Mark E. Schaffer, P.E.
Schaffer Acoustics Inc.Pacific Palisades, CA
Genset Radiator Noise
Return to www.enoisecontrol.com
![Page 2: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/2.jpg)
Sample Municipal Code Limits
75 dBA75 dBAIndustrial
60 dBA65 dBACommercial
45 dBA55 dBAResidential
NighttimeDaytimeLand Use
Codes usually require compliance during testing,but not during emergency operation
ASHRAE TC 2.6
![Page 3: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/3.jpg)
Skid-Mounted Radiator
ASHRAE TC 2.6
![Page 4: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/4.jpg)
1500 KW GensetMechanical Noise
60
70
80
90
100
110
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency in Hertz
L P @
15
met
ers
in d
B
Without Radiator, 89 dBA
With Radiator, 92 dBA
ASHRAE TC 2.6
![Page 5: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/5.jpg)
Acoustical Louver
Length4” – 12 “
Insertion Loss3 – 10 dBA
Pressure Drop∼0.25” w.g.@ 500 FPM
ASHRAE TC 2.6
![Page 6: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/6.jpg)
Lined Duct Transition
Length30” – 120“
Insertion Loss1 to 5 dBA
Pressure Drop0.0” w.g.
ASHRAE TC 2.6
![Page 7: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/7.jpg)
Sound Traps
Length30” – 120“
Insertion Loss10 to 40 dBA
Pressure Drop0.05” to 0.30” w.g.
@ 500 FPM
ASHRAE TC 2.6
![Page 8: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/8.jpg)
Typical Low Noise1.5 MW Genset Installation
118,000 CFM
GeneratorRad
10’ long, 236 ft2 face area
Intake AirSoundTraps
Disch.Air
SoundTraps
ASHRAE TC 2.6
![Page 9: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/9.jpg)
Low Noise Genset Installationwith Remote Radiator
40,000 CFM
Generator
10’ long,80 ft2 face area
IntakeAir
SoundTraps
Disch.Air
SoundTraps
Exh.Fan
ASHRAE TC 2.6
![Page 10: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/10.jpg)
Vertical CoreRemoteRadiator
Note narrowfan blades
ASHRAE TC 2.6
![Page 11: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/11.jpg)
Horizontal CoreRemote Radiator
ASHRAE TC 2.6
![Page 12: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/12.jpg)
Remote Radiator Installation
ASHRAE TC 2.6
![Page 13: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/13.jpg)
RemoteRadiator
Air InletView
Note widefan blades
ASHRAE TC 2.6
![Page 14: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/14.jpg)
Radiator Noise Levels
30
40
50
60
70
80
90
100
110
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency in Hertz
L P @
15
met
ers
in d
B 84” Skid-mounted
64” Remote
81” Remote93” Remote
ASHRAE TC 2.6
![Page 15: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/15.jpg)
Fan Noise Level vs RPM
-20
-15
-10
-5
0
100 95 90 85 80 75 70 65 60 55 50
% of Full RPM
Rel
ativ
e Le
vel i
n d
B
ASHRAE TC 2.6
![Page 16: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/16.jpg)
Differential Costs ofRemote Radiator for 1500 KW
($25,000)($25,000)Radiator
$20,000$5000Room Ventilation
$62,000+$99,400Total
$10,000+---Radiator Piping
$32,000$94,400Sound traps
RemoteRadiator
Skid-MountedRadiator
ASHRAE TC 2.6
![Page 17: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/17.jpg)
Remote Radiator Benefits
• Smaller ventilation opening(1/2 to 2/3 smaller)
• Fewer or shorter sound traps(1/2 to 2/3 reduction)
• More space in generator room
• Option to select quiet radiator
• Option to locate radiator for lowest noiseexposure to noise-sensitive areas
ASHRAE TC 2.6
![Page 18: Radiator Noise Presentation - eNoiseControl · Radiator Noise Control Summary • Use acoustical louvers or sound traps for a skid- mounted radiator, if space is available. • Consider](https://reader033.vdocument.in/reader033/viewer/2022041921/5e6c2cd121c83a47f6758d46/html5/thumbnails/18.jpg)
Radiator Noise Control Summary
• Use acoustical louvers or sound traps for a skid-mounted radiator, if space is available.
• Consider remote radiator if space precludessound traps for skid-mounted radiator.
• Consider several remote radiator fan selections,weighing cost, location and size.
• Consider VFD fan motor for lower speed &lower noise during cooler nighttime ambient airconditions.
Return to www.enoisecontrol.com
ASHRAE TC 2.6