radiator heat load€¦ · radiator heat load room name # of radsheight width tubes columns ft of...
TRANSCRIPT
RadiatorHeatLoad
RoomName #ofRads Height Width Tubes Columns FtofCIBB Sections SqFt/Section Total
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
TOTALSQFT:SqFt*150BTUH(@170˚):
PavilionIAQHi-VelocityQuickEnterSheetDATE
JOBNAME**WHOLESALER_____________________CONTRACTOR**
ftftftftsqftsqftsqftsqftsqftsqftftsqftsqftsqft#RoomNameRoomRoomExp.CeilNorthEast/SouthSkylightSE/SWFloorFloorExposedStandardPatioLossGain
LengthWidthWallHeightWindowWestAreaEdgeCeilingDoorsDoorsBTUHBTUH
1****************************
2
3
4
56
7
8
9
1011
12
13
14
1516
17
18
1920Construction&InsulationFactors("R"Value/InchesofInsulation){0"=R3,2"=R7,3.5"=R12,6"=R20,9"=R30,12"=R40}
Circlebelowallfactorsthatapply:Glass(Panes)DesignConditions**ExposedWall0"/2"/3.5"/6"**GlassDoorsgl/dbl**ColdFloorPerimeter1"/2"HeatingTemp.(
OFOutside)**
**Ceiling0"/3.5"/6"/9"/12"**Skylightsgl/dbl**StandardDoorsY/NCoolingTemp.(OFOutside)**
**ColdFloorArea0"/3.5"/6"/9"/12"**Windowssgl/dbl_______AirChange/Hour.5/1.0
AllAreaswith**areneededinordertocompleteloadcalculationPavilionQuickEnter.xls
Degree Day Calculation Heating Degree Days:
Wilmington, DE = 4930 Boston, MA = 5361 Philadelphia, PA = 5180 Concord, NH = 6751 Baltimore, MD = 4680 Montpelier, VT = 7652 New York, NY = 4880 Binghamton, NY = 7340
Sample Calculation 1 Home burns 1000 gallons of heating oil/year.
Location is Philadelphia. Old Boiler is 75% efficient.
HL x 24 x DD F = -------------------- E x P x ΔT
F x E x P x ΔT HL = -------------------
24 x DD
OR
1000 x .75 x 140K x 70 = 7,350,000,000 HL = ---------------------------- ------------------ = 59,121 MBH 24 x 5180 124,320
Sample Calculation 2 Home burns 1600 Therms of natural gas/year.
Location is Boston. Old Boiler is 77% efficient. 1600 x .77 x 99K x 75 = 9,147,600,000 HL = ---------------------------- ------------------ = 71,096 MBH 24 x 5361 128,664
FORMULA
FUEL VALUES: 1 Gallon #2 Heating Oil ≈ 140,000 BTUs
1 Gallon Liquid Propane Gas ≈ 91,000 BTUs 1 Therm of Natural Gas = 100,000 BTUs
Number'of'Baths
Number'of'Bedrooms
Wired'for'Priority
Wired'for'Non5Priority
2 5,100 10,4001'5'1½
3 5,100 10,400
2 5,100 10,400
3 6,100 13,0002'5'2½
4 7,000 14,300
5 10,400 20,500
3 7,000 14,300
4 8,200 17,3003'5'3½
5 10,400 20,500
6 11,000 21,500
Add'to'Heat'Load
Sizing'Additional'Boiler'Load'for'DHW
BTUH%Capacity%by%Pipe%Size
CHART%1:%Steel%Pipe%size Maximum%flow%(gpm) Btuh½" 2 15,000¾" 4 40,0001" 8 80,0001¼" 16 140,0001½" 25 220,0002" 50 450,0002½" 80 850,0003" 140 1,300,0004" 300 3,000,0006" 850 8,500,0008" 1,800 18,000,00010" 3,200 32,000,00012" 5,000 50,000,000
CHART%2:%Copper%tubingTube%size Maximum%flow%(gpm) Btuh
½" 1½ 15,000¾" 4 40,0001" 8 80,0001¼" 14 140,0001½" 22 220,0002" 45 450,0002½" 85 850,0003" 130 1,300,000
CHART%3:%PEX%tubingTube%size Maximum%flow%(gpm) Btuh
⅜" 1.2 12,000
½" 2 20,000
⅝" 4 40,000
¾" 6 60,000
1" 9.5 95,000