radiation safety in brachytherapy
TRANSCRIPT
Radiation Safety in Radiation Safety in BrachytherapyBrachytherapy
KIRUBHA GKIRUBHA G
20092450022009245002
GroupedGrouped
Patient Safety Patient Safety Public SafetyPublic Safety
Radiation Worker SafetyRadiation Worker Safety
SourcesSources Half -Half -Life Life
Energy of Energy of Radiation Radiation
(MeV)(MeV)
GammaGamma
(Ave) (Ave) Beta Beta
Exp.RatExp.Ratee
const., const., x x
(R.cm(R.cm22..hh-1-1.mCi.mCi--
11) )
Air Air Kerma Kerma Rate Rate const., const., k k ((Gy.mGy.m22..hh-1-1. MBq. MBq--
11))
HVL in HVL in
WaterWater
(cm) (cm)
HVL HVL in in
LeadLead
(mm) (mm)
Ra-226Ra-226 1622 yr1622 yr 0.830.83
( 0.05 - 2.45 ) ( 0.05 - 2.45 ) 0.02 - 0.02 - 3.26 3.26
8.25 8.25 0.195 0.195 10.6 10.6 12.0 12.0
Co-60Co-60 5.26 yr5.26 yr 1.25 1.25 (1.17,1.333) (1.17,1.333)
0.31 0.31 13.07 13.07 0.308 0.308 10.8 10.8 11.0 11.0
Cs-137Cs-137 30 yr30 yr 0.662 0.662 0.51-0.51-1.17 1.17
3.26 3.26 0.077 0.077 8.2 8.2 5.55.5
Ir-192Ir-192 73.84 73.84 daysdays
0.38 0.38
( 0.14 -1.06) ( 0.14 -1.06) 0.67 0.67 4.69 4.69 0.111 0.111 6.3 6.3 2.5 2.5
Au-198Au-198 2.7 days2.7 days 0.412 0.412 0.96 0.96 2.38 2.38 0.056 0.056 7.0 7.0 2.5 2.5
I-125I-125 59.4 days59.4 days 0.028 0.028 1.46 1.46 0.034 0.034 2.0 2.0 0.025 0.025
Pd-103Pd-103 17 days17 days 0.021 0.021 1.48 1.48 0.035 0.035 1.0 1.0 0.008 0.008
RadiationRadiation Worker Safety Worker Safety
TimeTimeDistanceDistanceShieldingShielding
• Quality Control of Sources:Quality Control of Sources:IdentificationIdentification
Leakage & ContaminationLeakage & ContaminationDistribution of ActivityDistribution of Activity
Source Strength VerificationSource Strength Verification
Patient Safety Patient Safety IdentificationIdentification
• Date of receipt Date of receipt
• Type of Type of radionuclideradionuclide • Activity on a given date Activity on a given date • Data on leakage & contamination testData on leakage & contamination test• Recommended working life of the source Recommended working life of the source • Physical and chemical composition of the Physical and chemical composition of the
radioactive source radioactive source • Source encapsulation material and Source encapsulation material and
thickness thickness • Active and physical dimensions, etc Active and physical dimensions, etc
LeakageLeakage and and ContaminationContaminationLimit: < 185 BqLimit: < 185 Bq
DistributionDistribution of Activity of Activity
Source Source StrengthStrength VerificationVerification
• Reference Air Kerma RateReference Air Kerma Rate• Air Kerma StrengthAir Kerma Strength
Quality Control of Quality Control of ApplicatorsApplicators
• Integrity of applicators Integrity of applicators • Precision of source position within Precision of source position within
the applicatorthe applicator• Exactness of the orientation of shield Exactness of the orientation of shield
Quality Control of Quality Control of Treatment UnitTreatment Unit
• Mechanical checks Mechanical checks • Electrical checks Electrical checks • Radiation checks as regards clinical Radiation checks as regards clinical
and radiation safety and radiation safety
Mechanical ChecksMechanical Checks
• Coupling between guide-tube and unitCoupling between guide-tube and unit• Coupling between guide tube and Coupling between guide tube and
applicatorapplicator• Coupling between drive cable and sourceCoupling between drive cable and source• Time taken to drive the source to “ON” Time taken to drive the source to “ON”
positionposition• Time taken to drive the source to “OFF” Time taken to drive the source to “OFF”
positionposition• Source guide free of kinksSource guide free of kinks
Electrical ChecksElectrical Checks
Interlocks:Interlocks:1) Treatment room doors1) Treatment room doors
2) Guide tube & Treatment unit2) Guide tube & Treatment unit
3) Applicator & Guide tube3) Applicator & Guide tube
4) Emergency stop button4) Emergency stop button
Source Safe Display:Source Safe Display:1) Treatment “OFF” 1) Treatment “OFF” indicatorindicator
2) Treatment “ON” indicator2) Treatment “ON” indicator
Control Console Display:Control Console Display:1) Treatment “OFF” indicator1) Treatment “OFF” indicator 2) Treatment “ON” indicator2) Treatment “ON” indicator
3) Source ON/OFF indicator3) Source ON/OFF indicator 4) Door interlock indicator4) Door interlock indicator 5) Retrieval of the source 5) Retrieval of the source
indicatorindicator 6) Retrieval of the 6) Retrieval of the dummy indicatordummy indicator
Control Console Function:Control Console Function:1) Power switch1) Power switch 2) Parameter reset switch2) Parameter reset switch 3) Treatment “ON” switch3) Treatment “ON” switch 4) Treatment “OFF” 4) Treatment “OFF”
indicatorindicator 5) Emergency “OFF” switch5) Emergency “OFF” switch 6) Back-up system provided6) Back-up system provided 7) Treatment & elapsed 7) Treatment & elapsed
time displaytime display 8) Multi-channel indexer 8) Multi-channel indexer
functionfunction
Radiation ChecksRadiation Checks
Leakage & ContaminationLeakage & Contamination
Positioning accuracy & UniformityPositioning accuracy & Uniformity
Source Strength VerificationSource Strength Verification
Quality Assurance of TPS: Quality Assurance of TPS: 1) Single 1) Single
sourcesource
2) Multiple source2) Multiple source
Radiation SafetyRadiation Safety
Well calibrated Survey metersWell calibrated Survey meters
Gamma Zone monitorGamma Zone monitor
CCTVCCTV
Properly working Audio-Visual Properly working Audio-Visual
systemsystem
Radiation LevelRadiation Level
• <100 <100 µGy/hr at 5 cm from the µGy/hr at 5 cm from the surface of the containersurface of the container
• <10 <10 µGy/hr at 1 m from the centre µGy/hr at 1 m from the centre of the containerof the container
RadiationRadiation Level Level
Around the InstallationAround the Installation
• On control console < 100 On control console < 100 µGy/hr µGy/hr • Behind the wall <10 Behind the wall <10 µGy/hrµGy/hr
Radiation SafetyRadiation Safety • Receipt of sources, verification and Receipt of sources, verification and
quality control checks quality control checks • Preparation of applicators for use in Preparation of applicators for use in
the patients the patients • Insertion of the applicators into the Insertion of the applicators into the
patient at the operation theatrepatient at the operation theatre• Removal of applicators and sourcesRemoval of applicators and sources• Sterilization of applicators and sourcesSterilization of applicators and sources• Keeping inventory of sourcesKeeping inventory of sources
Exposure to PublicExposure to Public
• During transportation of patients / During transportation of patients / sources in hospital premises sources in hospital premises
• During treatment (in case of manual During treatment (in case of manual loading techniques) loading techniques)
• Loss or accidental mishandling Loss or accidental mishandling
Reported Radiation Reported Radiation Incidents Incidents
• Loss of sources with hospital wastes Loss of sources with hospital wastes • Inadvertent discharge of patientInadvertent discharge of patient• Cremation of dead body with source Cremation of dead body with source
within within • Spread of contamination by cutting Spread of contamination by cutting
applicator with source stuck in applicator with source stuck in
Necessary to ensure safe work Necessary to ensure safe work practices at all the levels. practices at all the levels.
Safety of SourcesSafety of Sources• Sources should be stored in a secure room Sources should be stored in a secure room
with adequate shieldingwith adequate shielding• Storage should be close to the location in Storage should be close to the location in
which the sources are preparedwhich the sources are prepared• Easily identify the different types of Easily identify the different types of
sources sources • Log book should be maintained Log book should be maintained • Carriers used for transporting the sources: Carriers used for transporting the sources:
adequate shielding and good mobility adequate shielding and good mobility
PatientPatient Care Care • Separate treatment ward with adequate Separate treatment ward with adequate
shielding on all sides and at the entrance shielding on all sides and at the entrance • Distance between two patients should be Distance between two patients should be
such that the dose contribution from one such that the dose contribution from one patient to the other is negligible patient to the other is negligible
• A mobile lead shield may be provided near A mobile lead shield may be provided near each patient to minimize the dose to each patient to minimize the dose to attending staff attending staff
• A sign should be posted on the door A sign should be posted on the door warning of the radiation hazard, in warning of the radiation hazard, in accordance with the regulatory requirement accordance with the regulatory requirement
• Entry by family members should be Entry by family members should be restricted restricted
Cont..Cont..
• Radiation monitor with audio system should Radiation monitor with audio system should always be kept near the entrance door to ensure always be kept near the entrance door to ensure inadvertent movement of sources from the inadvertent movement of sources from the treatment room treatment room
• The implanted patient should be surveyed and The implanted patient should be surveyed and the radiation level at 1m should be notedthe radiation level at 1m should be noted
• After removal, the sources should be counted After removal, the sources should be counted and verified and verified
• For manual afterloading applications: use a For manual afterloading applications: use a mobile shield at the time of insertion, treatment mobile shield at the time of insertion, treatment and removal of sources from the patient. and removal of sources from the patient.
Cont..Cont..
• To transport implanted patients, only To transport implanted patients, only trained hospital staff should be allowed. trained hospital staff should be allowed.
• Crowded hallways as well as areas with Crowded hallways as well as areas with children should be avoided.children should be avoided.
• Patient should never be left unattended in Patient should never be left unattended in unsecured areas.unsecured areas.
• The patient should be discharged only if The patient should be discharged only if the radiation level is within permissible the radiation level is within permissible limitslimits
• The patient should be informed of the The patient should be informed of the nature of radiation hazard and how long nature of radiation hazard and how long they should practice reasonable they should practice reasonable precautions to minimize exposure to precautions to minimize exposure to others. others.
Cont..Cont..
THANK YOUTHANK YOU