Page 1: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was
Lauzon LSC
Text Box
EXAMPLE 1: GENERATOR MAINTENANCE RECORD Almost any mfgr test report should be satisfactory if it is detailed to show what was accomplished and contain the basic report info
Page 2: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was
Lauzon LSC
Text Box
EXAMPLE 2: GENERATOR MAINTENANCE RECORD Almost any mfgr test report should be satisfactory if it is detailed to show what was accomplished and contain the basic report info
Page 3: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was
Page 4: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was
Page 5: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was
Page 6: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was

ANNUAL GENERATOR MAINTENANCE Facility:Gen Mfgr: YEARGen S/N: Date of Maintenance:

Who Performed: VISUAL CHECK REPL TEST

Tank Vents & Overflow x xPiping x

Gas in Main Tank (if used) x Gal

Oil Change x QtsOil Filter x Type

Anti-Freeze x GalRod Heat Exchanger cleanClean Exterior of Rad x clean

Inspect duct; Clean Louvers x x cleanLouver motors & Controls x clean x

Excess Backpressure xExh sys Hangers/Supports x

Tighten wiring connections xATS Main Contracts x clean

Calib Volt-Sense Devices x x

Generator Oil x x QtsIgnition System x x x x

Injector Pump & Injectors x

Commutator & Slip Rings x cleanRotor & Stator x clean

Bearings x xBearing Grease x x

Exciter x x xVoltage Regulator x x x

Winding Resistance x

Based on NFPA 110 (1999 ed) Appendix A

ENGINE

GENERATOR

EXHAUST SYSTEM

ELECTRICAL SYSTEM

Notation of any unsatisfactory condition and the corrective action taken, including parts replaced. Tests must be documented of any repair for the appropriate time as recommended by the manufacturer.

A 1

ENTER RESULTS OF INSPECTIONSFUEL SYSTEM

LUBRICATION SYSTEM

COOLING SYSTEM

Lauzon LSC
Text Box
EXAMPLE 3: GENERATOR MAINTENANCE RECORD Almost any mfgr test report should be satisfactory if it is detailed to show what was accomplished and contain the basic report info
Page 7: rAlmost any mfgr test report should be satisfactory if it ... 1:\rGENERATOR MAINTENANCE RECORD\rAlmost any mfgr test report should be satisfactory if it is detailed to show what was

QUARTERLY GENERATOR MAINTENANCE Facility:YEAR Qrt 1 Qrt 2 Qrt 3 Qrt 4

Date of Maintenance:Who Performed:

VISUAL CHECK CLEAN TEST FUEL Strainer, Filter, Dirt Leg xLUBE Crankcase Breather x xEXHAUST Insulation & Fire Hazards xBATTERY Terminals Clean & Tight x xELECTRICAL Wire Chafing x x

SEMI-ANNUAL GENERATOR MAINTENANCE

Date of Maintenance:Who Performed:

VISUAL CHECK CLEAN TESTCOOLING Antifreeze Level x 0F Protection 0F Protection

EXHAUST Flex Exhaust Section xELECTRICAL Safeties & Alarms x xELECTRICAL Boxes, panels xGENERATOR Air Cleaner Svc x xGENERATOR Choke & Carb Adjust xGENERATOR Brush length & operation x x x

Based on NFPA 110 (1999 ed) Appendix A

Notation of any unsatisfactory condition and the corrective action taken, including parts replaced. Tests must be documented of any repair for the appropriate time as recommended by the manufacturer.

ENTER RESULTS OF INSPECTIONS

SA 1 SA 2

Lauzon LSC
Text Box
EXAMPLE 4: GENERATOR MAINTENANCE RECORD Almost any mfgr test report should be satisfactory if it is detailed to show what was accomplished and contain the basic report info