.88E-04 -1.78E-04896 1.66E-04 1.42E-04 1.43E-04 1.42E-04 1.44E-04 1.43E-04 1.44E-04

Biased StatisticsAverage Biased -1.76E-04 -1.93E-04 -1.85E-04 -1.84E-04 -1.88E-04 -1.87E-04 -1.98E-04Std Dev Biased 1.15E-04 1.13E-04 1.12E-04 1.11E-04 1.03E-04 1.06E-04 1.12E-04Ps90%/90% (+KTL) Biased 1.40E-04 1.15E-04 1.22E-04 1.21E-04 9.49E-05 1.03E-04 1.09E-04Ps90%/90% (-KTL) Biased -4.92E-04 -5.02E-04 -4.91E-04 -4.89E-04 -4.72E-04 -4.78E-04 -5.05E-04Un-Biased StatisticsAverage Un-Biased -1.19E-04 -1.34E-04 -1.39E-04 -1.44E-04 -1.54E-04 -1.53E-04 -1.53E-04Std Dev Un-Biased 1.62E-04 1.60E-04 1.58E-04 1.59E-04 1.60E-04 1.59E-04 1.59E-04Ps90%/90% (+KTL) Un-Biased 3.27E-04 3.04E-04 2.95E-04 2.92E-04 2.85E-04 2.82E-04 2.83E-04Ps90%/90% (-KTL) Un-Biased -5.64E-04 -5.71E-04 -5.74E-04 -5.81E-04 -5.93E-04 -5.88E-04 -5.89E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 79: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

79

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

-15

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.36. Plot of Input Offset Voltage @ +/- 15V, VCM= -15 V #2 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 80: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

80

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.36. Raw data for Input Offset Voltage @ +/- 15V, VCM= -15 V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= -15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.75E-04 -3.91E-04 -3.84E-04 -3.45E-04 -3.08E-04 -3.57E-04 -3.91E-04879 -1.20E-04 -1.20E-04 -1.01E-04 -1.10E-04 -1.22E-04 -1.16E-04 -1.23E-04882 5.19E-05 3.14E-05 2.85E-05 3.21E-05 3.25E-05 3.25E-05 1.15E-05883 -5.42E-05 -7.09E-05 -5.98E-05 -3.99E-05 -4.65E-05 -6.73E-06 -7.36E-05885 2.26E-05 2.58E-05 5.36E-05 2.93E-05 2.43E-05 1.51E-05 4.02E-06886 2.93E-04 2.71E-04 2.66E-04 2.61E-04 2.59E-04 2.54E-04 2.56E-04887 -1.42E-04 -1.45E-04 -1.46E-04 -1.51E-04 -1.55E-04 -1.60E-04 -1.75E-04891 2.70E-04 2.64E-04 2.64E-04 2.57E-04 2.51E-04 2.46E-04 2.55E-04892 4.52E-05 3.69E-05 3.59E-05 3.18E-05 2.77E-05 2.63E-05 1.36E-05895 -4.90E-05 -6.12E-05 -6.59E-05 -6.85E-05 -7.12E-05 -7.35E-05 -7.96E-05896 -5.87E-06 -1.87E-05 -1.65E-05 -1.65E-05 -1.80E-05 -1.66E-05 -1.72E-05

Biased StatisticsAverage Biased -9.49E-05 -1.05E-04 -9.25E-05 -8.67E-05 -8.40E-05 -8.64E-05 -1.14E-04Std Dev Biased 1.70E-04 1.73E-04 1.75E-04 1.56E-04 1.40E-04 1.62E-04 1.64E-04Ps90%/90% (+KTL) Biased 3.72E-04 3.68E-04 3.87E-04 3.40E-04 3.00E-04 3.58E-04 3.36E-04Ps90%/90% (-KTL) Biased -5.62E-04 -5.78E-04 -5.71E-04 -5.13E-04 -4.68E-04 -5.31E-04 -5.65E-04Un-Biased StatisticsAverage Un-Biased 8.35E-05 7.32E-05 7.07E-05 6.62E-05 6.22E-05 5.86E-05 5.39E-05Std Dev Un-Biased 1.93E-04 1.89E-04 1.88E-04 1.88E-04 1.87E-04 1.87E-04 1.96E-04Ps90%/90% (+KTL) Un-Biased 6.12E-04 5.91E-04 5.88E-04 5.80E-04 5.75E-04 5.71E-04 5.91E-04Ps90%/90% (-KTL) Un-Biased -4.45E-04 -4.44E-04 -4.46E-04 -4.48E-04 -4.51E-04 -4.53E-04 -4.83E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 81: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

81

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

-15

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.37. Plot of Input Offset Voltage @ +/- 15V, VCM= -15 V #3 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 82: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

82

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.37. Raw data for Input Offset Voltage @ +/- 15V, VCM= -15 V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= -15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.35E-05 -4.80E-05 -3.99E-05 -3.40E-05 -3.41E-05 -3.58E-05 -4.97E-05879 1.70E-04 1.33E-04 1.54E-04 1.38E-04 1.33E-04 1.32E-04 1.31E-04882 -2.03E-04 -2.34E-04 -2.22E-04 -2.23E-04 -2.21E-04 -2.25E-04 -2.47E-04883 9.15E-05 6.38E-05 6.51E-05 8.40E-05 6.04E-05 6.73E-05 3.51E-05885 -2.26E-04 -2.42E-04 -2.36E-04 -2.39E-04 -2.46E-04 -2.46E-04 -2.67E-04886 -3.12E-04 -3.27E-04 -3.31E-04 -3.37E-04 -3.43E-04 -3.41E-04 -3.41E-04887 -1.57E-04 -1.65E-04 -1.69E-04 -1.78E-04 -1.90E-04 -1.91E-04 -1.71E-04891 -1.14E-04 -1.27E-04 -1.28E-04 -1.33E-04 -1.39E-04 -1.40E-04 -1.46E-04892 5.39E-05 4.07E-05 3.95E-05 3.22E-05 2.41E-05 2.53E-05 2.25E-05895 -1.05E-04 -1.22E-04 -1.26E-04 -1.28E-04 -1.31E-04 -1.32E-04 -1.29E-04896 3.82E-04 3.36E-04 3.37E-04 3.39E-04 3.42E-04 3.41E-04 3.40E-04

Biased StatisticsAverage Biased -3.83E-05 -6.55E-05 -5.59E-05 -5.49E-05 -6.16E-05 -6.17E-05 -7.94E-05Std Dev Biased 1.75E-04 1.70E-04 1.73E-04 1.73E-04 1.68E-04 1.70E-04 1.74E-04Ps90%/90% (+KTL) Biased 4.42E-04 4.01E-04 4.17E-04 4.19E-04 3.99E-04 4.04E-04 3.99E-04Ps90%/90% (-KTL) Biased -5.19E-04 -5.32E-04 -5.29E-04 -5.29E-04 -5.22E-04 -5.28E-04 -5.57E-04Un-Biased StatisticsAverage Un-Biased -1.27E-04 -1.40E-04 -1.43E-04 -1.49E-04 -1.56E-04 -1.56E-04 -1.53E-04Std Dev Un-Biased 1.31E-04 1.31E-04 1.32E-04 1.32E-04 1.32E-04 1.31E-04 1.29E-04Ps90%/90% (+KTL) Un-Biased 2.32E-04 2.19E-04 2.19E-04 2.13E-04 2.05E-04 2.05E-04 2.02E-04Ps90%/90% (-KTL) Un-Biased -4.86E-04 -4.99E-04 -5.05E-04 -5.10E-04 -5.17E-04 -5.16E-04 -5.08E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 83: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

83

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

+/-

15V,

VC

M=

-15

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.38. Plot of Input Offset Voltage @ +/- 15V, VCM= -15 V #4 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 84: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

84

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.38. Raw data for Input Offset Voltage @ +/- 15V, VCM= -15 V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ +/- 15V, VCM= -15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.41E-04 -2.63E-04 -2.52E-04 -2.49E-04 -2.39E-04 -2.42E-04 -2.55E-04879 -1.26E-05 -4.32E-05 -2.69E-05 -4.02E-05 -4.71E-05 -4.15E-05 -5.92E-05882 -3.78E-05 -6.10E-05 -4.85E-05 -4.42E-05 -3.56E-05 -4.27E-05 -5.36E-05883 -1.19E-04 -1.33E-04 -1.26E-04 -1.02E-04 -1.23E-04 -1.23E-04 -1.53E-04885 -1.88E-05 -4.74E-05 -4.26E-05 -4.03E-05 -4.79E-05 -5.24E-05 -8.20E-05886 1.45E-04 1.21E-04 1.16E-04 1.07E-04 1.03E-04 9.87E-05 9.90E-05887 -1.97E-04 -2.11E-04 -2.17E-04 -2.18E-04 -2.28E-04 -2.29E-04 -2.32E-04891 1.58E-04 1.39E-04 1.37E-04 1.33E-04 1.27E-04 1.24E-04 1.27E-04892 1.09E-04 1.09E-04 1.08E-04 1.03E-04 1.01E-04 9.88E-05 9.67E-05895 4.37E-05 2.81E-05 2.21E-05 1.33E-05 -1.77E-06 -2.50E-06 2.93E-06896 1.64E-04 1.37E-04 1.33E-04 1.33E-04 1.35E-04 1.34E-04 1.37E-04

Biased StatisticsAverage Biased -8.59E-05 -1.09E-04 -9.91E-05 -9.51E-05 -9.86E-05 -1.00E-04 -1.21E-04Std Dev Biased 9.66E-05 9.33E-05 9.35E-05 8.98E-05 8.60E-05 8.60E-05 8.51E-05Ps90%/90% (+KTL) Biased 1.79E-04 1.46E-04 1.57E-04 1.51E-04 1.37E-04 1.36E-04 1.13E-04Ps90%/90% (-KTL) Biased -3.51E-04 -3.65E-04 -3.56E-04 -3.41E-04 -3.34E-04 -3.36E-04 -3.54E-04Un-Biased StatisticsAverage Un-Biased 5.18E-05 3.74E-05 3.30E-05 2.76E-05 2.01E-05 1.79E-05 1.86E-05Std Dev Un-Biased 1.46E-04 1.45E-04 1.47E-04 1.45E-04 1.48E-04 1.46E-04 1.48E-04Ps90%/90% (+KTL) Un-Biased 4.52E-04 4.35E-04 4.35E-04 4.24E-04 4.25E-04 4.19E-04 4.24E-04Ps90%/90% (-KTL) Un-Biased -3.48E-04 -3.60E-04 -3.69E-04 -3.69E-04 -3.84E-04 -3.84E-04 -3.86E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 85: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

85

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

-15

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.39. Plot of Input Offset Current @ +/- 15V, VCM= -15 V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 86: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

86

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.39. Raw data for Input Offset Current @ +/- 15V, VCM= -15 V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= -15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.44E-10 5.13E-10 8.41E-10 1.01E-09 6.50E-11 2.22E-10 5.59E-10879 -1.08E-10 -8.00E-12 -7.30E-11 -5.38E-10 1.04E-09 9.57E-10 6.32E-10882 -4.23E-09 -4.48E-09 -4.29E-09 -4.63E-09 -4.55E-09 -3.90E-09 -4.11E-09883 -2.80E-09 -2.43E-09 -2.32E-09 -2.54E-09 -3.45E-09 -2.82E-09 -2.94E-09885 -2.56E-09 -3.44E-09 -2.75E-09 -1.31E-09 -2.10E-09 -2.80E-09 -2.57E-09886 4.09E-09 3.79E-09 3.15E-09 2.97E-09 3.36E-09 3.57E-09 3.30E-09887 2.34E-09 2.31E-09 2.31E-09 1.83E-09 1.69E-09 1.91E-09 1.91E-09891 -5.98E-10 -6.60E-10 -9.03E-10 -7.64E-10 -3.20E-11 -5.10E-10 -2.53E-09892 -2.53E-09 -2.76E-09 -2.79E-09 -2.22E-09 -2.83E-09 -3.17E-09 -2.59E-09895 6.99E-10 1.37E-09 1.44E-09 1.46E-09 2.01E-09 1.63E-09 1.50E-09896 7.33E-10 7.65E-10 7.00E-10 7.45E-10 7.39E-10 7.63E-10 7.64E-10

Biased StatisticsAverage Biased -1.79E-09 -1.97E-09 -1.72E-09 -1.60E-09 -1.80E-09 -1.67E-09 -1.68E-09Std Dev Biased 2.05E-09 2.16E-09 2.08E-09 2.13E-09 2.34E-09 2.12E-09 2.16E-09Ps90%/90% (+KTL) Biased 3.83E-09 3.96E-09 3.98E-09 4.23E-09 4.62E-09 4.16E-09 4.23E-09Ps90%/90% (-KTL) Biased -7.41E-09 -7.89E-09 -7.42E-09 -7.43E-09 -8.23E-09 -7.49E-09 -7.60E-09Un-Biased StatisticsAverage Un-Biased 7.99E-10 8.08E-10 6.41E-10 6.54E-10 8.39E-10 6.85E-10 3.19E-10Std Dev Un-Biased 2.56E-09 2.57E-09 2.44E-09 2.10E-09 2.38E-09 2.60E-09 2.71E-09Ps90%/90% (+KTL) Un-Biased 7.82E-09 7.84E-09 7.34E-09 6.41E-09 7.36E-09 7.82E-09 7.75E-09Ps90%/90% (-KTL) Un-Biased -6.22E-09 -6.23E-09 -6.06E-09 -5.10E-09 -5.68E-09 -6.45E-09 -7.11E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 87: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

87

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

-15

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.40. Plot of Input Offset Current @ +/- 15V, VCM= -15 V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 88: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

88

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.40. Raw data for Input Offset Current @ +/- 15V, VCM= -15 V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= -15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -1.62E-09 -2.23E-09 -2.15E-09 2.09E-09 6.47E-09 -1.80E-09 -1.40E-09879 -6.11E-09 -6.40E-09 -6.51E-09 -5.86E-09 -4.35E-09 -4.71E-09 -5.28E-09882 -3.42E-09 -3.80E-09 -4.11E-09 -3.86E-09 -3.87E-09 -4.20E-09 -3.81E-09883 7.00E-12 -5.63E-10 -5.51E-10 -6.20E-11 8.21E-10 7.54E-09 -2.31E-10885 8.85E-10 2.56E-09 4.21E-09 3.10E-09 6.20E-10 1.28E-09 1.31E-09886 3.17E-10 2.42E-10 6.39E-10 9.47E-10 1.38E-09 1.46E-09 6.53E-10887 -6.17E-09 -6.34E-09 -5.98E-09 -6.08E-09 -6.11E-09 -6.58E-09 -6.17E-09891 3.77E-10 1.64E-10 8.90E-10 1.80E-10 6.70E-11 1.18E-10 2.94E-10892 1.19E-09 1.29E-09 1.08E-09 1.60E-09 1.76E-09 1.63E-09 1.51E-09895 2.22E-09 1.85E-09 1.98E-09 1.15E-09 1.96E-09 1.89E-09 1.58E-09896 1.22E-09 1.16E-09 1.21E-09 1.19E-09 1.20E-09 1.18E-09 1.14E-09

Biased StatisticsAverage Biased -2.05E-09 -2.09E-09 -1.82E-09 -9.21E-10 -6.20E-11 -3.78E-10 -1.88E-09Std Dev Biased 2.80E-09 3.37E-09 4.04E-09 3.84E-09 4.38E-09 5.02E-09 2.66E-09Ps90%/90% (+KTL) Biased 5.63E-09 7.16E-09 9.25E-09 9.61E-09 1.20E-08 1.34E-08 5.43E-09Ps90%/90% (-KTL) Biased -9.73E-09 -1.13E-08 -1.29E-08 -1.15E-08 -1.21E-08 -1.41E-08 -9.19E-09Un-Biased StatisticsAverage Un-Biased -4.13E-10 -5.58E-10 -2.79E-10 -4.41E-10 -1.89E-10 -2.96E-10 -4.26E-10Std Dev Un-Biased 3.31E-09 3.31E-09 3.23E-09 3.19E-09 3.39E-09 3.58E-09 3.26E-09Ps90%/90% (+KTL) Un-Biased 8.66E-09 8.51E-09 8.56E-09 8.32E-09 9.11E-09 9.51E-09 8.50E-09Ps90%/90% (-KTL) Un-Biased -9.49E-09 -9.63E-09 -9.12E-09 -9.20E-09 -9.49E-09 -1.01E-08 -9.36E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 89: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

89

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

-15

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.41. Plot of Input Offset Current @ +/- 15V, VCM= -15 V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 90: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

90

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.41. Raw data for Input Offset Current @ +/- 15V, VCM= -15 V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= -15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.70E-09 5.53E-09 5.85E-09 5.81E-09 5.64E-09 5.32E-09 6.19E-09879 -3.79E-09 -4.46E-09 -4.17E-09 -4.44E-09 -2.91E-09 -2.96E-09 -2.84E-09882 -1.83E-09 -1.96E-09 -2.35E-09 -2.66E-09 -2.88E-09 -3.11E-09 -2.53E-09883 2.80E-09 2.55E-09 2.52E-09 3.21E-09 2.09E-09 2.14E-09 2.38E-09885 3.89E-09 3.78E-09 3.68E-09 4.76E-09 4.34E-09 3.41E-09 4.38E-09886 1.12E-09 5.89E-10 8.62E-10 5.33E-10 1.61E-09 1.47E-09 9.52E-10887 -2.48E-09 -2.70E-09 -2.53E-09 -2.38E-09 -2.60E-09 -2.45E-09 -2.54E-09891 2.31E-09 2.14E-09 2.35E-09 2.41E-09 1.64E-09 1.75E-09 2.08E-09892 7.08E-10 1.06E-09 1.39E-09 1.10E-09 1.01E-09 9.85E-10 8.58E-10895 1.16E-09 5.42E-10 1.07E-09 1.15E-09 8.33E-10 1.56E-09 1.35E-09896 2.49E-09 2.56E-09 2.60E-09 2.55E-09 2.56E-09 2.56E-09 2.57E-09

Biased StatisticsAverage Biased 1.36E-09 1.09E-09 1.11E-09 1.33E-09 1.26E-09 9.60E-10 1.52E-09Std Dev Biased 4.00E-09 4.16E-09 4.21E-09 4.60E-09 4.00E-09 3.82E-09 4.07E-09Ps90%/90% (+KTL) Biased 1.23E-08 1.25E-08 1.26E-08 1.39E-08 1.22E-08 1.14E-08 1.27E-08Ps90%/90% (-KTL) Biased -9.61E-09 -1.03E-08 -1.04E-08 -1.13E-08 -9.70E-09 -9.51E-09 -9.64E-09Un-Biased StatisticsAverage Un-Biased 5.63E-10 3.25E-10 6.28E-10 5.63E-10 5.00E-10 6.62E-10 5.40E-10Std Dev Un-Biased 1.80E-09 1.81E-09 1.85E-09 1.78E-09 1.77E-09 1.76E-09 1.79E-09Ps90%/90% (+KTL) Un-Biased 5.50E-09 5.29E-09 5.71E-09 5.45E-09 5.35E-09 5.49E-09 5.44E-09Ps90%/90% (-KTL) Un-Biased -4.38E-09 -4.64E-09 -4.46E-09 -4.32E-09 -4.35E-09 -4.17E-09 -4.36E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 91: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

91

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-07

-1.00E-07

-5.00E-08

0.00E+00

5.00E-08

1.00E-07

1.50E-07

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

+/-

15V,

VC

M=

-15

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.42. Plot of Input Offset Current @ +/- 15V, VCM= -15 V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 92: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

92

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.42. Raw data for Input Offset Current @ +/- 15V, VCM= -15 V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ +/- 15V, VCM= -15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.88E-09 -4.02E-09 -2.97E-09 -3.11E-09 -3.31E-09 -3.16E-09 -3.11E-09879 -3.45E-09 -3.96E-09 -3.61E-09 -3.49E-09 -1.88E-09 -2.70E-09 -2.61E-09882 2.55E-09 2.60E-09 2.15E-09 2.02E-09 2.28E-09 2.11E-09 2.23E-09883 -3.07E-09 -3.60E-09 -3.76E-09 -1.90E-09 -2.50E-09 -2.64E-09 -3.26E-09885 1.47E-10 2.36E-10 6.09E-10 2.22E-09 8.42E-10 1.13E-09 9.04E-10886 -3.00E-12 -2.90E-10 -3.00E-12 -6.87E-10 -6.82E-10 -1.24E-09 -5.57E-10887 -2.45E-09 -2.42E-09 -3.02E-09 -2.98E-09 -2.82E-09 -2.40E-09 -3.04E-09891 -2.31E-09 -2.29E-09 -2.37E-09 -2.56E-09 -2.35E-09 -2.17E-09 -2.24E-09892 2.22E-09 2.16E-09 2.42E-09 2.37E-09 2.26E-09 1.95E-09 1.25E-09895 -4.36E-09 -4.57E-09 -4.19E-09 -4.44E-09 -4.45E-09 -4.88E-09 -4.86E-09896 5.68E-09 5.76E-09 5.77E-09 5.77E-09 5.70E-09 5.75E-09 5.78E-09

Biased StatisticsAverage Biased -1.54E-09 -1.75E-09 -1.51E-09 -8.51E-10 -9.14E-10 -1.05E-09 -1.17E-09Std Dev Biased 2.78E-09 3.01E-09 2.71E-09 2.78E-09 2.37E-09 2.47E-09 2.55E-09Ps90%/90% (+KTL) Biased 6.09E-09 6.52E-09 5.93E-09 6.76E-09 5.59E-09 5.73E-09 5.83E-09Ps90%/90% (-KTL) Biased -9.17E-09 -1.00E-08 -8.96E-09 -8.46E-09 -7.42E-09 -7.83E-09 -8.17E-09Un-Biased StatisticsAverage Un-Biased -1.38E-09 -1.48E-09 -1.43E-09 -1.66E-09 -1.61E-09 -1.75E-09 -1.89E-09Std Dev Un-Biased 2.53E-09 2.54E-09 2.64E-09 2.62E-09 2.55E-09 2.47E-09 2.34E-09Ps90%/90% (+KTL) Un-Biased 5.57E-09 5.48E-09 5.81E-09 5.52E-09 5.37E-09 5.02E-09 4.52E-09Ps90%/90% (-KTL) Un-Biased -8.33E-09 -8.44E-09 -8.67E-09 -8.84E-09 -8.59E-09 -8.51E-09 -8.31E-09Specification MIN -7.00E-08 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07 -1.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.00E-08 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07 1.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 93: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

93

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

-15

V #1

(A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.43. Plot of Positive Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 94: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

94

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.43. Raw data for Positive Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.88E-07 -2.94E-07 -3.00E-07 -3.05E-07 -3.12E-07 -3.01E-07 -2.97E-07879 -3.02E-07 -3.08E-07 -3.13E-07 -3.18E-07 -3.34E-07 -3.17E-07 -3.12E-07882 -3.15E-07 -3.24E-07 -3.29E-07 -3.34E-07 -3.41E-07 -3.30E-07 -3.24E-07883 -3.13E-07 -3.21E-07 -3.25E-07 -3.30E-07 -3.36E-07 -3.26E-07 -3.20E-07885 -2.96E-07 -3.04E-07 -3.09E-07 -3.18E-07 -3.22E-07 -3.12E-07 -3.06E-07886 -2.89E-07 -2.98E-07 -3.06E-07 -3.12E-07 -3.22E-07 -3.19E-07 -3.03E-07887 -3.07E-07 -3.16E-07 -3.23E-07 -3.30E-07 -3.41E-07 -3.37E-07 -3.19E-07891 -3.14E-07 -3.23E-07 -3.29E-07 -3.35E-07 -3.49E-07 -3.41E-07 -3.27E-07892 -3.16E-07 -3.23E-07 -3.28E-07 -3.33E-07 -3.47E-07 -3.40E-07 -3.25E-07895 -3.09E-07 -3.18E-07 -3.25E-07 -3.31E-07 -3.46E-07 -3.38E-07 -3.22E-07896 -3.16E-07 -3.30E-07 -3.29E-07 -3.29E-07 -3.28E-07 -3.29E-07 -3.29E-07

Biased StatisticsAverage Biased -3.03E-07 -3.10E-07 -3.15E-07 -3.21E-07 -3.29E-07 -3.17E-07 -3.12E-07Std Dev Biased 1.14E-08 1.23E-08 1.18E-08 1.14E-08 1.18E-08 1.13E-08 1.07E-08Ps90%/90% (+KTL) Biased -2.71E-07 -2.76E-07 -2.83E-07 -2.90E-07 -2.97E-07 -2.86E-07 -2.82E-07Ps90%/90% (-KTL) Biased -3.34E-07 -3.44E-07 -3.48E-07 -3.52E-07 -3.61E-07 -3.48E-07 -3.41E-07Un-Biased StatisticsAverage Un-Biased -3.07E-07 -3.16E-07 -3.22E-07 -3.28E-07 -3.41E-07 -3.35E-07 -3.19E-07Std Dev Un-Biased 1.07E-08 1.02E-08 9.44E-09 9.39E-09 1.08E-08 9.23E-09 9.71E-09Ps90%/90% (+KTL) Un-Biased -2.78E-07 -2.87E-07 -2.96E-07 -3.02E-07 -3.11E-07 -3.10E-07 -2.92E-07Ps90%/90% (-KTL) Un-Biased -3.36E-07 -3.44E-07 -3.48E-07 -3.54E-07 -3.71E-07 -3.60E-07 -3.46E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 95: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

95

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

-15

V #2

(A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.44. Plot of Positive Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 96: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

96

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.44. Raw data for Positive Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.98E-07 -3.04E-07 -3.10E-07 -3.14E-07 -3.20E-07 -3.12E-07 -3.08E-07879 -3.18E-07 -3.21E-07 -3.23E-07 -3.26E-07 -3.40E-07 -3.29E-07 -3.26E-07882 -2.97E-07 -3.05E-07 -3.10E-07 -3.15E-07 -3.22E-07 -3.11E-07 -3.06E-07883 -2.95E-07 -3.02E-07 -3.07E-07 -3.10E-07 -3.15E-07 -3.05E-07 -3.00E-07885 -3.04E-07 -3.11E-07 -3.15E-07 -3.25E-07 -3.28E-07 -3.18E-07 -3.12E-07886 -2.96E-07 -3.06E-07 -3.12E-07 -3.19E-07 -3.29E-07 -3.26E-07 -3.10E-07887 -3.15E-07 -3.21E-07 -3.26E-07 -3.30E-07 -3.38E-07 -3.37E-07 -3.25E-07891 -2.97E-07 -3.07E-07 -3.12E-07 -3.19E-07 -3.29E-07 -3.27E-07 -3.11E-07892 -3.01E-07 -3.09E-07 -3.15E-07 -3.21E-07 -3.30E-07 -3.27E-07 -3.12E-07895 -2.86E-07 -2.94E-07 -3.00E-07 -3.07E-07 -3.17E-07 -3.14E-07 -2.99E-07896 -2.95E-07 -3.08E-07 -3.08E-07 -3.08E-07 -3.07E-07 -3.07E-07 -3.08E-07

Biased StatisticsAverage Biased -3.02E-07 -3.09E-07 -3.13E-07 -3.18E-07 -3.25E-07 -3.15E-07 -3.10E-07Std Dev Biased 9.18E-09 7.43E-09 6.34E-09 7.10E-09 9.60E-09 9.05E-09 9.60E-09Ps90%/90% (+KTL) Biased -2.77E-07 -2.88E-07 -2.96E-07 -2.99E-07 -2.99E-07 -2.90E-07 -2.84E-07Ps90%/90% (-KTL) Biased -3.28E-07 -3.29E-07 -3.31E-07 -3.38E-07 -3.51E-07 -3.40E-07 -3.37E-07Un-Biased StatisticsAverage Un-Biased -2.99E-07 -3.07E-07 -3.13E-07 -3.19E-07 -3.29E-07 -3.26E-07 -3.11E-07Std Dev Un-Biased 1.06E-08 9.84E-09 8.95E-09 8.29E-09 7.36E-09 8.23E-09 9.16E-09Ps90%/90% (+KTL) Un-Biased -2.70E-07 -2.80E-07 -2.89E-07 -2.96E-07 -3.09E-07 -3.04E-07 -2.86E-07Ps90%/90% (-KTL) Un-Biased -3.28E-07 -3.34E-07 -3.38E-07 -3.42E-07 -3.49E-07 -3.49E-07 -3.36E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 97: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

97

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

-15

V #3

(A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.45. Plot of Positive Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 98: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

98

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.45. Raw data for Positive Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.94E-07 -3.00E-07 -3.06E-07 -3.12E-07 -3.18E-07 -3.08E-07 -3.04E-07879 -3.12E-07 -3.15E-07 -3.17E-07 -3.21E-07 -3.34E-07 -3.24E-07 -3.20E-07882 -2.98E-07 -3.06E-07 -3.12E-07 -3.16E-07 -3.24E-07 -3.14E-07 -3.08E-07883 -2.91E-07 -2.98E-07 -3.03E-07 -3.07E-07 -3.12E-07 -3.03E-07 -2.97E-07885 -3.08E-07 -3.16E-07 -3.21E-07 -3.31E-07 -3.33E-07 -3.23E-07 -3.17E-07886 -2.92E-07 -3.01E-07 -3.08E-07 -3.14E-07 -3.25E-07 -3.21E-07 -3.05E-07887 -3.12E-07 -3.18E-07 -3.22E-07 -3.27E-07 -3.34E-07 -3.33E-07 -3.21E-07891 -2.92E-07 -3.02E-07 -3.08E-07 -3.14E-07 -3.25E-07 -3.22E-07 -3.06E-07892 -2.94E-07 -3.02E-07 -3.08E-07 -3.14E-07 -3.24E-07 -3.21E-07 -3.05E-07895 -2.83E-07 -2.92E-07 -2.98E-07 -3.04E-07 -3.15E-07 -3.11E-07 -2.96E-07896 -2.94E-07 -3.07E-07 -3.07E-07 -3.06E-07 -3.06E-07 -3.06E-07 -3.06E-07

Biased StatisticsAverage Biased -3.01E-07 -3.07E-07 -3.12E-07 -3.17E-07 -3.24E-07 -3.14E-07 -3.09E-07Std Dev Biased 9.00E-09 8.08E-09 7.56E-09 9.24E-09 9.38E-09 9.27E-09 9.38E-09Ps90%/90% (+KTL) Biased -2.76E-07 -2.85E-07 -2.91E-07 -2.92E-07 -2.99E-07 -2.89E-07 -2.83E-07Ps90%/90% (-KTL) Biased -3.25E-07 -3.29E-07 -3.32E-07 -3.43E-07 -3.50E-07 -3.40E-07 -3.35E-07Un-Biased StatisticsAverage Un-Biased -2.95E-07 -3.03E-07 -3.09E-07 -3.15E-07 -3.25E-07 -3.22E-07 -3.07E-07Std Dev Un-Biased 1.07E-08 9.53E-09 8.62E-09 8.00E-09 6.84E-09 7.68E-09 8.97E-09Ps90%/90% (+KTL) Un-Biased -2.65E-07 -2.77E-07 -2.85E-07 -2.93E-07 -3.06E-07 -3.01E-07 -2.82E-07Ps90%/90% (-KTL) Un-Biased -3.24E-07 -3.29E-07 -3.32E-07 -3.37E-07 -3.43E-07 -3.43E-07 -3.31E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 99: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

99

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

+/-

15V,

VC

M=

-15

V #4

(A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.46. Plot of Positive Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 100: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

100

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.46. Raw data for Positive Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Positive Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.93E-07 -2.99E-07 -3.04E-07 -3.09E-07 -3.16E-07 -3.05E-07 -3.01E-07879 -3.03E-07 -3.08E-07 -3.14E-07 -3.18E-07 -3.33E-07 -3.18E-07 -3.13E-07882 -3.10E-07 -3.19E-07 -3.24E-07 -3.29E-07 -3.36E-07 -3.25E-07 -3.19E-07883 -3.13E-07 -3.21E-07 -3.26E-07 -3.29E-07 -3.34E-07 -3.25E-07 -3.19E-07885 -2.92E-07 -3.00E-07 -3.05E-07 -3.14E-07 -3.17E-07 -3.07E-07 -3.01E-07886 -2.95E-07 -3.04E-07 -3.11E-07 -3.17E-07 -3.28E-07 -3.25E-07 -3.08E-07887 -3.12E-07 -3.21E-07 -3.28E-07 -3.34E-07 -3.48E-07 -3.41E-07 -3.25E-07891 -3.12E-07 -3.21E-07 -3.26E-07 -3.32E-07 -3.41E-07 -3.38E-07 -3.23E-07892 -3.10E-07 -3.18E-07 -3.22E-07 -3.28E-07 -3.37E-07 -3.35E-07 -3.20E-07895 -3.09E-07 -3.17E-07 -3.24E-07 -3.30E-07 -3.41E-07 -3.37E-07 -3.21E-07896 -3.22E-07 -3.34E-07 -3.34E-07 -3.34E-07 -3.33E-07 -3.34E-07 -3.34E-07

Biased StatisticsAverage Biased -3.02E-07 -3.09E-07 -3.15E-07 -3.20E-07 -3.27E-07 -3.16E-07 -3.11E-07Std Dev Biased 9.82E-09 1.05E-08 1.03E-08 8.96E-09 9.84E-09 9.55E-09 9.14E-09Ps90%/90% (+KTL) Biased -2.75E-07 -2.81E-07 -2.86E-07 -2.95E-07 -3.00E-07 -2.90E-07 -2.86E-07Ps90%/90% (-KTL) Biased -3.29E-07 -3.38E-07 -3.43E-07 -3.45E-07 -3.54E-07 -3.42E-07 -3.36E-07Un-Biased StatisticsAverage Un-Biased -3.08E-07 -3.16E-07 -3.22E-07 -3.29E-07 -3.39E-07 -3.35E-07 -3.19E-07Std Dev Un-Biased 7.39E-09 7.11E-09 6.75E-09 6.64E-09 7.37E-09 6.01E-09 6.45E-09Ps90%/90% (+KTL) Un-Biased -2.87E-07 -2.97E-07 -3.04E-07 -3.10E-07 -3.19E-07 -3.19E-07 -3.02E-07Ps90%/90% (-KTL) Un-Biased -3.28E-07 -3.36E-07 -3.41E-07 -3.47E-07 -3.59E-07 -3.52E-07 -3.37E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 101: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

101

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= -1

5 V

#1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.47. Plot of Negative Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 102: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

102

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.47. Raw data for Negative Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.88E-07 -2.94E-07 -3.01E-07 -3.06E-07 -3.12E-07 -3.01E-07 -2.97E-07879 -3.01E-07 -3.07E-07 -3.12E-07 -3.17E-07 -3.34E-07 -3.18E-07 -3.12E-07882 -3.10E-07 -3.19E-07 -3.24E-07 -3.28E-07 -3.36E-07 -3.25E-07 -3.19E-07883 -3.10E-07 -3.18E-07 -3.23E-07 -3.27E-07 -3.33E-07 -3.23E-07 -3.17E-07885 -2.92E-07 -3.00E-07 -3.06E-07 -3.17E-07 -3.19E-07 -3.08E-07 -3.03E-07886 -2.92E-07 -3.01E-07 -3.08E-07 -3.14E-07 -3.25E-07 -3.22E-07 -3.05E-07887 -3.09E-07 -3.17E-07 -3.25E-07 -3.31E-07 -3.48E-07 -3.38E-07 -3.21E-07891 -3.13E-07 -3.21E-07 -3.27E-07 -3.33E-07 -3.49E-07 -3.40E-07 -3.24E-07892 -3.13E-07 -3.19E-07 -3.25E-07 -3.31E-07 -3.39E-07 -3.37E-07 -3.22E-07895 -3.09E-07 -3.18E-07 -3.26E-07 -3.32E-07 -3.49E-07 -3.39E-07 -3.22E-07896 -3.17E-07 -3.30E-07 -3.29E-07 -3.29E-07 -3.28E-07 -3.29E-07 -3.29E-07

Biased StatisticsAverage Biased -3.00E-07 -3.07E-07 -3.13E-07 -3.19E-07 -3.27E-07 -3.15E-07 -3.10E-07Std Dev Biased 1.01E-08 1.09E-08 1.03E-08 9.12E-09 1.06E-08 9.97E-09 9.31E-09Ps90%/90% (+KTL) Biased -2.73E-07 -2.78E-07 -2.85E-07 -2.94E-07 -2.98E-07 -2.88E-07 -2.84E-07Ps90%/90% (-KTL) Biased -3.28E-07 -3.37E-07 -3.41E-07 -3.44E-07 -3.56E-07 -3.42E-07 -3.35E-07Un-Biased StatisticsAverage Un-Biased -3.07E-07 -3.15E-07 -3.22E-07 -3.28E-07 -3.42E-07 -3.35E-07 -3.19E-07Std Dev Un-Biased 8.51E-09 8.14E-09 7.86E-09 8.01E-09 1.06E-08 7.60E-09 7.67E-09Ps90%/90% (+KTL) Un-Biased -2.84E-07 -2.93E-07 -3.00E-07 -3.06E-07 -3.13E-07 -3.14E-07 -2.98E-07Ps90%/90% (-KTL) Un-Biased -3.31E-07 -3.38E-07 -3.44E-07 -3.50E-07 -3.71E-07 -3.56E-07 -3.40E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 103: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

103

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= -1

5 V

#2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.48. Plot of Negative Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 104: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

104

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.48. Raw data for Negative Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.96E-07 -3.02E-07 -3.07E-07 -3.16E-07 -3.26E-07 -3.10E-07 -3.06E-07879 -3.11E-07 -3.14E-07 -3.16E-07 -3.20E-07 -3.35E-07 -3.24E-07 -3.20E-07882 -2.93E-07 -3.01E-07 -3.06E-07 -3.11E-07 -3.17E-07 -3.07E-07 -3.02E-07883 -2.95E-07 -3.01E-07 -3.06E-07 -3.10E-07 -3.15E-07 -3.12E-07 -3.00E-07885 -3.04E-07 -3.13E-07 -3.19E-07 -3.28E-07 -3.28E-07 -3.19E-07 -3.13E-07886 -2.96E-07 -3.05E-07 -3.12E-07 -3.19E-07 -3.30E-07 -3.26E-07 -3.10E-07887 -3.08E-07 -3.15E-07 -3.19E-07 -3.24E-07 -3.31E-07 -3.30E-07 -3.18E-07891 -2.97E-07 -3.06E-07 -3.13E-07 -3.18E-07 -3.28E-07 -3.26E-07 -3.10E-07892 -3.01E-07 -3.10E-07 -3.16E-07 -3.22E-07 -3.31E-07 -3.28E-07 -3.13E-07895 -2.87E-07 -2.95E-07 -3.02E-07 -3.08E-07 -3.19E-07 -3.15E-07 -3.00E-07896 -2.97E-07 -3.09E-07 -3.08E-07 -3.08E-07 -3.08E-07 -3.08E-07 -3.08E-07

Biased StatisticsAverage Biased -3.00E-07 -3.06E-07 -3.11E-07 -3.17E-07 -3.24E-07 -3.14E-07 -3.08E-07Std Dev Biased 7.62E-09 6.53E-09 6.04E-09 7.17E-09 7.96E-09 6.96E-09 8.35E-09Ps90%/90% (+KTL) Biased -2.79E-07 -2.88E-07 -2.94E-07 -2.97E-07 -3.03E-07 -2.95E-07 -2.85E-07Ps90%/90% (-KTL) Biased -3.21E-07 -3.24E-07 -3.27E-07 -3.36E-07 -3.46E-07 -3.33E-07 -3.31E-07Un-Biased StatisticsAverage Un-Biased -2.98E-07 -3.06E-07 -3.12E-07 -3.18E-07 -3.28E-07 -3.25E-07 -3.10E-07Std Dev Un-Biased 7.75E-09 7.13E-09 6.52E-09 6.18E-09 5.26E-09 5.76E-09 6.59E-09Ps90%/90% (+KTL) Un-Biased -2.77E-07 -2.87E-07 -2.94E-07 -3.01E-07 -3.13E-07 -3.09E-07 -2.92E-07Ps90%/90% (-KTL) Un-Biased -3.19E-07 -3.26E-07 -3.30E-07 -3.35E-07 -3.42E-07 -3.41E-07 -3.28E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 105: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

105

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= -1

5 V

#3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.49. Plot of Negative Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 106: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

106

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.49. Raw data for Negative Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.99E-07 -3.05E-07 -3.12E-07 -3.17E-07 -3.24E-07 -3.13E-07 -3.09E-07879 -3.07E-07 -3.10E-07 -3.12E-07 -3.16E-07 -3.31E-07 -3.20E-07 -3.16E-07882 -2.95E-07 -3.04E-07 -3.09E-07 -3.13E-07 -3.20E-07 -3.10E-07 -3.05E-07883 -2.93E-07 -3.00E-07 -3.05E-07 -3.09E-07 -3.14E-07 -3.05E-07 -2.99E-07885 -3.11E-07 -3.19E-07 -3.24E-07 -3.35E-07 -3.36E-07 -3.26E-07 -3.21E-07886 -2.93E-07 -3.01E-07 -3.08E-07 -3.14E-07 -3.25E-07 -3.22E-07 -3.06E-07887 -3.09E-07 -3.15E-07 -3.19E-07 -3.24E-07 -3.31E-07 -3.30E-07 -3.18E-07891 -2.94E-07 -3.03E-07 -3.09E-07 -3.16E-07 -3.25E-07 -3.23E-07 -3.08E-07892 -2.95E-07 -3.03E-07 -3.09E-07 -3.15E-07 -3.24E-07 -3.22E-07 -3.06E-07895 -2.83E-07 -2.91E-07 -2.98E-07 -3.05E-07 -3.16E-07 -3.12E-07 -2.97E-07896 -2.97E-07 -3.09E-07 -3.08E-07 -3.08E-07 -3.08E-07 -3.08E-07 -3.08E-07

Biased StatisticsAverage Biased -3.01E-07 -3.08E-07 -3.12E-07 -3.18E-07 -3.25E-07 -3.15E-07 -3.10E-07Std Dev Biased 7.83E-09 7.23E-09 7.35E-09 9.84E-09 8.83E-09 8.45E-09 8.61E-09Ps90%/90% (+KTL) Biased -2.80E-07 -2.88E-07 -2.92E-07 -2.91E-07 -3.01E-07 -2.92E-07 -2.86E-07Ps90%/90% (-KTL) Biased -3.23E-07 -3.27E-07 -3.32E-07 -3.45E-07 -3.49E-07 -3.38E-07 -3.34E-07Un-Biased StatisticsAverage Un-Biased -2.95E-07 -3.03E-07 -3.09E-07 -3.15E-07 -3.24E-07 -3.22E-07 -3.07E-07Std Dev Un-Biased 9.15E-09 8.30E-09 7.36E-09 6.77E-09 5.61E-09 6.42E-09 7.48E-09Ps90%/90% (+KTL) Un-Biased -2.70E-07 -2.80E-07 -2.88E-07 -2.96E-07 -3.09E-07 -3.04E-07 -2.86E-07Ps90%/90% (-KTL) Un-Biased -3.20E-07 -3.25E-07 -3.29E-07 -3.33E-07 -3.40E-07 -3.39E-07 -3.27E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 107: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

107

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ +

/- 15

V, V

CM

= -1

5 V

#4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.50. Plot of Negative Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 108: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

108

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.50. Raw data for Negative Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Negative Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.88E-07 -2.94E-07 -3.00E-07 -3.06E-07 -3.12E-07 -3.02E-07 -2.98E-07879 -2.99E-07 -3.04E-07 -3.10E-07 -3.15E-07 -3.31E-07 -3.15E-07 -3.10E-07882 -3.13E-07 -3.22E-07 -3.26E-07 -3.31E-07 -3.37E-07 -3.27E-07 -3.21E-07883 -3.10E-07 -3.17E-07 -3.21E-07 -3.27E-07 -3.31E-07 -3.22E-07 -3.16E-07885 -2.92E-07 -2.99E-07 -3.06E-07 -3.16E-07 -3.18E-07 -3.08E-07 -3.02E-07886 -2.94E-07 -3.02E-07 -3.10E-07 -3.16E-07 -3.27E-07 -3.24E-07 -3.07E-07887 -3.09E-07 -3.18E-07 -3.25E-07 -3.31E-07 -3.41E-07 -3.38E-07 -3.21E-07891 -3.10E-07 -3.18E-07 -3.24E-07 -3.29E-07 -3.38E-07 -3.36E-07 -3.20E-07892 -3.12E-07 -3.19E-07 -3.24E-07 -3.30E-07 -3.38E-07 -3.36E-07 -3.21E-07895 -3.04E-07 -3.12E-07 -3.20E-07 -3.25E-07 -3.35E-07 -3.32E-07 -3.16E-07896 -3.28E-07 -3.40E-07 -3.40E-07 -3.39E-07 -3.38E-07 -3.39E-07 -3.39E-07

Biased StatisticsAverage Biased -3.00E-07 -3.07E-07 -3.13E-07 -3.19E-07 -3.26E-07 -3.15E-07 -3.09E-07Std Dev Biased 1.07E-08 1.15E-08 1.07E-08 1.00E-08 1.04E-08 1.01E-08 9.68E-09Ps90%/90% (+KTL) Biased -2.71E-07 -2.76E-07 -2.83E-07 -2.91E-07 -2.97E-07 -2.87E-07 -2.83E-07Ps90%/90% (-KTL) Biased -3.30E-07 -3.39E-07 -3.42E-07 -3.46E-07 -3.54E-07 -3.43E-07 -3.36E-07Un-Biased StatisticsAverage Un-Biased -3.06E-07 -3.14E-07 -3.20E-07 -3.26E-07 -3.36E-07 -3.33E-07 -3.17E-07Std Dev Un-Biased 7.23E-09 6.94E-09 6.01E-09 6.10E-09 5.57E-09 5.69E-09 5.97E-09Ps90%/90% (+KTL) Un-Biased -2.86E-07 -2.95E-07 -3.04E-07 -3.09E-07 -3.21E-07 -3.17E-07 -3.01E-07Ps90%/90% (-KTL) Un-Biased -3.26E-07 -3.33E-07 -3.37E-07 -3.43E-07 -3.51E-07 -3.49E-07 -3.34E-07Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 109: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

109

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

3.00E+03

3.50E+03

4.00E+03

4.50E+03

5.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 1

0k, V

O=+

/- 14

.5 V

#1

(V/m

V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.51. Plot of Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #1 (V/mV) versus total dose. Thedata show some degradation with radiation, however it is not sufficient for any of the units-under-test toexceed specification. The solid diamonds are the average of the measured data points for the sample irradiatedunder electrical bias while the shaded diamonds are the average of the measured data points for the unitsirradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data pointsafter application of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 110: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

110

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.51. Raw data for Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #1 (V/mV)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #1 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.70E+03 3.43E+03 3.31E+03 3.59E+03 3.28E+03 3.31E+03 3.44E+03879 3.91E+03 4.02E+03 3.58E+03 3.65E+03 3.77E+03 4.21E+03 3.60E+03882 3.48E+03 3.67E+03 3.55E+03 3.43E+03 3.58E+03 3.47E+03 3.24E+03883 4.21E+03 4.16E+03 4.01E+03 3.96E+03 4.00E+03 3.94E+03 3.94E+03885 2.94E+03 3.59E+03 3.47E+03 3.54E+03 3.55E+03 3.46E+03 3.55E+03886 3.86E+03 3.84E+03 3.59E+03 3.44E+03 3.65E+03 3.40E+03 3.50E+03887 6.01E+03 5.68E+03 5.35E+03 6.21E+03 5.12E+03 5.66E+03 5.52E+03891 3.67E+03 3.63E+03 3.54E+03 3.56E+03 3.58E+03 3.51E+03 3.66E+03892 5.67E+03 5.42E+03 4.77E+03 5.14E+03 4.63E+03 5.22E+03 5.45E+03895 3.87E+03 3.57E+03 3.55E+03 3.51E+03 3.67E+03 3.85E+03 3.73E+03896 5.64E+03 6.19E+03 6.02E+03 5.93E+03 5.75E+03 6.13E+03 5.82E+03

Biased StatisticsAverage Biased 3.65E+03 3.77E+03 3.58E+03 3.63E+03 3.64E+03 3.68E+03 3.55E+03Std Dev Biased 4.80E+02 3.07E+02 2.63E+02 1.99E+02 2.70E+02 3.77E+02 2.55E+02Ps90%/90% (+KTL) Biased 4.96E+03 4.62E+03 4.31E+03 4.18E+03 4.38E+03 4.71E+03 4.25E+03Ps90%/90% (-KTL) Biased 2.33E+03 2.93E+03 2.86E+03 3.09E+03 2.90E+03 2.64E+03 2.85E+03Un-Biased StatisticsAverage Un-Biased 4.62E+03 4.43E+03 4.16E+03 4.37E+03 4.13E+03 4.33E+03 4.37E+03Std Dev Un-Biased 1.13E+03 1.03E+03 8.47E+02 1.25E+03 7.02E+02 1.04E+03 1.02E+03Ps90%/90% (+KTL) Un-Biased 7.70E+03 7.25E+03 6.48E+03 7.79E+03 6.05E+03 7.19E+03 7.17E+03Ps90%/90% (-KTL) Un-Biased 1.53E+03 1.60E+03 1.84E+03 9.55E+02 2.21E+03 1.47E+03 1.58E+03Specification MIN 1.00E+03 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 111: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

111

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

3.00E+03

3.50E+03

4.00E+03

4.50E+03

5.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 1

0k, V

O=+

/- 14

.5 V

#2

(V/m

V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.52. Plot of Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #2 (V/mV) versus total dose. Thedata show some degradation with radiation, however it is not sufficient for any of the units-under-test toexceed specification. The solid diamonds are the average of the measured data points for the sample irradiatedunder electrical bias while the shaded diamonds are the average of the measured data points for the unitsirradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data pointsafter application of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 112: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

112

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.52. Raw data for Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #2 (V/mV)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #2 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.89E+03 3.62E+03 3.44E+03 3.43E+03 3.41E+03 3.51E+03 3.47E+03879 3.95E+03 3.59E+03 3.64E+03 3.59E+03 3.53E+03 3.63E+03 3.56E+03882 3.90E+03 3.87E+03 3.87E+03 3.65E+03 3.61E+03 3.70E+03 3.65E+03883 5.74E+03 5.89E+03 5.08E+03 5.56E+03 4.72E+03 5.43E+03 5.25E+03885 5.95E+03 5.25E+03 4.91E+03 5.17E+03 5.06E+03 5.31E+03 5.26E+03886 3.42E+03 3.33E+03 3.16E+03 3.24E+03 3.27E+03 3.24E+03 3.21E+03887 5.99E+03 5.51E+03 5.70E+03 4.44E+03 5.59E+03 6.21E+03 6.14E+03891 3.63E+03 3.59E+03 3.37E+03 3.62E+03 3.24E+03 3.27E+03 3.59E+03892 3.38E+03 3.39E+03 3.12E+03 2.96E+03 3.13E+03 3.19E+03 3.08E+03895 3.70E+03 3.83E+03 3.97E+03 3.63E+03 3.37E+03 3.40E+03 3.60E+03896 6.64E+03 7.17E+03 7.02E+03 7.33E+03 7.20E+03 6.85E+03 6.49E+03

Biased StatisticsAverage Biased 4.69E+03 4.44E+03 4.19E+03 4.28E+03 4.06E+03 4.32E+03 4.24E+03Std Dev Biased 1.06E+03 1.06E+03 7.56E+02 1.00E+03 7.63E+02 9.65E+02 9.30E+02Ps90%/90% (+KTL) Biased 7.59E+03 7.35E+03 6.26E+03 7.03E+03 6.16E+03 6.96E+03 6.79E+03Ps90%/90% (-KTL) Biased 1.78E+03 1.54E+03 2.11E+03 1.53E+03 1.97E+03 1.67E+03 1.69E+03Un-Biased StatisticsAverage Un-Biased 4.02E+03 3.93E+03 3.86E+03 3.58E+03 3.72E+03 3.86E+03 3.92E+03Std Dev Un-Biased 1.10E+03 9.08E+02 1.08E+03 5.58E+02 1.05E+03 1.32E+03 1.26E+03Ps90%/90% (+KTL) Un-Biased 7.05E+03 6.42E+03 6.82E+03 5.11E+03 6.60E+03 7.47E+03 7.37E+03Ps90%/90% (-KTL) Un-Biased 9.94E+02 1.44E+03 9.07E+02 2.05E+03 8.43E+02 2.50E+02 4.77E+02Specification MIN 1.00E+03 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02Status FAIL PASS PASS PASS PASS FAIL FAIL

Total Dose (krad(Si))

Page 113: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

113

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

3.00E+03

3.50E+03

4.00E+03

4.50E+03

5.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 1

0k, V

O=+

/- 14

.5 V

#3

(V/m

V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.53. Plot of Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #3 (V/mV) versus total dose. Thedata show some degradation with radiation, however it is not sufficient for any of the units-under-test toexceed specification. The solid diamonds are the average of the measured data points for the sample irradiatedunder electrical bias while the shaded diamonds are the average of the measured data points for the unitsirradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data pointsafter application of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 114: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

114

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.53. Raw data for Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #3 (V/mV)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #3 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.22E+03 5.84E+03 5.40E+03 5.36E+03 5.31E+03 5.57E+03 5.68E+03879 3.58E+03 3.37E+03 3.43E+03 3.23E+03 3.32E+03 3.66E+03 3.44E+03882 3.95E+03 3.61E+03 3.71E+03 3.64E+03 3.64E+03 3.71E+03 3.66E+03883 3.79E+03 3.60E+03 3.44E+03 3.58E+03 3.32E+03 3.53E+03 3.50E+03885 3.68E+03 3.57E+03 3.35E+03 3.44E+03 3.21E+03 3.48E+03 3.44E+03886 5.31E+03 5.15E+03 4.57E+03 5.17E+03 4.77E+03 4.81E+03 5.27E+03887 3.74E+03 3.56E+03 3.67E+03 3.60E+03 3.74E+03 3.49E+03 3.67E+03891 3.52E+03 3.56E+03 3.45E+03 3.41E+03 3.18E+03 3.19E+03 3.40E+03892 5.42E+03 4.84E+03 4.88E+03 4.83E+03 5.43E+03 4.83E+03 5.13E+03895 3.67E+03 3.74E+03 3.38E+03 3.49E+03 3.22E+03 3.45E+03 3.49E+03896 3.66E+03 3.98E+03 3.95E+03 3.98E+03 3.91E+03 3.85E+03 3.92E+03

Biased StatisticsAverage Biased 4.24E+03 4.00E+03 3.87E+03 3.85E+03 3.76E+03 3.99E+03 3.94E+03Std Dev Biased 1.11E+03 1.04E+03 8.65E+02 8.60E+02 8.81E+02 8.88E+02 9.74E+02Ps90%/90% (+KTL) Biased 7.30E+03 6.84E+03 6.24E+03 6.21E+03 6.17E+03 6.43E+03 6.62E+03Ps90%/90% (-KTL) Biased 1.18E+03 1.16E+03 1.49E+03 1.49E+03 1.34E+03 1.55E+03 1.27E+03Un-Biased StatisticsAverage Un-Biased 4.33E+03 4.17E+03 3.99E+03 4.10E+03 4.06E+03 3.95E+03 4.19E+03Std Dev Un-Biased 9.45E+02 7.66E+02 6.88E+02 8.34E+02 9.96E+02 7.97E+02 9.28E+02Ps90%/90% (+KTL) Un-Biased 6.92E+03 6.27E+03 5.88E+03 6.39E+03 6.80E+03 6.14E+03 6.74E+03Ps90%/90% (-KTL) Un-Biased 1.74E+03 2.07E+03 2.10E+03 1.81E+03 1.33E+03 1.77E+03 1.64E+03Specification MIN 1.00E+03 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 115: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

115

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E+03

2.00E+03

3.00E+03

4.00E+03

5.00E+03

6.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 1

0k, V

O=+

/- 14

.5 V

#4

(V/m

V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.54. Plot of Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #4 (V/mV) versus total dose. Thedata show some degradation with radiation, however it is not sufficient for any of the units-under-test toexceed specification. The solid diamonds are the average of the measured data points for the sample irradiatedunder electrical bias while the shaded diamonds are the average of the measured data points for the unitsirradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data pointsafter application of the KTL statistics on the sample irradiated under electrical bias while the gray lines (solidand/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 116: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

116

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.54. Raw data for Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #4 (V/mV)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #4 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.83E+03 3.29E+03 3.42E+03 3.15E+03 3.18E+03 3.36E+03 3.33E+03879 4.13E+03 3.92E+03 3.96E+03 3.98E+03 3.70E+03 3.92E+03 3.99E+03882 4.28E+03 4.08E+03 4.25E+03 3.70E+03 3.88E+03 3.85E+03 3.91E+03883 6.18E+03 5.32E+03 5.38E+03 5.49E+03 4.78E+03 5.39E+03 5.64E+03885 6.40E+03 6.12E+03 6.01E+03 6.06E+03 5.73E+03 5.67E+03 6.14E+03886 3.99E+03 4.01E+03 4.02E+03 3.65E+03 3.46E+03 3.69E+03 3.65E+03887 4.87E+03 4.87E+03 4.45E+03 4.60E+03 4.95E+03 4.03E+03 4.60E+03891 4.65E+03 4.73E+03 4.20E+03 4.60E+03 4.44E+03 4.15E+03 4.63E+03892 6.36E+03 7.66E+03 5.67E+03 5.56E+03 5.26E+03 5.81E+03 6.02E+03895 5.15E+03 4.87E+03 5.25E+03 4.93E+03 4.59E+03 4.92E+03 4.94E+03896 5.66E+03 5.95E+03 6.05E+03 6.34E+03 5.96E+03 5.71E+03 5.48E+03

Biased StatisticsAverage Biased 4.96E+03 4.54E+03 4.61E+03 4.47E+03 4.25E+03 4.44E+03 4.60E+03Std Dev Biased 1.22E+03 1.15E+03 1.06E+03 1.24E+03 1.01E+03 1.03E+03 1.22E+03Ps90%/90% (+KTL) Biased 8.31E+03 7.69E+03 7.52E+03 7.87E+03 7.01E+03 7.25E+03 7.94E+03Ps90%/90% (-KTL) Biased 1.61E+03 1.40E+03 1.69E+03 1.08E+03 1.49E+03 1.62E+03 1.26E+03Un-Biased StatisticsAverage Un-Biased 5.00E+03 5.23E+03 4.72E+03 4.67E+03 4.54E+03 4.52E+03 4.77E+03Std Dev Un-Biased 8.73E+02 1.40E+03 7.10E+02 6.92E+02 6.85E+02 8.52E+02 8.49E+02Ps90%/90% (+KTL) Un-Biased 7.40E+03 9.08E+03 6.66E+03 6.57E+03 6.42E+03 6.85E+03 7.09E+03Ps90%/90% (-KTL) Un-Biased 2.61E+03 1.38E+03 2.77E+03 2.77E+03 2.66E+03 2.18E+03 2.44E+03Specification MIN 1.00E+03 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02 5.00E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 117: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

117

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E+02

-2.00E+02

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 2

k, V

O=+

/- 10

V #

1 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.55. Plot of Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #1 (V/mV) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 118: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

118

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.55. Raw data for Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #1 (V/mV) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #1 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.08E+02 8.78E+02 8.67E+02 8.63E+02 8.34E+02 8.52E+02 8.56E+02879 9.83E+02 9.51E+02 9.08E+02 9.92E+02 9.00E+02 9.06E+02 9.52E+02882 9.38E+02 9.11E+02 9.24E+02 8.98E+02 8.73E+02 8.73E+02 8.96E+02883 1.07E+03 1.05E+03 1.02E+03 1.02E+03 9.84E+02 9.99E+02 9.92E+02885 9.19E+02 9.52E+02 9.38E+02 9.41E+02 9.09E+02 9.28E+02 9.27E+02886 9.84E+02 1.01E+03 9.75E+02 9.74E+02 9.36E+02 9.16E+02 9.82E+02887 2.06E+03 2.04E+03 1.93E+03 1.94E+03 1.88E+03 1.83E+03 1.94E+03891 9.39E+02 9.26E+02 9.23E+02 9.12E+02 8.93E+02 8.87E+02 9.30E+02892 1.92E+03 1.91E+03 1.81E+03 1.77E+03 1.75E+03 1.70E+03 1.80E+03895 9.57E+02 9.43E+02 9.25E+02 9.09E+02 9.27E+02 9.15E+02 9.43E+02896 1.99E+03 2.08E+03 2.13E+03 2.14E+03 2.06E+03 2.11E+03 2.14E+03

Biased StatisticsAverage Biased 9.64E+02 9.48E+02 9.32E+02 9.42E+02 9.00E+02 9.12E+02 9.25E+02Std Dev Biased 6.68E+01 6.38E+01 5.66E+01 6.41E+01 5.53E+01 5.70E+01 5.20E+01Ps90%/90% (+KTL) Biased 1.15E+03 1.12E+03 1.09E+03 1.12E+03 1.05E+03 1.07E+03 1.07E+03Ps90%/90% (-KTL) Biased 7.81E+02 7.73E+02 7.76E+02 7.67E+02 7.48E+02 7.55E+02 7.82E+02Un-Biased StatisticsAverage Un-Biased 1.37E+03 1.36E+03 1.31E+03 1.30E+03 1.28E+03 1.25E+03 1.32E+03Std Dev Un-Biased 5.66E+02 5.57E+02 5.12E+02 5.09E+02 4.91E+02 4.75E+02 5.06E+02Ps90%/90% (+KTL) Un-Biased 2.93E+03 2.89E+03 2.72E+03 2.70E+03 2.62E+03 2.55E+03 2.71E+03Ps90%/90% (-KTL) Un-Biased -1.81E+02 -1.62E+02 -8.96E+01 -9.49E+01 -7.10E+01 -5.08E+01 -6.83E+01Specification MIN 5.00E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 119: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

119

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-6.00E+02

-4.00E+02

-2.00E+02

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 2

k, V

O=+

/- 10

V #

2 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.56. Plot of Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #2 (V/mV) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 120: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

120

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.56. Raw data for Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #2 (V/mV) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #2 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.34E+02 9.21E+02 8.89E+02 8.88E+02 8.65E+02 8.90E+02 9.00E+02879 9.72E+02 9.40E+02 9.27E+02 9.08E+02 9.35E+02 9.22E+02 9.37E+02882 1.02E+03 9.79E+02 9.94E+02 9.57E+02 9.54E+02 9.70E+02 9.70E+02883 1.96E+03 1.96E+03 1.85E+03 1.85E+03 1.79E+03 1.93E+03 1.88E+03885 1.98E+03 1.89E+03 1.82E+03 1.86E+03 1.80E+03 1.80E+03 1.82E+03886 8.68E+02 8.55E+02 8.40E+02 8.32E+02 8.02E+02 8.31E+02 8.37E+02887 2.13E+03 2.15E+03 2.09E+03 1.90E+03 1.90E+03 1.87E+03 1.98E+03891 9.56E+02 9.58E+02 9.50E+02 9.25E+02 9.19E+02 8.98E+02 9.19E+02892 8.53E+02 8.49E+02 8.26E+02 8.26E+02 8.16E+02 8.32E+02 8.29E+02895 9.36E+02 9.24E+02 8.95E+02 8.92E+02 8.91E+02 8.91E+02 9.05E+02896 2.39E+03 2.50E+03 2.48E+03 2.44E+03 2.47E+03 2.44E+03 2.44E+03

Biased StatisticsAverage Biased 1.37E+03 1.34E+03 1.30E+03 1.29E+03 1.27E+03 1.30E+03 1.30E+03Std Dev Biased 5.43E+02 5.38E+02 4.94E+02 5.14E+02 4.80E+02 5.15E+02 5.02E+02Ps90%/90% (+KTL) Biased 2.86E+03 2.82E+03 2.65E+03 2.70E+03 2.59E+03 2.71E+03 2.68E+03Ps90%/90% (-KTL) Biased ######## ######## ######## ######## ######## ######## ########Un-Biased StatisticsAverage Un-Biased 1.15E+03 1.15E+03 1.12E+03 1.08E+03 1.07E+03 1.07E+03 1.09E+03Std Dev Un-Biased 5.49E+02 5.63E+02 5.46E+02 4.63E+02 4.69E+02 4.53E+02 4.98E+02Ps90%/90% (+KTL) Un-Biased 2.65E+03 2.69E+03 2.62E+03 2.34E+03 2.35E+03 2.31E+03 2.46E+03Ps90%/90% (-KTL) Un-Biased ######## ######## ######## ######## ######## ######## ########Specification MIN 5.00E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 121: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

121

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E+03

-5.00E+02

0.00E+00

5.00E+02

1.00E+03

1.50E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 2

k, V

O=+

/- 10

V #

3 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.57. Plot of Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #3 (V/mV) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 122: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

122

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.57. Raw data for Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #3 (V/mV) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #3 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.36E+03 2.16E+03 2.04E+03 1.99E+03 2.01E+03 2.10E+03 2.11E+03879 9.71E+02 9.26E+02 9.19E+02 8.99E+02 9.07E+02 9.16E+02 9.21E+02882 1.03E+03 9.92E+02 9.82E+02 9.90E+02 9.57E+02 9.64E+02 9.75E+02883 9.57E+02 9.36E+02 9.15E+02 9.08E+02 8.65E+02 9.09E+02 8.94E+02885 9.41E+02 9.12E+02 9.04E+02 9.32E+02 8.76E+02 8.92E+02 9.01E+02886 2.03E+03 1.98E+03 1.82E+03 1.81E+03 1.70E+03 1.87E+03 1.92E+03887 9.70E+02 9.64E+02 9.39E+02 9.41E+02 9.28E+02 9.31E+02 9.24E+02891 9.46E+02 9.34E+02 9.13E+02 9.17E+02 8.67E+02 9.04E+02 9.44E+02892 1.96E+03 1.90E+03 1.87E+03 1.74E+03 1.81E+03 1.76E+03 1.84E+03895 9.42E+02 9.33E+02 9.16E+02 8.87E+02 8.67E+02 9.19E+02 9.23E+02896 9.96E+02 1.03E+03 1.03E+03 1.03E+03 1.02E+03 1.04E+03 1.03E+03

Biased StatisticsAverage Biased 1.25E+03 1.19E+03 1.15E+03 1.14E+03 1.12E+03 1.16E+03 1.16E+03Std Dev Biased 6.22E+02 5.47E+02 4.96E+02 4.72E+02 4.96E+02 5.27E+02 5.33E+02Ps90%/90% (+KTL) Biased 2.96E+03 2.69E+03 2.51E+03 2.44E+03 2.48E+03 2.60E+03 2.62E+03Ps90%/90% (-KTL) Biased -4.55E+02 -3.14E+02 -2.08E+02 -1.52E+02 -2.37E+02 -2.90E+02 -3.01E+02Un-Biased StatisticsAverage Un-Biased 1.37E+03 1.34E+03 1.29E+03 1.26E+03 1.24E+03 1.28E+03 1.31E+03Std Dev Un-Biased 5.71E+02 5.44E+02 5.06E+02 4.72E+02 4.78E+02 4.93E+02 5.21E+02Ps90%/90% (+KTL) Un-Biased 2.94E+03 2.83E+03 2.68E+03 2.55E+03 2.55E+03 2.63E+03 2.74E+03Ps90%/90% (-KTL) Un-Biased -1.97E+02 -1.52E+02 -9.47E+01 -3.47E+01 -7.67E+01 -7.42E+01 -1.18E+02Specification MIN 5.00E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 123: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

123

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E+02

-2.00E+02

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

1.80E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n R

L= 2

k, V

O=+

/- 10

V #

4 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.58. Plot of Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #4 (V/mV) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 124: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

124

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.58. Raw data for Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #4 (V/mV) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #4 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 8.99E+02 8.29E+02 8.49E+02 8.29E+02 8.29E+02 8.31E+02 8.47E+02879 1.02E+03 9.84E+02 9.67E+02 9.60E+02 9.59E+02 9.79E+02 9.76E+02882 1.55E+03 1.49E+03 1.44E+03 1.37E+03 1.37E+03 1.40E+03 1.37E+03883 2.15E+03 1.99E+03 1.92E+03 1.96E+03 1.83E+03 2.04E+03 1.94E+03885 2.31E+03 2.13E+03 2.10E+03 2.22E+03 1.99E+03 2.06E+03 2.09E+03886 9.81E+02 9.72E+02 9.62E+02 9.43E+02 9.36E+02 9.31E+02 9.47E+02887 1.74E+03 1.68E+03 1.71E+03 1.59E+03 1.54E+03 1.62E+03 1.65E+03891 1.33E+03 1.32E+03 1.26E+03 1.24E+03 1.24E+03 1.32E+03 1.31E+03892 2.22E+03 2.19E+03 2.08E+03 2.14E+03 1.91E+03 1.98E+03 2.06E+03895 1.40E+03 1.38E+03 1.34E+03 1.39E+03 1.26E+03 1.27E+03 1.35E+03896 2.02E+03 2.12E+03 2.05E+03 2.12E+03 2.11E+03 2.00E+03 2.09E+03

Biased StatisticsAverage Biased 1.59E+03 1.49E+03 1.45E+03 1.47E+03 1.40E+03 1.46E+03 1.45E+03Std Dev Biased 6.41E+02 5.82E+02 5.56E+02 6.09E+02 5.13E+02 5.75E+02 5.59E+02Ps90%/90% (+KTL) Biased 3.35E+03 3.08E+03 2.98E+03 3.14E+03 2.80E+03 3.04E+03 2.98E+03Ps90%/90% (-KTL) Biased ######## ######## ######## ######## ######## ######## ########Un-Biased StatisticsAverage Un-Biased 1.54E+03 1.51E+03 1.47E+03 1.46E+03 1.38E+03 1.42E+03 1.46E+03Std Dev Un-Biased 4.69E+02 4.55E+02 4.34E+02 4.48E+02 3.67E+02 3.96E+02 4.15E+02Ps90%/90% (+KTL) Un-Biased 2.82E+03 2.76E+03 2.66E+03 2.69E+03 2.38E+03 2.51E+03 2.60E+03Ps90%/90% (-KTL) Un-Biased 2.49E+02 2.61E+02 2.80E+02 2.30E+02 3.70E+02 3.39E+02 3.26E+02Specification MIN 5.00E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02 2.50E+02Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 125: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

125

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

+/-

15 V

, VC

M=+

/- 15

V

#1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.59. Plot of Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #1 (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 126: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

126

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.59. Raw data for Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #1(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #1 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.80E+01 9.81E+01 9.82E+01 9.82E+01 9.82E+01 9.83E+01 9.78E+01879 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02882 9.64E+01 9.64E+01 9.64E+01 9.63E+01 9.63E+01 9.65E+01 9.60E+01883 9.94E+01 9.95E+01 9.95E+01 9.95E+01 9.94E+01 9.96E+01 9.91E+01885 9.90E+01 9.91E+01 9.91E+01 9.88E+01 9.91E+01 9.92E+01 9.93E+01886 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.10E+02 1.10E+02 1.09E+02887 9.31E+01 9.31E+01 9.31E+01 9.31E+01 9.30E+01 9.31E+01 9.31E+01891 9.88E+01 9.87E+01 9.87E+01 9.87E+01 9.86E+01 9.86E+01 9.88E+01892 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.05E+02 1.06E+02 1.05E+02895 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02896 1.03E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02

Biased StatisticsAverage Biased 9.94E+01 9.95E+01 9.95E+01 9.94E+01 9.93E+01 9.95E+01 9.92E+01Std Dev Biased 3.03E+00 2.94E+00 2.93E+00 2.88E+00 2.65E+00 2.75E+00 2.95E+00Ps90%/90% (+KTL) Biased 1.08E+02 1.08E+02 1.08E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02Ps90%/90% (-KTL) Biased 9.11E+01 9.14E+01 9.14E+01 9.15E+01 9.20E+01 9.19E+01 9.11E+01Un-Biased StatisticsAverage Un-Biased 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02Std Dev Un-Biased 6.13E+00 6.27E+00 6.31E+00 6.28E+00 6.37E+00 6.34E+00 6.24E+00Ps90%/90% (+KTL) Un-Biased 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02Ps90%/90% (-KTL) Un-Biased 8.49E+01 8.46E+01 8.45E+01 8.45E+01 8.43E+01 8.44E+01 8.46E+01Specification MIN 9.00E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 127: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

127

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

1.30E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

+/-

15 V

, VC

M=+

/- 15

V

#2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.60. Plot of Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #2 (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 128: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

128

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.60. Raw data for Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #2(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #2 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.50E+01 9.49E+01 9.50E+01 9.51E+01 9.52E+01 9.49E+01 9.46E+01879 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.03E+02 1.03E+02 1.03E+02882 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.02E+02883 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.05E+02 1.03E+02885 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02886 1.21E+02 1.19E+02 1.18E+02 1.18E+02 1.17E+02 1.17E+02 1.22E+02887 9.78E+01 9.77E+01 9.76E+01 9.76E+01 9.74E+01 9.74E+01 9.75E+01891 1.13E+02 1.13E+02 1.12E+02 1.11E+02 1.11E+02 1.11E+02 1.12E+02892 1.28E+02 1.30E+02 1.32E+02 1.37E+02 1.39E+02 1.41E+02 1.48E+02895 1.08E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02896 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02

Biased StatisticsAverage Biased 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.01E+02 1.02E+02 1.01E+02Std Dev Biased 3.95E+00 3.84E+00 3.78E+00 3.68E+00 3.52E+00 3.92E+00 3.56E+00Ps90%/90% (+KTL) Biased 1.13E+02 1.12E+02 1.12E+02 1.12E+02 1.11E+02 1.12E+02 1.11E+02Ps90%/90% (-KTL) Biased 9.11E+01 9.12E+01 9.13E+01 9.14E+01 9.17E+01 9.09E+01 9.11E+01Un-Biased StatisticsAverage Un-Biased 1.13E+02 1.13E+02 1.13E+02 1.14E+02 1.14E+02 1.15E+02 1.17E+02Std Dev Un-Biased 1.17E+01 1.20E+01 1.27E+01 1.49E+01 1.55E+01 1.64E+01 1.92E+01Ps90%/90% (+KTL) Un-Biased 1.46E+02 1.46E+02 1.48E+02 1.55E+02 1.57E+02 1.60E+02 1.70E+02Ps90%/90% (-KTL) Un-Biased 8.15E+01 8.03E+01 7.86E+01 7.35E+01 7.18E+01 6.98E+01 6.49E+01Specification MIN 9.00E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 129: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

129

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

+/-

15 V

, VC

M=+

/- 15

V

#3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.61. Plot of Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #3 (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 130: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

130

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.61. Raw data for Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #3(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #3 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.08E+02 1.07E+02 1.08E+02879 1.01E+02 1.00E+02 1.00E+02 1.00E+02 9.98E+01 1.00E+02 9.96E+01882 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02883 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.02E+02885 1.00E+02 1.00E+02 1.01E+02 1.00E+02 1.01E+02 1.01E+02 9.95E+01886 9.89E+01 9.88E+01 9.88E+01 9.87E+01 9.87E+01 9.87E+01 9.87E+01887 1.20E+02 1.21E+02 1.23E+02 1.26E+02 1.31E+02 1.29E+02 1.19E+02891 9.73E+01 9.73E+01 9.73E+01 9.72E+01 9.72E+01 9.72E+01 9.72E+01892 9.99E+01 9.98E+01 9.97E+01 9.96E+01 9.94E+01 9.95E+01 9.95E+01895 1.07E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.07E+02896 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02

Biased StatisticsAverage Biased 1.03E+02 1.02E+02 1.03E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02Std Dev Biased 2.74E+00 2.92E+00 2.94E+00 3.00E+00 3.14E+00 3.01E+00 3.69E+00Ps90%/90% (+KTL) Biased 1.10E+02 1.10E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.12E+02Ps90%/90% (-KTL) Biased 9.50E+01 9.45E+01 9.45E+01 9.41E+01 9.38E+01 9.42E+01 9.19E+01Un-Biased StatisticsAverage Un-Biased 1.05E+02 1.05E+02 1.05E+02 1.06E+02 1.06E+02 1.06E+02 1.04E+02Std Dev Un-Biased 9.48E+00 9.87E+00 1.06E+01 1.20E+01 1.39E+01 1.34E+01 9.14E+00Ps90%/90% (+KTL) Un-Biased 1.31E+02 1.32E+02 1.34E+02 1.38E+02 1.45E+02 1.43E+02 1.29E+02Ps90%/90% (-KTL) Un-Biased 7.86E+01 7.77E+01 7.60E+01 7.28E+01 6.82E+01 6.95E+01 7.92E+01Specification MIN 9.00E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 131: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

131

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

+/-

15 V

, VC

M=+

/- 15

V

#4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.62. Plot of Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #4 (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 132: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

132

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.62. Raw data for Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #4(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #4 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.65E+01 9.64E+01 9.64E+01 9.64E+01 9.64E+01 9.65E+01 9.63E+01879 1.21E+02 1.19E+02 1.18E+02 1.18E+02 1.16E+02 1.17E+02 1.15E+02882 9.77E+01 9.75E+01 9.75E+01 9.74E+01 9.74E+01 9.74E+01 9.69E+01883 1.09E+02 1.09E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.06E+02885 1.11E+02 1.11E+02 1.11E+02 1.10E+02 1.10E+02 1.10E+02 1.09E+02886 1.19E+02 1.17E+02 1.16E+02 1.16E+02 1.15E+02 1.15E+02 1.17E+02887 1.00E+02 1.00E+02 9.98E+01 9.98E+01 9.98E+01 9.98E+01 9.95E+01891 1.14E+02 1.14E+02 1.13E+02 1.12E+02 1.11E+02 1.12E+02 1.14E+02892 1.11E+02 1.12E+02 1.12E+02 1.12E+02 1.13E+02 1.13E+02 1.12E+02895 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02896 1.30E+02 1.51E+02 1.53E+02 1.60E+02 1.52E+02 1.48E+02 1.54E+02

Biased StatisticsAverage Biased 1.07E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.05E+02Std Dev Biased 1.01E+01 9.46E+00 9.23E+00 9.07E+00 8.43E+00 8.71E+00 7.92E+00Ps90%/90% (+KTL) Biased 1.35E+02 1.32E+02 1.32E+02 1.31E+02 1.29E+02 1.30E+02 1.26E+02Ps90%/90% (-KTL) Biased 7.93E+01 8.05E+01 8.10E+01 8.12E+01 8.24E+01 8.19E+01 8.29E+01Un-Biased StatisticsAverage Un-Biased 1.09E+02 1.09E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02Std Dev Un-Biased 8.25E+00 7.85E+00 7.57E+00 7.33E+00 7.21E+00 7.29E+00 7.80E+00Ps90%/90% (+KTL) Un-Biased 1.32E+02 1.30E+02 1.29E+02 1.28E+02 1.28E+02 1.28E+02 1.30E+02Ps90%/90% (-KTL) Un-Biased 8.64E+01 8.72E+01 8.76E+01 8.81E+01 8.82E+01 8.81E+01 8.71E+01Specification MIN 9.00E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01 8.60E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 133: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

133

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

1-4

@ +

/- 15

V,

VC

M=+

/- 15

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.63. Plot of Common Mode Rejection Ratio Matching 1-4 @ +/- 15 V, VCM=+/- 15 V (dB) versustotal dose. The data show no significant change with radiation. The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 134: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

134

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.63. Raw data for Common Mode Rejection Ratio Matching 1-4 @ +/- 15 V,VCM=+/- 15 V (dB) versus total dose, including the statistical analysis, specification and thestatus of the testing (pass/fail).

Common Mode Rejection Ratio Matching 1-4 @ +/- 15 V, VCM=+/- 15 V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.13E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.12E+02879 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.07E+02882 1.13E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.16E+02 1.16E+02883 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.04E+02 1.04E+02 1.04E+02885 1.01E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.03E+02886 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02887 9.84E+01 9.84E+01 9.84E+01 9.84E+01 9.83E+01 9.84E+01 9.87E+01891 1.00E+02 1.00E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.00E+02892 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.03E+02 1.02E+02895 1.19E+02 1.18E+02 1.18E+02 1.17E+02 1.16E+02 1.17E+02 1.21E+02896 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02

Biased StatisticsAverage Biased 1.07E+02 1.08E+02 1.08E+02 1.07E+02 1.07E+02 1.08E+02 1.08E+02Std Dev Biased 5.44E+00 5.62E+00 5.54E+00 5.43E+00 5.29E+00 5.82E+00 5.52E+00Ps90%/90% (+KTL) Biased 1.22E+02 1.23E+02 1.23E+02 1.22E+02 1.22E+02 1.24E+02 1.24E+02Ps90%/90% (-KTL) Biased 9.23E+01 9.21E+01 9.23E+01 9.25E+01 9.29E+01 9.18E+01 9.33E+01Un-Biased StatisticsAverage Un-Biased 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.06E+02Std Dev Un-Biased 8.15E+00 7.81E+00 7.56E+00 7.37E+00 7.07E+00 7.34E+00 8.95E+00Ps90%/90% (+KTL) Un-Biased 1.28E+02 1.27E+02 1.26E+02 1.25E+02 1.24E+02 1.25E+02 1.30E+02Ps90%/90% (-KTL) Un-Biased 8.28E+01 8.37E+01 8.43E+01 8.47E+01 8.54E+01 8.48E+01 8.11E+01Specification MIN 8.40E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01Status FAIL PASS PASS PASS PASS PASS FAIL

Total Dose (krad(Si))

Page 135: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

135

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

2-3

@ +

/- 15

V,

VC

M=+

/- 15

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.64. Plot of Common Mode Rejection Ratio Matching 2-3 @ +/- 15 V, VCM=+/- 15 V (dB) versustotal dose. The data show no significant change with radiation. The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 136: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

136

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.64. Raw data for Common Mode Rejection Ratio Matching 2-3 @ +/- 15 V,VCM=+/- 15 V (dB) versus total dose, including the statistical analysis, specification and thestatus of the testing (pass/fail).

Common Mode Rejection Ratio Matching 2-3 @ +/- 15 V, VCM=+/- 15 V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.30E+01 9.31E+01 9.31E+01 9.32E+01 9.33E+01 9.31E+01 9.30E+01879 1.11E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02882 1.15E+02 1.15E+02 1.17E+02 1.17E+02 1.18E+02 1.17E+02 1.17E+02883 1.21E+02 1.21E+02 1.22E+02 1.21E+02 1.20E+02 1.16E+02 1.19E+02885 1.13E+02 1.14E+02 1.15E+02 1.15E+02 1.17E+02 1.16E+02 1.13E+02886 9.97E+01 9.97E+01 9.98E+01 9.97E+01 9.98E+01 9.99E+01 9.93E+01887 9.72E+01 9.71E+01 9.72E+01 9.72E+01 9.73E+01 9.72E+01 9.68E+01891 9.88E+01 9.90E+01 9.90E+01 9.91E+01 9.92E+01 9.92E+01 9.89E+01892 9.95E+01 9.95E+01 9.95E+01 9.95E+01 9.93E+01 9.94E+01 9.95E+01895 1.27E+02 1.25E+02 1.26E+02 1.27E+02 1.29E+02 1.27E+02 1.31E+02896 1.08E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02

Biased StatisticsAverage Biased 1.10E+02 1.11E+02 1.11E+02 1.11E+02 1.12E+02 1.10E+02 1.10E+02Std Dev Biased 1.04E+01 1.05E+01 1.11E+01 1.07E+01 1.10E+01 1.01E+01 1.03E+01Ps90%/90% (+KTL) Biased 1.39E+02 1.40E+02 1.42E+02 1.41E+02 1.42E+02 1.38E+02 1.38E+02Ps90%/90% (-KTL) Biased 8.18E+01 8.17E+01 8.10E+01 8.16E+01 8.15E+01 8.27E+01 8.21E+01Un-Biased StatisticsAverage Un-Biased 1.04E+02 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02Std Dev Un-Biased 1.25E+01 1.19E+01 1.23E+01 1.27E+01 1.35E+01 1.26E+01 1.43E+01Ps90%/90% (+KTL) Un-Biased 1.39E+02 1.37E+02 1.38E+02 1.39E+02 1.42E+02 1.39E+02 1.44E+02Ps90%/90% (-KTL) Un-Biased 7.02E+01 7.14E+01 7.07E+01 6.98E+01 6.79E+01 7.00E+01 6.58E+01Specification MIN 8.40E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 137: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

137

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

+/-

2 V

to +

/- 16

V #

1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.65. Plot of Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #1 (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 138: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

138

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.65. Raw data for Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #1 (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #1 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.10E+02 1.09E+02 1.10E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02879 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02882 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02883 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02885 1.15E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.15E+02886 1.15E+02 1.15E+02 1.15E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02887 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02891 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02892 1.25E+02 1.25E+02 1.25E+02 1.26E+02 1.25E+02 1.25E+02 1.25E+02895 1.15E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02896 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02

Biased StatisticsAverage Biased 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02Std Dev Biased 5.12E+00 4.96E+00 4.90E+00 4.91E+00 4.90E+00 4.96E+00 4.99E+00Ps90%/90% (+KTL) Biased 1.22E+02 1.22E+02 1.22E+02 1.22E+02 1.21E+02 1.22E+02 1.22E+02Ps90%/90% (-KTL) Biased 9.42E+01 9.45E+01 9.47E+01 9.47E+01 9.46E+01 9.45E+01 9.44E+01Un-Biased StatisticsAverage Un-Biased 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02Std Dev Un-Biased 5.82E+00 5.85E+00 5.95E+00 6.10E+00 5.58E+00 5.65E+00 5.76E+00Ps90%/90% (+KTL) Un-Biased 1.32E+02 1.32E+02 1.32E+02 1.33E+02 1.31E+02 1.32E+02 1.32E+02Ps90%/90% (-KTL) Un-Biased 9.99E+01 9.99E+01 9.98E+01 9.95E+01 1.01E+02 1.01E+02 1.00E+02Specification MIN 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 139: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

139

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

+/-

2 V

to +

/- 16

V #

2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.66. Plot of Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #2 (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 140: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

140

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.66. Raw data for Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #2 (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #2 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02879 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02882 1.03E+02 1.03E+02 1.03E+02 1.04E+02 1.03E+02 1.03E+02 1.03E+02883 1.31E+02 1.29E+02 1.29E+02 1.28E+02 1.27E+02 1.28E+02 1.27E+02885 1.24E+02 1.25E+02 1.25E+02 1.25E+02 1.25E+02 1.25E+02 1.25E+02886 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1.19E+02887 1.04E+02 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.05E+02 1.04E+02891 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.04E+02892 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.14E+02 1.14E+02 1.13E+02895 1.14E+02 1.14E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02896 1.03E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02

Biased StatisticsAverage Biased 1.14E+02 1.14E+02 1.14E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02Std Dev Biased 1.31E+01 1.26E+01 1.24E+01 1.21E+01 1.20E+01 1.21E+01 1.20E+01Ps90%/90% (+KTL) Biased 1.50E+02 1.48E+02 1.48E+02 1.47E+02 1.46E+02 1.47E+02 1.46E+02Ps90%/90% (-KTL) Biased 7.80E+01 7.90E+01 7.94E+01 8.02E+01 8.02E+01 8.00E+01 8.02E+01Un-Biased StatisticsAverage Un-Biased 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02Std Dev Un-Biased 6.60E+00 6.57E+00 6.50E+00 6.40E+00 6.34E+00 6.32E+00 6.45E+00Ps90%/90% (+KTL) Un-Biased 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02Ps90%/90% (-KTL) Un-Biased 9.30E+01 9.31E+01 9.34E+01 9.37E+01 9.39E+01 9.39E+01 9.34E+01Specification MIN 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 141: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

141

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

+/-

2 V

to +

/- 16

V #

3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.67. Plot of Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #3 (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 142: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

142

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.67. Raw data for Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #3 (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #3 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02879 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02882 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02883 1.20E+02 1.21E+02 1.21E+02 1.22E+02 1.22E+02 1.22E+02 1.21E+02885 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02886 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02887 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02891 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02892 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02895 1.26E+02 1.28E+02 1.27E+02 1.27E+02 1.29E+02 1.30E+02 1.29E+02896 1.12E+02 1.13E+02 1.12E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02

Biased StatisticsAverage Biased 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02Std Dev Biased 9.37E+00 9.52E+00 9.46E+00 9.51E+00 9.60E+00 9.63E+00 9.55E+00Ps90%/90% (+KTL) Biased 1.40E+02 1.40E+02 1.40E+02 1.40E+02 1.41E+02 1.41E+02 1.41E+02Ps90%/90% (-KTL) Biased 8.82E+01 8.80E+01 8.82E+01 8.83E+01 8.82E+01 8.80E+01 8.82E+01Un-Biased StatisticsAverage Un-Biased 1.13E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02Std Dev Un-Biased 9.58E+00 1.05E+01 9.98E+00 1.01E+01 1.06E+01 1.10E+01 1.07E+01Ps90%/90% (+KTL) Un-Biased 1.40E+02 1.43E+02 1.41E+02 1.41E+02 1.43E+02 1.45E+02 1.43E+02Ps90%/90% (-KTL) Un-Biased 8.71E+01 8.52E+01 8.63E+01 8.61E+01 8.50E+01 8.41E+01 8.48E+01Specification MIN 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 143: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

143

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

+/-

2 V

to +

/- 16

V #

4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.68. Plot of Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #4 (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 144: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

144

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.68. Raw data for Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #4 (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #4 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.17E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02879 9.82E+01 9.82E+01 9.83E+01 9.83E+01 9.83E+01 9.82E+01 9.82E+01882 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02883 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02885 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02886 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02887 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.14E+02 1.14E+02 1.14E+02891 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02892 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02895 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02896 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02

Biased StatisticsAverage Biased 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02Std Dev Biased 7.65E+00 7.63E+00 7.61E+00 7.56E+00 7.63E+00 7.60E+00 7.61E+00Ps90%/90% (+KTL) Biased 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02 1.29E+02Ps90%/90% (-KTL) Biased 8.72E+01 8.71E+01 8.72E+01 8.73E+01 8.71E+01 8.71E+01 8.71E+01Un-Biased StatisticsAverage Un-Biased 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02Std Dev Un-Biased 4.90E+00 4.69E+00 4.71E+00 4.68E+00 4.55E+00 4.48E+00 4.61E+00Ps90%/90% (+KTL) Un-Biased 1.21E+02 1.21E+02 1.21E+02 1.21E+02 1.20E+02 1.20E+02 1.20E+02Ps90%/90% (-KTL) Un-Biased 9.46E+01 9.50E+01 9.51E+01 9.52E+01 9.54E+01 9.56E+01 9.52E+01Specification MIN 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01 9.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 145: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

145

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

1.30E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io M

atch

ing

1-4

@ +

/- 2

V to

+/

- 16

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.69. Plot of Power Supply Rejection Ratio Matching 1-4 @ +/- 2 V to +/- 16 V (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 146: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

146

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.69. Raw data for Power Supply Rejection Ratio Matching 1-4 @ +/- 2 V to +/- 16 V(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Power Supply Rejection Ratio Matching 1-4 @ +/- 2 V to +/- 16 V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02879 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02882 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.00E+02 1.00E+02 1.00E+02883 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02885 1.52E+02 1.38E+02 1.36E+02 1.39E+02 1.36E+02 1.37E+02 1.39E+02886 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02887 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.08E+02 1.08E+02891 1.17E+02 1.17E+02 1.18E+02 1.18E+02 1.18E+02 1.17E+02 1.17E+02892 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02895 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02896 1.28E+02 1.29E+02 1.30E+02 1.29E+02 1.30E+02 1.30E+02 1.31E+02

Biased StatisticsAverage Biased 1.18E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02Std Dev Biased 2.01E+01 1.42E+01 1.34E+01 1.44E+01 1.33E+01 1.39E+01 1.47E+01Ps90%/90% (+KTL) Biased 1.73E+02 1.54E+02 1.52E+02 1.55E+02 1.51E+02 1.53E+02 1.56E+02Ps90%/90% (-KTL) Biased 6.31E+01 7.64E+01 7.83E+01 7.60E+01 7.82E+01 7.67E+01 7.51E+01Un-Biased StatisticsAverage Un-Biased 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02Std Dev Un-Biased 5.38E+00 5.41E+00 5.51E+00 5.49E+00 5.51E+00 5.41E+00 5.44E+00Ps90%/90% (+KTL) Un-Biased 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02Ps90%/90% (-KTL) Un-Biased 9.61E+01 9.58E+01 9.58E+01 9.58E+01 9.57E+01 9.59E+01 9.57E+01Specification MIN 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 147: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

147

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io M

atch

ing

2-3

@ +

/- 2

V to

+/

- 16

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.70. Plot of Power Supply Rejection Ratio Matching 2-3 @ +/- 2 V to +/- 16 V (dB) versus total dose.The data show no significant change with radiation. The solid diamonds are the average of the measured datapoints for the sample irradiated under electrical bias while the shaded diamonds are the average of themeasured data points for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed)are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 148: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

148

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.70. Raw data for Power Supply Rejection Ratio Matching 2-3 @ +/- 2 V to +/- 16 V(dB) versus total dose, including the statistical analysis, specification and the status of thetesting (pass/fail).

Power Supply Rejection Ratio Matching 2-3 @ +/- 2 V to +/- 16 V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.10E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02879 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02882 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02883 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02885 1.19E+02 1.19E+02 1.20E+02 1.19E+02 1.20E+02 1.19E+02 1.20E+02886 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02887 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02891 1.12E+02 1.12E+02 1.12E+02 1.12E+02 1.12E+02 1.12E+02 1.12E+02892 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02895 1.17E+02 1.16E+02 1.17E+02 1.17E+02 1.17E+02 1.16E+02 1.16E+02896 1.07E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02

Biased StatisticsAverage Biased 1.12E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02Std Dev Biased 5.51E+00 5.74E+00 5.73E+00 5.70E+00 5.83E+00 5.86E+00 5.77E+00Ps90%/90% (+KTL) Biased 1.28E+02 1.28E+02 1.28E+02 1.28E+02 1.29E+02 1.29E+02 1.28E+02Ps90%/90% (-KTL) Biased 9.73E+01 9.68E+01 9.69E+01 9.70E+01 9.66E+01 9.65E+01 9.67E+01Un-Biased StatisticsAverage Un-Biased 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02Std Dev Un-Biased 2.68E+00 2.40E+00 2.55E+00 2.55E+00 2.33E+00 2.17E+00 2.32E+00Ps90%/90% (+KTL) Un-Biased 1.21E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.19E+02 1.20E+02Ps90%/90% (-KTL) Un-Biased 1.06E+02 1.07E+02 1.06E+02 1.06E+02 1.07E+02 1.07E+02 1.07E+02Specification MIN 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01 8.30E+01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 149: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

149

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0 m

A @

+/-

15 V

#1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.71. Plot of Output Voltage Swing High IL= 0 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 150: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

150

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.71. Raw data for Output Voltage Swing High IL= 0 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 0 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.49E-03 5.57E-03 5.58E-03 5.56E-03 5.72E-03 5.62E-03 5.69E-03879 5.61E-03 5.62E-03 5.68E-03 5.76E-03 5.72E-03 5.80E-03 5.79E-03882 5.47E-03 5.53E-03 5.63E-03 5.71E-03 5.60E-03 5.55E-03 5.61E-03883 5.64E-03 5.60E-03 5.78E-03 5.63E-03 5.69E-03 5.77E-03 5.84E-03885 5.56E-03 5.69E-03 5.73E-03 5.73E-03 5.84E-03 5.63E-03 5.84E-03886 5.47E-03 5.48E-03 5.66E-03 5.56E-03 5.72E-03 5.65E-03 5.66E-03887 5.44E-03 5.64E-03 5.51E-03 5.70E-03 5.74E-03 5.63E-03 5.64E-03891 5.52E-03 5.62E-03 5.61E-03 5.65E-03 5.76E-03 5.82E-03 5.59E-03892 5.35E-03 5.32E-03 5.51E-03 5.58E-03 5.64E-03 5.77E-03 5.46E-03895 5.62E-03 5.67E-03 5.59E-03 5.85E-03 5.89E-03 5.85E-03 5.84E-03896 5.93E-03 5.79E-03 5.78E-03 5.93E-03 5.70E-03 5.87E-03 5.88E-03

Biased StatisticsAverage Biased 5.55E-03 5.60E-03 5.68E-03 5.68E-03 5.71E-03 5.67E-03 5.75E-03Std Dev Biased 7.37E-05 5.97E-05 7.91E-05 8.17E-05 8.59E-05 1.06E-04 1.01E-04Ps90%/90% (+KTL) Biased 5.76E-03 5.77E-03 5.90E-03 5.90E-03 5.95E-03 5.97E-03 6.03E-03Ps90%/90% (-KTL) Biased 5.35E-03 5.44E-03 5.46E-03 5.45E-03 5.48E-03 5.38E-03 5.48E-03Un-Biased StatisticsAverage Un-Biased 5.48E-03 5.55E-03 5.58E-03 5.67E-03 5.75E-03 5.74E-03 5.64E-03Std Dev Un-Biased 9.97E-05 1.46E-04 6.54E-05 1.16E-04 9.06E-05 9.94E-05 1.37E-04Ps90%/90% (+KTL) Un-Biased 5.75E-03 5.95E-03 5.76E-03 5.99E-03 6.00E-03 6.02E-03 6.01E-03Ps90%/90% (-KTL) Un-Biased 5.21E-03 5.15E-03 5.40E-03 5.35E-03 5.50E-03 5.47E-03 5.26E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 151: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

151

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0 m

A @

+/-

15 V

#2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.72. Plot of Output Voltage Swing High IL= 0 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 152: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

152

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.72. Raw data for Output Voltage Swing High IL= 0 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 0 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.52E-03 5.79E-03 5.68E-03 5.78E-03 5.79E-03 5.78E-03 5.68E-03879 5.44E-03 5.23E-03 5.41E-03 5.55E-03 5.47E-03 5.40E-03 5.51E-03882 5.51E-03 5.55E-03 5.54E-03 5.58E-03 5.77E-03 5.56E-03 5.78E-03883 5.49E-03 5.79E-03 5.68E-03 5.71E-03 5.86E-03 5.92E-03 5.79E-03885 6.06E-03 6.14E-03 6.05E-03 6.10E-03 6.29E-03 6.31E-03 6.06E-03886 5.39E-03 5.47E-03 5.58E-03 5.56E-03 5.62E-03 5.56E-03 5.54E-03887 5.25E-03 5.26E-03 5.36E-03 5.46E-03 5.70E-03 5.62E-03 5.47E-03891 5.84E-03 5.85E-03 5.91E-03 5.98E-03 6.04E-03 6.04E-03 5.96E-03892 5.35E-03 5.42E-03 5.38E-03 5.46E-03 5.69E-03 5.55E-03 5.47E-03895 5.39E-03 5.48E-03 5.63E-03 5.46E-03 5.62E-03 5.50E-03 5.51E-03896 5.74E-03 5.58E-03 5.53E-03 5.60E-03 5.55E-03 5.48E-03 5.57E-03

Biased StatisticsAverage Biased 5.60E-03 5.70E-03 5.67E-03 5.74E-03 5.84E-03 5.79E-03 5.76E-03Std Dev Biased 2.57E-04 3.37E-04 2.39E-04 2.20E-04 2.95E-04 3.51E-04 2.00E-04Ps90%/90% (+KTL) Biased 6.31E-03 6.62E-03 6.33E-03 6.35E-03 6.64E-03 6.76E-03 6.31E-03Ps90%/90% (-KTL) Biased 4.90E-03 4.78E-03 5.02E-03 5.14E-03 5.03E-03 4.83E-03 5.22E-03Un-Biased StatisticsAverage Un-Biased 5.44E-03 5.50E-03 5.57E-03 5.58E-03 5.73E-03 5.65E-03 5.59E-03Std Dev Un-Biased 2.29E-04 2.17E-04 2.23E-04 2.26E-04 1.75E-04 2.20E-04 2.09E-04Ps90%/90% (+KTL) Un-Biased 6.07E-03 6.09E-03 6.18E-03 6.20E-03 6.21E-03 6.26E-03 6.16E-03Ps90%/90% (-KTL) Un-Biased 4.82E-03 4.90E-03 4.96E-03 4.97E-03 5.25E-03 5.05E-03 5.02E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 153: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

153

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0 m

A @

+/-

15 V

#3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.73. Plot of Output Voltage Swing High IL= 0 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 154: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

154

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.73. Raw data for Output Voltage Swing High IL= 0 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 0 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.56E-03 5.52E-03 5.70E-03 5.75E-03 5.82E-03 5.70E-03 5.64E-03879 5.32E-03 5.33E-03 5.44E-03 5.46E-03 5.62E-03 5.40E-03 5.61E-03882 5.49E-03 5.60E-03 5.65E-03 5.76E-03 5.74E-03 5.63E-03 5.73E-03883 5.74E-03 5.60E-03 5.73E-03 5.70E-03 5.92E-03 5.72E-03 5.83E-03885 5.41E-03 5.60E-03 5.70E-03 5.55E-03 5.82E-03 5.67E-03 5.61E-03886 5.96E-03 5.99E-03 6.07E-03 6.17E-03 6.29E-03 6.10E-03 6.15E-03887 5.12E-03 5.38E-03 5.34E-03 5.53E-03 5.47E-03 5.48E-03 5.46E-03891 5.57E-03 5.64E-03 5.73E-03 5.88E-03 5.79E-03 5.83E-03 5.71E-03892 5.30E-03 5.57E-03 5.58E-03 5.71E-03 5.70E-03 5.56E-03 5.61E-03895 5.46E-03 5.53E-03 5.58E-03 5.73E-03 5.76E-03 5.83E-03 5.56E-03896 5.86E-03 5.57E-03 5.59E-03 5.58E-03 5.55E-03 5.63E-03 5.59E-03

Biased StatisticsAverage Biased 5.50E-03 5.53E-03 5.64E-03 5.64E-03 5.78E-03 5.62E-03 5.68E-03Std Dev Biased 1.59E-04 1.17E-04 1.18E-04 1.33E-04 1.12E-04 1.30E-04 9.53E-05Ps90%/90% (+KTL) Biased 5.94E-03 5.85E-03 5.97E-03 6.01E-03 6.09E-03 5.98E-03 5.95E-03Ps90%/90% (-KTL) Biased 5.07E-03 5.21E-03 5.32E-03 5.28E-03 5.48E-03 5.27E-03 5.42E-03Un-Biased StatisticsAverage Un-Biased 5.48E-03 5.62E-03 5.66E-03 5.80E-03 5.80E-03 5.76E-03 5.70E-03Std Dev Un-Biased 3.17E-04 2.27E-04 2.68E-04 2.39E-04 3.00E-04 2.47E-04 2.68E-04Ps90%/90% (+KTL) Un-Biased 6.35E-03 6.24E-03 6.40E-03 6.46E-03 6.63E-03 6.44E-03 6.43E-03Ps90%/90% (-KTL) Un-Biased 4.61E-03 5.00E-03 4.92E-03 5.15E-03 4.98E-03 5.08E-03 4.96E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 155: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

155

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0 m

A @

+/-

15 V

#4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.74. Plot of Output Voltage Swing High IL= 0 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 156: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

156

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.74. Raw data for Output Voltage Swing High IL= 0 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 0 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.54E-03 5.58E-03 5.73E-03 5.73E-03 5.92E-03 5.65E-03 5.73E-03879 5.62E-03 5.65E-03 5.75E-03 5.68E-03 5.65E-03 5.70E-03 5.79E-03882 5.54E-03 5.48E-03 5.63E-03 5.60E-03 5.60E-03 5.55E-03 5.64E-03883 5.66E-03 5.67E-03 5.71E-03 5.73E-03 5.70E-03 5.82E-03 5.84E-03885 5.52E-03 5.58E-03 5.66E-03 5.63E-03 5.72E-03 5.70E-03 5.61E-03886 5.47E-03 5.57E-03 5.70E-03 5.60E-03 5.72E-03 5.80E-03 5.51E-03887 5.35E-03 5.47E-03 5.59E-03 5.61E-03 5.77E-03 5.67E-03 5.69E-03891 5.46E-03 5.74E-03 5.56E-03 5.71E-03 5.70E-03 5.63E-03 5.71E-03892 5.42E-03 5.64E-03 5.56E-03 5.76E-03 5.82E-03 5.68E-03 5.57E-03895 5.73E-03 5.69E-03 5.81E-03 5.75E-03 5.92E-03 5.88E-03 5.69E-03896 5.89E-03 5.74E-03 5.85E-03 5.80E-03 5.89E-03 5.83E-03 5.86E-03

Biased StatisticsAverage Biased 5.58E-03 5.59E-03 5.70E-03 5.67E-03 5.72E-03 5.68E-03 5.72E-03Std Dev Biased 6.07E-05 7.46E-05 4.98E-05 5.86E-05 1.22E-04 9.76E-05 9.73E-05Ps90%/90% (+KTL) Biased 5.74E-03 5.80E-03 5.83E-03 5.83E-03 6.05E-03 5.95E-03 5.99E-03Ps90%/90% (-KTL) Biased 5.41E-03 5.39E-03 5.56E-03 5.51E-03 5.38E-03 5.42E-03 5.46E-03Un-Biased StatisticsAverage Un-Biased 5.49E-03 5.62E-03 5.64E-03 5.69E-03 5.79E-03 5.73E-03 5.63E-03Std Dev Un-Biased 1.44E-04 1.06E-04 1.09E-04 7.64E-05 8.82E-05 1.04E-04 8.88E-05Ps90%/90% (+KTL) Un-Biased 5.88E-03 5.91E-03 5.94E-03 5.90E-03 6.03E-03 6.02E-03 5.88E-03Ps90%/90% (-KTL) Un-Biased 5.09E-03 5.33E-03 5.34E-03 5.48E-03 5.54E-03 5.45E-03 5.39E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 157: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

157

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1 m

A @

+/-

15 V

#1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.75. Plot of Output Voltage Swing High IL= 1 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 158: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

158

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.75. Raw data for Output Voltage Swing High IL= 1 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 1 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.31E-02 7.44E-02 7.53E-02 7.55E-02 7.64E-02 7.59E-02 7.56E-02879 7.34E-02 7.44E-02 7.51E-02 7.56E-02 7.52E-02 7.50E-02 7.49E-02882 7.21E-02 7.30E-02 7.38E-02 7.43E-02 7.49E-02 7.45E-02 7.42E-02883 7.46E-02 7.60E-02 7.68E-02 7.72E-02 7.79E-02 7.74E-02 7.75E-02885 7.39E-02 7.53E-02 7.60E-02 7.56E-02 7.69E-02 7.64E-02 7.64E-02886 7.24E-02 7.26E-02 7.32E-02 7.33E-02 7.41E-02 7.38E-02 7.35E-02887 7.31E-02 7.35E-02 7.39E-02 7.42E-02 7.50E-02 7.46E-02 7.42E-02891 7.29E-02 7.33E-02 7.37E-02 7.42E-02 7.46E-02 7.43E-02 7.40E-02892 7.16E-02 7.23E-02 7.26E-02 7.32E-02 7.42E-02 7.35E-02 7.33E-02895 7.46E-02 7.48E-02 7.54E-02 7.58E-02 7.65E-02 7.63E-02 7.57E-02896 7.75E-02 7.60E-02 7.62E-02 7.62E-02 7.64E-02 7.63E-02 7.61E-02

Biased StatisticsAverage Biased 7.34E-02 7.46E-02 7.54E-02 7.56E-02 7.63E-02 7.59E-02 7.57E-02Std Dev Biased 9.51E-04 1.11E-03 1.10E-03 1.01E-03 1.24E-03 1.13E-03 1.27E-03Ps90%/90% (+KTL) Biased 7.60E-02 7.77E-02 7.84E-02 7.84E-02 7.97E-02 7.90E-02 7.92E-02Ps90%/90% (-KTL) Biased 7.08E-02 7.16E-02 7.24E-02 7.29E-02 7.29E-02 7.27E-02 7.22E-02Un-Biased StatisticsAverage Un-Biased 7.29E-02 7.33E-02 7.37E-02 7.41E-02 7.49E-02 7.45E-02 7.41E-02Std Dev Un-Biased 1.11E-03 9.90E-04 1.06E-03 1.04E-03 9.66E-04 1.08E-03 9.32E-04Ps90%/90% (+KTL) Un-Biased 7.60E-02 7.60E-02 7.66E-02 7.70E-02 7.75E-02 7.75E-02 7.67E-02Ps90%/90% (-KTL) Un-Biased 6.99E-02 7.06E-02 7.08E-02 7.13E-02 7.22E-02 7.15E-02 7.16E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 159: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

159

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1 m

A @

+/-

15 V

#2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.76. Plot of Output Voltage Swing High IL= 1 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 160: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

160

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.76. Raw data for Output Voltage Swing High IL= 1 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 1 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.25E-02 7.37E-02 7.44E-02 7.51E-02 7.59E-02 7.55E-02 7.51E-02879 6.94E-02 7.06E-02 7.16E-02 7.21E-02 7.17E-02 7.13E-02 7.12E-02882 7.13E-02 7.26E-02 7.33E-02 7.37E-02 7.45E-02 7.41E-02 7.37E-02883 7.46E-02 7.62E-02 7.72E-02 7.75E-02 7.84E-02 7.79E-02 7.76E-02885 7.25E-02 7.45E-02 7.50E-02 7.46E-02 7.59E-02 7.55E-02 7.53E-02886 7.09E-02 7.12E-02 7.15E-02 7.19E-02 7.23E-02 7.21E-02 7.19E-02887 6.96E-02 7.01E-02 7.06E-02 7.08E-02 7.14E-02 7.13E-02 7.06E-02891 7.01E-02 7.06E-02 7.08E-02 7.11E-02 7.16E-02 7.13E-02 7.11E-02892 7.11E-02 7.19E-02 7.24E-02 7.28E-02 7.34E-02 7.31E-02 7.26E-02895 6.97E-02 7.00E-02 7.06E-02 7.09E-02 7.13E-02 7.10E-02 7.08E-02896 7.48E-02 7.33E-02 7.33E-02 7.35E-02 7.36E-02 7.32E-02 7.34E-02

Biased StatisticsAverage Biased 7.21E-02 7.35E-02 7.43E-02 7.46E-02 7.53E-02 7.49E-02 7.46E-02Std Dev Biased 1.90E-03 2.08E-03 2.09E-03 1.97E-03 2.42E-03 2.42E-03 2.35E-03Ps90%/90% (+KTL) Biased 7.73E-02 7.92E-02 8.00E-02 8.00E-02 8.19E-02 8.15E-02 8.10E-02Ps90%/90% (-KTL) Biased 6.69E-02 6.78E-02 6.86E-02 6.92E-02 6.86E-02 6.82E-02 6.81E-02Un-Biased StatisticsAverage Un-Biased 7.03E-02 7.08E-02 7.12E-02 7.15E-02 7.20E-02 7.17E-02 7.14E-02Std Dev Un-Biased 6.78E-04 8.00E-04 7.98E-04 8.50E-04 8.65E-04 8.29E-04 8.34E-04Ps90%/90% (+KTL) Un-Biased 7.22E-02 7.29E-02 7.33E-02 7.38E-02 7.44E-02 7.40E-02 7.37E-02Ps90%/90% (-KTL) Un-Biased 6.84E-02 6.86E-02 6.90E-02 6.92E-02 6.96E-02 6.95E-02 6.91E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 161: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

161

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1 m

A @

+/-

15 V

#3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.77. Plot of Output Voltage Swing High IL= 1 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 162: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

162

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.77. Raw data for Output Voltage Swing High IL= 1 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 1 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.26E-02 7.39E-02 7.43E-02 7.49E-02 7.56E-02 7.51E-02 7.48E-02879 6.91E-02 7.06E-02 7.16E-02 7.19E-02 7.17E-02 7.15E-02 7.10E-02882 7.13E-02 7.27E-02 7.34E-02 7.35E-02 7.40E-02 7.37E-02 7.35E-02883 7.46E-02 7.59E-02 7.68E-02 7.77E-02 7.85E-02 7.80E-02 7.77E-02885 7.26E-02 7.38E-02 7.44E-02 7.44E-02 7.56E-02 7.52E-02 7.50E-02886 7.10E-02 7.09E-02 7.17E-02 7.19E-02 7.24E-02 7.22E-02 7.17E-02887 6.93E-02 7.00E-02 7.02E-02 7.08E-02 7.14E-02 7.11E-02 7.05E-02891 6.96E-02 6.99E-02 7.05E-02 7.07E-02 7.12E-02 7.09E-02 7.07E-02892 7.16E-02 7.21E-02 7.27E-02 7.32E-02 7.38E-02 7.35E-02 7.31E-02895 7.05E-02 7.07E-02 7.11E-02 7.15E-02 7.19E-02 7.18E-02 7.13E-02896 7.42E-02 7.27E-02 7.29E-02 7.28E-02 7.29E-02 7.29E-02 7.28E-02

Biased StatisticsAverage Biased 7.20E-02 7.34E-02 7.41E-02 7.45E-02 7.51E-02 7.47E-02 7.44E-02Std Dev Biased 2.00E-03 1.93E-03 1.89E-03 2.15E-03 2.48E-03 2.36E-03 2.45E-03Ps90%/90% (+KTL) Biased 7.75E-02 7.87E-02 7.93E-02 8.04E-02 8.19E-02 8.12E-02 8.11E-02Ps90%/90% (-KTL) Biased 6.66E-02 6.81E-02 6.89E-02 6.86E-02 6.83E-02 6.82E-02 6.77E-02Un-Biased StatisticsAverage Un-Biased 7.04E-02 7.07E-02 7.12E-02 7.16E-02 7.21E-02 7.19E-02 7.15E-02Std Dev Un-Biased 9.49E-04 8.90E-04 9.97E-04 1.04E-03 1.06E-03 1.07E-03 1.03E-03Ps90%/90% (+KTL) Un-Biased 7.30E-02 7.32E-02 7.40E-02 7.45E-02 7.51E-02 7.48E-02 7.43E-02Ps90%/90% (-KTL) Un-Biased 6.78E-02 6.83E-02 6.85E-02 6.88E-02 6.92E-02 6.90E-02 6.86E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 163: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

163

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1 m

A @

+/-

15 V

#4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.78. Plot of Output Voltage Swing High IL= 1 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 164: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

164

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.78. Raw data for Output Voltage Swing High IL= 1 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 1 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.33E-02 7.46E-02 7.54E-02 7.56E-02 7.65E-02 7.61E-02 7.57E-02879 7.30E-02 7.43E-02 7.52E-02 7.57E-02 7.53E-02 7.50E-02 7.49E-02882 7.17E-02 7.36E-02 7.39E-02 7.41E-02 7.48E-02 7.45E-02 7.41E-02883 7.47E-02 7.60E-02 7.70E-02 7.76E-02 7.82E-02 7.76E-02 7.75E-02885 7.38E-02 7.51E-02 7.57E-02 7.56E-02 7.67E-02 7.64E-02 7.61E-02886 7.19E-02 7.24E-02 7.27E-02 7.31E-02 7.37E-02 7.35E-02 7.32E-02887 7.31E-02 7.35E-02 7.38E-02 7.42E-02 7.49E-02 7.46E-02 7.42E-02891 7.33E-02 7.34E-02 7.40E-02 7.44E-02 7.50E-02 7.48E-02 7.41E-02892 7.22E-02 7.28E-02 7.33E-02 7.37E-02 7.43E-02 7.41E-02 7.35E-02895 7.50E-02 7.55E-02 7.58E-02 7.60E-02 7.68E-02 7.63E-02 7.61E-02896 7.70E-02 7.56E-02 7.55E-02 7.56E-02 7.58E-02 7.58E-02 7.55E-02

Biased StatisticsAverage Biased 7.33E-02 7.47E-02 7.54E-02 7.57E-02 7.63E-02 7.59E-02 7.56E-02Std Dev Biased 1.08E-03 9.16E-04 1.09E-03 1.24E-03 1.32E-03 1.23E-03 1.31E-03Ps90%/90% (+KTL) Biased 7.63E-02 7.72E-02 7.84E-02 7.91E-02 7.99E-02 7.93E-02 7.92E-02Ps90%/90% (-KTL) Biased 7.03E-02 7.22E-02 7.24E-02 7.23E-02 7.27E-02 7.25E-02 7.21E-02Un-Biased StatisticsAverage Un-Biased 7.31E-02 7.35E-02 7.39E-02 7.43E-02 7.49E-02 7.47E-02 7.42E-02Std Dev Un-Biased 1.20E-03 1.20E-03 1.15E-03 1.09E-03 1.15E-03 1.07E-03 1.11E-03Ps90%/90% (+KTL) Un-Biased 7.64E-02 7.68E-02 7.71E-02 7.72E-02 7.81E-02 7.76E-02 7.72E-02Ps90%/90% (-KTL) Un-Biased 6.98E-02 7.02E-02 7.08E-02 7.13E-02 7.18E-02 7.17E-02 7.11E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 165: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

165

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

7.00E-01

8.00E-01

9.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

10 m

A @

+/-

15 V

#1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.79. Plot of Output Voltage Swing High IL= 10 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 166: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

166

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.79. Raw data for Output Voltage Swing High IL= 10 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 10 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.50E-01 3.53E-01 3.55E-01 3.56E-01 3.59E-01 3.57E-01 3.55E-01879 3.47E-01 3.50E-01 3.52E-01 3.53E-01 3.53E-01 3.52E-01 3.51E-01882 3.44E-01 3.46E-01 3.48E-01 3.50E-01 3.52E-01 3.50E-01 3.49E-01883 3.54E-01 3.57E-01 3.60E-01 3.61E-01 3.64E-01 3.61E-01 3.61E-01885 3.53E-01 3.55E-01 3.57E-01 3.57E-01 3.61E-01 3.59E-01 3.59E-01886 3.47E-01 3.47E-01 3.48E-01 3.50E-01 3.52E-01 3.51E-01 3.50E-01887 3.49E-01 3.50E-01 3.52E-01 3.53E-01 3.55E-01 3.53E-01 3.52E-01891 3.47E-01 3.48E-01 3.50E-01 3.51E-01 3.54E-01 3.52E-01 3.50E-01892 3.43E-01 3.45E-01 3.47E-01 3.48E-01 3.51E-01 3.49E-01 3.47E-01895 3.54E-01 3.54E-01 3.56E-01 3.57E-01 3.60E-01 3.59E-01 3.57E-01896 3.66E-01 3.59E-01 3.59E-01 3.60E-01 3.60E-01 3.60E-01 3.60E-01

Biased StatisticsAverage Biased 3.50E-01 3.52E-01 3.54E-01 3.55E-01 3.58E-01 3.56E-01 3.55E-01Std Dev Biased 4.07E-03 4.35E-03 4.41E-03 4.13E-03 5.01E-03 4.70E-03 4.84E-03Ps90%/90% (+KTL) Biased 3.61E-01 3.64E-01 3.67E-01 3.67E-01 3.72E-01 3.69E-01 3.68E-01Ps90%/90% (-KTL) Biased 3.39E-01 3.40E-01 3.42E-01 3.44E-01 3.44E-01 3.43E-01 3.42E-01Un-Biased StatisticsAverage Un-Biased 3.48E-01 3.49E-01 3.51E-01 3.52E-01 3.54E-01 3.53E-01 3.51E-01Std Dev Un-Biased 4.02E-03 3.63E-03 3.66E-03 3.58E-03 3.73E-03 3.83E-03 3.79E-03Ps90%/90% (+KTL) Un-Biased 3.59E-01 3.59E-01 3.61E-01 3.62E-01 3.65E-01 3.63E-01 3.62E-01Ps90%/90% (-KTL) Un-Biased 3.37E-01 3.39E-01 3.41E-01 3.42E-01 3.44E-01 3.42E-01 3.41E-01Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 167: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

167

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

7.00E-01

8.00E-01

9.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

10 m

A @

+/-

15 V

#2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.80. Plot of Output Voltage Swing High IL= 10 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 168: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

168

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.80. Raw data for Output Voltage Swing High IL= 10 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 10 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.49E-01 3.51E-01 3.54E-01 3.55E-01 3.57E-01 3.55E-01 3.54E-01879 3.33E-01 3.36E-01 3.37E-01 3.39E-01 3.39E-01 3.38E-01 3.38E-01882 3.44E-01 3.46E-01 3.48E-01 3.49E-01 3.52E-01 3.50E-01 3.49E-01883 3.53E-01 3.56E-01 3.59E-01 3.61E-01 3.64E-01 3.62E-01 3.61E-01885 3.46E-01 3.48E-01 3.51E-01 3.51E-01 3.54E-01 3.53E-01 3.52E-01886 3.43E-01 3.43E-01 3.45E-01 3.46E-01 3.48E-01 3.47E-01 3.46E-01887 3.34E-01 3.35E-01 3.37E-01 3.38E-01 3.40E-01 3.39E-01 3.38E-01891 3.40E-01 3.40E-01 3.41E-01 3.42E-01 3.45E-01 3.43E-01 3.42E-01892 3.41E-01 3.43E-01 3.45E-01 3.46E-01 3.49E-01 3.47E-01 3.46E-01895 3.39E-01 3.39E-01 3.41E-01 3.41E-01 3.44E-01 3.43E-01 3.41E-01896 3.56E-01 3.49E-01 3.49E-01 3.49E-01 3.50E-01 3.49E-01 3.49E-01

Biased StatisticsAverage Biased 3.45E-01 3.48E-01 3.50E-01 3.51E-01 3.53E-01 3.52E-01 3.51E-01Std Dev Biased 7.46E-03 7.76E-03 8.09E-03 7.93E-03 9.32E-03 8.84E-03 8.60E-03Ps90%/90% (+KTL) Biased 3.66E-01 3.69E-01 3.72E-01 3.73E-01 3.79E-01 3.76E-01 3.74E-01Ps90%/90% (-KTL) Biased 3.25E-01 3.26E-01 3.28E-01 3.29E-01 3.28E-01 3.27E-01 3.27E-01Un-Biased StatisticsAverage Un-Biased 3.39E-01 3.40E-01 3.42E-01 3.43E-01 3.45E-01 3.44E-01 3.42E-01Std Dev Un-Biased 3.34E-03 3.33E-03 3.43E-03 3.33E-03 3.41E-03 3.35E-03 3.53E-03Ps90%/90% (+KTL) Un-Biased 3.49E-01 3.49E-01 3.51E-01 3.52E-01 3.55E-01 3.53E-01 3.52E-01Ps90%/90% (-KTL) Un-Biased 3.30E-01 3.31E-01 3.32E-01 3.34E-01 3.36E-01 3.35E-01 3.33E-01Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 169: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

169

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

7.00E-01

8.00E-01

9.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

10 m

A @

+/-

15 V

#3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.81. Plot of Output Voltage Swing High IL= 10 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 170: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

170

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.81. Raw data for Output Voltage Swing High IL= 10 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 10 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.49E-01 3.52E-01 3.54E-01 3.55E-01 3.57E-01 3.55E-01 3.54E-01879 3.33E-01 3.35E-01 3.37E-01 3.38E-01 3.38E-01 3.38E-01 3.37E-01882 3.43E-01 3.45E-01 3.48E-01 3.48E-01 3.50E-01 3.49E-01 3.48E-01883 3.52E-01 3.56E-01 3.58E-01 3.60E-01 3.63E-01 3.61E-01 3.60E-01885 3.46E-01 3.49E-01 3.51E-01 3.50E-01 3.55E-01 3.53E-01 3.52E-01886 3.43E-01 3.43E-01 3.45E-01 3.46E-01 3.48E-01 3.47E-01 3.46E-01887 3.34E-01 3.35E-01 3.36E-01 3.37E-01 3.40E-01 3.38E-01 3.37E-01891 3.38E-01 3.38E-01 3.40E-01 3.41E-01 3.43E-01 3.42E-01 3.40E-01892 3.42E-01 3.45E-01 3.46E-01 3.48E-01 3.51E-01 3.49E-01 3.47E-01895 3.40E-01 3.41E-01 3.42E-01 3.43E-01 3.45E-01 3.44E-01 3.43E-01896 3.54E-01 3.48E-01 3.48E-01 3.47E-01 3.48E-01 3.47E-01 3.47E-01

Biased StatisticsAverage Biased 3.45E-01 3.47E-01 3.49E-01 3.50E-01 3.53E-01 3.51E-01 3.50E-01Std Dev Biased 7.52E-03 7.92E-03 7.80E-03 8.05E-03 9.43E-03 8.71E-03 8.75E-03Ps90%/90% (+KTL) Biased 3.65E-01 3.69E-01 3.71E-01 3.72E-01 3.79E-01 3.75E-01 3.74E-01Ps90%/90% (-KTL) Biased 3.24E-01 3.26E-01 3.28E-01 3.28E-01 3.27E-01 3.27E-01 3.26E-01Un-Biased StatisticsAverage Un-Biased 3.39E-01 3.40E-01 3.42E-01 3.43E-01 3.45E-01 3.44E-01 3.43E-01Std Dev Un-Biased 3.79E-03 4.01E-03 4.06E-03 4.04E-03 3.99E-03 4.05E-03 4.12E-03Ps90%/90% (+KTL) Un-Biased 3.50E-01 3.51E-01 3.53E-01 3.54E-01 3.56E-01 3.55E-01 3.54E-01Ps90%/90% (-KTL) Un-Biased 3.29E-01 3.29E-01 3.31E-01 3.32E-01 3.35E-01 3.33E-01 3.31E-01Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 171: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

171

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

7.00E-01

8.00E-01

9.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

10 m

A @

+/-

15 V

#4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.82. Plot of Output Voltage Swing High IL= 10 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 172: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

172

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.82. Raw data for Output Voltage Swing High IL= 10 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing High IL= 10 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.51E-01 3.54E-01 3.56E-01 3.57E-01 3.60E-01 3.58E-01 3.56E-01879 3.47E-01 3.50E-01 3.52E-01 3.52E-01 3.53E-01 3.52E-01 3.51E-01882 3.44E-01 3.47E-01 3.49E-01 3.50E-01 3.52E-01 3.50E-01 3.50E-01883 3.55E-01 3.57E-01 3.59E-01 3.61E-01 3.64E-01 3.62E-01 3.61E-01885 3.53E-01 3.55E-01 3.58E-01 3.57E-01 3.61E-01 3.59E-01 3.58E-01886 3.46E-01 3.47E-01 3.48E-01 3.50E-01 3.52E-01 3.50E-01 3.49E-01887 3.49E-01 3.50E-01 3.52E-01 3.53E-01 3.55E-01 3.54E-01 3.53E-01891 3.48E-01 3.49E-01 3.51E-01 3.52E-01 3.54E-01 3.53E-01 3.51E-01892 3.44E-01 3.46E-01 3.48E-01 3.50E-01 3.53E-01 3.50E-01 3.49E-01895 3.55E-01 3.56E-01 3.58E-01 3.59E-01 3.62E-01 3.61E-01 3.59E-01896 3.65E-01 3.58E-01 3.58E-01 3.58E-01 3.58E-01 3.58E-01 3.58E-01

Biased StatisticsAverage Biased 3.50E-01 3.52E-01 3.55E-01 3.55E-01 3.58E-01 3.56E-01 3.55E-01Std Dev Biased 4.39E-03 4.31E-03 4.43E-03 4.37E-03 5.20E-03 4.96E-03 4.68E-03Ps90%/90% (+KTL) Biased 3.62E-01 3.64E-01 3.67E-01 3.67E-01 3.72E-01 3.70E-01 3.68E-01Ps90%/90% (-KTL) Biased 3.38E-01 3.41E-01 3.43E-01 3.43E-01 3.44E-01 3.43E-01 3.42E-01Un-Biased StatisticsAverage Un-Biased 3.49E-01 3.50E-01 3.51E-01 3.53E-01 3.55E-01 3.54E-01 3.52E-01Std Dev Un-Biased 4.16E-03 3.74E-03 3.94E-03 4.03E-03 4.19E-03 4.40E-03 4.08E-03Ps90%/90% (+KTL) Un-Biased 3.60E-01 3.60E-01 3.62E-01 3.64E-01 3.67E-01 3.66E-01 3.63E-01Ps90%/90% (-KTL) Un-Biased 3.37E-01 3.39E-01 3.41E-01 3.42E-01 3.44E-01 3.41E-01 3.41E-01Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 173: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

173

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0

mA

@ +

/- 15

V #

1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.83. Plot of Output Voltage Swing Low IL= 0 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 174: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

174

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.83. Raw data for Output Voltage Swing Low IL= 0 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 0 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.01E-02 2.04E-02 2.08E-02 2.08E-02 2.11E-02 2.09E-02 2.07E-02879 2.04E-02 2.09E-02 2.09E-02 2.12E-02 2.11E-02 2.11E-02 2.08E-02882 1.93E-02 1.97E-02 1.97E-02 2.00E-02 2.02E-02 2.00E-02 2.01E-02883 1.97E-02 2.02E-02 2.00E-02 2.02E-02 2.06E-02 2.04E-02 2.03E-02885 1.91E-02 1.92E-02 1.96E-02 1.92E-02 1.99E-02 1.97E-02 1.96E-02886 1.97E-02 2.00E-02 2.01E-02 2.04E-02 2.05E-02 2.03E-02 2.01E-02887 1.95E-02 1.95E-02 1.97E-02 1.96E-02 2.00E-02 2.00E-02 1.98E-02891 1.95E-02 1.96E-02 1.97E-02 1.99E-02 2.00E-02 2.00E-02 2.00E-02892 1.96E-02 1.99E-02 2.01E-02 2.03E-02 2.05E-02 2.04E-02 2.01E-02895 1.96E-02 1.93E-02 1.96E-02 1.99E-02 2.00E-02 2.00E-02 1.97E-02896 1.92E-02 1.87E-02 1.87E-02 1.87E-02 1.88E-02 1.87E-02 1.87E-02

Biased StatisticsAverage Biased 1.97E-02 2.01E-02 2.02E-02 2.03E-02 2.06E-02 2.04E-02 2.03E-02Std Dev Biased 5.32E-04 6.37E-04 5.93E-04 7.51E-04 5.29E-04 5.56E-04 5.10E-04Ps90%/90% (+KTL) Biased 2.12E-02 2.18E-02 2.18E-02 2.24E-02 2.20E-02 2.19E-02 2.17E-02Ps90%/90% (-KTL) Biased 1.83E-02 1.83E-02 1.86E-02 1.82E-02 1.91E-02 1.89E-02 1.89E-02Un-Biased StatisticsAverage Un-Biased 1.96E-02 1.97E-02 1.98E-02 2.00E-02 2.02E-02 2.01E-02 1.99E-02Std Dev Un-Biased 1.04E-04 2.72E-04 2.50E-04 3.28E-04 2.71E-04 2.18E-04 1.81E-04Ps90%/90% (+KTL) Un-Biased 1.99E-02 2.04E-02 2.05E-02 2.09E-02 2.10E-02 2.07E-02 2.04E-02Ps90%/90% (-KTL) Un-Biased 1.93E-02 1.89E-02 1.91E-02 1.91E-02 1.95E-02 1.95E-02 1.94E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 175: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

175

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0

mA

@ +

/- 15

V #

2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.84. Plot of Output Voltage Swing Low IL= 0 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 176: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

176

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.84. Raw data for Output Voltage Swing Low IL= 0 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 0 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.96E-02 2.00E-02 2.02E-02 2.03E-02 2.07E-02 2.05E-02 2.02E-02879 2.05E-02 2.08E-02 2.11E-02 2.12E-02 2.12E-02 2.11E-02 2.09E-02882 1.96E-02 1.98E-02 2.00E-02 2.03E-02 2.04E-02 2.03E-02 2.02E-02883 2.05E-02 2.11E-02 2.11E-02 2.15E-02 2.18E-02 2.17E-02 2.16E-02885 1.97E-02 2.01E-02 2.04E-02 2.03E-02 2.08E-02 2.06E-02 2.05E-02886 2.02E-02 2.04E-02 2.04E-02 2.06E-02 2.09E-02 2.07E-02 2.06E-02887 2.06E-02 2.06E-02 2.07E-02 2.10E-02 2.12E-02 2.11E-02 2.09E-02891 2.06E-02 2.06E-02 2.09E-02 2.09E-02 2.13E-02 2.11E-02 2.10E-02892 2.10E-02 2.10E-02 2.14E-02 2.15E-02 2.19E-02 2.18E-02 2.15E-02895 2.15E-02 2.14E-02 2.15E-02 2.17E-02 2.20E-02 2.18E-02 2.17E-02896 2.03E-02 1.95E-02 1.97E-02 1.96E-02 1.98E-02 1.94E-02 1.97E-02

Biased StatisticsAverage Biased 2.00E-02 2.03E-02 2.06E-02 2.07E-02 2.10E-02 2.08E-02 2.07E-02Std Dev Biased 4.90E-04 5.61E-04 5.28E-04 5.68E-04 5.50E-04 5.61E-04 5.81E-04Ps90%/90% (+KTL) Biased 2.13E-02 2.19E-02 2.20E-02 2.23E-02 2.25E-02 2.23E-02 2.23E-02Ps90%/90% (-KTL) Biased 1.86E-02 1.88E-02 1.91E-02 1.92E-02 1.95E-02 1.93E-02 1.91E-02Un-Biased StatisticsAverage Un-Biased 2.08E-02 2.08E-02 2.10E-02 2.11E-02 2.15E-02 2.13E-02 2.11E-02Std Dev Un-Biased 4.99E-04 4.15E-04 4.59E-04 4.39E-04 4.95E-04 4.88E-04 4.44E-04Ps90%/90% (+KTL) Un-Biased 2.21E-02 2.19E-02 2.22E-02 2.23E-02 2.28E-02 2.26E-02 2.23E-02Ps90%/90% (-KTL) Un-Biased 1.94E-02 1.97E-02 1.97E-02 1.99E-02 2.01E-02 1.99E-02 1.99E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 177: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

177

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0

mA

@ +

/- 15

V #

3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.85. Plot of Output Voltage Swing Low IL= 0 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 178: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

178

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.85. Raw data for Output Voltage Swing Low IL= 0 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 0 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.96E-02 1.98E-02 1.99E-02 2.01E-02 2.05E-02 2.02E-02 2.01E-02879 2.00E-02 2.04E-02 2.07E-02 2.07E-02 2.09E-02 2.07E-02 2.05E-02882 1.93E-02 1.96E-02 1.97E-02 1.98E-02 2.01E-02 2.00E-02 2.00E-02883 2.02E-02 2.06E-02 2.09E-02 2.10E-02 2.15E-02 2.13E-02 2.10E-02885 2.03E-02 2.07E-02 2.09E-02 2.07E-02 2.12E-02 2.11E-02 2.09E-02886 1.97E-02 2.00E-02 2.01E-02 2.01E-02 2.07E-02 2.05E-02 2.02E-02887 2.03E-02 2.04E-02 2.06E-02 2.07E-02 2.11E-02 2.10E-02 2.07E-02891 2.03E-02 2.06E-02 2.09E-02 2.09E-02 2.11E-02 2.09E-02 2.08E-02892 2.03E-02 2.06E-02 2.08E-02 2.10E-02 2.13E-02 2.12E-02 2.08E-02895 2.07E-02 2.08E-02 2.12E-02 2.11E-02 2.13E-02 2.12E-02 2.10E-02896 1.98E-02 1.93E-02 1.91E-02 1.90E-02 1.91E-02 1.93E-02 1.91E-02

Biased StatisticsAverage Biased 1.99E-02 2.02E-02 2.04E-02 2.05E-02 2.08E-02 2.07E-02 2.05E-02Std Dev Biased 4.35E-04 5.18E-04 5.81E-04 4.86E-04 5.37E-04 5.59E-04 4.63E-04Ps90%/90% (+KTL) Biased 2.10E-02 2.16E-02 2.20E-02 2.18E-02 2.23E-02 2.22E-02 2.18E-02Ps90%/90% (-KTL) Biased 1.87E-02 1.88E-02 1.88E-02 1.91E-02 1.94E-02 1.91E-02 1.92E-02Un-Biased StatisticsAverage Un-Biased 2.03E-02 2.05E-02 2.07E-02 2.08E-02 2.11E-02 2.10E-02 2.07E-02Std Dev Un-Biased 3.57E-04 3.13E-04 3.91E-04 3.83E-04 2.32E-04 3.00E-04 2.99E-04Ps90%/90% (+KTL) Un-Biased 2.13E-02 2.13E-02 2.18E-02 2.18E-02 2.17E-02 2.18E-02 2.15E-02Ps90%/90% (-KTL) Un-Biased 1.93E-02 1.96E-02 1.96E-02 1.97E-02 2.05E-02 2.01E-02 1.99E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 179: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

179

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0

mA

@ +

/- 15

V #

4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.86. Plot of Output Voltage Swing Low IL= 0 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 180: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

180

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.86. Raw data for Output Voltage Swing Low IL= 0 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 0 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.03E-02 2.05E-02 2.08E-02 2.09E-02 2.13E-02 2.10E-02 2.08E-02879 2.15E-02 2.21E-02 2.21E-02 2.25E-02 2.22E-02 2.22E-02 2.21E-02882 2.00E-02 2.02E-02 2.04E-02 2.05E-02 2.09E-02 2.08E-02 2.07E-02883 1.98E-02 2.01E-02 2.05E-02 2.05E-02 2.08E-02 2.06E-02 2.07E-02885 1.97E-02 1.98E-02 2.01E-02 1.98E-02 2.05E-02 2.02E-02 2.02E-02886 2.03E-02 2.06E-02 2.07E-02 2.08E-02 2.11E-02 2.08E-02 2.08E-02887 2.00E-02 2.02E-02 2.03E-02 2.04E-02 2.07E-02 2.04E-02 2.04E-02891 2.03E-02 2.01E-02 2.02E-02 2.06E-02 2.09E-02 2.06E-02 2.04E-02892 1.99E-02 2.02E-02 2.04E-02 2.06E-02 2.09E-02 2.08E-02 2.06E-02895 2.00E-02 1.99E-02 2.03E-02 2.03E-02 2.07E-02 2.07E-02 2.05E-02896 1.94E-02 1.89E-02 1.89E-02 1.89E-02 1.88E-02 1.89E-02 1.89E-02

Biased StatisticsAverage Biased 2.02E-02 2.05E-02 2.08E-02 2.08E-02 2.11E-02 2.10E-02 2.09E-02Std Dev Biased 7.13E-04 8.94E-04 7.72E-04 9.87E-04 6.45E-04 7.23E-04 6.94E-04Ps90%/90% (+KTL) Biased 2.22E-02 2.30E-02 2.29E-02 2.36E-02 2.29E-02 2.29E-02 2.28E-02Ps90%/90% (-KTL) Biased 1.83E-02 1.81E-02 1.86E-02 1.81E-02 1.94E-02 1.90E-02 1.90E-02Un-Biased StatisticsAverage Un-Biased 2.01E-02 2.02E-02 2.04E-02 2.05E-02 2.08E-02 2.07E-02 2.05E-02Std Dev Un-Biased 1.73E-04 2.25E-04 1.98E-04 2.07E-04 1.70E-04 1.51E-04 1.79E-04Ps90%/90% (+KTL) Un-Biased 2.06E-02 2.08E-02 2.09E-02 2.11E-02 2.13E-02 2.11E-02 2.10E-02Ps90%/90% (-KTL) Un-Biased 1.96E-02 1.96E-02 1.98E-02 2.00E-02 2.04E-02 2.03E-02 2.00E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 181: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

181

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1

mA

@ +

/- 15

V #

1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.87. Plot of Output Voltage Swing Low IL= 1 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 182: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

182

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.87. Raw data for Output Voltage Swing Low IL= 1 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 1 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.52E-02 5.56E-02 5.59E-02 5.60E-02 5.65E-02 5.62E-02 5.61E-02879 5.51E-02 5.55E-02 5.57E-02 5.57E-02 5.57E-02 5.56E-02 5.55E-02882 5.38E-02 5.41E-02 5.44E-02 5.45E-02 5.49E-02 5.49E-02 5.46E-02883 5.47E-02 5.50E-02 5.53E-02 5.55E-02 5.57E-02 5.57E-02 5.54E-02885 5.38E-02 5.41E-02 5.44E-02 5.41E-02 5.46E-02 5.47E-02 5.44E-02886 5.48E-02 5.47E-02 5.48E-02 5.50E-02 5.53E-02 5.53E-02 5.50E-02887 5.41E-02 5.42E-02 5.43E-02 5.44E-02 5.49E-02 5.46E-02 5.46E-02891 5.40E-02 5.40E-02 5.43E-02 5.43E-02 5.47E-02 5.46E-02 5.44E-02892 5.41E-02 5.43E-02 5.47E-02 5.45E-02 5.52E-02 5.48E-02 5.47E-02895 5.44E-02 5.44E-02 5.46E-02 5.47E-02 5.52E-02 5.51E-02 5.48E-02896 5.44E-02 5.33E-02 5.35E-02 5.34E-02 5.37E-02 5.33E-02 5.34E-02

Biased StatisticsAverage Biased 5.45E-02 5.49E-02 5.51E-02 5.52E-02 5.55E-02 5.54E-02 5.52E-02Std Dev Biased 6.71E-04 7.44E-04 7.32E-04 8.15E-04 7.47E-04 6.16E-04 7.08E-04Ps90%/90% (+KTL) Biased 5.64E-02 5.69E-02 5.72E-02 5.74E-02 5.75E-02 5.71E-02 5.71E-02Ps90%/90% (-KTL) Biased 5.27E-02 5.28E-02 5.31E-02 5.29E-02 5.34E-02 5.37E-02 5.33E-02Un-Biased StatisticsAverage Un-Biased 5.43E-02 5.43E-02 5.45E-02 5.46E-02 5.50E-02 5.49E-02 5.47E-02Std Dev Un-Biased 3.51E-04 2.66E-04 2.48E-04 2.75E-04 2.39E-04 3.33E-04 2.17E-04Ps90%/90% (+KTL) Un-Biased 5.53E-02 5.51E-02 5.52E-02 5.53E-02 5.57E-02 5.58E-02 5.53E-02Ps90%/90% (-KTL) Un-Biased 5.33E-02 5.36E-02 5.38E-02 5.38E-02 5.44E-02 5.39E-02 5.41E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 183: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

183

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1

mA

@ +

/- 15

V #

2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.88. Plot of Output Voltage Swing Low IL= 1 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 184: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

184

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.88. Raw data for Output Voltage Swing Low IL= 1 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 1 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.47E-02 5.52E-02 5.53E-02 5.56E-02 5.60E-02 5.58E-02 5.55E-02879 5.45E-02 5.48E-02 5.53E-02 5.54E-02 5.51E-02 5.52E-02 5.50E-02882 5.45E-02 5.47E-02 5.50E-02 5.52E-02 5.52E-02 5.52E-02 5.53E-02883 5.57E-02 5.60E-02 5.63E-02 5.66E-02 5.69E-02 5.69E-02 5.67E-02885 5.47E-02 5.50E-02 5.55E-02 5.53E-02 5.57E-02 5.56E-02 5.55E-02886 5.49E-02 5.48E-02 5.50E-02 5.51E-02 5.53E-02 5.51E-02 5.52E-02887 5.46E-02 5.46E-02 5.49E-02 5.49E-02 5.54E-02 5.51E-02 5.50E-02891 5.47E-02 5.47E-02 5.51E-02 5.51E-02 5.55E-02 5.52E-02 5.50E-02892 5.54E-02 5.58E-02 5.60E-02 5.60E-02 5.64E-02 5.62E-02 5.61E-02895 5.54E-02 5.54E-02 5.56E-02 5.57E-02 5.61E-02 5.58E-02 5.55E-02896 5.55E-02 5.45E-02 5.44E-02 5.45E-02 5.46E-02 5.45E-02 5.44E-02

Biased StatisticsAverage Biased 5.48E-02 5.52E-02 5.55E-02 5.56E-02 5.58E-02 5.57E-02 5.56E-02Std Dev Biased 4.93E-04 5.34E-04 5.13E-04 5.84E-04 6.97E-04 6.90E-04 6.73E-04Ps90%/90% (+KTL) Biased 5.62E-02 5.66E-02 5.69E-02 5.72E-02 5.77E-02 5.76E-02 5.74E-02Ps90%/90% (-KTL) Biased 5.35E-02 5.37E-02 5.41E-02 5.40E-02 5.39E-02 5.38E-02 5.37E-02Un-Biased StatisticsAverage Un-Biased 5.50E-02 5.50E-02 5.53E-02 5.54E-02 5.58E-02 5.55E-02 5.54E-02Std Dev Un-Biased 3.75E-04 5.18E-04 4.79E-04 4.84E-04 4.88E-04 4.94E-04 4.57E-04Ps90%/90% (+KTL) Un-Biased 5.60E-02 5.65E-02 5.66E-02 5.67E-02 5.71E-02 5.68E-02 5.66E-02Ps90%/90% (-KTL) Un-Biased 5.39E-02 5.36E-02 5.40E-02 5.40E-02 5.44E-02 5.41E-02 5.41E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 185: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

185

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1

mA

@ +

/- 15

V #

3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.89. Plot of Output Voltage Swing Low IL= 1 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 186: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

186

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.89. Raw data for Output Voltage Swing Low IL= 1 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 1 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.43E-02 5.48E-02 5.49E-02 5.52E-02 5.56E-02 5.53E-02 5.50E-02879 5.36E-02 5.40E-02 5.44E-02 5.46E-02 5.46E-02 5.45E-02 5.45E-02882 5.40E-02 5.43E-02 5.46E-02 5.46E-02 5.50E-02 5.48E-02 5.46E-02883 5.48E-02 5.52E-02 5.56E-02 5.57E-02 5.61E-02 5.61E-02 5.59E-02885 5.46E-02 5.50E-02 5.53E-02 5.50E-02 5.58E-02 5.56E-02 5.54E-02886 5.42E-02 5.42E-02 5.45E-02 5.45E-02 5.49E-02 5.46E-02 5.47E-02887 5.40E-02 5.40E-02 5.44E-02 5.45E-02 5.49E-02 5.45E-02 5.46E-02891 5.44E-02 5.44E-02 5.44E-02 5.48E-02 5.52E-02 5.48E-02 5.47E-02892 5.46E-02 5.50E-02 5.52E-02 5.54E-02 5.56E-02 5.54E-02 5.53E-02895 5.48E-02 5.48E-02 5.50E-02 5.50E-02 5.55E-02 5.52E-02 5.50E-02896 5.49E-02 5.39E-02 5.37E-02 5.38E-02 5.39E-02 5.39E-02 5.39E-02

Biased StatisticsAverage Biased 5.43E-02 5.47E-02 5.50E-02 5.50E-02 5.54E-02 5.53E-02 5.51E-02Std Dev Biased 4.83E-04 5.04E-04 5.20E-04 4.62E-04 6.34E-04 6.24E-04 5.71E-04Ps90%/90% (+KTL) Biased 5.56E-02 5.60E-02 5.64E-02 5.63E-02 5.71E-02 5.70E-02 5.66E-02Ps90%/90% (-KTL) Biased 5.29E-02 5.33E-02 5.35E-02 5.38E-02 5.37E-02 5.36E-02 5.35E-02Un-Biased StatisticsAverage Un-Biased 5.44E-02 5.45E-02 5.47E-02 5.48E-02 5.52E-02 5.49E-02 5.49E-02Std Dev Un-Biased 3.29E-04 4.00E-04 3.78E-04 3.73E-04 3.11E-04 3.79E-04 2.95E-04Ps90%/90% (+KTL) Un-Biased 5.53E-02 5.56E-02 5.57E-02 5.59E-02 5.60E-02 5.59E-02 5.57E-02Ps90%/90% (-KTL) Un-Biased 5.35E-02 5.34E-02 5.37E-02 5.38E-02 5.43E-02 5.39E-02 5.40E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 187: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

187

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1

mA

@ +

/- 15

V #

4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.90. Plot of Output Voltage Swing Low IL= 1 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 188: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

188

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.90. Raw data for Output Voltage Swing Low IL= 1 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 1 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.54E-02 5.58E-02 5.62E-02 5.62E-02 5.66E-02 5.66E-02 5.65E-02879 5.61E-02 5.64E-02 5.67E-02 5.69E-02 5.67E-02 5.67E-02 5.67E-02882 5.46E-02 5.52E-02 5.52E-02 5.54E-02 5.60E-02 5.57E-02 5.55E-02883 5.52E-02 5.55E-02 5.56E-02 5.59E-02 5.62E-02 5.62E-02 5.59E-02885 5.47E-02 5.49E-02 5.52E-02 5.50E-02 5.57E-02 5.54E-02 5.54E-02886 5.52E-02 5.53E-02 5.56E-02 5.57E-02 5.60E-02 5.58E-02 5.58E-02887 5.48E-02 5.49E-02 5.52E-02 5.52E-02 5.56E-02 5.54E-02 5.53E-02891 5.50E-02 5.51E-02 5.54E-02 5.55E-02 5.58E-02 5.55E-02 5.55E-02892 5.48E-02 5.48E-02 5.54E-02 5.55E-02 5.58E-02 5.55E-02 5.53E-02895 5.52E-02 5.54E-02 5.55E-02 5.58E-02 5.61E-02 5.57E-02 5.57E-02896 5.50E-02 5.40E-02 5.42E-02 5.39E-02 5.40E-02 5.40E-02 5.40E-02

Biased StatisticsAverage Biased 5.52E-02 5.55E-02 5.58E-02 5.59E-02 5.62E-02 5.61E-02 5.60E-02Std Dev Biased 6.00E-04 5.74E-04 6.44E-04 7.30E-04 4.43E-04 5.42E-04 5.76E-04Ps90%/90% (+KTL) Biased 5.68E-02 5.71E-02 5.76E-02 5.79E-02 5.75E-02 5.76E-02 5.76E-02Ps90%/90% (-KTL) Biased 5.35E-02 5.40E-02 5.40E-02 5.39E-02 5.50E-02 5.46E-02 5.44E-02Un-Biased StatisticsAverage Un-Biased 5.50E-02 5.51E-02 5.54E-02 5.55E-02 5.58E-02 5.56E-02 5.55E-02Std Dev Un-Biased 1.74E-04 2.54E-04 1.15E-04 2.15E-04 1.84E-04 1.38E-04 2.22E-04Ps90%/90% (+KTL) Un-Biased 5.55E-02 5.58E-02 5.57E-02 5.61E-02 5.63E-02 5.59E-02 5.61E-02Ps90%/90% (-KTL) Un-Biased 5.45E-02 5.44E-02 5.51E-02 5.49E-02 5.53E-02 5.52E-02 5.49E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 189: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

189

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 10

mA

@ +

/- 15

V #

1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.91. Plot of Output Voltage Swing Low IL= 10 mA @ +/- 15 V #1 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 190: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

190

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.91. Raw data for Output Voltage Swing Low IL= 10 mA @ +/- 15 V #1 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 10 mA @ +/- 15 V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.23E-01 2.22E-01 2.22E-01879 2.16E-01 2.17E-01 2.18E-01 2.18E-01 2.17E-01 2.18E-01 2.17E-01882 2.17E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01883 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01885 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01886 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01887 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01891 2.15E-01 2.15E-01 2.15E-01 2.16E-01 2.17E-01 2.15E-01 2.15E-01892 2.15E-01 2.16E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01895 2.19E-01 2.18E-01 2.19E-01 2.18E-01 2.19E-01 2.18E-01 2.19E-01896 2.22E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01

Biased StatisticsAverage Biased 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01Std Dev Biased 1.70E-03 2.01E-03 2.06E-03 1.99E-03 2.39E-03 2.02E-03 1.80E-03Ps90%/90% (+KTL) Biased 2.22E-01 2.24E-01 2.24E-01 2.24E-01 2.26E-01 2.24E-01 2.24E-01Ps90%/90% (-KTL) Biased 2.13E-01 2.13E-01 2.13E-01 2.13E-01 2.13E-01 2.13E-01 2.14E-01Un-Biased StatisticsAverage Un-Biased 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 2.17E-01 2.17E-01Std Dev Un-Biased 1.84E-03 1.43E-03 1.49E-03 1.37E-03 1.46E-03 1.54E-03 1.66E-03Ps90%/90% (+KTL) Un-Biased 2.22E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01Ps90%/90% (-KTL) Un-Biased 2.12E-01 2.13E-01 2.13E-01 2.14E-01 2.14E-01 2.13E-01 2.13E-01Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 191: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

191

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 10

mA

@ +

/- 15

V #

2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.92. Plot of Output Voltage Swing Low IL= 10 mA @ +/- 15 V #2 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 192: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

192

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.92. Raw data for Output Voltage Swing Low IL= 10 mA @ +/- 15 V #2 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 10 mA @ +/- 15 V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.23E-01 2.23E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.24E-01879 2.13E-01 2.14E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01 2.14E-01882 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.22E-01883 2.17E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01885 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01886 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.20E-01 2.20E-01887 2.14E-01 2.14E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01891 2.19E-01 2.18E-01 2.19E-01 2.18E-01 2.20E-01 2.19E-01 2.19E-01892 2.18E-01 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01895 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01896 2.23E-01 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01

Biased StatisticsAverage Biased 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.20E-01 2.19E-01Std Dev Biased 3.60E-03 3.52E-03 3.38E-03 3.63E-03 3.83E-03 3.62E-03 3.54E-03Ps90%/90% (+KTL) Biased 2.28E-01 2.28E-01 2.29E-01 2.29E-01 2.31E-01 2.30E-01 2.29E-01Ps90%/90% (-KTL) Biased 2.08E-01 2.09E-01 2.10E-01 2.10E-01 2.10E-01 2.10E-01 2.10E-01Un-Biased StatisticsAverage Un-Biased 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.19E-01 2.18E-01 2.18E-01Std Dev Un-Biased 2.12E-03 2.04E-03 2.08E-03 1.84E-03 2.02E-03 1.85E-03 2.05E-03Ps90%/90% (+KTL) Un-Biased 2.24E-01 2.23E-01 2.24E-01 2.23E-01 2.24E-01 2.23E-01 2.24E-01Ps90%/90% (-KTL) Un-Biased 2.12E-01 2.12E-01 2.12E-01 2.13E-01 2.13E-01 2.13E-01 2.13E-01Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 193: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

193

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 10

mA

@ +

/- 15

V #

3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.93. Plot of Output Voltage Swing Low IL= 10 mA @ +/- 15 V #3 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 194: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

194

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.93. Raw data for Output Voltage Swing Low IL= 10 mA @ +/- 15 V #3 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 10 mA @ +/- 15 V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.23E-01 2.23E-01 2.22E-01879 2.11E-01 2.12E-01 2.12E-01 2.12E-01 2.12E-01 2.12E-01 2.12E-01882 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01883 2.15E-01 2.15E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01885 2.15E-01 2.16E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.17E-01886 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.19E-01887 2.12E-01 2.12E-01 2.12E-01 2.13E-01 2.13E-01 2.12E-01 2.13E-01891 2.16E-01 2.16E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01892 2.15E-01 2.15E-01 2.16E-01 2.16E-01 2.16E-01 2.15E-01 2.16E-01895 2.16E-01 2.16E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.17E-01896 2.21E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01 2.16E-01

Biased StatisticsAverage Biased 2.16E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 2.17E-01Std Dev Biased 3.82E-03 3.88E-03 3.76E-03 3.87E-03 4.25E-03 4.08E-03 3.71E-03Ps90%/90% (+KTL) Biased 2.27E-01 2.27E-01 2.27E-01 2.28E-01 2.29E-01 2.29E-01 2.27E-01Ps90%/90% (-KTL) Biased 2.06E-01 2.06E-01 2.07E-01 2.07E-01 2.06E-01 2.06E-01 2.07E-01Un-Biased StatisticsAverage Un-Biased 2.15E-01 2.15E-01 2.16E-01 2.16E-01 2.16E-01 2.16E-01 2.16E-01Std Dev Un-Biased 2.43E-03 2.14E-03 2.09E-03 2.01E-03 1.98E-03 2.17E-03 2.11E-03Ps90%/90% (+KTL) Un-Biased 2.22E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01Ps90%/90% (-KTL) Un-Biased 2.09E-01 2.09E-01 2.10E-01 2.10E-01 2.11E-01 2.10E-01 2.10E-01Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 195: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

195

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-01

2.00E-01

3.00E-01

4.00E-01

5.00E-01

6.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 10

mA

@ +

/- 15

V #

4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.94. Plot of Output Voltage Swing Low IL= 10 mA @ +/- 15 V #4 (V) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 196: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

196

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.94. Raw data for Output Voltage Swing Low IL= 10 mA @ +/- 15 V #4 (V) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Output Voltage Swing Low IL= 10 mA @ +/- 15 V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.22E-01 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01879 2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.20E-01882 2.19E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.21E-01883 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01885 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.20E-01 2.20E-01886 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.22E-01887 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.20E-01 2.20E-01891 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01892 2.17E-01 2.18E-01 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01895 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01896 2.25E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.20E-01 2.20E-01

Biased StatisticsAverage Biased 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01Std Dev Biased 1.33E-03 1.42E-03 1.53E-03 1.63E-03 1.56E-03 1.70E-03 1.29E-03Ps90%/90% (+KTL) Biased 2.24E-01 2.24E-01 2.25E-01 2.26E-01 2.26E-01 2.26E-01 2.25E-01Ps90%/90% (-KTL) Biased 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01Un-Biased StatisticsAverage Un-Biased 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.20E-01 2.20E-01Std Dev Un-Biased 1.76E-03 1.38E-03 1.28E-03 1.29E-03 1.31E-03 1.27E-03 1.39E-03Ps90%/90% (+KTL) Un-Biased 2.25E-01 2.24E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.24E-01Ps90%/90% (-KTL) Un-Biased 2.15E-01 2.16E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 197: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

197

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E-02

-3.50E-02

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

+/-

15 V

#1

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.95. Plot of Positive Short-Circuit Current @ +/- 15 V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 198: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

198

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.95. Raw data for Positive Short-Circuit Current @ +/- 15 V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ +/- 15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.67E-02 -3.58E-02 -3.53E-02 -3.48E-02 -3.42E-02 -3.45E-02 -3.46E-02879 -3.47E-02 -3.37E-02 -3.34E-02 -3.27E-02 -3.26E-02 -3.33E-02 -3.35E-02882 -3.70E-02 -3.61E-02 -3.55E-02 -3.50E-02 -3.44E-02 -3.47E-02 -3.50E-02883 -3.42E-02 -3.30E-02 -3.25E-02 -3.21E-02 -3.13E-02 -3.17E-02 -3.21E-02885 -3.68E-02 -3.57E-02 -3.51E-02 -3.52E-02 -3.40E-02 -3.44E-02 -3.48E-02886 -3.71E-02 -3.65E-02 -3.61E-02 -3.57E-02 -3.51E-02 -3.50E-02 -3.59E-02887 -3.61E-02 -3.55E-02 -3.51E-02 -3.46E-02 -3.41E-02 -3.40E-02 -3.49E-02891 -3.49E-02 -3.43E-02 -3.40E-02 -3.36E-02 -3.30E-02 -3.30E-02 -3.37E-02892 -3.47E-02 -3.42E-02 -3.38E-02 -3.33E-02 -3.26E-02 -3.26E-02 -3.37E-02895 -3.53E-02 -3.47E-02 -3.43E-02 -3.38E-02 -3.31E-02 -3.32E-02 -3.41E-02896 -3.73E-02 -3.59E-02 -3.59E-02 -3.60E-02 -3.61E-02 -3.60E-02 -3.60E-02

Biased StatisticsAverage Biased -3.59E-02 -3.49E-02 -3.44E-02 -3.40E-02 -3.33E-02 -3.37E-02 -3.40E-02Std Dev Biased 1.33E-03 1.39E-03 1.33E-03 1.44E-03 1.30E-03 1.25E-03 1.24E-03Ps90%/90% (+KTL) Biased -3.22E-02 -3.10E-02 -3.07E-02 -3.00E-02 -2.97E-02 -3.03E-02 -3.06E-02Ps90%/90% (-KTL) Biased -3.95E-02 -3.87E-02 -3.80E-02 -3.79E-02 -3.69E-02 -3.72E-02 -3.74E-02Un-Biased StatisticsAverage Un-Biased -3.56E-02 -3.50E-02 -3.46E-02 -3.42E-02 -3.36E-02 -3.35E-02 -3.44E-02Std Dev Un-Biased 9.83E-04 9.41E-04 9.21E-04 9.50E-04 1.01E-03 9.89E-04 9.37E-04Ps90%/90% (+KTL) Un-Biased -3.29E-02 -3.24E-02 -3.21E-02 -3.16E-02 -3.08E-02 -3.08E-02 -3.19E-02Ps90%/90% (-KTL) Un-Biased -3.83E-02 -3.76E-02 -3.72E-02 -3.68E-02 -3.63E-02 -3.63E-02 -3.70E-02Specification MAX -1.50E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 199: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

199

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E-02

-3.50E-02

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

+/-

15 V

#2

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.96. Plot of Positive Short-Circuit Current @ +/- 15 V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 200: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

200

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.96. Raw data for Positive Short-Circuit Current @ +/- 15 V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ +/- 15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.96E-02 -3.86E-02 -3.81E-02 -3.75E-02 -3.69E-02 -3.73E-02 -3.74E-02879 -3.51E-02 -3.41E-02 -3.37E-02 -3.29E-02 -3.26E-02 -3.34E-02 -3.37E-02882 -3.97E-02 -3.87E-02 -3.81E-02 -3.77E-02 -3.71E-02 -3.73E-02 -3.76E-02883 -3.27E-02 -3.14E-02 -3.08E-02 -3.04E-02 -2.96E-02 -2.99E-02 -3.03E-02885 -3.55E-02 -3.44E-02 -3.38E-02 -3.39E-02 -3.26E-02 -3.31E-02 -3.34E-02886 -3.89E-02 -3.82E-02 -3.78E-02 -3.74E-02 -3.68E-02 -3.68E-02 -3.76E-02887 -3.48E-02 -3.42E-02 -3.37E-02 -3.32E-02 -3.25E-02 -3.25E-02 -3.36E-02891 -3.81E-02 -3.74E-02 -3.71E-02 -3.66E-02 -3.61E-02 -3.60E-02 -3.68E-02892 -3.45E-02 -3.40E-02 -3.36E-02 -3.31E-02 -3.24E-02 -3.24E-02 -3.34E-02895 -3.91E-02 -3.84E-02 -3.80E-02 -3.76E-02 -3.68E-02 -3.69E-02 -3.78E-02896 -3.79E-02 -3.65E-02 -3.65E-02 -3.65E-02 -3.67E-02 -3.65E-02 -3.65E-02

Biased StatisticsAverage Biased -3.65E-02 -3.54E-02 -3.49E-02 -3.45E-02 -3.38E-02 -3.42E-02 -3.45E-02Std Dev Biased 3.03E-03 3.14E-03 3.15E-03 3.13E-03 3.19E-03 3.14E-03 3.06E-03Ps90%/90% (+KTL) Biased -2.82E-02 -2.68E-02 -2.63E-02 -2.59E-02 -2.50E-02 -2.56E-02 -2.61E-02Ps90%/90% (-KTL) Biased -4.48E-02 -4.41E-02 -4.35E-02 -4.31E-02 -4.25E-02 -4.28E-02 -4.29E-02Un-Biased StatisticsAverage Un-Biased -3.71E-02 -3.65E-02 -3.60E-02 -3.56E-02 -3.49E-02 -3.49E-02 -3.58E-02Std Dev Un-Biased 2.25E-03 2.20E-03 2.21E-03 2.24E-03 2.28E-03 2.28E-03 2.17E-03Ps90%/90% (+KTL) Un-Biased -3.09E-02 -3.04E-02 -3.00E-02 -2.94E-02 -2.87E-02 -2.86E-02 -2.99E-02Ps90%/90% (-KTL) Un-Biased -4.32E-02 -4.25E-02 -4.21E-02 -4.17E-02 -4.12E-02 -4.12E-02 -4.18E-02Specification MAX -1.50E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 201: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

201

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E-02

-3.50E-02

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

+/-

15 V

#3

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.97. Plot of Positive Short-Circuit Current @ +/- 15 V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 202: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

202

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.97. Raw data for Positive Short-Circuit Current @ +/- 15 V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ +/- 15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -4.02E-02 -3.92E-02 -3.87E-02 -3.82E-02 -3.75E-02 -3.79E-02 -3.80E-02879 -3.59E-02 -3.49E-02 -3.44E-02 -3.36E-02 -3.34E-02 -3.42E-02 -3.45E-02882 -4.07E-02 -3.98E-02 -3.92E-02 -3.87E-02 -3.82E-02 -3.84E-02 -3.87E-02883 -3.33E-02 -3.20E-02 -3.14E-02 -3.10E-02 -3.01E-02 -3.05E-02 -3.09E-02885 -3.56E-02 -3.45E-02 -3.39E-02 -3.40E-02 -3.28E-02 -3.32E-02 -3.35E-02886 -3.96E-02 -3.89E-02 -3.85E-02 -3.81E-02 -3.75E-02 -3.74E-02 -3.83E-02887 -3.53E-02 -3.46E-02 -3.42E-02 -3.37E-02 -3.29E-02 -3.29E-02 -3.40E-02891 -3.93E-02 -3.86E-02 -3.82E-02 -3.78E-02 -3.72E-02 -3.71E-02 -3.79E-02892 -3.43E-02 -3.38E-02 -3.34E-02 -3.30E-02 -3.23E-02 -3.22E-02 -3.32E-02895 -3.85E-02 -3.79E-02 -3.74E-02 -3.70E-02 -3.63E-02 -3.63E-02 -3.72E-02896 -3.93E-02 -3.78E-02 -3.78E-02 -3.78E-02 -3.80E-02 -3.79E-02 -3.78E-02

Biased StatisticsAverage Biased -3.72E-02 -3.61E-02 -3.55E-02 -3.51E-02 -3.44E-02 -3.48E-02 -3.51E-02Std Dev Biased 3.20E-03 3.32E-03 3.31E-03 3.29E-03 3.38E-03 3.31E-03 3.25E-03Ps90%/90% (+KTL) Biased -2.84E-02 -2.70E-02 -2.64E-02 -2.61E-02 -2.51E-02 -2.57E-02 -2.62E-02Ps90%/90% (-KTL) Biased -4.59E-02 -4.52E-02 -4.46E-02 -4.41E-02 -4.37E-02 -4.39E-02 -4.40E-02Un-Biased StatisticsAverage Un-Biased -3.74E-02 -3.68E-02 -3.64E-02 -3.59E-02 -3.52E-02 -3.52E-02 -3.61E-02Std Dev Un-Biased 2.42E-03 2.36E-03 2.38E-03 2.40E-03 2.45E-03 2.44E-03 2.33E-03Ps90%/90% (+KTL) Un-Biased -3.08E-02 -3.03E-02 -2.98E-02 -2.93E-02 -2.85E-02 -2.85E-02 -2.97E-02Ps90%/90% (-KTL) Un-Biased -4.40E-02 -4.32E-02 -4.29E-02 -4.25E-02 -4.19E-02 -4.19E-02 -4.25E-02Specification MAX -1.50E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 203: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

203

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E-02

-3.50E-02

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

+/-

15 V

#4

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.98. Plot of Positive Short-Circuit Current @ +/- 15 V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 204: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

204

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.98. Raw data for Positive Short-Circuit Current @ +/- 15 V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ +/- 15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.69E-02 -3.60E-02 -3.55E-02 -3.50E-02 -3.44E-02 -3.47E-02 -3.48E-02879 -3.54E-02 -3.44E-02 -3.41E-02 -3.34E-02 -3.32E-02 -3.40E-02 -3.42E-02882 -3.78E-02 -3.69E-02 -3.63E-02 -3.58E-02 -3.52E-02 -3.55E-02 -3.58E-02883 -3.48E-02 -3.37E-02 -3.31E-02 -3.27E-02 -3.19E-02 -3.23E-02 -3.27E-02885 -3.74E-02 -3.64E-02 -3.58E-02 -3.59E-02 -3.47E-02 -3.51E-02 -3.55E-02886 -3.79E-02 -3.73E-02 -3.69E-02 -3.64E-02 -3.58E-02 -3.58E-02 -3.67E-02887 -3.66E-02 -3.60E-02 -3.56E-02 -3.51E-02 -3.45E-02 -3.45E-02 -3.54E-02891 -3.53E-02 -3.47E-02 -3.44E-02 -3.40E-02 -3.34E-02 -3.33E-02 -3.41E-02892 -3.48E-02 -3.42E-02 -3.39E-02 -3.33E-02 -3.25E-02 -3.25E-02 -3.37E-02895 -3.53E-02 -3.46E-02 -3.42E-02 -3.38E-02 -3.30E-02 -3.31E-02 -3.40E-02896 -3.88E-02 -3.74E-02 -3.74E-02 -3.74E-02 -3.76E-02 -3.74E-02 -3.74E-02

Biased StatisticsAverage Biased -3.65E-02 -3.55E-02 -3.50E-02 -3.45E-02 -3.39E-02 -3.43E-02 -3.46E-02Std Dev Biased 1.31E-03 1.38E-03 1.32E-03 1.43E-03 1.30E-03 1.26E-03 1.24E-03Ps90%/90% (+KTL) Biased -3.29E-02 -3.17E-02 -3.13E-02 -3.06E-02 -3.03E-02 -3.09E-02 -3.12E-02Ps90%/90% (-KTL) Biased -4.01E-02 -3.93E-02 -3.86E-02 -3.85E-02 -3.74E-02 -3.78E-02 -3.80E-02Un-Biased StatisticsAverage Un-Biased -3.60E-02 -3.54E-02 -3.50E-02 -3.45E-02 -3.39E-02 -3.39E-02 -3.48E-02Std Dev Un-Biased 1.28E-03 1.24E-03 1.24E-03 1.26E-03 1.32E-03 1.31E-03 1.25E-03Ps90%/90% (+KTL) Un-Biased -3.25E-02 -3.19E-02 -3.16E-02 -3.11E-02 -3.02E-02 -3.03E-02 -3.13E-02Ps90%/90% (-KTL) Un-Biased -3.95E-02 -3.88E-02 -3.84E-02 -3.80E-02 -3.75E-02 -3.74E-02 -3.82E-02Specification MAX -1.50E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02 -1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 205: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

205

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ +

/- 15

V #

1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.99. Plot of Negative Short-Circuit Current @ +/- 15 V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 206: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

206

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.99. Raw data for Negative Short-Circuit Current @ +/- 15 V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ +/- 15 V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 5.02E-02 4.99E-02 4.95E-02 4.95E-02 4.91E-02 4.93E-02 4.96E-02879 5.00E-02 4.98E-02 4.94E-02 4.95E-02 4.95E-02 4.94E-02 4.96E-02882 5.05E-02 5.03E-02 5.00E-02 4.99E-02 4.96E-02 4.98E-02 4.98E-02883 4.86E-02 4.85E-02 4.83E-02 4.82E-02 4.79E-02 4.81E-02 4.81E-02885 5.16E-02 5.15E-02 5.12E-02 5.13E-02 5.09E-02 5.11E-02 5.10E-02886 5.04E-02 5.06E-02 5.04E-02 5.03E-02 5.00E-02 5.03E-02 5.02E-02887 5.01E-02 5.03E-02 5.00E-02 5.00E-02 4.97E-02 5.00E-02 4.99E-02891 4.96E-02 4.98E-02 4.95E-02 4.94E-02 4.91E-02 4.95E-02 4.95E-02892 4.89E-02 4.87E-02 4.84E-02 4.83E-02 4.80E-02 4.83E-02 4.83E-02895 4.92E-02 4.93E-02 4.90E-02 4.89E-02 4.87E-02 4.89E-02 4.90E-02896 4.88E-02 5.09E-02 5.09E-02 5.09E-02 5.07E-02 5.09E-02 5.09E-02

Biased StatisticsAverage Biased 5.02E-02 5.00E-02 4.97E-02 4.97E-02 4.94E-02 4.95E-02 4.96E-02Std Dev Biased 1.06E-03 1.07E-03 1.08E-03 1.13E-03 1.08E-03 1.09E-03 1.05E-03Ps90%/90% (+KTL) Biased 5.31E-02 5.29E-02 5.26E-02 5.28E-02 5.23E-02 5.25E-02 5.25E-02Ps90%/90% (-KTL) Biased 4.72E-02 4.70E-02 4.67E-02 4.66E-02 4.64E-02 4.66E-02 4.67E-02Un-Biased StatisticsAverage Un-Biased 4.96E-02 4.97E-02 4.95E-02 4.94E-02 4.91E-02 4.94E-02 4.94E-02Std Dev Un-Biased 6.15E-04 7.61E-04 7.92E-04 8.14E-04 8.06E-04 8.07E-04 7.47E-04Ps90%/90% (+KTL) Un-Biased 5.13E-02 5.18E-02 5.16E-02 5.16E-02 5.13E-02 5.16E-02 5.14E-02Ps90%/90% (-KTL) Un-Biased 4.80E-02 4.76E-02 4.73E-02 4.72E-02 4.69E-02 4.72E-02 4.73E-02Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 207: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

207

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ +

/- 15

V #

2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.100. Plot of Negative Short-Circuit Current @ +/- 15 V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 208: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

208

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.100. Raw data for Negative Short-Circuit Current @ +/- 15 V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ +/- 15 V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.98E-02 4.95E-02 4.92E-02 4.92E-02 4.88E-02 4.90E-02 4.93E-02879 4.84E-02 4.81E-02 4.77E-02 4.77E-02 4.78E-02 4.77E-02 4.79E-02882 5.05E-02 5.03E-02 5.00E-02 5.00E-02 4.97E-02 4.99E-02 4.99E-02883 4.78E-02 4.77E-02 4.77E-02 4.75E-02 4.72E-02 4.75E-02 4.74E-02885 4.78E-02 4.77E-02 4.77E-02 4.75E-02 4.73E-02 4.75E-02 4.75E-02886 4.98E-02 5.00E-02 4.98E-02 4.97E-02 4.94E-02 4.98E-02 4.96E-02887 4.81E-02 4.82E-02 4.79E-02 4.79E-02 4.75E-02 4.79E-02 4.79E-02891 4.93E-02 4.95E-02 4.92E-02 4.92E-02 4.88E-02 4.92E-02 4.93E-02892 4.79E-02 4.77E-02 4.77E-02 4.76E-02 4.73E-02 4.77E-02 4.76E-02895 5.03E-02 5.04E-02 5.02E-02 5.01E-02 4.99E-02 5.01E-02 5.01E-02896 4.81E-02 5.01E-02 5.01E-02 5.00E-02 4.99E-02 5.01E-02 5.01E-02

Biased StatisticsAverage Biased 4.89E-02 4.87E-02 4.85E-02 4.84E-02 4.81E-02 4.83E-02 4.84E-02Std Dev Biased 1.23E-03 1.17E-03 1.11E-03 1.12E-03 1.08E-03 1.10E-03 1.14E-03Ps90%/90% (+KTL) Biased 5.22E-02 5.19E-02 5.15E-02 5.14E-02 5.11E-02 5.13E-02 5.15E-02Ps90%/90% (-KTL) Biased 4.55E-02 4.55E-02 4.54E-02 4.53E-02 4.52E-02 4.53E-02 4.53E-02Un-Biased StatisticsAverage Un-Biased 4.91E-02 4.92E-02 4.90E-02 4.89E-02 4.86E-02 4.89E-02 4.89E-02Std Dev Un-Biased 1.02E-03 1.16E-03 1.11E-03 1.12E-03 1.14E-03 1.11E-03 1.10E-03Ps90%/90% (+KTL) Un-Biased 5.19E-02 5.23E-02 5.20E-02 5.19E-02 5.17E-02 5.20E-02 5.19E-02Ps90%/90% (-KTL) Un-Biased 4.63E-02 4.60E-02 4.59E-02 4.58E-02 4.55E-02 4.59E-02 4.59E-02Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 209: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

209

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ +

/- 15

V #

3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.101. Plot of Negative Short-Circuit Current @ +/- 15 V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 210: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

210

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.101. Raw data for Negative Short-Circuit Current @ +/- 15 V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ +/- 15 V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.99E-02 4.96E-02 4.93E-02 4.93E-02 4.88E-02 4.91E-02 4.94E-02879 4.85E-02 4.83E-02 4.79E-02 4.79E-02 4.79E-02 4.78E-02 4.80E-02882 5.07E-02 5.05E-02 5.03E-02 5.01E-02 4.99E-02 5.01E-02 5.01E-02883 4.82E-02 4.81E-02 4.78E-02 4.77E-02 4.75E-02 4.76E-02 4.76E-02885 4.80E-02 4.78E-02 4.77E-02 4.77E-02 4.74E-02 4.76E-02 4.76E-02886 4.98E-02 5.00E-02 4.98E-02 4.98E-02 4.95E-02 4.98E-02 4.96E-02887 4.82E-02 4.83E-02 4.81E-02 4.80E-02 4.76E-02 4.80E-02 4.80E-02891 4.92E-02 4.93E-02 4.90E-02 4.89E-02 4.87E-02 4.90E-02 4.91E-02892 4.80E-02 4.78E-02 4.76E-02 4.76E-02 4.73E-02 4.76E-02 4.77E-02895 5.04E-02 5.05E-02 5.03E-02 5.02E-02 4.99E-02 5.02E-02 5.02E-02896 4.83E-02 5.03E-02 5.02E-02 5.02E-02 5.00E-02 5.02E-02 5.02E-02

Biased StatisticsAverage Biased 4.90E-02 4.88E-02 4.86E-02 4.85E-02 4.83E-02 4.84E-02 4.85E-02Std Dev Biased 1.18E-03 1.15E-03 1.13E-03 1.12E-03 1.04E-03 1.10E-03 1.15E-03Ps90%/90% (+KTL) Biased 5.23E-02 5.20E-02 5.17E-02 5.16E-02 5.12E-02 5.14E-02 5.17E-02Ps90%/90% (-KTL) Biased 4.58E-02 4.57E-02 4.55E-02 4.55E-02 4.55E-02 4.54E-02 4.54E-02Un-Biased StatisticsAverage Un-Biased 4.91E-02 4.92E-02 4.89E-02 4.89E-02 4.86E-02 4.89E-02 4.89E-02Std Dev Un-Biased 1.00E-03 1.14E-03 1.12E-03 1.11E-03 1.12E-03 1.13E-03 1.09E-03Ps90%/90% (+KTL) Un-Biased 5.19E-02 5.23E-02 5.20E-02 5.19E-02 5.17E-02 5.20E-02 5.19E-02Ps90%/90% (-KTL) Un-Biased 4.64E-02 4.61E-02 4.59E-02 4.59E-02 4.55E-02 4.58E-02 4.59E-02Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 211: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

211

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ +

/- 15

V #

4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.102. Plot of Negative Short-Circuit Current @ +/- 15 V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 212: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

212

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.102. Raw data for Negative Short-Circuit Current @ +/- 15 V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ +/- 15 V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.85E-02 4.83E-02 4.80E-02 4.79E-02 4.75E-02 4.77E-02 4.80E-02879 4.82E-02 4.81E-02 4.77E-02 4.78E-02 4.78E-02 4.78E-02 4.79E-02882 4.88E-02 4.86E-02 4.83E-02 4.82E-02 4.80E-02 4.81E-02 4.82E-02883 4.72E-02 4.71E-02 4.69E-02 4.68E-02 4.65E-02 4.67E-02 4.67E-02885 5.02E-02 5.01E-02 4.98E-02 4.99E-02 4.95E-02 4.97E-02 4.97E-02886 4.87E-02 4.89E-02 4.87E-02 4.87E-02 4.84E-02 4.87E-02 4.86E-02887 4.85E-02 4.86E-02 4.84E-02 4.83E-02 4.80E-02 4.83E-02 4.82E-02891 4.80E-02 4.81E-02 4.78E-02 4.78E-02 4.75E-02 4.78E-02 4.79E-02892 4.76E-02 4.73E-02 4.71E-02 4.70E-02 4.67E-02 4.70E-02 4.70E-02895 4.75E-02 4.76E-02 4.75E-02 4.75E-02 4.72E-02 4.75E-02 4.75E-02896 4.75E-02 4.92E-02 4.91E-02 4.91E-02 4.89E-02 4.91E-02 4.91E-02

Biased StatisticsAverage Biased 4.86E-02 4.84E-02 4.81E-02 4.81E-02 4.78E-02 4.80E-02 4.81E-02Std Dev Biased 1.07E-03 1.08E-03 1.09E-03 1.13E-03 1.07E-03 1.09E-03 1.07E-03Ps90%/90% (+KTL) Biased 5.15E-02 5.14E-02 5.11E-02 5.12E-02 5.08E-02 5.10E-02 5.10E-02Ps90%/90% (-KTL) Biased 4.57E-02 4.55E-02 4.52E-02 4.50E-02 4.49E-02 4.50E-02 4.51E-02Un-Biased StatisticsAverage Un-Biased 4.80E-02 4.81E-02 4.79E-02 4.78E-02 4.75E-02 4.79E-02 4.78E-02Std Dev Un-Biased 5.42E-04 6.70E-04 6.62E-04 6.65E-04 6.77E-04 6.67E-04 6.11E-04Ps90%/90% (+KTL) Un-Biased 4.95E-02 4.99E-02 4.97E-02 4.97E-02 4.94E-02 4.97E-02 4.95E-02Ps90%/90% (-KTL) Un-Biased 4.66E-02 4.63E-02 4.61E-02 4.60E-02 4.57E-02 4.60E-02 4.62E-02Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 213: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

213

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E-03

5.50E-03

6.00E-03

6.50E-03

7.00E-03

7.50E-03

8.00E-03

8.50E-03

9.00E-03

9.50E-03

1.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Supp

ly C

urre

nt @

3V

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.103. Plot of Positive Supply Current @ 3V (A) versus total dose. The data show no significantchange with radiation. The solid diamonds are the average of the measured data points for the sampleirradiated under electrical bias while the shaded diamonds are the average of the measured data points for theunits irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the datapoints after application of the KTL statistics on the sample irradiated under electrical bias while the gray lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 214: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

214

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.103. Raw data for Positive Supply Current @ 3V (A) versus total dose, including thestatistical analysis, specification and the status of the testing (pass/fail).

Positive Supply Current @ 3V (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.52E-03 7.42E-03 7.32E-03 7.25E-03 6.84E-03 6.90E-03 7.26E-03879 7.54E-03 7.21E-03 7.09E-03 6.98E-03 7.10E-03 7.12E-03 7.17E-03882 7.57E-03 7.49E-03 7.38E-03 7.30E-03 6.94E-03 6.96E-03 7.34E-03883 7.43E-03 7.30E-03 7.19E-03 7.11E-03 6.70E-03 6.77E-03 7.14E-03885 7.44E-03 7.33E-03 7.22E-03 7.31E-03 7.02E-03 7.10E-03 7.21E-03886 7.40E-03 7.35E-03 7.33E-03 7.32E-03 7.27E-03 7.25E-03 7.31E-03887 7.40E-03 7.35E-03 7.32E-03 7.30E-03 7.24E-03 7.22E-03 7.30E-03891 7.47E-03 7.43E-03 7.41E-03 7.39E-03 7.34E-03 7.32E-03 7.38E-03892 7.31E-03 7.26E-03 7.23E-03 7.19E-03 7.13E-03 7.12E-03 7.20E-03895 7.51E-03 7.47E-03 7.45E-03 7.42E-03 7.36E-03 7.34E-03 7.42E-03896 7.76E-03 7.75E-03 7.75E-03 7.76E-03 7.76E-03 7.73E-03 7.75E-03

Biased StatisticsAverage Biased 7.50E-03 7.35E-03 7.24E-03 7.19E-03 6.92E-03 6.97E-03 7.22E-03Std Dev Biased 6.20E-05 1.08E-04 1.13E-04 1.42E-04 1.56E-04 1.45E-04 7.89E-05Ps90%/90% (+KTL) Biased 7.67E-03 7.65E-03 7.55E-03 7.58E-03 7.35E-03 7.37E-03 7.44E-03Ps90%/90% (-KTL) Biased 7.33E-03 7.05E-03 6.93E-03 6.80E-03 6.49E-03 6.57E-03 7.01E-03Un-Biased StatisticsAverage Un-Biased 7.42E-03 7.37E-03 7.35E-03 7.32E-03 7.27E-03 7.25E-03 7.32E-03Std Dev Un-Biased 7.66E-05 8.14E-05 8.56E-05 8.96E-05 9.15E-05 8.77E-05 8.44E-05Ps90%/90% (+KTL) Un-Biased 7.63E-03 7.60E-03 7.58E-03 7.57E-03 7.52E-03 7.49E-03 7.55E-03Ps90%/90% (-KTL) Un-Biased 7.21E-03 7.15E-03 7.11E-03 7.08E-03 7.02E-03 7.01E-03 7.09E-03Specification MAX 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 215: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

215

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-02

-9.50E-03

-9.00E-03

-8.50E-03

-8.00E-03

-7.50E-03

-7.00E-03

-6.50E-03

-6.00E-03

-5.50E-03

-5.00E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Su

pply

Cur

rent

@ 3

V (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.104. Plot of Negative Supply Current @ 3V (A) versus total dose. The data show no significantchange with radiation. The solid diamonds are the average of the measured data points for the sampleirradiated under electrical bias while the shaded diamonds are the average of the measured data points for theunits irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the datapoints after application of the KTL statistics on the sample irradiated under electrical bias while the gray lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 216: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

216

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.104. Raw data for Negative Supply Current @ 3V (A) versus total dose, including thestatistical analysis, specification and the status of the testing (pass/fail).

Negative Supply Current @ 3V (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -7.52E-03 -7.42E-03 -7.31E-03 -7.25E-03 -6.84E-03 -6.90E-03 -7.25E-03879 -7.53E-03 -7.20E-03 -7.08E-03 -6.98E-03 -7.09E-03 -7.11E-03 -7.17E-03882 -7.57E-03 -7.48E-03 -7.38E-03 -7.29E-03 -6.94E-03 -6.95E-03 -7.33E-03883 -7.42E-03 -7.29E-03 -7.18E-03 -7.11E-03 -6.70E-03 -6.77E-03 -7.13E-03885 -7.44E-03 -7.32E-03 -7.21E-03 -7.30E-03 -7.01E-03 -7.10E-03 -7.21E-03886 -7.39E-03 -7.35E-03 -7.33E-03 -7.31E-03 -7.27E-03 -7.24E-03 -7.30E-03887 -7.40E-03 -7.35E-03 -7.32E-03 -7.30E-03 -7.24E-03 -7.22E-03 -7.29E-03891 -7.47E-03 -7.42E-03 -7.41E-03 -7.38E-03 -7.34E-03 -7.31E-03 -7.37E-03892 -7.30E-03 -7.26E-03 -7.23E-03 -7.19E-03 -7.12E-03 -7.11E-03 -7.19E-03895 -7.50E-03 -7.46E-03 -7.44E-03 -7.42E-03 -7.36E-03 -7.34E-03 -7.41E-03896 -7.75E-03 -7.74E-03 -7.75E-03 -7.76E-03 -7.76E-03 -7.73E-03 -7.75E-03

Biased StatisticsAverage Biased -7.50E-03 -7.34E-03 -7.23E-03 -7.19E-03 -6.92E-03 -6.97E-03 -7.22E-03Std Dev Biased 6.35E-05 1.10E-04 1.16E-04 1.38E-04 1.52E-04 1.43E-04 7.69E-05Ps90%/90% (+KTL) Biased -7.32E-03 -7.04E-03 -6.91E-03 -6.81E-03 -6.50E-03 -6.57E-03 -7.01E-03Ps90%/90% (-KTL) Biased -7.67E-03 -7.64E-03 -7.55E-03 -7.56E-03 -7.33E-03 -7.36E-03 -7.43E-03Un-Biased StatisticsAverage Un-Biased -7.41E-03 -7.37E-03 -7.35E-03 -7.32E-03 -7.27E-03 -7.24E-03 -7.31E-03Std Dev Un-Biased 7.79E-05 7.66E-05 8.26E-05 8.80E-05 9.53E-05 8.96E-05 8.44E-05Ps90%/90% (+KTL) Un-Biased -7.20E-03 -7.16E-03 -7.12E-03 -7.08E-03 -7.00E-03 -7.00E-03 -7.08E-03Ps90%/90% (-KTL) Un-Biased -7.63E-03 -7.58E-03 -7.57E-03 -7.56E-03 -7.53E-03 -7.49E-03 -7.54E-03Specification MIN -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 217: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

217

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=0

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.105. Plot of Input Offset Voltage @ 3V, VCM=0V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 218: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

218

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.105. Raw data for Input Offset Voltage @ 3V, VCM=0V #1 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=0V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.95E-04 -3.08E-04 -2.97E-04 -2.91E-04 -2.76E-04 -2.84E-04 -3.14E-04879 -2.97E-04 7.32E-05 8.33E-05 6.95E-05 6.42E-05 5.75E-05 6.94E-05882 -6.53E-05 -7.28E-05 -6.72E-05 -7.06E-05 -5.66E-05 -6.00E-05 -8.02E-05883 3.42E-05 1.82E-05 2.43E-05 3.78E-05 3.65E-05 2.63E-05 8.97E-06885 -2.26E-04 -2.45E-04 -2.37E-04 -2.43E-04 -2.33E-04 -2.38E-04 -2.54E-04886 1.77E-04 1.55E-04 1.51E-04 1.47E-04 1.40E-04 1.35E-04 1.34E-04887 -2.03E-04 -2.15E-04 -2.19E-04 -2.24E-04 -2.33E-04 -2.34E-04 -2.31E-04891 -5.87E-06 -2.35E-05 -2.65E-05 -3.29E-05 -3.87E-05 -4.61E-05 -4.67E-05892 -2.31E-04 -2.44E-04 -2.49E-04 -2.57E-04 -2.62E-04 -2.60E-04 -2.60E-04895 -9.34E-05 -1.10E-04 -1.15E-04 -1.19E-04 -1.32E-04 -1.36E-04 -1.22E-04896 1.44E-04 1.42E-04 1.42E-04 1.45E-04 1.44E-04 1.41E-04 1.43E-04

Biased StatisticsAverage Biased -1.70E-04 -1.07E-04 -9.88E-05 -9.94E-05 -9.29E-05 -9.96E-05 -1.14E-04Std Dev Biased 1.48E-04 1.65E-04 1.64E-04 1.62E-04 1.55E-04 1.54E-04 1.65E-04Ps90%/90% (+KTL) Biased 2.36E-04 3.45E-04 3.51E-04 3.46E-04 3.31E-04 3.24E-04 3.40E-04Ps90%/90% (-KTL) Biased -5.75E-04 -5.59E-04 -5.49E-04 -5.45E-04 -5.17E-04 -5.23E-04 -5.67E-04Un-Biased StatisticsAverage Un-Biased -7.12E-05 -8.75E-05 -9.17E-05 -9.73E-05 -1.05E-04 -1.08E-04 -1.05E-04Std Dev Un-Biased 1.65E-04 1.62E-04 1.62E-04 1.63E-04 1.63E-04 1.60E-04 1.59E-04Ps90%/90% (+KTL) Un-Biased 3.81E-04 3.55E-04 3.52E-04 3.49E-04 3.42E-04 3.31E-04 3.29E-04Ps90%/90% (-KTL) Un-Biased -5.24E-04 -5.30E-04 -5.35E-04 -5.43E-04 -5.52E-04 -5.48E-04 -5.40E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 219: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

219

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=0

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.106. Plot of Input Offset Voltage @ 3V, VCM=0V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 220: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

220

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.106. Raw data for Input Offset Voltage @ 3V, VCM=0V #2 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=0V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.32E-04 -2.50E-04 -2.46E-04 -2.10E-04 -1.65E-04 -2.14E-04 -2.60E-04879 -2.30E-04 -5.13E-05 -3.32E-05 -4.31E-05 -5.55E-05 -5.37E-05 -5.40E-05882 1.21E-04 9.92E-05 9.41E-05 9.62E-05 1.12E-04 1.02E-04 8.24E-05883 -7.01E-05 -9.01E-05 -7.71E-05 -5.89E-05 -6.42E-05 -2.93E-05 -8.75E-05885 -2.33E-05 -2.62E-05 -3.46E-06 -1.94E-05 -2.27E-05 -3.57E-05 -3.96E-05886 2.02E-04 1.81E-04 1.75E-04 1.73E-04 1.68E-04 1.62E-04 1.70E-04887 -1.62E-04 -1.64E-04 -1.67E-04 -1.71E-04 -1.79E-04 -1.85E-04 -1.95E-04891 2.90E-04 2.82E-04 2.79E-04 2.74E-04 2.67E-04 2.61E-04 2.75E-04892 1.32E-04 1.20E-04 1.17E-04 1.13E-04 1.05E-04 1.04E-04 9.20E-05895 1.73E-05 4.74E-06 1.85E-06 -9.30E-07 -2.98E-06 -7.94E-06 -1.39E-05896 1.40E-04 1.41E-04 1.41E-04 1.43E-04 1.42E-04 1.39E-04 1.40E-04

Biased StatisticsAverage Biased -8.67E-05 -6.37E-05 -5.31E-05 -4.70E-05 -3.90E-05 -4.62E-05 -7.17E-05Std Dev Biased 1.49E-04 1.26E-04 1.25E-04 1.09E-04 9.99E-05 1.12E-04 1.23E-04Ps90%/90% (+KTL) Biased 3.22E-04 2.82E-04 2.89E-04 2.53E-04 2.35E-04 2.62E-04 2.66E-04Ps90%/90% (-KTL) Biased -4.96E-04 -4.09E-04 -3.95E-04 -3.47E-04 -3.13E-04 -3.54E-04 -4.10E-04Un-Biased StatisticsAverage Un-Biased 9.57E-05 8.48E-05 8.11E-05 7.74E-05 7.14E-05 6.70E-05 6.56E-05Std Dev Un-Biased 1.75E-04 1.71E-04 1.71E-04 1.71E-04 1.71E-04 1.71E-04 1.80E-04Ps90%/90% (+KTL) Un-Biased 5.76E-04 5.55E-04 5.50E-04 5.46E-04 5.40E-04 5.37E-04 5.59E-04Ps90%/90% (-KTL) Un-Biased -3.84E-04 -3.85E-04 -3.88E-04 -3.91E-04 -3.97E-04 -4.03E-04 -4.28E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 221: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

221

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=0

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.107. Plot of Input Offset Voltage @ 3V, VCM=0V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 222: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

222

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.107. Raw data for Input Offset Voltage @ 3V, VCM=0V #3 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=0V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.86E-05 1.07E-05 1.73E-05 2.58E-05 2.21E-05 2.01E-05 2.93E-06879 4.02E-05 1.58E-04 1.72E-04 1.58E-04 1.51E-04 1.46E-04 1.52E-04882 -1.07E-04 -1.36E-04 -1.28E-04 -1.26E-04 -1.11E-04 -1.26E-04 -1.47E-04883 1.54E-04 1.28E-04 1.27E-04 1.43E-04 1.37E-04 1.33E-04 9.24E-05885 -1.84E-04 -1.99E-04 -1.95E-04 -1.96E-04 -2.01E-04 -2.05E-04 -2.27E-04886 -3.35E-04 -3.49E-04 -3.55E-04 -3.58E-04 -3.64E-04 -3.62E-04 -3.63E-04887 -1.06E-04 -1.11E-04 -1.20E-04 -1.28E-04 -1.46E-04 -1.53E-04 -1.25E-04891 -2.73E-05 -3.62E-05 -3.85E-05 -4.56E-05 -4.90E-05 -5.12E-05 -5.41E-05892 1.43E-05 3.29E-06 -3.20E-07 -5.04E-06 -8.05E-06 -1.05E-05 -9.87E-06895 -2.99E-05 -4.53E-05 -4.86E-05 -4.96E-05 -5.21E-05 -5.78E-05 -4.96E-05896 3.49E-04 3.44E-04 3.46E-04 3.48E-04 3.48E-04 3.42E-04 3.47E-04

Biased StatisticsAverage Biased -1.17E-05 -7.85E-06 -1.15E-06 1.17E-06 -6.14E-07 -6.29E-06 -2.52E-05Std Dev Biased 1.33E-04 1.58E-04 1.58E-04 1.58E-04 1.54E-04 1.56E-04 1.59E-04Ps90%/90% (+KTL) Biased 3.54E-04 4.24E-04 4.33E-04 4.35E-04 4.21E-04 4.20E-04 4.11E-04Ps90%/90% (-KTL) Biased -3.77E-04 -4.40E-04 -4.36E-04 -4.33E-04 -4.22E-04 -4.33E-04 -4.62E-04Un-Biased StatisticsAverage Un-Biased -9.68E-05 -1.08E-04 -1.13E-04 -1.17E-04 -1.24E-04 -1.27E-04 -1.20E-04Std Dev Un-Biased 1.40E-04 1.41E-04 1.42E-04 1.42E-04 1.43E-04 1.42E-04 1.42E-04Ps90%/90% (+KTL) Un-Biased 2.88E-04 2.79E-04 2.78E-04 2.72E-04 2.70E-04 2.61E-04 2.69E-04Ps90%/90% (-KTL) Un-Biased -4.81E-04 -4.94E-04 -5.03E-04 -5.07E-04 -5.17E-04 -5.15E-04 -5.10E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 223: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

223

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=0

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.108. Plot of Input Offset Voltage @ 3V, VCM=0V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 224: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

224

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.108. Raw data for Input Offset Voltage @ 3V, VCM=0V #4 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=0V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.77E-04 -2.98E-04 -2.86E-04 -2.83E-04 -2.65E-04 -2.70E-04 -2.89E-04879 -2.75E-04 1.68E-04 1.78E-04 1.67E-04 1.64E-04 1.63E-04 1.46E-04882 -2.03E-04 -2.27E-04 -2.14E-04 -2.09E-04 -2.05E-04 -2.09E-04 -2.23E-04883 -4.83E-05 -6.42E-05 -5.79E-05 -3.21E-05 -5.54E-05 -5.31E-05 -7.65E-05885 5.16E-05 2.48E-05 2.73E-05 3.06E-05 2.06E-05 1.70E-05 -1.29E-05886 1.77E-04 1.58E-04 1.48E-04 1.45E-04 1.40E-04 1.32E-04 1.37E-04887 -2.29E-04 -2.46E-04 -2.48E-04 -2.50E-04 -2.59E-04 -2.61E-04 -2.57E-04891 1.30E-04 1.14E-04 1.09E-04 1.05E-04 1.00E-04 9.47E-05 9.91E-05892 1.91E-04 1.90E-04 1.86E-04 1.92E-04 1.83E-04 1.80E-04 1.89E-04895 1.74E-04 1.57E-04 1.51E-04 1.44E-04 1.31E-04 1.23E-04 1.34E-04896 1.08E-04 1.05E-04 1.04E-04 1.02E-04 1.06E-04 9.96E-05 1.07E-04

Biased StatisticsAverage Biased -1.50E-04 -7.94E-05 -7.04E-05 -6.53E-05 -6.80E-05 -7.04E-05 -9.10E-05Std Dev Biased 1.46E-04 1.88E-04 1.86E-04 1.82E-04 1.73E-04 1.74E-04 1.73E-04Ps90%/90% (+KTL) Biased 2.51E-04 4.37E-04 4.40E-04 4.34E-04 4.06E-04 4.07E-04 3.82E-04Ps90%/90% (-KTL) Biased -5.52E-04 -5.96E-04 -5.81E-04 -5.64E-04 -5.42E-04 -5.48E-04 -5.64E-04Un-Biased StatisticsAverage Un-Biased 8.87E-05 7.45E-05 6.92E-05 6.73E-05 5.92E-05 5.39E-05 6.06E-05Std Dev Un-Biased 1.79E-04 1.81E-04 1.79E-04 1.80E-04 1.80E-04 1.79E-04 1.80E-04Ps90%/90% (+KTL) Un-Biased 5.79E-04 5.71E-04 5.61E-04 5.61E-04 5.54E-04 5.44E-04 5.55E-04Ps90%/90% (-KTL) Un-Biased -4.02E-04 -4.22E-04 -4.23E-04 -4.26E-04 -4.35E-04 -4.36E-04 -4.34E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 225: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

225

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=0

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.109. Plot of Input Offset Current @ 3V, VCM=0V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 226: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

226

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.109. Raw data for Input Offset Current @ 3V, VCM=0V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=0V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 9.30E-10 8.13E-10 1.11E-09 1.16E-09 3.49E-10 4.73E-10 6.65E-10879 8.59E-10 1.03E-09 1.09E-09 7.10E-10 2.90E-09 2.08E-09 1.84E-09882 -4.01E-09 -4.28E-09 -3.92E-09 -4.44E-09 -4.11E-09 -3.58E-09 -3.86E-09883 -2.14E-09 -1.76E-09 -1.41E-09 -1.56E-09 -2.39E-09 -2.27E-09 -2.23E-09885 -2.33E-09 -3.02E-09 -2.63E-09 -1.01E-09 -1.45E-09 -2.36E-09 -2.28E-09886 4.75E-09 4.46E-09 3.55E-09 3.81E-09 4.05E-09 3.97E-09 3.79E-09887 2.80E-09 2.92E-09 2.39E-09 1.99E-09 2.34E-09 2.31E-09 2.45E-09891 -3.40E-10 -3.90E-10 -5.87E-10 -7.00E-12 -5.00E-12 -5.12E-10 -2.99E-09892 -2.51E-09 -2.85E-09 -2.75E-09 -2.53E-09 -2.60E-09 -3.09E-09 -2.45E-09895 1.07E-09 1.17E-09 1.63E-09 1.80E-09 1.87E-09 2.05E-09 1.79E-09896 8.51E-10 8.06E-10 8.15E-10 8.32E-10 8.95E-10 8.97E-10 8.92E-10

Biased StatisticsAverage Biased -1.34E-09 -1.44E-09 -1.15E-09 -1.03E-09 -9.40E-10 -1.13E-09 -1.17E-09Std Dev Biased 2.17E-09 2.34E-09 2.24E-09 2.22E-09 2.69E-09 2.33E-09 2.35E-09Ps90%/90% (+KTL) Biased 4.60E-09 4.96E-09 5.00E-09 5.06E-09 6.42E-09 5.25E-09 5.26E-09Ps90%/90% (-KTL) Biased -7.28E-09 -7.85E-09 -7.30E-09 -7.12E-09 -8.30E-09 -7.51E-09 -7.61E-09Un-Biased StatisticsAverage Un-Biased 1.15E-09 1.06E-09 8.48E-10 1.01E-09 1.13E-09 9.47E-10 5.17E-10Std Dev Un-Biased 2.80E-09 2.85E-09 2.52E-09 2.40E-09 2.54E-09 2.77E-09 3.05E-09Ps90%/90% (+KTL) Un-Biased 8.83E-09 8.87E-09 7.75E-09 7.59E-09 8.09E-09 8.53E-09 8.87E-09Ps90%/90% (-KTL) Un-Biased -6.52E-09 -6.74E-09 -6.05E-09 -5.57E-09 -5.82E-09 -6.64E-09 -7.84E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 227: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

227

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=0

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.110. Plot of Input Offset Current @ 3V, VCM=0V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 228: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

228

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.110. Raw data for Input Offset Current @ 3V, VCM=0V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=0V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -8.63E-10 -1.33E-09 -1.15E-09 2.04E-09 5.71E-09 -6.91E-10 -5.58E-10879 -8.08E-10 -6.99E-09 -6.64E-09 -6.06E-09 -4.92E-09 -5.19E-09 -5.63E-09882 -3.29E-09 -3.48E-09 -3.91E-09 -3.47E-09 -3.21E-09 -3.86E-09 -3.60E-09883 -2.32E-10 -8.90E-10 -5.20E-10 -1.59E-10 1.05E-09 7.06E-09 -3.55E-10885 7.16E-10 1.47E-09 2.70E-09 2.98E-09 4.48E-10 1.04E-09 1.14E-09886 -4.12E-10 -9.50E-11 -1.92E-10 2.88E-10 1.13E-09 1.25E-09 8.40E-11887 -6.68E-09 -6.55E-09 -6.32E-09 -6.12E-09 -6.67E-09 -6.75E-09 -6.61E-09891 6.60E-10 5.01E-10 5.22E-10 6.97E-10 1.08E-10 4.26E-10 4.32E-10892 1.94E-09 2.15E-09 2.22E-09 2.70E-09 2.20E-09 2.35E-09 2.31E-09895 3.04E-09 2.70E-09 2.49E-09 2.28E-09 2.58E-09 2.55E-09 2.35E-09896 2.38E-09 2.41E-09 2.43E-09 2.36E-09 2.37E-09 2.38E-09 2.36E-09

Biased StatisticsAverage Biased -8.95E-10 -2.24E-09 -1.90E-09 -9.32E-10 -1.88E-10 -3.29E-10 -1.80E-09Std Dev Biased 1.48E-09 3.18E-09 3.54E-09 3.79E-09 4.13E-09 4.82E-09 2.75E-09Ps90%/90% (+KTL) Biased 3.17E-09 6.49E-09 7.80E-09 9.46E-09 1.11E-08 1.29E-08 5.73E-09Ps90%/90% (-KTL) Biased -4.96E-09 -1.10E-08 -1.16E-08 -1.13E-08 -1.15E-08 -1.35E-08 -9.34E-09Un-Biased StatisticsAverage Un-Biased -2.91E-10 -2.59E-10 -2.57E-10 -3.16E-11 -1.31E-10 -3.70E-11 -2.87E-10Std Dev Un-Biased 3.80E-09 3.70E-09 3.57E-09 3.55E-09 3.78E-09 3.85E-09 3.68E-09Ps90%/90% (+KTL) Un-Biased 1.01E-08 9.89E-09 9.54E-09 9.71E-09 1.02E-08 1.05E-08 9.82E-09Ps90%/90% (-KTL) Un-Biased -1.07E-08 -1.04E-08 -1.01E-08 -9.77E-09 -1.05E-08 -1.06E-08 -1.04E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 229: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

229

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=0

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.111. Plot of Input Offset Current @ 3V, VCM=0V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 230: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

230

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.111. Raw data for Input Offset Current @ 3V, VCM=0V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=0V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 6.97E-09 7.08E-09 7.22E-09 7.19E-09 7.08E-09 6.69E-09 7.49E-09879 6.88E-09 -4.36E-09 -4.15E-09 -4.39E-09 -2.69E-09 -3.01E-09 -2.88E-09882 -1.11E-09 -1.35E-09 -1.97E-09 -2.24E-09 -2.26E-09 -2.64E-09 -1.97E-09883 3.46E-09 3.04E-09 3.32E-09 3.74E-09 2.86E-09 2.86E-09 2.94E-09885 4.70E-09 4.60E-09 4.19E-09 5.36E-09 5.00E-09 4.23E-09 5.11E-09886 9.23E-10 4.48E-10 6.97E-10 3.02E-10 1.28E-09 1.01E-09 7.46E-10887 -2.10E-09 -2.05E-09 -2.12E-09 -2.09E-09 -1.84E-09 -2.04E-09 -1.90E-09891 3.29E-09 3.06E-09 3.36E-09 3.17E-09 2.43E-09 2.88E-09 3.05E-09892 3.82E-10 9.88E-10 6.78E-10 8.75E-10 8.00E-10 7.29E-10 4.50E-10895 1.71E-09 1.35E-09 7.45E-10 1.89E-09 1.78E-09 2.26E-09 1.95E-09896 2.99E-09 2.96E-09 3.02E-09 3.00E-09 2.94E-09 2.99E-09 3.03E-09

Biased StatisticsAverage Biased 4.18E-09 1.80E-09 1.72E-09 1.93E-09 2.00E-09 1.63E-09 2.14E-09Std Dev Biased 3.31E-09 4.61E-09 4.66E-09 5.00E-09 4.35E-09 4.29E-09 4.48E-09Ps90%/90% (+KTL) Biased 1.33E-08 1.44E-08 1.45E-08 1.56E-08 1.39E-08 1.34E-08 1.44E-08Ps90%/90% (-KTL) Biased -4.89E-09 -1.08E-08 -1.11E-08 -1.18E-08 -9.92E-09 -1.01E-08 -1.01E-08Un-Biased StatisticsAverage Un-Biased 8.42E-10 7.59E-10 6.73E-10 8.30E-10 8.89E-10 9.66E-10 8.60E-10Std Dev Un-Biased 1.98E-09 1.85E-09 1.94E-09 1.96E-09 1.64E-09 1.90E-09 1.86E-09Ps90%/90% (+KTL) Un-Biased 6.26E-09 5.82E-09 5.98E-09 6.21E-09 5.39E-09 6.18E-09 5.95E-09Ps90%/90% (-KTL) Un-Biased -4.58E-09 -4.31E-09 -4.64E-09 -4.55E-09 -3.61E-09 -4.25E-09 -4.23E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 231: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

231

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=0

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.112. Plot of Input Offset Current @ 3V, VCM=0V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 232: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

232

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.112. Raw data for Input Offset Current @ 3V, VCM=0V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=0V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -4.88E-09 -5.23E-09 -4.16E-09 -4.31E-09 -4.48E-09 -4.17E-09 -4.34E-09879 -4.84E-09 -2.84E-09 -1.94E-09 -2.15E-09 -1.00E-09 -1.48E-09 -1.35E-09882 1.60E-09 1.48E-09 9.85E-10 1.27E-09 9.94E-10 1.12E-09 1.25E-09883 -3.09E-09 -3.40E-09 -3.52E-09 -1.82E-09 -2.96E-09 -2.64E-09 -3.05E-09885 8.37E-10 7.54E-10 1.11E-09 2.88E-09 1.28E-09 1.57E-09 1.34E-09886 4.55E-10 1.81E-10 4.71E-10 1.69E-10 -3.84E-10 -4.52E-10 -2.69E-10887 -2.96E-09 -3.27E-09 -3.20E-09 -3.36E-09 -3.15E-09 -2.88E-09 -3.55E-09891 -2.85E-09 -2.93E-09 -3.07E-09 -3.42E-09 -2.35E-09 -2.11E-09 -2.71E-09892 2.98E-09 2.90E-09 2.97E-09 3.32E-09 2.33E-09 2.93E-09 2.10E-09895 -3.83E-09 -4.19E-09 -3.61E-09 -3.84E-09 -3.84E-09 -4.75E-09 -4.27E-09896 5.79E-09 5.84E-09 5.77E-09 5.74E-09 5.78E-09 5.82E-09 5.80E-09

Biased StatisticsAverage Biased -2.08E-09 -1.85E-09 -1.50E-09 -8.24E-10 -1.23E-09 -1.12E-09 -1.23E-09Std Dev Biased 3.10E-09 2.86E-09 2.47E-09 2.87E-09 2.49E-09 2.45E-09 2.54E-09Ps90%/90% (+KTL) Biased 6.44E-09 5.99E-09 5.26E-09 7.06E-09 5.60E-09 5.60E-09 5.74E-09Ps90%/90% (-KTL) Biased -1.06E-08 -9.69E-09 -8.27E-09 -8.70E-09 -8.07E-09 -7.83E-09 -8.19E-09Un-Biased StatisticsAverage Un-Biased -1.24E-09 -1.46E-09 -1.29E-09 -1.43E-09 -1.48E-09 -1.45E-09 -1.74E-09Std Dev Un-Biased 2.87E-09 2.94E-09 2.89E-09 3.10E-09 2.49E-09 2.89E-09 2.62E-09Ps90%/90% (+KTL) Un-Biased 6.63E-09 6.60E-09 6.64E-09 7.09E-09 5.36E-09 6.48E-09 5.45E-09Ps90%/90% (-KTL) Un-Biased -9.11E-09 -9.52E-09 -9.21E-09 -9.94E-09 -8.32E-09 -9.39E-09 -8.93E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 233: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

233

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=0

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.113. Plot of Positive Input Bias Current @ 3V, VCM=0V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 234: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

234

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.113. Raw data for Positive Input Bias Current @ 3V, VCM=0V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=0V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.08E-07 -3.15E-07 -3.21E-07 -3.24E-07 -3.31E-07 -3.22E-07 -3.16E-07879 -3.07E-07 -3.26E-07 -3.32E-07 -3.35E-07 -3.52E-07 -3.37E-07 -3.30E-07882 -3.33E-07 -3.41E-07 -3.50E-07 -3.54E-07 -3.60E-07 -3.52E-07 -3.38E-07883 -3.30E-07 -3.36E-07 -3.39E-07 -3.46E-07 -3.50E-07 -3.39E-07 -3.31E-07885 -3.15E-07 -3.23E-07 -3.27E-07 -3.36E-07 -3.38E-07 -3.30E-07 -3.23E-07886 -3.08E-07 -3.16E-07 -3.23E-07 -3.28E-07 -3.37E-07 -3.36E-07 -3.20E-07887 -3.24E-07 -3.32E-07 -3.39E-07 -3.49E-07 -3.58E-07 -3.54E-07 -3.35E-07891 -3.33E-07 -3.40E-07 -3.49E-07 -3.54E-07 -3.60E-07 -3.60E-07 -3.49E-07892 -3.32E-07 -3.38E-07 -3.47E-07 -3.50E-07 -3.57E-07 -3.55E-07 -3.40E-07895 -3.28E-07 -3.35E-07 -3.40E-07 -3.49E-07 -3.59E-07 -3.57E-07 -3.37E-07896 -3.50E-07 -3.50E-07 -3.51E-07 -3.48E-07 -3.49E-07 -3.50E-07 -3.49E-07

Biased StatisticsAverage Biased -3.19E-07 -3.28E-07 -3.34E-07 -3.39E-07 -3.46E-07 -3.36E-07 -3.28E-07Std Dev Biased 1.22E-08 1.03E-08 1.13E-08 1.14E-08 1.15E-08 1.11E-08 8.54E-09Ps90%/90% (+KTL) Biased -2.86E-07 -3.00E-07 -3.03E-07 -3.08E-07 -3.15E-07 -3.05E-07 -3.04E-07Ps90%/90% (-KTL) Biased -3.52E-07 -3.56E-07 -3.65E-07 -3.70E-07 -3.78E-07 -3.66E-07 -3.51E-07Un-Biased StatisticsAverage Un-Biased -3.25E-07 -3.32E-07 -3.39E-07 -3.46E-07 -3.54E-07 -3.53E-07 -3.36E-07Std Dev Un-Biased 1.01E-08 9.61E-09 1.03E-08 1.05E-08 9.77E-09 9.58E-09 1.05E-08Ps90%/90% (+KTL) Un-Biased -2.98E-07 -3.06E-07 -3.11E-07 -3.17E-07 -3.27E-07 -3.26E-07 -3.07E-07Ps90%/90% (-KTL) Un-Biased -3.53E-07 -3.59E-07 -3.68E-07 -3.75E-07 -3.81E-07 -3.79E-07 -3.65E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 235: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

235

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=0

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.114. Plot of Positive Input Bias Current @ 3V, VCM=0V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 236: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

236

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.114. Raw data for Positive Input Bias Current @ 3V, VCM=0V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=0V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.16E-07 -3.23E-07 -3.28E-07 -3.30E-07 -3.38E-07 -3.30E-07 -3.24E-07879 -3.15E-07 -3.34E-07 -3.36E-07 -3.36E-07 -3.51E-07 -3.46E-07 -3.37E-07882 -3.14E-07 -3.22E-07 -3.26E-07 -3.29E-07 -3.35E-07 -3.27E-07 -3.21E-07883 -3.22E-07 -3.28E-07 -3.30E-07 -3.33E-07 -3.36E-07 -3.28E-07 -3.22E-07885 -3.19E-07 -3.25E-07 -3.29E-07 -3.37E-07 -3.38E-07 -3.30E-07 -3.24E-07886 -3.07E-07 -3.14E-07 -3.20E-07 -3.25E-07 -3.32E-07 -3.32E-07 -3.17E-07887 -3.30E-07 -3.36E-07 -3.39E-07 -3.47E-07 -3.51E-07 -3.52E-07 -3.38E-07891 -3.15E-07 -3.22E-07 -3.28E-07 -3.33E-07 -3.46E-07 -3.41E-07 -3.26E-07892 -3.17E-07 -3.24E-07 -3.29E-07 -3.33E-07 -3.41E-07 -3.40E-07 -3.26E-07895 -3.08E-07 -3.15E-07 -3.21E-07 -3.26E-07 -3.35E-07 -3.34E-07 -3.19E-07896 -3.28E-07 -3.28E-07 -3.28E-07 -3.27E-07 -3.27E-07 -3.29E-07 -3.28E-07

Biased StatisticsAverage Biased -3.18E-07 -3.26E-07 -3.30E-07 -3.33E-07 -3.39E-07 -3.32E-07 -3.25E-07Std Dev Biased 3.24E-09 4.72E-09 3.50E-09 3.33E-09 6.40E-09 7.69E-09 6.73E-09Ps90%/90% (+KTL) Biased -3.09E-07 -3.14E-07 -3.20E-07 -3.24E-07 -3.22E-07 -3.11E-07 -3.07E-07Ps90%/90% (-KTL) Biased -3.26E-07 -3.39E-07 -3.39E-07 -3.42E-07 -3.57E-07 -3.53E-07 -3.44E-07Un-Biased StatisticsAverage Un-Biased -3.16E-07 -3.22E-07 -3.27E-07 -3.33E-07 -3.41E-07 -3.40E-07 -3.25E-07Std Dev Un-Biased 9.38E-09 8.74E-09 7.60E-09 8.67E-09 7.66E-09 7.62E-09 8.08E-09Ps90%/90% (+KTL) Un-Biased -2.90E-07 -2.98E-07 -3.06E-07 -3.09E-07 -3.20E-07 -3.19E-07 -3.03E-07Ps90%/90% (-KTL) Un-Biased -3.41E-07 -3.46E-07 -3.48E-07 -3.57E-07 -3.62E-07 -3.61E-07 -3.47E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 237: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

237

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=0

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.115. Plot of Positive Input Bias Current @ 3V, VCM=0V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 238: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

238

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.115. Raw data for Positive Input Bias Current @ 3V, VCM=0V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=0V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.13E-07 -3.19E-07 -3.25E-07 -3.28E-07 -3.36E-07 -3.26E-07 -3.20E-07879 -3.12E-07 -3.27E-07 -3.29E-07 -3.30E-07 -3.41E-07 -3.36E-07 -3.31E-07882 -3.15E-07 -3.23E-07 -3.27E-07 -3.31E-07 -3.37E-07 -3.30E-07 -3.22E-07883 -3.16E-07 -3.22E-07 -3.25E-07 -3.28E-07 -3.32E-07 -3.25E-07 -3.18E-07885 -3.21E-07 -3.28E-07 -3.32E-07 -3.40E-07 -3.40E-07 -3.33E-07 -3.26E-07886 -3.02E-07 -3.10E-07 -3.15E-07 -3.20E-07 -3.28E-07 -3.28E-07 -3.13E-07887 -3.27E-07 -3.32E-07 -3.35E-07 -3.38E-07 -3.48E-07 -3.49E-07 -3.34E-07891 -3.09E-07 -3.17E-07 -3.22E-07 -3.27E-07 -3.36E-07 -3.35E-07 -3.21E-07892 -3.11E-07 -3.18E-07 -3.23E-07 -3.28E-07 -3.35E-07 -3.34E-07 -3.20E-07895 -3.05E-07 -3.12E-07 -3.18E-07 -3.23E-07 -3.32E-07 -3.31E-07 -3.16E-07896 -3.26E-07 -3.27E-07 -3.27E-07 -3.26E-07 -3.26E-07 -3.28E-07 -3.26E-07

Biased StatisticsAverage Biased -3.15E-07 -3.24E-07 -3.28E-07 -3.32E-07 -3.37E-07 -3.30E-07 -3.23E-07Std Dev Biased 3.79E-09 3.59E-09 3.08E-09 5.07E-09 3.65E-09 4.75E-09 5.18E-09Ps90%/90% (+KTL) Biased -3.05E-07 -3.14E-07 -3.19E-07 -3.18E-07 -3.27E-07 -3.17E-07 -3.09E-07Ps90%/90% (-KTL) Biased -3.26E-07 -3.34E-07 -3.36E-07 -3.46E-07 -3.47E-07 -3.43E-07 -3.38E-07Un-Biased StatisticsAverage Un-Biased -3.11E-07 -3.18E-07 -3.23E-07 -3.27E-07 -3.36E-07 -3.35E-07 -3.21E-07Std Dev Un-Biased 9.72E-09 8.63E-09 7.69E-09 6.90E-09 7.41E-09 8.29E-09 8.05E-09Ps90%/90% (+KTL) Un-Biased -2.84E-07 -2.94E-07 -3.02E-07 -3.08E-07 -3.16E-07 -3.13E-07 -2.99E-07Ps90%/90% (-KTL) Un-Biased -3.38E-07 -3.41E-07 -3.44E-07 -3.46E-07 -3.56E-07 -3.58E-07 -3.43E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 239: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

239

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=0

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.116. Plot of Positive Input Bias Current @ 3V, VCM=0V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 240: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

240

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.116. Raw data for Positive Input Bias Current @ 3V, VCM=0V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=0V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.15E-07 -3.22E-07 -3.26E-07 -3.30E-07 -3.36E-07 -3.27E-07 -3.21E-07879 -3.14E-07 -3.28E-07 -3.33E-07 -3.35E-07 -3.53E-07 -3.39E-07 -3.31E-07882 -3.30E-07 -3.38E-07 -3.46E-07 -3.50E-07 -3.53E-07 -3.45E-07 -3.35E-07883 -3.31E-07 -3.36E-07 -3.39E-07 -3.47E-07 -3.50E-07 -3.38E-07 -3.32E-07885 -3.12E-07 -3.19E-07 -3.24E-07 -3.32E-07 -3.34E-07 -3.26E-07 -3.19E-07886 -3.15E-07 -3.23E-07 -3.29E-07 -3.34E-07 -3.46E-07 -3.50E-07 -3.26E-07887 -3.30E-07 -3.38E-07 -3.48E-07 -3.54E-07 -3.62E-07 -3.60E-07 -3.45E-07891 -3.32E-07 -3.39E-07 -3.49E-07 -3.52E-07 -3.61E-07 -3.60E-07 -3.40E-07892 -3.27E-07 -3.33E-07 -3.37E-07 -3.41E-07 -3.53E-07 -3.52E-07 -3.35E-07895 -3.28E-07 -3.35E-07 -3.41E-07 -3.50E-07 -3.58E-07 -3.59E-07 -3.38E-07896 -3.57E-07 -3.59E-07 -3.58E-07 -3.60E-07 -3.54E-07 -3.55E-07 -3.55E-07

Biased StatisticsAverage Biased -3.20E-07 -3.29E-07 -3.34E-07 -3.39E-07 -3.45E-07 -3.35E-07 -3.28E-07Std Dev Biased 9.23E-09 8.28E-09 9.00E-09 9.16E-09 9.18E-09 8.34E-09 6.93E-09Ps90%/90% (+KTL) Biased -2.95E-07 -3.06E-07 -3.09E-07 -3.14E-07 -3.20E-07 -3.12E-07 -3.09E-07Ps90%/90% (-KTL) Biased -3.46E-07 -3.51E-07 -3.58E-07 -3.64E-07 -3.70E-07 -3.58E-07 -3.47E-07Un-Biased StatisticsAverage Un-Biased -3.26E-07 -3.34E-07 -3.41E-07 -3.46E-07 -3.56E-07 -3.56E-07 -3.37E-07Std Dev Un-Biased 6.89E-09 6.43E-09 8.40E-09 8.65E-09 6.54E-09 4.87E-09 7.01E-09Ps90%/90% (+KTL) Un-Biased -3.08E-07 -3.16E-07 -3.18E-07 -3.22E-07 -3.38E-07 -3.43E-07 -3.18E-07Ps90%/90% (-KTL) Un-Biased -3.45E-07 -3.51E-07 -3.64E-07 -3.70E-07 -3.74E-07 -3.70E-07 -3.56E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 241: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

241

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=0V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.117. Plot of Negative Input Bias Current @ 3V, VCM=0V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 242: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

242

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.117. Raw data for Negative Input Bias Current @ 3V, VCM=0V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=0V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.10E-07 -3.17E-07 -3.22E-07 -3.25E-07 -3.32E-07 -3.22E-07 -3.17E-07879 -3.09E-07 -3.28E-07 -3.33E-07 -3.36E-07 -3.55E-07 -3.40E-07 -3.32E-07882 -3.30E-07 -3.37E-07 -3.48E-07 -3.49E-07 -3.56E-07 -3.48E-07 -3.35E-07883 -3.28E-07 -3.34E-07 -3.37E-07 -3.41E-07 -3.49E-07 -3.37E-07 -3.30E-07885 -3.13E-07 -3.20E-07 -3.25E-07 -3.35E-07 -3.37E-07 -3.28E-07 -3.21E-07886 -3.13E-07 -3.21E-07 -3.26E-07 -3.32E-07 -3.41E-07 -3.40E-07 -3.24E-07887 -3.27E-07 -3.35E-07 -3.41E-07 -3.51E-07 -3.61E-07 -3.59E-07 -3.38E-07891 -3.33E-07 -3.40E-07 -3.53E-07 -3.55E-07 -3.61E-07 -3.61E-07 -3.47E-07892 -3.30E-07 -3.36E-07 -3.40E-07 -3.50E-07 -3.56E-07 -3.56E-07 -3.38E-07895 -3.29E-07 -3.36E-07 -3.48E-07 -3.53E-07 -3.62E-07 -3.60E-07 -3.40E-07896 -3.53E-07 -3.52E-07 -3.52E-07 -3.53E-07 -3.51E-07 -3.53E-07 -3.52E-07

Biased StatisticsAverage Biased -3.18E-07 -3.27E-07 -3.33E-07 -3.37E-07 -3.46E-07 -3.35E-07 -3.27E-07Std Dev Biased 1.03E-08 8.76E-09 1.01E-08 8.50E-09 1.10E-08 1.01E-08 7.64E-09Ps90%/90% (+KTL) Biased -2.90E-07 -3.03E-07 -3.05E-07 -3.14E-07 -3.15E-07 -3.07E-07 -3.06E-07Ps90%/90% (-KTL) Biased -3.46E-07 -3.51E-07 -3.61E-07 -3.60E-07 -3.76E-07 -3.63E-07 -3.48E-07Un-Biased StatisticsAverage Un-Biased -3.27E-07 -3.33E-07 -3.42E-07 -3.48E-07 -3.56E-07 -3.55E-07 -3.37E-07Std Dev Un-Biased 7.66E-09 7.35E-09 9.95E-09 9.52E-09 8.98E-09 8.68E-09 8.38E-09Ps90%/90% (+KTL) Un-Biased -3.06E-07 -3.13E-07 -3.14E-07 -3.22E-07 -3.31E-07 -3.31E-07 -3.14E-07Ps90%/90% (-KTL) Un-Biased -3.47E-07 -3.54E-07 -3.69E-07 -3.74E-07 -3.81E-07 -3.79E-07 -3.60E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 243: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

243

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=0V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.118. Plot of Negative Input Bias Current @ 3V, VCM=0V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 244: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

244

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.118. Raw data for Negative Input Bias Current @ 3V, VCM=0V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=0V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.16E-07 -3.22E-07 -3.28E-07 -3.33E-07 -3.47E-07 -3.29E-07 -3.24E-07879 -3.15E-07 -3.27E-07 -3.29E-07 -3.30E-07 -3.47E-07 -3.37E-07 -3.32E-07882 -3.12E-07 -3.19E-07 -3.23E-07 -3.26E-07 -3.32E-07 -3.24E-07 -3.17E-07883 -3.22E-07 -3.27E-07 -3.30E-07 -3.33E-07 -3.37E-07 -3.35E-07 -3.22E-07885 -3.20E-07 -3.27E-07 -3.32E-07 -3.40E-07 -3.39E-07 -3.32E-07 -3.25E-07886 -3.07E-07 -3.14E-07 -3.20E-07 -3.25E-07 -3.34E-07 -3.34E-07 -3.17E-07887 -3.24E-07 -3.29E-07 -3.33E-07 -3.36E-07 -3.41E-07 -3.46E-07 -3.31E-07891 -3.16E-07 -3.23E-07 -3.29E-07 -3.34E-07 -3.48E-07 -3.47E-07 -3.27E-07892 -3.19E-07 -3.26E-07 -3.31E-07 -3.36E-07 -3.47E-07 -3.48E-07 -3.29E-07895 -3.11E-07 -3.18E-07 -3.23E-07 -3.28E-07 -3.37E-07 -3.37E-07 -3.21E-07896 -3.30E-07 -3.31E-07 -3.31E-07 -3.30E-07 -3.30E-07 -3.32E-07 -3.30E-07

Biased StatisticsAverage Biased -3.17E-07 -3.24E-07 -3.28E-07 -3.32E-07 -3.41E-07 -3.31E-07 -3.24E-07Std Dev Biased 4.34E-09 3.80E-09 3.49E-09 5.18E-09 6.65E-09 5.29E-09 5.28E-09Ps90%/90% (+KTL) Biased -3.05E-07 -3.14E-07 -3.19E-07 -3.18E-07 -3.22E-07 -3.17E-07 -3.09E-07Ps90%/90% (-KTL) Biased -3.29E-07 -3.35E-07 -3.38E-07 -3.47E-07 -3.59E-07 -3.46E-07 -3.38E-07Un-Biased StatisticsAverage Un-Biased -3.15E-07 -3.22E-07 -3.27E-07 -3.32E-07 -3.42E-07 -3.42E-07 -3.25E-07Std Dev Un-Biased 6.68E-09 6.15E-09 5.33E-09 4.82E-09 6.15E-09 6.56E-09 5.60E-09Ps90%/90% (+KTL) Un-Biased -2.97E-07 -3.05E-07 -3.13E-07 -3.19E-07 -3.25E-07 -3.24E-07 -3.10E-07Ps90%/90% (-KTL) Un-Biased -3.34E-07 -3.39E-07 -3.42E-07 -3.45E-07 -3.58E-07 -3.60E-07 -3.40E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 245: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

245

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=0V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.119. Plot of Negative Input Bias Current @ 3V, VCM=0V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 246: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

246

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.119. Raw data for Negative Input Bias Current @ 3V, VCM=0V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=0V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.20E-07 -3.27E-07 -3.33E-07 -3.36E-07 -3.48E-07 -3.34E-07 -3.28E-07879 -3.19E-07 -3.23E-07 -3.25E-07 -3.26E-07 -3.38E-07 -3.34E-07 -3.28E-07882 -3.14E-07 -3.22E-07 -3.26E-07 -3.29E-07 -3.35E-07 -3.27E-07 -3.20E-07883 -3.20E-07 -3.26E-07 -3.29E-07 -3.32E-07 -3.35E-07 -3.28E-07 -3.21E-07885 -3.26E-07 -3.33E-07 -3.37E-07 -3.51E-07 -3.52E-07 -3.38E-07 -3.31E-07886 -3.04E-07 -3.10E-07 -3.16E-07 -3.21E-07 -3.30E-07 -3.29E-07 -3.14E-07887 -3.25E-07 -3.30E-07 -3.33E-07 -3.36E-07 -3.48E-07 -3.48E-07 -3.32E-07891 -3.13E-07 -3.20E-07 -3.26E-07 -3.31E-07 -3.39E-07 -3.38E-07 -3.24E-07892 -3.12E-07 -3.19E-07 -3.24E-07 -3.29E-07 -3.36E-07 -3.35E-07 -3.21E-07895 -3.07E-07 -3.14E-07 -3.19E-07 -3.25E-07 -3.34E-07 -3.33E-07 -3.18E-07896 -3.29E-07 -3.30E-07 -3.30E-07 -3.29E-07 -3.29E-07 -3.31E-07 -3.30E-07

Biased StatisticsAverage Biased -3.20E-07 -3.26E-07 -3.30E-07 -3.35E-07 -3.42E-07 -3.32E-07 -3.26E-07Std Dev Biased 4.31E-09 4.18E-09 4.82E-09 9.56E-09 7.79E-09 4.43E-09 4.95E-09Ps90%/90% (+KTL) Biased -3.08E-07 -3.15E-07 -3.17E-07 -3.09E-07 -3.20E-07 -3.20E-07 -3.12E-07Ps90%/90% (-KTL) Biased -3.32E-07 -3.38E-07 -3.43E-07 -3.61E-07 -3.63E-07 -3.44E-07 -3.39E-07Un-Biased StatisticsAverage Un-Biased -3.12E-07 -3.19E-07 -3.24E-07 -3.28E-07 -3.37E-07 -3.37E-07 -3.22E-07Std Dev Un-Biased 8.15E-09 7.55E-09 6.53E-09 5.94E-09 6.74E-09 7.09E-09 6.84E-09Ps90%/90% (+KTL) Un-Biased -2.90E-07 -2.98E-07 -3.06E-07 -3.12E-07 -3.19E-07 -3.17E-07 -3.03E-07Ps90%/90% (-KTL) Un-Biased -3.34E-07 -3.39E-07 -3.42E-07 -3.45E-07 -3.56E-07 -3.56E-07 -3.41E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 247: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

247

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=0V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.120. Plot of Negative Input Bias Current @ 3V, VCM=0V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 248: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

248

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.120. Raw data for Negative Input Bias Current @ 3V, VCM=0V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=0V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.10E-07 -3.17E-07 -3.23E-07 -3.26E-07 -3.32E-07 -3.23E-07 -3.17E-07879 -3.09E-07 -3.25E-07 -3.31E-07 -3.34E-07 -3.53E-07 -3.37E-07 -3.30E-07882 -3.32E-07 -3.40E-07 -3.49E-07 -3.53E-07 -3.57E-07 -3.48E-07 -3.36E-07883 -3.28E-07 -3.33E-07 -3.36E-07 -3.41E-07 -3.48E-07 -3.36E-07 -3.29E-07885 -3.13E-07 -3.20E-07 -3.26E-07 -3.35E-07 -3.36E-07 -3.28E-07 -3.21E-07886 -3.16E-07 -3.23E-07 -3.29E-07 -3.34E-07 -3.47E-07 -3.47E-07 -3.26E-07887 -3.28E-07 -3.35E-07 -3.48E-07 -3.53E-07 -3.60E-07 -3.58E-07 -3.38E-07891 -3.29E-07 -3.36E-07 -3.41E-07 -3.52E-07 -3.58E-07 -3.57E-07 -3.37E-07892 -3.30E-07 -3.36E-07 -3.40E-07 -3.50E-07 -3.57E-07 -3.54E-07 -3.37E-07895 -3.25E-07 -3.31E-07 -3.37E-07 -3.47E-07 -3.55E-07 -3.54E-07 -3.34E-07896 -3.60E-07 -3.62E-07 -3.64E-07 -3.59E-07 -3.65E-07 -3.61E-07 -3.64E-07

Biased StatisticsAverage Biased -3.18E-07 -3.27E-07 -3.33E-07 -3.37E-07 -3.45E-07 -3.34E-07 -3.27E-07Std Dev Biased 1.05E-08 9.32E-09 1.03E-08 1.01E-08 1.08E-08 9.76E-09 7.62E-09Ps90%/90% (+KTL) Biased -2.90E-07 -3.02E-07 -3.05E-07 -3.10E-07 -3.16E-07 -3.08E-07 -3.06E-07Ps90%/90% (-KTL) Biased -3.47E-07 -3.53E-07 -3.61E-07 -3.65E-07 -3.75E-07 -3.61E-07 -3.47E-07Un-Biased StatisticsAverage Un-Biased -3.26E-07 -3.32E-07 -3.39E-07 -3.47E-07 -3.55E-07 -3.54E-07 -3.35E-07Std Dev Un-Biased 5.81E-09 5.50E-09 6.68E-09 7.67E-09 4.97E-09 4.44E-09 4.99E-09Ps90%/90% (+KTL) Un-Biased -3.10E-07 -3.17E-07 -3.21E-07 -3.26E-07 -3.42E-07 -3.42E-07 -3.21E-07Ps90%/90% (-KTL) Un-Biased -3.41E-07 -3.47E-07 -3.57E-07 -3.68E-07 -3.69E-07 -3.66E-07 -3.48E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 249: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

249

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=3

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.121. Plot of Input Offset Voltage @ 3V, VCM=3V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 250: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

250

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.121. Raw data for Input Offset Voltage @ 3V, VCM=3V #1 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 5.31E-05 3.47E-05 4.36E-05 5.02E-05 6.06E-05 4.93E-05 4.22E-05879 5.34E-05 2.43E-04 2.56E-04 2.48E-04 2.51E-04 2.41E-04 2.52E-04882 3.48E-04 3.43E-04 3.47E-04 3.50E-04 3.63E-04 3.51E-04 3.58E-04883 3.43E-04 3.26E-04 3.33E-04 3.48E-04 3.51E-04 3.36E-04 3.38E-04885 8.94E-05 7.19E-05 7.96E-05 8.18E-05 8.07E-05 7.35E-05 6.22E-05886 5.48E-05 3.94E-05 3.65E-05 3.22E-05 2.63E-05 2.48E-05 1.95E-05887 4.04E-04 3.93E-04 3.93E-04 3.91E-04 3.85E-04 3.81E-04 3.79E-04891 3.17E-04 3.00E-04 2.99E-04 2.94E-04 2.92E-04 2.86E-04 2.76E-04892 -1.16E-04 -1.27E-04 -1.30E-04 -1.35E-04 -1.37E-04 -1.38E-04 -1.33E-04895 1.22E-04 1.06E-04 1.02E-04 9.81E-05 8.52E-05 8.27E-05 1.05E-04896 -6.92E-05 -7.06E-05 -7.01E-05 -7.01E-05 -6.99E-05 -7.09E-05 -7.00E-05

Biased StatisticsAverage Biased 1.77E-04 2.04E-04 2.12E-04 2.16E-04 2.21E-04 2.10E-04 2.10E-04Std Dev Biased 1.54E-04 1.43E-04 1.42E-04 1.43E-04 1.44E-04 1.42E-04 1.50E-04Ps90%/90% (+KTL) Biased 6.00E-04 5.96E-04 6.01E-04 6.08E-04 6.17E-04 6.01E-04 6.22E-04Ps90%/90% (-KTL) Biased -2.45E-04 -1.89E-04 -1.77E-04 -1.77E-04 -1.75E-04 -1.80E-04 -2.01E-04Un-Biased StatisticsAverage Un-Biased 1.56E-04 1.42E-04 1.40E-04 1.36E-04 1.30E-04 1.28E-04 1.29E-04Std Dev Un-Biased 2.08E-04 2.08E-04 2.09E-04 2.09E-04 2.09E-04 2.08E-04 2.03E-04Ps90%/90% (+KTL) Un-Biased 7.26E-04 7.11E-04 7.12E-04 7.10E-04 7.04E-04 6.97E-04 6.87E-04Ps90%/90% (-KTL) Un-Biased -4.14E-04 -4.27E-04 -4.32E-04 -4.38E-04 -4.44E-04 -4.42E-04 -4.28E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 251: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

251

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=3

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.122. Plot of Input Offset Voltage @ 3V, VCM=3V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 252: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

252

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.122. Raw data for Input Offset Voltage @ 3V, VCM=3V #2 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 2.63E-04 2.45E-04 2.48E-04 2.78E-04 3.15E-04 2.81E-04 2.65E-04879 2.65E-04 1.31E-04 1.52E-04 1.44E-04 1.45E-04 1.42E-04 1.53E-04882 2.85E-04 2.76E-04 2.76E-04 2.80E-04 2.97E-04 2.84E-04 2.81E-04883 7.76E-05 6.38E-05 7.65E-05 9.67E-05 9.62E-05 1.07E-04 8.64E-05885 1.46E-04 1.45E-04 1.74E-04 1.65E-04 1.66E-04 1.48E-04 1.58E-04886 2.04E-04 1.87E-04 1.84E-04 1.83E-04 1.79E-04 1.78E-04 1.64E-04887 1.83E-04 1.90E-04 1.90E-04 1.88E-04 1.90E-04 1.83E-04 1.68E-04891 3.09E-04 3.09E-04 3.11E-04 3.10E-04 3.10E-04 3.05E-04 3.00E-04892 6.65E-05 5.96E-05 5.77E-05 5.55E-05 5.46E-05 4.42E-05 4.12E-05895 1.14E-04 1.02E-04 1.02E-04 1.00E-04 9.93E-05 9.22E-05 9.04E-05896 6.14E-05 6.20E-05 6.08E-05 6.29E-05 6.14E-05 6.03E-05 6.18E-05

Biased StatisticsAverage Biased 2.07E-04 1.72E-04 1.85E-04 1.93E-04 2.04E-04 1.93E-04 1.89E-04Std Dev Biased 9.10E-05 8.67E-05 7.94E-05 8.26E-05 9.68E-05 8.40E-05 8.20E-05Ps90%/90% (+KTL) Biased 4.57E-04 4.10E-04 4.03E-04 4.19E-04 4.69E-04 4.23E-04 4.14E-04Ps90%/90% (-KTL) Biased -4.23E-05 -6.58E-05 -3.26E-05 -3.35E-05 -6.17E-05 -3.76E-05 -3.63E-05Un-Biased StatisticsAverage Un-Biased 1.75E-04 1.70E-04 1.69E-04 1.68E-04 1.67E-04 1.60E-04 1.53E-04Std Dev Un-Biased 9.27E-05 9.60E-05 9.70E-05 9.77E-05 9.80E-05 9.97E-05 9.80E-05Ps90%/90% (+KTL) Un-Biased 4.29E-04 4.33E-04 4.35E-04 4.35E-04 4.35E-04 4.34E-04 4.21E-04Ps90%/90% (-KTL) Un-Biased -7.89E-05 -9.35E-05 -9.71E-05 -1.00E-04 -1.02E-04 -1.13E-04 -1.16E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 253: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

253

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=3

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.123. Plot of Input Offset Voltage @ 3V, VCM=3V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 254: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

254

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.123. Raw data for Input Offset Voltage @ 3V, VCM=3V #3 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -1.03E-04 -1.23E-04 -1.15E-04 -1.07E-04 -1.04E-04 -1.09E-04 -1.10E-04879 -1.03E-04 4.06E-04 4.27E-04 4.18E-04 4.23E-04 4.14E-04 4.35E-04882 1.24E-04 1.03E-04 1.05E-04 1.08E-04 1.20E-04 1.06E-04 9.78E-05883 3.39E-04 3.15E-04 3.17E-04 3.38E-04 3.33E-04 3.26E-04 3.17E-04885 8.46E-05 5.97E-05 6.20E-05 7.40E-05 5.52E-05 5.02E-05 6.41E-05886 -2.82E-05 -4.09E-05 -4.30E-05 -4.65E-05 -5.03E-05 -5.08E-05 -5.31E-05887 -1.43E-04 -1.37E-04 -1.40E-04 -1.50E-04 -1.56E-04 -1.53E-04 -1.59E-04891 3.45E-04 3.35E-04 3.37E-04 3.35E-04 3.33E-04 3.28E-04 3.25E-04892 2.70E-04 2.58E-04 2.57E-04 2.60E-04 2.62E-04 2.57E-04 2.51E-04895 1.07E-04 9.06E-05 8.83E-05 8.71E-05 8.25E-05 8.07E-05 8.17E-05896 1.70E-04 1.67E-04 1.69E-04 1.70E-04 1.70E-04 1.66E-04 1.69E-04

Biased StatisticsAverage Biased 6.85E-05 1.52E-04 1.59E-04 1.66E-04 1.66E-04 1.57E-04 1.61E-04Std Dev Biased 1.84E-04 2.11E-04 2.14E-04 2.12E-04 2.13E-04 2.12E-04 2.16E-04Ps90%/90% (+KTL) Biased 5.72E-04 7.30E-04 7.47E-04 7.47E-04 7.50E-04 7.38E-04 7.53E-04Ps90%/90% (-KTL) Biased -4.35E-04 -4.26E-04 -4.29E-04 -4.15E-04 -4.19E-04 -4.24E-04 -4.31E-04Un-Biased StatisticsAverage Un-Biased 1.10E-04 1.01E-04 9.99E-05 9.69E-05 9.41E-05 9.22E-05 8.92E-05Std Dev Un-Biased 2.02E-04 1.98E-04 1.99E-04 2.03E-04 2.05E-04 2.02E-04 2.02E-04Ps90%/90% (+KTL) Un-Biased 6.65E-04 6.44E-04 6.47E-04 6.54E-04 6.57E-04 6.46E-04 6.44E-04Ps90%/90% (-KTL) Un-Biased -4.45E-04 -4.41E-04 -4.47E-04 -4.60E-04 -4.69E-04 -4.62E-04 -4.65E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 255: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

255

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

3V,

VC

M=3

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.124. Plot of Input Offset Voltage @ 3V, VCM=3V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 256: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

256

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.124. Raw data for Input Offset Voltage @ 3V, VCM=3V #4 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 3V, VCM=3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.35E-04 1.16E-04 1.27E-04 1.33E-04 1.50E-04 1.39E-04 1.29E-04879 1.36E-04 1.76E-04 1.93E-04 1.84E-04 1.88E-04 1.85E-04 1.77E-04882 2.25E-05 1.04E-05 1.88E-05 2.44E-05 3.30E-05 2.60E-05 3.60E-05883 2.87E-05 1.56E-05 2.38E-05 5.00E-05 3.57E-05 3.08E-05 3.14E-05885 1.13E-04 8.95E-05 9.45E-05 1.05E-04 9.43E-05 8.88E-05 8.04E-05886 1.80E-04 1.67E-04 1.62E-04 1.62E-04 1.63E-04 1.54E-04 1.57E-04887 -1.51E-05 -3.04E-05 -3.00E-05 -2.97E-05 -3.67E-05 -3.93E-05 -3.27E-05891 1.49E-04 1.37E-04 1.37E-04 1.40E-04 1.43E-04 1.37E-04 1.25E-04892 9.45E-05 9.99E-05 9.96E-05 1.09E-04 1.06E-04 1.05E-04 9.97E-05895 3.95E-04 3.83E-04 3.80E-04 3.77E-04 3.68E-04 3.60E-04 3.60E-04896 7.41E-05 7.24E-05 7.12E-05 7.05E-05 6.97E-05 6.95E-05 7.28E-05

Biased StatisticsAverage Biased 8.69E-05 8.15E-05 9.14E-05 9.93E-05 1.00E-04 9.39E-05 9.07E-05Std Dev Biased 5.68E-05 7.00E-05 7.32E-05 6.39E-05 6.89E-05 6.88E-05 6.23E-05Ps90%/90% (+KTL) Biased 2.43E-04 2.73E-04 2.92E-04 2.75E-04 2.89E-04 2.82E-04 2.61E-04Ps90%/90% (-KTL) Biased -6.87E-05 -1.10E-04 -1.09E-04 -7.60E-05 -8.87E-05 -9.46E-05 -8.00E-05Un-Biased StatisticsAverage Un-Biased 1.61E-04 1.51E-04 1.50E-04 1.52E-04 1.49E-04 1.43E-04 1.42E-04Std Dev Un-Biased 1.51E-04 1.50E-04 1.49E-04 1.46E-04 1.45E-04 1.43E-04 1.42E-04Ps90%/90% (+KTL) Un-Biased 5.74E-04 5.63E-04 5.57E-04 5.53E-04 5.47E-04 5.36E-04 5.31E-04Ps90%/90% (-KTL) Un-Biased -2.52E-04 -2.60E-04 -2.58E-04 -2.50E-04 -2.50E-04 -2.49E-04 -2.47E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 257: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

257

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=3

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.125. Plot of Input Offset Current @ 3V, VCM=3V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 258: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

258

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.125. Raw data for Input Offset Current @ 3V, VCM=3V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=3V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.12E-09 4.24E-10 3.21E-10 1.57E-09 1.16E-09 3.13E-10 1.61E-08879 1.11E-09 8.84E-09 8.86E-09 9.07E-09 1.62E-08 1.34E-08 2.78E-08882 4.04E-09 5.74E-09 4.64E-09 5.56E-09 6.76E-09 4.39E-09 1.87E-08883 -6.43E-10 -1.04E-09 -8.40E-10 -2.37E-10 1.35E-09 -2.73E-10 1.52E-08885 6.23E-09 4.77E-09 5.46E-09 7.38E-09 5.46E-09 3.28E-09 2.35E-08886 2.02E-09 1.46E-09 1.28E-09 -9.20E-11 -2.38E-10 4.35E-10 1.40E-09887 1.62E-08 1.61E-08 1.73E-08 1.63E-08 1.60E-08 1.63E-08 1.47E-08891 2.75E-09 2.62E-09 3.18E-09 3.94E-09 5.17E-09 4.37E-09 2.72E-09892 2.04E-09 1.25E-09 7.73E-10 1.52E-09 2.74E-09 2.24E-09 8.88E-10895 9.14E-09 9.44E-09 8.50E-09 7.91E-09 7.91E-09 8.63E-09 7.61E-09896 1.88E-10 1.91E-10 1.54E-10 1.47E-10 1.55E-10 1.31E-10 2.29E-10

Biased StatisticsAverage Biased 2.37E-09 3.75E-09 3.69E-09 4.67E-09 6.18E-09 4.22E-09 2.03E-08Std Dev Biased 2.73E-09 4.03E-09 3.96E-09 3.91E-09 6.11E-09 5.48E-09 5.30E-09Ps90%/90% (+KTL) Biased 9.87E-09 1.48E-08 1.45E-08 1.54E-08 2.29E-08 1.92E-08 3.48E-08Ps90%/90% (-KTL) Biased -5.13E-09 -7.30E-09 -7.16E-09 -6.06E-09 -1.06E-08 -1.08E-08 5.76E-09Un-Biased StatisticsAverage Un-Biased 6.43E-09 6.18E-09 6.20E-09 5.92E-09 6.31E-09 6.39E-09 5.47E-09Std Dev Un-Biased 6.22E-09 6.49E-09 6.89E-09 6.54E-09 6.19E-09 6.33E-09 5.81E-09Ps90%/90% (+KTL) Un-Biased 2.35E-08 2.40E-08 2.51E-08 2.39E-08 2.33E-08 2.37E-08 2.14E-08Ps90%/90% (-KTL) Un-Biased -1.06E-08 -1.16E-08 -1.27E-08 -1.20E-08 -1.07E-08 -1.10E-08 -1.05E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 259: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

259

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=3

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.126. Plot of Input Offset Current @ 3V, VCM=3V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 260: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

260

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.126. Raw data for Input Offset Current @ 3V, VCM=3V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=3V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.85E-09 -4.10E-09 -3.48E-09 -8.98E-10 1.88E-09 4.05E-09 2.35E-08879 -2.59E-09 4.05E-09 6.30E-09 6.89E-09 1.46E-08 1.17E-08 2.62E-08882 6.91E-10 2.90E-09 3.57E-09 2.44E-09 1.08E-09 2.26E-09 1.84E-08883 1.92E-09 2.76E-09 2.70E-09 5.76E-09 6.10E-09 -2.81E-10 1.96E-08885 2.14E-09 3.77E-09 7.67E-09 1.03E-08 7.59E-09 4.60E-09 2.22E-08886 -1.31E-08 -1.23E-08 -1.19E-08 -1.20E-08 -1.14E-08 -1.15E-08 -1.29E-08887 1.63E-08 1.72E-08 1.70E-08 1.58E-08 1.49E-08 1.59E-08 1.56E-08891 -1.92E-09 -1.06E-09 -4.14E-10 6.69E-10 1.07E-09 2.11E-10 -1.03E-09892 -4.84E-09 -3.97E-09 -3.69E-09 -2.64E-09 -2.44E-09 -3.88E-09 -5.11E-09895 5.77E-09 5.67E-09 5.49E-09 5.39E-09 4.75E-09 3.59E-09 3.97E-09896 -7.98E-09 -9.01E-09 -9.08E-09 -9.04E-09 -8.69E-09 -9.35E-09 -8.89E-09

Biased StatisticsAverage Biased -1.38E-10 1.88E-09 3.35E-09 4.90E-09 6.24E-09 4.46E-09 2.20E-08Std Dev Biased 2.42E-09 3.38E-09 4.31E-09 4.28E-09 5.40E-09 4.47E-09 3.09E-09Ps90%/90% (+KTL) Biased 6.50E-09 1.12E-08 1.52E-08 1.66E-08 2.11E-08 1.67E-08 3.04E-08Ps90%/90% (-KTL) Biased -6.78E-09 -7.41E-09 -8.48E-09 -6.85E-09 -8.56E-09 -7.78E-09 1.35E-08Un-Biased StatisticsAverage Un-Biased 4.37E-10 1.11E-09 1.31E-09 1.45E-09 1.37E-09 8.63E-10 9.06E-11Std Dev Un-Biased 1.12E-08 1.11E-08 1.08E-08 1.02E-08 9.65E-09 1.01E-08 1.06E-08Ps90%/90% (+KTL) Un-Biased 3.10E-08 3.14E-08 3.09E-08 2.95E-08 2.78E-08 2.86E-08 2.93E-08Ps90%/90% (-KTL) Un-Biased -3.02E-08 -2.92E-08 -2.83E-08 -2.66E-08 -2.51E-08 -2.69E-08 -2.91E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 261: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

261

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=3

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.127. Plot of Input Offset Current @ 3V, VCM=3V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 262: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

262

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.127. Raw data for Input Offset Current @ 3V, VCM=3V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=3V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -6.83E-09 -6.83E-09 -7.00E-09 -7.28E-09 -6.41E-09 -6.79E-09 7.74E-09879 -6.80E-09 -7.59E-09 -6.26E-09 -4.20E-09 3.77E-09 1.54E-09 1.68E-08882 -9.47E-09 -9.08E-09 -8.52E-09 -8.98E-09 -1.07E-08 -1.20E-08 4.53E-09883 5.57E-09 6.65E-09 6.01E-09 1.02E-08 9.82E-09 7.95E-09 2.25E-08885 -5.82E-09 -5.99E-09 -7.00E-09 -6.45E-10 -2.94E-09 -3.71E-09 1.15E-08886 -2.55E-09 -3.59E-09 -2.47E-09 -2.69E-09 -2.45E-09 -3.19E-09 -2.45E-09887 -6.38E-09 -6.50E-09 -5.50E-09 -3.96E-09 -3.81E-09 -4.75E-09 -6.78E-09891 1.42E-08 1.44E-08 1.53E-08 1.63E-08 1.59E-08 1.52E-08 1.39E-08892 -6.89E-09 -6.47E-09 -7.99E-09 -5.25E-09 -2.61E-09 -4.96E-09 -7.08E-09895 -1.41E-08 -1.55E-08 -1.54E-08 -1.47E-08 -1.53E-08 -1.45E-08 -1.47E-08896 -5.92E-09 -5.83E-09 -5.87E-09 -5.79E-09 -5.81E-09 -5.89E-09 -5.87E-09

Biased StatisticsAverage Biased -4.67E-09 -4.57E-09 -4.55E-09 -2.18E-09 -1.29E-09 -2.59E-09 1.26E-08Std Dev Biased 5.88E-09 6.38E-09 5.96E-09 7.62E-09 8.16E-09 7.66E-09 7.18E-09Ps90%/90% (+KTL) Biased 1.15E-08 1.29E-08 1.18E-08 1.87E-08 2.11E-08 1.84E-08 3.23E-08Ps90%/90% (-KTL) Biased -2.08E-08 -2.21E-08 -2.09E-08 -2.31E-08 -2.37E-08 -2.36E-08 -7.07E-09Un-Biased StatisticsAverage Un-Biased -3.15E-09 -3.52E-09 -3.22E-09 -2.06E-09 -1.66E-09 -2.44E-09 -3.41E-09Std Dev Un-Biased 1.06E-08 1.10E-08 1.14E-08 1.13E-08 1.12E-08 1.08E-08 1.06E-08Ps90%/90% (+KTL) Un-Biased 2.58E-08 2.66E-08 2.80E-08 2.89E-08 2.90E-08 2.73E-08 2.57E-08Ps90%/90% (-KTL) Un-Biased -3.21E-08 -3.36E-08 -3.45E-08 -3.30E-08 -3.23E-08 -3.22E-08 -3.26E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 263: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

263

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

3V,

VC

M=3

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.128. Plot of Input Offset Current @ 3V, VCM=3V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 264: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

264

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.128. Raw data for Input Offset Current @ 3V, VCM=3V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 3V, VCM=3V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -8.75E-09 -7.11E-09 -7.11E-09 -5.60E-09 -4.67E-09 -6.48E-09 7.78E-09879 -9.03E-09 -1.19E-08 -1.02E-08 -1.07E-08 -5.34E-09 -5.15E-09 9.23E-09882 1.15E-08 1.24E-08 1.28E-08 1.32E-08 1.23E-08 1.29E-08 2.55E-08883 2.39E-10 -1.20E-09 -1.70E-09 -4.19E-10 -1.35E-09 -3.30E-09 1.63E-08885 1.88E-09 2.44E-09 3.28E-09 7.77E-09 4.73E-09 4.71E-09 1.97E-08886 -5.08E-09 -4.91E-09 -4.68E-09 -4.09E-09 -2.71E-09 -4.53E-09 -5.72E-09887 1.55E-08 1.47E-08 1.39E-08 1.41E-08 1.25E-08 1.30E-08 1.47E-08891 1.46E-08 1.40E-08 1.35E-08 1.51E-08 1.54E-08 1.55E-08 1.49E-08892 -1.23E-08 -1.13E-08 -9.49E-09 -9.31E-09 -6.96E-09 -6.50E-09 -1.06E-08895 2.25E-09 2.44E-09 2.31E-09 2.93E-09 2.33E-09 1.41E-09 6.82E-10896 -1.41E-09 -1.47E-09 -9.60E-10 -1.35E-09 -1.44E-09 -1.54E-09 -1.60E-09

Biased StatisticsAverage Biased -8.42E-10 -1.06E-09 -5.95E-10 8.47E-10 1.14E-09 5.44E-10 1.57E-08Std Dev Biased 8.51E-09 9.33E-09 9.10E-09 9.70E-09 7.41E-09 8.18E-09 7.37E-09Ps90%/90% (+KTL) Biased 2.25E-08 2.45E-08 2.43E-08 2.74E-08 2.15E-08 2.30E-08 3.59E-08Ps90%/90% (-KTL) Biased -2.42E-08 -2.66E-08 -2.55E-08 -2.57E-08 -1.92E-08 -2.19E-08 -4.50E-09Un-Biased StatisticsAverage Un-Biased 2.99E-09 2.99E-09 3.11E-09 3.76E-09 4.11E-09 3.78E-09 2.79E-09Std Dev Un-Biased 1.22E-08 1.15E-08 1.05E-08 1.08E-08 9.62E-09 1.00E-08 1.17E-08Ps90%/90% (+KTL) Un-Biased 3.64E-08 3.44E-08 3.20E-08 3.35E-08 3.05E-08 3.13E-08 3.48E-08Ps90%/90% (-KTL) Un-Biased -3.04E-08 -2.84E-08 -2.58E-08 -2.60E-08 -2.23E-08 -2.37E-08 -2.92E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 265: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

265

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=3

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.129. Plot of Positive Input Bias Current @ 3V, VCM=3V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 266: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

266

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.129. Raw data for Positive Input Bias Current @ 3V, VCM=3V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=3V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.71E-07 4.03E-07 4.37E-07 4.62E-07 5.03E-07 4.62E-07 4.41E-07879 3.72E-07 4.43E-07 4.71E-07 4.96E-07 5.50E-07 5.10E-07 4.88E-07882 4.14E-07 4.51E-07 4.79E-07 5.06E-07 5.48E-07 5.08E-07 4.81E-07883 4.48E-07 4.82E-07 5.12E-07 5.35E-07 5.80E-07 5.37E-07 5.12E-07885 3.99E-07 4.30E-07 4.71E-07 5.05E-07 5.44E-07 5.00E-07 4.77E-07886 3.97E-07 4.27E-07 4.56E-07 4.82E-07 5.24E-07 5.10E-07 4.55E-07887 4.32E-07 4.59E-07 4.93E-07 5.17E-07 5.60E-07 5.44E-07 4.85E-07891 4.29E-07 4.59E-07 4.86E-07 5.13E-07 5.56E-07 5.40E-07 4.82E-07892 4.64E-07 4.94E-07 5.24E-07 5.55E-07 6.02E-07 5.84E-07 5.22E-07895 4.44E-07 4.73E-07 5.04E-07 5.33E-07 5.77E-07 5.64E-07 4.98E-07896 4.27E-07 4.28E-07 4.27E-07 4.28E-07 4.27E-07 4.30E-07 4.28E-07

Biased StatisticsAverage Biased 4.01E-07 4.42E-07 4.74E-07 5.01E-07 5.45E-07 5.03E-07 4.80E-07Std Dev Biased 3.24E-08 2.88E-08 2.70E-08 2.63E-08 2.75E-08 2.71E-08 2.55E-08Ps90%/90% (+KTL) Biased 4.90E-07 5.21E-07 5.48E-07 5.73E-07 6.21E-07 5.78E-07 5.50E-07Ps90%/90% (-KTL) Biased 3.12E-07 3.63E-07 4.00E-07 4.29E-07 4.70E-07 4.29E-07 4.10E-07Un-Biased StatisticsAverage Un-Biased 4.33E-07 4.62E-07 4.93E-07 5.20E-07 5.64E-07 5.48E-07 4.88E-07Std Dev Un-Biased 2.45E-08 2.45E-08 2.49E-08 2.68E-08 2.85E-08 2.77E-08 2.45E-08Ps90%/90% (+KTL) Un-Biased 5.00E-07 5.30E-07 5.61E-07 5.93E-07 6.42E-07 6.24E-07 5.56E-07Ps90%/90% (-KTL) Un-Biased 3.66E-07 3.95E-07 4.24E-07 4.46E-07 4.86E-07 4.72E-07 4.21E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 267: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

267

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=3

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.130. Plot of Positive Input Bias Current @ 3V, VCM=3V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 268: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

268

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.130. Raw data for Positive Input Bias Current @ 3V, VCM=3V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=3V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.97E-07 4.31E-07 4.65E-07 4.92E-07 5.35E-07 4.97E-07 4.80E-07879 3.96E-07 4.76E-07 5.00E-07 5.28E-07 5.89E-07 5.50E-07 5.31E-07882 3.86E-07 4.17E-07 4.44E-07 4.69E-07 5.08E-07 4.73E-07 4.53E-07883 4.61E-07 4.96E-07 5.25E-07 5.50E-07 5.97E-07 5.51E-07 5.27E-07885 4.38E-07 4.72E-07 5.05E-07 5.42E-07 5.75E-07 5.34E-07 5.08E-07886 3.86E-07 4.13E-07 4.42E-07 4.65E-07 5.06E-07 4.93E-07 4.40E-07887 4.65E-07 4.93E-07 5.21E-07 5.46E-07 5.90E-07 5.77E-07 5.20E-07891 4.17E-07 4.50E-07 4.78E-07 5.05E-07 5.45E-07 5.31E-07 4.76E-07892 4.39E-07 4.73E-07 5.03E-07 5.31E-07 5.74E-07 5.58E-07 4.97E-07895 3.96E-07 4.26E-07 4.56E-07 4.83E-07 5.28E-07 5.12E-07 4.53E-07896 4.14E-07 4.15E-07 4.12E-07 4.14E-07 4.13E-07 4.16E-07 4.14E-07

Biased StatisticsAverage Biased 4.16E-07 4.58E-07 4.88E-07 5.16E-07 5.61E-07 5.21E-07 5.00E-07Std Dev Biased 3.23E-08 3.31E-08 3.29E-08 3.45E-08 3.79E-08 3.46E-08 3.31E-08Ps90%/90% (+KTL) Biased 5.04E-07 5.49E-07 5.78E-07 6.11E-07 6.65E-07 6.16E-07 5.91E-07Ps90%/90% (-KTL) Biased 3.27E-07 3.68E-07 3.98E-07 4.22E-07 4.57E-07 4.26E-07 4.09E-07Un-Biased StatisticsAverage Un-Biased 4.21E-07 4.51E-07 4.80E-07 5.06E-07 5.49E-07 5.34E-07 4.77E-07Std Dev Un-Biased 3.23E-08 3.29E-08 3.24E-08 3.34E-08 3.40E-08 3.39E-08 3.25E-08Ps90%/90% (+KTL) Un-Biased 5.09E-07 5.41E-07 5.69E-07 5.98E-07 6.42E-07 6.27E-07 5.66E-07Ps90%/90% (-KTL) Un-Biased 3.32E-07 3.61E-07 3.91E-07 4.14E-07 4.55E-07 4.41E-07 3.88E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 269: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

269

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=3

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.131. Plot of Positive Input Bias Current @ 3V, VCM=3V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 270: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

270

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.131. Raw data for Positive Input Bias Current @ 3V, VCM=3V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=3V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.79E-07 4.12E-07 4.41E-07 4.64E-07 5.09E-07 4.68E-07 4.46E-07879 3.78E-07 4.68E-07 5.17E-07 5.24E-07 5.84E-07 5.49E-07 5.28E-07882 3.79E-07 4.28E-07 4.42E-07 4.65E-07 5.01E-07 4.65E-07 4.45E-07883 4.50E-07 4.80E-07 5.08E-07 5.69E-07 5.84E-07 5.40E-07 5.13E-07885 4.44E-07 4.73E-07 5.03E-07 5.45E-07 5.75E-07 5.34E-07 5.07E-07886 3.84E-07 4.14E-07 4.46E-07 4.68E-07 5.10E-07 4.94E-07 4.43E-07887 4.40E-07 4.67E-07 4.98E-07 5.22E-07 5.70E-07 5.51E-07 4.96E-07891 4.33E-07 4.66E-07 4.93E-07 5.21E-07 5.62E-07 5.47E-07 4.89E-07892 4.45E-07 4.79E-07 5.10E-07 5.36E-07 5.80E-07 5.65E-07 5.03E-07895 3.98E-07 4.26E-07 4.57E-07 4.82E-07 5.28E-07 5.13E-07 4.55E-07896 4.02E-07 4.00E-07 4.00E-07 4.01E-07 4.00E-07 4.03E-07 4.01E-07

Biased StatisticsAverage Biased 4.06E-07 4.52E-07 4.82E-07 5.13E-07 5.51E-07 5.11E-07 4.88E-07Std Dev Biased 3.74E-08 3.02E-08 3.74E-08 4.76E-08 4.20E-08 4.11E-08 3.92E-08Ps90%/90% (+KTL) Biased 5.08E-07 5.35E-07 5.85E-07 6.44E-07 6.66E-07 6.24E-07 5.95E-07Ps90%/90% (-KTL) Biased 3.03E-07 3.69E-07 3.79E-07 3.83E-07 4.35E-07 3.98E-07 3.81E-07Un-Biased StatisticsAverage Un-Biased 4.20E-07 4.51E-07 4.81E-07 5.06E-07 5.50E-07 5.34E-07 4.77E-07Std Dev Un-Biased 2.73E-08 2.84E-08 2.76E-08 2.92E-08 2.99E-08 2.91E-08 2.67E-08Ps90%/90% (+KTL) Un-Biased 4.95E-07 5.28E-07 5.56E-07 5.86E-07 6.32E-07 6.14E-07 5.50E-07Ps90%/90% (-KTL) Un-Biased 3.45E-07 3.73E-07 4.05E-07 4.26E-07 4.68E-07 4.54E-07 4.04E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 271: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

271

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

3V,

VC

M=3

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.132. Plot of Positive Input Bias Current @ 3V, VCM=3V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 272: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

272

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.132. Raw data for Positive Input Bias Current @ 3V, VCM=3V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 3V, VCM=3V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.82E-07 4.13E-07 4.45E-07 4.68E-07 5.11E-07 4.70E-07 4.47E-07879 3.82E-07 4.37E-07 4.91E-07 4.96E-07 5.51E-07 5.12E-07 4.87E-07882 4.31E-07 4.80E-07 4.96E-07 5.20E-07 5.59E-07 5.21E-07 4.96E-07883 4.59E-07 4.92E-07 5.20E-07 5.77E-07 5.90E-07 5.48E-07 5.23E-07885 3.88E-07 4.20E-07 4.52E-07 4.89E-07 5.22E-07 4.82E-07 4.58E-07886 3.90E-07 4.16E-07 4.47E-07 4.72E-07 5.16E-07 5.02E-07 4.44E-07887 4.38E-07 4.68E-07 4.99E-07 5.23E-07 5.63E-07 5.50E-07 4.92E-07891 4.48E-07 4.83E-07 5.05E-07 5.31E-07 5.76E-07 5.59E-07 5.01E-07892 4.60E-07 4.90E-07 5.19E-07 5.49E-07 5.97E-07 5.81E-07 5.17E-07895 4.37E-07 4.68E-07 4.99E-07 5.25E-07 5.73E-07 5.57E-07 4.93E-07896 4.29E-07 4.35E-07 4.29E-07 4.30E-07 4.29E-07 4.32E-07 4.29E-07

Biased StatisticsAverage Biased 4.08E-07 4.48E-07 4.81E-07 5.10E-07 5.47E-07 5.07E-07 4.82E-07Std Dev Biased 3.49E-08 3.57E-08 3.18E-08 4.15E-08 3.13E-08 3.12E-08 3.04E-08Ps90%/90% (+KTL) Biased 5.04E-07 5.46E-07 5.68E-07 6.24E-07 6.32E-07 5.92E-07 5.66E-07Ps90%/90% (-KTL) Biased 3.13E-07 3.51E-07 3.94E-07 3.96E-07 4.61E-07 4.21E-07 3.99E-07Un-Biased StatisticsAverage Un-Biased 4.35E-07 4.65E-07 4.94E-07 5.20E-07 5.65E-07 5.50E-07 4.89E-07Std Dev Un-Biased 2.67E-08 2.89E-08 2.75E-08 2.88E-08 3.00E-08 2.89E-08 2.72E-08Ps90%/90% (+KTL) Un-Biased 5.08E-07 5.44E-07 5.69E-07 5.99E-07 6.47E-07 6.29E-07 5.64E-07Ps90%/90% (-KTL) Un-Biased 3.62E-07 3.86E-07 4.19E-07 4.41E-07 4.83E-07 4.70E-07 4.15E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 273: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

273

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=3V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.133. Plot of Negative Input Bias Current @ 3V, VCM=3V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 274: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

274

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.133. Raw data for Negative Input Bias Current @ 3V, VCM=3V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=3V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.70E-07 4.02E-07 4.34E-07 4.60E-07 5.00E-07 4.61E-07 4.24E-07879 3.69E-07 4.32E-07 4.60E-07 4.89E-07 5.35E-07 4.97E-07 4.61E-07882 4.12E-07 4.45E-07 4.74E-07 5.00E-07 5.42E-07 5.01E-07 4.62E-07883 4.49E-07 4.83E-07 5.13E-07 5.34E-07 5.78E-07 5.37E-07 4.95E-07885 4.03E-07 4.29E-07 4.65E-07 4.96E-07 5.30E-07 4.93E-07 4.49E-07886 3.95E-07 4.23E-07 4.55E-07 4.80E-07 5.24E-07 5.09E-07 4.53E-07887 4.14E-07 4.44E-07 4.75E-07 5.01E-07 5.42E-07 5.28E-07 4.70E-07891 4.26E-07 4.54E-07 4.82E-07 5.09E-07 5.49E-07 5.35E-07 4.77E-07892 4.60E-07 4.92E-07 5.23E-07 5.52E-07 5.97E-07 5.81E-07 5.20E-07895 4.33E-07 4.62E-07 4.95E-07 5.21E-07 5.69E-07 5.52E-07 4.90E-07896 4.26E-07 4.28E-07 4.27E-07 4.26E-07 4.28E-07 4.30E-07 4.28E-07

Biased StatisticsAverage Biased 4.01E-07 4.38E-07 4.69E-07 4.96E-07 5.37E-07 4.98E-07 4.58E-07Std Dev Biased 3.32E-08 2.93E-08 2.86E-08 2.63E-08 2.82E-08 2.70E-08 2.56E-08Ps90%/90% (+KTL) Biased 4.92E-07 5.19E-07 5.48E-07 5.68E-07 6.14E-07 5.72E-07 5.28E-07Ps90%/90% (-KTL) Biased 3.10E-07 3.58E-07 3.91E-07 4.24E-07 4.60E-07 4.24E-07 3.88E-07Un-Biased StatisticsAverage Un-Biased 4.26E-07 4.55E-07 4.86E-07 5.13E-07 5.56E-07 5.41E-07 4.82E-07Std Dev Un-Biased 2.40E-08 2.52E-08 2.53E-08 2.65E-08 2.78E-08 2.73E-08 2.52E-08Ps90%/90% (+KTL) Un-Biased 4.92E-07 5.24E-07 5.55E-07 5.85E-07 6.32E-07 6.16E-07 5.51E-07Ps90%/90% (-KTL) Un-Biased 3.60E-07 3.86E-07 4.17E-07 4.40E-07 4.80E-07 4.66E-07 4.13E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 275: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

275

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=3V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.134. Plot of Negative Input Bias Current @ 3V, VCM=3V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 276: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

276

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.134. Raw data for Negative Input Bias Current @ 3V, VCM=3V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=3V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.99E-07 4.34E-07 4.68E-07 4.92E-07 5.32E-07 4.93E-07 4.56E-07879 3.97E-07 4.70E-07 4.94E-07 5.19E-07 5.72E-07 5.39E-07 5.04E-07882 3.84E-07 4.12E-07 4.41E-07 4.66E-07 5.06E-07 4.70E-07 4.34E-07883 4.59E-07 4.93E-07 5.23E-07 5.45E-07 5.89E-07 5.50E-07 5.06E-07885 4.35E-07 4.68E-07 4.97E-07 5.30E-07 5.65E-07 5.29E-07 4.86E-07886 3.97E-07 4.24E-07 4.52E-07 4.76E-07 5.16E-07 5.04E-07 4.51E-07887 4.49E-07 4.74E-07 5.04E-07 5.29E-07 5.74E-07 5.60E-07 5.01E-07891 4.19E-07 4.51E-07 4.78E-07 5.03E-07 5.44E-07 5.31E-07 4.78E-07892 4.41E-07 4.75E-07 5.05E-07 5.32E-07 5.75E-07 5.61E-07 5.01E-07895 3.89E-07 4.20E-07 4.50E-07 4.76E-07 5.22E-07 5.07E-07 4.49E-07896 4.22E-07 4.24E-07 4.22E-07 4.23E-07 4.23E-07 4.25E-07 4.23E-07

Biased StatisticsAverage Biased 4.15E-07 4.56E-07 4.84E-07 5.10E-07 5.53E-07 5.16E-07 4.77E-07Std Dev Biased 3.13E-08 3.18E-08 3.10E-08 3.14E-08 3.32E-08 3.35E-08 3.15E-08Ps90%/90% (+KTL) Biased 5.01E-07 5.43E-07 5.70E-07 5.96E-07 6.44E-07 6.08E-07 5.64E-07Ps90%/90% (-KTL) Biased 3.29E-07 3.68E-07 3.99E-07 4.24E-07 4.62E-07 4.24E-07 3.91E-07Un-Biased StatisticsAverage Un-Biased 4.19E-07 4.49E-07 4.78E-07 5.03E-07 5.46E-07 5.33E-07 4.76E-07Std Dev Un-Biased 2.63E-08 2.63E-08 2.65E-08 2.73E-08 2.79E-08 2.74E-08 2.55E-08Ps90%/90% (+KTL) Un-Biased 4.91E-07 5.21E-07 5.50E-07 5.78E-07 6.23E-07 6.08E-07 5.46E-07Ps90%/90% (-KTL) Un-Biased 3.47E-07 3.77E-07 4.05E-07 4.29E-07 4.69E-07 4.57E-07 4.06E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 277: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

277

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=3V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.135. Plot of Negative Input Bias Current @ 3V, VCM=3V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 278: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

278

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.135. Raw data for Negative Input Bias Current @ 3V, VCM=3V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=3V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.85E-07 4.16E-07 4.48E-07 4.71E-07 5.13E-07 4.74E-07 4.37E-07879 3.86E-07 4.75E-07 5.23E-07 5.27E-07 5.79E-07 5.47E-07 5.11E-07882 3.88E-07 4.36E-07 4.50E-07 4.73E-07 5.12E-07 4.77E-07 4.39E-07883 4.42E-07 4.73E-07 5.03E-07 5.56E-07 5.73E-07 5.34E-07 4.91E-07885 4.47E-07 4.79E-07 5.08E-07 5.44E-07 5.78E-07 5.37E-07 4.95E-07886 3.90E-07 4.16E-07 4.46E-07 4.68E-07 5.10E-07 4.97E-07 4.44E-07887 4.46E-07 4.72E-07 5.01E-07 5.27E-07 5.69E-07 5.56E-07 5.00E-07891 4.19E-07 4.50E-07 4.77E-07 5.04E-07 5.44E-07 5.31E-07 4.78E-07892 4.51E-07 4.85E-07 5.17E-07 5.42E-07 5.82E-07 5.69E-07 5.10E-07895 4.10E-07 4.41E-07 4.72E-07 4.96E-07 5.41E-07 5.28E-07 4.70E-07896 4.05E-07 4.07E-07 4.06E-07 4.05E-07 4.06E-07 4.08E-07 4.06E-07

Biased StatisticsAverage Biased 4.09E-07 4.56E-07 4.86E-07 5.14E-07 5.51E-07 5.14E-07 4.75E-07Std Dev Biased 3.19E-08 2.80E-08 3.50E-08 4.00E-08 3.53E-08 3.53E-08 3.43E-08Ps90%/90% (+KTL) Biased 4.97E-07 5.32E-07 5.82E-07 6.24E-07 6.48E-07 6.10E-07 5.69E-07Ps90%/90% (-KTL) Biased 3.22E-07 3.79E-07 3.91E-07 4.04E-07 4.54E-07 4.17E-07 3.81E-07Un-Biased StatisticsAverage Un-Biased 4.23E-07 4.53E-07 4.83E-07 5.07E-07 5.49E-07 5.36E-07 4.80E-07Std Dev Un-Biased 2.55E-08 2.69E-08 2.73E-08 2.88E-08 2.77E-08 2.77E-08 2.59E-08Ps90%/90% (+KTL) Un-Biased 4.93E-07 5.27E-07 5.57E-07 5.86E-07 6.25E-07 6.12E-07 5.51E-07Ps90%/90% (-KTL) Un-Biased 3.53E-07 3.79E-07 4.08E-07 4.28E-07 4.73E-07 4.60E-07 4.09E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 279: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

279

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 3

V, V

CM

=3V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.136. Plot of Negative Input Bias Current @ 3V, VCM=3V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 280: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

280

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.136. Raw data for Negative Input Bias Current @ 3V, VCM=3V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 3V, VCM=3V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.87E-07 4.19E-07 4.49E-07 4.72E-07 5.14E-07 4.77E-07 4.40E-07879 3.86E-07 4.48E-07 5.00E-07 5.05E-07 5.53E-07 5.16E-07 4.78E-07882 4.19E-07 4.67E-07 4.83E-07 5.06E-07 5.47E-07 5.08E-07 4.68E-07883 4.60E-07 4.92E-07 5.20E-07 5.76E-07 5.89E-07 5.52E-07 5.05E-07885 3.86E-07 4.16E-07 4.49E-07 4.81E-07 5.16E-07 4.77E-07 4.37E-07886 3.91E-07 4.24E-07 4.49E-07 4.76E-07 5.20E-07 5.03E-07 4.50E-07887 4.21E-07 4.52E-07 4.83E-07 5.09E-07 5.50E-07 5.37E-07 4.77E-07891 4.36E-07 4.64E-07 4.91E-07 5.15E-07 5.58E-07 5.44E-07 4.86E-07892 4.69E-07 4.99E-07 5.28E-07 5.57E-07 6.03E-07 5.88E-07 5.26E-07895 4.33E-07 4.65E-07 4.96E-07 5.23E-07 5.72E-07 5.56E-07 4.93E-07896 4.31E-07 4.30E-07 4.31E-07 4.31E-07 4.35E-07 4.36E-07 4.31E-07

Biased StatisticsAverage Biased 4.08E-07 4.48E-07 4.80E-07 5.08E-07 5.44E-07 5.06E-07 4.66E-07Std Dev Biased 3.27E-08 3.23E-08 3.14E-08 4.10E-08 3.08E-08 3.14E-08 2.84E-08Ps90%/90% (+KTL) Biased 4.97E-07 5.37E-07 5.66E-07 6.20E-07 6.28E-07 5.92E-07 5.44E-07Ps90%/90% (-KTL) Biased 3.18E-07 3.60E-07 3.94E-07 3.96E-07 4.60E-07 4.20E-07 3.88E-07Un-Biased StatisticsAverage Un-Biased 4.30E-07 4.61E-07 4.89E-07 5.16E-07 5.60E-07 5.45E-07 4.87E-07Std Dev Un-Biased 2.85E-08 2.72E-08 2.83E-08 2.89E-08 3.03E-08 3.08E-08 2.77E-08Ps90%/90% (+KTL) Un-Biased 5.08E-07 5.35E-07 5.67E-07 5.95E-07 6.43E-07 6.30E-07 5.63E-07Ps90%/90% (-KTL) Un-Biased 3.52E-07 3.86E-07 4.12E-07 4.37E-07 4.77E-07 4.61E-07 4.11E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 281: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

281

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

1.80E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#1 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.137. Plot of Large Signal Voltage Gain @ 3V #1 (V/mV) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 282: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

282

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.137. Raw data for Large Signal Voltage Gain @ 3V #1 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #1 (V/mV)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.26E+03 1.26E+03 1.46E+03 1.10E+03 8.28E+02 1.14E+03 1.10E+03879 1.41E+03 1.45E+03 1.65E+03 1.05E+03 1.64E+03 1.36E+03 1.78E+03882 1.77E+03 1.67E+03 1.60E+03 1.25E+03 8.34E+02 1.34E+03 1.02E+03883 1.61E+03 5.23E+02 1.58E+03 1.36E+03 1.63E+03 1.20E+03 1.32E+03885 1.65E+03 1.47E+03 1.36E+03 1.27E+03 1.33E+03 1.23E+03 1.13E+03886 1.62E+03 1.15E+03 2.09E+03 1.08E+03 1.83E+03 1.54E+03 1.89E+03887 1.55E+03 1.37E+03 1.43E+03 1.42E+03 9.61E+02 1.09E+03 1.59E+03891 1.48E+03 1.95E+03 1.29E+03 1.39E+03 1.17E+03 1.62E+03 1.39E+03892 1.55E+03 1.35E+03 1.29E+03 1.35E+03 1.32E+03 1.22E+03 1.32E+03895 1.75E+03 1.43E+03 1.07E+03 1.42E+03 1.40E+03 1.27E+03 1.41E+03896 1.43E+03 1.38E+03 1.38E+03 1.45E+03 1.40E+03 1.45E+03 1.46E+03

Biased StatisticsAverage Biased 1.54E+03 1.28E+03 1.53E+03 1.21E+03 1.25E+03 1.25E+03 1.27E+03Std Dev Biased 2.04E+02 4.45E+02 1.17E+02 1.30E+02 4.03E+02 9.21E+01 3.03E+02Ps90%/90% (+KTL) Biased 2.10E+03 2.50E+03 1.85E+03 1.56E+03 2.36E+03 1.51E+03 2.10E+03Ps90%/90% (-KTL) Biased 9.81E+02 5.38E+01 1.21E+03 8.51E+02 1.46E+02 1.00E+03 4.37E+02Un-Biased StatisticsAverage Un-Biased 1.59E+03 1.45E+03 1.43E+03 1.33E+03 1.34E+03 1.35E+03 1.52E+03Std Dev Un-Biased 1.01E+02 2.99E+02 3.86E+02 1.45E+02 3.21E+02 2.25E+02 2.30E+02Ps90%/90% (+KTL) Un-Biased 1.87E+03 2.27E+03 2.49E+03 1.73E+03 2.22E+03 1.97E+03 2.15E+03Ps90%/90% (-KTL) Un-Biased 1.32E+03 6.28E+02 3.74E+02 9.34E+02 4.56E+02 7.33E+02 8.88E+02Specification MIN 5.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS FAIL PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 283: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

283

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

1.80E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#2 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.138. Plot of Large Signal Voltage Gain @ 3V #2 (V/mV) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 284: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

284

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.138. Raw data for Large Signal Voltage Gain @ 3V #2 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #2 (V/mV)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.57E+03 1.58E+03 1.34E+03 1.50E+03 9.50E+02 1.27E+03 1.49E+03879 1.58E+03 1.26E+03 1.48E+03 1.34E+03 1.25E+03 1.32E+03 1.32E+03882 1.55E+03 1.33E+03 1.24E+03 1.26E+03 7.71E+02 1.10E+03 1.29E+03883 1.41E+03 1.21E+03 1.07E+03 1.35E+03 7.76E+02 1.15E+03 1.41E+03885 1.89E+03 1.21E+03 8.39E+02 1.04E+03 1.04E+03 1.24E+03 1.23E+03886 1.30E+03 1.28E+03 1.22E+03 8.55E+02 1.39E+03 9.61E+02 1.13E+03887 7.12E+02 1.19E+03 1.12E+03 9.27E+02 1.13E+03 1.40E+03 1.40E+03891 1.39E+03 1.39E+03 1.18E+03 1.46E+03 1.15E+03 1.18E+03 1.44E+03892 1.24E+03 1.63E+03 1.42E+03 1.96E+03 8.19E+02 1.60E+03 1.12E+03895 1.71E+03 1.83E+03 1.55E+03 1.40E+03 1.35E+03 1.25E+03 1.41E+03896 1.79E+03 2.11E+03 2.27E+03 1.70E+03 1.97E+03 1.75E+03 2.01E+03

Biased StatisticsAverage Biased 1.60E+03 1.32E+03 1.19E+03 1.30E+03 9.57E+02 1.22E+03 1.35E+03Std Dev Biased 1.75E+02 1.52E+02 2.47E+02 1.68E+02 2.00E+02 8.82E+01 1.01E+02Ps90%/90% (+KTL) Biased 2.08E+03 1.73E+03 1.87E+03 1.76E+03 1.50E+03 1.46E+03 1.62E+03Ps90%/90% (-KTL) Biased 1.12E+03 9.00E+02 5.17E+02 8.37E+02 4.09E+02 9.75E+02 1.07E+03Un-Biased StatisticsAverage Un-Biased 1.27E+03 1.46E+03 1.29E+03 1.32E+03 1.17E+03 1.28E+03 1.30E+03Std Dev Un-Biased 3.61E+02 2.64E+02 1.79E+02 4.50E+02 2.27E+02 2.40E+02 1.59E+02Ps90%/90% (+KTL) Un-Biased 2.26E+03 2.19E+03 1.79E+03 2.55E+03 1.79E+03 1.94E+03 1.74E+03Ps90%/90% (-KTL) Un-Biased 2.79E+02 7.38E+02 8.02E+02 8.59E+01 5.46E+02 6.20E+02 8.66E+02Specification MIN 5.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status FAIL PASS PASS FAIL PASS PASS PASS

Total Dose (krad(Si))

Page 285: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

285

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

1.80E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#3 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.139. Plot of Large Signal Voltage Gain @ 3V #3 (V/mV) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 286: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

286

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.139. Raw data for Large Signal Voltage Gain @ 3V #3 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #3 (V/mV)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.81E+03 1.59E+03 1.45E+03 1.51E+03 1.11E+03 1.39E+03 1.50E+03879 1.70E+03 1.31E+03 1.36E+03 1.22E+03 1.09E+03 1.17E+03 1.26E+03882 1.63E+03 1.31E+03 1.46E+03 1.51E+03 8.85E+02 1.16E+03 1.26E+03883 1.86E+03 1.16E+03 1.23E+03 1.32E+03 6.06E+02 9.73E+02 1.28E+03885 1.46E+03 1.15E+03 1.27E+03 1.36E+03 1.08E+03 1.26E+03 1.33E+03886 1.71E+03 1.47E+03 1.41E+03 1.18E+03 1.53E+03 1.11E+03 1.52E+03887 1.51E+03 1.60E+03 6.44E+02 1.16E+03 9.56E+02 1.13E+03 1.36E+03891 1.50E+03 1.48E+03 1.46E+03 1.26E+03 1.48E+03 1.46E+03 1.54E+03892 1.36E+03 1.12E+03 1.17E+03 1.28E+03 1.30E+03 1.34E+03 1.13E+03895 1.70E+03 1.66E+03 1.78E+03 1.84E+03 1.91E+03 1.31E+03 1.54E+03896 1.36E+03 1.41E+03 1.43E+03 1.42E+03 1.42E+03 1.43E+03 1.54E+03

Biased StatisticsAverage Biased 1.69E+03 1.30E+03 1.35E+03 1.38E+03 9.53E+02 1.19E+03 1.33E+03Std Dev Biased 1.57E+02 1.78E+02 1.05E+02 1.27E+02 2.14E+02 1.51E+02 1.00E+02Ps90%/90% (+KTL) Biased 2.13E+03 1.79E+03 1.64E+03 1.73E+03 1.54E+03 1.60E+03 1.60E+03Ps90%/90% (-KTL) Biased 1.26E+03 8.15E+02 1.06E+03 1.03E+03 3.67E+02 7.75E+02 1.05E+03Un-Biased StatisticsAverage Un-Biased 1.56E+03 1.47E+03 1.29E+03 1.34E+03 1.44E+03 1.27E+03 1.42E+03Std Dev Un-Biased 1.51E+02 2.11E+02 4.24E+02 2.82E+02 3.47E+02 1.48E+02 1.76E+02Ps90%/90% (+KTL) Un-Biased 1.97E+03 2.05E+03 2.45E+03 2.11E+03 2.39E+03 1.68E+03 1.90E+03Ps90%/90% (-KTL) Un-Biased 1.14E+03 8.87E+02 1.30E+02 5.67E+02 4.84E+02 8.64E+02 9.36E+02Specification MIN 5.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS PASS FAIL PASS PASS PASS PASS

Total Dose (krad(Si))

Page 287: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

287

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E+02

4.00E+02

6.00E+02

8.00E+02

1.00E+03

1.20E+03

1.40E+03

1.60E+03

1.80E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#4 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.140. Plot of Large Signal Voltage Gain @ 3V #4 (V/mV) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 288: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

288

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.140. Raw data for Large Signal Voltage Gain @ 3V #4 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #4 (V/mV)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.51E+03 1.32E+03 1.27E+03 8.78E+02 8.08E+02 1.02E+03 1.17E+03879 1.23E+03 1.45E+03 1.60E+03 1.33E+03 1.37E+03 1.47E+03 2.13E+03882 1.51E+03 1.27E+03 1.22E+03 1.49E+03 9.73E+02 1.33E+03 1.16E+03883 1.33E+03 1.78E+03 1.21E+03 1.12E+03 1.97E+03 1.23E+03 1.20E+03885 1.60E+03 1.52E+03 1.26E+03 1.15E+03 1.47E+03 1.36E+03 1.44E+03886 1.57E+03 1.32E+03 1.55E+03 1.20E+03 1.65E+03 1.41E+03 1.15E+03887 1.45E+03 1.59E+03 1.34E+03 1.64E+03 1.26E+03 1.32E+03 1.43E+03891 1.36E+03 1.50E+03 1.55E+03 1.56E+03 1.15E+03 1.31E+03 1.46E+03892 1.66E+03 2.03E+03 1.71E+03 1.53E+03 1.04E+03 1.31E+03 1.57E+03895 1.51E+03 1.66E+03 1.62E+03 1.59E+03 9.90E+02 1.64E+03 1.81E+03896 1.46E+03 1.38E+03 1.15E+03 1.79E+03 1.83E+03 1.48E+03 1.35E+03

Biased StatisticsAverage Biased 1.44E+03 1.47E+03 1.31E+03 1.19E+03 1.32E+03 1.28E+03 1.42E+03Std Dev Biased 1.47E+02 2.02E+02 1.63E+02 2.30E+02 4.55E+02 1.70E+02 4.14E+02Ps90%/90% (+KTL) Biased 1.84E+03 2.02E+03 1.76E+03 1.82E+03 2.57E+03 1.75E+03 2.56E+03Ps90%/90% (-KTL) Biased 1.03E+03 9.13E+02 8.65E+02 5.61E+02 7.02E+01 8.17E+02 2.88E+02Un-Biased StatisticsAverage Un-Biased 1.51E+03 1.62E+03 1.55E+03 1.50E+03 1.22E+03 1.40E+03 1.48E+03Std Dev Un-Biased 1.17E+02 2.60E+02 1.36E+02 1.75E+02 2.61E+02 1.44E+02 2.39E+02Ps90%/90% (+KTL) Un-Biased 1.83E+03 2.33E+03 1.93E+03 1.98E+03 1.93E+03 1.79E+03 2.14E+03Ps90%/90% (-KTL) Un-Biased 1.19E+03 9.07E+02 1.18E+03 1.02E+03 5.05E+02 1.00E+03 8.28E+02Specification MIN 5.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS PASS PASS PASS FAIL PASS FAIL

Total Dose (krad(Si))

Page 289: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

289

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.08E+02

1.10E+02

1.12E+02

1.14E+02

1.16E+02

1.18E+02

1.20E+02

1.22E+02

1.24E+02

1.26E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.141. Plot of Large Signal Voltage Gain @ 3V #1 (dB) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 290: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

290

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.141. Raw data for Large Signal Voltage Gain @ 3V #1 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #1 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.22E+02 1.22E+02 1.23E+02 1.21E+02 1.18E+02 1.21E+02 1.21E+02879 1.23E+02 1.23E+02 1.24E+02 1.20E+02 1.24E+02 1.23E+02 1.25E+02882 1.25E+02 1.24E+02 1.24E+02 1.22E+02 1.18E+02 1.23E+02 1.20E+02883 1.24E+02 1.14E+02 1.24E+02 1.23E+02 1.24E+02 1.22E+02 1.22E+02885 1.28E+02 1.23E+02 1.23E+02 1.22E+02 1.22E+02 1.22E+02 1.21E+02886 1.24E+02 1.21E+02 1.26E+02 1.21E+02 1.25E+02 1.24E+02 1.26E+02887 1.24E+02 1.23E+02 1.23E+02 1.23E+02 1.20E+02 1.21E+02 1.24E+02891 1.23E+02 1.26E+02 1.22E+02 1.23E+02 1.21E+02 1.24E+02 1.23E+02892 1.24E+02 1.23E+02 1.22E+02 1.23E+02 1.22E+02 1.22E+02 1.22E+02895 1.25E+02 1.23E+02 1.21E+02 1.23E+02 1.23E+02 1.22E+02 1.23E+02896 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.23E+02

Biased StatisticsAverage Biased 1.25E+02 1.21E+02 1.24E+02 1.22E+02 1.22E+02 1.22E+02 1.22E+02Std Dev Biased 2.49E+00 4.07E+00 6.77E-01 9.44E-01 2.98E+00 6.38E-01 1.91E+00Ps90%/90% (+KTL) Biased 1.31E+02 1.33E+02 1.26E+02 1.24E+02 1.30E+02 1.24E+02 1.27E+02Ps90%/90% (-KTL) Biased 1.18E+02 1.10E+02 1.22E+02 1.19E+02 1.13E+02 1.20E+02 1.17E+02Un-Biased StatisticsAverage Un-Biased 1.24E+02 1.23E+02 1.23E+02 1.22E+02 1.22E+02 1.23E+02 1.24E+02Std Dev Un-Biased 5.40E-01 1.68E+00 2.15E+00 1.02E+00 2.05E+00 1.45E+00 1.25E+00Ps90%/90% (+KTL) Un-Biased 1.26E+02 1.28E+02 1.29E+02 1.25E+02 1.28E+02 1.26E+02 1.27E+02Ps90%/90% (-KTL) Un-Biased 1.23E+02 1.18E+02 1.17E+02 1.20E+02 1.17E+02 1.19E+02 1.20E+02Specification MIN 1.14E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 291: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

291

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.08E+02

1.10E+02

1.12E+02

1.14E+02

1.16E+02

1.18E+02

1.20E+02

1.22E+02

1.24E+02

1.26E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.142. Plot of Large Signal Voltage Gain @ 3V #2 (dB) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 292: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

292

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.142. Raw data for Large Signal Voltage Gain @ 3V #2 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #2 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E+02 1.24E+02 1.23E+02 1.24E+02 1.20E+02 1.22E+02 1.23E+02879 1.24E+02 1.22E+02 1.23E+02 1.23E+02 1.22E+02 1.22E+02 1.22E+02882 1.24E+02 1.22E+02 1.22E+02 1.22E+02 1.18E+02 1.21E+02 1.22E+02883 1.23E+02 1.22E+02 1.21E+02 1.23E+02 1.18E+02 1.21E+02 1.23E+02885 1.26E+02 1.22E+02 1.18E+02 1.20E+02 1.20E+02 1.22E+02 1.22E+02886 1.22E+02 1.22E+02 1.22E+02 1.19E+02 1.23E+02 1.20E+02 1.21E+02887 1.17E+02 1.21E+02 1.21E+02 1.19E+02 1.21E+02 1.23E+02 1.23E+02891 1.23E+02 1.23E+02 1.21E+02 1.23E+02 1.21E+02 1.21E+02 1.23E+02892 1.22E+02 1.24E+02 1.23E+02 1.26E+02 1.18E+02 1.24E+02 1.21E+02895 1.25E+02 1.25E+02 1.24E+02 1.23E+02 1.23E+02 1.22E+02 1.23E+02896 1.25E+02 1.26E+02 1.27E+02 1.25E+02 1.26E+02 1.25E+02 1.26E+02

Biased StatisticsAverage Biased 1.24E+02 1.22E+02 1.21E+02 1.22E+02 1.19E+02 1.22E+02 1.23E+02Std Dev Biased 9.16E-01 9.53E-01 1.91E+00 1.17E+00 1.77E+00 6.35E-01 6.45E-01Ps90%/90% (+KTL) Biased 1.27E+02 1.25E+02 1.27E+02 1.25E+02 1.24E+02 1.23E+02 1.24E+02Ps90%/90% (-KTL) Biased 1.22E+02 1.20E+02 1.16E+02 1.19E+02 1.15E+02 1.20E+02 1.21E+02Un-Biased StatisticsAverage Un-Biased 1.22E+02 1.23E+02 1.22E+02 1.22E+02 1.21E+02 1.22E+02 1.22E+02Std Dev Un-Biased 2.83E+00 1.54E+00 1.18E+00 2.99E+00 1.83E+00 1.66E+00 1.09E+00Ps90%/90% (+KTL) Un-Biased 1.29E+02 1.27E+02 1.25E+02 1.30E+02 1.26E+02 1.27E+02 1.25E+02Ps90%/90% (-KTL) Un-Biased 1.14E+02 1.19E+02 1.19E+02 1.14E+02 1.16E+02 1.17E+02 1.19E+02Specification MIN 1.14E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status FAIL PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 293: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

293

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.08E+02

1.10E+02

1.12E+02

1.14E+02

1.16E+02

1.18E+02

1.20E+02

1.22E+02

1.24E+02

1.26E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.143. Plot of Large Signal Voltage Gain @ 3V #3 (dB) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 294: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

294

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.143. Raw data for Large Signal Voltage Gain @ 3V #3 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #3 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.25E+02 1.24E+02 1.23E+02 1.24E+02 1.21E+02 1.23E+02 1.24E+02879 1.25E+02 1.22E+02 1.23E+02 1.22E+02 1.21E+02 1.21E+02 1.22E+02882 1.24E+02 1.22E+02 1.23E+02 1.24E+02 1.19E+02 1.21E+02 1.22E+02883 1.25E+02 1.21E+02 1.22E+02 1.22E+02 1.16E+02 1.20E+02 1.22E+02885 1.23E+02 1.21E+02 1.22E+02 1.23E+02 1.21E+02 1.22E+02 1.22E+02886 1.25E+02 1.23E+02 1.23E+02 1.21E+02 1.24E+02 1.21E+02 1.24E+02887 1.24E+02 1.24E+02 1.16E+02 1.21E+02 1.20E+02 1.21E+02 1.23E+02891 1.24E+02 1.23E+02 1.23E+02 1.22E+02 1.23E+02 1.23E+02 1.24E+02892 1.23E+02 1.21E+02 1.21E+02 1.22E+02 1.22E+02 1.23E+02 1.21E+02895 1.25E+02 1.24E+02 1.25E+02 1.25E+02 1.26E+02 1.22E+02 1.24E+02896 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.23E+02 1.24E+02

Biased StatisticsAverage Biased 1.25E+02 1.22E+02 1.23E+02 1.23E+02 1.19E+02 1.21E+02 1.22E+02Std Dev Biased 8.26E-01 1.14E+00 6.80E-01 8.08E-01 2.23E+00 1.13E+00 6.32E-01Ps90%/90% (+KTL) Biased 1.27E+02 1.25E+02 1.24E+02 1.25E+02 1.25E+02 1.25E+02 1.24E+02Ps90%/90% (-KTL) Biased 1.22E+02 1.19E+02 1.21E+02 1.21E+02 1.13E+02 1.18E+02 1.21E+02Un-Biased StatisticsAverage Un-Biased 1.24E+02 1.23E+02 1.22E+02 1.22E+02 1.23E+02 1.22E+02 1.23E+02Std Dev Un-Biased 8.48E-01 1.35E+00 3.38E+00 1.65E+00 2.21E+00 1.02E+00 1.15E+00Ps90%/90% (+KTL) Un-Biased 1.26E+02 1.27E+02 1.31E+02 1.27E+02 1.29E+02 1.25E+02 1.26E+02Ps90%/90% (-KTL) Un-Biased 1.21E+02 1.20E+02 1.12E+02 1.18E+02 1.17E+02 1.19E+02 1.20E+02Specification MIN 1.14E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 295: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

295

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.08E+02

1.10E+02

1.12E+02

1.14E+02

1.16E+02

1.18E+02

1.20E+02

1.22E+02

1.24E+02

1.26E+02

1.28E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

3V

#4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.144. Plot of Large Signal Voltage Gain @ 3V #4 (dB) versus total dose. The data show somedegradation with radiation, however it is not sufficient for any of the units-under-test to exceed specification.The solid diamonds are the average of the measured data points for the sample irradiated under electrical biaswhile the shaded diamonds are the average of the measured data points for the units irradiated with all pinstied to ground. The black lines (solid and/or dashed) are the average of the data points after application of theKTL statistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 296: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

296

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.144. Raw data for Large Signal Voltage Gain @ 3V #4 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 3V #4 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E+02 1.22E+02 1.22E+02 1.19E+02 1.18E+02 1.20E+02 1.21E+02879 1.22E+02 1.23E+02 1.24E+02 1.22E+02 1.23E+02 1.23E+02 1.27E+02882 1.24E+02 1.22E+02 1.22E+02 1.23E+02 1.20E+02 1.22E+02 1.21E+02883 1.23E+02 1.25E+02 1.22E+02 1.21E+02 1.26E+02 1.22E+02 1.22E+02885 1.24E+02 1.24E+02 1.22E+02 1.21E+02 1.23E+02 1.23E+02 1.23E+02886 1.24E+02 1.22E+02 1.24E+02 1.22E+02 1.24E+02 1.23E+02 1.21E+02887 1.23E+02 1.24E+02 1.23E+02 1.24E+02 1.22E+02 1.22E+02 1.23E+02891 1.23E+02 1.24E+02 1.24E+02 1.24E+02 1.21E+02 1.22E+02 1.23E+02892 1.24E+02 1.26E+02 1.25E+02 1.24E+02 1.20E+02 1.22E+02 1.24E+02895 1.24E+02 1.31E+02 1.24E+02 1.24E+02 1.20E+02 1.24E+02 1.25E+02896 1.23E+02 1.23E+02 1.21E+02 1.25E+02 1.25E+02 1.23E+02 1.23E+02

Biased StatisticsAverage Biased 1.23E+02 1.23E+02 1.22E+02 1.21E+02 1.22E+02 1.22E+02 1.23E+02Std Dev Biased 9.09E-01 1.16E+00 1.01E+00 1.73E+00 3.05E+00 1.20E+00 2.24E+00Ps90%/90% (+KTL) Biased 1.26E+02 1.26E+02 1.25E+02 1.26E+02 1.30E+02 1.25E+02 1.29E+02Ps90%/90% (-KTL) Biased 1.21E+02 1.20E+02 1.20E+02 1.17E+02 1.14E+02 1.19E+02 1.17E+02Un-Biased StatisticsAverage Un-Biased 1.24E+02 1.25E+02 1.24E+02 1.23E+02 1.22E+02 1.23E+02 1.23E+02Std Dev Un-Biased 6.77E-01 3.51E+00 7.86E-01 1.09E+00 1.74E+00 8.54E-01 1.43E+00Ps90%/90% (+KTL) Un-Biased 1.25E+02 1.35E+02 1.26E+02 1.26E+02 1.26E+02 1.25E+02 1.27E+02Ps90%/90% (-KTL) Un-Biased 1.22E+02 1.16E+02 1.22E+02 1.20E+02 1.17E+02 1.21E+02 1.19E+02Specification MIN 1.14E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 297: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

297

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

3V

#1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.145. Plot of Common Mode Rejection Ratio @ 3V #1 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 298: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

298

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.145. Raw data for Common Mode Rejection Ratio @ 3V #1 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 3V #1 (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.87E+01 7.88E+01 7.89E+01 7.89E+01 7.90E+01 7.91E+01 7.85E+01879 7.87E+01 8.50E+01 8.48E+01 8.46E+01 8.41E+01 8.44E+01 8.43E+01882 7.71E+01 7.72E+01 7.71E+01 7.71E+01 7.70E+01 7.73E+01 7.67E+01883 7.97E+01 7.98E+01 7.97E+01 7.97E+01 7.96E+01 7.97E+01 7.92E+01885 7.92E+01 7.95E+01 7.95E+01 7.93E+01 7.95E+01 7.96E+01 7.95E+01886 8.78E+01 8.81E+01 8.82E+01 8.83E+01 8.84E+01 8.86E+01 8.83E+01887 7.39E+01 7.38E+01 7.38E+01 7.37E+01 7.37E+01 7.37E+01 7.38E+01891 7.94E+01 7.93E+01 7.93E+01 7.93E+01 7.91E+01 7.91E+01 7.94E+01892 8.81E+01 8.80E+01 8.79E+01 8.77E+01 8.74E+01 8.75E+01 8.73E+01895 8.29E+01 8.29E+01 8.28E+01 8.28E+01 8.27E+01 8.28E+01 8.24E+01896 8.29E+01 8.29E+01 8.29E+01 8.29E+01 8.28E+01 8.29E+01 8.29E+01

Biased StatisticsAverage Biased 7.87E+01 8.01E+01 8.00E+01 7.99E+01 7.99E+01 8.00E+01 7.97E+01Std Dev Biased 9.75E-01 2.95E+00 2.88E+00 2.81E+00 2.60E+00 2.65E+00 2.83E+00Ps90%/90% (+KTL) Biased 8.14E+01 8.81E+01 8.79E+01 8.76E+01 8.70E+01 8.73E+01 8.74E+01Ps90%/90% (-KTL) Biased 7.60E+01 7.20E+01 7.21E+01 7.22E+01 7.27E+01 7.27E+01 7.19E+01Un-Biased StatisticsAverage Un-Biased 8.24E+01 8.24E+01 8.24E+01 8.24E+01 8.23E+01 8.24E+01 8.23E+01Std Dev Un-Biased 6.01E+00 6.08E+00 6.10E+00 6.09E+00 6.10E+00 6.15E+00 5.97E+00Ps90%/90% (+KTL) Un-Biased 9.89E+01 9.91E+01 9.91E+01 9.91E+01 9.90E+01 9.92E+01 9.86E+01Ps90%/90% (-KTL) Un-Biased 6.59E+01 6.58E+01 6.57E+01 6.57E+01 6.56E+01 6.55E+01 6.59E+01Specification MIN 7.20E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 299: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

299

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

3V

#2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.146. Plot of Common Mode Rejection Ratio @ 3V #2 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 300: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

300

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.146. Raw data for Common Mode Rejection Ratio @ 3V #2 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 3V #2 (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.57E+01 7.57E+01 7.57E+01 7.58E+01 7.59E+01 7.57E+01 7.52E+01879 7.57E+01 8.43E+01 8.42E+01 8.41E+01 8.36E+01 8.38E+01 8.33E+01882 8.53E+01 8.47E+01 8.44E+01 8.43E+01 8.42E+01 8.44E+01 8.36E+01883 8.62E+01 8.59E+01 8.58E+01 8.57E+01 8.55E+01 8.69E+01 8.48E+01885 8.49E+01 8.48E+01 8.45E+01 8.42E+01 8.39E+01 8.42E+01 8.36E+01886 1.36E+02 1.17E+02 1.12E+02 1.10E+02 1.08E+02 1.07E+02 1.11E+02887 7.88E+01 7.86E+01 7.85E+01 7.84E+01 7.82E+01 7.82E+01 7.84E+01891 1.05E+02 1.02E+02 9.99E+01 9.84E+01 9.68E+01 9.72E+01 1.02E+02892 9.33E+01 9.37E+01 9.41E+01 9.47E+01 9.52E+01 9.54E+01 9.50E+01895 8.99E+01 8.98E+01 8.96E+01 8.94E+01 8.94E+01 8.95E+01 8.92E+01896 9.15E+01 9.14E+01 9.13E+01 9.13E+01 9.14E+01 9.14E+01 9.14E+01

Biased StatisticsAverage Biased 8.16E+01 8.31E+01 8.29E+01 8.28E+01 8.26E+01 8.30E+01 8.21E+01Std Dev Biased 5.39E+00 4.19E+00 4.10E+00 3.99E+00 3.82E+00 4.26E+00 3.92E+00Ps90%/90% (+KTL) Biased 9.63E+01 9.45E+01 9.41E+01 9.37E+01 9.31E+01 9.47E+01 9.28E+01Ps90%/90% (-KTL) Biased 6.68E+01 7.16E+01 7.17E+01 7.19E+01 7.21E+01 7.13E+01 7.13E+01Un-Biased StatisticsAverage Un-Biased 1.01E+02 9.61E+01 9.48E+01 9.42E+01 9.36E+01 9.35E+01 9.51E+01Std Dev Un-Biased 2.20E+01 1.42E+01 1.23E+01 1.16E+01 1.10E+01 1.06E+01 1.23E+01Ps90%/90% (+KTL) Un-Biased 1.61E+02 1.35E+02 1.29E+02 1.26E+02 1.24E+02 1.23E+02 1.29E+02Ps90%/90% (-KTL) Un-Biased 4.03E+01 5.70E+01 6.10E+01 6.23E+01 6.34E+01 6.44E+01 6.13E+01Specification MIN 7.20E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 301: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

301

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

3V

#3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.147. Plot of Common Mode Rejection Ratio @ 3V #3 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 302: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

302

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.147. Raw data for Common Mode Rejection Ratio @ 3V #3 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 3V #3 (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 8.64E+01 8.69E+01 8.70E+01 8.70E+01 8.74E+01 8.72E+01 8.83E+01879 8.64E+01 8.17E+01 8.15E+01 8.13E+01 8.08E+01 8.10E+01 8.05E+01882 8.23E+01 8.20E+01 8.22E+01 8.22E+01 8.23E+01 8.23E+01 8.18E+01883 8.43E+01 8.41E+01 8.40E+01 8.37E+01 8.36E+01 8.39E+01 8.26E+01885 8.10E+01 8.13E+01 8.14E+01 8.10E+01 8.13E+01 8.15E+01 8.03E+01886 7.98E+01 7.97E+01 7.97E+01 7.96E+01 7.96E+01 7.97E+01 7.97E+01887 9.87E+01 9.96E+01 1.02E+02 1.04E+02 1.09E+02 1.10E+02 9.98E+01891 7.82E+01 7.81E+01 7.80E+01 7.80E+01 7.79E+01 7.80E+01 7.79E+01892 8.14E+01 8.14E+01 8.13E+01 8.11E+01 8.09E+01 8.10E+01 8.11E+01895 8.69E+01 8.69E+01 8.69E+01 8.69E+01 8.69E+01 8.68E+01 8.73E+01896 8.44E+01 8.45E+01 8.45E+01 8.45E+01 8.44E+01 8.45E+01 8.45E+01

Biased StatisticsAverage Biased 8.41E+01 8.32E+01 8.32E+01 8.30E+01 8.31E+01 8.32E+01 8.27E+01Std Dev Biased 2.40E+00 2.35E+00 2.38E+00 2.48E+00 2.63E+00 2.51E+00 3.26E+00Ps90%/90% (+KTL) Biased 9.07E+01 8.96E+01 8.97E+01 8.98E+01 9.03E+01 9.01E+01 9.16E+01Ps90%/90% (-KTL) Biased 7.75E+01 7.67E+01 7.67E+01 7.62E+01 7.59E+01 7.63E+01 7.37E+01Un-Biased StatisticsAverage Un-Biased 8.50E+01 8.51E+01 8.55E+01 8.59E+01 8.68E+01 8.71E+01 8.52E+01Std Dev Un-Biased 8.34E+00 8.74E+00 9.62E+00 1.06E+01 1.27E+01 1.33E+01 8.90E+00Ps90%/90% (+KTL) Un-Biased 1.08E+02 1.09E+02 1.12E+02 1.15E+02 1.22E+02 1.23E+02 1.10E+02Ps90%/90% (-KTL) Un-Biased 6.21E+01 6.12E+01 5.91E+01 5.67E+01 5.21E+01 5.07E+01 6.08E+01Specification MIN 7.20E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 303: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

303

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

3V

#4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.148. Plot of Common Mode Rejection Ratio @ 3V #4 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 304: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

304

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.148. Raw data for Common Mode Rejection Ratio @ 3V #4 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 3V #4 (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.73E+01 7.72E+01 7.72E+01 7.71E+01 7.72E+01 7.73E+01 7.71E+01879 7.72E+01 1.13E+02 1.07E+02 1.06E+02 1.02E+02 1.03E+02 1.00E+02882 8.25E+01 8.20E+01 8.21E+01 8.21E+01 8.20E+01 8.21E+01 8.13E+01883 9.20E+01 9.16E+01 9.14E+01 9.11E+01 9.05E+01 9.10E+01 8.90E+01885 9.40E+01 9.35E+01 9.30E+01 9.23E+01 9.24E+01 9.25E+01 9.02E+01886 1.20E+02 1.12E+02 1.08E+02 1.04E+02 1.03E+02 1.04E+02 1.05E+02887 8.30E+01 8.28E+01 8.27E+01 8.27E+01 8.26E+01 8.26E+01 8.25E+01891 1.06E+02 1.03E+02 1.01E+02 9.89E+01 9.71E+01 9.74E+01 1.02E+02892 8.97E+01 9.03E+01 9.08E+01 9.11E+01 9.18E+01 9.18E+01 9.03E+01895 8.27E+01 8.25E+01 8.23E+01 8.22E+01 8.21E+01 8.21E+01 8.25E+01896 9.88E+01 9.88E+01 9.88E+01 9.87E+01 9.79E+01 9.87E+01 9.86E+01

Biased StatisticsAverage Biased 8.46E+01 9.14E+01 9.01E+01 8.97E+01 8.88E+01 8.92E+01 8.76E+01Std Dev Biased 8.00E+00 1.36E+01 1.13E+01 1.10E+01 9.56E+00 1.00E+01 9.00E+00Ps90%/90% (+KTL) Biased 1.07E+02 1.29E+02 1.21E+02 1.20E+02 1.15E+02 1.17E+02 1.12E+02Ps90%/90% (-KTL) Biased 6.27E+01 5.40E+01 5.90E+01 5.96E+01 6.26E+01 6.17E+01 6.29E+01Un-Biased StatisticsAverage Un-Biased 9.62E+01 9.42E+01 9.30E+01 9.18E+01 9.13E+01 9.15E+01 9.26E+01Std Dev Un-Biased 1.62E+01 1.32E+01 1.14E+01 9.74E+00 9.16E+00 9.36E+00 1.08E+01Ps90%/90% (+KTL) Un-Biased 1.41E+02 1.30E+02 1.24E+02 1.19E+02 1.16E+02 1.17E+02 1.22E+02Ps90%/90% (-KTL) Un-Biased 5.17E+01 5.81E+01 6.18E+01 6.51E+01 6.62E+01 6.59E+01 6.30E+01Specification MIN 7.20E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 305: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

305

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

1-4

@ 3

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.149. Plot of Common Mode Rejection Ratio Matching 1-4 @ 3V (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 306: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

306

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.149. Raw data for Common Mode Rejection Ratio Matching 1-4 @ 3V (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Common Mode Rejection Ratio Matching 1-4 @ 3V (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 9.36E+01 9.24E+01 9.25E+01 9.20E+01 9.19E+01 9.22E+01 9.40E+01879 9.35E+01 8.54E+01 8.56E+01 8.54E+01 8.53E+01 8.54E+01 8.58E+01882 8.39E+01 8.46E+01 8.43E+01 8.42E+01 8.42E+01 8.46E+01 8.45E+01883 8.22E+01 8.23E+01 8.23E+01 8.25E+01 8.25E+01 8.25E+01 8.26E+01885 8.10E+01 8.15E+01 8.16E+01 8.15E+01 8.18E+01 8.18E+01 8.25E+01886 8.76E+01 8.76E+01 8.74E+01 8.70E+01 8.70E+01 8.72E+01 8.72E+01887 7.76E+01 7.76E+01 7.76E+01 7.76E+01 7.75E+01 7.76E+01 7.78E+01891 7.98E+01 7.99E+01 8.00E+01 8.02E+01 8.03E+01 8.03E+01 8.01E+01892 8.29E+01 8.31E+01 8.32E+01 8.32E+01 8.33E+01 8.34E+01 8.27E+01895 1.14E+02 1.10E+02 1.08E+02 1.05E+02 1.04E+02 1.05E+02 1.29E+02896 8.44E+01 8.44E+01 8.44E+01 8.44E+01 8.45E+01 8.45E+01 8.44E+01

Biased StatisticsAverage Biased 8.68E+01 8.52E+01 8.52E+01 8.51E+01 8.51E+01 8.53E+01 8.59E+01Std Dev Biased 6.21E+00 4.32E+00 4.35E+00 4.14E+00 4.01E+00 4.12E+00 4.74E+00Ps90%/90% (+KTL) Biased 1.04E+02 9.71E+01 9.72E+01 9.65E+01 9.61E+01 9.66E+01 9.89E+01Ps90%/90% (-KTL) Biased 6.98E+01 7.34E+01 7.33E+01 7.38E+01 7.41E+01 7.40E+01 7.29E+01Un-Biased StatisticsAverage Un-Biased 8.85E+01 8.76E+01 8.72E+01 8.67E+01 8.65E+01 8.66E+01 9.13E+01Std Dev Un-Biased 1.50E+01 1.30E+01 1.22E+01 1.11E+01 1.06E+01 1.07E+01 2.12E+01Ps90%/90% (+KTL) Un-Biased 1.30E+02 1.23E+02 1.21E+02 1.17E+02 1.16E+02 1.16E+02 1.50E+02Ps90%/90% (-KTL) Un-Biased 4.74E+01 5.19E+01 5.39E+01 5.64E+01 5.74E+01 5.74E+01 3.31E+01Specification MIN 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 307: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

307

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

2-3

@ 3

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.150. Plot of Common Mode Rejection Ratio Matching 2-3 @ 3V (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 308: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

308

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.150. Raw data for Common Mode Rejection Ratio Matching 2-3 @ 3V (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Common Mode Rejection Ratio Matching 2-3 @ 3V (dB)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.35E+01 7.36E+01 7.36E+01 7.37E+01 7.39E+01 7.36E+01 7.34E+01879 7.34E+01 9.33E+01 9.28E+01 9.25E+01 9.23E+01 9.23E+01 9.19E+01882 9.31E+01 9.33E+01 9.53E+01 9.54E+01 9.63E+01 9.58E+01 9.62E+01883 9.83E+01 9.88E+01 9.86E+01 9.77E+01 9.79E+01 9.45E+01 9.55E+01885 8.98E+01 9.08E+01 9.19E+01 9.11E+01 9.31E+01 9.28E+01 9.03E+01886 7.98E+01 7.99E+01 7.99E+01 7.99E+01 8.00E+01 8.00E+01 7.95E+01887 7.80E+01 7.78E+01 7.79E+01 7.80E+01 7.80E+01 7.80E+01 7.77E+01891 7.86E+01 7.87E+01 7.88E+01 7.88E+01 7.90E+01 7.90E+01 7.85E+01892 7.95E+01 7.95E+01 7.95E+01 7.94E+01 7.94E+01 7.95E+01 7.95E+01895 9.76E+01 9.80E+01 9.84E+01 9.89E+01 9.91E+01 9.82E+01 1.01E+02896 8.95E+01 8.98E+01 8.97E+01 8.97E+01 8.96E+01 8.98E+01 8.97E+01

Biased StatisticsAverage Biased 8.56E+01 8.99E+01 9.04E+01 9.01E+01 9.07E+01 8.98E+01 8.95E+01Std Dev Biased 1.15E+01 9.62E+00 9.77E+00 9.53E+00 9.69E+00 9.16E+00 9.30E+00Ps90%/90% (+KTL) Biased 1.17E+02 1.16E+02 1.17E+02 1.16E+02 1.17E+02 1.15E+02 1.15E+02Ps90%/90% (-KTL) Biased 5.41E+01 6.36E+01 6.36E+01 6.40E+01 6.41E+01 6.47E+01 6.40E+01Un-Biased StatisticsAverage Un-Biased 8.27E+01 8.28E+01 8.29E+01 8.30E+01 8.31E+01 8.29E+01 8.33E+01Std Dev Un-Biased 8.36E+00 8.53E+00 8.72E+00 8.92E+00 8.98E+00 8.57E+00 1.01E+01Ps90%/90% (+KTL) Un-Biased 1.06E+02 1.06E+02 1.07E+02 1.07E+02 1.08E+02 1.06E+02 1.11E+02Ps90%/90% (-KTL) Un-Biased 5.98E+01 5.94E+01 5.90E+01 5.85E+01 5.84E+01 5.95E+01 5.56E+01Specification MIN 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 309: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

309

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 3

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.151. Plot of Output Voltage Swing High IL= 0mA @ 3V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 310: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

310

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.151. Raw data for Output Voltage Swing High IL= 0mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.77E-03 3.66E-03 3.78E-03 3.68E-03 3.88E-03 3.58E-03 3.60E-03879 3.73E-03 3.66E-03 3.66E-03 3.67E-03 3.83E-03 3.67E-03 3.80E-03882 3.77E-03 3.62E-03 3.68E-03 3.55E-03 3.77E-03 3.56E-03 3.87E-03883 3.65E-03 3.66E-03 3.81E-03 3.82E-03 4.10E-03 3.83E-03 3.91E-03885 3.75E-03 3.69E-03 3.63E-03 3.56E-03 3.68E-03 3.72E-03 3.77E-03886 3.68E-03 3.72E-03 3.71E-03 3.83E-03 3.85E-03 3.70E-03 3.79E-03887 3.80E-03 3.62E-03 3.71E-03 3.88E-03 4.02E-03 3.77E-03 3.79E-03891 3.66E-03 3.60E-03 3.75E-03 3.78E-03 3.85E-03 3.83E-03 3.89E-03892 3.58E-03 3.59E-03 3.76E-03 3.92E-03 3.90E-03 3.83E-03 3.82E-03895 3.72E-03 3.79E-03 3.86E-03 3.83E-03 3.88E-03 3.95E-03 3.86E-03896 3.98E-03 3.99E-03 3.98E-03 3.85E-03 3.98E-03 4.07E-03 4.02E-03

Biased StatisticsAverage Biased 3.73E-03 3.66E-03 3.71E-03 3.66E-03 3.85E-03 3.67E-03 3.79E-03Std Dev Biased 4.98E-05 2.49E-05 7.85E-05 1.10E-04 1.57E-04 1.10E-04 1.20E-04Ps90%/90% (+KTL) Biased 3.87E-03 3.73E-03 3.93E-03 3.96E-03 4.28E-03 3.97E-03 4.12E-03Ps90%/90% (-KTL) Biased 3.60E-03 3.59E-03 3.50E-03 3.36E-03 3.42E-03 3.37E-03 3.46E-03Un-Biased StatisticsAverage Un-Biased 3.69E-03 3.66E-03 3.76E-03 3.85E-03 3.90E-03 3.82E-03 3.83E-03Std Dev Un-Biased 8.07E-05 8.73E-05 6.14E-05 5.36E-05 7.04E-05 9.21E-05 4.42E-05Ps90%/90% (+KTL) Un-Biased 3.91E-03 3.90E-03 3.93E-03 3.99E-03 4.09E-03 4.07E-03 3.95E-03Ps90%/90% (-KTL) Un-Biased 3.47E-03 3.42E-03 3.59E-03 3.70E-03 3.71E-03 3.56E-03 3.71E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 311: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

311

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 3

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.152. Plot of Output Voltage Swing High IL= 0mA @ 3V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 312: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

312

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.152. Raw data for Output Voltage Swing High IL= 0mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.98E-03 3.74E-03 3.80E-03 3.73E-03 3.78E-03 3.56E-03 3.87E-03879 3.80E-03 3.47E-03 3.53E-03 3.55E-03 3.68E-03 3.60E-03 3.69E-03882 3.78E-03 3.67E-03 3.66E-03 3.65E-03 3.98E-03 3.51E-03 3.86E-03883 3.63E-03 3.76E-03 3.68E-03 3.70E-03 4.25E-03 3.60E-03 3.87E-03885 3.68E-03 3.62E-03 3.66E-03 3.68E-03 3.63E-03 3.46E-03 3.64E-03886 3.56E-03 3.66E-03 3.86E-03 3.72E-03 3.71E-03 3.65E-03 3.72E-03887 3.63E-03 3.60E-03 3.68E-03 3.72E-03 3.80E-03 3.68E-03 3.59E-03891 3.73E-03 3.86E-03 3.69E-03 3.77E-03 3.90E-03 3.73E-03 3.79E-03892 3.46E-03 3.62E-03 3.69E-03 3.65E-03 3.77E-03 3.70E-03 3.75E-03895 3.72E-03 3.72E-03 3.78E-03 3.80E-03 3.80E-03 3.85E-03 3.79E-03896 3.80E-03 3.59E-03 3.83E-03 3.61E-03 3.75E-03 3.68E-03 3.84E-03

Biased StatisticsAverage Biased 3.77E-03 3.65E-03 3.67E-03 3.66E-03 3.86E-03 3.55E-03 3.79E-03Std Dev Biased 1.35E-04 1.16E-04 9.58E-05 6.91E-05 2.54E-04 6.07E-05 1.12E-04Ps90%/90% (+KTL) Biased 4.14E-03 3.97E-03 3.93E-03 3.85E-03 4.56E-03 3.71E-03 4.09E-03Ps90%/90% (-KTL) Biased 3.40E-03 3.33E-03 3.40E-03 3.47E-03 3.17E-03 3.38E-03 3.48E-03Un-Biased StatisticsAverage Un-Biased 3.62E-03 3.69E-03 3.74E-03 3.73E-03 3.80E-03 3.72E-03 3.73E-03Std Dev Un-Biased 1.13E-04 1.04E-04 7.84E-05 5.72E-05 6.88E-05 7.73E-05 8.26E-05Ps90%/90% (+KTL) Un-Biased 3.93E-03 3.98E-03 3.96E-03 3.89E-03 3.98E-03 3.93E-03 3.95E-03Ps90%/90% (-KTL) Un-Biased 3.31E-03 3.41E-03 3.52E-03 3.58E-03 3.61E-03 3.51E-03 3.50E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 313: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

313

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 3

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.153. Plot of Output Voltage Swing High IL= 0mA @ 3V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 314: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

314

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.153. Raw data for Output Voltage Swing High IL= 0mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.83E-03 3.82E-03 3.66E-03 3.83E-03 3.70E-03 3.70E-03 3.77E-03879 3.80E-03 3.67E-03 3.58E-03 3.51E-03 3.78E-03 3.50E-03 3.80E-03882 3.88E-03 3.74E-03 3.64E-03 3.68E-03 3.73E-03 3.60E-03 3.84E-03883 3.72E-03 3.72E-03 3.66E-03 3.51E-03 5.32E-03 3.73E-03 3.96E-03885 3.66E-03 3.71E-03 3.64E-03 3.72E-03 3.71E-03 3.65E-03 3.74E-03886 3.72E-03 3.74E-03 3.71E-03 3.77E-03 3.93E-03 3.83E-03 3.82E-03887 3.58E-03 3.60E-03 3.69E-03 3.68E-03 3.78E-03 3.72E-03 3.77E-03891 3.70E-03 3.59E-03 3.68E-03 3.61E-03 3.82E-03 3.65E-03 3.82E-03892 3.60E-03 3.79E-03 3.75E-03 3.63E-03 3.77E-03 3.82E-03 3.79E-03895 3.78E-03 3.82E-03 3.76E-03 3.82E-03 3.78E-03 3.82E-03 3.82E-03896 3.80E-03 3.84E-03 3.76E-03 3.72E-03 3.83E-03 3.75E-03 3.80E-03

Biased StatisticsAverage Biased 3.78E-03 3.73E-03 3.64E-03 3.65E-03 4.05E-03 3.64E-03 3.82E-03Std Dev Biased 8.79E-05 5.54E-05 3.29E-05 1.39E-04 7.12E-04 9.07E-05 8.56E-05Ps90%/90% (+KTL) Biased 4.02E-03 3.88E-03 3.73E-03 4.03E-03 6.00E-03 3.88E-03 4.06E-03Ps90%/90% (-KTL) Biased 3.54E-03 3.58E-03 3.55E-03 3.27E-03 2.10E-03 3.39E-03 3.59E-03Un-Biased StatisticsAverage Un-Biased 3.68E-03 3.71E-03 3.72E-03 3.70E-03 3.82E-03 3.77E-03 3.80E-03Std Dev Un-Biased 8.41E-05 1.07E-04 3.56E-05 9.04E-05 6.66E-05 7.98E-05 2.30E-05Ps90%/90% (+KTL) Un-Biased 3.91E-03 4.00E-03 3.82E-03 3.95E-03 4.00E-03 3.99E-03 3.87E-03Ps90%/90% (-KTL) Un-Biased 3.45E-03 3.41E-03 3.62E-03 3.45E-03 3.63E-03 3.55E-03 3.74E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 315: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

315

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 3

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.154. Plot of Output Voltage Swing High IL= 0mA @ 3V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 316: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

316

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.154. Raw data for Output Voltage Swing High IL= 0mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 3.77E-03 3.60E-03 3.68E-03 3.68E-03 3.73E-03 3.55E-03 3.70E-03879 3.90E-03 3.72E-03 3.59E-03 3.70E-03 3.63E-03 3.68E-03 3.82E-03882 3.65E-03 3.64E-03 3.56E-03 3.75E-03 3.65E-03 3.48E-03 3.84E-03883 3.85E-03 3.77E-03 3.76E-03 3.63E-03 3.68E-03 3.51E-03 3.91E-03885 3.78E-03 3.81E-03 3.71E-03 3.65E-03 3.83E-03 3.77E-03 3.77E-03886 3.77E-03 3.77E-03 3.85E-03 3.67E-03 3.92E-03 3.87E-03 3.86E-03887 3.70E-03 3.91E-03 3.85E-03 3.73E-03 3.77E-03 3.73E-03 3.82E-03891 3.68E-03 3.67E-03 3.86E-03 3.75E-03 3.80E-03 3.87E-03 3.69E-03892 3.82E-03 3.69E-03 3.85E-03 3.87E-03 4.03E-03 3.77E-03 3.84E-03895 3.73E-03 3.71E-03 3.81E-03 3.85E-03 4.15E-03 3.88E-03 3.91E-03896 4.02E-03 3.89E-03 3.98E-03 4.07E-03 4.00E-03 3.77E-03 3.96E-03

Biased StatisticsAverage Biased 3.79E-03 3.71E-03 3.66E-03 3.68E-03 3.70E-03 3.60E-03 3.81E-03Std Dev Biased 9.46E-05 8.76E-05 8.34E-05 4.66E-05 7.99E-05 1.23E-04 7.85E-05Ps90%/90% (+KTL) Biased 4.05E-03 3.95E-03 3.89E-03 3.81E-03 3.92E-03 3.93E-03 4.02E-03Ps90%/90% (-KTL) Biased 3.53E-03 3.47E-03 3.43E-03 3.55E-03 3.48E-03 3.26E-03 3.59E-03Un-Biased StatisticsAverage Un-Biased 3.74E-03 3.75E-03 3.84E-03 3.77E-03 3.93E-03 3.82E-03 3.82E-03Std Dev Un-Biased 5.61E-05 9.70E-05 1.95E-05 8.41E-05 1.59E-04 6.91E-05 8.20E-05Ps90%/90% (+KTL) Un-Biased 3.89E-03 4.02E-03 3.90E-03 4.00E-03 4.37E-03 4.01E-03 4.05E-03Ps90%/90% (-KTL) Un-Biased 3.59E-03 3.48E-03 3.79E-03 3.54E-03 3.50E-03 3.63E-03 3.60E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 317: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

317

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 3

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.155. Plot of Output Voltage Swing High IL= 1mA @ 3V #1 (V) versus total dose. The data show asignificant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 318: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

318

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.155. Raw data for Output Voltage Swing High IL= 1mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 6.82E-02 6.92E-02 7.07E-02 7.14E-02 9.31E-02 7.74E-02 7.07E-02879 6.82E-02 6.99E-02 7.07E-02 7.19E-02 7.09E-02 7.03E-02 7.04E-02882 6.72E-02 6.85E-02 6.99E-02 7.05E-02 9.81E-02 7.90E-02 7.00E-02883 7.05E-02 7.18E-02 7.31E-02 7.37E-02 9.87E-02 8.04E-02 7.34E-02885 6.91E-02 7.04E-02 7.13E-02 7.10E-02 7.32E-02 7.19E-02 7.17E-02886 6.75E-02 6.80E-02 6.83E-02 6.88E-02 6.95E-02 6.90E-02 6.86E-02887 6.86E-02 6.90E-02 6.95E-02 7.00E-02 7.06E-02 7.04E-02 7.01E-02891 6.85E-02 6.90E-02 6.95E-02 7.00E-02 7.05E-02 7.00E-02 6.97E-02892 6.76E-02 6.80E-02 6.86E-02 6.90E-02 7.02E-02 6.98E-02 6.92E-02895 6.99E-02 7.04E-02 7.09E-02 7.13E-02 7.22E-02 7.16E-02 7.12E-02896 7.17E-02 7.15E-02 7.18E-02 7.17E-02 7.18E-02 7.15E-02 7.17E-02

Biased StatisticsAverage Biased 6.86E-02 6.99E-02 7.11E-02 7.17E-02 8.68E-02 7.58E-02 7.12E-02Std Dev Biased 1.23E-03 1.24E-03 1.19E-03 1.22E-03 1.37E-02 4.43E-03 1.36E-03Ps90%/90% (+KTL) Biased 7.20E-02 7.34E-02 7.44E-02 7.50E-02 1.24E-01 8.79E-02 7.50E-02Ps90%/90% (-KTL) Biased 6.52E-02 6.65E-02 6.79E-02 6.83E-02 4.93E-02 6.36E-02 6.75E-02Un-Biased StatisticsAverage Un-Biased 6.84E-02 6.89E-02 6.94E-02 6.98E-02 7.06E-02 7.02E-02 6.98E-02Std Dev Un-Biased 9.79E-04 9.92E-04 9.88E-04 9.70E-04 9.75E-04 9.84E-04 9.82E-04Ps90%/90% (+KTL) Un-Biased 7.11E-02 7.16E-02 7.21E-02 7.25E-02 7.33E-02 7.29E-02 7.25E-02Ps90%/90% (-KTL) Un-Biased 6.57E-02 6.61E-02 6.66E-02 6.72E-02 6.79E-02 6.75E-02 6.71E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 319: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

319

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 3

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.156. Plot of Output Voltage Swing High IL= 1mA @ 3V #2 (V) versus total dose. The data show asignificant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 320: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

320

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.156. Raw data for Output Voltage Swing High IL= 1mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 6.75E-02 6.88E-02 7.01E-02 7.10E-02 8.75E-02 7.58E-02 7.05E-02879 6.77E-02 6.70E-02 6.80E-02 6.90E-02 6.82E-02 6.77E-02 6.76E-02882 6.67E-02 6.80E-02 6.90E-02 7.01E-02 1.02E-01 7.93E-02 6.94E-02883 6.95E-02 7.11E-02 7.27E-02 7.32E-02 1.14E-01 8.18E-02 7.26E-02885 6.81E-02 7.02E-02 7.10E-02 7.06E-02 7.26E-02 7.15E-02 7.10E-02886 6.70E-02 6.70E-02 6.77E-02 6.78E-02 6.85E-02 6.82E-02 6.79E-02887 6.55E-02 6.60E-02 6.64E-02 6.70E-02 6.79E-02 6.73E-02 6.69E-02891 6.57E-02 6.58E-02 6.64E-02 6.66E-02 6.74E-02 6.69E-02 6.65E-02892 6.71E-02 6.76E-02 6.83E-02 6.86E-02 6.95E-02 6.90E-02 6.85E-02895 6.48E-02 6.52E-02 6.55E-02 6.62E-02 6.66E-02 6.64E-02 6.57E-02896 6.85E-02 6.84E-02 6.86E-02 6.84E-02 6.87E-02 6.84E-02 6.87E-02

Biased StatisticsAverage Biased 6.79E-02 6.90E-02 7.02E-02 7.08E-02 8.88E-02 7.52E-02 7.02E-02Std Dev Biased 1.02E-03 1.66E-03 1.81E-03 1.56E-03 1.93E-02 5.72E-03 1.86E-03Ps90%/90% (+KTL) Biased 7.07E-02 7.36E-02 7.51E-02 7.50E-02 1.42E-01 9.09E-02 7.53E-02Ps90%/90% (-KTL) Biased 6.51E-02 6.45E-02 6.52E-02 6.65E-02 3.58E-02 5.95E-02 6.51E-02Un-Biased StatisticsAverage Un-Biased 6.60E-02 6.63E-02 6.69E-02 6.72E-02 6.80E-02 6.76E-02 6.71E-02Std Dev Un-Biased 9.95E-04 9.75E-04 1.09E-03 9.54E-04 1.07E-03 1.04E-03 1.12E-03Ps90%/90% (+KTL) Un-Biased 6.87E-02 6.90E-02 6.98E-02 6.98E-02 7.09E-02 7.04E-02 7.02E-02Ps90%/90% (-KTL) Un-Biased 6.32E-02 6.37E-02 6.39E-02 6.46E-02 6.50E-02 6.47E-02 6.40E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 321: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

321

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

1.80E-01

2.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 3

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.157. Plot of Output Voltage Swing High IL= 1mA @ 3V #3 (V) versus total dose. The data show asignificant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 322: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

322

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.157. Raw data for Output Voltage Swing High IL= 1mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 6.77E-02 6.89E-02 6.99E-02 7.06E-02 8.80E-02 7.51E-02 7.03E-02879 6.76E-02 6.67E-02 6.81E-02 6.92E-02 6.82E-02 6.75E-02 6.75E-02882 6.65E-02 6.81E-02 6.91E-02 6.97E-02 9.15E-02 7.51E-02 6.90E-02883 6.93E-02 7.09E-02 7.26E-02 7.34E-02 1.55E-01 8.79E-02 7.30E-02885 6.84E-02 6.98E-02 7.12E-02 7.05E-02 7.29E-02 7.15E-02 7.10E-02886 6.69E-02 6.71E-02 6.75E-02 6.80E-02 6.87E-02 6.81E-02 6.78E-02887 6.54E-02 6.58E-02 6.62E-02 6.70E-02 6.78E-02 6.74E-02 6.68E-02891 6.50E-02 6.54E-02 6.60E-02 6.63E-02 6.69E-02 6.65E-02 6.62E-02892 6.74E-02 6.80E-02 6.84E-02 6.90E-02 6.97E-02 6.94E-02 6.87E-02895 6.52E-02 6.58E-02 6.62E-02 6.67E-02 6.74E-02 6.69E-02 6.66E-02896 6.80E-02 6.80E-02 6.82E-02 6.81E-02 6.83E-02 6.79E-02 6.82E-02

Biased StatisticsAverage Biased 6.79E-02 6.89E-02 7.02E-02 7.07E-02 9.50E-02 7.54E-02 7.02E-02Std Dev Biased 1.02E-03 1.61E-03 1.75E-03 1.65E-03 3.47E-02 7.66E-03 2.10E-03Ps90%/90% (+KTL) Biased 7.07E-02 7.33E-02 7.50E-02 7.52E-02 1.90E-01 9.64E-02 7.59E-02Ps90%/90% (-KTL) Biased 6.51E-02 6.45E-02 6.54E-02 6.61E-02 -1.73E-04 5.44E-02 6.44E-02Un-Biased StatisticsAverage Un-Biased 6.60E-02 6.64E-02 6.69E-02 6.74E-02 6.81E-02 6.77E-02 6.72E-02Std Dev Un-Biased 1.07E-03 1.08E-03 1.06E-03 1.09E-03 1.12E-03 1.15E-03 1.01E-03Ps90%/90% (+KTL) Un-Biased 6.89E-02 6.94E-02 6.98E-02 7.04E-02 7.11E-02 7.08E-02 7.00E-02Ps90%/90% (-KTL) Un-Biased 6.30E-02 6.34E-02 6.40E-02 6.44E-02 6.50E-02 6.45E-02 6.44E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 323: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

323

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 3

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.158. Plot of Output Voltage Swing High IL= 1mA @ 3V #4 (V) versus total dose. The data show asignificant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 324: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

324

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.158. Raw data for Output Voltage Swing High IL= 1mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 6.84E-02 6.93E-02 7.08E-02 7.15E-02 9.30E-02 7.76E-02 7.08E-02879 6.83E-02 6.94E-02 7.08E-02 7.17E-02 7.07E-02 7.02E-02 7.04E-02882 6.72E-02 6.88E-02 7.00E-02 7.05E-02 9.56E-02 7.80E-02 6.99E-02883 7.03E-02 7.15E-02 7.32E-02 7.37E-02 7.60E-02 7.38E-02 7.34E-02885 6.91E-02 7.04E-02 7.14E-02 7.09E-02 7.29E-02 7.18E-02 7.16E-02886 6.73E-02 6.76E-02 6.81E-02 6.85E-02 6.92E-02 6.87E-02 6.84E-02887 6.86E-02 6.91E-02 6.95E-02 6.99E-02 7.06E-02 7.03E-02 7.02E-02891 6.86E-02 6.90E-02 6.94E-02 7.00E-02 7.07E-02 7.01E-02 6.98E-02892 6.81E-02 6.85E-02 6.90E-02 6.97E-02 7.04E-02 7.01E-02 6.95E-02895 7.02E-02 7.07E-02 7.12E-02 7.16E-02 7.24E-02 7.19E-02 7.15E-02896 7.11E-02 7.11E-02 7.12E-02 7.12E-02 7.11E-02 7.10E-02 7.10E-02

Biased StatisticsAverage Biased 6.87E-02 6.99E-02 7.12E-02 7.17E-02 8.17E-02 7.43E-02 7.12E-02Std Dev Biased 1.13E-03 1.10E-03 1.19E-03 1.23E-03 1.17E-02 3.45E-03 1.37E-03Ps90%/90% (+KTL) Biased 7.18E-02 7.29E-02 7.45E-02 7.50E-02 1.14E-01 8.37E-02 7.50E-02Ps90%/90% (-KTL) Biased 6.56E-02 6.69E-02 6.80E-02 6.83E-02 4.95E-02 6.48E-02 6.74E-02Un-Biased StatisticsAverage Un-Biased 6.86E-02 6.90E-02 6.94E-02 6.99E-02 7.06E-02 7.02E-02 6.99E-02Std Dev Un-Biased 1.07E-03 1.15E-03 1.10E-03 1.08E-03 1.13E-03 1.13E-03 1.12E-03Ps90%/90% (+KTL) Un-Biased 7.15E-02 7.21E-02 7.25E-02 7.29E-02 7.37E-02 7.33E-02 7.29E-02Ps90%/90% (-KTL) Un-Biased 6.56E-02 6.59E-02 6.64E-02 6.70E-02 6.76E-02 6.71E-02 6.68E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 325: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

325

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

3V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.159. Plot of Output Voltage Swing High IL= 2.5mA @ 3V #1 (V) versus total dose. The data showa significant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 326: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

326

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.159. Raw data for Output Voltage Swing High IL= 2.5mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.23E-01 1.25E-01 1.26E-01 1.27E-01 1.60E-01 1.36E-01 1.26E-01879 1.23E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.25E-01 1.26E-01882 1.22E-01 1.23E-01 1.25E-01 1.26E-01 1.69E-01 1.38E-01 1.25E-01883 1.26E-01 1.28E-01 1.29E-01 1.30E-01 1.69E-01 1.40E-01 1.30E-01885 1.25E-01 1.26E-01 1.28E-01 1.27E-01 1.30E-01 1.28E-01 1.28E-01886 1.23E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01887 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01891 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01892 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.25E-01 1.24E-01895 1.25E-01 1.26E-01 1.27E-01 1.27E-01 1.28E-01 1.27E-01 1.27E-01896 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01

Biased StatisticsAverage Biased 1.24E-01 1.25E-01 1.27E-01 1.28E-01 1.51E-01 1.33E-01 1.27E-01Std Dev Biased 1.54E-03 1.67E-03 1.82E-03 1.58E-03 2.13E-02 6.53E-03 1.79E-03Ps90%/90% (+KTL) Biased 1.28E-01 1.30E-01 1.32E-01 1.32E-01 2.10E-01 1.51E-01 1.32E-01Ps90%/90% (-KTL) Biased 1.20E-01 1.21E-01 1.22E-01 1.23E-01 9.25E-02 1.15E-01 1.22E-01Un-Biased StatisticsAverage Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01Std Dev Un-Biased 1.25E-03 1.41E-03 1.37E-03 1.30E-03 1.36E-03 1.32E-03 1.22E-03Ps90%/90% (+KTL) Un-Biased 1.27E-01 1.28E-01 1.28E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01Ps90%/90% (-KTL) Un-Biased 1.20E-01 1.20E-01 1.21E-01 1.22E-01 1.22E-01 1.22E-01 1.22E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 327: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

327

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

3V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.160. Plot of Output Voltage Swing High IL= 2.5mA @ 3V #2 (V) versus total dose. The data showa significant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 328: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

328

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.160. Raw data for Output Voltage Swing High IL= 2.5mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.23E-01 1.24E-01 1.26E-01 1.27E-01 1.51E-01 1.33E-01 1.26E-01879 1.23E-01 1.20E-01 1.22E-01 1.23E-01 1.22E-01 1.21E-01 1.21E-01882 1.22E-01 1.23E-01 1.24E-01 1.26E-01 1.77E-01 1.39E-01 1.25E-01883 1.25E-01 1.27E-01 1.28E-01 1.29E-01 2.14E-01 1.42E-01 1.28E-01885 1.23E-01 1.25E-01 1.27E-01 1.26E-01 1.29E-01 1.27E-01 1.26E-01886 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.23E-01 1.23E-01887 1.19E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.21E-01 1.21E-01891 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.21E-01 1.21E-01892 1.21E-01 1.22E-01 1.23E-01 1.23E-01 1.25E-01 1.24E-01 1.23E-01895 1.19E-01 1.19E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.20E-01896 1.24E-01 1.24E-01 1.23E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01

Biased StatisticsAverage Biased 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.59E-01 1.32E-01 1.25E-01Std Dev Biased 1.13E-03 2.24E-03 2.51E-03 2.24E-03 3.78E-02 8.42E-03 2.67E-03Ps90%/90% (+KTL) Biased 1.26E-01 1.30E-01 1.32E-01 1.32E-01 2.62E-01 1.55E-01 1.33E-01Ps90%/90% (-KTL) Biased 1.20E-01 1.18E-01 1.18E-01 1.20E-01 5.49E-02 1.09E-01 1.18E-01Un-Biased StatisticsAverage Un-Biased 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.22E-01 1.22E-01Std Dev Un-Biased 1.38E-03 1.42E-03 1.44E-03 1.38E-03 1.42E-03 1.40E-03 1.45E-03Ps90%/90% (+KTL) Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.27E-01 1.26E-01 1.26E-01Ps90%/90% (-KTL) Un-Biased 1.16E-01 1.17E-01 1.17E-01 1.18E-01 1.19E-01 1.18E-01 1.18E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 329: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

329

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-01

1.00E+00

1.50E+00

2.00E+00

2.50E+00

3.00E+00

3.50E+00

4.00E+00

4.50E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

3V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.161. Plot of Output Voltage Swing High IL= 2.5mA @ 3V #3 (V) versus total dose. The data showa significant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 330: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

330

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.161. Raw data for Output Voltage Swing High IL= 2.5mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.23E-01 1.24E-01 1.26E-01 1.27E-01 1.52E-01 1.33E-01 1.26E-01879 1.24E-01 1.20E-01 1.22E-01 1.23E-01 1.22E-01 1.21E-01 1.21E-01882 1.21E-01 1.23E-01 1.24E-01 1.25E-01 1.58E-01 1.33E-01 1.25E-01883 1.25E-01 1.26E-01 1.28E-01 1.29E-01 2.97E+00 1.50E-01 1.28E-01885 1.23E-01 1.25E-01 1.26E-01 1.26E-01 1.29E-01 1.27E-01 1.27E-01886 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.23E-01 1.23E-01887 1.19E-01 1.19E-01 1.20E-01 1.21E-01 1.22E-01 1.21E-01 1.21E-01891 1.19E-01 1.20E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01892 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01895 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.21E-01896 1.23E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01

Biased StatisticsAverage Biased 1.23E-01 1.24E-01 1.25E-01 1.26E-01 7.06E-01 1.33E-01 1.25E-01Std Dev Biased 1.26E-03 2.51E-03 2.28E-03 2.08E-03 1.26E+00 1.10E-02 2.77E-03Ps90%/90% (+KTL) Biased 1.27E-01 1.31E-01 1.32E-01 1.32E-01 4.17E+00 1.63E-01 1.33E-01Ps90%/90% (-KTL) Biased 1.20E-01 1.17E-01 1.19E-01 1.20E-01 ######## 1.03E-01 1.18E-01Un-Biased StatisticsAverage Un-Biased 1.20E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.22E-01 1.22E-01Std Dev Un-Biased 1.33E-03 1.37E-03 1.34E-03 1.42E-03 1.60E-03 1.42E-03 1.32E-03Ps90%/90% (+KTL) Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01Ps90%/90% (-KTL) Un-Biased 1.17E-01 1.17E-01 1.18E-01 1.18E-01 1.18E-01 1.18E-01 1.18E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 331: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

331

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

3V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.162. Plot of Output Voltage Swing High IL= 2.5mA @ 3V #4 (V) versus total dose. The data showa significant change with radiation, however it is not sufficient for any of the units-under-test to exceedspecification (including after application of the KTL statistics). The solid diamonds are the average of themeasured data points for the sample irradiated under electrical bias while the shaded diamonds are the averageof the measured data points for the units irradiated with all pins tied to ground. The black lines (solid and/ordashed) are the average of the data points after application of the KTL statistics on the sample irradiated underelectrical bias while the gray lines (solid and/or dashed) are the average of the data points after application ofthe KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre-and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or testplan.

Page 332: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

332

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.162. Raw data for Output Voltage Swing High IL= 2.5mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E-01 1.25E-01 1.27E-01 1.27E-01 1.60E-01 1.37E-01 1.26E-01879 1.24E-01 1.24E-01 1.26E-01 1.27E-01 1.26E-01 1.25E-01 1.25E-01882 1.22E-01 1.24E-01 1.25E-01 1.26E-01 1.65E-01 1.37E-01 1.25E-01883 1.26E-01 1.28E-01 1.29E-01 1.31E-01 1.34E-01 1.30E-01 1.30E-01885 1.25E-01 1.26E-01 1.28E-01 1.27E-01 1.29E-01 1.28E-01 1.28E-01886 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01887 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.25E-01891 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.25E-01 1.25E-01892 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01895 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.29E-01 1.28E-01 1.28E-01896 1.28E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.27E-01 1.28E-01

Biased StatisticsAverage Biased 1.24E-01 1.25E-01 1.27E-01 1.28E-01 1.43E-01 1.31E-01 1.27E-01Std Dev Biased 1.54E-03 1.58E-03 1.63E-03 1.78E-03 1.82E-02 5.31E-03 1.85E-03Ps90%/90% (+KTL) Biased 1.28E-01 1.30E-01 1.31E-01 1.32E-01 1.93E-01 1.46E-01 1.32E-01Ps90%/90% (-KTL) Biased 1.20E-01 1.21E-01 1.22E-01 1.23E-01 9.28E-02 1.17E-01 1.22E-01Un-Biased StatisticsAverage Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01Std Dev Un-Biased 1.42E-03 1.48E-03 1.46E-03 1.44E-03 1.48E-03 1.63E-03 1.34E-03Ps90%/90% (+KTL) Un-Biased 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01Ps90%/90% (-KTL) Un-Biased 1.20E-01 1.20E-01 1.21E-01 1.22E-01 1.22E-01 1.21E-01 1.22E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 333: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

333

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

3V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.163. Plot of Output Voltage Swing Low IL= 0mA @ 3V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 334: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

334

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.163. Raw data for Output Voltage Swing Low IL= 0mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.46E-02 1.47E-02 1.45E-02 1.43E-02 9.89E-03 1.04E-02 1.50E-02879 1.46E-02 1.51E-02 1.48E-02 1.45E-02 1.55E-02 1.52E-02 1.53E-02882 1.44E-02 1.46E-02 1.42E-02 1.39E-02 9.99E-03 1.04E-02 1.47E-02883 1.47E-02 1.51E-02 1.46E-02 1.45E-02 1.01E-02 1.06E-02 1.53E-02885 1.42E-02 1.43E-02 1.39E-02 1.44E-02 1.35E-02 1.40E-02 1.46E-02886 1.46E-02 1.46E-02 1.49E-02 1.50E-02 1.52E-02 1.51E-02 1.49E-02887 1.45E-02 1.46E-02 1.48E-02 1.50E-02 1.51E-02 1.50E-02 1.49E-02891 1.45E-02 1.46E-02 1.50E-02 1.52E-02 1.53E-02 1.51E-02 1.52E-02892 1.45E-02 1.48E-02 1.50E-02 1.51E-02 1.56E-02 1.52E-02 1.50E-02895 1.47E-02 1.48E-02 1.50E-02 1.50E-02 1.54E-02 1.52E-02 1.49E-02896 1.45E-02 1.44E-02 1.44E-02 1.46E-02 1.45E-02 1.45E-02 1.45E-02

Biased StatisticsAverage Biased 1.45E-02 1.47E-02 1.44E-02 1.43E-02 1.18E-02 1.21E-02 1.50E-02Std Dev Biased 2.24E-04 3.48E-04 3.62E-04 2.66E-04 2.55E-03 2.33E-03 3.09E-04Ps90%/90% (+KTL) Biased 1.51E-02 1.57E-02 1.54E-02 1.50E-02 1.88E-02 1.85E-02 1.58E-02Ps90%/90% (-KTL) Biased 1.39E-02 1.38E-02 1.34E-02 1.36E-02 4.79E-03 5.75E-03 1.41E-02Un-Biased StatisticsAverage Un-Biased 1.46E-02 1.47E-02 1.49E-02 1.51E-02 1.53E-02 1.51E-02 1.50E-02Std Dev Un-Biased 7.60E-05 8.91E-05 8.73E-05 7.80E-05 1.64E-04 6.46E-05 1.13E-04Ps90%/90% (+KTL) Un-Biased 1.48E-02 1.49E-02 1.52E-02 1.53E-02 1.58E-02 1.53E-02 1.53E-02Ps90%/90% (-KTL) Un-Biased 1.44E-02 1.44E-02 1.47E-02 1.48E-02 1.49E-02 1.49E-02 1.47E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 335: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

335

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

3V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.164. Plot of Output Voltage Swing Low IL= 0mA @ 3V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 336: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

336

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.164. Raw data for Output Voltage Swing Low IL= 0mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.46E-02 1.48E-02 1.45E-02 1.43E-02 1.03E-02 1.10E-02 1.48E-02879 1.48E-02 1.52E-02 1.46E-02 1.44E-02 1.55E-02 1.53E-02 1.52E-02882 1.45E-02 1.46E-02 1.43E-02 1.34E-02 1.02E-02 1.05E-02 1.45E-02883 1.52E-02 1.53E-02 1.49E-02 1.47E-02 1.00E-02 1.04E-02 1.57E-02885 1.52E-02 1.53E-02 1.48E-02 1.55E-02 1.36E-02 1.47E-02 1.57E-02886 1.48E-02 1.50E-02 1.52E-02 1.51E-02 1.55E-02 1.54E-02 1.52E-02887 1.48E-02 1.50E-02 1.51E-02 1.55E-02 1.57E-02 1.54E-02 1.53E-02891 1.49E-02 1.50E-02 1.52E-02 1.52E-02 1.55E-02 1.54E-02 1.53E-02892 1.52E-02 1.53E-02 1.56E-02 1.57E-02 1.59E-02 1.58E-02 1.57E-02895 1.50E-02 1.52E-02 1.52E-02 1.54E-02 1.58E-02 1.56E-02 1.54E-02896 1.46E-02 1.46E-02 1.46E-02 1.48E-02 1.48E-02 1.46E-02 1.47E-02

Biased StatisticsAverage Biased 1.49E-02 1.51E-02 1.46E-02 1.45E-02 1.19E-02 1.24E-02 1.52E-02Std Dev Biased 2.96E-04 3.20E-04 2.50E-04 7.52E-04 2.48E-03 2.43E-03 5.27E-04Ps90%/90% (+KTL) Biased 1.57E-02 1.59E-02 1.53E-02 1.65E-02 1.87E-02 1.90E-02 1.66E-02Ps90%/90% (-KTL) Biased 1.40E-02 1.42E-02 1.39E-02 1.24E-02 5.13E-03 5.69E-03 1.37E-02Un-Biased StatisticsAverage Un-Biased 1.50E-02 1.51E-02 1.53E-02 1.54E-02 1.57E-02 1.55E-02 1.54E-02Std Dev Un-Biased 1.68E-04 1.37E-04 2.15E-04 2.07E-04 1.76E-04 1.87E-04 1.85E-04Ps90%/90% (+KTL) Un-Biased 1.54E-02 1.55E-02 1.58E-02 1.59E-02 1.62E-02 1.60E-02 1.59E-02Ps90%/90% (-KTL) Un-Biased 1.45E-02 1.47E-02 1.47E-02 1.48E-02 1.52E-02 1.50E-02 1.49E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 337: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

337

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

3V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.165. Plot of Output Voltage Swing Low IL= 0mA @ 3V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 338: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

338

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.165. Raw data for Output Voltage Swing Low IL= 0mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.45E-02 1.47E-02 1.43E-02 1.42E-02 1.03E-02 1.08E-02 1.48E-02879 1.44E-02 1.46E-02 1.41E-02 1.40E-02 1.52E-02 1.51E-02 1.49E-02882 1.43E-02 1.46E-02 1.41E-02 1.39E-02 9.99E-03 1.04E-02 1.46E-02883 1.48E-02 1.49E-02 1.44E-02 1.42E-02 9.62E-03 9.99E-03 1.49E-02885 1.50E-02 1.51E-02 1.44E-02 1.53E-02 1.35E-02 1.46E-02 1.53E-02886 1.45E-02 1.46E-02 1.48E-02 1.51E-02 1.53E-02 1.51E-02 1.49E-02887 1.47E-02 1.49E-02 1.50E-02 1.51E-02 1.54E-02 1.53E-02 1.52E-02891 1.47E-02 1.48E-02 1.50E-02 1.51E-02 1.53E-02 1.52E-02 1.51E-02892 1.48E-02 1.50E-02 1.52E-02 1.52E-02 1.56E-02 1.55E-02 1.52E-02895 1.46E-02 1.48E-02 1.51E-02 1.51E-02 1.54E-02 1.52E-02 1.52E-02896 1.43E-02 1.44E-02 1.44E-02 1.43E-02 1.43E-02 1.42E-02 1.44E-02

Biased StatisticsAverage Biased 1.46E-02 1.48E-02 1.43E-02 1.43E-02 1.17E-02 1.22E-02 1.49E-02Std Dev Biased 2.80E-04 2.11E-04 1.77E-04 5.60E-04 2.48E-03 2.45E-03 2.38E-04Ps90%/90% (+KTL) Biased 1.54E-02 1.53E-02 1.48E-02 1.59E-02 1.85E-02 1.89E-02 1.55E-02Ps90%/90% (-KTL) Biased 1.38E-02 1.42E-02 1.38E-02 1.28E-02 4.90E-03 5.45E-03 1.42E-02Un-Biased StatisticsAverage Un-Biased 1.47E-02 1.48E-02 1.50E-02 1.51E-02 1.54E-02 1.53E-02 1.51E-02Std Dev Un-Biased 1.00E-04 1.55E-04 1.43E-04 5.22E-05 1.33E-04 1.56E-04 1.07E-04Ps90%/90% (+KTL) Un-Biased 1.49E-02 1.52E-02 1.54E-02 1.52E-02 1.58E-02 1.57E-02 1.54E-02Ps90%/90% (-KTL) Un-Biased 1.44E-02 1.44E-02 1.46E-02 1.49E-02 1.50E-02 1.48E-02 1.48E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 339: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

339

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

3V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.166. Plot of Output Voltage Swing Low IL= 0mA @ 3V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 340: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

340

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.166. Raw data for Output Voltage Swing Low IL= 0mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 1.49E-02 1.50E-02 1.47E-02 1.44E-02 1.01E-02 1.08E-02 1.51E-02879 1.50E-02 1.57E-02 1.53E-02 1.50E-02 1.60E-02 1.57E-02 1.57E-02882 1.49E-02 1.50E-02 1.46E-02 1.44E-02 1.03E-02 1.05E-02 1.53E-02883 1.50E-02 1.52E-02 1.48E-02 1.48E-02 1.21E-02 1.44E-02 1.55E-02885 1.44E-02 1.46E-02 1.44E-02 1.49E-02 1.39E-02 1.45E-02 1.49E-02886 1.49E-02 1.51E-02 1.53E-02 1.53E-02 1.56E-02 1.55E-02 1.54E-02887 1.50E-02 1.51E-02 1.52E-02 1.53E-02 1.58E-02 1.54E-02 1.53E-02891 1.48E-02 1.52E-02 1.51E-02 1.54E-02 1.56E-02 1.54E-02 1.52E-02892 1.49E-02 1.52E-02 1.52E-02 1.53E-02 1.58E-02 1.55E-02 1.54E-02895 1.49E-02 1.52E-02 1.53E-02 1.54E-02 1.57E-02 1.56E-02 1.54E-02896 1.48E-02 1.49E-02 1.48E-02 1.49E-02 1.50E-02 1.47E-02 1.49E-02

Biased StatisticsAverage Biased 1.48E-02 1.51E-02 1.48E-02 1.47E-02 1.25E-02 1.32E-02 1.53E-02Std Dev Biased 2.57E-04 3.81E-04 3.30E-04 2.81E-04 2.50E-03 2.38E-03 3.17E-04Ps90%/90% (+KTL) Biased 1.55E-02 1.61E-02 1.57E-02 1.54E-02 1.93E-02 1.97E-02 1.61E-02Ps90%/90% (-KTL) Biased 1.41E-02 1.40E-02 1.38E-02 1.39E-02 5.61E-03 6.64E-03 1.44E-02Un-Biased StatisticsAverage Un-Biased 1.49E-02 1.51E-02 1.52E-02 1.53E-02 1.57E-02 1.55E-02 1.53E-02Std Dev Un-Biased 8.00E-05 3.21E-05 7.70E-05 5.15E-05 1.01E-04 6.73E-05 1.09E-04Ps90%/90% (+KTL) Un-Biased 1.51E-02 1.52E-02 1.54E-02 1.55E-02 1.60E-02 1.57E-02 1.56E-02Ps90%/90% (-KTL) Un-Biased 1.47E-02 1.51E-02 1.50E-02 1.52E-02 1.54E-02 1.53E-02 1.50E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 341: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

341

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

3V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.167. Plot of Output Voltage Swing Low IL= 1mA @ 3V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 342: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

342

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.167. Raw data for Output Voltage Swing Low IL= 1mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.04E-02 4.07E-02 4.05E-02 4.06E-02 3.77E-02 3.80E-02 4.12E-02879 4.05E-02 4.08E-02 4.07E-02 4.05E-02 4.12E-02 4.08E-02 4.11E-02882 3.98E-02 4.01E-02 4.01E-02 4.00E-02 3.71E-02 3.75E-02 4.05E-02883 4.07E-02 4.10E-02 4.10E-02 4.09E-02 3.80E-02 3.84E-02 4.18E-02885 3.96E-02 4.00E-02 3.98E-02 4.00E-02 3.98E-02 4.00E-02 4.05E-02886 4.01E-02 4.03E-02 4.04E-02 4.08E-02 4.09E-02 4.06E-02 4.05E-02887 4.01E-02 4.03E-02 4.05E-02 4.07E-02 4.08E-02 4.07E-02 4.05E-02891 4.01E-02 4.02E-02 4.04E-02 4.06E-02 4.09E-02 4.07E-02 4.06E-02892 4.03E-02 4.03E-02 4.05E-02 4.08E-02 4.13E-02 4.09E-02 4.07E-02895 4.04E-02 4.05E-02 4.06E-02 4.07E-02 4.14E-02 4.08E-02 4.07E-02896 3.98E-02 3.97E-02 3.96E-02 3.98E-02 3.98E-02 3.98E-02 3.96E-02

Biased StatisticsAverage Biased 4.02E-02 4.05E-02 4.04E-02 4.04E-02 3.88E-02 3.89E-02 4.10E-02Std Dev Biased 4.68E-04 4.47E-04 4.69E-04 3.94E-04 1.69E-03 1.42E-03 5.38E-04Ps90%/90% (+KTL) Biased 4.15E-02 4.17E-02 4.17E-02 4.15E-02 4.34E-02 4.28E-02 4.25E-02Ps90%/90% (-KTL) Biased 3.89E-02 3.93E-02 3.91E-02 3.93E-02 3.41E-02 3.50E-02 3.95E-02Un-Biased StatisticsAverage Un-Biased 4.02E-02 4.03E-02 4.05E-02 4.07E-02 4.10E-02 4.07E-02 4.06E-02Std Dev Un-Biased 1.41E-04 1.08E-04 1.03E-04 7.40E-05 2.67E-04 1.11E-04 1.14E-04Ps90%/90% (+KTL) Un-Biased 4.06E-02 4.06E-02 4.08E-02 4.09E-02 4.18E-02 4.10E-02 4.09E-02Ps90%/90% (-KTL) Un-Biased 3.98E-02 4.00E-02 4.02E-02 4.05E-02 4.03E-02 4.04E-02 4.03E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 343: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

343

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

3V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.168. Plot of Output Voltage Swing Low IL= 1mA @ 3V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 344: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

344

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.168. Raw data for Output Voltage Swing Low IL= 1mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.04E-02 4.05E-02 4.04E-02 4.05E-02 3.78E-02 3.82E-02 4.08E-02879 4.04E-02 4.08E-02 4.05E-02 4.07E-02 4.12E-02 4.09E-02 4.10E-02882 4.00E-02 4.02E-02 4.01E-02 3.95E-02 3.74E-02 3.75E-02 4.04E-02883 4.08E-02 4.13E-02 4.12E-02 4.12E-02 3.80E-02 3.85E-02 4.19E-02885 4.08E-02 4.11E-02 4.10E-02 4.15E-02 4.04E-02 4.10E-02 4.18E-02886 4.04E-02 4.07E-02 4.07E-02 4.11E-02 4.13E-02 4.09E-02 4.09E-02887 4.04E-02 4.06E-02 4.08E-02 4.09E-02 4.14E-02 4.10E-02 4.09E-02891 4.01E-02 4.03E-02 4.05E-02 4.06E-02 4.09E-02 4.08E-02 4.06E-02892 4.09E-02 4.11E-02 4.14E-02 4.17E-02 4.20E-02 4.18E-02 4.16E-02895 4.01E-02 4.03E-02 4.05E-02 4.06E-02 4.10E-02 4.07E-02 4.05E-02896 4.01E-02 4.01E-02 4.01E-02 4.02E-02 4.03E-02 4.01E-02 4.02E-02

Biased StatisticsAverage Biased 4.04E-02 4.08E-02 4.06E-02 4.07E-02 3.90E-02 3.92E-02 4.12E-02Std Dev Biased 3.54E-04 4.50E-04 4.49E-04 7.58E-04 1.71E-03 1.64E-03 6.71E-04Ps90%/90% (+KTL) Biased 4.14E-02 4.20E-02 4.18E-02 4.28E-02 4.36E-02 4.37E-02 4.30E-02Ps90%/90% (-KTL) Biased 3.95E-02 3.95E-02 3.94E-02 3.86E-02 3.43E-02 3.47E-02 3.93E-02Un-Biased StatisticsAverage Un-Biased 4.04E-02 4.06E-02 4.08E-02 4.09E-02 4.13E-02 4.10E-02 4.09E-02Std Dev Un-Biased 3.20E-04 3.36E-04 3.68E-04 4.58E-04 4.54E-04 4.42E-04 4.27E-04Ps90%/90% (+KTL) Un-Biased 4.13E-02 4.15E-02 4.18E-02 4.22E-02 4.26E-02 4.22E-02 4.21E-02Ps90%/90% (-KTL) Un-Biased 3.95E-02 3.97E-02 3.98E-02 3.97E-02 4.01E-02 3.98E-02 3.97E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 345: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

345

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

3V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.169. Plot of Output Voltage Swing Low IL= 1mA @ 3V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 346: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

346

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.169. Raw data for Output Voltage Swing Low IL= 1mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.00E-02 4.02E-02 4.01E-02 4.02E-02 3.74E-02 3.79E-02 4.05E-02879 4.02E-02 4.00E-02 3.99E-02 4.00E-02 4.07E-02 4.04E-02 4.04E-02882 3.96E-02 3.98E-02 3.97E-02 3.97E-02 3.72E-02 3.73E-02 4.02E-02883 4.02E-02 4.06E-02 4.06E-02 4.05E-02 3.74E-02 3.76E-02 4.09E-02885 4.05E-02 4.08E-02 4.07E-02 4.10E-02 4.01E-02 4.08E-02 4.13E-02886 4.02E-02 4.02E-02 4.05E-02 4.05E-02 4.10E-02 4.07E-02 4.07E-02887 4.00E-02 4.02E-02 4.03E-02 4.06E-02 4.09E-02 4.08E-02 4.06E-02891 3.97E-02 3.99E-02 4.01E-02 4.03E-02 4.06E-02 4.04E-02 4.02E-02892 4.05E-02 4.08E-02 4.08E-02 4.13E-02 4.15E-02 4.13E-02 4.10E-02895 3.98E-02 3.98E-02 4.01E-02 4.02E-02 4.06E-02 4.05E-02 4.01E-02896 3.97E-02 3.96E-02 3.96E-02 3.98E-02 3.98E-02 3.97E-02 3.97E-02

Biased StatisticsAverage Biased 4.01E-02 4.03E-02 4.02E-02 4.03E-02 3.86E-02 3.88E-02 4.07E-02Std Dev Biased 3.45E-04 3.99E-04 4.58E-04 5.23E-04 1.71E-03 1.66E-03 4.43E-04Ps90%/90% (+KTL) Biased 4.10E-02 4.14E-02 4.15E-02 4.17E-02 4.32E-02 4.33E-02 4.19E-02Ps90%/90% (-KTL) Biased 3.91E-02 3.92E-02 3.89E-02 3.88E-02 3.39E-02 3.43E-02 3.94E-02Un-Biased StatisticsAverage Un-Biased 4.01E-02 4.02E-02 4.03E-02 4.06E-02 4.09E-02 4.07E-02 4.05E-02Std Dev Un-Biased 3.28E-04 3.84E-04 2.98E-04 4.17E-04 3.55E-04 3.63E-04 3.90E-04Ps90%/90% (+KTL) Un-Biased 4.10E-02 4.12E-02 4.12E-02 4.17E-02 4.19E-02 4.17E-02 4.16E-02Ps90%/90% (-KTL) Un-Biased 3.92E-02 3.91E-02 3.95E-02 3.94E-02 3.99E-02 3.97E-02 3.94E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 347: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

347

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

3V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.170. Plot of Output Voltage Swing Low IL= 1mA @ 3V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 348: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

348

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.170. Raw data for Output Voltage Swing Low IL= 1mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.05E-02 4.09E-02 4.06E-02 4.06E-02 3.80E-02 3.83E-02 4.12E-02879 4.07E-02 4.14E-02 4.11E-02 4.12E-02 4.18E-02 4.15E-02 4.15E-02882 4.04E-02 4.05E-02 4.04E-02 4.05E-02 3.77E-02 3.80E-02 4.10E-02883 4.09E-02 4.13E-02 4.14E-02 4.13E-02 3.97E-02 4.09E-02 4.21E-02885 4.02E-02 4.04E-02 4.03E-02 4.07E-02 4.02E-02 4.06E-02 4.09E-02886 4.06E-02 4.07E-02 4.09E-02 4.12E-02 4.13E-02 4.12E-02 4.11E-02887 4.05E-02 4.06E-02 4.09E-02 4.11E-02 4.12E-02 4.11E-02 4.09E-02891 4.08E-02 4.08E-02 4.09E-02 4.14E-02 4.15E-02 4.11E-02 4.12E-02892 4.06E-02 4.08E-02 4.11E-02 4.13E-02 4.18E-02 4.14E-02 4.13E-02895 4.08E-02 4.11E-02 4.13E-02 4.13E-02 4.18E-02 4.15E-02 4.14E-02896 4.03E-02 4.04E-02 4.03E-02 4.03E-02 4.03E-02 4.02E-02 4.02E-02

Biased StatisticsAverage Biased 4.05E-02 4.09E-02 4.08E-02 4.09E-02 3.95E-02 3.99E-02 4.14E-02Std Dev Biased 2.48E-04 4.39E-04 4.75E-04 3.50E-04 1.70E-03 1.60E-03 4.73E-04Ps90%/90% (+KTL) Biased 4.12E-02 4.21E-02 4.21E-02 4.18E-02 4.41E-02 4.42E-02 4.27E-02Ps90%/90% (-KTL) Biased 3.99E-02 3.97E-02 3.95E-02 3.99E-02 3.48E-02 3.55E-02 4.01E-02Un-Biased StatisticsAverage Un-Biased 4.06E-02 4.08E-02 4.10E-02 4.13E-02 4.15E-02 4.13E-02 4.12E-02Std Dev Un-Biased 1.12E-04 1.79E-04 1.74E-04 1.35E-04 2.63E-04 1.81E-04 2.20E-04Ps90%/90% (+KTL) Un-Biased 4.10E-02 4.13E-02 4.15E-02 4.16E-02 4.22E-02 4.18E-02 4.18E-02Ps90%/90% (-KTL) Un-Biased 4.03E-02 4.03E-02 4.05E-02 4.09E-02 4.08E-02 4.08E-02 4.06E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 349: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

349

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 3

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.171. Plot of Output Voltage Swing Low IL= 2.5mA @ 3V #1 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 350: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

350

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.171. Raw data for Output Voltage Swing Low IL= 2.5mA @ 3V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 3V #1 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.84E-02 7.86E-02 7.87E-02 7.88E-02 7.67E-02 7.70E-02 7.95E-02879 7.83E-02 7.79E-02 7.82E-02 7.84E-02 7.87E-02 7.81E-02 7.86E-02882 7.72E-02 7.77E-02 7.77E-02 7.73E-02 7.57E-02 7.53E-02 7.82E-02883 7.84E-02 7.89E-02 7.89E-02 7.91E-02 7.68E-02 7.70E-02 7.95E-02885 7.72E-02 7.74E-02 7.74E-02 7.77E-02 7.79E-02 7.77E-02 7.82E-02886 7.79E-02 7.79E-02 7.82E-02 7.82E-02 7.88E-02 7.82E-02 7.84E-02887 7.77E-02 7.76E-02 7.82E-02 7.84E-02 7.85E-02 7.85E-02 7.81E-02891 7.74E-02 7.77E-02 7.71E-02 7.79E-02 7.80E-02 7.77E-02 7.78E-02892 7.76E-02 7.80E-02 7.76E-02 7.84E-02 7.86E-02 7.84E-02 7.80E-02895 7.82E-02 7.81E-02 7.84E-02 7.83E-02 7.89E-02 7.86E-02 7.86E-02896 7.73E-02 7.70E-02 7.72E-02 7.72E-02 7.75E-02 7.70E-02 7.76E-02

Biased StatisticsAverage Biased 7.79E-02 7.81E-02 7.82E-02 7.82E-02 7.72E-02 7.70E-02 7.88E-02Std Dev Biased 6.50E-04 6.30E-04 6.59E-04 7.43E-04 1.16E-03 1.08E-03 6.58E-04Ps90%/90% (+KTL) Biased 7.97E-02 7.98E-02 8.00E-02 8.03E-02 8.03E-02 8.00E-02 8.06E-02Ps90%/90% (-KTL) Biased 7.61E-02 7.64E-02 7.64E-02 7.62E-02 7.40E-02 7.41E-02 7.70E-02Un-Biased StatisticsAverage Un-Biased 7.78E-02 7.79E-02 7.79E-02 7.82E-02 7.86E-02 7.83E-02 7.82E-02Std Dev Un-Biased 3.17E-04 2.12E-04 5.23E-04 1.99E-04 3.40E-04 3.63E-04 3.44E-04Ps90%/90% (+KTL) Un-Biased 7.86E-02 7.84E-02 7.93E-02 7.88E-02 7.95E-02 7.93E-02 7.91E-02Ps90%/90% (-KTL) Un-Biased 7.69E-02 7.73E-02 7.65E-02 7.77E-02 7.76E-02 7.73E-02 7.72E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 351: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

351

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 3

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.172. Plot of Output Voltage Swing Low IL= 2.5mA @ 3V #2 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 352: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

352

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.172. Raw data for Output Voltage Swing Low IL= 2.5mA @ 3V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 3V #2 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.84E-02 7.87E-02 7.90E-02 7.92E-02 7.67E-02 7.70E-02 7.92E-02879 7.85E-02 7.81E-02 7.82E-02 7.76E-02 7.88E-02 7.83E-02 7.85E-02882 7.77E-02 7.82E-02 7.80E-02 7.79E-02 7.60E-02 7.61E-02 7.85E-02883 7.82E-02 7.86E-02 7.92E-02 7.90E-02 7.67E-02 7.71E-02 7.95E-02885 7.82E-02 7.86E-02 7.86E-02 7.93E-02 7.84E-02 7.87E-02 7.93E-02886 7.81E-02 7.86E-02 7.87E-02 7.86E-02 7.92E-02 7.89E-02 7.90E-02887 7.76E-02 7.74E-02 7.81E-02 7.82E-02 7.84E-02 7.83E-02 7.79E-02891 7.77E-02 7.79E-02 7.77E-02 7.79E-02 7.86E-02 7.82E-02 7.83E-02892 7.86E-02 7.87E-02 7.93E-02 7.94E-02 7.98E-02 7.96E-02 7.89E-02895 7.76E-02 7.77E-02 7.76E-02 7.81E-02 7.86E-02 7.80E-02 7.79E-02896 7.79E-02 7.76E-02 7.77E-02 7.77E-02 7.78E-02 7.78E-02 7.79E-02

Biased StatisticsAverage Biased 7.82E-02 7.84E-02 7.86E-02 7.86E-02 7.73E-02 7.74E-02 7.90E-02Std Dev Biased 3.10E-04 2.72E-04 5.37E-04 7.82E-04 1.21E-03 1.04E-03 4.58E-04Ps90%/90% (+KTL) Biased 7.91E-02 7.92E-02 8.01E-02 8.07E-02 8.06E-02 8.03E-02 8.02E-02Ps90%/90% (-KTL) Biased 7.74E-02 7.77E-02 7.71E-02 7.64E-02 7.40E-02 7.46E-02 7.77E-02Un-Biased StatisticsAverage Un-Biased 7.79E-02 7.81E-02 7.83E-02 7.84E-02 7.89E-02 7.86E-02 7.84E-02Std Dev Un-Biased 4.58E-04 5.72E-04 7.29E-04 5.69E-04 5.94E-04 6.23E-04 5.19E-04Ps90%/90% (+KTL) Un-Biased 7.92E-02 7.96E-02 8.03E-02 8.00E-02 8.05E-02 8.03E-02 7.98E-02Ps90%/90% (-KTL) Un-Biased 7.66E-02 7.65E-02 7.63E-02 7.69E-02 7.73E-02 7.69E-02 7.70E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 353: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

353

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 3

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.173. Plot of Output Voltage Swing Low IL= 2.5mA @ 3V #3 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 354: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

354

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.173. Raw data for Output Voltage Swing Low IL= 2.5mA @ 3V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 3V #3 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.76E-02 7.82E-02 7.81E-02 7.83E-02 7.62E-02 7.67E-02 7.87E-02879 7.80E-02 7.66E-02 7.69E-02 7.69E-02 7.75E-02 7.71E-02 7.72E-02882 7.72E-02 7.75E-02 7.72E-02 7.78E-02 7.55E-02 7.59E-02 7.82E-02883 7.73E-02 7.80E-02 7.75E-02 7.79E-02 7.62E-02 7.59E-02 7.87E-02885 7.75E-02 7.81E-02 7.80E-02 7.85E-02 7.84E-02 7.82E-02 7.90E-02886 7.79E-02 7.82E-02 7.78E-02 7.85E-02 7.87E-02 7.80E-02 7.81E-02887 7.70E-02 7.69E-02 7.73E-02 7.78E-02 7.80E-02 7.77E-02 7.74E-02891 7.69E-02 7.74E-02 7.74E-02 7.75E-02 7.80E-02 7.76E-02 7.73E-02892 7.73E-02 7.80E-02 7.79E-02 7.85E-02 7.87E-02 7.85E-02 7.82E-02895 7.68E-02 7.70E-02 7.75E-02 7.73E-02 7.76E-02 7.75E-02 7.75E-02896 7.71E-02 7.69E-02 7.72E-02 7.73E-02 7.71E-02 7.71E-02 7.74E-02

Biased StatisticsAverage Biased 7.75E-02 7.77E-02 7.75E-02 7.79E-02 7.67E-02 7.67E-02 7.83E-02Std Dev Biased 2.83E-04 6.43E-04 5.20E-04 6.15E-04 1.15E-03 9.66E-04 7.09E-04Ps90%/90% (+KTL) Biased 7.83E-02 7.94E-02 7.89E-02 7.96E-02 7.99E-02 7.94E-02 8.03E-02Ps90%/90% (-KTL) Biased 7.67E-02 7.59E-02 7.61E-02 7.62E-02 7.36E-02 7.41E-02 7.64E-02Un-Biased StatisticsAverage Un-Biased 7.72E-02 7.75E-02 7.76E-02 7.79E-02 7.82E-02 7.78E-02 7.77E-02Std Dev Un-Biased 4.29E-04 5.81E-04 2.72E-04 5.35E-04 4.88E-04 4.33E-04 4.31E-04Ps90%/90% (+KTL) Un-Biased 7.84E-02 7.91E-02 7.83E-02 7.94E-02 7.95E-02 7.90E-02 7.89E-02Ps90%/90% (-KTL) Un-Biased 7.60E-02 7.59E-02 7.68E-02 7.64E-02 7.69E-02 7.67E-02 7.65E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 355: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

355

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 3

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.174. Plot of Output Voltage Swing Low IL= 2.5mA @ 3V #4 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 356: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

356

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.174. Raw data for Output Voltage Swing Low IL= 2.5mA @ 3V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 3V #4 (V)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 7.86E-02 7.89E-02 7.90E-02 7.93E-02 7.68E-02 7.71E-02 7.95E-02879 7.85E-02 7.91E-02 7.91E-02 7.90E-02 7.97E-02 7.92E-02 7.94E-02882 7.79E-02 7.86E-02 7.87E-02 7.86E-02 7.64E-02 7.63E-02 7.88E-02883 7.87E-02 7.94E-02 7.95E-02 7.94E-02 7.83E-02 7.94E-02 7.97E-02885 7.78E-02 7.84E-02 7.80E-02 7.87E-02 7.84E-02 7.84E-02 7.90E-02886 7.83E-02 7.85E-02 7.86E-02 7.89E-02 7.91E-02 7.89E-02 7.90E-02887 7.82E-02 7.88E-02 7.88E-02 7.90E-02 7.96E-02 7.89E-02 7.91E-02891 7.83E-02 7.85E-02 7.89E-02 7.92E-02 7.93E-02 7.91E-02 7.90E-02892 7.81E-02 7.84E-02 7.91E-02 7.91E-02 7.96E-02 7.92E-02 7.92E-02895 7.87E-02 7.91E-02 7.94E-02 7.95E-02 7.98E-02 7.95E-02 7.91E-02896 7.78E-02 7.82E-02 7.85E-02 7.82E-02 7.82E-02 7.80E-02 7.82E-02

Biased StatisticsAverage Biased 7.83E-02 7.89E-02 7.89E-02 7.90E-02 7.79E-02 7.81E-02 7.93E-02Std Dev Biased 4.19E-04 4.12E-04 5.71E-04 3.51E-04 1.33E-03 1.34E-03 3.82E-04Ps90%/90% (+KTL) Biased 7.94E-02 8.00E-02 8.04E-02 7.99E-02 8.16E-02 8.17E-02 8.03E-02Ps90%/90% (-KTL) Biased 7.71E-02 7.77E-02 7.73E-02 7.80E-02 7.42E-02 7.44E-02 7.82E-02Un-Biased StatisticsAverage Un-Biased 7.83E-02 7.86E-02 7.90E-02 7.91E-02 7.95E-02 7.91E-02 7.91E-02Std Dev Un-Biased 2.13E-04 2.87E-04 3.21E-04 2.40E-04 2.76E-04 2.42E-04 5.86E-05Ps90%/90% (+KTL) Un-Biased 7.89E-02 7.94E-02 7.98E-02 7.98E-02 8.02E-02 7.98E-02 7.92E-02Ps90%/90% (-KTL) Un-Biased 7.77E-02 7.79E-02 7.81E-02 7.85E-02 7.87E-02 7.84E-02 7.89E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 357: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

357

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

5.00E-03

1.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

3V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.175. Plot of Positive Short-Circuit Current @ 3V #1 (A) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 358: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

358

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.175. Raw data for Positive Short-Circuit Current @ 3V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 3V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.03E-02 -2.00E-02 -1.95E-02 -1.92E-02 -7.12E-03 -1.40E-02 -1.96E-02879 -2.03E-02 -1.99E-02 -1.94E-02 -1.90E-02 -1.95E-02 -1.96E-02 -1.98E-02882 -2.07E-02 -2.04E-02 -1.99E-02 -1.94E-02 -5.66E-03 -1.26E-02 -1.99E-02883 -1.95E-02 -1.90E-02 -1.86E-02 -1.83E-02 -6.07E-03 -1.28E-02 -1.87E-02885 -2.00E-02 -1.97E-02 -1.92E-02 -1.95E-02 -1.85E-02 -1.90E-02 -1.94E-02886 -2.06E-02 -2.05E-02 -2.03E-02 -2.02E-02 -2.00E-02 -2.00E-02 -2.02E-02887 -2.02E-02 -2.00E-02 -1.99E-02 -1.97E-02 -1.95E-02 -1.95E-02 -1.98E-02891 -2.02E-02 -2.00E-02 -1.99E-02 -1.97E-02 -1.95E-02 -1.95E-02 -1.98E-02892 -2.05E-02 -2.03E-02 -2.01E-02 -1.99E-02 -1.96E-02 -1.96E-02 -2.00E-02895 -1.96E-02 -1.95E-02 -1.93E-02 -1.92E-02 -1.89E-02 -1.89E-02 -1.92E-02896 -1.91E-02 -1.91E-02 -1.91E-02 -1.91E-02 -1.91E-02 -1.91E-02 -1.91E-02

Biased StatisticsAverage Biased -2.02E-02 -1.98E-02 -1.93E-02 -1.91E-02 -1.14E-02 -1.56E-02 -1.95E-02Std Dev Biased 4.66E-04 4.88E-04 4.71E-04 4.92E-04 6.99E-03 3.44E-03 4.94E-04Ps90%/90% (+KTL) Biased -1.89E-02 -1.85E-02 -1.80E-02 -1.77E-02 7.80E-03 -6.15E-03 -1.81E-02Ps90%/90% (-KTL) Biased -2.14E-02 -2.11E-02 -2.06E-02 -2.04E-02 -3.05E-02 -2.50E-02 -2.08E-02Un-Biased StatisticsAverage Un-Biased -2.02E-02 -2.00E-02 -1.99E-02 -1.97E-02 -1.95E-02 -1.95E-02 -1.98E-02Std Dev Un-Biased 3.84E-04 3.77E-04 3.78E-04 3.77E-04 3.84E-04 3.74E-04 3.71E-04Ps90%/90% (+KTL) Un-Biased -1.92E-02 -1.90E-02 -1.88E-02 -1.87E-02 -1.84E-02 -1.85E-02 -1.88E-02Ps90%/90% (-KTL) Un-Biased -2.13E-02 -2.11E-02 -2.09E-02 -2.08E-02 -2.05E-02 -2.05E-02 -2.08E-02Specification MAX -1.20E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS FAIL FAIL PASS

Total Dose (krad(Si))

Page 359: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

359

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

5.00E-03

1.00E-02

1.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

3V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.176. Plot of Positive Short-Circuit Current @ 3V #2 (A) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 360: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

360

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.176. Raw data for Positive Short-Circuit Current @ 3V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 3V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.05E-02 -2.02E-02 -1.98E-02 -1.95E-02 -9.36E-03 -1.54E-02 -1.98E-02879 -2.05E-02 -2.09E-02 -2.02E-02 -1.96E-02 -2.02E-02 -2.04E-02 -2.07E-02882 -2.09E-02 -2.06E-02 -2.01E-02 -1.95E-02 -5.12E-03 -1.28E-02 -2.00E-02883 -1.97E-02 -1.92E-02 -1.87E-02 -1.83E-02 -3.39E-03 -1.14E-02 -1.87E-02885 -2.04E-02 -2.00E-02 -1.94E-02 -1.98E-02 -1.79E-02 -1.89E-02 -1.95E-02886 -2.09E-02 -2.07E-02 -2.06E-02 -2.04E-02 -2.02E-02 -2.02E-02 -2.05E-02887 -2.13E-02 -2.11E-02 -2.08E-02 -2.06E-02 -2.03E-02 -2.02E-02 -2.08E-02891 -2.15E-02 -2.13E-02 -2.12E-02 -2.10E-02 -2.08E-02 -2.08E-02 -2.11E-02892 -2.06E-02 -2.04E-02 -2.02E-02 -2.00E-02 -1.97E-02 -1.97E-02 -2.01E-02895 -2.18E-02 -2.16E-02 -2.15E-02 -2.13E-02 -2.10E-02 -2.11E-02 -2.14E-02896 -2.02E-02 -2.02E-02 -2.02E-02 -2.02E-02 -2.02E-02 -2.02E-02 -2.02E-02

Biased StatisticsAverage Biased -2.04E-02 -2.02E-02 -1.96E-02 -1.93E-02 -1.12E-02 -1.58E-02 -1.97E-02Std Dev Biased 4.49E-04 6.41E-04 6.25E-04 5.79E-04 7.56E-03 3.88E-03 7.15E-04Ps90%/90% (+KTL) Biased -1.92E-02 -1.84E-02 -1.79E-02 -1.77E-02 9.51E-03 -5.13E-03 -1.78E-02Ps90%/90% (-KTL) Biased -2.16E-02 -2.19E-02 -2.13E-02 -2.09E-02 -3.19E-02 -2.64E-02 -2.17E-02Un-Biased StatisticsAverage Un-Biased -2.12E-02 -2.10E-02 -2.08E-02 -2.07E-02 -2.04E-02 -2.04E-02 -2.07E-02Std Dev Un-Biased 4.60E-04 4.72E-04 4.81E-04 4.91E-04 5.11E-04 5.27E-04 4.89E-04Ps90%/90% (+KTL) Un-Biased -1.99E-02 -1.97E-02 -1.95E-02 -1.93E-02 -1.90E-02 -1.89E-02 -1.94E-02Ps90%/90% (-KTL) Un-Biased -2.25E-02 -2.23E-02 -2.22E-02 -2.20E-02 -2.18E-02 -2.18E-02 -2.21E-02Specification MAX -1.20E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS FAIL FAIL PASS

Total Dose (krad(Si))

Page 361: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

361

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

5.00E-03

1.00E-02

1.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

3V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.177. Plot of Positive Short-Circuit Current @ 3V #3 (A) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 362: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

362

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.177. Raw data for Positive Short-Circuit Current @ 3V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 3V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.05E-02 -2.02E-02 -1.98E-02 -1.95E-02 -9.17E-03 -1.56E-02 -1.98E-02879 -2.05E-02 -2.09E-02 -2.02E-02 -1.97E-02 -2.04E-02 -2.06E-02 -2.08E-02882 -2.10E-02 -2.07E-02 -2.03E-02 -2.00E-02 -7.59E-03 -1.50E-02 -2.03E-02883 -1.97E-02 -1.92E-02 -1.87E-02 -1.84E-02 -1.55E-03 -8.93E-03 -1.86E-02885 -2.02E-02 -1.98E-02 -1.92E-02 -1.96E-02 -1.79E-02 -1.88E-02 -1.94E-02886 -2.09E-02 -2.08E-02 -2.06E-02 -2.05E-02 -2.02E-02 -2.02E-02 -2.05E-02887 -2.13E-02 -2.11E-02 -2.09E-02 -2.07E-02 -2.03E-02 -2.03E-02 -2.08E-02891 -2.17E-02 -2.15E-02 -2.14E-02 -2.12E-02 -2.10E-02 -2.10E-02 -2.13E-02892 -2.05E-02 -2.03E-02 -2.01E-02 -1.99E-02 -1.96E-02 -1.96E-02 -2.00E-02895 -2.15E-02 -2.14E-02 -2.12E-02 -2.11E-02 -2.08E-02 -2.08E-02 -2.11E-02896 -2.04E-02 -2.04E-02 -2.04E-02 -2.04E-02 -2.04E-02 -2.04E-02 -2.04E-02

Biased StatisticsAverage Biased -2.04E-02 -2.02E-02 -1.96E-02 -1.94E-02 -1.13E-02 -1.58E-02 -1.98E-02Std Dev Biased 4.77E-04 6.95E-04 6.91E-04 6.01E-04 7.73E-03 4.45E-03 8.58E-04Ps90%/90% (+KTL) Biased -1.91E-02 -1.83E-02 -1.78E-02 -1.78E-02 9.88E-03 -3.56E-03 -1.74E-02Ps90%/90% (-KTL) Biased -2.17E-02 -2.21E-02 -2.15E-02 -2.11E-02 -3.25E-02 -2.80E-02 -2.21E-02Un-Biased StatisticsAverage Un-Biased -2.12E-02 -2.10E-02 -2.08E-02 -2.07E-02 -2.04E-02 -2.04E-02 -2.07E-02Std Dev Un-Biased 4.92E-04 5.02E-04 5.13E-04 5.24E-04 5.42E-04 5.44E-04 5.16E-04Ps90%/90% (+KTL) Un-Biased -1.98E-02 -1.96E-02 -1.94E-02 -1.92E-02 -1.89E-02 -1.89E-02 -1.93E-02Ps90%/90% (-KTL) Un-Biased -2.25E-02 -2.24E-02 -2.22E-02 -2.21E-02 -2.19E-02 -2.19E-02 -2.21E-02Specification MAX -1.20E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS FAIL FAIL PASS

Total Dose (krad(Si))

Page 363: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

363

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

5.00E-03

1.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

3V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.178. Plot of Positive Short-Circuit Current @ 3V #4 (A) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 364: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

364

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.178. Raw data for Positive Short-Circuit Current @ 3V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 3V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.02E-02 -1.99E-02 -1.94E-02 -1.91E-02 -7.11E-03 -1.38E-02 -1.94E-02879 -2.02E-02 -1.99E-02 -1.95E-02 -1.91E-02 -1.95E-02 -1.97E-02 -1.98E-02882 -2.08E-02 -2.05E-02 -2.00E-02 -1.95E-02 -6.24E-03 -1.30E-02 -2.00E-02883 -1.95E-02 -1.91E-02 -1.86E-02 -1.84E-02 -1.59E-02 -1.80E-02 -1.87E-02885 -2.00E-02 -1.97E-02 -1.93E-02 -1.96E-02 -1.85E-02 -1.90E-02 -1.94E-02886 -2.07E-02 -2.05E-02 -2.04E-02 -2.02E-02 -2.00E-02 -2.00E-02 -2.03E-02887 -2.02E-02 -2.00E-02 -1.98E-02 -1.97E-02 -1.95E-02 -1.95E-02 -1.98E-02891 -2.02E-02 -2.00E-02 -1.98E-02 -1.97E-02 -1.95E-02 -1.95E-02 -1.98E-02892 -2.04E-02 -2.02E-02 -2.00E-02 -1.98E-02 -1.95E-02 -1.95E-02 -1.99E-02895 -1.95E-02 -1.93E-02 -1.92E-02 -1.91E-02 -1.88E-02 -1.88E-02 -1.91E-02896 -1.93E-02 -1.93E-02 -1.93E-02 -1.93E-02 -1.93E-02 -1.93E-02 -1.93E-02

Biased StatisticsAverage Biased -2.01E-02 -1.98E-02 -1.94E-02 -1.91E-02 -1.34E-02 -1.67E-02 -1.95E-02Std Dev Biased 4.72E-04 4.87E-04 4.93E-04 4.89E-04 6.33E-03 3.06E-03 5.10E-04Ps90%/90% (+KTL) Biased -1.88E-02 -1.85E-02 -1.80E-02 -1.78E-02 3.91E-03 -8.32E-03 -1.81E-02Ps90%/90% (-KTL) Biased -2.14E-02 -2.11E-02 -2.07E-02 -2.05E-02 -3.08E-02 -2.51E-02 -2.09E-02Un-Biased StatisticsAverage Un-Biased -2.02E-02 -2.00E-02 -1.98E-02 -1.97E-02 -1.94E-02 -1.94E-02 -1.98E-02Std Dev Un-Biased 4.28E-04 4.32E-04 4.25E-04 4.25E-04 4.44E-04 4.36E-04 4.22E-04Ps90%/90% (+KTL) Un-Biased -1.90E-02 -1.88E-02 -1.87E-02 -1.85E-02 -1.82E-02 -1.82E-02 -1.86E-02Ps90%/90% (-KTL) Un-Biased -2.14E-02 -2.12E-02 -2.10E-02 -2.09E-02 -2.06E-02 -2.06E-02 -2.09E-02Specification MAX -1.20E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 365: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

365

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

3.00E-02

3.50E-02

4.00E-02

4.50E-02

5.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 3

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.179. Plot of Negative Short-Circuit Current @ 3V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 366: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

366

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.179. Raw data for Negative Short-Circuit Current @ 3V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 3V #1 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.53E-02 4.53E-02 4.51E-02 4.51E-02 4.57E-02 4.58E-02 4.51E-02879 4.52E-02 4.55E-02 4.54E-02 4.53E-02 4.50E-02 4.55E-02 4.52E-02882 4.58E-02 4.57E-02 4.56E-02 4.56E-02 4.61E-02 4.63E-02 4.54E-02883 4.40E-02 4.38E-02 4.36E-02 4.35E-02 4.41E-02 4.43E-02 4.35E-02885 4.54E-02 4.53E-02 4.52E-02 4.50E-02 4.50E-02 4.53E-02 4.49E-02886 4.56E-02 4.56E-02 4.55E-02 4.53E-02 4.51E-02 4.55E-02 4.54E-02887 4.51E-02 4.51E-02 4.49E-02 4.48E-02 4.45E-02 4.50E-02 4.48E-02891 4.54E-02 4.54E-02 4.52E-02 4.51E-02 4.48E-02 4.52E-02 4.51E-02892 4.50E-02 4.49E-02 4.47E-02 4.45E-02 4.42E-02 4.46E-02 4.46E-02895 4.43E-02 4.43E-02 4.41E-02 4.39E-02 4.37E-02 4.41E-02 4.40E-02896 4.42E-02 4.43E-02 4.42E-02 4.41E-02 4.41E-02 4.44E-02 4.42E-02

Biased StatisticsAverage Biased 4.51E-02 4.51E-02 4.50E-02 4.49E-02 4.52E-02 4.54E-02 4.48E-02Std Dev Biased 7.03E-04 7.53E-04 7.84E-04 8.16E-04 7.78E-04 7.34E-04 7.98E-04Ps90%/90% (+KTL) Biased 4.71E-02 4.72E-02 4.71E-02 4.71E-02 4.73E-02 4.74E-02 4.70E-02Ps90%/90% (-KTL) Biased 4.32E-02 4.30E-02 4.28E-02 4.26E-02 4.31E-02 4.34E-02 4.26E-02Un-Biased StatisticsAverage Un-Biased 4.51E-02 4.51E-02 4.49E-02 4.47E-02 4.45E-02 4.49E-02 4.48E-02Std Dev Un-Biased 4.92E-04 5.22E-04 5.38E-04 5.36E-04 5.54E-04 5.73E-04 5.22E-04Ps90%/90% (+KTL) Un-Biased 4.64E-02 4.65E-02 4.63E-02 4.62E-02 4.60E-02 4.65E-02 4.62E-02Ps90%/90% (-KTL) Un-Biased 4.37E-02 4.36E-02 4.34E-02 4.32E-02 4.30E-02 4.33E-02 4.33E-02Specification MIN 1.20E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 367: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

367

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

3.00E-02

3.50E-02

4.00E-02

4.50E-02

5.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 3

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.180. Plot of Negative Short-Circuit Current @ 3V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 368: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

368

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.180. Raw data for Negative Short-Circuit Current @ 3V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 3V #2 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.47E-02 4.47E-02 4.46E-02 4.45E-02 4.51E-02 4.52E-02 4.46E-02879 4.47E-02 4.57E-02 4.56E-02 4.54E-02 4.52E-02 4.56E-02 4.54E-02882 4.56E-02 4.55E-02 4.54E-02 4.55E-02 4.60E-02 4.61E-02 4.52E-02883 4.42E-02 4.40E-02 4.38E-02 4.37E-02 4.44E-02 4.46E-02 4.36E-02885 4.43E-02 4.42E-02 4.40E-02 4.39E-02 4.40E-02 4.43E-02 4.38E-02886 4.55E-02 4.56E-02 4.54E-02 4.52E-02 4.50E-02 4.55E-02 4.53E-02887 4.58E-02 4.58E-02 4.56E-02 4.54E-02 4.51E-02 4.55E-02 4.55E-02891 4.60E-02 4.60E-02 4.58E-02 4.56E-02 4.54E-02 4.58E-02 4.57E-02892 4.48E-02 4.47E-02 4.45E-02 4.44E-02 4.41E-02 4.45E-02 4.45E-02895 4.67E-02 4.66E-02 4.64E-02 4.63E-02 4.60E-02 4.65E-02 4.64E-02896 4.51E-02 4.51E-02 4.51E-02 4.50E-02 4.50E-02 4.53E-02 4.51E-02

Biased StatisticsAverage Biased 4.47E-02 4.48E-02 4.47E-02 4.46E-02 4.49E-02 4.51E-02 4.45E-02Std Dev Biased 5.54E-04 7.47E-04 7.80E-04 8.22E-04 7.50E-04 7.40E-04 8.34E-04Ps90%/90% (+KTL) Biased 4.62E-02 4.69E-02 4.68E-02 4.68E-02 4.70E-02 4.72E-02 4.68E-02Ps90%/90% (-KTL) Biased 4.32E-02 4.28E-02 4.25E-02 4.23E-02 4.29E-02 4.31E-02 4.22E-02Un-Biased StatisticsAverage Un-Biased 4.58E-02 4.57E-02 4.55E-02 4.54E-02 4.51E-02 4.56E-02 4.54E-02Std Dev Un-Biased 6.83E-04 6.89E-04 6.84E-04 6.95E-04 6.91E-04 7.13E-04 6.88E-04Ps90%/90% (+KTL) Un-Biased 4.76E-02 4.76E-02 4.74E-02 4.73E-02 4.70E-02 4.75E-02 4.73E-02Ps90%/90% (-KTL) Un-Biased 4.39E-02 4.38E-02 4.37E-02 4.35E-02 4.32E-02 4.36E-02 4.36E-02Specification MIN 1.20E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 369: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

369

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

3.00E-02

3.50E-02

4.00E-02

4.50E-02

5.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 3

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.181. Plot of Negative Short-Circuit Current @ 3V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 370: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

370

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.181. Raw data for Negative Short-Circuit Current @ 3V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 3V #3 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.52E-02 4.51E-02 4.50E-02 4.49E-02 4.56E-02 4.56E-02 4.50E-02879 4.51E-02 4.64E-02 4.62E-02 4.62E-02 4.58E-02 4.62E-02 4.61E-02882 4.62E-02 4.61E-02 4.60E-02 4.60E-02 4.65E-02 4.67E-02 4.58E-02883 4.49E-02 4.47E-02 4.45E-02 4.44E-02 4.51E-02 4.53E-02 4.43E-02885 4.48E-02 4.47E-02 4.45E-02 4.44E-02 4.45E-02 4.48E-02 4.43E-02886 4.60E-02 4.61E-02 4.59E-02 4.57E-02 4.55E-02 4.60E-02 4.58E-02887 4.64E-02 4.64E-02 4.62E-02 4.60E-02 4.57E-02 4.61E-02 4.61E-02891 4.64E-02 4.63E-02 4.62E-02 4.60E-02 4.58E-02 4.62E-02 4.60E-02892 4.53E-02 4.52E-02 4.50E-02 4.49E-02 4.47E-02 4.50E-02 4.50E-02895 4.72E-02 4.72E-02 4.70E-02 4.68E-02 4.66E-02 4.70E-02 4.69E-02896 4.56E-02 4.57E-02 4.57E-02 4.56E-02 4.56E-02 4.59E-02 4.56E-02

Biased StatisticsAverage Biased 4.52E-02 4.54E-02 4.52E-02 4.52E-02 4.55E-02 4.57E-02 4.51E-02Std Dev Biased 5.79E-04 7.88E-04 7.98E-04 8.54E-04 7.49E-04 7.59E-04 8.20E-04Ps90%/90% (+KTL) Biased 4.68E-02 4.76E-02 4.74E-02 4.75E-02 4.75E-02 4.78E-02 4.73E-02Ps90%/90% (-KTL) Biased 4.36E-02 4.32E-02 4.31E-02 4.28E-02 4.34E-02 4.36E-02 4.28E-02Un-Biased StatisticsAverage Un-Biased 4.63E-02 4.62E-02 4.60E-02 4.59E-02 4.56E-02 4.61E-02 4.59E-02Std Dev Un-Biased 6.84E-04 6.86E-04 6.86E-04 6.89E-04 6.88E-04 7.00E-04 6.87E-04Ps90%/90% (+KTL) Un-Biased 4.81E-02 4.81E-02 4.79E-02 4.78E-02 4.75E-02 4.80E-02 4.78E-02Ps90%/90% (-KTL) Un-Biased 4.44E-02 4.43E-02 4.42E-02 4.40E-02 4.38E-02 4.41E-02 4.41E-02Specification MIN 1.20E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 371: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

371

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

3.00E-02

3.50E-02

4.00E-02

4.50E-02

5.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 3

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.182. Plot of Negative Short-Circuit Current @ 3V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 372: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

372

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.182. Raw data for Negative Short-Circuit Current @ 3V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 3V #4 (A)24 hr

Anneal168 hr Anneal

Device 0 10 20 30 50 60 70878 4.47E-02 4.47E-02 4.46E-02 4.45E-02 4.52E-02 4.52E-02 4.46E-02879 4.47E-02 4.48E-02 4.47E-02 4.46E-02 4.43E-02 4.48E-02 4.46E-02882 4.51E-02 4.50E-02 4.49E-02 4.49E-02 4.54E-02 4.56E-02 4.48E-02883 4.33E-02 4.31E-02 4.29E-02 4.28E-02 4.32E-02 4.33E-02 4.27E-02885 4.49E-02 4.49E-02 4.47E-02 4.46E-02 4.46E-02 4.49E-02 4.45E-02886 4.50E-02 4.51E-02 4.49E-02 4.47E-02 4.45E-02 4.50E-02 4.48E-02887 4.44E-02 4.44E-02 4.42E-02 4.41E-02 4.39E-02 4.43E-02 4.42E-02891 4.47E-02 4.46E-02 4.45E-02 4.43E-02 4.41E-02 4.45E-02 4.44E-02892 4.43E-02 4.42E-02 4.40E-02 4.39E-02 4.36E-02 4.40E-02 4.39E-02895 4.37E-02 4.36E-02 4.34E-02 4.33E-02 4.31E-02 4.34E-02 4.34E-02896 4.35E-02 4.35E-02 4.35E-02 4.34E-02 4.34E-02 4.37E-02 4.34E-02

Biased StatisticsAverage Biased 4.45E-02 4.45E-02 4.44E-02 4.43E-02 4.45E-02 4.48E-02 4.42E-02Std Dev Biased 7.32E-04 7.77E-04 8.03E-04 8.42E-04 8.75E-04 8.64E-04 8.67E-04Ps90%/90% (+KTL) Biased 4.65E-02 4.66E-02 4.66E-02 4.66E-02 4.69E-02 4.71E-02 4.66E-02Ps90%/90% (-KTL) Biased 4.25E-02 4.24E-02 4.22E-02 4.20E-02 4.21E-02 4.24E-02 4.18E-02Un-Biased StatisticsAverage Un-Biased 4.44E-02 4.44E-02 4.42E-02 4.41E-02 4.38E-02 4.42E-02 4.41E-02Std Dev Un-Biased 4.99E-04 5.39E-04 5.38E-04 5.33E-04 5.51E-04 5.81E-04 5.27E-04Ps90%/90% (+KTL) Un-Biased 4.58E-02 4.59E-02 4.57E-02 4.55E-02 4.53E-02 4.58E-02 4.56E-02Ps90%/90% (-KTL) Un-Biased 4.31E-02 4.29E-02 4.27E-02 4.26E-02 4.23E-02 4.26E-02 4.27E-02Specification MIN 1.20E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 373: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

373

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.00E-03

5.50E-03

6.00E-03

6.50E-03

7.00E-03

7.50E-03

8.00E-03

8.50E-03

9.00E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Supp

ly C

urre

nt @

5V

(A)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.183. Plot of Positive Supply Current @ 5V (A) versus total dose. The data show no significantchange with radiation. The solid diamonds are the average of the measured data points for the sampleirradiated under electrical bias while the shaded diamonds are the average of the measured data points for theunits irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the datapoints after application of the KTL statistics on the sample irradiated under electrical bias while the gray lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 374: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

374

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.183. Raw data for Positive Supply Current @ 5V (A) versus total dose, including thestatistical analysis, specification and the status of the testing (pass/fail).

Positive Supply Current @ 5V (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.55E-03 7.46E-03 7.40E-03 7.35E-03 7.28E-03 7.30E-03 7.34E-03879 7.36E-03 7.24E-03 7.19E-03 7.12E-03 7.15E-03 7.16E-03 7.20E-03882 7.60E-03 7.53E-03 7.48E-03 7.43E-03 7.35E-03 7.36E-03 7.41E-03883 7.45E-03 7.35E-03 7.28E-03 7.23E-03 7.11E-03 7.14E-03 7.18E-03885 7.46E-03 7.38E-03 7.32E-03 7.35E-03 7.20E-03 7.23E-03 7.26E-03886 7.45E-03 7.39E-03 7.37E-03 7.34E-03 7.30E-03 7.29E-03 7.33E-03887 7.42E-03 7.40E-03 7.37E-03 7.34E-03 7.28E-03 7.28E-03 7.34E-03891 7.50E-03 7.48E-03 7.45E-03 7.42E-03 7.38E-03 7.37E-03 7.42E-03892 7.37E-03 7.30E-03 7.27E-03 7.24E-03 7.16E-03 7.16E-03 7.25E-03895 7.56E-03 7.51E-03 7.48E-03 7.46E-03 7.40E-03 7.39E-03 7.45E-03896 7.80E-03 7.78E-03 7.79E-03 7.80E-03 7.79E-03 7.79E-03 7.80E-03

Biased StatisticsAverage Biased 7.48E-03 7.39E-03 7.33E-03 7.30E-03 7.22E-03 7.24E-03 7.28E-03Std Dev Biased 9.34E-05 1.10E-04 1.11E-04 1.22E-04 9.73E-05 9.28E-05 9.65E-05Ps90%/90% (+KTL) Biased 7.74E-03 7.69E-03 7.64E-03 7.63E-03 7.48E-03 7.49E-03 7.54E-03Ps90%/90% (-KTL) Biased 7.23E-03 7.09E-03 7.03E-03 6.96E-03 6.95E-03 6.98E-03 7.01E-03Un-Biased StatisticsAverage Un-Biased 7.46E-03 7.42E-03 7.39E-03 7.36E-03 7.30E-03 7.30E-03 7.36E-03Std Dev Un-Biased 7.31E-05 8.26E-05 8.20E-05 8.49E-05 9.53E-05 9.09E-05 7.92E-05Ps90%/90% (+KTL) Un-Biased 7.66E-03 7.64E-03 7.61E-03 7.59E-03 7.57E-03 7.55E-03 7.58E-03Ps90%/90% (-KTL) Un-Biased 7.26E-03 7.19E-03 7.16E-03 7.13E-03 7.04E-03 7.05E-03 7.14E-03Specification MAX 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 375: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

375

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-9.00E-03

-8.50E-03

-8.00E-03

-7.50E-03

-7.00E-03

-6.50E-03

-6.00E-03

-5.50E-03

-5.00E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Su

pply

Cur

rent

@ 5

V (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.184. Plot of Negative Supply Current @ 5V (A) versus total dose. The data show no significantchange with radiation. The solid diamonds are the average of the measured data points for the sampleirradiated under electrical bias while the shaded diamonds are the average of the measured data points for theunits irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the datapoints after application of the KTL statistics on the sample irradiated under electrical bias while the gray lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samplesirradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimumand/or maximum specification value as defined in the datasheet and/or test plan.

Page 376: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

376

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.184. Raw data for Negative Supply Current @ 5V (A) versus total dose, including thestatistical analysis, specification and the status of the testing (pass/fail).

Negative Supply Current @ 5V (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -7.55E-03 -7.45E-03 -7.39E-03 -7.34E-03 -7.27E-03 -7.29E-03 -7.33E-03879 -7.36E-03 -7.23E-03 -7.18E-03 -7.11E-03 -7.14E-03 -7.15E-03 -7.19E-03882 -7.60E-03 -7.52E-03 -7.47E-03 -7.42E-03 -7.34E-03 -7.35E-03 -7.40E-03883 -7.44E-03 -7.34E-03 -7.28E-03 -7.21E-03 -7.10E-03 -7.13E-03 -7.18E-03885 -7.46E-03 -7.37E-03 -7.31E-03 -7.34E-03 -7.20E-03 -7.22E-03 -7.25E-03886 -7.44E-03 -7.38E-03 -7.36E-03 -7.34E-03 -7.29E-03 -7.28E-03 -7.32E-03887 -7.41E-03 -7.39E-03 -7.36E-03 -7.33E-03 -7.27E-03 -7.27E-03 -7.33E-03891 -7.49E-03 -7.47E-03 -7.44E-03 -7.41E-03 -7.37E-03 -7.36E-03 -7.41E-03892 -7.36E-03 -7.30E-03 -7.26E-03 -7.23E-03 -7.15E-03 -7.15E-03 -7.24E-03895 -7.55E-03 -7.50E-03 -7.47E-03 -7.45E-03 -7.39E-03 -7.38E-03 -7.44E-03896 -7.79E-03 -7.77E-03 -7.78E-03 -7.79E-03 -7.79E-03 -7.78E-03 -7.79E-03

Biased StatisticsAverage Biased -7.48E-03 -7.38E-03 -7.33E-03 -7.28E-03 -7.21E-03 -7.23E-03 -7.27E-03Std Dev Biased 9.44E-05 1.10E-04 1.10E-04 1.23E-04 9.70E-05 9.28E-05 9.41E-05Ps90%/90% (+KTL) Biased -7.22E-03 -7.08E-03 -7.02E-03 -6.95E-03 -6.94E-03 -6.97E-03 -7.01E-03Ps90%/90% (-KTL) Biased -7.74E-03 -7.68E-03 -7.63E-03 -7.62E-03 -7.48E-03 -7.48E-03 -7.53E-03Un-Biased StatisticsAverage Un-Biased -7.45E-03 -7.41E-03 -7.38E-03 -7.35E-03 -7.29E-03 -7.29E-03 -7.35E-03Std Dev Un-Biased 7.31E-05 7.92E-05 8.20E-05 8.44E-05 9.53E-05 9.09E-05 7.92E-05Ps90%/90% (+KTL) Un-Biased -7.25E-03 -7.19E-03 -7.15E-03 -7.12E-03 -7.03E-03 -7.04E-03 -7.13E-03Ps90%/90% (-KTL) Un-Biased -7.65E-03 -7.63E-03 -7.60E-03 -7.58E-03 -7.56E-03 -7.54E-03 -7.57E-03Specification MIN -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03 -8.80E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 377: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

377

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=0

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.185. Plot of Input Offset Voltage @ 5V, VCM=0V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 378: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

378

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.185. Raw data for Input Offset Voltage @ 5V, VCM=0V #1 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=0V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.00E-04 -3.13E-04 -3.02E-04 -2.95E-04 -2.93E-04 -2.96E-04 -3.20E-04879 8.92E-05 4.98E-05 6.16E-05 4.81E-05 4.21E-05 3.58E-05 4.38E-05882 -7.73E-05 -8.57E-05 -7.94E-05 -8.28E-05 -8.40E-05 -8.07E-05 -9.55E-05883 1.60E-05 1.97E-06 2.82E-06 2.05E-05 6.08E-06 2.45E-06 -1.37E-05885 -2.46E-04 -2.57E-04 -2.50E-04 -2.55E-04 -2.48E-04 -2.51E-04 -2.68E-04886 1.69E-04 1.46E-04 1.41E-04 1.36E-04 1.29E-04 1.28E-04 1.24E-04887 -2.13E-04 -2.26E-04 -2.28E-04 -2.34E-04 -2.44E-04 -2.43E-04 -2.42E-04891 -2.18E-05 -3.56E-05 -4.08E-05 -4.60E-05 -5.14E-05 -5.61E-05 -5.67E-05892 -2.39E-04 -2.51E-04 -2.54E-04 -2.63E-04 -2.66E-04 -2.66E-04 -2.68E-04895 -1.03E-04 -1.22E-04 -1.27E-04 -1.30E-04 -1.46E-04 -1.47E-04 -1.35E-04896 1.39E-04 1.35E-04 1.36E-04 1.38E-04 1.37E-04 1.35E-04 1.39E-04

Biased StatisticsAverage Biased -1.04E-04 -1.21E-04 -1.13E-04 -1.13E-04 -1.16E-04 -1.18E-04 -1.31E-04Std Dev Biased 1.67E-04 1.59E-04 1.58E-04 1.57E-04 1.50E-04 1.49E-04 1.58E-04Ps90%/90% (+KTL) Biased 3.53E-04 3.14E-04 3.19E-04 3.16E-04 2.96E-04 2.91E-04 3.03E-04Ps90%/90% (-KTL) Biased -5.61E-04 -5.56E-04 -5.46E-04 -5.42E-04 -5.27E-04 -5.27E-04 -5.64E-04Un-Biased StatisticsAverage Un-Biased -8.17E-05 -9.76E-05 -1.02E-04 -1.08E-04 -1.16E-04 -1.17E-04 -1.16E-04Std Dev Un-Biased 1.65E-04 1.61E-04 1.60E-04 1.61E-04 1.61E-04 1.60E-04 1.59E-04Ps90%/90% (+KTL) Un-Biased 3.71E-04 3.44E-04 3.37E-04 3.34E-04 3.27E-04 3.22E-04 3.19E-04Ps90%/90% (-KTL) Un-Biased -5.34E-04 -5.40E-04 -5.41E-04 -5.49E-04 -5.58E-04 -5.56E-04 -5.51E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 379: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

379

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=0

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.186. Plot of Input Offset Voltage @ 5V, VCM=0V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 380: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

380

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.186. Raw data for Input Offset Voltage @ 5V, VCM=0V #2 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=0V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.52E-04 -2.72E-04 -2.69E-04 -2.34E-04 -2.01E-04 -2.40E-04 -2.81E-04879 -6.04E-05 -6.53E-05 -4.65E-05 -5.71E-05 -6.63E-05 -6.36E-05 -6.63E-05882 1.07E-04 8.54E-05 8.23E-05 8.18E-05 7.90E-05 7.94E-05 6.96E-05883 -7.30E-05 -9.10E-05 -7.99E-05 -6.17E-05 -7.36E-05 -3.29E-05 -8.90E-05885 -2.48E-05 -2.78E-05 -3.83E-06 -2.11E-05 -2.21E-05 -3.57E-05 -4.10E-05886 2.02E-04 1.81E-04 1.76E-04 1.72E-04 1.66E-04 1.64E-04 1.69E-04887 -1.68E-04 -1.64E-04 -1.72E-04 -1.74E-04 -1.83E-04 -1.90E-04 -2.00E-04891 2.81E-04 2.74E-04 2.71E-04 2.65E-04 2.58E-04 2.53E-04 2.66E-04892 1.15E-04 1.02E-04 9.86E-05 9.18E-05 8.68E-05 7.60E-05 7.79E-05895 6.80E-06 -8.06E-06 -9.99E-06 -1.26E-05 -1.62E-05 -2.04E-05 -2.88E-05896 1.21E-04 1.18E-04 1.18E-04 1.21E-04 1.19E-04 1.19E-04 1.20E-04

Biased StatisticsAverage Biased -6.06E-05 -7.41E-05 -6.33E-05 -5.85E-05 -5.67E-05 -5.85E-05 -8.16E-05Std Dev Biased 1.28E-04 1.29E-04 1.30E-04 1.14E-04 1.01E-04 1.15E-04 1.27E-04Ps90%/90% (+KTL) Biased 2.92E-04 2.81E-04 2.93E-04 2.54E-04 2.20E-04 2.57E-04 2.67E-04Ps90%/90% (-KTL) Biased -4.13E-04 -4.29E-04 -4.19E-04 -3.71E-04 -3.33E-04 -3.74E-04 -4.30E-04Un-Biased StatisticsAverage Un-Biased 8.74E-05 7.70E-05 7.28E-05 6.83E-05 6.21E-05 5.67E-05 5.67E-05Std Dev Un-Biased 1.76E-04 1.70E-04 1.71E-04 1.70E-04 1.70E-04 1.71E-04 1.80E-04Ps90%/90% (+KTL) Un-Biased 5.69E-04 5.43E-04 5.43E-04 5.34E-04 5.29E-04 5.26E-04 5.51E-04Ps90%/90% (-KTL) Un-Biased -3.94E-04 -3.89E-04 -3.97E-04 -3.97E-04 -4.05E-04 -4.13E-04 -4.38E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 381: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

381

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=0

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.187. Plot of Input Offset Voltage @ 5V, VCM=0V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 382: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

382

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.187. Raw data for Input Offset Voltage @ 5V, VCM=0V #3 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=0V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.71E-05 -1.78E-06 3.78E-06 9.82E-06 7.41E-06 7.41E-06 -6.85E-06879 1.91E-04 1.47E-04 1.63E-04 1.48E-04 1.41E-04 1.37E-04 1.43E-04882 -1.23E-04 -1.53E-04 -1.44E-04 -1.44E-04 -1.48E-04 -1.49E-04 -1.63E-04883 1.41E-04 1.16E-04 1.15E-04 1.31E-04 1.09E-04 1.14E-04 8.17E-05885 -1.94E-04 -2.10E-04 -2.06E-04 -2.05E-04 -2.14E-04 -2.14E-04 -2.38E-04886 -3.37E-04 -3.50E-04 -3.57E-04 -3.60E-04 -3.66E-04 -3.65E-04 -3.68E-04887 -1.26E-04 -1.23E-04 -1.32E-04 -1.40E-04 -1.54E-04 -1.59E-04 -1.36E-04891 -4.25E-05 -5.25E-05 -5.53E-05 -6.12E-05 -6.25E-05 -6.54E-05 -7.07E-05892 1.53E-05 2.09E-06 -2.50E-06 -3.22E-06 -7.09E-06 -1.05E-05 -1.39E-05895 -3.79E-05 -5.92E-05 -6.11E-05 -6.50E-05 -6.64E-05 -7.22E-05 -6.40E-05896 3.42E-04 3.34E-04 3.37E-04 3.40E-04 3.39E-04 3.38E-04 3.40E-04

Biased StatisticsAverage Biased 8.57E-06 -2.03E-05 -1.36E-05 -1.22E-05 -2.08E-05 -2.10E-05 -3.68E-05Std Dev Biased 1.66E-04 1.58E-04 1.60E-04 1.59E-04 1.56E-04 1.56E-04 1.61E-04Ps90%/90% (+KTL) Biased 4.62E-04 4.14E-04 4.24E-04 4.24E-04 4.07E-04 4.08E-04 4.05E-04Ps90%/90% (-KTL) Biased -4.45E-04 -4.54E-04 -4.51E-04 -4.48E-04 -4.49E-04 -4.50E-04 -4.78E-04Un-Biased StatisticsAverage Un-Biased -1.06E-04 -1.17E-04 -1.21E-04 -1.26E-04 -1.31E-04 -1.34E-04 -1.31E-04Std Dev Un-Biased 1.39E-04 1.38E-04 1.39E-04 1.40E-04 1.41E-04 1.39E-04 1.40E-04Ps90%/90% (+KTL) Un-Biased 2.75E-04 2.62E-04 2.60E-04 2.57E-04 2.57E-04 2.48E-04 2.53E-04Ps90%/90% (-KTL) Un-Biased -4.87E-04 -4.95E-04 -5.03E-04 -5.09E-04 -5.19E-04 -5.16E-04 -5.14E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 383: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

383

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=0

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.188. Plot of Input Offset Voltage @ 5V, VCM=0V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 384: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

384

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.188. Raw data for Input Offset Voltage @ 5V, VCM=0V #4 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=0V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.79E-04 -3.01E-04 -2.90E-04 -2.86E-04 -2.78E-04 -2.78E-04 -2.92E-04879 1.74E-04 1.40E-04 1.52E-04 1.39E-04 1.38E-04 1.36E-04 1.21E-04882 -2.05E-04 -2.31E-04 -2.17E-04 -2.13E-04 -2.13E-04 -2.15E-04 -2.25E-04883 -5.94E-05 -7.39E-05 -6.75E-05 -4.48E-05 -6.65E-05 -6.65E-05 -8.85E-05885 3.80E-05 1.22E-05 1.41E-05 1.82E-05 9.58E-06 6.20E-06 -2.28E-05886 1.70E-04 1.47E-04 1.39E-04 1.34E-04 1.30E-04 1.25E-04 1.22E-04887 -2.41E-04 -2.57E-04 -2.58E-04 -2.60E-04 -2.69E-04 -2.71E-04 -2.69E-04891 1.23E-04 1.10E-04 1.06E-04 1.01E-04 9.53E-05 9.20E-05 9.21E-05892 1.79E-04 1.78E-04 1.72E-04 1.78E-04 1.66E-04 1.66E-04 1.76E-04895 1.60E-04 1.42E-04 1.34E-04 1.27E-04 1.12E-04 1.08E-04 1.16E-04896 1.01E-04 1.03E-04 1.00E-04 1.06E-04 1.03E-04 9.88E-05 1.05E-04

Biased StatisticsAverage Biased -6.65E-05 -9.08E-05 -8.17E-05 -7.72E-05 -8.18E-05 -8.34E-05 -1.01E-04Std Dev Biased 1.82E-04 1.79E-04 1.77E-04 1.72E-04 1.68E-04 1.67E-04 1.64E-04Ps90%/90% (+KTL) Biased 4.34E-04 3.99E-04 4.05E-04 3.95E-04 3.78E-04 3.75E-04 3.48E-04Ps90%/90% (-KTL) Biased -5.67E-04 -5.81E-04 -5.68E-04 -5.50E-04 -5.41E-04 -5.42E-04 -5.50E-04Un-Biased StatisticsAverage Un-Biased 7.84E-05 6.41E-05 5.87E-05 5.60E-05 4.69E-05 4.40E-05 4.74E-05Std Dev Un-Biased 1.80E-04 1.81E-04 1.78E-04 1.79E-04 1.79E-04 1.78E-04 1.79E-04Ps90%/90% (+KTL) Un-Biased 5.71E-04 5.60E-04 5.48E-04 5.46E-04 5.36E-04 5.33E-04 5.39E-04Ps90%/90% (-KTL) Un-Biased -4.15E-04 -4.32E-04 -4.31E-04 -4.34E-04 -4.43E-04 -4.45E-04 -4.44E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 385: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

385

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=0

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.189. Plot of Input Offset Current @ 5V, VCM=0V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 386: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

386

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.189. Raw data for Input Offset Current @ 5V, VCM=0V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=0V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 8.40E-10 7.66E-10 1.28E-09 1.40E-09 3.78E-10 2.18E-10 5.97E-10879 9.90E-10 8.00E-10 7.74E-10 6.81E-10 2.74E-09 1.96E-09 1.60E-09882 -4.12E-09 -4.12E-09 -4.05E-09 -4.34E-09 -4.30E-09 -3.73E-09 -3.91E-09883 -2.31E-09 -1.81E-09 -1.64E-09 -1.82E-09 -2.21E-09 -2.37E-09 -2.40E-09885 -2.41E-09 -2.83E-09 -2.64E-09 -9.77E-10 -1.65E-09 -2.45E-09 -2.27E-09886 4.58E-09 4.31E-09 3.90E-09 3.64E-09 3.98E-09 3.92E-09 3.83E-09887 2.76E-09 3.00E-09 2.78E-09 1.98E-09 2.28E-09 2.19E-09 2.42E-09891 -4.69E-10 -4.47E-10 -6.19E-10 -6.00E-12 -3.30E-10 -4.60E-10 -2.98E-09892 -2.52E-09 -2.74E-09 -2.85E-09 -2.65E-09 -2.70E-09 -3.09E-09 -2.52E-09895 9.56E-10 1.27E-09 1.60E-09 1.59E-09 2.22E-09 1.99E-09 1.75E-09896 8.24E-10 8.04E-10 8.07E-10 8.18E-10 8.28E-10 8.82E-10 8.24E-10

Biased StatisticsAverage Biased -1.40E-09 -1.44E-09 -1.26E-09 -1.01E-09 -1.01E-09 -1.27E-09 -1.28E-09Std Dev Biased 2.23E-09 2.19E-09 2.26E-09 2.26E-09 2.68E-09 2.31E-09 2.29E-09Ps90%/90% (+KTL) Biased 4.72E-09 4.56E-09 4.94E-09 5.18E-09 6.33E-09 5.05E-09 5.00E-09Ps90%/90% (-KTL) Biased -7.53E-09 -7.43E-09 -7.45E-09 -7.21E-09 -8.35E-09 -7.60E-09 -7.56E-09Un-Biased StatisticsAverage Un-Biased 1.06E-09 1.08E-09 9.62E-10 9.12E-10 1.09E-09 9.11E-10 4.99E-10Std Dev Un-Biased 2.76E-09 2.79E-09 2.71E-09 2.38E-09 2.62E-09 2.73E-09 3.06E-09Ps90%/90% (+KTL) Un-Biased 8.63E-09 8.73E-09 8.39E-09 7.43E-09 8.27E-09 8.39E-09 8.90E-09Ps90%/90% (-KTL) Un-Biased -6.51E-09 -6.57E-09 -6.47E-09 -5.60E-09 -6.09E-09 -6.57E-09 -7.90E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 387: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

387

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=0

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.190. Plot of Input Offset Current @ 5V, VCM=0V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 388: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

388

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.190. Raw data for Input Offset Current @ 5V, VCM=0V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=0V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -9.86E-10 -1.44E-09 -1.27E-09 1.76E-09 4.84E-09 -9.59E-10 -6.14E-10879 -6.39E-09 -6.99E-09 -6.72E-09 -6.07E-09 -4.93E-09 -5.26E-09 -5.65E-09882 -3.44E-09 -3.91E-09 -3.88E-09 -3.59E-09 -3.51E-09 -4.16E-09 -3.62E-09883 -2.69E-10 -7.01E-10 -5.06E-10 -7.20E-11 7.26E-10 7.24E-09 -3.11E-10885 7.51E-10 1.26E-09 2.44E-09 2.87E-09 4.42E-10 1.03E-09 1.06E-09886 -3.56E-10 2.00E-11 -5.70E-11 2.38E-10 9.17E-10 1.02E-09 8.70E-11887 -6.70E-09 -6.49E-09 -6.48E-09 -6.18E-09 -6.74E-09 -6.65E-09 -6.77E-09891 5.66E-10 5.35E-10 5.85E-10 5.45E-10 1.81E-10 4.75E-10 4.27E-10892 1.75E-09 2.10E-09 2.02E-09 2.29E-09 2.21E-09 2.00E-09 2.18E-09895 2.90E-09 2.55E-09 2.49E-09 2.44E-09 2.47E-09 2.50E-09 2.22E-09896 2.23E-09 2.27E-09 2.29E-09 2.24E-09 2.25E-09 2.21E-09 2.21E-09

Biased StatisticsAverage Biased -2.07E-09 -2.35E-09 -1.99E-09 -1.02E-09 -4.87E-10 -4.20E-10 -1.83E-09Std Dev Biased 2.87E-09 3.18E-09 3.47E-09 3.74E-09 3.86E-09 4.96E-09 2.74E-09Ps90%/90% (+KTL) Biased 5.80E-09 6.37E-09 7.54E-09 9.23E-09 1.01E-08 1.32E-08 5.67E-09Ps90%/90% (-KTL) Biased -9.94E-09 -1.11E-08 -1.15E-08 -1.13E-08 -1.11E-08 -1.40E-08 -9.33E-09Un-Biased StatisticsAverage Un-Biased -3.67E-10 -2.56E-10 -2.88E-10 -1.33E-10 -1.93E-10 -1.31E-10 -3.71E-10Std Dev Un-Biased 3.75E-09 3.64E-09 3.61E-09 3.53E-09 3.78E-09 3.73E-09 3.71E-09Ps90%/90% (+KTL) Un-Biased 9.90E-09 9.72E-09 9.62E-09 9.54E-09 1.02E-08 1.01E-08 9.79E-09Ps90%/90% (-KTL) Un-Biased -1.06E-08 -1.02E-08 -1.02E-08 -9.80E-09 -1.06E-08 -1.04E-08 -1.05E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 389: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

389

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=0

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.191. Plot of Input Offset Current @ 5V, VCM=0V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 390: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

390

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.191. Raw data for Input Offset Current @ 5V, VCM=0V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=0V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.86E-09 6.89E-09 6.95E-09 7.23E-09 6.70E-09 6.60E-09 7.37E-09879 -3.83E-09 -4.41E-09 -4.14E-09 -4.37E-09 -2.82E-09 -3.01E-09 -2.99E-09882 -1.30E-09 -1.54E-09 -1.96E-09 -2.18E-09 -2.18E-09 -2.83E-09 -2.16E-09883 3.42E-09 2.95E-09 3.12E-09 3.50E-09 2.78E-09 2.76E-09 2.76E-09885 4.64E-09 4.61E-09 4.51E-09 5.59E-09 5.10E-09 4.28E-09 4.97E-09886 8.67E-10 4.32E-10 6.00E-10 4.90E-10 1.19E-09 7.47E-10 7.70E-10887 -2.15E-09 -2.13E-09 -2.23E-09 -2.32E-09 -1.88E-09 -2.03E-09 -2.01E-09891 3.18E-09 3.05E-09 3.01E-09 2.80E-09 2.98E-09 2.71E-09 2.94E-09892 3.79E-10 1.02E-09 8.05E-10 1.27E-09 7.64E-10 8.92E-10 4.85E-10895 1.63E-09 1.17E-09 1.05E-09 1.81E-09 1.96E-09 2.09E-09 1.73E-09896 2.95E-09 2.92E-09 2.96E-09 2.89E-09 2.94E-09 2.93E-09 2.93E-09

Biased StatisticsAverage Biased 1.96E-09 1.70E-09 1.70E-09 1.95E-09 1.91E-09 1.56E-09 1.99E-09Std Dev Biased 4.40E-09 4.61E-09 4.61E-09 5.01E-09 4.27E-09 4.31E-09 4.49E-09Ps90%/90% (+KTL) Biased 1.40E-08 1.43E-08 1.43E-08 1.57E-08 1.36E-08 1.34E-08 1.43E-08Ps90%/90% (-KTL) Biased -1.01E-08 -1.09E-08 -1.09E-08 -1.18E-08 -9.79E-09 -1.03E-08 -1.03E-08Un-Biased StatisticsAverage Un-Biased 7.80E-10 7.09E-10 6.48E-10 8.11E-10 1.00E-09 8.82E-10 7.81E-10Std Dev Un-Biased 1.95E-09 1.86E-09 1.88E-09 1.94E-09 1.82E-09 1.82E-09 1.83E-09Ps90%/90% (+KTL) Un-Biased 6.13E-09 5.82E-09 5.79E-09 6.13E-09 5.99E-09 5.87E-09 5.81E-09Ps90%/90% (-KTL) Un-Biased -4.57E-09 -4.40E-09 -4.49E-09 -4.51E-09 -3.99E-09 -4.11E-09 -4.24E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 391: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

391

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=0

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.192. Plot of Input Offset Current @ 5V, VCM=0V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 392: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

392

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.192. Raw data for Input Offset Current @ 5V, VCM=0V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=0V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -4.87E-09 -5.20E-09 -3.94E-09 -4.30E-09 -4.36E-09 -4.15E-09 -4.29E-09879 -2.39E-09 -2.94E-09 -2.17E-09 -2.30E-09 -9.59E-10 -1.62E-09 -1.43E-09882 1.60E-09 1.43E-09 1.06E-09 1.11E-09 9.29E-10 1.10E-09 1.20E-09883 -3.26E-09 -3.54E-09 -3.56E-09 -2.15E-09 -2.72E-09 -2.65E-09 -3.12E-09885 7.54E-10 7.14E-10 1.21E-09 2.33E-09 1.15E-09 1.54E-09 1.33E-09886 3.29E-10 1.44E-10 3.22E-10 -1.24E-10 -3.83E-10 -4.88E-10 -3.58E-10887 -3.05E-09 -3.34E-09 -3.47E-09 -3.63E-09 -3.29E-09 -3.04E-09 -3.71E-09891 -2.94E-09 -3.02E-09 -2.88E-09 -3.00E-09 -2.42E-09 -1.88E-09 -2.71E-09892 2.78E-09 2.83E-09 2.94E-09 2.79E-09 2.33E-09 2.87E-09 2.07E-09895 -3.89E-09 -4.17E-09 -3.93E-09 -4.01E-09 -4.07E-09 -4.32E-09 -4.40E-09896 5.65E-09 5.86E-09 5.79E-09 5.79E-09 5.79E-09 5.75E-09 5.77E-09

Biased StatisticsAverage Biased -1.63E-09 -1.91E-09 -1.48E-09 -1.06E-09 -1.19E-09 -1.15E-09 -1.26E-09Std Dev Biased 2.73E-09 2.85E-09 2.48E-09 2.71E-09 2.37E-09 2.44E-09 2.52E-09Ps90%/90% (+KTL) Biased 5.85E-09 5.92E-09 5.31E-09 6.37E-09 5.29E-09 5.52E-09 5.65E-09Ps90%/90% (-KTL) Biased -9.12E-09 -9.73E-09 -8.27E-09 -8.49E-09 -7.68E-09 -7.83E-09 -8.17E-09Un-Biased StatisticsAverage Un-Biased -1.35E-09 -1.51E-09 -1.41E-09 -1.59E-09 -1.56E-09 -1.37E-09 -1.82E-09Std Dev Un-Biased 2.82E-09 2.93E-09 2.94E-09 2.89E-09 2.58E-09 2.76E-09 2.66E-09Ps90%/90% (+KTL) Un-Biased 6.37E-09 6.51E-09 6.67E-09 6.32E-09 5.50E-09 6.21E-09 5.47E-09Ps90%/90% (-KTL) Un-Biased -9.08E-09 -9.54E-09 -9.48E-09 -9.51E-09 -8.63E-09 -8.95E-09 -9.11E-09Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 393: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

393

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=0

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.193. Plot of Positive Input Bias Current @ 5V, VCM=0V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 394: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

394

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.193. Raw data for Positive Input Bias Current @ 5V, VCM=0V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=0V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.08E-07 -3.15E-07 -3.20E-07 -3.24E-07 -3.30E-07 -3.20E-07 -3.14E-07879 -3.19E-07 -3.26E-07 -3.30E-07 -3.34E-07 -3.51E-07 -3.36E-07 -3.30E-07882 -3.33E-07 -3.40E-07 -3.49E-07 -3.54E-07 -3.55E-07 -3.48E-07 -3.38E-07883 -3.31E-07 -3.35E-07 -3.38E-07 -3.45E-07 -3.50E-07 -3.38E-07 -3.32E-07885 -3.15E-07 -3.22E-07 -3.26E-07 -3.35E-07 -3.37E-07 -3.29E-07 -3.22E-07886 -3.06E-07 -3.15E-07 -3.22E-07 -3.27E-07 -3.36E-07 -3.35E-07 -3.20E-07887 -3.25E-07 -3.31E-07 -3.37E-07 -3.47E-07 -3.56E-07 -3.54E-07 -3.34E-07891 -3.33E-07 -3.39E-07 -3.49E-07 -3.53E-07 -3.62E-07 -3.61E-07 -3.49E-07892 -3.30E-07 -3.37E-07 -3.47E-07 -3.51E-07 -3.59E-07 -3.56E-07 -3.39E-07895 -3.26E-07 -3.34E-07 -3.40E-07 -3.50E-07 -3.59E-07 -3.57E-07 -3.37E-07896 -3.49E-07 -3.50E-07 -3.51E-07 -3.49E-07 -3.50E-07 -3.51E-07 -3.48E-07

Biased StatisticsAverage Biased -3.21E-07 -3.28E-07 -3.33E-07 -3.38E-07 -3.45E-07 -3.34E-07 -3.27E-07Std Dev Biased 1.05E-08 1.03E-08 1.12E-08 1.15E-08 1.05E-08 1.03E-08 9.49E-09Ps90%/90% (+KTL) Biased -2.92E-07 -2.99E-07 -3.02E-07 -3.07E-07 -3.16E-07 -3.06E-07 -3.01E-07Ps90%/90% (-KTL) Biased -3.50E-07 -3.56E-07 -3.64E-07 -3.70E-07 -3.74E-07 -3.63E-07 -3.53E-07Un-Biased StatisticsAverage Un-Biased -3.24E-07 -3.31E-07 -3.39E-07 -3.46E-07 -3.54E-07 -3.52E-07 -3.36E-07Std Dev Un-Biased 1.04E-08 9.59E-09 1.10E-08 1.06E-08 1.06E-08 1.04E-08 1.05E-08Ps90%/90% (+KTL) Un-Biased -2.96E-07 -3.05E-07 -3.09E-07 -3.16E-07 -3.25E-07 -3.24E-07 -3.07E-07Ps90%/90% (-KTL) Un-Biased -3.53E-07 -3.57E-07 -3.69E-07 -3.75E-07 -3.83E-07 -3.81E-07 -3.65E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 395: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

395

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=0

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.194. Plot of Positive Input Bias Current @ 5V, VCM=0V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 396: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

396

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.194. Raw data for Positive Input Bias Current @ 5V, VCM=0V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=0V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.16E-07 -3.23E-07 -3.28E-07 -3.31E-07 -3.37E-07 -3.29E-07 -3.22E-07879 -3.30E-07 -3.34E-07 -3.35E-07 -3.36E-07 -3.50E-07 -3.45E-07 -3.37E-07882 -3.14E-07 -3.21E-07 -3.26E-07 -3.30E-07 -3.36E-07 -3.27E-07 -3.20E-07883 -3.22E-07 -3.27E-07 -3.30E-07 -3.33E-07 -3.36E-07 -3.27E-07 -3.22E-07885 -3.20E-07 -3.25E-07 -3.29E-07 -3.37E-07 -3.38E-07 -3.29E-07 -3.23E-07886 -3.05E-07 -3.13E-07 -3.19E-07 -3.24E-07 -3.32E-07 -3.31E-07 -3.17E-07887 -3.31E-07 -3.35E-07 -3.38E-07 -3.41E-07 -3.51E-07 -3.51E-07 -3.37E-07891 -3.15E-07 -3.21E-07 -3.27E-07 -3.33E-07 -3.41E-07 -3.40E-07 -3.25E-07892 -3.15E-07 -3.23E-07 -3.28E-07 -3.32E-07 -3.40E-07 -3.39E-07 -3.25E-07895 -3.06E-07 -3.13E-07 -3.19E-07 -3.25E-07 -3.34E-07 -3.32E-07 -3.18E-07896 -3.26E-07 -3.28E-07 -3.27E-07 -3.26E-07 -3.27E-07 -3.27E-07 -3.26E-07

Biased StatisticsAverage Biased -3.20E-07 -3.26E-07 -3.29E-07 -3.33E-07 -3.39E-07 -3.31E-07 -3.25E-07Std Dev Biased 6.15E-09 4.94E-09 3.44E-09 3.06E-09 6.08E-09 7.52E-09 6.86E-09Ps90%/90% (+KTL) Biased -3.04E-07 -3.13E-07 -3.20E-07 -3.25E-07 -3.23E-07 -3.11E-07 -3.06E-07Ps90%/90% (-KTL) Biased -3.37E-07 -3.40E-07 -3.39E-07 -3.42E-07 -3.56E-07 -3.52E-07 -3.44E-07Un-Biased StatisticsAverage Un-Biased -3.14E-07 -3.21E-07 -3.26E-07 -3.31E-07 -3.40E-07 -3.39E-07 -3.24E-07Std Dev Un-Biased 1.04E-08 8.99E-09 7.77E-09 6.98E-09 7.68E-09 8.24E-09 7.96E-09Ps90%/90% (+KTL) Un-Biased -2.86E-07 -2.96E-07 -3.05E-07 -3.12E-07 -3.19E-07 -3.16E-07 -3.03E-07Ps90%/90% (-KTL) Un-Biased -3.43E-07 -3.46E-07 -3.48E-07 -3.50E-07 -3.61E-07 -3.61E-07 -3.46E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 397: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

397

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=0

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.195. Plot of Positive Input Bias Current @ 5V, VCM=0V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 398: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

398

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.195. Raw data for Positive Input Bias Current @ 5V, VCM=0V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=0V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.12E-07 -3.19E-07 -3.25E-07 -3.29E-07 -3.35E-07 -3.25E-07 -3.18E-07879 -3.24E-07 -3.28E-07 -3.29E-07 -3.30E-07 -3.40E-07 -3.36E-07 -3.31E-07882 -3.15E-07 -3.22E-07 -3.27E-07 -3.31E-07 -3.38E-07 -3.29E-07 -3.22E-07883 -3.16E-07 -3.22E-07 -3.25E-07 -3.28E-07 -3.32E-07 -3.24E-07 -3.18E-07885 -3.22E-07 -3.27E-07 -3.32E-07 -3.40E-07 -3.40E-07 -3.32E-07 -3.26E-07886 -3.00E-07 -3.08E-07 -3.14E-07 -3.19E-07 -3.28E-07 -3.26E-07 -3.12E-07887 -3.27E-07 -3.31E-07 -3.35E-07 -3.38E-07 -3.47E-07 -3.46E-07 -3.33E-07891 -3.09E-07 -3.15E-07 -3.21E-07 -3.27E-07 -3.36E-07 -3.34E-07 -3.20E-07892 -3.09E-07 -3.17E-07 -3.22E-07 -3.26E-07 -3.35E-07 -3.34E-07 -3.19E-07895 -3.03E-07 -3.11E-07 -3.17E-07 -3.22E-07 -3.31E-07 -3.29E-07 -3.15E-07896 -3.25E-07 -3.26E-07 -3.26E-07 -3.25E-07 -3.25E-07 -3.26E-07 -3.25E-07

Biased StatisticsAverage Biased -3.18E-07 -3.24E-07 -3.27E-07 -3.32E-07 -3.37E-07 -3.29E-07 -3.23E-07Std Dev Biased 4.87E-09 3.69E-09 2.92E-09 4.81E-09 3.45E-09 4.83E-09 5.49E-09Ps90%/90% (+KTL) Biased -3.05E-07 -3.14E-07 -3.19E-07 -3.18E-07 -3.28E-07 -3.16E-07 -3.08E-07Ps90%/90% (-KTL) Biased -3.31E-07 -3.34E-07 -3.35E-07 -3.45E-07 -3.47E-07 -3.43E-07 -3.38E-07Un-Biased StatisticsAverage Un-Biased -3.10E-07 -3.16E-07 -3.22E-07 -3.26E-07 -3.35E-07 -3.34E-07 -3.20E-07Std Dev Un-Biased 1.04E-08 8.78E-09 7.86E-09 7.14E-09 7.30E-09 7.54E-09 7.97E-09Ps90%/90% (+KTL) Un-Biased -2.81E-07 -2.92E-07 -3.00E-07 -3.07E-07 -3.15E-07 -3.13E-07 -2.98E-07Ps90%/90% (-KTL) Un-Biased -3.38E-07 -3.40E-07 -3.43E-07 -3.46E-07 -3.55E-07 -3.55E-07 -3.42E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 399: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

399

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=0

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.196. Plot of Positive Input Bias Current @ 5V, VCM=0V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 400: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

400

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.196. Raw data for Positive Input Bias Current @ 5V, VCM=0V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=0V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.14E-07 -3.21E-07 -3.26E-07 -3.30E-07 -3.35E-07 -3.25E-07 -3.19E-07879 -3.20E-07 -3.28E-07 -3.32E-07 -3.35E-07 -3.51E-07 -3.38E-07 -3.31E-07882 -3.30E-07 -3.37E-07 -3.41E-07 -3.49E-07 -3.52E-07 -3.41E-07 -3.35E-07883 -3.31E-07 -3.36E-07 -3.39E-07 -3.46E-07 -3.49E-07 -3.38E-07 -3.32E-07885 -3.12E-07 -3.18E-07 -3.23E-07 -3.31E-07 -3.34E-07 -3.25E-07 -3.18E-07886 -3.13E-07 -3.21E-07 -3.28E-07 -3.33E-07 -3.50E-07 -3.41E-07 -3.26E-07887 -3.31E-07 -3.37E-07 -3.48E-07 -3.53E-07 -3.63E-07 -3.59E-07 -3.41E-07891 -3.32E-07 -3.37E-07 -3.47E-07 -3.52E-07 -3.58E-07 -3.59E-07 -3.39E-07892 -3.25E-07 -3.32E-07 -3.36E-07 -3.40E-07 -3.53E-07 -3.51E-07 -3.34E-07895 -3.26E-07 -3.34E-07 -3.40E-07 -3.50E-07 -3.58E-07 -3.57E-07 -3.38E-07896 -3.51E-07 -3.57E-07 -3.59E-07 -3.55E-07 -3.53E-07 -3.58E-07 -3.55E-07

Biased StatisticsAverage Biased -3.21E-07 -3.28E-07 -3.32E-07 -3.38E-07 -3.44E-07 -3.33E-07 -3.27E-07Std Dev Biased 8.62E-09 8.39E-09 7.83E-09 9.01E-09 8.85E-09 7.71E-09 7.68E-09Ps90%/90% (+KTL) Biased -2.98E-07 -3.05E-07 -3.11E-07 -3.14E-07 -3.20E-07 -3.12E-07 -3.06E-07Ps90%/90% (-KTL) Biased -3.45E-07 -3.51E-07 -3.54E-07 -3.63E-07 -3.68E-07 -3.54E-07 -3.48E-07Un-Biased StatisticsAverage Un-Biased -3.25E-07 -3.32E-07 -3.40E-07 -3.46E-07 -3.56E-07 -3.53E-07 -3.35E-07Std Dev Un-Biased 7.56E-09 6.71E-09 8.38E-09 8.70E-09 5.11E-09 7.67E-09 5.85E-09Ps90%/90% (+KTL) Un-Biased -3.05E-07 -3.14E-07 -3.17E-07 -3.22E-07 -3.42E-07 -3.32E-07 -3.19E-07Ps90%/90% (-KTL) Un-Biased -3.46E-07 -3.51E-07 -3.63E-07 -3.70E-07 -3.70E-07 -3.74E-07 -3.52E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 401: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

401

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=0V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.197. Plot of Negative Input Bias Current @ 5V, VCM=0V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 402: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

402

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.197. Raw data for Negative Input Bias Current @ 5V, VCM=0V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=0V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.09E-07 -3.16E-07 -3.22E-07 -3.26E-07 -3.31E-07 -3.21E-07 -3.14E-07879 -3.20E-07 -3.27E-07 -3.32E-07 -3.35E-07 -3.54E-07 -3.39E-07 -3.31E-07882 -3.29E-07 -3.36E-07 -3.40E-07 -3.49E-07 -3.54E-07 -3.44E-07 -3.34E-07883 -3.28E-07 -3.34E-07 -3.37E-07 -3.40E-07 -3.50E-07 -3.36E-07 -3.30E-07885 -3.13E-07 -3.19E-07 -3.24E-07 -3.34E-07 -3.36E-07 -3.26E-07 -3.20E-07886 -3.11E-07 -3.19E-07 -3.25E-07 -3.31E-07 -3.40E-07 -3.38E-07 -3.24E-07887 -3.27E-07 -3.34E-07 -3.40E-07 -3.50E-07 -3.60E-07 -3.57E-07 -3.37E-07891 -3.33E-07 -3.38E-07 -3.48E-07 -3.55E-07 -3.62E-07 -3.61E-07 -3.40E-07892 -3.28E-07 -3.35E-07 -3.40E-07 -3.50E-07 -3.56E-07 -3.55E-07 -3.37E-07895 -3.27E-07 -3.35E-07 -3.46E-07 -3.53E-07 -3.62E-07 -3.61E-07 -3.39E-07896 -3.49E-07 -3.52E-07 -3.51E-07 -3.52E-07 -3.52E-07 -3.52E-07 -3.51E-07

Biased StatisticsAverage Biased -3.20E-07 -3.26E-07 -3.31E-07 -3.37E-07 -3.45E-07 -3.33E-07 -3.26E-07Std Dev Biased 8.97E-09 8.92E-09 7.92E-09 8.64E-09 1.09E-08 9.48E-09 8.34E-09Ps90%/90% (+KTL) Biased -2.95E-07 -3.02E-07 -3.09E-07 -3.13E-07 -3.15E-07 -3.07E-07 -3.03E-07Ps90%/90% (-KTL) Biased -3.44E-07 -3.51E-07 -3.53E-07 -3.60E-07 -3.75E-07 -3.59E-07 -3.49E-07Un-Biased StatisticsAverage Un-Biased -3.25E-07 -3.32E-07 -3.40E-07 -3.48E-07 -3.56E-07 -3.54E-07 -3.35E-07Std Dev Un-Biased 8.10E-09 7.47E-09 8.83E-09 9.65E-09 9.29E-09 9.22E-09 6.64E-09Ps90%/90% (+KTL) Un-Biased -3.03E-07 -3.12E-07 -3.16E-07 -3.21E-07 -3.31E-07 -3.29E-07 -3.17E-07Ps90%/90% (-KTL) Un-Biased -3.47E-07 -3.53E-07 -3.64E-07 -3.74E-07 -3.81E-07 -3.80E-07 -3.54E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 403: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

403

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=0V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.198. Plot of Negative Input Bias Current @ 5V, VCM=0V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 404: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

404

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.198. Raw data for Negative Input Bias Current @ 5V, VCM=0V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=0V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.15E-07 -3.22E-07 -3.27E-07 -3.33E-07 -3.46E-07 -3.28E-07 -3.22E-07879 -3.24E-07 -3.27E-07 -3.29E-07 -3.30E-07 -3.45E-07 -3.37E-07 -3.32E-07882 -3.11E-07 -3.18E-07 -3.22E-07 -3.26E-07 -3.32E-07 -3.23E-07 -3.17E-07883 -3.22E-07 -3.26E-07 -3.30E-07 -3.33E-07 -3.37E-07 -3.34E-07 -3.22E-07885 -3.21E-07 -3.26E-07 -3.31E-07 -3.40E-07 -3.39E-07 -3.31E-07 -3.25E-07886 -3.05E-07 -3.13E-07 -3.19E-07 -3.24E-07 -3.33E-07 -3.32E-07 -3.17E-07887 -3.24E-07 -3.28E-07 -3.32E-07 -3.35E-07 -3.40E-07 -3.40E-07 -3.30E-07891 -3.16E-07 -3.22E-07 -3.27E-07 -3.33E-07 -3.47E-07 -3.41E-07 -3.26E-07892 -3.17E-07 -3.25E-07 -3.30E-07 -3.35E-07 -3.50E-07 -3.41E-07 -3.27E-07895 -3.09E-07 -3.16E-07 -3.22E-07 -3.27E-07 -3.36E-07 -3.35E-07 -3.20E-07896 -3.28E-07 -3.30E-07 -3.30E-07 -3.29E-07 -3.29E-07 -3.30E-07 -3.28E-07

Biased StatisticsAverage Biased -3.19E-07 -3.24E-07 -3.28E-07 -3.32E-07 -3.40E-07 -3.31E-07 -3.23E-07Std Dev Biased 5.37E-09 4.12E-09 3.56E-09 5.12E-09 5.62E-09 5.41E-09 5.45E-09Ps90%/90% (+KTL) Biased -3.04E-07 -3.13E-07 -3.18E-07 -3.18E-07 -3.24E-07 -3.16E-07 -3.08E-07Ps90%/90% (-KTL) Biased -3.33E-07 -3.35E-07 -3.37E-07 -3.46E-07 -3.55E-07 -3.45E-07 -3.38E-07Un-Biased StatisticsAverage Un-Biased -3.14E-07 -3.21E-07 -3.26E-07 -3.31E-07 -3.41E-07 -3.38E-07 -3.24E-07Std Dev Un-Biased 7.59E-09 6.15E-09 5.45E-09 4.87E-09 7.19E-09 4.25E-09 5.41E-09Ps90%/90% (+KTL) Un-Biased -2.93E-07 -3.04E-07 -3.11E-07 -3.17E-07 -3.22E-07 -3.26E-07 -3.09E-07Ps90%/90% (-KTL) Un-Biased -3.35E-07 -3.38E-07 -3.41E-07 -3.44E-07 -3.61E-07 -3.50E-07 -3.39E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 405: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

405

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=0V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.199. Plot of Negative Input Bias Current @ 5V, VCM=0V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 406: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

406

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.199. Raw data for Negative Input Bias Current @ 5V, VCM=0V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=0V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.19E-07 -3.26E-07 -3.32E-07 -3.36E-07 -3.46E-07 -3.32E-07 -3.26E-07879 -3.20E-07 -3.23E-07 -3.24E-07 -3.26E-07 -3.38E-07 -3.33E-07 -3.28E-07882 -3.13E-07 -3.21E-07 -3.25E-07 -3.29E-07 -3.35E-07 -3.26E-07 -3.20E-07883 -3.20E-07 -3.25E-07 -3.28E-07 -3.32E-07 -3.35E-07 -3.27E-07 -3.21E-07885 -3.27E-07 -3.32E-07 -3.36E-07 -3.52E-07 -3.51E-07 -3.37E-07 -3.31E-07886 -3.02E-07 -3.09E-07 -3.15E-07 -3.20E-07 -3.29E-07 -3.27E-07 -3.13E-07887 -3.25E-07 -3.29E-07 -3.32E-07 -3.36E-07 -3.47E-07 -3.48E-07 -3.31E-07891 -3.13E-07 -3.19E-07 -3.24E-07 -3.30E-07 -3.39E-07 -3.38E-07 -3.23E-07892 -3.09E-07 -3.18E-07 -3.23E-07 -3.28E-07 -3.36E-07 -3.35E-07 -3.20E-07895 -3.05E-07 -3.12E-07 -3.18E-07 -3.23E-07 -3.33E-07 -3.31E-07 -3.17E-07896 -3.28E-07 -3.29E-07 -3.29E-07 -3.28E-07 -3.28E-07 -3.29E-07 -3.28E-07

Biased StatisticsAverage Biased -3.20E-07 -3.25E-07 -3.29E-07 -3.35E-07 -3.41E-07 -3.31E-07 -3.25E-07Std Dev Biased 4.81E-09 4.10E-09 5.10E-09 1.01E-08 7.06E-09 4.44E-09 4.77E-09Ps90%/90% (+KTL) Biased -3.07E-07 -3.14E-07 -3.15E-07 -3.07E-07 -3.22E-07 -3.19E-07 -3.12E-07Ps90%/90% (-KTL) Biased -3.33E-07 -3.37E-07 -3.43E-07 -3.63E-07 -3.60E-07 -3.43E-07 -3.38E-07Un-Biased StatisticsAverage Un-Biased -3.11E-07 -3.17E-07 -3.23E-07 -3.27E-07 -3.37E-07 -3.36E-07 -3.21E-07Std Dev Un-Biased 9.17E-09 7.68E-09 6.74E-09 6.00E-09 6.97E-09 8.02E-09 6.80E-09Ps90%/90% (+KTL) Un-Biased -2.86E-07 -2.96E-07 -3.04E-07 -3.11E-07 -3.17E-07 -3.14E-07 -3.02E-07Ps90%/90% (-KTL) Un-Biased -3.36E-07 -3.38E-07 -3.41E-07 -3.44E-07 -3.56E-07 -3.58E-07 -3.39E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 407: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

407

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=0V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.200. Plot of Negative Input Bias Current @ 5V, VCM=0V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 408: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

408

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.200. Raw data for Negative Input Bias Current @ 5V, VCM=0V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=0V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -3.09E-07 -3.16E-07 -3.22E-07 -3.26E-07 -3.31E-07 -3.22E-07 -3.15E-07879 -3.18E-07 -3.25E-07 -3.30E-07 -3.33E-07 -3.51E-07 -3.36E-07 -3.29E-07882 -3.31E-07 -3.39E-07 -3.48E-07 -3.52E-07 -3.54E-07 -3.46E-07 -3.36E-07883 -3.28E-07 -3.32E-07 -3.36E-07 -3.40E-07 -3.47E-07 -3.35E-07 -3.29E-07885 -3.13E-07 -3.19E-07 -3.25E-07 -3.34E-07 -3.35E-07 -3.26E-07 -3.20E-07886 -3.14E-07 -3.21E-07 -3.28E-07 -3.33E-07 -3.47E-07 -3.44E-07 -3.26E-07887 -3.28E-07 -3.34E-07 -3.40E-07 -3.51E-07 -3.60E-07 -3.58E-07 -3.37E-07891 -3.29E-07 -3.34E-07 -3.40E-07 -3.51E-07 -3.58E-07 -3.57E-07 -3.37E-07892 -3.28E-07 -3.35E-07 -3.39E-07 -3.48E-07 -3.56E-07 -3.55E-07 -3.36E-07895 -3.23E-07 -3.30E-07 -3.36E-07 -3.47E-07 -3.56E-07 -3.52E-07 -3.34E-07896 -3.62E-07 -3.62E-07 -3.64E-07 -3.60E-07 -3.59E-07 -3.68E-07 -3.65E-07

Biased StatisticsAverage Biased -3.20E-07 -3.26E-07 -3.32E-07 -3.37E-07 -3.44E-07 -3.33E-07 -3.26E-07Std Dev Biased 9.28E-09 9.25E-09 1.02E-08 9.81E-09 1.00E-08 9.56E-09 8.34E-09Ps90%/90% (+KTL) Biased -2.95E-07 -3.01E-07 -3.04E-07 -3.10E-07 -3.16E-07 -3.07E-07 -3.03E-07Ps90%/90% (-KTL) Biased -3.45E-07 -3.52E-07 -3.60E-07 -3.64E-07 -3.71E-07 -3.59E-07 -3.49E-07Un-Biased StatisticsAverage Un-Biased -3.24E-07 -3.31E-07 -3.37E-07 -3.46E-07 -3.55E-07 -3.53E-07 -3.34E-07Std Dev Un-Biased 6.44E-09 5.77E-09 5.15E-09 7.52E-09 4.95E-09 5.65E-09 4.66E-09Ps90%/90% (+KTL) Un-Biased -3.07E-07 -3.15E-07 -3.23E-07 -3.26E-07 -3.42E-07 -3.38E-07 -3.21E-07Ps90%/90% (-KTL) Un-Biased -3.42E-07 -3.47E-07 -3.51E-07 -3.67E-07 -3.69E-07 -3.69E-07 -3.47E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 409: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

409

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=5

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.201. Plot of Input Offset Voltage @ 5V, VCM=5V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 410: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

410

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.201. Raw data for Input Offset Voltage @ 5V, VCM=5V #1 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.84E-05 3.18E-05 4.07E-05 4.63E-05 4.80E-05 4.05E-05 3.88E-05879 2.52E-04 2.22E-04 2.36E-04 2.28E-04 2.31E-04 2.21E-04 2.31E-04882 3.38E-04 3.33E-04 3.39E-04 3.40E-04 3.40E-04 3.37E-04 3.46E-04883 3.27E-04 3.12E-04 3.21E-04 3.34E-04 3.21E-04 3.17E-04 3.18E-04885 7.81E-05 6.20E-05 6.84E-05 7.09E-05 6.61E-05 6.47E-05 5.13E-05886 4.74E-05 3.22E-05 2.96E-05 2.56E-05 1.95E-05 1.79E-05 1.37E-05887 3.96E-04 3.86E-04 3.86E-04 3.85E-04 3.77E-04 3.75E-04 3.71E-04891 3.04E-04 2.92E-04 2.87E-04 2.84E-04 2.81E-04 2.77E-04 2.68E-04892 -1.21E-04 -1.31E-04 -1.32E-04 -1.38E-04 -1.38E-04 -1.39E-04 -1.39E-04895 1.13E-04 9.63E-05 9.12E-05 8.83E-05 7.65E-05 7.31E-05 9.47E-05896 -7.21E-05 -7.45E-05 -7.43E-05 -7.36E-05 -7.36E-05 -7.44E-05 -7.27E-05

Biased StatisticsAverage Biased 2.09E-04 1.92E-04 2.01E-04 2.04E-04 2.01E-04 1.96E-04 1.97E-04Std Dev Biased 1.37E-04 1.39E-04 1.40E-04 1.40E-04 1.38E-04 1.38E-04 1.45E-04Ps90%/90% (+KTL) Biased 5.85E-04 5.74E-04 5.84E-04 5.89E-04 5.80E-04 5.75E-04 5.96E-04Ps90%/90% (-KTL) Biased -1.67E-04 -1.90E-04 -1.82E-04 -1.81E-04 -1.77E-04 -1.83E-04 -2.01E-04Un-Biased StatisticsAverage Un-Biased 1.48E-04 1.35E-04 1.32E-04 1.29E-04 1.23E-04 1.21E-04 1.22E-04Std Dev Un-Biased 2.06E-04 2.06E-04 2.06E-04 2.08E-04 2.06E-04 2.06E-04 2.02E-04Ps90%/90% (+KTL) Un-Biased 7.12E-04 7.01E-04 6.98E-04 6.99E-04 6.89E-04 6.86E-04 6.76E-04Ps90%/90% (-KTL) Un-Biased -4.16E-04 -4.31E-04 -4.34E-04 -4.41E-04 -4.43E-04 -4.44E-04 -4.33E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 411: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

411

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=5

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.202. Plot of Input Offset Voltage @ 5V, VCM=5V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 412: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

412

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.202. Raw data for Input Offset Voltage @ 5V, VCM=5V #2 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.44E-04 2.26E-04 2.29E-04 2.57E-04 2.85E-04 2.59E-04 2.49E-04879 1.17E-04 1.20E-04 1.41E-04 1.34E-04 1.36E-04 1.33E-04 1.41E-04882 2.74E-04 2.65E-04 2.67E-04 2.70E-04 2.70E-04 2.67E-04 2.70E-04883 7.70E-05 6.36E-05 7.75E-05 9.70E-05 9.06E-05 1.07E-04 8.50E-05885 1.49E-04 1.49E-04 1.78E-04 1.69E-04 1.71E-04 1.53E-04 1.60E-04886 2.07E-04 1.92E-04 1.89E-04 1.87E-04 1.83E-04 1.82E-04 1.68E-04887 1.81E-04 1.93E-04 1.89E-04 1.88E-04 1.88E-04 1.82E-04 1.66E-04891 3.06E-04 3.05E-04 3.07E-04 3.05E-04 3.07E-04 3.00E-04 2.95E-04892 5.17E-05 4.27E-05 4.22E-05 4.04E-05 3.80E-05 2.85E-05 2.73E-05895 1.05E-04 9.29E-05 9.18E-05 9.03E-05 8.82E-05 8.29E-05 8.22E-05896 4.33E-05 4.21E-05 4.17E-05 4.27E-05 4.26E-05 4.17E-05 4.24E-05

Biased StatisticsAverage Biased 1.72E-04 1.65E-04 1.78E-04 1.85E-04 1.91E-04 1.83E-04 1.81E-04Std Dev Biased 8.39E-05 8.12E-05 7.40E-05 7.58E-05 8.46E-05 7.43E-05 7.71E-05Ps90%/90% (+KTL) Biased 4.02E-04 3.88E-04 3.81E-04 3.93E-04 4.22E-04 3.87E-04 3.93E-04Ps90%/90% (-KTL) Biased -5.78E-05 -5.78E-05 -2.45E-05 -2.28E-05 -4.13E-05 -2.01E-05 -3.03E-05Un-Biased StatisticsAverage Un-Biased 1.70E-04 1.65E-04 1.64E-04 1.62E-04 1.61E-04 1.55E-04 1.48E-04Std Dev Un-Biased 9.76E-05 1.02E-04 1.02E-04 1.02E-04 1.04E-04 1.04E-04 1.01E-04Ps90%/90% (+KTL) Un-Biased 4.38E-04 4.44E-04 4.44E-04 4.42E-04 4.45E-04 4.41E-04 4.26E-04Ps90%/90% (-KTL) Un-Biased -9.76E-05 -1.13E-04 -1.16E-04 -1.18E-04 -1.23E-04 -1.31E-04 -1.30E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 413: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

413

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=5

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.203. Plot of Input Offset Voltage @ 5V, VCM=5V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 414: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

414

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.203. Raw data for Input Offset Voltage @ 5V, VCM=5V #3 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -1.12E-04 -1.33E-04 -1.25E-04 -1.17E-04 -1.15E-04 -1.21E-04 -1.21E-04879 4.33E-04 4.00E-04 4.22E-04 4.12E-04 4.18E-04 4.08E-04 4.29E-04882 1.10E-04 8.97E-05 9.28E-05 9.26E-05 8.74E-05 8.47E-05 8.44E-05883 3.30E-04 3.05E-04 3.07E-04 3.31E-04 3.11E-04 3.10E-04 3.08E-04885 7.48E-05 5.22E-05 5.36E-05 6.65E-05 4.74E-05 4.27E-05 5.42E-05886 -2.81E-05 -4.08E-05 -4.32E-05 -4.65E-05 -5.12E-05 -5.09E-05 -5.52E-05887 -1.49E-04 -1.48E-04 -1.50E-04 -1.54E-04 -1.60E-04 -1.64E-04 -1.64E-04891 3.32E-04 3.24E-04 3.24E-04 3.22E-04 3.21E-04 3.16E-04 3.14E-04892 2.73E-04 2.61E-04 2.60E-04 2.63E-04 2.66E-04 2.59E-04 2.53E-04895 9.87E-05 7.96E-05 7.77E-05 7.38E-05 7.20E-05 6.83E-05 6.82E-05896 1.67E-04 1.61E-04 1.64E-04 1.66E-04 1.65E-04 1.64E-04 1.66E-04

Biased StatisticsAverage Biased 1.67E-04 1.43E-04 1.50E-04 1.57E-04 1.50E-04 1.45E-04 1.51E-04Std Dev Biased 2.16E-04 2.12E-04 2.16E-04 2.14E-04 2.14E-04 2.13E-04 2.18E-04Ps90%/90% (+KTL) Biased 7.59E-04 7.23E-04 7.43E-04 7.43E-04 7.36E-04 7.29E-04 7.48E-04Ps90%/90% (-KTL) Biased -4.25E-04 -4.38E-04 -4.42E-04 -4.29E-04 -4.36E-04 -4.39E-04 -4.46E-04Un-Biased StatisticsAverage Un-Biased 1.05E-04 9.51E-05 9.36E-05 9.18E-05 8.97E-05 8.58E-05 8.32E-05Std Dev Un-Biased 2.01E-04 1.99E-04 1.99E-04 2.01E-04 2.04E-04 2.03E-04 2.02E-04Ps90%/90% (+KTL) Un-Biased 6.58E-04 6.40E-04 6.40E-04 6.43E-04 6.50E-04 6.41E-04 6.36E-04Ps90%/90% (-KTL) Un-Biased -4.47E-04 -4.49E-04 -4.53E-04 -4.60E-04 -4.71E-04 -4.70E-04 -4.70E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 415: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

415

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.50E-03

-1.00E-03

-5.00E-04

0.00E+00

5.00E-04

1.00E-03

1.50E-03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et V

olta

ge @

5V,

VC

M=5

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.204. Plot of Input Offset Voltage @ 5V, VCM=5V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 416: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

416

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.204. Raw data for Input Offset Voltage @ 5V, VCM=5V #4 (V) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Voltage @ 5V, VCM=5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.34E-04 1.16E-04 1.26E-04 1.32E-04 1.41E-04 1.35E-04 1.29E-04879 1.75E-04 1.51E-04 1.69E-04 1.58E-04 1.66E-04 1.61E-04 1.54E-04882 2.44E-05 1.05E-05 2.00E-05 2.54E-05 2.86E-05 2.41E-05 3.40E-05883 1.82E-05 7.40E-06 1.65E-05 4.18E-05 2.64E-05 2.03E-05 2.30E-05885 1.01E-04 7.86E-05 8.44E-05 9.45E-05 8.51E-05 7.96E-05 7.32E-05886 1.76E-04 1.62E-04 1.55E-04 1.55E-04 1.56E-04 1.49E-04 1.44E-04887 -2.30E-05 -3.71E-05 -3.61E-05 -3.90E-05 -4.36E-05 -4.65E-05 -4.15E-05891 1.48E-04 1.36E-04 1.37E-04 1.40E-04 1.42E-04 1.37E-04 1.23E-04892 8.41E-05 8.92E-05 8.89E-05 9.76E-05 9.61E-05 9.28E-05 8.80E-05895 3.84E-04 3.69E-04 3.66E-04 3.62E-04 3.53E-04 3.46E-04 3.45E-04896 7.08E-05 7.41E-05 6.90E-05 7.44E-05 7.02E-05 7.01E-05 7.32E-05

Biased StatisticsAverage Biased 9.06E-05 7.28E-05 8.33E-05 9.03E-05 8.94E-05 8.40E-05 8.26E-05Std Dev Biased 6.85E-05 6.37E-05 6.65E-05 5.68E-05 6.37E-05 6.36E-05 5.75E-05Ps90%/90% (+KTL) Biased 2.78E-04 2.47E-04 2.66E-04 2.46E-04 2.64E-04 2.59E-04 2.40E-04Ps90%/90% (-KTL) Biased -9.72E-05 -1.02E-04 -9.92E-05 -6.54E-05 -8.53E-05 -9.04E-05 -7.51E-05Un-Biased StatisticsAverage Un-Biased 1.54E-04 1.44E-04 1.42E-04 1.43E-04 1.41E-04 1.36E-04 1.32E-04Std Dev Un-Biased 1.50E-04 1.47E-04 1.46E-04 1.44E-04 1.43E-04 1.41E-04 1.39E-04Ps90%/90% (+KTL) Un-Biased 5.65E-04 5.48E-04 5.42E-04 5.39E-04 5.32E-04 5.22E-04 5.13E-04Ps90%/90% (-KTL) Un-Biased -2.57E-04 -2.60E-04 -2.58E-04 -2.53E-04 -2.50E-04 -2.51E-04 -2.50E-04Specification MIN -8.00E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04 -9.50E-04Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 8.00E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04 9.50E-04Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 417: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

417

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=5

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.205. Plot of Input Offset Current @ 5V, VCM=5V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 418: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

418

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.205. Raw data for Input Offset Current @ 5V, VCM=5V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=5V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.05E-09 3.67E-10 1.39E-09 2.01E-09 2.53E-09 4.62E-10 1.61E-08879 6.66E-09 8.57E-09 8.67E-09 8.81E-09 1.58E-08 1.31E-08 2.73E-08882 3.73E-09 5.74E-09 5.18E-09 5.85E-09 6.67E-09 4.36E-09 1.85E-08883 -8.60E-10 -1.18E-09 -1.51E-10 1.28E-10 1.44E-09 -1.17E-10 1.50E-08885 6.05E-09 5.50E-09 3.19E-09 9.24E-09 7.66E-09 3.69E-09 2.32E-08886 1.80E-09 1.71E-09 8.85E-10 7.16E-10 4.75E-10 4.93E-10 1.45E-09887 1.61E-08 1.64E-08 1.73E-08 1.68E-08 1.63E-08 1.63E-08 1.46E-08891 2.51E-09 3.16E-09 4.17E-09 4.09E-09 6.06E-09 4.58E-09 2.60E-09892 2.06E-09 1.75E-09 1.59E-09 3.01E-09 3.76E-09 3.79E-09 6.70E-10895 8.85E-09 9.49E-09 9.08E-09 8.69E-09 9.02E-09 8.41E-09 7.36E-09896 1.60E-11 2.20E-11 9.10E-11 4.40E-11 9.50E-11 7.00E-12 1.29E-10

Biased StatisticsAverage Biased 3.32E-09 3.80E-09 3.66E-09 5.21E-09 6.83E-09 4.31E-09 2.00E-08Std Dev Biased 3.22E-09 4.06E-09 3.44E-09 4.05E-09 5.69E-09 5.31E-09 5.16E-09Ps90%/90% (+KTL) Biased 1.21E-08 1.49E-08 1.31E-08 1.63E-08 2.24E-08 1.89E-08 3.42E-08Ps90%/90% (-KTL) Biased -5.50E-09 -7.33E-09 -5.77E-09 -5.91E-09 -8.77E-09 -1.03E-08 5.89E-09Un-Biased StatisticsAverage Un-Biased 6.27E-09 6.51E-09 6.61E-09 6.67E-09 7.12E-09 6.72E-09 5.32E-09Std Dev Un-Biased 6.24E-09 6.41E-09 6.79E-09 6.38E-09 6.00E-09 6.06E-09 5.78E-09Ps90%/90% (+KTL) Un-Biased 2.34E-08 2.41E-08 2.52E-08 2.42E-08 2.36E-08 2.33E-08 2.12E-08Ps90%/90% (-KTL) Un-Biased -1.08E-08 -1.11E-08 -1.20E-08 -1.08E-08 -9.34E-09 -9.90E-09 -1.05E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 419: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

419

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=5

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.206. Plot of Input Offset Current @ 5V, VCM=5V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 420: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

420

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.206. Raw data for Input Offset Current @ 5V, VCM=5V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=5V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.94E-09 -4.27E-09 -3.40E-09 3.28E-10 2.11E-09 4.08E-09 2.33E-08879 9.81E-10 4.18E-09 7.39E-09 7.47E-09 1.51E-08 1.17E-08 2.59E-08882 5.24E-10 2.45E-09 3.63E-09 2.36E-09 2.09E-09 1.93E-09 1.80E-08883 1.83E-09 2.95E-09 2.78E-09 6.39E-09 6.41E-09 2.63E-10 1.93E-08885 2.08E-09 4.13E-09 8.24E-09 1.13E-08 8.37E-09 5.24E-09 2.20E-08886 -1.27E-08 -1.17E-08 -1.15E-08 -1.17E-08 -1.07E-08 -1.14E-08 -1.29E-08887 1.62E-08 1.68E-08 1.74E-08 1.62E-08 1.68E-08 1.57E-08 1.52E-08891 -2.05E-09 -6.51E-10 -3.20E-10 6.30E-10 1.25E-09 4.16E-10 -1.13E-09892 -4.78E-09 -4.07E-09 -3.35E-09 -2.51E-09 -2.14E-09 -3.53E-09 -5.27E-09895 5.56E-09 5.84E-09 6.19E-09 5.89E-09 6.49E-09 3.71E-09 4.00E-09896 -8.63E-09 -9.14E-09 -8.62E-09 -8.66E-09 -8.79E-09 -8.83E-09 -8.99E-09

Biased StatisticsAverage Biased 4.96E-10 1.89E-09 3.73E-09 5.57E-09 6.80E-09 4.65E-09 2.17E-08Std Dev Biased 2.02E-09 3.52E-09 4.62E-09 4.33E-09 5.36E-09 4.40E-09 3.15E-09Ps90%/90% (+KTL) Biased 6.03E-09 1.15E-08 1.64E-08 1.74E-08 2.15E-08 1.67E-08 3.03E-08Ps90%/90% (-KTL) Biased -5.04E-09 -7.77E-09 -8.95E-09 -6.29E-09 -7.90E-09 -7.42E-09 1.31E-08Un-Biased StatisticsAverage Un-Biased 4.42E-10 1.25E-09 1.69E-09 1.71E-09 2.33E-09 9.89E-10 -2.50E-11Std Dev Un-Biased 1.10E-08 1.07E-08 1.08E-08 1.03E-08 1.02E-08 9.98E-09 1.05E-08Ps90%/90% (+KTL) Un-Biased 3.05E-08 3.07E-08 3.14E-08 3.00E-08 3.04E-08 2.84E-08 2.89E-08Ps90%/90% (-KTL) Un-Biased -2.96E-08 -2.82E-08 -2.80E-08 -2.66E-08 -2.57E-08 -2.64E-08 -2.89E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 421: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

421

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=5

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.207. Plot of Input Offset Current @ 5V, VCM=5V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 422: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

422

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.207. Raw data for Input Offset Current @ 5V, VCM=5V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=5V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -6.91E-09 -6.13E-09 -7.04E-09 -6.77E-09 -6.15E-09 -6.94E-09 7.76E-09879 -7.79E-09 -7.29E-09 -6.23E-09 -4.40E-09 4.17E-09 4.42E-10 1.67E-08882 -9.72E-09 -8.77E-09 -8.08E-09 -8.83E-09 -1.01E-08 -1.22E-08 4.42E-09883 5.41E-09 6.94E-09 6.89E-09 1.06E-08 1.02E-08 7.41E-09 2.23E-08885 -5.95E-09 -5.95E-09 -6.82E-09 -4.88E-10 -2.07E-09 -4.23E-09 1.15E-08886 -2.52E-09 -3.21E-09 -1.96E-09 -2.45E-09 -2.24E-09 -2.41E-09 -2.14E-09887 -6.43E-09 -6.66E-09 -4.90E-09 -4.01E-09 -3.29E-09 -4.53E-09 -6.85E-09891 1.38E-08 1.43E-08 1.52E-08 1.67E-08 1.66E-08 1.49E-08 1.36E-08892 -6.69E-09 -6.39E-09 -6.69E-09 -4.70E-09 -2.45E-09 -4.64E-09 -6.91E-09895 -1.40E-08 -1.46E-08 -1.49E-08 -1.49E-08 -1.41E-08 -1.38E-08 -1.46E-08896 -5.82E-09 -5.96E-09 -5.80E-09 -5.78E-09 -5.82E-09 -5.86E-09 -5.79E-09

Biased StatisticsAverage Biased -4.99E-09 -4.24E-09 -4.25E-09 -1.98E-09 -7.91E-10 -3.09E-09 1.25E-08Std Dev Biased 5.98E-09 6.35E-09 6.26E-09 7.68E-09 8.13E-09 7.43E-09 7.12E-09Ps90%/90% (+KTL) Biased 1.14E-08 1.32E-08 1.29E-08 1.91E-08 2.15E-08 1.73E-08 3.21E-08Ps90%/90% (-KTL) Biased -2.14E-08 -2.16E-08 -2.14E-08 -2.30E-08 -2.31E-08 -2.35E-08 -6.99E-09Un-Biased StatisticsAverage Un-Biased -3.16E-09 -3.32E-09 -2.65E-09 -1.87E-09 -1.09E-09 -2.10E-09 -3.36E-09Std Dev Un-Biased 1.04E-08 1.07E-08 1.11E-08 1.15E-08 1.11E-08 1.05E-08 1.05E-08Ps90%/90% (+KTL) Un-Biased 2.53E-08 2.60E-08 2.77E-08 2.97E-08 2.93E-08 2.66E-08 2.54E-08Ps90%/90% (-KTL) Un-Biased -3.16E-08 -3.26E-08 -3.30E-08 -3.34E-08 -3.15E-08 -3.08E-08 -3.22E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 423: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

423

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E-08

-6.00E-08

-4.00E-08

-2.00E-08

0.00E+00

2.00E-08

4.00E-08

6.00E-08

8.00E-08

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Inpu

t Offs

et C

urre

nt @

5V,

VC

M=5

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.208. Plot of Input Offset Current @ 5V, VCM=5V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 424: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

424

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.208. Raw data for Input Offset Current @ 5V, VCM=5V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Input Offset Current @ 5V, VCM=5V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -8.92E-09 -6.91E-09 -6.61E-09 -5.39E-09 -4.91E-09 -6.46E-09 7.68E-09879 -1.26E-08 -1.20E-08 -9.74E-09 -1.07E-08 -4.40E-09 -5.42E-09 8.92E-09882 1.14E-08 1.25E-08 1.29E-08 1.31E-08 1.16E-08 1.30E-08 2.54E-08883 -6.00E-12 -7.99E-10 -1.50E-09 -4.46E-10 -4.90E-10 -2.59E-09 1.64E-08885 1.76E-09 2.39E-09 2.94E-09 8.02E-09 4.82E-09 4.64E-09 1.95E-08886 -5.17E-09 -4.37E-09 -4.85E-09 -3.38E-09 -2.76E-09 -4.20E-09 -5.63E-09887 1.53E-08 1.40E-08 1.37E-08 1.34E-08 1.34E-08 1.25E-08 1.41E-08891 1.44E-08 1.39E-08 1.29E-08 1.50E-08 1.56E-08 1.52E-08 1.44E-08892 -1.21E-08 -1.08E-08 -9.02E-09 -8.38E-09 -6.39E-09 -7.12E-09 -1.05E-08895 2.03E-09 1.85E-09 2.53E-09 3.10E-09 1.77E-09 7.33E-10 5.25E-10896 -8.71E-10 -1.57E-09 -1.46E-09 -1.39E-09 -1.43E-09 -1.62E-09 -1.55E-09

Biased StatisticsAverage Biased -1.67E-09 -9.61E-10 -4.09E-10 9.18E-10 1.33E-09 6.29E-10 1.56E-08Std Dev Biased 9.45E-09 9.35E-09 8.86E-09 9.72E-09 6.95E-09 8.15E-09 7.40E-09Ps90%/90% (+KTL) Biased 2.43E-08 2.47E-08 2.39E-08 2.76E-08 2.04E-08 2.30E-08 3.58E-08Ps90%/90% (-KTL) Biased -2.76E-08 -2.66E-08 -2.47E-08 -2.57E-08 -1.77E-08 -2.17E-08 -4.72E-09Un-Biased StatisticsAverage Un-Biased 2.88E-09 2.93E-09 3.05E-09 3.93E-09 4.33E-09 3.43E-09 2.58E-09Std Dev Un-Biased 1.20E-08 1.10E-08 1.02E-08 1.02E-08 9.77E-09 9.97E-09 1.13E-08Ps90%/90% (+KTL) Un-Biased 3.58E-08 3.32E-08 3.11E-08 3.19E-08 3.11E-08 3.08E-08 3.37E-08Ps90%/90% (-KTL) Un-Biased -3.01E-08 -2.73E-08 -2.50E-08 -2.40E-08 -2.25E-08 -2.39E-08 -2.85E-08Specification MIN -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08 -6.50E-08Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08 6.50E-08Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 425: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

425

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=5

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.209. Plot of Positive Input Bias Current @ 5V, VCM=5V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 426: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

426

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.209. Raw data for Positive Input Bias Current @ 5V, VCM=5V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=5V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.68E-07 4.01E-07 4.33E-07 4.58E-07 5.00E-07 4.60E-07 4.36E-07879 4.10E-07 4.39E-07 4.66E-07 4.93E-07 5.47E-07 5.07E-07 4.85E-07882 4.16E-07 4.47E-07 4.77E-07 5.04E-07 5.43E-07 5.07E-07 4.79E-07883 4.48E-07 4.79E-07 5.10E-07 5.32E-07 5.75E-07 5.36E-07 5.09E-07885 4.06E-07 4.35E-07 4.64E-07 5.02E-07 5.36E-07 5.01E-07 4.72E-07886 3.96E-07 4.24E-07 4.53E-07 4.77E-07 5.19E-07 5.06E-07 4.54E-07887 4.30E-07 4.57E-07 4.89E-07 5.14E-07 5.55E-07 5.40E-07 4.83E-07891 4.30E-07 4.54E-07 4.83E-07 5.08E-07 5.51E-07 5.36E-07 4.77E-07892 4.60E-07 4.92E-07 5.19E-07 5.50E-07 5.97E-07 5.82E-07 5.19E-07895 4.38E-07 4.71E-07 5.02E-07 5.29E-07 5.75E-07 5.58E-07 4.97E-07896 4.28E-07 4.27E-07 4.27E-07 4.26E-07 4.26E-07 4.26E-07 4.27E-07

Biased StatisticsAverage Biased 4.10E-07 4.40E-07 4.70E-07 4.98E-07 5.40E-07 5.02E-07 4.76E-07Std Dev Biased 2.85E-08 2.77E-08 2.76E-08 2.66E-08 2.72E-08 2.73E-08 2.61E-08Ps90%/90% (+KTL) Biased 4.88E-07 5.16E-07 5.45E-07 5.71E-07 6.15E-07 5.77E-07 5.48E-07Ps90%/90% (-KTL) Biased 3.31E-07 3.64E-07 3.94E-07 4.25E-07 4.66E-07 4.27E-07 4.04E-07Un-Biased StatisticsAverage Un-Biased 4.31E-07 4.60E-07 4.89E-07 5.16E-07 5.59E-07 5.44E-07 4.86E-07Std Dev Un-Biased 2.30E-08 2.47E-08 2.47E-08 2.67E-08 2.93E-08 2.80E-08 2.38E-08Ps90%/90% (+KTL) Un-Biased 4.94E-07 5.27E-07 5.57E-07 5.89E-07 6.40E-07 6.21E-07 5.51E-07Ps90%/90% (-KTL) Un-Biased 3.68E-07 3.92E-07 4.21E-07 4.42E-07 4.79E-07 4.68E-07 4.21E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 427: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

427

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=5

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.210. Plot of Positive Input Bias Current @ 5V, VCM=5V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 428: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

428

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.210. Raw data for Positive Input Bias Current @ 5V, VCM=5V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=5V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.95E-07 4.30E-07 4.61E-07 4.89E-07 5.31E-07 4.98E-07 4.76E-07879 4.49E-07 4.72E-07 4.99E-07 5.24E-07 5.85E-07 5.48E-07 5.27E-07882 3.82E-07 4.14E-07 4.41E-07 4.65E-07 5.03E-07 4.70E-07 4.50E-07883 4.58E-07 4.93E-07 5.21E-07 5.48E-07 5.91E-07 5.50E-07 5.23E-07885 4.38E-07 4.68E-07 5.04E-07 5.37E-07 5.68E-07 5.30E-07 5.07E-07886 3.83E-07 4.10E-07 4.38E-07 4.61E-07 5.01E-07 4.89E-07 4.37E-07887 4.60E-07 4.89E-07 5.16E-07 5.41E-07 5.85E-07 5.74E-07 5.18E-07891 4.15E-07 4.46E-07 4.76E-07 5.01E-07 5.42E-07 5.28E-07 4.73E-07892 4.32E-07 4.68E-07 4.99E-07 5.25E-07 5.69E-07 5.55E-07 4.94E-07895 3.92E-07 4.22E-07 4.52E-07 4.78E-07 5.22E-07 5.06E-07 4.51E-07896 4.10E-07 4.13E-07 4.10E-07 4.11E-07 4.11E-07 4.10E-07 4.12E-07

Biased StatisticsAverage Biased 4.24E-07 4.55E-07 4.85E-07 5.13E-07 5.56E-07 5.19E-07 4.97E-07Std Dev Biased 3.38E-08 3.25E-08 3.29E-08 3.46E-08 3.74E-08 3.45E-08 3.28E-08Ps90%/90% (+KTL) Biased 5.17E-07 5.44E-07 5.76E-07 6.07E-07 6.58E-07 6.14E-07 5.87E-07Ps90%/90% (-KTL) Biased 3.32E-07 3.66E-07 3.95E-07 4.18E-07 4.53E-07 4.25E-07 4.07E-07Un-Biased StatisticsAverage Un-Biased 4.16E-07 4.47E-07 4.76E-07 5.01E-07 5.44E-07 5.30E-07 4.75E-07Std Dev Un-Biased 3.13E-08 3.25E-08 3.19E-08 3.28E-08 3.41E-08 3.48E-08 3.22E-08Ps90%/90% (+KTL) Un-Biased 5.02E-07 5.36E-07 5.64E-07 5.91E-07 6.37E-07 6.26E-07 5.63E-07Ps90%/90% (-KTL) Un-Biased 3.31E-07 3.58E-07 3.89E-07 4.11E-07 4.50E-07 4.35E-07 3.86E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 429: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

429

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=5

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.211. Plot of Positive Input Bias Current @ 5V, VCM=5V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 430: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

430

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.211. Raw data for Positive Input Bias Current @ 5V, VCM=5V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=5V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.77E-07 4.10E-07 4.39E-07 4.63E-07 5.04E-07 4.68E-07 4.42E-07879 4.41E-07 4.65E-07 5.15E-07 5.20E-07 5.80E-07 5.47E-07 5.26E-07882 3.79E-07 4.25E-07 4.41E-07 4.62E-07 4.98E-07 4.63E-07 4.41E-07883 4.46E-07 4.79E-07 5.06E-07 5.64E-07 5.78E-07 5.40E-07 5.12E-07885 4.39E-07 4.69E-07 5.00E-07 5.41E-07 5.72E-07 5.32E-07 5.05E-07886 3.82E-07 4.11E-07 4.40E-07 4.65E-07 5.04E-07 4.91E-07 4.42E-07887 4.38E-07 4.63E-07 4.93E-07 5.25E-07 5.63E-07 5.48E-07 4.95E-07891 4.31E-07 4.62E-07 4.90E-07 5.17E-07 5.58E-07 5.43E-07 4.87E-07892 4.45E-07 4.77E-07 5.05E-07 5.33E-07 5.75E-07 5.60E-07 5.01E-07895 3.95E-07 4.23E-07 4.53E-07 4.78E-07 5.22E-07 5.07E-07 4.52E-07896 3.98E-07 3.99E-07 3.98E-07 3.97E-07 3.97E-07 3.98E-07 3.98E-07

Biased StatisticsAverage Biased 4.16E-07 4.50E-07 4.80E-07 5.10E-07 5.47E-07 5.10E-07 4.85E-07Std Dev Biased 3.52E-08 3.01E-08 3.72E-08 4.62E-08 4.14E-08 4.09E-08 4.04E-08Ps90%/90% (+KTL) Biased 5.13E-07 5.32E-07 5.82E-07 6.37E-07 6.60E-07 6.22E-07 5.96E-07Ps90%/90% (-KTL) Biased 3.20E-07 3.67E-07 3.78E-07 3.83E-07 4.33E-07 3.98E-07 3.74E-07Un-Biased StatisticsAverage Un-Biased 4.18E-07 4.47E-07 4.76E-07 5.03E-07 5.44E-07 5.30E-07 4.75E-07Std Dev Un-Biased 2.81E-08 2.85E-08 2.81E-08 3.00E-08 3.01E-08 2.94E-08 2.66E-08Ps90%/90% (+KTL) Un-Biased 4.95E-07 5.25E-07 5.53E-07 5.86E-07 6.27E-07 6.10E-07 5.48E-07Ps90%/90% (-KTL) Un-Biased 3.41E-07 3.69E-07 3.99E-07 4.21E-07 4.62E-07 4.49E-07 4.02E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 431: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

431

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Inpu

t Bia

s C

urre

nt @

5V,

VC

M=5

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.212. Plot of Positive Input Bias Current @ 5V, VCM=5V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 432: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

432

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.212. Raw data for Positive Input Bias Current @ 5V, VCM=5V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Input Bias Current @ 5V, VCM=5V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.78E-07 4.11E-07 4.40E-07 4.64E-07 5.06E-07 4.68E-07 4.43E-07879 4.06E-07 4.34E-07 4.87E-07 4.92E-07 5.45E-07 5.07E-07 4.83E-07882 4.27E-07 4.77E-07 4.94E-07 5.18E-07 5.55E-07 5.21E-07 4.93E-07883 4.59E-07 4.89E-07 5.18E-07 5.73E-07 5.85E-07 5.48E-07 5.22E-07885 3.89E-07 4.17E-07 4.49E-07 4.87E-07 5.19E-07 4.81E-07 4.55E-07886 3.91E-07 4.19E-07 4.41E-07 4.66E-07 5.12E-07 4.99E-07 4.42E-07887 4.35E-07 4.64E-07 4.95E-07 5.22E-07 5.60E-07 5.47E-07 4.91E-07891 4.48E-07 4.75E-07 5.03E-07 5.28E-07 5.68E-07 5.55E-07 4.97E-07892 4.53E-07 4.86E-07 5.16E-07 5.46E-07 5.92E-07 5.77E-07 5.13E-07895 4.32E-07 4.64E-07 4.97E-07 5.23E-07 5.70E-07 5.54E-07 4.90E-07896 4.27E-07 4.30E-07 4.31E-07 4.30E-07 4.28E-07 4.31E-07 4.29E-07

Biased StatisticsAverage Biased 4.12E-07 4.46E-07 4.77E-07 5.07E-07 5.42E-07 5.05E-07 4.79E-07Std Dev Biased 3.24E-08 3.54E-08 3.24E-08 4.17E-08 3.09E-08 3.19E-08 3.13E-08Ps90%/90% (+KTL) Biased 5.00E-07 5.43E-07 5.66E-07 6.21E-07 6.27E-07 5.93E-07 5.65E-07Ps90%/90% (-KTL) Biased 3.23E-07 3.48E-07 3.89E-07 3.92E-07 4.57E-07 4.18E-07 3.93E-07Un-Biased StatisticsAverage Un-Biased 4.32E-07 4.62E-07 4.90E-07 5.17E-07 5.60E-07 5.46E-07 4.87E-07Std Dev Un-Biased 2.45E-08 2.58E-08 2.87E-08 3.00E-08 2.96E-08 2.87E-08 2.65E-08Ps90%/90% (+KTL) Un-Biased 4.99E-07 5.32E-07 5.69E-07 5.99E-07 6.41E-07 6.25E-07 5.60E-07Ps90%/90% (-KTL) Un-Biased 3.65E-07 3.91E-07 4.12E-07 4.35E-07 4.79E-07 4.68E-07 4.14E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 433: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

433

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=5V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.213. Plot of Negative Input Bias Current @ 5V, VCM=5V #1 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 434: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

434

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.213. Raw data for Negative Input Bias Current @ 5V, VCM=5V #1 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=5V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.68E-07 4.00E-07 4.30E-07 4.56E-07 4.96E-07 4.60E-07 4.20E-07879 4.00E-07 4.30E-07 4.56E-07 4.84E-07 5.30E-07 4.94E-07 4.57E-07882 4.10E-07 4.40E-07 4.73E-07 4.96E-07 5.35E-07 5.00E-07 4.59E-07883 4.47E-07 4.80E-07 5.08E-07 5.30E-07 5.73E-07 5.36E-07 4.93E-07885 3.91E-07 4.28E-07 4.63E-07 4.91E-07 5.28E-07 4.90E-07 4.50E-07886 3.92E-07 4.21E-07 4.51E-07 4.75E-07 5.19E-07 5.05E-07 4.51E-07887 4.12E-07 4.40E-07 4.70E-07 4.97E-07 5.40E-07 5.25E-07 4.69E-07891 4.24E-07 4.53E-07 4.79E-07 5.04E-07 5.46E-07 5.32E-07 4.75E-07892 4.56E-07 4.88E-07 5.18E-07 5.45E-07 5.92E-07 5.76E-07 5.15E-07895 4.30E-07 4.60E-07 4.92E-07 5.20E-07 5.65E-07 5.49E-07 4.88E-07896 4.25E-07 4.25E-07 4.25E-07 4.25E-07 4.25E-07 4.27E-07 4.25E-07

Biased StatisticsAverage Biased 4.03E-07 4.36E-07 4.66E-07 4.91E-07 5.32E-07 4.96E-07 4.56E-07Std Dev Biased 2.89E-08 2.89E-08 2.82E-08 2.66E-08 2.72E-08 2.72E-08 2.63E-08Ps90%/90% (+KTL) Biased 4.82E-07 5.15E-07 5.43E-07 5.64E-07 6.07E-07 5.71E-07 5.28E-07Ps90%/90% (-KTL) Biased 3.24E-07 3.56E-07 3.89E-07 4.18E-07 4.58E-07 4.22E-07 3.83E-07Un-Biased StatisticsAverage Un-Biased 4.23E-07 4.52E-07 4.82E-07 5.08E-07 5.52E-07 5.37E-07 4.80E-07Std Dev Un-Biased 2.34E-08 2.47E-08 2.50E-08 2.61E-08 2.78E-08 2.69E-08 2.41E-08Ps90%/90% (+KTL) Un-Biased 4.87E-07 5.20E-07 5.50E-07 5.80E-07 6.29E-07 6.11E-07 5.46E-07Ps90%/90% (-KTL) Un-Biased 3.58E-07 3.85E-07 4.13E-07 4.37E-07 4.76E-07 4.63E-07 4.14E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 435: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

435

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=5V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.214. Plot of Negative Input Bias Current @ 5V, VCM=5V #2 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 436: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

436

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.214. Raw data for Negative Input Bias Current @ 5V, VCM=5V #2 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=5V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.97E-07 4.32E-07 4.65E-07 4.88E-07 5.28E-07 4.93E-07 4.51E-07879 4.47E-07 4.67E-07 4.91E-07 5.17E-07 5.69E-07 5.37E-07 4.99E-07882 3.82E-07 4.10E-07 4.38E-07 4.62E-07 5.02E-07 4.70E-07 4.32E-07883 4.57E-07 4.88E-07 5.19E-07 5.42E-07 5.85E-07 5.49E-07 5.04E-07885 4.33E-07 4.64E-07 4.95E-07 5.25E-07 5.60E-07 5.27E-07 4.83E-07886 3.93E-07 4.20E-07 4.47E-07 4.72E-07 5.10E-07 5.01E-07 4.49E-07887 4.47E-07 4.72E-07 5.00E-07 5.27E-07 5.67E-07 5.57E-07 5.01E-07891 4.18E-07 4.46E-07 4.75E-07 5.00E-07 5.39E-07 5.28E-07 4.74E-07892 4.38E-07 4.72E-07 5.02E-07 5.28E-07 5.70E-07 5.57E-07 5.00E-07895 3.86E-07 4.15E-07 4.45E-07 4.72E-07 5.16E-07 5.03E-07 4.46E-07896 4.18E-07 4.21E-07 4.20E-07 4.19E-07 4.16E-07 4.21E-07 4.19E-07

Biased StatisticsAverage Biased 4.23E-07 4.52E-07 4.81E-07 5.07E-07 5.49E-07 5.15E-07 4.74E-07Std Dev Biased 3.23E-08 3.11E-08 3.10E-08 3.15E-08 3.32E-08 3.27E-08 3.14E-08Ps90%/90% (+KTL) Biased 5.11E-07 5.38E-07 5.67E-07 5.93E-07 6.40E-07 6.04E-07 5.60E-07Ps90%/90% (-KTL) Biased 3.35E-07 3.67E-07 3.96E-07 4.21E-07 4.58E-07 4.25E-07 3.88E-07Un-Biased StatisticsAverage Un-Biased 4.16E-07 4.45E-07 4.74E-07 5.00E-07 5.40E-07 5.29E-07 4.74E-07Std Dev Un-Biased 2.68E-08 2.74E-08 2.74E-08 2.75E-08 2.79E-08 2.77E-08 2.63E-08Ps90%/90% (+KTL) Un-Biased 4.90E-07 5.20E-07 5.49E-07 5.75E-07 6.17E-07 6.05E-07 5.46E-07Ps90%/90% (-KTL) Un-Biased 3.43E-07 3.70E-07 3.98E-07 4.24E-07 4.64E-07 4.53E-07 4.02E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 437: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

437

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=5V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.215. Plot of Negative Input Bias Current @ 5V, VCM=5V #3 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 438: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

438

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.215. Raw data for Negative Input Bias Current @ 5V, VCM=5V #3 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=5V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.84E-07 4.14E-07 4.44E-07 4.69E-07 5.09E-07 4.72E-07 4.34E-07879 4.48E-07 4.72E-07 5.19E-07 5.24E-07 5.77E-07 5.44E-07 5.08E-07882 3.86E-07 4.33E-07 4.45E-07 4.68E-07 5.07E-07 4.75E-07 4.36E-07883 4.39E-07 4.69E-07 4.99E-07 5.52E-07 5.67E-07 5.31E-07 4.89E-07885 4.45E-07 4.75E-07 5.05E-07 5.41E-07 5.74E-07 5.36E-07 4.93E-07886 3.84E-07 4.13E-07 4.41E-07 4.64E-07 5.04E-07 4.93E-07 4.42E-07887 4.43E-07 4.67E-07 4.95E-07 5.21E-07 5.64E-07 5.51E-07 4.97E-07891 4.15E-07 4.46E-07 4.74E-07 5.00E-07 5.40E-07 5.27E-07 4.74E-07892 4.48E-07 4.81E-07 5.11E-07 5.37E-07 5.78E-07 5.64E-07 5.07E-07895 4.07E-07 4.36E-07 4.66E-07 4.92E-07 5.35E-07 5.22E-07 4.65E-07896 4.03E-07 4.04E-07 4.03E-07 4.02E-07 4.02E-07 4.04E-07 4.04E-07

Biased StatisticsAverage Biased 4.20E-07 4.53E-07 4.82E-07 5.11E-07 5.47E-07 5.12E-07 4.72E-07Std Dev Biased 3.26E-08 2.75E-08 3.52E-08 4.00E-08 3.54E-08 3.51E-08 3.44E-08Ps90%/90% (+KTL) Biased 5.10E-07 5.28E-07 5.79E-07 6.20E-07 6.44E-07 6.08E-07 5.66E-07Ps90%/90% (-KTL) Biased 3.31E-07 3.77E-07 3.86E-07 4.01E-07 4.50E-07 4.15E-07 3.78E-07Un-Biased StatisticsAverage Un-Biased 4.19E-07 4.49E-07 4.77E-07 5.03E-07 5.44E-07 5.31E-07 4.77E-07Std Dev Un-Biased 2.66E-08 2.67E-08 2.71E-08 2.80E-08 2.86E-08 2.78E-08 2.61E-08Ps90%/90% (+KTL) Un-Biased 4.92E-07 5.22E-07 5.52E-07 5.80E-07 6.22E-07 6.08E-07 5.48E-07Ps90%/90% (-KTL) Un-Biased 3.47E-07 3.75E-07 4.03E-07 4.26E-07 4.66E-07 4.55E-07 4.05E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 439: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

439

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E-06

-8.00E-07

-6.00E-07

-4.00E-07

-2.00E-07

0.00E+00

2.00E-07

4.00E-07

6.00E-07

8.00E-07

1.00E-06

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e In

put B

ias

Cur

rent

@ 5

V, V

CM

=5V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased

Specification MIN Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.216. Plot of Negative Input Bias Current @ 5V, VCM=5V #4 (A) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 440: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

440

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.216. Raw data for Negative Input Bias Current @ 5V, VCM=5V #4 (A) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Input Bias Current @ 5V, VCM=5V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.85E-07 4.17E-07 4.45E-07 4.69E-07 5.11E-07 4.74E-07 4.34E-07879 4.15E-07 4.45E-07 4.96E-07 5.01E-07 5.49E-07 5.13E-07 4.74E-07882 4.16E-07 4.63E-07 4.80E-07 5.02E-07 5.43E-07 5.07E-07 4.67E-07883 4.56E-07 4.88E-07 5.18E-07 5.71E-07 5.84E-07 5.51E-07 5.03E-07885 3.85E-07 4.14E-07 4.44E-07 4.78E-07 5.12E-07 4.75E-07 4.35E-07886 3.89E-07 4.19E-07 4.47E-07 4.75E-07 5.13E-07 4.98E-07 4.48E-07887 4.17E-07 4.50E-07 4.80E-07 5.06E-07 5.47E-07 5.34E-07 4.75E-07891 4.34E-07 4.62E-07 4.89E-07 5.12E-07 5.52E-07 5.40E-07 4.83E-07892 4.62E-07 4.99E-07 5.25E-07 5.53E-07 5.96E-07 5.83E-07 5.24E-07895 4.32E-07 4.62E-07 4.94E-07 5.19E-07 5.67E-07 5.52E-07 4.90E-07896 4.27E-07 4.30E-07 4.28E-07 4.29E-07 4.34E-07 4.30E-07 4.30E-07

Biased StatisticsAverage Biased 4.12E-07 4.45E-07 4.77E-07 5.04E-07 5.40E-07 5.04E-07 4.63E-07Std Dev Biased 2.93E-08 3.14E-08 3.24E-08 4.01E-08 3.02E-08 3.18E-08 2.91E-08Ps90%/90% (+KTL) Biased 4.92E-07 5.31E-07 5.66E-07 6.14E-07 6.23E-07 5.91E-07 5.43E-07Ps90%/90% (-KTL) Biased 3.31E-07 3.59E-07 3.88E-07 3.94E-07 4.57E-07 4.17E-07 3.83E-07Un-Biased StatisticsAverage Un-Biased 4.27E-07 4.58E-07 4.87E-07 5.13E-07 5.55E-07 5.41E-07 4.84E-07Std Dev Un-Biased 2.68E-08 2.88E-08 2.79E-08 2.82E-08 3.04E-08 3.09E-08 2.75E-08Ps90%/90% (+KTL) Un-Biased 5.00E-07 5.37E-07 5.63E-07 5.90E-07 6.38E-07 6.26E-07 5.60E-07Ps90%/90% (-KTL) Un-Biased 3.53E-07 3.79E-07 4.11E-07 4.35E-07 4.72E-07 4.57E-07 4.09E-07Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07Status PASS PASS PASS PASS PASS PASS PASSSpecification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 441: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

441

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#1 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.217. Plot of Large Signal Voltage Gain @ 5V #1 (V/mV) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 442: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

442

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.217. Raw data for Large Signal Voltage Gain @ 5V #1 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #1 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.82E+03 1.94E+03 2.05E+03 1.55E+03 1.60E+03 1.67E+03 1.81E+03879 1.78E+03 1.86E+03 1.79E+03 1.76E+03 2.06E+03 1.90E+03 2.30E+03882 1.93E+03 1.75E+03 1.68E+03 2.20E+03 1.59E+03 1.79E+03 1.20E+03883 2.26E+03 1.99E+03 1.41E+03 1.61E+03 1.93E+03 1.44E+03 2.08E+03885 1.59E+03 1.90E+03 1.74E+03 1.72E+03 1.57E+03 1.75E+03 1.81E+03886 2.07E+03 1.56E+03 1.85E+03 2.53E+03 1.25E+03 1.78E+03 3.33E+03887 2.35E+03 2.73E+03 2.49E+03 2.02E+03 2.07E+03 2.43E+03 2.19E+03891 1.96E+03 2.16E+03 1.81E+03 1.70E+03 1.82E+03 2.38E+03 1.71E+03892 2.70E+03 1.91E+03 2.31E+03 2.04E+03 2.18E+03 2.20E+03 2.15E+03895 2.22E+03 1.95E+03 2.19E+03 1.83E+03 1.82E+03 2.11E+03 1.82E+03896 2.26E+03 2.36E+03 2.43E+03 2.54E+03 2.49E+03 2.46E+03 2.36E+03

Biased StatisticsAverage Biased 1.88E+03 1.89E+03 1.73E+03 1.77E+03 1.75E+03 1.71E+03 1.84E+03Std Dev Biased 2.47E+02 9.06E+01 2.28E+02 2.55E+02 2.30E+02 1.70E+02 4.11E+02Ps90%/90% (+KTL) Biased 2.55E+03 2.14E+03 2.36E+03 2.47E+03 2.38E+03 2.17E+03 2.97E+03Ps90%/90% (-KTL) Biased 1.20E+03 1.64E+03 1.11E+03 1.07E+03 1.12E+03 1.24E+03 7.14E+02Un-Biased StatisticsAverage Un-Biased 2.26E+03 2.06E+03 2.13E+03 2.02E+03 1.83E+03 2.18E+03 2.24E+03Std Dev Un-Biased 2.84E+02 4.31E+02 2.96E+02 3.15E+02 3.59E+02 2.59E+02 6.45E+02Ps90%/90% (+KTL) Un-Biased 3.04E+03 3.25E+03 2.94E+03 2.89E+03 2.81E+03 2.89E+03 4.01E+03Ps90%/90% (-KTL) Un-Biased 1.48E+03 8.81E+02 1.32E+03 1.16E+03 8.41E+02 1.47E+03 4.71E+02Specification MIN 6.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 443: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

443

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#2 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.218. Plot of Large Signal Voltage Gain @ 5V #2 (V/mV) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 444: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

444

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.218. Raw data for Large Signal Voltage Gain @ 5V #2 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #2 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.31E+03 1.90E+03 2.00E+03 2.10E+03 1.96E+03 1.90E+03 1.90E+03879 1.76E+03 1.79E+03 1.77E+03 2.09E+03 2.70E+03 1.99E+03 1.92E+03882 2.23E+03 2.05E+03 2.07E+03 1.74E+03 2.09E+03 2.02E+03 1.89E+03883 2.46E+03 2.32E+03 1.79E+03 2.38E+03 1.84E+03 2.19E+03 2.40E+03885 2.46E+03 2.25E+03 2.27E+03 1.84E+03 2.19E+03 1.82E+03 2.13E+03886 1.72E+03 2.07E+03 1.76E+03 1.69E+03 1.58E+03 1.73E+03 1.84E+03887 1.07E+03 8.83E+02 2.51E+03 2.88E+03 3.02E+03 1.68E+03 1.26E+03891 2.07E+03 1.93E+03 1.78E+03 1.95E+03 1.96E+03 2.01E+03 1.86E+03892 1.78E+03 2.21E+03 1.83E+03 1.99E+03 1.41E+03 1.62E+03 1.82E+03895 2.17E+03 2.03E+03 1.87E+03 1.84E+03 1.82E+03 1.60E+03 1.94E+03896 3.09E+03 3.01E+03 3.00E+03 3.06E+03 2.95E+03 2.62E+03 3.05E+03

Biased StatisticsAverage Biased 2.24E+03 2.06E+03 1.98E+03 2.03E+03 2.16E+03 1.98E+03 2.05E+03Std Dev Biased 2.89E+02 2.24E+02 2.07E+02 2.51E+02 3.29E+02 1.40E+02 2.20E+02Ps90%/90% (+KTL) Biased 3.04E+03 2.67E+03 2.55E+03 2.72E+03 3.06E+03 2.37E+03 2.65E+03Ps90%/90% (-KTL) Biased 1.45E+03 1.45E+03 1.41E+03 1.34E+03 1.25E+03 1.60E+03 1.45E+03Un-Biased StatisticsAverage Un-Biased 1.76E+03 1.83E+03 1.95E+03 2.07E+03 1.96E+03 1.73E+03 1.74E+03Std Dev Un-Biased 4.32E+02 5.36E+02 3.14E+02 4.66E+02 6.31E+02 1.65E+02 2.72E+02Ps90%/90% (+KTL) Un-Biased 2.95E+03 3.30E+03 2.81E+03 3.35E+03 3.69E+03 2.18E+03 2.49E+03Ps90%/90% (-KTL) Un-Biased 5.77E+02 3.55E+02 1.09E+03 7.91E+02 2.30E+02 1.27E+03 9.98E+02Specification MIN 6.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status FAIL PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 445: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

445

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

3.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#3 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.219. Plot of Large Signal Voltage Gain @ 5V #3 (V/mV) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 446: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

446

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.219. Raw data for Large Signal Voltage Gain @ 5V #3 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #3 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 2.80E+03 2.59E+03 2.18E+03 2.42E+03 2.48E+03 2.40E+03 2.28E+03879 2.05E+03 1.95E+03 2.03E+03 1.79E+03 2.49E+03 1.97E+03 1.94E+03882 2.07E+03 2.14E+03 1.34E+03 1.88E+03 1.97E+03 2.05E+03 1.73E+03883 2.82E+03 1.71E+03 1.71E+03 1.85E+03 1.50E+03 2.06E+03 1.67E+03885 2.17E+03 2.64E+03 2.14E+03 1.92E+03 1.82E+03 1.94E+03 2.23E+03886 2.58E+03 2.84E+03 2.08E+03 2.29E+03 2.26E+03 1.94E+03 2.48E+03887 2.89E+03 2.68E+03 1.80E+03 2.07E+03 3.40E+03 1.95E+03 2.18E+03891 1.99E+03 1.93E+03 1.69E+03 1.79E+03 3.02E+03 2.18E+03 1.70E+03892 2.50E+03 2.09E+03 1.74E+03 2.83E+03 3.43E+03 2.59E+03 2.59E+03895 2.16E+03 2.30E+03 2.41E+03 1.90E+03 2.16E+03 2.01E+03 2.09E+03896 2.17E+03 2.05E+03 2.25E+03 2.00E+03 2.25E+03 2.08E+03 2.18E+03

Biased StatisticsAverage Biased 2.38E+03 2.21E+03 1.88E+03 1.97E+03 2.05E+03 2.08E+03 1.97E+03Std Dev Biased 3.94E+02 4.04E+02 3.56E+02 2.57E+02 4.30E+02 1.84E+02 2.76E+02Ps90%/90% (+KTL) Biased 3.46E+03 3.32E+03 2.85E+03 2.68E+03 3.23E+03 2.59E+03 2.73E+03Ps90%/90% (-KTL) Biased 1.30E+03 1.10E+03 9.02E+02 1.26E+03 8.74E+02 1.58E+03 1.21E+03Un-Biased StatisticsAverage Un-Biased 2.43E+03 2.37E+03 1.94E+03 2.18E+03 2.85E+03 2.13E+03 2.21E+03Std Dev Un-Biased 3.56E+02 3.84E+02 3.03E+02 4.10E+02 6.12E+02 2.71E+02 3.51E+02Ps90%/90% (+KTL) Un-Biased 3.40E+03 3.42E+03 2.77E+03 3.30E+03 4.53E+03 2.88E+03 3.17E+03Ps90%/90% (-KTL) Un-Biased 1.45E+03 1.31E+03 1.11E+03 1.05E+03 1.18E+03 1.39E+03 1.25E+03Specification MIN 6.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 447: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

447

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E+03

-5.00E+02

0.00E+00

5.00E+02

1.00E+03

1.50E+03

2.00E+03

2.50E+03

3.00E+03

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#4 (V

/mV)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.220. Plot of Large Signal Voltage Gain @ 5V #4 (V/mV) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 448: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

448

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.220. Raw data for Large Signal Voltage Gain @ 5V #4 (V/mV) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #4 (V/mV) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.82E+03 1.76E+03 1.52E+03 1.48E+03 1.53E+03 1.59E+03 1.54E+03879 2.71E+03 1.87E+03 2.11E+03 1.65E+03 1.78E+03 2.24E+03 2.50E+03882 2.48E+03 2.52E+03 2.24E+03 2.06E+03 1.95E+03 1.92E+03 2.38E+03883 2.13E+03 3.04E+03 3.32E+03 1.90E+03 1.80E+03 2.00E+03 1.82E+03885 2.83E+03 2.37E+03 2.32E+03 2.54E+03 1.89E+03 2.45E+03 2.33E+03886 1.78E+03 1.95E+03 1.89E+03 3.27E+03 1.53E+03 1.70E+03 1.63E+03887 2.59E+03 2.28E+03 2.58E+03 3.26E+03 2.12E+03 2.38E+03 1.43E+03891 2.23E+03 2.26E+03 2.14E+03 2.01E+03 1.97E+03 2.44E+03 2.09E+03892 2.03E+03 2.73E+03 2.40E+03 1.99E+03 1.93E+03 3.00E+03 4.09E+03895 2.49E+03 2.42E+03 2.49E+03 2.17E+03 2.50E+03 1.92E+03 2.20E+03896 1.61E+03 2.20E+03 2.53E+03 2.69E+03 2.45E+03 2.20E+03 1.89E+03

Biased StatisticsAverage Biased 2.39E+03 2.31E+03 2.30E+03 1.92E+03 1.79E+03 2.04E+03 2.11E+03Std Dev Biased 4.19E+02 5.16E+02 6.51E+02 4.08E+02 1.61E+02 3.24E+02 4.14E+02Ps90%/90% (+KTL) Biased 3.54E+03 3.73E+03 4.09E+03 3.04E+03 2.23E+03 2.93E+03 3.25E+03Ps90%/90% (-KTL) Biased 1.25E+03 8.97E+02 5.18E+02 8.05E+02 1.35E+03 1.15E+03 9.75E+02Un-Biased StatisticsAverage Un-Biased 2.22E+03 2.33E+03 2.30E+03 2.54E+03 2.01E+03 2.29E+03 2.29E+03Std Dev Un-Biased 3.32E+02 2.84E+02 2.84E+02 6.67E+02 3.49E+02 5.06E+02 1.06E+03Ps90%/90% (+KTL) Un-Biased 3.13E+03 3.11E+03 3.08E+03 4.37E+03 2.97E+03 3.67E+03 5.19E+03Ps90%/90% (-KTL) Un-Biased 1.31E+03 1.55E+03 1.52E+03 7.10E+02 1.05E+03 8.99E+02 ########Specification MIN 6.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02 3.00E+02Status PASS PASS PASS PASS PASS PASS FAIL

Total Dose (krad(Si))

Page 449: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

449

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.08E+02

1.10E+02

1.12E+02

1.14E+02

1.16E+02

1.18E+02

1.20E+02

1.22E+02

1.24E+02

1.26E+02

1.28E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.221. Plot of Large Signal Voltage Gain @ 5V #1 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 450: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

450

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.221. Raw data for Large Signal Voltage Gain @ 5V #1 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #1 (dB)24 hr

Anneal 168 hr Anneal

Device 0 10 20 30 50 60 70878 1.25E+02 1.26E+02 1.26E+02 1.24E+02 1.24E+02 1.24E+02 1.25E+02879 1.25E+02 1.25E+02 1.25E+02 1.25E+02 1.26E+02 1.26E+02 1.27E+02882 1.26E+02 1.25E+02 1.25E+02 1.27E+02 1.24E+02 1.25E+02 1.22E+02883 1.27E+02 1.26E+02 1.23E+02 1.24E+02 1.26E+02 1.23E+02 1.26E+02885 1.24E+02 1.26E+02 1.25E+02 1.25E+02 1.24E+02 1.25E+02 1.25E+02886 1.26E+02 1.24E+02 1.25E+02 1.28E+02 1.22E+02 1.25E+02 1.30E+02887 1.27E+02 1.29E+02 1.28E+02 1.26E+02 1.26E+02 1.28E+02 1.27E+02891 1.26E+02 1.27E+02 1.25E+02 1.25E+02 1.25E+02 1.28E+02 1.25E+02892 1.29E+02 1.26E+02 1.27E+02 1.26E+02 1.27E+02 1.27E+02 1.27E+02895 1.27E+02 1.26E+02 1.27E+02 1.25E+02 1.25E+02 1.26E+02 1.25E+02896 1.27E+02 1.27E+02 1.28E+02 1.28E+02 1.28E+02 1.28E+02 1.27E+02

Biased StatisticsAverage Biased 1.25E+02 1.26E+02 1.25E+02 1.25E+02 1.25E+02 1.25E+02 1.25E+02Std Dev Biased 1.11E+00 4.21E-01 1.16E+00 1.18E+00 1.11E+00 8.96E-01 2.14E+00Ps90%/90% (+KTL) Biased 1.28E+02 1.27E+02 1.28E+02 1.28E+02 1.28E+02 1.27E+02 1.31E+02Ps90%/90% (-KTL) Biased 1.22E+02 1.24E+02 1.22E+02 1.22E+02 1.22E+02 1.22E+02 1.19E+02Un-Biased StatisticsAverage Un-Biased 1.27E+02 1.26E+02 1.26E+02 1.26E+02 1.25E+02 1.27E+02 1.27E+02Std Dev Un-Biased 1.06E+00 1.77E+00 1.22E+00 1.30E+00 1.89E+00 1.08E+00 2.27E+00Ps90%/90% (+KTL) Un-Biased 1.30E+02 1.31E+02 1.30E+02 1.30E+02 1.30E+02 1.30E+02 1.33E+02Ps90%/90% (-KTL) Un-Biased 1.24E+02 1.21E+02 1.23E+02 1.22E+02 1.20E+02 1.24E+02 1.21E+02Specification MIN 1.16E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 451: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

451

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.00E+02

1.05E+02

1.10E+02

1.15E+02

1.20E+02

1.25E+02

1.30E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.222. Plot of Large Signal Voltage Gain @ 5V #2 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 452: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

452

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.222. Raw data for Large Signal Voltage Gain @ 5V #2 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #2 (dB)24 hr

Anneal 168 hr Anneal

Device 0 10 20 30 50 60 70878 1.27E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02879 1.25E+02 1.28E+02 1.25E+02 1.26E+02 1.29E+02 1.26E+02 1.26E+02882 1.27E+02 1.26E+02 1.26E+02 1.25E+02 1.26E+02 1.26E+02 1.26E+02883 1.28E+02 1.27E+02 1.25E+02 1.28E+02 1.25E+02 1.27E+02 1.28E+02885 1.28E+02 1.27E+02 1.27E+02 1.25E+02 1.27E+02 1.25E+02 1.27E+02886 1.25E+02 1.26E+02 1.25E+02 1.25E+02 1.24E+02 1.25E+02 1.25E+02887 1.21E+02 1.19E+02 1.28E+02 1.29E+02 1.30E+02 1.24E+02 1.22E+02891 1.26E+02 1.26E+02 1.25E+02 1.26E+02 1.26E+02 1.26E+02 1.25E+02892 1.25E+02 1.27E+02 1.25E+02 1.26E+02 1.23E+02 1.24E+02 1.25E+02895 1.27E+02 1.26E+02 1.25E+02 1.25E+02 1.25E+02 1.24E+02 1.26E+02896 1.30E+02 1.30E+02 1.30E+02 1.30E+02 1.29E+02 1.28E+02 1.30E+02

Biased StatisticsAverage Biased 1.27E+02 1.27E+02 1.26E+02 1.26E+02 1.27E+02 1.26E+02 1.26E+02Std Dev Biased 1.21E+00 9.19E-01 9.02E-01 1.07E+00 1.26E+00 6.06E-01 8.97E-01Ps90%/90% (+KTL) Biased 1.30E+02 1.29E+02 1.28E+02 1.29E+02 1.30E+02 1.28E+02 1.29E+02Ps90%/90% (-KTL) Biased 1.24E+02 1.24E+02 1.23E+02 1.23E+02 1.23E+02 1.24E+02 1.24E+02Un-Biased StatisticsAverage Un-Biased 1.25E+02 1.25E+02 1.26E+02 1.26E+02 1.26E+02 1.25E+02 1.25E+02Std Dev Un-Biased 2.45E+00 3.32E+00 1.28E+00 1.77E+00 2.53E+00 7.94E-01 1.52E+00Ps90%/90% (+KTL) Un-Biased 1.31E+02 1.34E+02 1.29E+02 1.31E+02 1.32E+02 1.27E+02 1.29E+02Ps90%/90% (-KTL) Un-Biased 1.18E+02 1.16E+02 1.22E+02 1.21E+02 1.19E+02 1.23E+02 1.21E+02Specification MIN 1.16E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 453: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

453

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.05E+02

1.10E+02

1.15E+02

1.20E+02

1.25E+02

1.30E+02

1.35E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.223. Plot of Large Signal Voltage Gain @ 5V #3 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 454: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

454

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.223. Raw data for Large Signal Voltage Gain @ 5V #3 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #3 (dB)24 hr

Anneal 168 hr Anneal

Device 0 10 20 30 50 60 70878 1.29E+02 1.28E+02 1.27E+02 1.28E+02 1.28E+02 1.28E+02 1.27E+02879 1.26E+02 1.26E+02 1.26E+02 1.25E+02 1.28E+02 1.26E+02 1.26E+02882 1.26E+02 1.27E+02 1.23E+02 1.25E+02 1.26E+02 1.26E+02 1.25E+02883 1.29E+02 1.25E+02 1.25E+02 1.25E+02 1.23E+02 1.26E+02 1.24E+02885 1.27E+02 1.28E+02 1.27E+02 1.26E+02 1.25E+02 1.26E+02 1.27E+02886 1.28E+02 1.29E+02 1.26E+02 1.27E+02 1.27E+02 1.26E+02 1.28E+02887 1.29E+02 1.38E+02 1.25E+02 1.26E+02 1.31E+02 1.26E+02 1.27E+02891 1.26E+02 1.26E+02 1.25E+02 1.25E+02 1.30E+02 1.27E+02 1.25E+02892 1.28E+02 1.26E+02 1.25E+02 1.29E+02 1.31E+02 1.28E+02 1.28E+02895 1.27E+02 1.27E+02 1.28E+02 1.26E+02 1.27E+02 1.26E+02 1.26E+02896 1.27E+02 1.26E+02 1.27E+02 1.26E+02 1.27E+02 1.26E+02 1.27E+02

Biased StatisticsAverage Biased 1.27E+02 1.27E+02 1.25E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02Std Dev Biased 1.41E+00 1.61E+00 1.79E+00 1.06E+00 1.87E+00 7.35E-01 1.22E+00Ps90%/90% (+KTL) Biased 1.31E+02 1.31E+02 1.30E+02 1.29E+02 1.31E+02 1.28E+02 1.29E+02Ps90%/90% (-KTL) Biased 1.24E+02 1.22E+02 1.20E+02 1.23E+02 1.21E+02 1.24E+02 1.22E+02Un-Biased StatisticsAverage Un-Biased 1.28E+02 1.29E+02 1.26E+02 1.27E+02 1.29E+02 1.27E+02 1.27E+02Std Dev Un-Biased 1.29E+00 4.90E+00 1.30E+00 1.56E+00 1.94E+00 1.05E+00 1.44E+00Ps90%/90% (+KTL) Un-Biased 1.31E+02 1.43E+02 1.29E+02 1.31E+02 1.34E+02 1.29E+02 1.31E+02Ps90%/90% (-KTL) Un-Biased 1.24E+02 1.16E+02 1.22E+02 1.22E+02 1.24E+02 1.24E+02 1.23E+02Specification MIN 1.16E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 455: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

455

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

1.05E+02

1.10E+02

1.15E+02

1.20E+02

1.25E+02

1.30E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Larg

e Si

gnal

Vol

tage

Gai

n @

5V

#4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.224. Plot of Large Signal Voltage Gain @ 5V #4 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 456: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

456

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.224. Raw data for Large Signal Voltage Gain @ 5V #4 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Large Signal Voltage Gain @ 5V #4 (dB)24 hr

Anneal 168 hr Anneal

Device 0 10 20 30 50 60 70878 1.25E+02 1.25E+02 1.24E+02 1.23E+02 1.24E+02 1.24E+02 1.24E+02879 1.29E+02 1.25E+02 1.26E+02 1.24E+02 1.25E+02 1.27E+02 1.28E+02882 1.28E+02 1.28E+02 1.27E+02 1.26E+02 1.26E+02 1.26E+02 1.28E+02883 1.27E+02 1.30E+02 1.30E+02 1.26E+02 1.25E+02 1.26E+02 1.25E+02885 1.29E+02 1.27E+02 1.27E+02 1.28E+02 1.26E+02 1.28E+02 1.27E+02886 1.25E+02 1.26E+02 1.26E+02 1.30E+02 1.24E+02 1.25E+02 1.24E+02887 1.28E+02 1.27E+02 1.28E+02 1.30E+02 1.27E+02 1.28E+02 1.23E+02891 1.27E+02 1.27E+02 1.27E+02 1.26E+02 1.26E+02 1.28E+02 1.26E+02892 1.26E+02 1.29E+02 1.28E+02 1.26E+02 1.26E+02 1.30E+02 1.32E+02895 1.28E+02 1.28E+02 1.28E+02 1.27E+02 1.28E+02 1.26E+02 1.27E+02896 1.24E+02 1.27E+02 1.28E+02 1.29E+02 1.28E+02 1.27E+02 1.26E+02

Biased StatisticsAverage Biased 1.27E+02 1.27E+02 1.27E+02 1.26E+02 1.25E+02 1.26E+02 1.26E+02Std Dev Biased 1.59E+00 1.93E+00 2.42E+00 1.81E+00 8.14E-01 1.42E+00 1.81E+00Ps90%/90% (+KTL) Biased 1.32E+02 1.32E+02 1.34E+02 1.30E+02 1.27E+02 1.30E+02 1.31E+02Ps90%/90% (-KTL) Biased 1.23E+02 1.22E+02 1.20E+02 1.21E+02 1.23E+02 1.22E+02 1.21E+02Un-Biased StatisticsAverage Un-Biased 1.27E+02 1.27E+02 1.27E+02 1.28E+02 1.26E+02 1.27E+02 1.27E+02Std Dev Un-Biased 1.33E+00 1.06E+00 1.12E+00 2.23E+00 1.54E+00 1.93E+00 3.53E+00Ps90%/90% (+KTL) Un-Biased 1.31E+02 1.30E+02 1.30E+02 1.34E+02 1.30E+02 1.32E+02 1.36E+02Ps90%/90% (-KTL) Un-Biased 1.23E+02 1.24E+02 1.24E+02 1.22E+02 1.22E+02 1.22E+02 1.17E+02Specification MIN 1.16E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 457: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

457

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

5V

#1 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.225. Plot of Common Mode Rejection Ratio @ 5V #1 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 458: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

458

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.225. Raw data for Common Mode Rejection Ratio @ 5V #1 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 5V #1 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 8.30E+01 8.32E+01 8.32E+01 8.33E+01 8.33E+01 8.34E+01 8.29E+01879 8.98E+01 8.94E+01 8.93E+01 8.90E+01 8.86E+01 8.88E+01 8.87E+01882 8.16E+01 8.15E+01 8.15E+01 8.14E+01 8.14E+01 8.16E+01 8.10E+01883 8.41E+01 8.42E+01 8.41E+01 8.41E+01 8.40E+01 8.41E+01 8.36E+01885 8.36E+01 8.39E+01 8.40E+01 8.37E+01 8.39E+01 8.40E+01 8.39E+01886 9.23E+01 9.26E+01 9.27E+01 9.29E+01 9.30E+01 9.30E+01 9.28E+01887 7.83E+01 7.82E+01 7.82E+01 7.81E+01 7.81E+01 7.81E+01 7.82E+01891 8.38E+01 8.37E+01 8.36E+01 8.36E+01 8.36E+01 8.36E+01 8.38E+01892 9.24E+01 9.23E+01 9.22E+01 9.19E+01 9.17E+01 9.18E+01 9.16E+01895 8.72E+01 8.73E+01 8.72E+01 8.72E+01 8.71E+01 8.72E+01 8.68E+01896 8.74E+01 8.74E+01 8.74E+01 8.74E+01 8.74E+01 8.74E+01 8.74E+01

Biased StatisticsAverage Biased 8.44E+01 8.44E+01 8.44E+01 8.43E+01 8.42E+01 8.44E+01 8.40E+01Std Dev Biased 3.15E+00 2.95E+00 2.90E+00 2.81E+00 2.64E+00 2.67E+00 2.84E+00Ps90%/90% (+KTL) Biased 9.31E+01 9.25E+01 9.24E+01 9.20E+01 9.15E+01 9.17E+01 9.18E+01Ps90%/90% (-KTL) Biased 7.58E+01 7.64E+01 7.65E+01 7.66E+01 7.70E+01 7.71E+01 7.62E+01Un-Biased StatisticsAverage Un-Biased 8.68E+01 8.68E+01 8.68E+01 8.68E+01 8.67E+01 8.67E+01 8.67E+01Std Dev Un-Biased 6.01E+00 6.07E+00 6.11E+00 6.11E+00 6.09E+00 6.13E+00 5.98E+00Ps90%/90% (+KTL) Un-Biased 1.03E+02 1.03E+02 1.04E+02 1.04E+02 1.03E+02 1.04E+02 1.03E+02Ps90%/90% (-KTL) Un-Biased 7.03E+01 7.02E+01 7.00E+01 7.00E+01 7.00E+01 6.99E+01 7.03E+01Specification MIN 7.60E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL PASS PASS PASS FAIL FAIL PASS

Total Dose (krad(Si))

Page 459: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

459

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

5V

#2 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.226. Plot of Common Mode Rejection Ratio @ 5V #2 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 460: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

460

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.226. Raw data for Common Mode Rejection Ratio @ 5V #2 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 5V #2 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 8.01E+01 8.00E+01 8.01E+01 8.01E+01 8.03E+01 8.00E+01 7.95E+01879 8.91E+01 8.87E+01 8.86E+01 8.85E+01 8.80E+01 8.82E+01 8.78E+01882 8.96E+01 8.90E+01 8.87E+01 8.86E+01 8.85E+01 8.87E+01 8.81E+01883 9.05E+01 9.02E+01 9.01E+01 9.00E+01 8.97E+01 9.11E+01 8.92E+01885 8.92E+01 8.90E+01 8.88E+01 8.84E+01 8.83E+01 8.85E+01 8.79E+01886 1.30E+02 1.19E+02 1.14E+02 1.13E+02 1.10E+02 1.11E+02 1.20E+02887 8.32E+01 8.30E+01 8.29E+01 8.28E+01 8.27E+01 8.26E+01 8.28E+01891 1.07E+02 1.05E+02 1.04E+02 1.02E+02 1.01E+02 1.01E+02 1.06E+02892 9.77E+01 9.83E+01 9.87E+01 9.93E+01 9.97E+01 1.00E+02 9.95E+01895 9.41E+01 9.40E+01 9.39E+01 9.37E+01 9.35E+01 9.38E+01 9.31E+01896 9.61E+01 9.60E+01 9.59E+01 9.59E+01 9.59E+01 9.60E+01 9.59E+01

Biased StatisticsAverage Biased 8.77E+01 8.74E+01 8.73E+01 8.71E+01 8.69E+01 8.73E+01 8.65E+01Std Dev Biased 4.30E+00 4.16E+00 4.06E+00 3.96E+00 3.80E+00 4.24E+00 3.96E+00Ps90%/90% (+KTL) Biased 9.95E+01 9.88E+01 9.84E+01 9.80E+01 9.73E+01 9.89E+01 9.73E+01Ps90%/90% (-KTL) Biased 7.59E+01 7.60E+01 7.61E+01 7.63E+01 7.65E+01 7.57E+01 7.56E+01Un-Biased StatisticsAverage Un-Biased 1.02E+02 9.98E+01 9.87E+01 9.83E+01 9.74E+01 9.77E+01 1.00E+02Std Dev Un-Biased 1.77E+01 1.32E+01 1.16E+01 1.12E+01 1.02E+01 1.04E+01 1.38E+01Ps90%/90% (+KTL) Un-Biased 1.51E+02 1.36E+02 1.30E+02 1.29E+02 1.25E+02 1.26E+02 1.38E+02Ps90%/90% (-KTL) Un-Biased 5.40E+01 6.35E+01 6.69E+01 6.76E+01 6.94E+01 6.91E+01 6.23E+01Specification MIN 7.60E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 461: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

461

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

5V

#3 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.227. Plot of Common Mode Rejection Ratio @ 5V #3 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 462: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

462

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.227. Raw data for Common Mode Rejection Ratio @ 5V #3 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 5V #3 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.09E+01 9.14E+01 9.16E+01 9.16E+01 9.19E+01 9.17E+01 9.26E+01879 8.64E+01 8.60E+01 8.58E+01 8.57E+01 8.52E+01 8.54E+01 8.50E+01882 8.67E+01 8.63E+01 8.65E+01 8.65E+01 8.66E+01 8.66E+01 8.61E+01883 8.87E+01 8.84E+01 8.84E+01 8.81E+01 8.80E+01 8.82E+01 8.69E+01885 8.54E+01 8.57E+01 8.57E+01 8.53E+01 8.57E+01 8.58E+01 8.47E+01886 8.42E+01 8.41E+01 8.40E+01 8.40E+01 8.40E+01 8.40E+01 8.41E+01887 1.03E+02 1.06E+02 1.07E+02 1.08E+02 1.14E+02 1.13E+02 1.04E+02891 8.25E+01 8.25E+01 8.24E+01 8.24E+01 8.23E+01 8.24E+01 8.23E+01892 8.57E+01 8.57E+01 8.56E+01 8.55E+01 8.52E+01 8.53E+01 8.54E+01895 9.14E+01 9.13E+01 9.13E+01 9.13E+01 9.13E+01 9.12E+01 9.17E+01896 8.90E+01 8.90E+01 8.90E+01 8.89E+01 8.90E+01 8.90E+01 8.89E+01

Biased StatisticsAverage Biased 8.76E+01 8.76E+01 8.76E+01 8.74E+01 8.75E+01 8.75E+01 8.71E+01Std Dev Biased 2.20E+00 2.40E+00 2.45E+00 2.57E+00 2.70E+00 2.53E+00 3.24E+00Ps90%/90% (+KTL) Biased 9.36E+01 9.42E+01 9.43E+01 9.45E+01 9.49E+01 9.45E+01 9.59E+01Ps90%/90% (-KTL) Biased 8.16E+01 8.10E+01 8.09E+01 8.04E+01 8.01E+01 8.06E+01 7.82E+01Un-Biased StatisticsAverage Un-Biased 8.95E+01 9.00E+01 9.00E+01 9.03E+01 9.13E+01 9.12E+01 8.95E+01Std Dev Un-Biased 8.50E+00 9.76E+00 9.86E+00 1.07E+01 1.30E+01 1.28E+01 8.83E+00Ps90%/90% (+KTL) Un-Biased 1.13E+02 1.17E+02 1.17E+02 1.20E+02 1.27E+02 1.26E+02 1.14E+02Ps90%/90% (-KTL) Un-Biased 6.61E+01 6.32E+01 6.29E+01 6.10E+01 5.57E+01 5.62E+01 6.53E+01Specification MIN 7.60E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 463: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

463

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io @

5V

#4 (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.228. Plot of Common Mode Rejection Ratio @ 5V #4 (dB) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 464: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

464

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.228. Raw data for Common Mode Rejection Ratio @ 5V #4 (dB) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Common Mode Rejection Ratio @ 5V #4 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 8.17E+01 8.16E+01 8.16E+01 8.16E+01 8.16E+01 8.17E+01 8.15E+01879 1.31E+02 1.14E+02 1.11E+02 1.09E+02 1.06E+02 1.07E+02 1.04E+02882 8.68E+01 8.63E+01 8.65E+01 8.64E+01 8.63E+01 8.64E+01 8.57E+01883 9.62E+01 9.58E+01 9.55E+01 9.54E+01 9.48E+01 9.53E+01 9.32E+01885 9.81E+01 9.77E+01 9.74E+01 9.65E+01 9.65E+01 9.68E+01 9.44E+01886 1.20E+02 1.13E+02 1.11E+02 1.09E+02 1.06E+02 1.06E+02 1.08E+02887 8.73E+01 8.72E+01 8.71E+01 8.70E+01 8.69E+01 8.70E+01 8.68E+01891 1.08E+02 1.07E+02 1.05E+02 1.03E+02 1.01E+02 1.02E+02 1.04E+02892 9.41E+01 9.48E+01 9.55E+01 9.55E+01 9.64E+01 9.63E+01 9.50E+01895 8.70E+01 8.68E+01 8.67E+01 8.66E+01 8.64E+01 8.65E+01 8.68E+01896 1.04E+02 1.04E+02 1.03E+02 1.03E+02 1.04E+02 1.03E+02 1.03E+02

Biased StatisticsAverage Biased 9.86E+01 9.51E+01 9.43E+01 9.38E+01 9.30E+01 9.35E+01 9.18E+01Std Dev Biased 1.91E+01 1.26E+01 1.12E+01 1.07E+01 9.41E+00 9.89E+00 8.69E+00Ps90%/90% (+KTL) Biased 1.51E+02 1.30E+02 1.25E+02 1.23E+02 1.19E+02 1.21E+02 1.16E+02Ps90%/90% (-KTL) Biased 4.64E+01 6.05E+01 6.37E+01 6.46E+01 6.72E+01 6.63E+01 6.80E+01Un-Biased StatisticsAverage Un-Biased 9.93E+01 9.77E+01 9.71E+01 9.62E+01 9.54E+01 9.56E+01 9.63E+01Std Dev Un-Biased 1.44E+01 1.19E+01 1.09E+01 9.79E+00 8.77E+00 8.82E+00 9.90E+00Ps90%/90% (+KTL) Un-Biased 1.39E+02 1.30E+02 1.27E+02 1.23E+02 1.19E+02 1.20E+02 1.23E+02Ps90%/90% (-KTL) Un-Biased 5.98E+01 6.53E+01 6.72E+01 6.93E+01 7.14E+01 7.14E+01 6.91E+01Specification MIN 7.60E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 465: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

465

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

1.10E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

1-4

@ 5

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.229. Plot of Common Mode Rejection Ratio Matching 1-4 @ 5V (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 466: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

466

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.229. Raw data for Common Mode Rejection Ratio Matching 1-4 @ 5V (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Common Mode Rejection Ratio Matching 1-4 @ 5V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 9.84E+01 9.67E+01 9.68E+01 9.66E+01 9.64E+01 9.65E+01 9.83E+01879 8.97E+01 8.99E+01 9.01E+01 8.98E+01 8.99E+01 8.99E+01 9.03E+01882 8.85E+01 8.90E+01 8.87E+01 8.86E+01 8.88E+01 8.90E+01 8.86E+01883 8.66E+01 8.68E+01 8.68E+01 8.68E+01 8.69E+01 8.70E+01 8.71E+01885 8.55E+01 8.59E+01 8.61E+01 8.59E+01 8.62E+01 8.62E+01 8.70E+01886 9.20E+01 9.18E+01 9.18E+01 9.16E+01 9.13E+01 9.14E+01 9.15E+01887 8.21E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.22E+01891 8.43E+01 8.44E+01 8.44E+01 8.46E+01 8.48E+01 8.47E+01 8.46E+01892 8.72E+01 8.74E+01 8.77E+01 8.75E+01 8.77E+01 8.78E+01 8.71E+01895 1.18E+02 1.13E+02 1.11E+02 1.09E+02 1.08E+02 1.09E+02 1.40E+02896 8.87E+01 8.89E+01 8.89E+01 8.89E+01 8.88E+01 8.90E+01 8.89E+01

Biased StatisticsAverage Biased 8.97E+01 8.97E+01 8.97E+01 8.96E+01 8.96E+01 8.97E+01 9.03E+01Std Dev Biased 5.09E+00 4.27E+00 4.25E+00 4.22E+00 4.05E+00 4.05E+00 4.68E+00Ps90%/90% (+KTL) Biased 1.04E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.03E+02Ps90%/90% (-KTL) Biased 7.58E+01 7.80E+01 7.80E+01 7.80E+01 7.85E+01 7.86E+01 7.74E+01Un-Biased StatisticsAverage Un-Biased 9.27E+01 9.18E+01 9.14E+01 9.10E+01 9.08E+01 9.09E+01 9.70E+01Std Dev Un-Biased 1.46E+01 1.25E+01 1.16E+01 1.09E+01 1.04E+01 1.05E+01 2.41E+01Ps90%/90% (+KTL) Un-Biased 1.33E+02 1.26E+02 1.23E+02 1.21E+02 1.19E+02 1.20E+02 1.63E+02Ps90%/90% (-KTL) Un-Biased 5.27E+01 5.75E+01 5.95E+01 6.11E+01 6.23E+01 6.20E+01 3.09E+01Specification MIN 7.50E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 467: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

467

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

3.00E+01

4.00E+01

5.00E+01

6.00E+01

7.00E+01

8.00E+01

9.00E+01

1.00E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Com

mon

Mod

e R

ejec

tion

Rat

io M

atch

ing

2-3

@ 5

V (d

B)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.230. Plot of Common Mode Rejection Ratio Matching 2-3 @ 5V (dB) versus total dose. The datashow no significant change with radiation. The solid diamonds are the average of the measured data points forthe sample irradiated under electrical bias while the shaded diamonds are the average of the measured datapoints for the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the sample irradiated under electrical biaswhile the gray lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 468: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

468

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.230. Raw data for Common Mode Rejection Ratio Matching 2-3 @ 5V (dB) versustotal dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Common Mode Rejection Ratio Matching 2-3 @ 5V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.79E+01 7.80E+01 7.80E+01 7.81E+01 7.82E+01 7.80E+01 7.78E+01879 9.79E+01 9.75E+01 9.70E+01 9.67E+01 9.65E+01 9.66E+01 9.61E+01882 9.76E+01 9.78E+01 9.95E+01 1.00E+02 1.01E+02 1.00E+02 1.00E+02883 1.03E+02 1.03E+02 1.03E+02 1.02E+02 1.03E+02 9.90E+01 9.96E+01885 9.44E+01 9.55E+01 9.64E+01 9.60E+01 9.75E+01 9.74E+01 9.50E+01886 8.42E+01 8.43E+01 8.43E+01 8.44E+01 8.44E+01 8.44E+01 8.39E+01887 8.24E+01 8.24E+01 8.23E+01 8.24E+01 8.24E+01 8.24E+01 8.20E+01891 8.30E+01 8.32E+01 8.32E+01 8.33E+01 8.35E+01 8.34E+01 8.29E+01892 8.38E+01 8.39E+01 8.39E+01 8.39E+01 8.37E+01 8.38E+01 8.39E+01895 1.03E+02 1.03E+02 1.03E+02 1.04E+02 1.04E+02 1.03E+02 1.08E+02896 9.40E+01 9.42E+01 9.42E+01 9.41E+01 9.42E+01 9.41E+01 9.41E+01

Biased StatisticsAverage Biased 9.42E+01 9.44E+01 9.48E+01 9.46E+01 9.52E+01 9.42E+01 9.37E+01Std Dev Biased 9.60E+00 9.57E+00 9.78E+00 9.58E+00 9.81E+00 9.19E+00 9.17E+00Ps90%/90% (+KTL) Biased 1.21E+02 1.21E+02 1.22E+02 1.21E+02 1.22E+02 1.19E+02 1.19E+02Ps90%/90% (-KTL) Biased 6.78E+01 6.81E+01 6.80E+01 6.83E+01 6.83E+01 6.90E+01 6.85E+01Un-Biased StatisticsAverage Un-Biased 8.72E+01 8.73E+01 8.74E+01 8.75E+01 8.77E+01 8.74E+01 8.82E+01Std Dev Un-Biased 8.72E+00 8.67E+00 8.81E+00 9.02E+00 9.28E+00 8.79E+00 1.12E+01Ps90%/90% (+KTL) Un-Biased 1.11E+02 1.11E+02 1.12E+02 1.12E+02 1.13E+02 1.12E+02 1.19E+02Ps90%/90% (-KTL) Un-Biased 6.33E+01 6.35E+01 6.32E+01 6.28E+01 6.22E+01 6.33E+01 5.74E+01Specification MIN 7.50E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01 7.00E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 469: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

469

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E+01

-6.00E+01

-4.00E+01

-2.00E+01

0.00E+00

2.00E+01

4.00E+01

6.00E+01

8.00E+01

1.00E+02

1.20E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

2.2

V-12

V #1

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.231. Plot of Power Supply Rejection Ratio @ 2.2V-12V #1 (dB) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 470: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

470

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.231. Raw data for Power Supply Rejection Ratio @ 2.2V-12V #1 (dB) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Power Supply Rejection Ratio @ 2.2V-12V #1 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.13E+02 1.13E+02 1.13E+02 1.12E+02 1.07E+02 1.09E+02 1.12E+02879 9.99E+01 1.00E+02 1.00E+02 1.00E+02 1.00E+02 1.01E+02 1.01E+02882 1.05E+02 1.05E+02 1.06E+02 1.05E+02 1.78E+01 1.03E+02 1.05E+02883 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.69E+01 1.01E+02 1.03E+02885 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.04E+02 1.04E+02 1.05E+02886 1.06E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02887 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.08E+02 1.08E+02891 1.04E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.04E+02892 1.16E+02 1.16E+02 1.15E+02 1.16E+02 1.16E+02 1.12E+02 1.12E+02895 1.05E+02 1.05E+02 1.05E+02 1.06E+02 1.06E+02 1.06E+02 1.06E+02896 1.14E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.10E+02 1.10E+02

Biased StatisticsAverage Biased 1.05E+02 1.05E+02 1.05E+02 1.05E+02 6.92E+01 1.03E+02 1.05E+02Std Dev Biased 4.71E+00 4.87E+00 4.85E+00 4.60E+00 4.74E+01 3.19E+00 4.29E+00Ps90%/90% (+KTL) Biased 1.18E+02 1.19E+02 1.19E+02 1.18E+02 1.99E+02 1.12E+02 1.17E+02Ps90%/90% (-KTL) Biased 9.21E+01 9.19E+01 9.20E+01 9.24E+01 ######## 9.47E+01 9.32E+01Un-Biased StatisticsAverage Un-Biased 1.08E+02 1.09E+02 1.08E+02 1.09E+02 1.09E+02 1.07E+02 1.07E+02Std Dev Un-Biased 4.65E+00 4.58E+00 4.43E+00 4.49E+00 4.51E+00 2.82E+00 2.75E+00Ps90%/90% (+KTL) Un-Biased 1.21E+02 1.21E+02 1.21E+02 1.21E+02 1.21E+02 1.15E+02 1.15E+02Ps90%/90% (-KTL) Un-Biased 9.56E+01 9.60E+01 9.63E+01 9.62E+01 9.63E+01 9.97E+01 9.97E+01Specification MIN 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01Status PASS PASS PASS PASS FAIL PASS PASS

Total Dose (krad(Si))

Page 471: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

471

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-1.00E+02

-5.00E+01

0.00E+00

5.00E+01

1.00E+02

1.50E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

2.2

V-12

V #2

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.232. Plot of Power Supply Rejection Ratio @ 2.2V-12V #2 (dB) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 472: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

472

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.232. Raw data for Power Supply Rejection Ratio @ 2.2V-12V #2 (dB) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Power Supply Rejection Ratio @ 2.2V-12V #2 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.01E+02 1.01E+02 1.01E+02 1.01E+02 9.93E+01 9.97E+01 1.01E+02879 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.06E+02 1.06E+02 1.06E+02882 1.04E+02 1.05E+02 1.05E+02 1.04E+02 1.79E+01 1.02E+02 1.04E+02883 1.22E+02 1.23E+02 1.24E+02 1.25E+02 1.61E+01 1.75E+01 1.18E+02885 1.23E+02 1.22E+02 1.22E+02 1.22E+02 1.25E+02 1.40E+02 1.36E+02886 1.34E+02 1.42E+02 1.46E+02 1.47E+02 1.38E+02 1.59E+02 1.42E+02887 1.16E+02 1.16E+02 1.18E+02 1.18E+02 1.19E+02 1.15E+02 1.14E+02891 1.08E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02892 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02895 1.05E+02 1.05E+02 1.05E+02 1.06E+02 1.05E+02 1.05E+02 1.05E+02896 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.01E+02 1.01E+02

Biased StatisticsAverage Biased 1.11E+02 1.11E+02 1.11E+02 1.11E+02 7.28E+01 9.31E+01 1.13E+02Std Dev Biased 1.05E+01 1.04E+01 1.06E+01 1.12E+01 5.18E+01 4.54E+01 1.43E+01Ps90%/90% (+KTL) Biased 1.40E+02 1.40E+02 1.41E+02 1.42E+02 2.15E+02 2.18E+02 1.52E+02Ps90%/90% (-KTL) Biased 8.23E+01 8.27E+01 8.23E+01 8.08E+01 -6.92E+01 -3.13E+01 7.36E+01Un-Biased StatisticsAverage Un-Biased 1.13E+02 1.15E+02 1.16E+02 1.16E+02 1.15E+02 1.18E+02 1.14E+02Std Dev Un-Biased 1.30E+01 1.59E+01 1.78E+01 1.81E+01 1.44E+01 2.32E+01 1.59E+01Ps90%/90% (+KTL) Un-Biased 1.49E+02 1.58E+02 1.65E+02 1.66E+02 1.54E+02 1.82E+02 1.58E+02Ps90%/90% (-KTL) Un-Biased 7.76E+01 7.12E+01 6.72E+01 6.65E+01 7.54E+01 5.44E+01 7.05E+01Specification MIN 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 473: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

473

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E+01

-2.00E+01

0.00E+00

2.00E+01

4.00E+01

6.00E+01

8.00E+01

1.00E+02

1.20E+02

1.40E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

2.2

V-12

V #3

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.233. Plot of Power Supply Rejection Ratio @ 2.2V-12V #3 (dB) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 474: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

474

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.233. Raw data for Power Supply Rejection Ratio @ 2.2V-12V #3 (dB) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Power Supply Rejection Ratio @ 2.2V-12V #3 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.06E+02 1.07E+02 1.07E+02 1.07E+02 1.06E+02 1.05E+02 1.05E+02879 1.06E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.08E+02 1.07E+02882 1.03E+02 1.03E+02 1.03E+02 1.02E+02 2.05E+01 1.01E+02 1.03E+02883 1.05E+02 1.06E+02 1.06E+02 1.06E+02 7.84E+01 7.85E+01 1.06E+02885 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.05E+02 1.06E+02 1.07E+02886 1.37E+02 1.35E+02 1.38E+02 1.44E+02 1.45E+02 1.19E+02 1.19E+02887 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.05E+02891 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02892 1.26E+02 1.25E+02 1.24E+02 1.24E+02 1.24E+02 1.34E+02 1.34E+02895 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02 1.04E+02896 1.08E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02

Biased StatisticsAverage Biased 1.05E+02 1.06E+02 1.06E+02 1.06E+02 8.35E+01 9.96E+01 1.06E+02Std Dev Biased 1.56E+00 1.62E+00 1.63E+00 1.90E+00 3.72E+01 1.20E+01 1.90E+00Ps90%/90% (+KTL) Biased 1.10E+02 1.10E+02 1.10E+02 1.11E+02 1.86E+02 1.33E+02 1.11E+02Ps90%/90% (-KTL) Biased 1.01E+02 1.01E+02 1.01E+02 1.00E+02 ######## 6.66E+01 1.00E+02Un-Biased StatisticsAverage Un-Biased 1.15E+02 1.15E+02 1.15E+02 1.16E+02 1.17E+02 1.13E+02 1.13E+02Std Dev Un-Biased 1.57E+01 1.46E+01 1.56E+01 1.76E+01 1.81E+01 1.34E+01 1.32E+01Ps90%/90% (+KTL) Un-Biased 1.58E+02 1.55E+02 1.58E+02 1.65E+02 1.66E+02 1.50E+02 1.49E+02Ps90%/90% (-KTL) Un-Biased 7.21E+01 7.45E+01 7.23E+01 6.79E+01 6.71E+01 7.66E+01 7.69E+01Specification MIN 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 475: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

475

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-4.00E+01

-2.00E+01

0.00E+00

2.00E+01

4.00E+01

6.00E+01

8.00E+01

1.00E+02

1.20E+02

1.40E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io @

2.2

V-12

V #4

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.234. Plot of Power Supply Rejection Ratio @ 2.2V-12V #4 (dB) versus total dose. The data show asignificant change with radiation causing a failure at the 50krad(Si) dose level. The solid diamonds are theaverage of the measured data points for the sample irradiated under electrical bias while the shaded diamondsare the average of the measured data points for the units irradiated with all pins tied to ground. The black lines(solid and/or dashed) are the average of the data points after application of the KTL statistics on the sampleirradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points afterapplication of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) arethe pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheetand/or test plan.

Page 476: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

476

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.234. Raw data for Power Supply Rejection Ratio @ 2.2V-12V #4 (dB) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Power Supply Rejection Ratio @ 2.2V-12V #4 (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.19E+02 1.20E+02 1.20E+02 1.19E+02 1.10E+02 1.12E+02 1.18E+02879 9.85E+01 9.88E+01 9.87E+01 9.87E+01 9.88E+01 9.91E+01 9.91E+01882 1.68E+02 1.46E+02 1.42E+02 1.48E+02 1.76E+01 1.20E+02 1.22E+02883 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.06E+02 1.07E+02 1.07E+02885 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.06E+02 1.06E+02886 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02887 1.10E+02 1.10E+02 1.11E+02 1.10E+02 1.11E+02 1.08E+02 1.08E+02891 1.17E+02 1.17E+02 1.18E+02 1.18E+02 1.18E+02 1.17E+02 1.16E+02892 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.06E+02 1.04E+02 1.04E+02895 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02896 1.24E+02 1.24E+02 1.22E+02 1.26E+02 1.24E+02 1.15E+02 1.15E+02

Biased StatisticsAverage Biased 1.20E+02 1.16E+02 1.15E+02 1.16E+02 8.79E+01 1.09E+02 1.10E+02Std Dev Biased 2.79E+01 1.82E+01 1.69E+01 1.90E+01 3.95E+01 7.87E+00 9.46E+00Ps90%/90% (+KTL) Biased 1.97E+02 1.66E+02 1.62E+02 1.68E+02 1.96E+02 1.30E+02 1.36E+02Ps90%/90% (-KTL) Biased 4.37E+01 6.59E+01 6.90E+01 6.41E+01 -2.05E+01 8.72E+01 8.43E+01Un-Biased StatisticsAverage Un-Biased 1.08E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 1.08E+02 1.07E+02Std Dev Un-Biased 5.52E+00 5.65E+00 5.72E+00 5.79E+00 5.89E+00 5.46E+00 5.45E+00Ps90%/90% (+KTL) Un-Biased 1.23E+02 1.24E+02 1.24E+02 1.25E+02 1.25E+02 1.23E+02 1.22E+02Ps90%/90% (-KTL) Un-Biased 9.32E+01 9.31E+01 9.30E+01 9.29E+01 9.28E+01 9.26E+01 9.25E+01Specification MIN 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01 8.80E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 477: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

477

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-6.00E+01

-4.00E+01

-2.00E+01

0.00E+00

2.00E+01

4.00E+01

6.00E+01

8.00E+01

1.00E+02

1.20E+02

1.40E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io M

atch

ing

1-4

@ 2

.2V-

12V

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.235. Plot of Power Supply Rejection Ratio Matching 1-4 @ 2.2V-12V (dB) versus total dose. Thedata show a significant change with radiation causing a failure at the 50krad(Si) dose level. The soliddiamonds are the average of the measured data points for the sample irradiated under electrical bias while theshaded diamonds are the average of the measured data points for the units irradiated with all pins tied toground. The black lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 478: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

478

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.235. Raw data for Power Supply Rejection Ratio Matching 1-4 @ 2.2V-12V (dB)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio Matching 1-4 @ 2.2V-12V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.19E+02 1.19E+02 1.18E+02879 1.15E+02 1.16E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02882 1.05E+02 1.05E+02 1.05E+02 1.05E+02 4.93E+01 1.04E+02 1.06E+02883 1.10E+02 1.09E+02 1.09E+02 1.09E+02 1.69E+01 1.07E+02 1.11E+02885 1.18E+02 1.18E+02 1.17E+02 1.18E+02 1.14E+02 1.19E+02 1.25E+02886 1.37E+02 1.34E+02 1.61E+02 1.33E+02 1.38E+02 1.51E+02 1.58E+02887 1.41E+02 1.36E+02 1.33E+02 1.40E+02 1.36E+02 1.42E+02 1.47E+02891 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02892 1.08E+02 1.08E+02 1.09E+02 1.09E+02 1.09E+02 1.08E+02 1.08E+02895 1.15E+02 1.14E+02 1.14E+02 1.14E+02 1.15E+02 1.13E+02 1.12E+02896 1.17E+02 1.16E+02 1.18E+02 1.16E+02 1.17E+02 1.17E+02 1.16E+02

Biased StatisticsAverage Biased 1.13E+02 1.13E+02 1.13E+02 1.13E+02 8.29E+01 1.13E+02 1.15E+02Std Dev Biased 5.77E+00 5.79E+00 5.48E+00 5.95E+00 4.69E+01 6.73E+00 7.14E+00Ps90%/90% (+KTL) Biased 1.29E+02 1.29E+02 1.28E+02 1.29E+02 2.11E+02 1.31E+02 1.35E+02Ps90%/90% (-KTL) Biased 9.74E+01 9.75E+01 9.81E+01 9.68E+01 -4.57E+01 9.44E+01 9.57E+01Un-Biased StatisticsAverage Un-Biased 1.22E+02 1.20E+02 1.25E+02 1.21E+02 1.21E+02 1.24E+02 1.27E+02Std Dev Un-Biased 1.63E+01 1.42E+01 2.27E+01 1.51E+01 1.50E+01 2.06E+01 2.40E+01Ps90%/90% (+KTL) Un-Biased 1.66E+02 1.59E+02 1.87E+02 1.62E+02 1.62E+02 1.81E+02 1.92E+02Ps90%/90% (-KTL) Un-Biased 7.70E+01 8.12E+01 6.25E+01 7.91E+01 7.97E+01 6.77E+01 6.08E+01Specification MIN 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01Status FAIL FAIL FAIL FAIL FAIL FAIL FAIL

Total Dose (krad(Si))

Page 479: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

479

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-8.00E+01

-6.00E+01

-4.00E+01

-2.00E+01

0.00E+00

2.00E+01

4.00E+01

6.00E+01

8.00E+01

1.00E+02

1.20E+02

1.40E+02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Pow

er S

uppl

y R

ejec

tion

Rat

io M

atch

ing

2-3

@ 2

.2V-

12V

(dB

)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.236. Plot of Power Supply Rejection Ratio Matching 2-3 @ 2.2V-12V (dB) versus total dose. Thedata show a significant change with radiation causing a failure at the 50krad(Si) dose level. The soliddiamonds are the average of the measured data points for the sample irradiated under electrical bias while theshaded diamonds are the average of the measured data points for the units irradiated with all pins tied toground. The black lines (solid and/or dashed) are the average of the data points after application of the KTLstatistics on the sample irradiated under electrical bias while the gray lines (solid and/or dashed) are theaverage of the data points after application of the KTL statistics on the samples irradiated in the unbiasedcondition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specificationvalue as defined in the datasheet and/or test plan.

Page 480: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

480

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.236. Raw data for Power Supply Rejection Ratio Matching 2-3 @ 2.2V-12V (dB)versus total dose, including the statistical analysis, specification and the status of the testing(pass/fail).

Power Supply Rejection Ratio Matching 2-3 @ 2.2V-12V (dB) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.08E+02 1.08E+02 1.08E+02 1.07E+02 1.05E+02 1.06E+02 1.09E+02879 1.22E+02 1.22E+02 1.22E+02 1.22E+02 1.21E+02 1.20E+02 1.20E+02882 1.18E+02 1.18E+02 1.18E+02 1.18E+02 2.96E+01 1.18E+02 1.17E+02883 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.61E+01 1.75E+01 1.09E+02885 1.05E+02 1.05E+02 1.05E+02 1.05E+02 1.04E+02 1.05E+02 1.07E+02886 1.45E+02 1.41E+02 1.43E+02 1.39E+02 1.35E+02 1.19E+02 1.20E+02887 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.08E+02 1.08E+02891 1.12E+02 1.12E+02 1.11E+02 1.12E+02 1.12E+02 1.11E+02 1.11E+02892 1.01E+02 1.01E+02 1.01E+02 1.01E+02 1.02E+02 1.03E+02 1.02E+02895 1.22E+02 1.24E+02 1.22E+02 1.22E+02 1.23E+02 1.23E+02 1.25E+02896 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.05E+02 1.05E+02

Biased StatisticsAverage Biased 1.12E+02 1.12E+02 1.12E+02 1.12E+02 7.51E+01 9.34E+01 1.12E+02Std Dev Biased 7.58E+00 7.45E+00 7.47E+00 7.45E+00 4.84E+01 4.30E+01 6.08E+00Ps90%/90% (+KTL) Biased 1.33E+02 1.33E+02 1.33E+02 1.32E+02 2.08E+02 2.11E+02 1.29E+02Ps90%/90% (-KTL) Biased 9.14E+01 9.17E+01 9.17E+01 9.14E+01 -5.77E+01 -2.44E+01 9.56E+01Un-Biased StatisticsAverage Un-Biased 1.17E+02 1.17E+02 1.17E+02 1.16E+02 1.16E+02 1.13E+02 1.13E+02Std Dev Un-Biased 1.72E+01 1.58E+01 1.63E+01 1.49E+01 1.32E+01 8.38E+00 9.09E+00Ps90%/90% (+KTL) Un-Biased 1.65E+02 1.60E+02 1.62E+02 1.57E+02 1.52E+02 1.36E+02 1.38E+02Ps90%/90% (-KTL) Un-Biased 7.02E+01 7.37E+01 7.21E+01 7.54E+01 7.92E+01 9.00E+01 8.84E+01Specification MIN 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01 8.20E+01Status FAIL FAIL FAIL FAIL FAIL FAIL PASS

Total Dose (krad(Si))

Page 481: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

481

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 5

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.237. Plot of Output Voltage Swing High IL= 0mA @ 5V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 482: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

482

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.237. Raw data for Output Voltage Swing High IL= 0mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.90E-03 3.96E-03 3.87E-03 3.97E-03 4.05E-03 4.07E-03 4.16E-03879 3.95E-03 4.10E-03 4.09E-03 4.17E-03 4.07E-03 4.03E-03 4.30E-03882 3.83E-03 4.10E-03 3.84E-03 4.05E-03 4.10E-03 4.08E-03 4.18E-03883 4.20E-03 3.96E-03 4.06E-03 4.29E-03 4.23E-03 4.13E-03 4.32E-03885 3.88E-03 3.98E-03 4.01E-03 4.11E-03 4.05E-03 4.12E-03 4.18E-03886 3.86E-03 3.88E-03 4.07E-03 4.09E-03 4.14E-03 4.13E-03 4.05E-03887 3.95E-03 3.96E-03 4.02E-03 3.95E-03 4.26E-03 4.15E-03 4.18E-03891 3.88E-03 3.91E-03 4.01E-03 4.21E-03 4.24E-03 4.15E-03 4.08E-03892 3.81E-03 3.88E-03 4.04E-03 4.00E-03 4.26E-03 4.18E-03 4.03E-03895 4.00E-03 4.05E-03 4.04E-03 4.17E-03 4.12E-03 4.27E-03 4.11E-03896 4.22E-03 4.23E-03 4.16E-03 4.19E-03 4.26E-03 4.32E-03 4.38E-03

Biased StatisticsAverage Biased 3.95E-03 4.02E-03 3.97E-03 4.12E-03 4.10E-03 4.09E-03 4.23E-03Std Dev Biased 1.45E-04 7.35E-05 1.13E-04 1.21E-04 7.55E-05 4.04E-05 7.56E-05Ps90%/90% (+KTL) Biased 4.35E-03 4.22E-03 4.28E-03 4.45E-03 4.31E-03 4.20E-03 4.44E-03Ps90%/90% (-KTL) Biased 3.55E-03 3.82E-03 3.66E-03 3.79E-03 3.89E-03 3.98E-03 4.02E-03Un-Biased StatisticsAverage Un-Biased 3.90E-03 3.94E-03 4.04E-03 4.08E-03 4.20E-03 4.18E-03 4.09E-03Std Dev Un-Biased 7.52E-05 7.16E-05 2.30E-05 1.10E-04 6.84E-05 5.55E-05 5.87E-05Ps90%/90% (+KTL) Un-Biased 4.11E-03 4.13E-03 4.10E-03 4.39E-03 4.39E-03 4.33E-03 4.25E-03Ps90%/90% (-KTL) Un-Biased 3.69E-03 3.74E-03 3.97E-03 3.78E-03 4.02E-03 4.02E-03 3.93E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 483: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

483

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 5

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.238. Plot of Output Voltage Swing High IL= 0mA @ 5V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 484: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

484

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.238. Raw data for Output Voltage Swing High IL= 0mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.18E-03 4.13E-03 3.91E-03 4.14E-03 4.14E-03 4.27E-03 4.16E-03879 3.71E-03 3.89E-03 3.86E-03 3.94E-03 3.78E-03 3.97E-03 4.16E-03882 4.01E-03 4.06E-03 4.06E-03 4.02E-03 4.27E-03 4.15E-03 4.20E-03883 3.88E-03 3.84E-03 4.04E-03 4.12E-03 4.17E-03 3.97E-03 4.15E-03885 3.88E-03 4.01E-03 4.06E-03 3.99E-03 4.12E-03 3.91E-03 4.05E-03886 4.03E-03 3.88E-03 4.06E-03 4.12E-03 4.07E-03 3.98E-03 3.96E-03887 3.78E-03 3.74E-03 3.86E-03 3.89E-03 4.09E-03 4.12E-03 3.93E-03891 3.90E-03 3.98E-03 3.96E-03 4.14E-03 4.22E-03 4.07E-03 4.05E-03892 3.91E-03 3.95E-03 4.02E-03 3.97E-03 4.17E-03 4.08E-03 3.98E-03895 3.86E-03 3.88E-03 3.92E-03 4.02E-03 4.17E-03 4.03E-03 4.06E-03896 3.98E-03 4.08E-03 3.89E-03 4.16E-03 4.09E-03 4.15E-03 4.10E-03

Biased StatisticsAverage Biased 3.93E-03 3.99E-03 3.99E-03 4.04E-03 4.10E-03 4.05E-03 4.14E-03Std Dev Biased 1.75E-04 1.20E-04 9.42E-05 8.56E-05 1.86E-04 1.51E-04 5.59E-05Ps90%/90% (+KTL) Biased 4.41E-03 4.31E-03 4.24E-03 4.28E-03 4.61E-03 4.47E-03 4.30E-03Ps90%/90% (-KTL) Biased 3.45E-03 3.66E-03 3.73E-03 3.81E-03 3.59E-03 3.64E-03 3.99E-03Un-Biased StatisticsAverage Un-Biased 3.90E-03 3.89E-03 3.96E-03 4.03E-03 4.14E-03 4.06E-03 4.00E-03Std Dev Un-Biased 9.07E-05 9.26E-05 7.92E-05 1.04E-04 6.23E-05 5.32E-05 5.68E-05Ps90%/90% (+KTL) Un-Biased 4.14E-03 4.14E-03 4.18E-03 4.31E-03 4.31E-03 4.20E-03 4.15E-03Ps90%/90% (-KTL) Un-Biased 3.65E-03 3.63E-03 3.75E-03 3.74E-03 3.97E-03 3.91E-03 3.84E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 485: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

485

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 5

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.239. Plot of Output Voltage Swing High IL= 0mA @ 5V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 486: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

486

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.239. Raw data for Output Voltage Swing High IL= 0mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.06E-03 4.08E-03 4.21E-03 4.12E-03 4.04E-03 4.12E-03 4.13E-03879 3.81E-03 3.91E-03 3.82E-03 3.94E-03 3.99E-03 4.07E-03 4.03E-03882 3.95E-03 4.00E-03 3.96E-03 3.94E-03 4.28E-03 4.13E-03 4.21E-03883 3.96E-03 4.13E-03 4.07E-03 4.04E-03 4.20E-03 4.00E-03 4.16E-03885 3.98E-03 4.00E-03 3.94E-03 4.09E-03 4.15E-03 4.12E-03 4.06E-03886 4.01E-03 3.91E-03 4.13E-03 4.12E-03 4.24E-03 4.07E-03 4.08E-03887 3.76E-03 3.78E-03 3.89E-03 3.97E-03 3.99E-03 3.91E-03 3.94E-03891 3.95E-03 3.95E-03 3.99E-03 3.92E-03 4.04E-03 3.95E-03 4.10E-03892 3.88E-03 3.93E-03 3.99E-03 4.12E-03 4.15E-03 3.95E-03 4.21E-03895 3.93E-03 3.93E-03 3.92E-03 4.14E-03 4.04E-03 4.20E-03 4.06E-03896 4.17E-03 4.00E-03 3.94E-03 4.05E-03 4.10E-03 4.15E-03 4.16E-03

Biased StatisticsAverage Biased 3.95E-03 4.02E-03 4.00E-03 4.03E-03 4.13E-03 4.09E-03 4.12E-03Std Dev Biased 9.04E-05 8.44E-05 1.47E-04 8.35E-05 1.18E-04 5.45E-05 7.33E-05Ps90%/90% (+KTL) Biased 4.20E-03 4.26E-03 4.40E-03 4.26E-03 4.45E-03 4.24E-03 4.32E-03Ps90%/90% (-KTL) Biased 3.70E-03 3.79E-03 3.60E-03 3.80E-03 3.81E-03 3.94E-03 3.92E-03Un-Biased StatisticsAverage Un-Biased 3.91E-03 3.90E-03 3.98E-03 4.05E-03 4.09E-03 4.02E-03 4.08E-03Std Dev Un-Biased 9.40E-05 6.86E-05 9.26E-05 1.01E-04 1.01E-04 1.19E-04 9.65E-05Ps90%/90% (+KTL) Un-Biased 4.16E-03 4.09E-03 4.24E-03 4.33E-03 4.37E-03 4.34E-03 4.34E-03Ps90%/90% (-KTL) Un-Biased 3.65E-03 3.71E-03 3.73E-03 3.78E-03 3.81E-03 3.69E-03 3.81E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 487: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

487

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-03

1.00E-02

1.50E-02

2.00E-02

2.50E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

0mA

@ 5

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.240. Plot of Output Voltage Swing High IL= 0mA @ 5V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 488: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

488

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.240. Raw data for Output Voltage Swing High IL= 0mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 0mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.90E-03 4.03E-03 4.11E-03 3.95E-03 4.07E-03 4.03E-03 4.10E-03879 3.91E-03 4.01E-03 3.96E-03 4.11E-03 4.05E-03 3.98E-03 4.23E-03882 4.00E-03 3.96E-03 4.07E-03 3.99E-03 4.10E-03 3.98E-03 4.05E-03883 4.10E-03 4.01E-03 4.04E-03 4.16E-03 4.27E-03 4.13E-03 4.32E-03885 4.18E-03 4.00E-03 3.99E-03 4.00E-03 4.09E-03 3.98E-03 4.13E-03886 3.79E-03 4.01E-03 3.92E-03 4.12E-03 4.17E-03 4.10E-03 4.08E-03887 3.96E-03 3.93E-03 3.91E-03 4.09E-03 4.15E-03 4.18E-03 4.16E-03891 3.95E-03 4.01E-03 4.16E-03 4.14E-03 4.19E-03 4.22E-03 4.11E-03892 4.00E-03 3.98E-03 3.94E-03 4.16E-03 4.19E-03 4.22E-03 4.28E-03895 4.00E-03 4.08E-03 4.19E-03 4.17E-03 4.15E-03 4.37E-03 4.23E-03896 4.30E-03 4.37E-03 4.28E-03 4.31E-03 4.27E-03 4.49E-03 4.33E-03

Biased StatisticsAverage Biased 4.02E-03 4.00E-03 4.03E-03 4.04E-03 4.12E-03 4.02E-03 4.17E-03Std Dev Biased 1.21E-04 2.59E-05 6.02E-05 8.87E-05 8.82E-05 6.52E-05 1.08E-04Ps90%/90% (+KTL) Biased 4.35E-03 4.07E-03 4.20E-03 4.29E-03 4.36E-03 4.20E-03 4.46E-03Ps90%/90% (-KTL) Biased 3.69E-03 3.93E-03 3.87E-03 3.80E-03 3.87E-03 3.84E-03 3.87E-03Un-Biased StatisticsAverage Un-Biased 3.94E-03 4.00E-03 4.02E-03 4.14E-03 4.17E-03 4.22E-03 4.17E-03Std Dev Un-Biased 8.69E-05 5.45E-05 1.39E-04 3.21E-05 2.00E-05 9.81E-05 8.29E-05Ps90%/90% (+KTL) Un-Biased 4.18E-03 4.15E-03 4.40E-03 4.22E-03 4.22E-03 4.49E-03 4.40E-03Ps90%/90% (-KTL) Un-Biased 3.70E-03 3.85E-03 3.64E-03 4.05E-03 4.12E-03 3.95E-03 3.94E-03Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 489: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

489

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 5

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.241. Plot of Output Voltage Swing High IL= 1mA @ 5V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 490: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

490

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.241. Raw data for Output Voltage Swing High IL= 1mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.88E-02 7.01E-02 7.07E-02 7.14E-02 7.21E-02 7.17E-02 7.15E-02879 6.91E-02 7.07E-02 7.09E-02 7.16E-02 7.16E-02 7.11E-02 7.09E-02882 6.79E-02 6.92E-02 7.01E-02 7.05E-02 7.12E-02 7.10E-02 7.07E-02883 7.10E-02 7.24E-02 7.33E-02 7.36E-02 7.46E-02 7.41E-02 7.42E-02885 6.98E-02 7.10E-02 7.18E-02 7.18E-02 7.29E-02 7.28E-02 7.24E-02886 6.84E-02 6.86E-02 6.92E-02 6.95E-02 6.99E-02 6.98E-02 6.94E-02887 6.92E-02 6.98E-02 7.04E-02 7.07E-02 7.12E-02 7.08E-02 7.07E-02891 6.90E-02 6.95E-02 7.03E-02 7.07E-02 7.12E-02 7.09E-02 7.06E-02892 6.83E-02 6.89E-02 6.93E-02 7.01E-02 7.07E-02 7.03E-02 6.99E-02895 7.07E-02 7.11E-02 7.17E-02 7.20E-02 7.29E-02 7.24E-02 7.19E-02896 7.23E-02 7.23E-02 7.22E-02 7.22E-02 7.23E-02 7.25E-02 7.25E-02

Biased StatisticsAverage Biased 6.93E-02 7.07E-02 7.14E-02 7.18E-02 7.25E-02 7.21E-02 7.19E-02Std Dev Biased 1.17E-03 1.17E-03 1.25E-03 1.14E-03 1.34E-03 1.32E-03 1.42E-03Ps90%/90% (+KTL) Biased 7.25E-02 7.39E-02 7.48E-02 7.49E-02 7.61E-02 7.57E-02 7.58E-02Ps90%/90% (-KTL) Biased 6.61E-02 6.75E-02 6.79E-02 6.86E-02 6.88E-02 6.85E-02 6.81E-02Un-Biased StatisticsAverage Un-Biased 6.91E-02 6.96E-02 7.02E-02 7.06E-02 7.12E-02 7.08E-02 7.05E-02Std Dev Un-Biased 9.59E-04 9.78E-04 1.01E-03 9.37E-04 1.06E-03 1.00E-03 9.61E-04Ps90%/90% (+KTL) Un-Biased 7.17E-02 7.23E-02 7.30E-02 7.32E-02 7.41E-02 7.36E-02 7.31E-02Ps90%/90% (-KTL) Un-Biased 6.65E-02 6.69E-02 6.74E-02 6.80E-02 6.83E-02 6.81E-02 6.79E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 491: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

491

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 5

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.242. Plot of Output Voltage Swing High IL= 1mA @ 5V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 492: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

492

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.242. Raw data for Output Voltage Swing High IL= 1mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.84E-02 6.95E-02 7.02E-02 7.09E-02 7.20E-02 7.16E-02 7.13E-02879 6.61E-02 6.74E-02 6.84E-02 6.88E-02 6.91E-02 6.84E-02 6.83E-02882 6.76E-02 6.87E-02 6.94E-02 7.02E-02 7.07E-02 7.02E-02 7.01E-02883 7.04E-02 7.19E-02 7.27E-02 7.32E-02 7.42E-02 7.36E-02 7.32E-02885 6.87E-02 7.07E-02 7.13E-02 7.12E-02 7.22E-02 7.18E-02 7.16E-02886 6.77E-02 6.78E-02 6.85E-02 6.87E-02 6.91E-02 6.89E-02 6.88E-02887 6.60E-02 6.66E-02 6.73E-02 6.77E-02 6.85E-02 6.82E-02 6.75E-02891 6.59E-02 6.66E-02 6.73E-02 6.74E-02 6.80E-02 6.77E-02 6.73E-02892 6.83E-02 6.83E-02 6.91E-02 6.93E-02 7.01E-02 6.97E-02 6.95E-02895 6.57E-02 6.58E-02 6.65E-02 6.70E-02 6.73E-02 6.71E-02 6.67E-02896 6.95E-02 6.94E-02 6.92E-02 6.94E-02 6.92E-02 6.91E-02 6.94E-02

Biased StatisticsAverage Biased 6.83E-02 6.96E-02 7.04E-02 7.09E-02 7.16E-02 7.11E-02 7.09E-02Std Dev Biased 1.56E-03 1.73E-03 1.66E-03 1.60E-03 1.91E-03 1.97E-03 1.84E-03Ps90%/90% (+KTL) Biased 7.25E-02 7.44E-02 7.49E-02 7.53E-02 7.68E-02 7.65E-02 7.59E-02Ps90%/90% (-KTL) Biased 6.40E-02 6.49E-02 6.59E-02 6.65E-02 6.64E-02 6.57E-02 6.58E-02Un-Biased StatisticsAverage Un-Biased 6.67E-02 6.70E-02 6.77E-02 6.80E-02 6.86E-02 6.83E-02 6.80E-02Std Dev Un-Biased 1.17E-03 1.02E-03 1.05E-03 9.35E-04 1.07E-03 1.02E-03 1.16E-03Ps90%/90% (+KTL) Un-Biased 6.99E-02 6.98E-02 7.06E-02 7.06E-02 7.15E-02 7.11E-02 7.11E-02Ps90%/90% (-KTL) Un-Biased 6.35E-02 6.42E-02 6.48E-02 6.54E-02 6.57E-02 6.55E-02 6.48E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 493: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

493

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 5

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.243. Plot of Output Voltage Swing High IL= 1mA @ 5V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 494: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

494

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.243. Raw data for Output Voltage Swing High IL= 1mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.85E-02 6.99E-02 7.02E-02 7.06E-02 7.15E-02 7.11E-02 7.11E-02879 6.59E-02 6.72E-02 6.83E-02 6.89E-02 6.88E-02 6.83E-02 6.82E-02882 6.72E-02 6.88E-02 6.94E-02 6.98E-02 7.06E-02 6.98E-02 6.99E-02883 7.02E-02 7.19E-02 7.28E-02 7.34E-02 7.42E-02 7.37E-02 7.35E-02885 6.90E-02 7.07E-02 7.14E-02 7.11E-02 7.25E-02 7.20E-02 7.17E-02886 6.75E-02 6.79E-02 6.82E-02 6.87E-02 6.92E-02 6.90E-02 6.87E-02887 6.59E-02 6.66E-02 6.70E-02 6.75E-02 6.83E-02 6.79E-02 6.74E-02891 6.57E-02 6.63E-02 6.66E-02 6.67E-02 6.74E-02 6.73E-02 6.70E-02892 6.84E-02 6.87E-02 6.93E-02 6.98E-02 7.04E-02 7.01E-02 6.95E-02895 6.64E-02 6.66E-02 6.71E-02 6.73E-02 6.80E-02 6.78E-02 6.76E-02896 6.89E-02 6.87E-02 6.89E-02 6.91E-02 6.89E-02 6.88E-02 6.89E-02

Biased StatisticsAverage Biased 6.82E-02 6.97E-02 7.04E-02 7.08E-02 7.15E-02 7.10E-02 7.09E-02Std Dev Biased 1.64E-03 1.80E-03 1.74E-03 1.72E-03 2.03E-03 2.07E-03 1.98E-03Ps90%/90% (+KTL) Biased 7.26E-02 7.46E-02 7.52E-02 7.55E-02 7.71E-02 7.67E-02 7.63E-02Ps90%/90% (-KTL) Biased 6.37E-02 6.48E-02 6.56E-02 6.61E-02 6.59E-02 6.53E-02 6.54E-02Un-Biased StatisticsAverage Un-Biased 6.68E-02 6.72E-02 6.76E-02 6.80E-02 6.87E-02 6.84E-02 6.80E-02Std Dev Un-Biased 1.14E-03 1.06E-03 1.08E-03 1.23E-03 1.16E-03 1.13E-03 1.02E-03Ps90%/90% (+KTL) Un-Biased 6.99E-02 7.01E-02 7.06E-02 7.14E-02 7.18E-02 7.15E-02 7.08E-02Ps90%/90% (-KTL) Un-Biased 6.37E-02 6.43E-02 6.47E-02 6.46E-02 6.55E-02 6.53E-02 6.52E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 495: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

495

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

1.40E-01

1.60E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

1mA

@ 5

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.244. Plot of Output Voltage Swing High IL= 1mA @ 5V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 496: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

496

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.244. Raw data for Output Voltage Swing High IL= 1mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 1mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 6.90E-02 7.05E-02 7.09E-02 7.17E-02 7.23E-02 7.18E-02 7.16E-02879 6.92E-02 7.04E-02 7.13E-02 7.19E-02 7.16E-02 7.11E-02 7.09E-02882 6.79E-02 6.96E-02 7.03E-02 7.06E-02 7.11E-02 7.07E-02 7.08E-02883 7.11E-02 7.25E-02 7.34E-02 7.40E-02 7.46E-02 7.40E-02 7.40E-02885 6.97E-02 7.12E-02 7.18E-02 7.17E-02 7.29E-02 7.25E-02 7.25E-02886 6.82E-02 6.85E-02 6.89E-02 6.91E-02 6.98E-02 6.98E-02 6.93E-02887 6.93E-02 6.98E-02 7.03E-02 7.07E-02 7.11E-02 7.11E-02 7.08E-02891 6.93E-02 6.98E-02 7.02E-02 7.08E-02 7.12E-02 7.12E-02 7.08E-02892 6.88E-02 6.91E-02 7.00E-02 7.02E-02 7.10E-02 7.07E-02 7.02E-02895 7.10E-02 7.13E-02 7.20E-02 7.24E-02 7.32E-02 7.27E-02 7.24E-02896 7.18E-02 7.19E-02 7.18E-02 7.19E-02 7.19E-02 7.18E-02 7.18E-02

Biased StatisticsAverage Biased 6.94E-02 7.08E-02 7.15E-02 7.20E-02 7.25E-02 7.20E-02 7.19E-02Std Dev Biased 1.16E-03 1.09E-03 1.16E-03 1.23E-03 1.35E-03 1.30E-03 1.32E-03Ps90%/90% (+KTL) Biased 7.26E-02 7.38E-02 7.47E-02 7.53E-02 7.62E-02 7.56E-02 7.55E-02Ps90%/90% (-KTL) Biased 6.62E-02 6.79E-02 6.84E-02 6.86E-02 6.88E-02 6.85E-02 6.83E-02Un-Biased StatisticsAverage Un-Biased 6.93E-02 6.97E-02 7.03E-02 7.06E-02 7.13E-02 7.11E-02 7.07E-02Std Dev Un-Biased 1.07E-03 1.07E-03 1.14E-03 1.17E-03 1.20E-03 1.04E-03 1.12E-03Ps90%/90% (+KTL) Un-Biased 7.23E-02 7.26E-02 7.34E-02 7.39E-02 7.45E-02 7.39E-02 7.37E-02Ps90%/90% (-KTL) Un-Biased 6.64E-02 6.68E-02 6.72E-02 6.74E-02 6.80E-02 6.82E-02 6.76E-02Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 497: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

497

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

5V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.245. Plot of Output Voltage Swing High IL= 2.5mA @ 5V #1 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 498: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

498

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.245. Raw data for Output Voltage Swing High IL= 2.5mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E-01 1.26E-01 1.27E-01 1.27E-01 1.28E-01 1.27E-01 1.27E-01879 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.27E-01 1.26E-01 1.26E-01882 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01883 1.27E-01 1.28E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01885 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.29E-01886 1.23E-01 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.25E-01 1.25E-01887 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 1.27E-01 1.27E-01891 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01892 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01895 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.29E-01 1.28E-01 1.28E-01896 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01

Biased StatisticsAverage Biased 1.25E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01Std Dev Biased 1.49E-03 1.60E-03 1.66E-03 1.61E-03 1.86E-03 1.83E-03 1.77E-03Ps90%/90% (+KTL) Biased 1.29E-01 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01Ps90%/90% (-KTL) Biased 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01Un-Biased StatisticsAverage Un-Biased 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01Std Dev Un-Biased 1.36E-03 1.38E-03 1.26E-03 1.41E-03 1.26E-03 1.36E-03 1.48E-03Ps90%/90% (+KTL) Un-Biased 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01Ps90%/90% (-KTL) Un-Biased 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.22E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 499: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

499

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

5V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.246. Plot of Output Voltage Swing High IL= 2.5mA @ 5V #2 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 500: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

500

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.246. Raw data for Output Voltage Swing High IL= 2.5mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 1.27E-01 1.27E-01879 1.19E-01 1.21E-01 1.22E-01 1.23E-01 1.23E-01 1.22E-01 1.22E-01882 1.22E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.26E-01883 1.26E-01 1.27E-01 1.28E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01885 1.23E-01 1.25E-01 1.27E-01 1.26E-01 1.28E-01 1.27E-01 1.27E-01886 1.23E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01887 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.21E-01891 1.20E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.22E-01 1.22E-01892 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.25E-01 1.24E-01895 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.21E-01896 1.25E-01 1.25E-01 1.24E-01 1.25E-01 1.24E-01 1.25E-01 1.24E-01

Biased StatisticsAverage Biased 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01Std Dev Biased 2.24E-03 2.44E-03 2.27E-03 2.24E-03 2.56E-03 2.86E-03 2.75E-03Ps90%/90% (+KTL) Biased 1.29E-01 1.31E-01 1.32E-01 1.32E-01 1.34E-01 1.34E-01 1.34E-01Ps90%/90% (-KTL) Biased 1.17E-01 1.18E-01 1.19E-01 1.20E-01 1.20E-01 1.18E-01 1.19E-01Un-Biased StatisticsAverage Un-Biased 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01Std Dev Un-Biased 1.36E-03 1.45E-03 1.16E-03 1.40E-03 1.36E-03 1.28E-03 1.34E-03Ps90%/90% (+KTL) Un-Biased 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01Ps90%/90% (-KTL) Un-Biased 1.17E-01 1.18E-01 1.19E-01 1.19E-01 1.20E-01 1.19E-01 1.19E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 501: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

501

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

5V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.247. Plot of Output Voltage Swing High IL= 2.5mA @ 5V #3 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 502: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

502

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.247. Raw data for Output Voltage Swing High IL= 2.5mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.28E-01 1.27E-01 1.27E-01879 1.19E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.22E-01 1.22E-01882 1.22E-01 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.25E-01883 1.25E-01 1.27E-01 1.28E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01885 1.24E-01 1.26E-01 1.27E-01 1.27E-01 1.28E-01 1.27E-01 1.27E-01886 1.22E-01 1.23E-01 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01887 1.20E-01 1.20E-01 1.21E-01 1.22E-01 1.22E-01 1.22E-01 1.21E-01891 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.22E-01892 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.24E-01895 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.22E-01 1.22E-01 1.22E-01896 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01

Biased StatisticsAverage Biased 1.23E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.26E-01 1.26E-01Std Dev Biased 2.34E-03 2.36E-03 2.34E-03 2.37E-03 2.82E-03 2.71E-03 2.90E-03Ps90%/90% (+KTL) Biased 1.29E-01 1.31E-01 1.32E-01 1.32E-01 1.35E-01 1.34E-01 1.34E-01Ps90%/90% (-KTL) Biased 1.17E-01 1.18E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 1.18E-01Un-Biased StatisticsAverage Un-Biased 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01Std Dev Un-Biased 1.44E-03 1.51E-03 1.36E-03 1.41E-03 1.44E-03 1.24E-03 1.43E-03Ps90%/90% (+KTL) Un-Biased 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.27E-01 1.26E-01 1.27E-01Ps90%/90% (-KTL) Un-Biased 1.17E-01 1.17E-01 1.19E-01 1.19E-01 1.19E-01 1.20E-01 1.19E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 503: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

503

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g H

igh

IL=

2.5m

A @

5V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.248. Plot of Output Voltage Swing High IL= 2.5mA @ 5V #4 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 504: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

504

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.248. Raw data for Output Voltage Swing High IL= 2.5mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing High IL= 2.5mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.25E-01 1.26E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01879 1.24E-01 1.25E-01 1.27E-01 1.27E-01 1.27E-01 1.26E-01 1.26E-01882 1.23E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01883 1.27E-01 1.28E-01 1.30E-01 1.31E-01 1.31E-01 1.30E-01 1.31E-01885 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.30E-01 1.28E-01 1.29E-01886 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.25E-01887 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 1.27E-01 1.27E-01891 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.27E-01 1.26E-01892 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.25E-01895 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.29E-01896 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.29E-01

Biased StatisticsAverage Biased 1.25E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01Std Dev Biased 1.55E-03 1.51E-03 1.75E-03 1.84E-03 2.03E-03 1.86E-03 1.93E-03Ps90%/90% (+KTL) Biased 1.29E-01 1.30E-01 1.32E-01 1.33E-01 1.34E-01 1.33E-01 1.33E-01Ps90%/90% (-KTL) Biased 1.21E-01 1.22E-01 1.22E-01 1.23E-01 1.23E-01 1.22E-01 1.22E-01Un-Biased StatisticsAverage Un-Biased 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 1.27E-01 1.26E-01Std Dev Un-Biased 1.55E-03 1.46E-03 1.51E-03 1.51E-03 1.55E-03 1.41E-03 1.56E-03Ps90%/90% (+KTL) Un-Biased 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01Ps90%/90% (-KTL) Un-Biased 1.20E-01 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.23E-01 1.22E-01Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 505: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

505

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

5V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.249. Plot of Output Voltage Swing Low IL= 0mA @ 5V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 506: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

506

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.249. Raw data for Output Voltage Swing Low IL= 0mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.49E-02 1.51E-02 1.54E-02 1.55E-02 1.56E-02 1.57E-02 1.55E-02879 1.54E-02 1.56E-02 1.58E-02 1.59E-02 1.58E-02 1.57E-02 1.56E-02882 1.46E-02 1.51E-02 1.52E-02 1.53E-02 1.54E-02 1.53E-02 1.52E-02883 1.53E-02 1.55E-02 1.56E-02 1.56E-02 1.59E-02 1.58E-02 1.58E-02885 1.45E-02 1.47E-02 1.48E-02 1.48E-02 1.50E-02 1.50E-02 1.50E-02886 1.49E-02 1.51E-02 1.52E-02 1.54E-02 1.55E-02 1.54E-02 1.52E-02887 1.48E-02 1.50E-02 1.51E-02 1.53E-02 1.55E-02 1.54E-02 1.52E-02891 1.51E-02 1.51E-02 1.52E-02 1.55E-02 1.58E-02 1.55E-02 1.53E-02892 1.51E-02 1.52E-02 1.54E-02 1.54E-02 1.57E-02 1.56E-02 1.54E-02895 1.50E-02 1.52E-02 1.53E-02 1.54E-02 1.56E-02 1.55E-02 1.53E-02896 1.49E-02 1.48E-02 1.48E-02 1.49E-02 1.48E-02 1.48E-02 1.48E-02

Biased StatisticsAverage Biased 1.49E-02 1.52E-02 1.53E-02 1.54E-02 1.56E-02 1.55E-02 1.54E-02Std Dev Biased 4.05E-04 3.57E-04 3.60E-04 4.21E-04 3.60E-04 3.53E-04 3.08E-04Ps90%/90% (+KTL) Biased 1.60E-02 1.62E-02 1.63E-02 1.65E-02 1.65E-02 1.65E-02 1.63E-02Ps90%/90% (-KTL) Biased 1.38E-02 1.42E-02 1.43E-02 1.42E-02 1.46E-02 1.45E-02 1.46E-02Un-Biased StatisticsAverage Un-Biased 1.50E-02 1.51E-02 1.52E-02 1.54E-02 1.56E-02 1.55E-02 1.53E-02Std Dev Un-Biased 1.08E-04 7.46E-05 1.09E-04 4.98E-05 1.28E-04 8.44E-05 1.05E-04Ps90%/90% (+KTL) Un-Biased 1.53E-02 1.53E-02 1.55E-02 1.55E-02 1.59E-02 1.57E-02 1.56E-02Ps90%/90% (-KTL) Un-Biased 1.47E-02 1.49E-02 1.49E-02 1.53E-02 1.52E-02 1.52E-02 1.50E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 507: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

507

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

5V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.250. Plot of Output Voltage Swing Low IL= 0mA @ 5V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 508: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

508

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.250. Raw data for Output Voltage Swing Low IL= 0mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.51E-02 1.53E-02 1.54E-02 1.54E-02 1.55E-02 1.55E-02 1.55E-02879 1.53E-02 1.56E-02 1.58E-02 1.57E-02 1.58E-02 1.59E-02 1.57E-02882 1.48E-02 1.51E-02 1.51E-02 1.52E-02 1.53E-02 1.54E-02 1.55E-02883 1.54E-02 1.58E-02 1.59E-02 1.61E-02 1.64E-02 1.61E-02 1.60E-02885 1.53E-02 1.57E-02 1.59E-02 1.58E-02 1.63E-02 1.62E-02 1.59E-02886 1.52E-02 1.53E-02 1.55E-02 1.57E-02 1.58E-02 1.57E-02 1.56E-02887 1.52E-02 1.53E-02 1.56E-02 1.57E-02 1.60E-02 1.59E-02 1.57E-02891 1.52E-02 1.54E-02 1.56E-02 1.56E-02 1.58E-02 1.59E-02 1.57E-02892 1.56E-02 1.58E-02 1.60E-02 1.61E-02 1.64E-02 1.61E-02 1.60E-02895 1.56E-02 1.57E-02 1.58E-02 1.58E-02 1.61E-02 1.59E-02 1.59E-02896 1.50E-02 1.49E-02 1.48E-02 1.51E-02 1.50E-02 1.51E-02 1.49E-02

Biased StatisticsAverage Biased 1.52E-02 1.55E-02 1.56E-02 1.56E-02 1.59E-02 1.58E-02 1.57E-02Std Dev Biased 2.54E-04 3.03E-04 3.59E-04 3.55E-04 4.93E-04 3.63E-04 2.54E-04Ps90%/90% (+KTL) Biased 1.59E-02 1.63E-02 1.66E-02 1.66E-02 1.72E-02 1.68E-02 1.64E-02Ps90%/90% (-KTL) Biased 1.45E-02 1.47E-02 1.46E-02 1.47E-02 1.45E-02 1.48E-02 1.50E-02Un-Biased StatisticsAverage Un-Biased 1.54E-02 1.55E-02 1.57E-02 1.58E-02 1.60E-02 1.59E-02 1.58E-02Std Dev Un-Biased 1.90E-04 2.20E-04 1.95E-04 2.04E-04 2.29E-04 1.52E-04 1.76E-04Ps90%/90% (+KTL) Un-Biased 1.59E-02 1.61E-02 1.62E-02 1.63E-02 1.66E-02 1.63E-02 1.63E-02Ps90%/90% (-KTL) Un-Biased 1.48E-02 1.49E-02 1.51E-02 1.52E-02 1.54E-02 1.55E-02 1.53E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 509: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

509

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

5V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.251. Plot of Output Voltage Swing Low IL= 0mA @ 5V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 510: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

510

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.251. Raw data for Output Voltage Swing Low IL= 0mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.48E-02 1.50E-02 1.51E-02 1.53E-02 1.56E-02 1.54E-02 1.53E-02879 1.51E-02 1.52E-02 1.54E-02 1.56E-02 1.57E-02 1.55E-02 1.53E-02882 1.47E-02 1.48E-02 1.49E-02 1.50E-02 1.52E-02 1.51E-02 1.52E-02883 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.59E-02 1.58E-02 1.58E-02885 1.52E-02 1.55E-02 1.57E-02 1.58E-02 1.60E-02 1.59E-02 1.58E-02886 1.49E-02 1.52E-02 1.53E-02 1.53E-02 1.56E-02 1.54E-02 1.53E-02887 1.50E-02 1.52E-02 1.54E-02 1.56E-02 1.58E-02 1.57E-02 1.55E-02891 1.50E-02 1.52E-02 1.53E-02 1.55E-02 1.56E-02 1.57E-02 1.52E-02892 1.53E-02 1.53E-02 1.57E-02 1.56E-02 1.59E-02 1.58E-02 1.57E-02895 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.57E-02 1.56E-02 1.55E-02896 1.46E-02 1.45E-02 1.46E-02 1.46E-02 1.46E-02 1.46E-02 1.47E-02

Biased StatisticsAverage Biased 1.50E-02 1.51E-02 1.53E-02 1.54E-02 1.57E-02 1.55E-02 1.55E-02Std Dev Biased 2.41E-04 2.66E-04 3.27E-04 3.29E-04 3.15E-04 3.14E-04 2.88E-04Ps90%/90% (+KTL) Biased 1.57E-02 1.59E-02 1.62E-02 1.63E-02 1.65E-02 1.64E-02 1.63E-02Ps90%/90% (-KTL) Biased 1.43E-02 1.44E-02 1.44E-02 1.45E-02 1.48E-02 1.47E-02 1.47E-02Un-Biased StatisticsAverage Un-Biased 1.51E-02 1.52E-02 1.54E-02 1.55E-02 1.57E-02 1.56E-02 1.54E-02Std Dev Un-Biased 1.72E-04 5.64E-05 1.34E-04 1.25E-04 1.14E-04 1.50E-04 1.74E-04Ps90%/90% (+KTL) Un-Biased 1.55E-02 1.54E-02 1.58E-02 1.58E-02 1.60E-02 1.61E-02 1.59E-02Ps90%/90% (-KTL) Un-Biased 1.46E-02 1.51E-02 1.51E-02 1.51E-02 1.54E-02 1.52E-02 1.50E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 511: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

511

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

7.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 0m

A @

5V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.252. Plot of Output Voltage Swing Low IL= 0mA @ 5V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 512: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

512

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.252. Raw data for Output Voltage Swing Low IL= 0mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 0mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 1.53E-02 1.54E-02 1.56E-02 1.57E-02 1.59E-02 1.59E-02 1.58E-02879 1.58E-02 1.62E-02 1.61E-02 1.63E-02 1.65E-02 1.62E-02 1.62E-02882 1.52E-02 1.54E-02 1.55E-02 1.57E-02 1.59E-02 1.58E-02 1.58E-02883 1.52E-02 1.56E-02 1.58E-02 1.59E-02 1.60E-02 1.60E-02 1.59E-02885 1.50E-02 1.53E-02 1.53E-02 1.52E-02 1.56E-02 1.54E-02 1.54E-02886 1.54E-02 1.54E-02 1.55E-02 1.57E-02 1.59E-02 1.59E-02 1.56E-02887 1.54E-02 1.54E-02 1.55E-02 1.56E-02 1.59E-02 1.59E-02 1.57E-02891 1.53E-02 1.54E-02 1.56E-02 1.58E-02 1.60E-02 1.58E-02 1.57E-02892 1.53E-02 1.53E-02 1.56E-02 1.58E-02 1.61E-02 1.58E-02 1.56E-02895 1.54E-02 1.55E-02 1.57E-02 1.59E-02 1.61E-02 1.59E-02 1.57E-02896 1.52E-02 1.50E-02 1.51E-02 1.51E-02 1.51E-02 1.50E-02 1.52E-02

Biased StatisticsAverage Biased 1.53E-02 1.55E-02 1.57E-02 1.58E-02 1.60E-02 1.59E-02 1.58E-02Std Dev Biased 2.98E-04 3.63E-04 3.23E-04 3.85E-04 3.15E-04 2.94E-04 2.57E-04Ps90%/90% (+KTL) Biased 1.61E-02 1.65E-02 1.66E-02 1.68E-02 1.68E-02 1.67E-02 1.65E-02Ps90%/90% (-KTL) Biased 1.45E-02 1.45E-02 1.48E-02 1.47E-02 1.51E-02 1.51E-02 1.51E-02Un-Biased StatisticsAverage Un-Biased 1.54E-02 1.54E-02 1.55E-02 1.57E-02 1.60E-02 1.59E-02 1.57E-02Std Dev Un-Biased 6.16E-05 5.57E-05 8.56E-05 8.79E-05 8.14E-05 3.65E-05 5.72E-05Ps90%/90% (+KTL) Un-Biased 1.55E-02 1.56E-02 1.58E-02 1.60E-02 1.62E-02 1.60E-02 1.58E-02Ps90%/90% (-KTL) Un-Biased 1.52E-02 1.52E-02 1.53E-02 1.55E-02 1.58E-02 1.58E-02 1.55E-02Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 513: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

513

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

5V

#1 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.253. Plot of Output Voltage Swing Low IL= 1mA @ 5V #1 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 514: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

514

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.253. Raw data for Output Voltage Swing Low IL= 1mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.43E-02 3.46E-02 3.48E-02 3.49E-02 3.53E-02 3.53E-02 3.51E-02879 3.47E-02 3.48E-02 3.50E-02 3.52E-02 3.53E-02 3.50E-02 3.50E-02882 3.39E-02 3.41E-02 3.43E-02 3.44E-02 3.47E-02 3.46E-02 3.45E-02883 3.46E-02 3.51E-02 3.52E-02 3.53E-02 3.56E-02 3.57E-02 3.53E-02885 3.37E-02 3.39E-02 3.41E-02 3.39E-02 3.45E-02 3.45E-02 3.44E-02886 3.40E-02 3.41E-02 3.44E-02 3.45E-02 3.49E-02 3.47E-02 3.46E-02887 3.40E-02 3.41E-02 3.43E-02 3.45E-02 3.49E-02 3.47E-02 3.44E-02891 3.42E-02 3.41E-02 3.44E-02 3.45E-02 3.49E-02 3.45E-02 3.45E-02892 3.41E-02 3.43E-02 3.46E-02 3.47E-02 3.50E-02 3.48E-02 3.46E-02895 3.41E-02 3.44E-02 3.46E-02 3.47E-02 3.51E-02 3.48E-02 3.47E-02896 3.37E-02 3.38E-02 3.37E-02 3.36E-02 3.37E-02 3.36E-02 3.38E-02

Biased StatisticsAverage Biased 3.42E-02 3.45E-02 3.47E-02 3.47E-02 3.51E-02 3.50E-02 3.49E-02Std Dev Biased 4.58E-04 4.95E-04 4.59E-04 6.00E-04 4.49E-04 5.03E-04 3.85E-04Ps90%/90% (+KTL) Biased 3.55E-02 3.58E-02 3.59E-02 3.64E-02 3.63E-02 3.64E-02 3.59E-02Ps90%/90% (-KTL) Biased 3.30E-02 3.31E-02 3.34E-02 3.31E-02 3.39E-02 3.36E-02 3.38E-02Un-Biased StatisticsAverage Un-Biased 3.41E-02 3.42E-02 3.44E-02 3.46E-02 3.49E-02 3.47E-02 3.45E-02Std Dev Un-Biased 8.35E-05 1.36E-04 1.35E-04 1.13E-04 7.00E-05 1.33E-04 1.10E-04Ps90%/90% (+KTL) Un-Biased 3.43E-02 3.46E-02 3.48E-02 3.49E-02 3.51E-02 3.51E-02 3.48E-02Ps90%/90% (-KTL) Un-Biased 3.38E-02 3.38E-02 3.41E-02 3.43E-02 3.47E-02 3.43E-02 3.42E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 515: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

515

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

5V

#2 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.254. Plot of Output Voltage Swing Low IL= 1mA @ 5V #2 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 516: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

516

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.254. Raw data for Output Voltage Swing Low IL= 1mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.41E-02 3.44E-02 3.45E-02 3.47E-02 3.50E-02 3.49E-02 3.48E-02879 3.44E-02 3.47E-02 3.50E-02 3.53E-02 3.53E-02 3.50E-02 3.48E-02882 3.40E-02 3.43E-02 3.45E-02 3.45E-02 3.48E-02 3.47E-02 3.46E-02883 3.49E-02 3.52E-02 3.55E-02 3.57E-02 3.61E-02 3.60E-02 3.57E-02885 3.46E-02 3.50E-02 3.53E-02 3.52E-02 3.59E-02 3.55E-02 3.57E-02886 3.45E-02 3.46E-02 3.47E-02 3.49E-02 3.53E-02 3.50E-02 3.48E-02887 3.44E-02 3.46E-02 3.48E-02 3.50E-02 3.52E-02 3.52E-02 3.50E-02891 3.42E-02 3.42E-02 3.44E-02 3.46E-02 3.48E-02 3.47E-02 3.46E-02892 3.50E-02 3.53E-02 3.53E-02 3.55E-02 3.58E-02 3.57E-02 3.56E-02895 3.44E-02 3.44E-02 3.47E-02 3.46E-02 3.49E-02 3.49E-02 3.46E-02896 3.41E-02 3.41E-02 3.41E-02 3.42E-02 3.40E-02 3.39E-02 3.42E-02

Biased StatisticsAverage Biased 3.44E-02 3.47E-02 3.49E-02 3.51E-02 3.54E-02 3.52E-02 3.51E-02Std Dev Biased 3.60E-04 3.81E-04 4.34E-04 4.76E-04 5.66E-04 5.47E-04 5.34E-04Ps90%/90% (+KTL) Biased 3.54E-02 3.58E-02 3.61E-02 3.64E-02 3.69E-02 3.67E-02 3.66E-02Ps90%/90% (-KTL) Biased 3.34E-02 3.37E-02 3.37E-02 3.38E-02 3.38E-02 3.37E-02 3.36E-02Un-Biased StatisticsAverage Un-Biased 3.45E-02 3.46E-02 3.48E-02 3.49E-02 3.52E-02 3.51E-02 3.49E-02Std Dev Un-Biased 2.94E-04 4.39E-04 3.15E-04 3.48E-04 3.92E-04 3.61E-04 3.91E-04Ps90%/90% (+KTL) Un-Biased 3.53E-02 3.58E-02 3.56E-02 3.59E-02 3.63E-02 3.61E-02 3.60E-02Ps90%/90% (-KTL) Un-Biased 3.37E-02 3.34E-02 3.39E-02 3.40E-02 3.41E-02 3.41E-02 3.38E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 517: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

517

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

5V

#3 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.255. Plot of Output Voltage Swing Low IL= 1mA @ 5V #3 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 518: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

518

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.255. Raw data for Output Voltage Swing Low IL= 1mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.39E-02 3.40E-02 3.42E-02 3.45E-02 3.47E-02 3.47E-02 3.45E-02879 3.38E-02 3.42E-02 3.44E-02 3.47E-02 3.47E-02 3.44E-02 3.44E-02882 3.36E-02 3.38E-02 3.40E-02 3.41E-02 3.43E-02 3.44E-02 3.43E-02883 3.43E-02 3.45E-02 3.48E-02 3.51E-02 3.54E-02 3.52E-02 3.52E-02885 3.46E-02 3.49E-02 3.50E-02 3.50E-02 3.56E-02 3.54E-02 3.52E-02886 3.41E-02 3.42E-02 3.44E-02 3.45E-02 3.49E-02 3.46E-02 3.45E-02887 3.41E-02 3.41E-02 3.44E-02 3.46E-02 3.49E-02 3.49E-02 3.44E-02891 3.38E-02 3.40E-02 3.41E-02 3.44E-02 3.45E-02 3.45E-02 3.44E-02892 3.45E-02 3.47E-02 3.48E-02 3.50E-02 3.53E-02 3.51E-02 3.50E-02895 3.39E-02 3.38E-02 3.43E-02 3.43E-02 3.46E-02 3.45E-02 3.43E-02896 3.38E-02 3.37E-02 3.37E-02 3.38E-02 3.38E-02 3.35E-02 3.36E-02

Biased StatisticsAverage Biased 3.40E-02 3.43E-02 3.45E-02 3.47E-02 3.49E-02 3.48E-02 3.47E-02Std Dev Biased 4.01E-04 4.38E-04 4.22E-04 4.05E-04 5.29E-04 4.52E-04 4.51E-04Ps90%/90% (+KTL) Biased 3.51E-02 3.55E-02 3.56E-02 3.58E-02 3.64E-02 3.60E-02 3.60E-02Ps90%/90% (-KTL) Biased 3.29E-02 3.31E-02 3.33E-02 3.36E-02 3.35E-02 3.36E-02 3.35E-02Un-Biased StatisticsAverage Un-Biased 3.41E-02 3.42E-02 3.44E-02 3.45E-02 3.49E-02 3.47E-02 3.45E-02Std Dev Un-Biased 2.73E-04 3.45E-04 2.42E-04 2.99E-04 3.23E-04 2.95E-04 2.70E-04Ps90%/90% (+KTL) Un-Biased 3.48E-02 3.51E-02 3.51E-02 3.54E-02 3.57E-02 3.55E-02 3.53E-02Ps90%/90% (-KTL) Un-Biased 3.33E-02 3.32E-02 3.38E-02 3.37E-02 3.40E-02 3.39E-02 3.38E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 519: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

519

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

2.00E-02

4.00E-02

6.00E-02

8.00E-02

1.00E-01

1.20E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 1m

A @

5V

#4 (V

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.256. Plot of Output Voltage Swing Low IL= 1mA @ 5V #4 (V) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 520: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

520

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.256. Raw data for Output Voltage Swing Low IL= 1mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 1mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 3.47E-02 3.49E-02 3.50E-02 3.50E-02 3.54E-02 3.54E-02 3.53E-02879 3.51E-02 3.54E-02 3.54E-02 3.58E-02 3.58E-02 3.55E-02 3.54E-02882 3.43E-02 3.46E-02 3.48E-02 3.51E-02 3.53E-02 3.51E-02 3.52E-02883 3.49E-02 3.52E-02 3.53E-02 3.54E-02 3.59E-02 3.57E-02 3.57E-02885 3.40E-02 3.45E-02 3.47E-02 3.45E-02 3.52E-02 3.49E-02 3.49E-02886 3.47E-02 3.47E-02 3.48E-02 3.49E-02 3.53E-02 3.51E-02 3.49E-02887 3.44E-02 3.46E-02 3.47E-02 3.49E-02 3.52E-02 3.51E-02 3.48E-02891 3.46E-02 3.47E-02 3.49E-02 3.52E-02 3.54E-02 3.52E-02 3.50E-02892 3.47E-02 3.46E-02 3.50E-02 3.52E-02 3.55E-02 3.54E-02 3.51E-02895 3.47E-02 3.47E-02 3.51E-02 3.53E-02 3.56E-02 3.55E-02 3.51E-02896 3.43E-02 3.43E-02 3.42E-02 3.42E-02 3.42E-02 3.41E-02 3.43E-02

Biased StatisticsAverage Biased 3.46E-02 3.49E-02 3.50E-02 3.52E-02 3.55E-02 3.53E-02 3.53E-02Std Dev Biased 4.38E-04 3.97E-04 3.12E-04 4.63E-04 2.89E-04 3.39E-04 2.93E-04Ps90%/90% (+KTL) Biased 3.58E-02 3.60E-02 3.59E-02 3.64E-02 3.63E-02 3.62E-02 3.61E-02Ps90%/90% (-KTL) Biased 3.34E-02 3.38E-02 3.42E-02 3.39E-02 3.47E-02 3.44E-02 3.45E-02Un-Biased StatisticsAverage Un-Biased 3.46E-02 3.47E-02 3.49E-02 3.51E-02 3.54E-02 3.53E-02 3.50E-02Std Dev Un-Biased 1.21E-04 4.16E-05 1.53E-04 1.89E-04 1.58E-04 1.70E-04 1.43E-04Ps90%/90% (+KTL) Un-Biased 3.49E-02 3.48E-02 3.53E-02 3.56E-02 3.58E-02 3.57E-02 3.54E-02Ps90%/90% (-KTL) Un-Biased 3.43E-02 3.45E-02 3.45E-02 3.46E-02 3.50E-02 3.48E-02 3.46E-02Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 521: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

521

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 5

V #1

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.257. Plot of Output Voltage Swing Low IL= 2.5mA @ 5V #1 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 522: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

522

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.257. Raw data for Output Voltage Swing Low IL= 2.5mA @ 5V #1 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 5V #1 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.43E-02 7.47E-02 7.45E-02 7.49E-02 7.56E-02 7.52E-02 7.54E-02879 7.38E-02 7.42E-02 7.48E-02 7.50E-02 7.48E-02 7.43E-02 7.44E-02882 7.33E-02 7.37E-02 7.40E-02 7.39E-02 7.42E-02 7.44E-02 7.43E-02883 7.41E-02 7.47E-02 7.50E-02 7.52E-02 7.58E-02 7.54E-02 7.52E-02885 7.26E-02 7.33E-02 7.35E-02 7.36E-02 7.41E-02 7.42E-02 7.36E-02886 7.37E-02 7.39E-02 7.41E-02 7.40E-02 7.47E-02 7.46E-02 7.42E-02887 7.35E-02 7.37E-02 7.40E-02 7.41E-02 7.38E-02 7.41E-02 7.38E-02891 7.33E-02 7.35E-02 7.35E-02 7.40E-02 7.37E-02 7.40E-02 7.35E-02892 7.33E-02 7.41E-02 7.37E-02 7.38E-02 7.46E-02 7.44E-02 7.41E-02895 7.39E-02 7.41E-02 7.43E-02 7.46E-02 7.46E-02 7.48E-02 7.48E-02896 7.32E-02 7.36E-02 7.28E-02 7.30E-02 7.30E-02 7.30E-02 7.31E-02

Biased StatisticsAverage Biased 7.36E-02 7.41E-02 7.43E-02 7.45E-02 7.49E-02 7.47E-02 7.46E-02Std Dev Biased 6.97E-04 6.13E-04 6.01E-04 7.29E-04 7.92E-04 5.75E-04 7.28E-04Ps90%/90% (+KTL) Biased 7.55E-02 7.58E-02 7.60E-02 7.65E-02 7.71E-02 7.63E-02 7.66E-02Ps90%/90% (-KTL) Biased 7.17E-02 7.24E-02 7.27E-02 7.25E-02 7.27E-02 7.31E-02 7.26E-02Un-Biased StatisticsAverage Un-Biased 7.35E-02 7.39E-02 7.39E-02 7.41E-02 7.43E-02 7.44E-02 7.41E-02Std Dev Un-Biased 2.30E-04 2.77E-04 2.91E-04 2.98E-04 4.91E-04 3.06E-04 4.62E-04Ps90%/90% (+KTL) Un-Biased 7.42E-02 7.46E-02 7.47E-02 7.49E-02 7.56E-02 7.52E-02 7.53E-02Ps90%/90% (-KTL) Un-Biased 7.29E-02 7.31E-02 7.31E-02 7.33E-02 7.29E-02 7.35E-02 7.28E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 523: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

523

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 5

V #2

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.258. Plot of Output Voltage Swing Low IL= 2.5mA @ 5V #2 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 524: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

524

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.258. Raw data for Output Voltage Swing Low IL= 2.5mA @ 5V #2 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 5V #2 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.43E-02 7.50E-02 7.50E-02 7.51E-02 7.52E-02 7.52E-02 7.53E-02879 7.33E-02 7.37E-02 7.40E-02 7.46E-02 7.46E-02 7.42E-02 7.43E-02882 7.37E-02 7.36E-02 7.46E-02 7.46E-02 7.50E-02 7.47E-02 7.50E-02883 7.40E-02 7.47E-02 7.52E-02 7.55E-02 7.57E-02 7.55E-02 7.55E-02885 7.42E-02 7.46E-02 7.51E-02 7.50E-02 7.58E-02 7.55E-02 7.53E-02886 7.42E-02 7.45E-02 7.46E-02 7.51E-02 7.53E-02 7.49E-02 7.49E-02887 7.32E-02 7.34E-02 7.40E-02 7.40E-02 7.45E-02 7.44E-02 7.42E-02891 7.34E-02 7.39E-02 7.40E-02 7.42E-02 7.43E-02 7.42E-02 7.41E-02892 7.45E-02 7.47E-02 7.49E-02 7.53E-02 7.55E-02 7.52E-02 7.54E-02895 7.36E-02 7.33E-02 7.38E-02 7.42E-02 7.41E-02 7.42E-02 7.42E-02896 7.40E-02 7.38E-02 7.35E-02 7.36E-02 7.40E-02 7.35E-02 7.36E-02

Biased StatisticsAverage Biased 7.39E-02 7.43E-02 7.48E-02 7.50E-02 7.53E-02 7.50E-02 7.50E-02Std Dev Biased 3.84E-04 6.27E-04 4.74E-04 3.73E-04 5.33E-04 5.57E-04 4.78E-04Ps90%/90% (+KTL) Biased 7.49E-02 7.60E-02 7.61E-02 7.60E-02 7.67E-02 7.65E-02 7.63E-02Ps90%/90% (-KTL) Biased 7.28E-02 7.26E-02 7.35E-02 7.39E-02 7.38E-02 7.35E-02 7.37E-02Un-Biased StatisticsAverage Un-Biased 7.38E-02 7.39E-02 7.43E-02 7.46E-02 7.47E-02 7.46E-02 7.46E-02Std Dev Un-Biased 5.47E-04 6.31E-04 4.46E-04 5.88E-04 6.15E-04 4.63E-04 5.72E-04Ps90%/90% (+KTL) Un-Biased 7.53E-02 7.57E-02 7.55E-02 7.62E-02 7.64E-02 7.59E-02 7.61E-02Ps90%/90% (-KTL) Un-Biased 7.23E-02 7.22E-02 7.30E-02 7.30E-02 7.31E-02 7.33E-02 7.30E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 525: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

525

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 5

V #3

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.259. Plot of Output Voltage Swing Low IL= 2.5mA @ 5V #3 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 526: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

526

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.259. Raw data for Output Voltage Swing Low IL= 2.5mA @ 5V #3 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 5V #3 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.37E-02 7.39E-02 7.43E-02 7.45E-02 7.44E-02 7.48E-02 7.47E-02879 7.26E-02 7.25E-02 7.29E-02 7.33E-02 7.34E-02 7.33E-02 7.31E-02882 7.32E-02 7.33E-02 7.39E-02 7.39E-02 7.43E-02 7.38E-02 7.41E-02883 7.30E-02 7.37E-02 7.43E-02 7.43E-02 7.51E-02 7.46E-02 7.44E-02885 7.37E-02 7.42E-02 7.43E-02 7.46E-02 7.52E-02 7.47E-02 7.46E-02886 7.38E-02 7.36E-02 7.40E-02 7.39E-02 7.48E-02 7.43E-02 7.43E-02887 7.24E-02 7.33E-02 7.33E-02 7.36E-02 7.39E-02 7.37E-02 7.35E-02891 7.31E-02 7.32E-02 7.30E-02 7.35E-02 7.39E-02 7.37E-02 7.37E-02892 7.38E-02 7.39E-02 7.40E-02 7.47E-02 7.50E-02 7.45E-02 7.42E-02895 7.29E-02 7.27E-02 7.31E-02 7.36E-02 7.37E-02 7.35E-02 7.34E-02896 7.31E-02 7.28E-02 7.30E-02 7.30E-02 7.31E-02 7.28E-02 7.31E-02

Biased StatisticsAverage Biased 7.32E-02 7.35E-02 7.39E-02 7.41E-02 7.45E-02 7.42E-02 7.42E-02Std Dev Biased 4.79E-04 6.80E-04 6.13E-04 5.09E-04 7.26E-04 6.44E-04 6.60E-04Ps90%/90% (+KTL) Biased 7.45E-02 7.54E-02 7.56E-02 7.55E-02 7.65E-02 7.60E-02 7.60E-02Ps90%/90% (-KTL) Biased 7.19E-02 7.17E-02 7.23E-02 7.27E-02 7.25E-02 7.25E-02 7.23E-02Un-Biased StatisticsAverage Un-Biased 7.32E-02 7.33E-02 7.35E-02 7.39E-02 7.42E-02 7.39E-02 7.38E-02Std Dev Un-Biased 6.10E-04 4.76E-04 4.74E-04 5.19E-04 6.09E-04 4.25E-04 4.01E-04Ps90%/90% (+KTL) Un-Biased 7.49E-02 7.46E-02 7.48E-02 7.53E-02 7.59E-02 7.51E-02 7.49E-02Ps90%/90% (-KTL) Un-Biased 7.15E-02 7.20E-02 7.22E-02 7.24E-02 7.26E-02 7.28E-02 7.27E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 527: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

527

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Out

put V

olta

ge S

win

g Lo

w IL

= 2.

5mA

@ 5

V #4

(V)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.260. Plot of Output Voltage Swing Low IL= 2.5mA @ 5V #4 (V) versus total dose. The data showno significant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 528: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

528

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.260. Raw data for Output Voltage Swing Low IL= 2.5mA @ 5V #4 (V) versus totaldose, including the statistical analysis, specification and the status of the testing (pass/fail).

Output Voltage Swing Low IL= 2.5mA @ 5V #4 (V) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 7.44E-02 7.50E-02 7.53E-02 7.53E-02 7.56E-02 7.53E-02 7.58E-02879 7.46E-02 7.49E-02 7.54E-02 7.53E-02 7.58E-02 7.53E-02 7.49E-02882 7.39E-02 7.41E-02 7.47E-02 7.51E-02 7.52E-02 7.50E-02 7.50E-02883 7.49E-02 7.50E-02 7.56E-02 7.59E-02 7.62E-02 7.61E-02 7.59E-02885 7.36E-02 7.41E-02 7.48E-02 7.43E-02 7.50E-02 7.51E-02 7.46E-02886 7.47E-02 7.46E-02 7.46E-02 7.48E-02 7.51E-02 7.52E-02 7.47E-02887 7.41E-02 7.43E-02 7.46E-02 7.48E-02 7.54E-02 7.50E-02 7.51E-02891 7.44E-02 7.44E-02 7.47E-02 7.49E-02 7.52E-02 7.50E-02 7.50E-02892 7.41E-02 7.43E-02 7.39E-02 7.49E-02 7.51E-02 7.53E-02 7.48E-02895 7.46E-02 7.50E-02 7.51E-02 7.54E-02 7.60E-02 7.55E-02 7.55E-02896 7.40E-02 7.36E-02 7.39E-02 7.40E-02 7.41E-02 7.37E-02 7.41E-02

Biased StatisticsAverage Biased 7.43E-02 7.46E-02 7.52E-02 7.52E-02 7.56E-02 7.53E-02 7.52E-02Std Dev Biased 5.24E-04 4.56E-04 3.88E-04 5.82E-04 4.74E-04 4.34E-04 5.85E-04Ps90%/90% (+KTL) Biased 7.57E-02 7.59E-02 7.62E-02 7.68E-02 7.69E-02 7.65E-02 7.68E-02Ps90%/90% (-KTL) Biased 7.28E-02 7.34E-02 7.41E-02 7.36E-02 7.43E-02 7.42E-02 7.36E-02Un-Biased StatisticsAverage Un-Biased 7.44E-02 7.45E-02 7.46E-02 7.49E-02 7.53E-02 7.52E-02 7.50E-02Std Dev Un-Biased 2.81E-04 2.80E-04 4.15E-04 2.33E-04 3.80E-04 2.14E-04 3.36E-04Ps90%/90% (+KTL) Un-Biased 7.51E-02 7.53E-02 7.57E-02 7.56E-02 7.64E-02 7.58E-02 7.59E-02Ps90%/90% (-KTL) Un-Biased 7.36E-02 7.37E-02 7.34E-02 7.43E-02 7.43E-02 7.46E-02 7.41E-02Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 529: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

529

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

5V

#1 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.261. Plot of Positive Short-Circuit Current @ 5V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 530: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

530

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.261. Raw data for Positive Short-Circuit Current @ 5V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 5V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.47E-02 -2.42E-02 -2.39E-02 -2.36E-02 -2.32E-02 -2.34E-02 -2.36E-02879 -2.41E-02 -2.35E-02 -2.32E-02 -2.29E-02 -2.29E-02 -2.31E-02 -2.34E-02882 -2.50E-02 -2.45E-02 -2.41E-02 -2.39E-02 -2.34E-02 -2.36E-02 -2.39E-02883 -2.33E-02 -2.27E-02 -2.24E-02 -2.22E-02 -2.17E-02 -2.19E-02 -2.21E-02885 -2.44E-02 -2.40E-02 -2.37E-02 -2.38E-02 -2.31E-02 -2.33E-02 -2.35E-02886 -2.50E-02 -2.48E-02 -2.45E-02 -2.43E-02 -2.40E-02 -2.40E-02 -2.44E-02887 -2.44E-02 -2.41E-02 -2.39E-02 -2.37E-02 -2.33E-02 -2.34E-02 -2.38E-02891 -2.40E-02 -2.38E-02 -2.36E-02 -2.33E-02 -2.29E-02 -2.29E-02 -2.34E-02892 -2.42E-02 -2.38E-02 -2.35E-02 -2.32E-02 -2.27E-02 -2.27E-02 -2.34E-02895 -2.38E-02 -2.35E-02 -2.33E-02 -2.31E-02 -2.26E-02 -2.26E-02 -2.32E-02896 -2.33E-02 -2.33E-02 -2.33E-02 -2.33E-02 -2.33E-02 -2.33E-02 -2.33E-02

Biased StatisticsAverage Biased -2.43E-02 -2.38E-02 -2.35E-02 -2.32E-02 -2.29E-02 -2.30E-02 -2.33E-02Std Dev Biased 6.36E-04 6.90E-04 6.75E-04 7.17E-04 7.02E-04 6.91E-04 6.85E-04Ps90%/90% (+KTL) Biased -2.26E-02 -2.19E-02 -2.16E-02 -2.13E-02 -2.09E-02 -2.12E-02 -2.14E-02Ps90%/90% (-KTL) Biased -2.61E-02 -2.57E-02 -2.53E-02 -2.52E-02 -2.48E-02 -2.49E-02 -2.52E-02Un-Biased StatisticsAverage Un-Biased -2.43E-02 -2.40E-02 -2.38E-02 -2.35E-02 -2.31E-02 -2.31E-02 -2.36E-02Std Dev Un-Biased 4.57E-04 4.79E-04 4.89E-04 5.14E-04 5.64E-04 5.58E-04 4.74E-04Ps90%/90% (+KTL) Un-Biased -2.30E-02 -2.27E-02 -2.24E-02 -2.21E-02 -2.16E-02 -2.16E-02 -2.23E-02Ps90%/90% (-KTL) Un-Biased -2.55E-02 -2.53E-02 -2.51E-02 -2.49E-02 -2.47E-02 -2.46E-02 -2.49E-02Specification MAX -1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 531: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

531

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

5V

#2 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.262. Plot of Positive Short-Circuit Current @ 5V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 532: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

532

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.262. Raw data for Positive Short-Circuit Current @ 5V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 5V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.53E-02 -2.48E-02 -2.45E-02 -2.43E-02 -2.39E-02 -2.41E-02 -2.43E-02879 -2.42E-02 -2.33E-02 -2.30E-02 -2.24E-02 -2.24E-02 -2.27E-02 -2.31E-02882 -2.56E-02 -2.52E-02 -2.49E-02 -2.47E-02 -2.44E-02 -2.45E-02 -2.47E-02883 -2.32E-02 -2.25E-02 -2.21E-02 -2.18E-02 -2.12E-02 -2.14E-02 -2.17E-02885 -2.42E-02 -2.36E-02 -2.32E-02 -2.33E-02 -2.24E-02 -2.26E-02 -2.29E-02886 -2.53E-02 -2.50E-02 -2.48E-02 -2.46E-02 -2.42E-02 -2.42E-02 -2.47E-02887 -2.39E-02 -2.36E-02 -2.33E-02 -2.30E-02 -2.24E-02 -2.24E-02 -2.32E-02891 -2.57E-02 -2.54E-02 -2.52E-02 -2.49E-02 -2.46E-02 -2.45E-02 -2.50E-02892 -2.40E-02 -2.36E-02 -2.33E-02 -2.30E-02 -2.25E-02 -2.25E-02 -2.32E-02895 -2.64E-02 -2.61E-02 -2.58E-02 -2.56E-02 -2.52E-02 -2.52E-02 -2.57E-02896 -2.46E-02 -2.45E-02 -2.45E-02 -2.46E-02 -2.46E-02 -2.45E-02 -2.46E-02

Biased StatisticsAverage Biased -2.45E-02 -2.39E-02 -2.35E-02 -2.33E-02 -2.29E-02 -2.31E-02 -2.33E-02Std Dev Biased 9.75E-04 1.12E-03 1.16E-03 1.22E-03 1.28E-03 1.25E-03 1.18E-03Ps90%/90% (+KTL) Biased -2.18E-02 -2.08E-02 -2.03E-02 -1.99E-02 -1.93E-02 -1.96E-02 -2.01E-02Ps90%/90% (-KTL) Biased -2.72E-02 -2.69E-02 -2.67E-02 -2.66E-02 -2.64E-02 -2.65E-02 -2.66E-02Un-Biased StatisticsAverage Un-Biased -2.51E-02 -2.47E-02 -2.45E-02 -2.42E-02 -2.38E-02 -2.38E-02 -2.43E-02Std Dev Un-Biased 1.08E-03 1.12E-03 1.15E-03 1.18E-03 1.26E-03 1.25E-03 1.13E-03Ps90%/90% (+KTL) Un-Biased -2.21E-02 -2.17E-02 -2.13E-02 -2.10E-02 -2.03E-02 -2.03E-02 -2.12E-02Ps90%/90% (-KTL) Un-Biased -2.81E-02 -2.78E-02 -2.76E-02 -2.75E-02 -2.72E-02 -2.72E-02 -2.74E-02Specification MAX -1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 533: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

533

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

5V

#3 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.263. Plot of Positive Short-Circuit Current @ 5V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 534: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

534

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.263. Raw data for Positive Short-Circuit Current @ 5V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 5V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.53E-02 -2.49E-02 -2.46E-02 -2.44E-02 -2.40E-02 -2.42E-02 -2.44E-02879 -2.44E-02 -2.35E-02 -2.31E-02 -2.26E-02 -2.26E-02 -2.29E-02 -2.33E-02882 -2.58E-02 -2.54E-02 -2.51E-02 -2.49E-02 -2.46E-02 -2.47E-02 -2.49E-02883 -2.33E-02 -2.26E-02 -2.22E-02 -2.19E-02 -2.13E-02 -2.15E-02 -2.18E-02885 -2.39E-02 -2.33E-02 -2.29E-02 -2.30E-02 -2.21E-02 -2.24E-02 -2.26E-02886 -2.54E-02 -2.51E-02 -2.49E-02 -2.47E-02 -2.43E-02 -2.43E-02 -2.47E-02887 -2.40E-02 -2.37E-02 -2.34E-02 -2.31E-02 -2.25E-02 -2.25E-02 -2.33E-02891 -2.61E-02 -2.58E-02 -2.56E-02 -2.53E-02 -2.49E-02 -2.49E-02 -2.54E-02892 -2.38E-02 -2.33E-02 -2.30E-02 -2.28E-02 -2.22E-02 -2.22E-02 -2.29E-02895 -2.60E-02 -2.57E-02 -2.54E-02 -2.52E-02 -2.48E-02 -2.47E-02 -2.53E-02896 -2.49E-02 -2.49E-02 -2.49E-02 -2.49E-02 -2.49E-02 -2.48E-02 -2.49E-02

Biased StatisticsAverage Biased -2.45E-02 -2.39E-02 -2.36E-02 -2.34E-02 -2.29E-02 -2.31E-02 -2.34E-02Std Dev Biased 1.04E-03 1.18E-03 1.23E-03 1.26E-03 1.36E-03 1.32E-03 1.26E-03Ps90%/90% (+KTL) Biased -2.17E-02 -2.07E-02 -2.02E-02 -1.99E-02 -1.92E-02 -1.95E-02 -1.99E-02Ps90%/90% (-KTL) Biased -2.74E-02 -2.72E-02 -2.70E-02 -2.68E-02 -2.67E-02 -2.68E-02 -2.69E-02Un-Biased StatisticsAverage Un-Biased -2.51E-02 -2.47E-02 -2.45E-02 -2.42E-02 -2.37E-02 -2.37E-02 -2.43E-02Std Dev Un-Biased 1.11E-03 1.15E-03 1.18E-03 1.21E-03 1.29E-03 1.28E-03 1.16E-03Ps90%/90% (+KTL) Un-Biased -2.20E-02 -2.16E-02 -2.12E-02 -2.09E-02 -2.02E-02 -2.02E-02 -2.11E-02Ps90%/90% (-KTL) Un-Biased -2.81E-02 -2.79E-02 -2.77E-02 -2.75E-02 -2.73E-02 -2.72E-02 -2.75E-02Specification MAX -1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 535: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

535

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

-3.00E-02

-2.50E-02

-2.00E-02

-1.50E-02

-1.00E-02

-5.00E-03

0.00E+00

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Posi

tive

Shor

t-Circ

uit C

urre

nt @

5V

#4 (A

)

Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased

Ps90%/90% (+KTL) Un-Biased Specification MAX

24-hr 168-hr Anneal Anneal

Figure 5.264. Plot of Positive Short-Circuit Current @ 5V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 536: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

536

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.264. Raw data for Positive Short-Circuit Current @ 5V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Positive Short-Circuit Current @ 5V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 -2.46E-02 -2.41E-02 -2.38E-02 -2.35E-02 -2.31E-02 -2.33E-02 -2.35E-02879 -2.42E-02 -2.36E-02 -2.33E-02 -2.30E-02 -2.30E-02 -2.32E-02 -2.35E-02882 -2.51E-02 -2.47E-02 -2.43E-02 -2.41E-02 -2.36E-02 -2.38E-02 -2.41E-02883 -2.34E-02 -2.28E-02 -2.25E-02 -2.23E-02 -2.17E-02 -2.20E-02 -2.22E-02885 -2.45E-02 -2.40E-02 -2.37E-02 -2.38E-02 -2.32E-02 -2.34E-02 -2.36E-02886 -2.51E-02 -2.49E-02 -2.47E-02 -2.45E-02 -2.41E-02 -2.41E-02 -2.45E-02887 -2.44E-02 -2.42E-02 -2.39E-02 -2.37E-02 -2.34E-02 -2.34E-02 -2.38E-02891 -2.40E-02 -2.38E-02 -2.35E-02 -2.33E-02 -2.29E-02 -2.29E-02 -2.34E-02892 -2.41E-02 -2.36E-02 -2.33E-02 -2.30E-02 -2.24E-02 -2.25E-02 -2.32E-02895 -2.36E-02 -2.33E-02 -2.31E-02 -2.29E-02 -2.24E-02 -2.24E-02 -2.30E-02896 -2.36E-02 -2.36E-02 -2.36E-02 -2.36E-02 -2.36E-02 -2.36E-02 -2.36E-02

Biased StatisticsAverage Biased -2.44E-02 -2.38E-02 -2.35E-02 -2.33E-02 -2.29E-02 -2.31E-02 -2.34E-02Std Dev Biased 6.41E-04 7.01E-04 6.76E-04 7.17E-04 7.07E-04 6.89E-04 6.89E-04Ps90%/90% (+KTL) Biased -2.26E-02 -2.19E-02 -2.17E-02 -2.14E-02 -2.10E-02 -2.12E-02 -2.15E-02Ps90%/90% (-KTL) Biased -2.61E-02 -2.58E-02 -2.54E-02 -2.53E-02 -2.49E-02 -2.50E-02 -2.53E-02Un-Biased StatisticsAverage Un-Biased -2.42E-02 -2.39E-02 -2.37E-02 -2.35E-02 -2.31E-02 -2.31E-02 -2.36E-02Std Dev Un-Biased 5.71E-04 6.00E-04 6.17E-04 6.37E-04 7.06E-04 7.04E-04 6.04E-04Ps90%/90% (+KTL) Un-Biased -2.27E-02 -2.23E-02 -2.20E-02 -2.17E-02 -2.11E-02 -2.11E-02 -2.19E-02Ps90%/90% (-KTL) Un-Biased -2.58E-02 -2.56E-02 -2.54E-02 -2.52E-02 -2.50E-02 -2.50E-02 -2.52E-02Specification MAX -1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 537: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

537

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 5

V #1

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.265. Plot of Negative Short-Circuit Current @ 5V #1 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 538: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

538

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.265. Raw data for Negative Short-Circuit Current @ 5V #1 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 5V #1 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.91E-02 4.91E-02 4.89E-02 4.87E-02 4.84E-02 4.86E-02 4.85E-02879 4.93E-02 4.93E-02 4.91E-02 4.89E-02 4.87E-02 4.91E-02 4.90E-02882 4.97E-02 4.95E-02 4.93E-02 4.91E-02 4.89E-02 4.92E-02 4.91E-02883 4.75E-02 4.72E-02 4.70E-02 4.69E-02 4.67E-02 4.69E-02 4.68E-02885 4.93E-02 4.91E-02 4.88E-02 4.88E-02 4.84E-02 4.87E-02 4.86E-02886 4.94E-02 4.94E-02 4.93E-02 4.92E-02 4.89E-02 4.92E-02 4.92E-02887 4.89E-02 4.88E-02 4.86E-02 4.84E-02 4.83E-02 4.84E-02 4.85E-02891 4.92E-02 4.90E-02 4.88E-02 4.87E-02 4.85E-02 4.88E-02 4.87E-02892 4.83E-02 4.83E-02 4.81E-02 4.80E-02 4.77E-02 4.80E-02 4.79E-02895 4.77E-02 4.77E-02 4.76E-02 4.75E-02 4.72E-02 4.75E-02 4.75E-02896 4.74E-02 4.76E-02 4.75E-02 4.74E-02 4.75E-02 4.76E-02 4.74E-02

Biased StatisticsAverage Biased 4.90E-02 4.88E-02 4.86E-02 4.85E-02 4.82E-02 4.85E-02 4.84E-02Std Dev Biased 8.44E-04 9.04E-04 9.12E-04 9.12E-04 9.05E-04 9.28E-04 9.14E-04Ps90%/90% (+KTL) Biased 5.13E-02 5.13E-02 5.11E-02 5.10E-02 5.07E-02 5.10E-02 5.09E-02Ps90%/90% (-KTL) Biased 4.66E-02 4.63E-02 4.61E-02 4.60E-02 4.57E-02 4.59E-02 4.59E-02Un-Biased StatisticsAverage Un-Biased 4.87E-02 4.86E-02 4.85E-02 4.83E-02 4.81E-02 4.84E-02 4.83E-02Std Dev Un-Biased 6.97E-04 6.49E-04 6.51E-04 6.63E-04 6.56E-04 6.54E-04 6.42E-04Ps90%/90% (+KTL) Un-Biased 5.06E-02 5.04E-02 5.03E-02 5.02E-02 4.99E-02 5.02E-02 5.01E-02Ps90%/90% (-KTL) Un-Biased 4.68E-02 4.69E-02 4.67E-02 4.65E-02 4.63E-02 4.66E-02 4.66E-02Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 539: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

539

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 5

V #2

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.266. Plot of Negative Short-Circuit Current @ 5V #2 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 540: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

540

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.266. Raw data for Negative Short-Circuit Current @ 5V #2 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 5V #2 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.84E-02 4.83E-02 4.82E-02 4.80E-02 4.77E-02 4.79E-02 4.78E-02879 4.89E-02 4.88E-02 4.86E-02 4.83E-02 4.82E-02 4.86E-02 4.84E-02882 4.94E-02 4.92E-02 4.90E-02 4.88E-02 4.87E-02 4.89E-02 4.88E-02883 4.77E-02 4.74E-02 4.72E-02 4.70E-02 4.68E-02 4.70E-02 4.69E-02885 4.77E-02 4.75E-02 4.73E-02 4.73E-02 4.69E-02 4.71E-02 4.71E-02886 4.93E-02 4.93E-02 4.92E-02 4.91E-02 4.88E-02 4.91E-02 4.90E-02887 4.90E-02 4.88E-02 4.86E-02 4.84E-02 4.82E-02 4.84E-02 4.85E-02891 4.98E-02 4.96E-02 4.94E-02 4.93E-02 4.91E-02 4.94E-02 4.93E-02892 4.80E-02 4.80E-02 4.78E-02 4.77E-02 4.75E-02 4.77E-02 4.77E-02895 5.03E-02 5.04E-02 5.03E-02 5.01E-02 4.99E-02 5.02E-02 5.01E-02896 4.87E-02 4.88E-02 4.88E-02 4.87E-02 4.87E-02 4.89E-02 4.87E-02

Biased StatisticsAverage Biased 4.84E-02 4.82E-02 4.80E-02 4.79E-02 4.76E-02 4.79E-02 4.78E-02Std Dev Biased 7.55E-04 7.76E-04 8.03E-04 7.49E-04 8.11E-04 8.54E-04 8.29E-04Ps90%/90% (+KTL) Biased 5.05E-02 5.04E-02 5.02E-02 4.99E-02 4.99E-02 5.02E-02 5.01E-02Ps90%/90% (-KTL) Biased 4.63E-02 4.61E-02 4.58E-02 4.58E-02 4.54E-02 4.56E-02 4.55E-02Un-Biased StatisticsAverage Un-Biased 4.93E-02 4.92E-02 4.90E-02 4.89E-02 4.87E-02 4.90E-02 4.89E-02Std Dev Un-Biased 8.79E-04 8.99E-04 9.12E-04 9.27E-04 9.07E-04 9.58E-04 9.15E-04Ps90%/90% (+KTL) Un-Biased 5.17E-02 5.17E-02 5.15E-02 5.15E-02 5.12E-02 5.16E-02 5.14E-02Ps90%/90% (-KTL) Un-Biased 4.69E-02 4.67E-02 4.65E-02 4.64E-02 4.62E-02 4.63E-02 4.64E-02Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 541: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

541

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 5

V #3

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.267. Plot of Negative Short-Circuit Current @ 5V #3 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 542: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

542

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.267. Raw data for Negative Short-Circuit Current @ 5V #3 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 5V #3 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.88E-02 4.88E-02 4.87E-02 4.84E-02 4.82E-02 4.84E-02 4.83E-02879 4.96E-02 4.95E-02 4.93E-02 4.91E-02 4.88E-02 4.92E-02 4.92E-02882 5.00E-02 4.99E-02 4.97E-02 4.95E-02 4.94E-02 4.96E-02 4.94E-02883 4.84E-02 4.81E-02 4.79E-02 4.77E-02 4.75E-02 4.77E-02 4.77E-02885 4.83E-02 4.81E-02 4.78E-02 4.78E-02 4.75E-02 4.77E-02 4.76E-02886 4.98E-02 4.99E-02 4.97E-02 4.95E-02 4.93E-02 4.96E-02 4.96E-02887 4.97E-02 4.94E-02 4.92E-02 4.91E-02 4.88E-02 4.91E-02 4.92E-02891 5.01E-02 5.00E-02 4.98E-02 4.97E-02 4.95E-02 4.98E-02 4.97E-02892 4.86E-02 4.86E-02 4.84E-02 4.82E-02 4.81E-02 4.83E-02 4.82E-02895 5.10E-02 5.10E-02 5.09E-02 5.08E-02 5.05E-02 5.08E-02 5.07E-02896 4.93E-02 4.95E-02 4.94E-02 4.93E-02 4.93E-02 4.95E-02 4.93E-02

Biased StatisticsAverage Biased 4.90E-02 4.89E-02 4.87E-02 4.85E-02 4.83E-02 4.85E-02 4.84E-02Std Dev Biased 7.55E-04 8.24E-04 8.23E-04 7.79E-04 8.35E-04 8.70E-04 8.26E-04Ps90%/90% (+KTL) Biased 5.11E-02 5.11E-02 5.09E-02 5.06E-02 5.06E-02 5.09E-02 5.07E-02Ps90%/90% (-KTL) Biased 4.70E-02 4.66E-02 4.64E-02 4.64E-02 4.60E-02 4.61E-02 4.62E-02Un-Biased StatisticsAverage Un-Biased 4.98E-02 4.98E-02 4.96E-02 4.94E-02 4.93E-02 4.95E-02 4.95E-02Std Dev Un-Biased 8.75E-04 8.86E-04 8.88E-04 9.30E-04 8.97E-04 9.26E-04 9.18E-04Ps90%/90% (+KTL) Un-Biased 5.22E-02 5.22E-02 5.20E-02 5.20E-02 5.17E-02 5.21E-02 5.20E-02Ps90%/90% (-KTL) Un-Biased 4.74E-02 4.74E-02 4.72E-02 4.69E-02 4.68E-02 4.70E-02 4.70E-02Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 543: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

543

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

0.00E+00

1.00E-02

2.00E-02

3.00E-02

4.00E-02

5.00E-02

6.00E-02

0 10 20 30 40 50 60 70

Total Dose (krad(Si))

Neg

ativ

e Sh

ort-C

ircui

t Cur

rent

@ 5

V #4

(A)

Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased

Ps90%/90% (-KTL) Un-Biased Specification MIN

24-hr 168-hr Anneal Anneal

Figure 5.268. Plot of Negative Short-Circuit Current @ 5V #4 (A) versus total dose. The data show nosignificant change with radiation. The solid diamonds are the average of the measured data points for thesample irradiated under electrical bias while the shaded diamonds are the average of the measured data pointsfor the units irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of thedata points after application of the KTL statistics on the sample irradiated under electrical bias while the graylines (solid and/or dashed) are the average of the data points after application of the KTL statistics on thesamples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiationminimum and/or maximum specification value as defined in the datasheet and/or test plan.

Page 544: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

544

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Table 5.268. Raw data for Negative Short-Circuit Current @ 5V #4 (A) versus total dose,including the statistical analysis, specification and the status of the testing (pass/fail).

Negative Short-Circuit Current @ 5V #4 (A) 24 hr Anneal

168 hr Anneal

Device 0 10 20 30 50 60 70878 4.83E-02 4.83E-02 4.81E-02 4.80E-02 4.77E-02 4.78E-02 4.78E-02879 4.84E-02 4.83E-02 4.82E-02 4.80E-02 4.78E-02 4.82E-02 4.81E-02882 4.88E-02 4.87E-02 4.84E-02 4.83E-02 4.81E-02 4.83E-02 4.82E-02883 4.67E-02 4.64E-02 4.62E-02 4.61E-02 4.59E-02 4.61E-02 4.60E-02885 4.87E-02 4.84E-02 4.82E-02 4.82E-02 4.78E-02 4.81E-02 4.80E-02886 4.87E-02 4.87E-02 4.86E-02 4.84E-02 4.82E-02 4.84E-02 4.84E-02887 4.81E-02 4.80E-02 4.77E-02 4.77E-02 4.75E-02 4.77E-02 4.77E-02891 4.82E-02 4.81E-02 4.79E-02 4.78E-02 4.76E-02 4.78E-02 4.78E-02892 4.76E-02 4.76E-02 4.74E-02 4.72E-02 4.70E-02 4.72E-02 4.72E-02895 4.69E-02 4.70E-02 4.68E-02 4.67E-02 4.65E-02 4.68E-02 4.67E-02896 4.65E-02 4.67E-02 4.67E-02 4.65E-02 4.66E-02 4.68E-02 4.65E-02

Biased StatisticsAverage Biased 4.82E-02 4.80E-02 4.78E-02 4.77E-02 4.75E-02 4.77E-02 4.76E-02Std Dev Biased 8.59E-04 9.09E-04 9.07E-04 9.22E-04 9.10E-04 9.38E-04 9.20E-04Ps90%/90% (+KTL) Biased 5.05E-02 5.05E-02 5.03E-02 5.02E-02 5.00E-02 5.03E-02 5.01E-02Ps90%/90% (-KTL) Biased 4.58E-02 4.55E-02 4.53E-02 4.52E-02 4.50E-02 4.51E-02 4.51E-02Un-Biased StatisticsAverage Un-Biased 4.79E-02 4.79E-02 4.77E-02 4.76E-02 4.74E-02 4.76E-02 4.76E-02Std Dev Un-Biased 6.73E-04 6.28E-04 6.44E-04 6.64E-04 6.51E-04 6.27E-04 6.44E-04Ps90%/90% (+KTL) Un-Biased 4.97E-02 4.96E-02 4.95E-02 4.94E-02 4.91E-02 4.93E-02 4.93E-02Ps90%/90% (-KTL) Un-Biased 4.60E-02 4.61E-02 4.59E-02 4.57E-02 4.56E-02 4.59E-02 4.58E-02Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03Status PASS PASS PASS PASS PASS PASS PASS

Total Dose (krad(Si))

Page 545: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

545

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

6.0. Summary / Conclusions

The total ionizing dose testing described in this final report was performed using the facilities at Radiation Assured Devices’ Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 84-21 irradiator modified to provide a panoramic exposure. The dose rate for this irradiator ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with a pre-rad baseline reading as well as incremental readings at 10, 20, and 30krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. In addition, all units-under-test received a 24hr room temperature and168hr 100°C anneal, using the same bias conditions as the radiation exposure.

The parametric data was obtained as “read and record” and all the raw data plus an attributes summary were presented in this report. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used was 2.742 per MIL HDBK 814 using one- sided tolerance limits of 90/90 and a 5-piece sample size. Note that the following criteria was used to determine the outcome of the testing: following the radiation exposure each parameter had to pass the specification value and the average value for the ten-piece sample must pass the specification value when the KTL limits are applied. If these conditions were not both satisfied following the radiation exposure, then the lot could be logged as a failure.

Using the conditions stated above, the RH1499MW devices passed the RLAT test to 30krad(Si) but failed at 50krad(Si) due to degradation of the output voltage swing and short circuit current for the single-sided 3V supply condition and power supply rejection ratio at the single-sided 2.2V to 12V supply range. Most measured parameters showed no significant degradation with radiation and all parameters passed to 50krad(Si) when tested using the 15V split supply condition.

Page 546: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

546

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Appendix A: Photograph of device-under-test to show part markings

Page 547: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

547

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Appendix B: TID Bias Connections

Biased Samples:

Pin Function Connection / Bias 1 OUT A To Pin 2 via 5kΩ & 40pF, in Parallel 2 -INPUT A To Pin 1 via 5kΩ & 40pF, in Parallel 3 +INPUT A To 8V via 5kΩ Resistor 4 V+ To +15V using 0.1μF Decoupling 5 +INPUT B To 8V via 5kΩ Resistor 6 -INPUT B To Pin 7 via 5kΩ & 40pF, in Parallel 7 OUT B To Pin 6 via 5kΩ & 40pF, in Parallel 8 OUT C To Pin 9 via 5kΩ & 40pF, in Parallel 9 -INPUT C To Pin 8 via 5kΩ & 40pF, in Parallel

10 +INPUT C To 8V via 5kΩ Resistor 11 V- To -15V using 0.1μF Decoupling 12 +INPUT D To 8V via 10kΩ Resistor 13 -INPUT D To Pin 14 via 5kΩ & 40pF, in Parallel 14 OUT D To Pin 13 via 5kΩ & 40pF, in Parallel

Page 548: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

548

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Unbiased Samples:

Pin Function Connection / Bias 1 OUT A GND 2 -INPUT A GND 3 +INPUT A GND 4 V+ GND 5 +INPUT B GND 6 -INPUT B GND 7 OUT B GND 8 OUT C GND 9 -INPUT C GND

10 +INPUT C GND 11 V- GND 12 +INPUT D GND 13 -INPUT D GND 14 OUT D GND

Page 549: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

549

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Figure B.1. Irradiation bias drawing for the units to be irradiated under electrical bias. This figure was extractedfrom LINEAR TECHNOLOGY CORPORATION, RH1499M Datasheet.

Figure B.2. W package drawing (for reference only). This figure was extracted from LINEAR TECHNOLOGYCORPORATION, RH1499M Datasheet.

Page 550: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

550

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Appendix C: Electrical Test Parameters and Conditions All electrical tests for this device are performed on one of Radiation Assured Device’s LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The tests will be conducted using the LTS-2101 Linear Family Board, LTS-0600 Socket Assembly and the RH1499 BGS-061114 DUT board. The measured parameters and test conditions are shown in Tables C.1 (VS=±15V), C.2 (VS=3V), and C.3 (VS=5V). A listing of the measurement precision/resolution for each parameter is shown in Tables C.4 (VS=±15V), C.5 (VS=3V), and C.6 (VS=5V). The precision/resolution values were obtained either from test data or from the DAC resolution of the LTS-2020. To generate the precision/resolution shown in Table C.4 through C.6, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. One such parameter is pre-irradiation Open Loop Gain, where the device exhibits extreme sensitivity to input conditions, resulting in a very large standard deviation. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach.

Page 551: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

551

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

TEST DESCRIPTION TEST CONDITIONS Positive Supply Current V+=15V and V-=-15V Negative Supply Current V+=15V and V-=-15V

Input Offset Voltage (Op Amp 1-4) V+=15V, V-=-15V and VCM=0V Input Offset Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=0V + Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=0V - Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=0V Input Offset Voltage (Op Amp 1-4) V+=15V, V-=-15V and VCM=15V Input Offset Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=15V + Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=15V - Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=15V Input Offset Voltage (Op Amp 1-4) V+=15V, V-=-15V and VCM=-15V Input Offset Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=-15V + Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=-15V - Input Bias Current (Op Amp 1-4) V+=15V, V-=-15V and VCM=-15V

Large Signal Voltage Gain (Op Amp 1-4) RL = 10kΩ, VO = ±14.5V Large Signal Voltage Gain (Op Amp 1-4) RL = 2kΩ, VO = ±10V

CMRR (Op Amp 1-4) VS=±15V, VCM=±15V CMRR Matching 1-4 VS=±15V, VCM=±15V CMRR Matching 2-3 VS=±15V, VCM=±15V PSRR (Op Amp 1-4) VS=±2V to VS=±16V PSRR Matching 1-4 VS=±2V to VS=±16V PSRR Matching 2-3 VS=±2V to VS=±16V

Output Voltage Swing High (Op Amp 1-4) VS=±15V, No Load Output Voltage Swing High (Op Amp 1-4) VS=±15V, ISOURCE=1mA Output Voltage Swing High (Op Amp 1-4) VS=±15V, ISOURCE =10mA Output Voltage Swing Low (Op Amp 1-4) VS=±15V, No Load Output Voltage Swing Low (Op Amp 1-4) VS=±15V, ISINK=1mA Output Voltage Swing Low (Op Amp 1-4) VS=±15V, ISINK=10mA +VS Short-Circuit Current (Op Amp 1-4) VS=±15V -VS Short-Circuit Current (Op Amp 1-4) VS=±15V

Table C.1. Measured parameters and test conditions for VS=±15V.

Page 552: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

552

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

TEST DESCRIPTION TEST CONDITIONS Positive Supply Current V+=3V and V-=0V Negative Supply Current V+=3V and V-=0V

Input Offset Voltage (Op Amp 1-4) V+=3V, V-=0V and VCM=0V Input Offset Current (Op Amp 1-4) V+=3V, V-=0V and VCM=0V + Input Bias Current (Op Amp 1-4) V+=3V, V-=0V and VCM=0V - Input Bias Current (Op Amp 1-4) V+=3V, V-=0V and VCM=0V Input Offset Voltage (Op Amp 1-4) V+=3V, V-=0V and VCM=3V Input Offset Current (Op Amp 1-4) V+=3V, V-=0V and VCM=3V + Input Bias Current (Op Amp 1-4) V+=3V, V-=0V and VCM=3V - Input Bias Current (Op Amp 1-4) V+=3V, V-=0V and VCM=3V

Large Signal Voltage Gain (Op Amp 1-4) RL = 10kΩ, VO=75mV to 2.8V CMRR (Op Amp 1-4) VS=3V, VCM=0-3V CMRR Matching 1-4 VS=3V, VCM=0-3V CMRR Matching 2-3 VS=3V, VCM=0-3V

Output Voltage Swing High (Op Amp 1-4) VS=3V, No Load Output Voltage Swing High (Op Amp 1-4) VS=3V, ISOURCE =1mA Output Voltage Swing High (Op Amp 1-4) VS=3V, ISOURCE =2.5mA Output Voltage Swing Low (Op Amp 1-4) VS=3V, No Load Output Voltage Swing Low (Op Amp 1-4) VS=3V, ISINK=1mA Output Voltage Swing Low (Op Amp 1-4) VS=3V, ISINK=2.5mA +VS Short-Circuit Current (Op Amp 1-4) VS=3V -VS Short-Circuit Current (Op Amp 1-4) VS=3V

Table C.2. Measured parameters and test conditions for VS=3V.

Page 553: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

553

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

TEST DESCRIPTION TEST CONDITIONS Positive Supply Current V+=5V and V-=0V Negative Supply Current V+=5V and V-=0V

Input Offset Voltage (Op Amp 1-4) V+=5V, V-=0V and VCM=0V Input Offset Current (Op Amp 1-4) V+=5V, V-=0V and VCM=0V + Input Bias Current (Op Amp 1-4) V+=5V, V-=0V and VCM=0V - Input Bias Current (Op Amp 1-4) V+=5V, V-=0V and VCM=0V Input Offset Voltage (Op Amp 1-4) V+=5V, V-=0V and VCM=5V Input Offset Current (Op Amp 1-4) V+=5V, V-=0V and VCM=5V + Input Bias Current (Op Amp 1-4) V+=5V, V-=0V and VCM=5V - Input Bias Current (Op Amp 1-4) V+=5V, V-=0V and VCM=5V

Large Signal Voltage Gain (Op Amp 1-4) RL = 10kΩ, VO=75mV to 4.8V CMRR (Op Amp 1-4) VS=5V, VCM=0-5V CMRR Matching 1-4 VS=5V, VCM=0-5V CMRR Matching 2-3 VS=5V, VCM=0-5V PSRR (Op Amp 1-4) VS=2.2V to VS=12V PSRR Matching 1-4 VS=2.2V to VS=12V PSRR Matching 2-3 VS=2.2V to VS=12V

Output Voltage Swing High (Op Amp 1-4) VS=5V, No Load Output Voltage Swing High (Op Amp 1-4) VS=5V, ISOURCE =1mA Output Voltage Swing High (Op Amp 1-4) VS=5V, ISOURCE =2.5mA Output Voltage Swing Low (Op Amp 1-4) VS=5V, No Load Output Voltage Swing Low (Op Amp 1-4) VS=5V, ISINK=1mA Output Voltage Swing Low (Op Amp 1-4) VS=5V, ISINK=2.5mA +VS Short-Circuit Current (Op Amp 1-4) VS=5V -VS Short-Circuit Current (Op Amp 1-4) VS=5V

Table C.3. Measured parameters and test conditions for VS=5V.

Page 554: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

554

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Measured Parameter Pre-IrradiationSpecification

Measurement Resolution/Precision

Positive Supply Current 10mA ± 1.08E-04A Negative Supply Current -10mA ± 1.05E-04A

Input Offset Voltage ±800μV ± 1.91E-05V Input Offset Current ±70nA ± 8.92E-10A + Input Bias Current ±715nA ± 6.20E-09A - Input Bias Current ±715nA ± 5.65E-09A

Large Signal Voltage Gain (10kΩ Load) 1000V/mV ± 7.10E+02V/mV Large Signal Voltage Gain (2kΩ Load) 500V/mV ± 1.10E+02V/mV

Common Mode Rejection Ratio 90dB ± 3.84E+00dB Common Mode Rejection Ratio Matching 84dB ± 1.83E-01dB

Power Supply Rejection Ratio 90dB ± 4.11E-01dB Power Supply Rejection Ratio Matching 83dB ± 2.53E-00dB

Output Voltage Swing High (No Load) 10mV ± 1.82E-04V Output Voltage Swing High (ISOURCE=1mA) 150mV ± 6.24E-04V

Output Voltage Swing High (ISOURCE=10mA) 800mV ± 3.00E-03V Output Voltage Swing Low (No Load) 30mV ± 3.72E-04V

Output Voltage Swing Low (ISINK=1mA) 100mV ± 4.74E-04V Output Voltage Swing Low (ISINK=10mA) 500mV ± 1.85E-03V

+VS Short Circuit Current ±15mA ± 5.70E-04A -VS Short Circuit Current ±15mA ± 8.17E-04A

Table C.4. Measured parameters, pre-irradiation specifications and measurement resolutions for VS=±15V.

Page 555: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

555

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Measured Parameter Pre-IrradiationSpecification

Measurement Resolution/Precision

Positive Supply Current 8.8mA ± 1.39E-05A Negative Supply Current -8.8mA ± 2.13E-05A

Input Offset Voltage ±800μV ± 4.53E-06V Input Offset Current ±65nA ± 6.63E-10A + Input Bias Current ±650nA ± 4.87E-09A - Input Bias Current ±650nA ± 5.59E-09A

Large Signal Voltage Gain (10kΩ Load) 500V/mV ± 2.16E+02V/mV Common Mode Rejection Ratio 72dB ± 3.65E-01dB

Common Mode Rejection Ratio Matching 70dB ± 8.62E-02dB Output Voltage Swing High (No Load) 10mV ± 1.59E-04V

Output Voltage Swing High (ISOURCE=1mA) 150mV ± 1.95E-04V Output Voltage Swing High (ISOURCE=2.5mA) 250mV ± 4.07E-04V

Output Voltage Swing Low (No Load) 30mV ± 2.04E-04V Output Voltage Swing Low (ISINK=1mA) 100mV ± 1.91E-04V

Output Voltage Swing Low (ISINK=2.5mA) 200mV ± 3.99E-04V +VS Short Circuit Current ±12mA ± 1.81E-05A -VS Short Circuit Current ±12mA ± 7.36E-05A

Table C.5. Measured parameters, pre-irradiation specifications and measurement resolutions for VS=3V.

Page 556: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

556

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Measured Parameter Pre-Irradiation

Specification Measurement

Resolution/PrecisionPositive Supply Current 8.8mA ± 3.51E-05A Negative Supply Current -8.8mA ± 3.54E-05A

Input Offset Voltage ±800μV ± 7.82E-06V Input Offset Current ±65nA ± 5.95E-10A + Input Bias Current ±650nA ± 6.87E-09A - Input Bias Current ±650nA ± 7.29E-09A

Large Signal Voltage Gain (10kΩ Load) 600V/mV ± 7.14E+02V/mV Common Mode Rejection Ratio 76dB ± 1.04E-00dB

Common Mode Rejection Ratio Matching 75dB ± 1.62E-01dB Power Supply Rejection Ratio 88dB ± 4.84E-00dB

Power Supply Rejection Ratio Matching 82dB ± 1.76E-00dB Output Voltage Swing High (No Load) 10mV ± 1.76E-04V

Output Voltage Swing High (ISOURCE=1mA) 150mV ± 3.07E-04V Output Voltage Swing High (ISOURCE=2.5mA) 250mV ± 4.42E-04V

Output Voltage Swing Low (No Load) 30mV ± 1.75E-04V Output Voltage Swing Low (ISINK=1mA) 100mV ± 1.84E-04V

Output Voltage Swing Low (ISINK=2.5mA) 200mV ± 4.18E-04V +VS Short Circuit Current ±12.5mA ± 4.44E-05A -VS Short Circuit Current ±12.5mA ±1.40E-04A

Table C.6. Measured parameters, pre-irradiation specifications and measurement resolutions for VS=5V.

Page 557: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

557

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

Appendix D: List of Figures used in Section 5 (RLAT Test Results)

5.1 Positive Supply Current (A) 5.2 Negative Supply Current (A) 5.3 Input Offset Voltage @ +/- 15V, VCM= 0 V #1 (V) 5.4 Input Offset Voltage @ +/- 15V, VCM= 0 V #2 (V) 5.5 Input Offset Voltage @ +/- 15V, VCM= 0 V #3 (V) 5.6 Input Offset Voltage @ +/- 15V, VCM= 0 V #4 (V) 5.7 Input Offset Current @ +/- 15V, VCM= 0 V #1 (A) 5.8 Input Offset Current @ +/- 15V, VCM= 0 V #2 (A) 5.9 Input Offset Current @ +/- 15V, VCM= 0 V #3 (A) 5.10 Input Offset Current @ +/- 15V, VCM= 0 V #4 (A) 5.11 Positive Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) 5.12 Positive Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) 5.13 Positive Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) 5.14 Positive Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) 5.15 Negative Input Bias Current @ +/- 15V, VCM= 0 V #1 (A) 5.16 Negative Input Bias Current @ +/- 15V, VCM= 0 V #2 (A) 5.17 Negative Input Bias Current @ +/- 15V, VCM= 0 V #3 (A) 5.18 Negative Input Bias Current @ +/- 15V, VCM= 0 V #4 (A) 5.19 Input Offset Voltage @ +/- 15V, VCM= 15 V #1 (V) 5.20 Input Offset Voltage @ +/- 15V, VCM= 15 V #2 (V) 5.21 Input Offset Voltage @ +/- 15V, VCM= 15 V #3 (V) 5.22 Input Offset Voltage @ +/- 15V, VCM= 15 V #4 (V) 5.23 Input Offset Current @ +/- 15V, VCM= 15 V #1 (A) 5.24 Input Offset Current @ +/- 15V, VCM= 15 V #2 (A) 5.25 Input Offset Current @ +/- 15V, VCM= 15 V #3 (A) 5.26 Input Offset Current @ +/- 15V, VCM= 15 V #4 (A) 5.27 Positive Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) 5.28 Positive Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) 5.29 Positive Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) 5.30 Positive Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) 5.31 Negative Input Bias Current @ +/- 15V, VCM= 15 V #1 (A) 5.32 Negative Input Bias Current @ +/- 15V, VCM= 15 V #2 (A) 5.33 Negative Input Bias Current @ +/- 15V, VCM= 15 V #3 (A) 5.34 Negative Input Bias Current @ +/- 15V, VCM= 15 V #4 (A) 5.35 Input Offset Voltage @ +/- 15V, VCM= -15 V #1 (V) 5.36 Input Offset Voltage @ +/- 15V, VCM= -15 V #2 (V) 5.37 Input Offset Voltage @ +/- 15V, VCM= -15 V #3 (V) 5.38 Input Offset Voltage @ +/- 15V, VCM= -15 V #4 (V) 5.39 Input Offset Current @ +/- 15V, VCM= -15 V #1 (A)

Page 558: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

558

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.40 Input Offset Current @ +/- 15V, VCM= -15 V #2 (A) 5.41 Input Offset Current @ +/- 15V, VCM= -15 V #3 (A) 5.42 Input Offset Current @ +/- 15V, VCM= -15 V #4 (A) 5.43 Positive Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) 5.44 Positive Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) 5.45 Positive Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) 5.46 Positive Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) 5.47 Negative Input Bias Current @ +/- 15V, VCM= -15 V #1 (A) 5.48 Negative Input Bias Current @ +/- 15V, VCM= -15 V #2 (A) 5.49 Negative Input Bias Current @ +/- 15V, VCM= -15 V #3 (A) 5.50 Negative Input Bias Current @ +/- 15V, VCM= -15 V #4 (A) 5.51 Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #1 (V/mV) 5.52 Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #2 (V/mV) 5.53 Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #3 (V/mV) 5.54 Large Signal Voltage Gain RL= 10k, VO=+/- 14.5 V #4 (V/mV) 5.55 Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #1 (V/mV) 5.56 Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #2 (V/mV) 5.57 Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #3 (V/mV) 5.58 Large Signal Voltage Gain RL= 2k, VO=+/- 10 V #4 (V/mV) 5.59 Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #1 (dB) 5.60 Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #2 (dB) 5.61 Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #3 (dB) 5.62 Common Mode Rejection Ratio @ +/- 15 V, VCM=+/- 15 V #4 (dB) 5.63 Common Mode Rejection Ratio Matching 1-4 @ +/- 15 V, VCM=+/- 15 V (dB) 5.64 Common Mode Rejection Ratio Matching 2-3 @ +/- 15 V, VCM=+/- 15 V (dB) 5.65 Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #1 (dB) 5.66 Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #2 (dB) 5.67 Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #3 (dB) 5.68 Power Supply Rejection Ratio @ +/- 2 V to +/- 16 V #4 (dB) 5.69 Power Supply Rejection Ratio Matching 1-4 @ +/- 2 V to +/- 16 V (dB) 5.70 Power Supply Rejection Ratio Matching 2-3 @ +/- 2 V to +/- 16 V (dB) 5.71 Output Voltage Swing High IL= 0 mA @ +/- 15 V #1 (V) 5.72 Output Voltage Swing High IL= 0 mA @ +/- 15 V #2 (V) 5.73 Output Voltage Swing High IL= 0 mA @ +/- 15 V #3 (V) 5.74 Output Voltage Swing High IL= 0 mA @ +/- 15 V #4 (V) 5.75 Output Voltage Swing High IL= 1 mA @ +/- 15 V #1 (V) 5.76 Output Voltage Swing High IL= 1 mA @ +/- 15 V #2 (V) 5.77 Output Voltage Swing High IL= 1 mA @ +/- 15 V #3 (V) 5.78 Output Voltage Swing High IL= 1 mA @ +/- 15 V #4 (V) 5.79 Output Voltage Swing High IL= 10 mA @ +/- 15 V #1 (V) 5.80 Output Voltage Swing High IL= 10 mA @ +/- 15 V #2 (V)

Page 559: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

559

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.81 Output Voltage Swing High IL= 10 mA @ +/- 15 V #3 (V) 5.82 Output Voltage Swing High IL= 10 mA @ +/- 15 V #4 (V) 5.83 Output Voltage Swing Low IL= 0 mA @ +/- 15 V #1 (V) 5.84 Output Voltage Swing Low IL= 0 mA @ +/- 15 V #2 (V) 5.85 Output Voltage Swing Low IL= 0 mA @ +/- 15 V #3 (V) 5.86 Output Voltage Swing Low IL= 0 mA @ +/- 15 V #4 (V) 5.87 Output Voltage Swing Low IL= 1 mA @ +/- 15 V #1 (V) 5.88 Output Voltage Swing Low IL= 1 mA @ +/- 15 V #2 (V) 5.89 Output Voltage Swing Low IL= 1 mA @ +/- 15 V #3 (V) 5.90 Output Voltage Swing Low IL= 1 mA @ +/- 15 V #4 (V) 5.91 Output Voltage Swing Low IL= 10 mA @ +/- 15 V #1 (V) 5.92 Output Voltage Swing Low IL= 10 mA @ +/- 15 V #2 (V) 5.93 Output Voltage Swing Low IL= 10 mA @ +/- 15 V #3 (V) 5.94 Output Voltage Swing Low IL= 10 mA @ +/- 15 V #4 (V) 5.95 Positive Short-Circuit Current @ +/- 15 V #1 (A) 5.96 Positive Short-Circuit Current @ +/- 15 V #2 (A) 5.97 Positive Short-Circuit Current @ +/- 15 V #3 (A) 5.98 Positive Short-Circuit Current @ +/- 15 V #4 (A) 5.99 Negative Short-Circuit Current @ +/- 15 V #1 (A) 5.100 Negative Short-Circuit Current @ +/- 15 V #2 (A) 5.101 Negative Short-Circuit Current @ +/- 15 V #3 (A) 5.102 Negative Short-Circuit Current @ +/- 15 V #4 (A) 5.103 Positive Supply Current @ 3V (A) 5.104 Negative Supply Current @ 3V (A) 5.105 Input Offset Voltage @ 3V, VCM=0V #1 (V) 5.106 Input Offset Voltage @ 3V, VCM=0V #2 (V) 5.107 Input Offset Voltage @ 3V, VCM=0V #3 (V) 5.108 Input Offset Voltage @ 3V, VCM=0V #4 (V) 5.109 Input Offset Current @ 3V, VCM=0V #1 (A) 5.110 Input Offset Current @ 3V, VCM=0V #2 (A) 5.111 Input Offset Current @ 3V, VCM=0V #3 (A) 5.112 Input Offset Current @ 3V, VCM=0V #4 (A) 5.113 Positive Input Bias Current @ 3V, VCM=0V #1 (A) 5.114 Positive Input Bias Current @ 3V, VCM=0V #2 (A) 5.115 Positive Input Bias Current @ 3V, VCM=0V #3 (A) 5.116 Positive Input Bias Current @ 3V, VCM=0V #4 (A) 5.117 Negative Input Bias Current @ 3V, VCM=0V #1 (A) 5.118 Negative Input Bias Current @ 3V, VCM=0V #2 (A) 5.119 Negative Input Bias Current @ 3V, VCM=0V #3 (A) 5.120 Negative Input Bias Current @ 3V, VCM=0V #4 (A) 5.121 Input Offset Voltage @ 3V, VCM=3V #1 (V)

Page 560: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

560

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.122 Input Offset Voltage @ 3V, VCM=3V #2 (V) 5.123 Input Offset Voltage @ 3V, VCM=3V #3 (V) 5.124 Input Offset Voltage @ 3V, VCM=3V #4 (V) 5.125 Input Offset Current @ 3V, VCM=3V #1 (A) 5.126 Input Offset Current @ 3V, VCM=3V #2 (A) 5.127 Input Offset Current @ 3V, VCM=3V #3 (A) 5.128 Input Offset Current @ 3V, VCM=3V #4 (A) 5.129 Positive Input Bias Current @ 3V, VCM=3V #1 (A) 5.130 Positive Input Bias Current @ 3V, VCM=3V #2 (A) 5.131 Positive Input Bias Current @ 3V, VCM=3V #3 (A) 5.132 Positive Input Bias Current @ 3V, VCM=3V #4 (A) 5.133 Negative Input Bias Current @ 3V, VCM=3V #1 (A) 5.134 Negative Input Bias Current @ 3V, VCM=3V #2 (A) 5.135 Negative Input Bias Current @ 3V, VCM=3V #3 (A) 5.136 Negative Input Bias Current @ 3V, VCM=3V #4 (A) 5.137 Large Signal Voltage Gain @ 3V #1 (V/mV) 5.138 Large Signal Voltage Gain @ 3V #2 (V/mV) 5.139 Large Signal Voltage Gain @ 3V #3 (V/mV) 5.140 Large Signal Voltage Gain @ 3V #4 (V/mV) 5.141 Large Signal Voltage Gain @ 3V #1 (dB) 5.142 Large Signal Voltage Gain @ 3V #2 (dB) 5.143 Large Signal Voltage Gain @ 3V #3 (dB) 5.144 Large Signal Voltage Gain @ 3V #4 (dB) 5.145 Common Mode Rejection Ratio @ 3V #1 (dB) 5.146 Common Mode Rejection Ratio @ 3V #2 (dB) 5.147 Common Mode Rejection Ratio @ 3V #3 (dB) 5.148 Common Mode Rejection Ratio @ 3V #4 (dB) 5.149 Common Mode Rejection Ratio Matching 1-4 @ 3V (dB) 5.150 Common Mode Rejection Ratio Matching 2-3 @ 3V (dB) 5.151 Output Voltage Swing High IL= 0mA @ 3V #1 (V) 5.152 Output Voltage Swing High IL= 0mA @ 3V #2 (V) 5.153 Output Voltage Swing High IL= 0mA @ 3V #3 (V) 5.154 Output Voltage Swing High IL= 0mA @ 3V #4 (V) 5.155 Output Voltage Swing High IL= 1mA @ 3V #1 (V) 5.156 Output Voltage Swing High IL= 1mA @ 3V #2 (V) 5.157 Output Voltage Swing High IL= 1mA @ 3V #3 (V) 5.158 Output Voltage Swing High IL= 1mA @ 3V #4 (V) 5.159 Output Voltage Swing High IL= 2.5mA @ 3V #1 (V) 5.160 Output Voltage Swing High IL= 2.5mA @ 3V #2 (V) 5.161 Output Voltage Swing High IL= 2.5mA @ 3V #3 (V) 5.162 Output Voltage Swing High IL= 2.5mA @ 3V #4 (V)

Page 561: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

561

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.163 Output Voltage Swing Low IL= 0mA @ 3V #1 (V) 5.164 Output Voltage Swing Low IL= 0mA @ 3V #2 (V) 5.165 Output Voltage Swing Low IL= 0mA @ 3V #3 (V) 5.166 Output Voltage Swing Low IL= 0mA @ 3V #4 (V) 5.167 Output Voltage Swing Low IL= 1mA @ 3V #1 (V) 5.168 Output Voltage Swing Low IL= 1mA @ 3V #2 (V) 5.169 Output Voltage Swing Low IL= 1mA @ 3V #3 (V) 5.170 Output Voltage Swing Low IL= 1mA @ 3V #4 (V) 5.171 Output Voltage Swing Low IL= 2.5mA @ 3V #1 (V) 5.172 Output Voltage Swing Low IL= 2.5mA @ 3V #2 (V) 5.173 Output Voltage Swing Low IL= 2.5mA @ 3V #3 (V) 5.174 Output Voltage Swing Low IL= 2.5mA @ 3V #4 (V) 5.175 Positive Short-Circuit Current @ 3V #1 (A) 5.176 Positive Short-Circuit Current @ 3V #2 (A) 5.177 Positive Short-Circuit Current @ 3V #3 (A) 5.178 Positive Short-Circuit Current @ 3V #4 (A) 5.179 Negative Short-Circuit Current @ 3V #1 (A) 5.180 Negative Short-Circuit Current @ 3V #2 (A) 5.181 Negative Short-Circuit Current @ 3V #3 (A) 5.182 Negative Short-Circuit Current @ 3V #4 (A) 5.183 Positive Supply Current @ 5V (A) 5.184 Negative Supply Current @ 5V (A) 5.185 Input Offset Voltage @ 5V, VCM=0V #1 (V) 5.186 Input Offset Voltage @ 5V, VCM=0V #2 (V) 5.187 Input Offset Voltage @ 5V, VCM=0V #3 (V) 5.188 Input Offset Voltage @ 5V, VCM=0V #4 (V) 5.189 Input Offset Current @ 5V, VCM=0V #1 (A) 5.190 Input Offset Current @ 5V, VCM=0V #2 (A) 5.191 Input Offset Current @ 5V, VCM=0V #3 (A) 5.192 Input Offset Current @ 5V, VCM=0V #4 (A) 5.193 Positive Input Bias Current @ 5V, VCM=0V #1 (A) 5.194 Positive Input Bias Current @ 5V, VCM=0V #2 (A) 5.195 Positive Input Bias Current @ 5V, VCM=0V #3 (A) 5.196 Positive Input Bias Current @ 5V, VCM=0V #4 (A) 5.197 Negative Input Bias Current @ 5V, VCM=0V #1 (A) 5.198 Negative Input Bias Current @ 5V, VCM=0V #2 (A) 5.199 Negative Input Bias Current @ 5V, VCM=0V #3 (A) 5.200 Negative Input Bias Current @ 5V, VCM=0V #4 (A) 5.201 Input Offset Voltage @ 5V, VCM=5V #1 (V) 5.202 Input Offset Voltage @ 5V, VCM=5V #2 (V) 5.203 Input Offset Voltage @ 5V, VCM=5V #3 (V)

Page 562: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

562

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.204 Input Offset Voltage @ 5V, VCM=5V #4 (V) 5.205 Input Offset Current @ 5V, VCM=5V #1 (A) 5.206 Input Offset Current @ 5V, VCM=5V #2 (A) 5.207 Input Offset Current @ 5V, VCM=5V #3 (A) 5.208 Input Offset Current @ 5V, VCM=5V #4 (A) 5.209 Positive Input Bias Current @ 5V, VCM=5V #1 (A) 5.210 Positive Input Bias Current @ 5V, VCM=5V #2 (A) 5.211 Positive Input Bias Current @ 5V, VCM=5V #3 (A) 5.212 Positive Input Bias Current @ 5V, VCM=5V #4 (A) 5.213 Negative Input Bias Current @ 5V, VCM=5V #1 (A) 5.214 Negative Input Bias Current @ 5V, VCM=5V #2 (A) 5.215 Negative Input Bias Current @ 5V, VCM=5V #3 (A) 5.216 Negative Input Bias Current @ 5V, VCM=5V #4 (A) 5.217 Large Signal Voltage Gain @ 5V #1 (V/mV) 5.218 Large Signal Voltage Gain @ 5V #2 (V/mV) 5.219 Large Signal Voltage Gain @ 5V #3 (V/mV) 5.220 Large Signal Voltage Gain @ 5V #4 (V/mV) 5.221 Large Signal Voltage Gain @ 5V #1 (dB) 5.222 Large Signal Voltage Gain @ 5V #2 (dB) 5.223 Large Signal Voltage Gain @ 5V #3 (dB) 5.224 Large Signal Voltage Gain @ 5V #4 (dB) 5.225 Common Mode Rejection Ratio @ 5V #1 (dB) 5.226 Common Mode Rejection Ratio @ 5V #2 (dB) 5.227 Common Mode Rejection Ratio @ 5V #3 (dB) 5.228 Common Mode Rejection Ratio @ 5V #4 (dB) 5.229 Common Mode Rejection Ratio Matching 1-4 @ 5V (dB) 5.230 Common Mode Rejection Ratio Matching 2-3 @ 5V (dB) 5.231 Power Supply Rejection Ratio @ 2.2V-12V #1 (dB) 5.232 Power Supply Rejection Ratio @ 2.2V-12V #2 (dB) 5.233 Power Supply Rejection Ratio @ 2.2V-12V #3 (dB) 5.234 Power Supply Rejection Ratio @ 2.2V-12V #4 (dB) 5.235 Power Supply Rejection Ratio Matching 1-4 @ 2.2V-12V (dB) 5.236 Power Supply Rejection Ratio Matching 2-3 @ 2.2V-12V (dB) 5.237 Output Voltage Swing High IL= 0mA @ 5V #1 (V) 5.238 Output Voltage Swing High IL= 0mA @ 5V #2 (V) 5.239 Output Voltage Swing High IL= 0mA @ 5V #3 (V) 5.240 Output Voltage Swing High IL= 0mA @ 5V #4 (V) 5.241 Output Voltage Swing High IL= 1mA @ 5V #1 (V) 5.242 Output Voltage Swing High IL= 1mA @ 5V #2 (V) 5.243 Output Voltage Swing High IL= 1mA @ 5V #3 (V) 5.244 Output Voltage Swing High IL= 1mA @ 5V #4 (V)

Page 563: Radiation Lot Acceptance Test (RLAT) of the RH1499MW Quad ...€¦ · Op Amp for Linear Technology Customer: Linear Technology (PO 49797L) ... determined by the distance from the

RLAT Report 08-134 090626 R1.2

An ISO 9001:2000 Certified Company

563

Radiation Assured Devices5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800

5.245 Output Voltage Swing High IL= 2.5mA @ 5V #1 (V) 5.246 Output Voltage Swing High IL= 2.5mA @ 5V #2 (V) 5.247 Output Voltage Swing High IL= 2.5mA @ 5V #3 (V) 5.248 Output Voltage Swing High IL= 2.5mA @ 5V #4 (V) 5.249 Output Voltage Swing Low IL= 0mA @ 5V #1 (V) 5.250 Output Voltage Swing Low IL= 0mA @ 5V #2 (V) 5.251 Output Voltage Swing Low IL= 0mA @ 5V #3 (V) 5.252 Output Voltage Swing Low IL= 0mA @ 5V #4 (V) 5.253 Output Voltage Swing Low IL= 1mA @ 5V #1 (V) 5.254 Output Voltage Swing Low IL= 1mA @ 5V #2 (V) 5.255 Output Voltage Swing Low IL= 1mA @ 5V #3 (V) 5.256 Output Voltage Swing Low IL= 1mA @ 5V #4 (V) 5.257 Output Voltage Swing Low IL= 2.5mA @ 5V #1 (V) 5.258 Output Voltage Swing Low IL= 2.5mA @ 5V #2 (V) 5.259 Output Voltage Swing Low IL= 2.5mA @ 5V #3 (V) 5.260 Output Voltage Swing Low IL= 2.5mA @ 5V #4 (V) 5.261 Positive Short-Circuit Current @ 5V #1 (A) 5.262 Positive Short-Circuit Current @ 5V #2 (A) 5.263 Positive Short-Circuit Current @ 5V #3 (A) 5.264 Positive Short-Circuit Current @ 5V #4 (A) 5.265 Negative Short-Circuit Current @ 5V #1 (A) 5.266 Negative Short-Circuit Current @ 5V #2 (A) 5.267 Negative Short-Circuit Current @ 5V #3 (A) 5.268 Negative Short-Circuit Current @ 5V #4 (A)