ravivariac2

1
Installation and Safety Instructions 1. Installation, commissioning and maintenance should only be carried out by suitably qualified personal. 2. Read all of the Instructions carefully before you use the Transformer. 3. The input must always be applied across the appropriate Terminals. Never connect the Variac Auto Transformer in series with the load. 4. The Variac Auto Transformer should be properly earthed using the earth stud. 5. Variable Transformer Operate at mains Voltage. DO NOT EXCEED THE MAXIMUM VOLTAGE AND CURRENT RATING 6. This Transformer is not designed to provide mains isolation. 7. Please note that when connected to the electrical supply the terminal brushes and track surface are at mains Voltage which is potentially lethal. 8. The Carbon brush should be inspected for damage or wear, faulty over worn brushes will result in damaging the windings. RAVISTAT R RAVI ELECTRICALS PVT. LTD. MFG EXPORTER OF VARIABLE AUTO TRANSFORMER INPUT 240 V. A&C or D INPUT 240 V. A&C or D OUTPUT 0-240V.or 0-270V. A & E 1A MAX OUTPUT 0-240V.or 0-270V. A & E 1A MAX E C A D RAVISTAT RAVISTAT 1Amp 1Amp H A B B A C FIXED CONTACT NYLON BUSH CONNECTION ARRANGEMENT Input - 240V 1ph, 50Hz Output - 0-270V 1ph, 50Hz E D A C L N L N I SINGLE PHASE VARIAC SR. NO.: SR. NO.: RAVISTAT RAVISTAT C E A B D H Note:Not to scale. Maximum operating temperature =45° C, Ø=HOLE, 2-2Amps Max capacity. 1Amp Variac BRUSH ARM Model: 1F-1 INPUT: 240V. 50Hz at A-D OUTPUT: 0-270V at A-E INPUT: 240V. 50Hz at A-D OUTPUT: 0-270V at A-E R Variable Transformer Single Phase, Open/ Flush/ Panel Mounting RAVISTAT Variable Auto Transformer R 1F-1 2F-1 3F-1 4F-1 6F-1 8F-1 10F-1 15F-1 20F-1 28F-1 85 110 110 175 175 175 175 220 220 295 105 140 140 195 195 195 195 250 250 325 - 92 92 146 146 146 146 176 176 238 270 540 810 1080 1620 2160 2700 4050 5400 7560 4 7.5 7.5 10 10 10 10 10 10 10 1.600 2.900 3.300 6.200 6.600 7.800 8.500 12.500 15.000 22.500 1Amp 2Amp 3Amp 4Amp 6Amp 8Amp 10Amp 15Amp 20Amp 28Amp TYPE AMP A B C H MAX V.A. Approx Wt. In KG Ø Dimensions in mm (Approx). RAVISTAT Variable Auto Transformer Model: F-1 Single phase, Open/Flush Type, Panel mounting. Input: 240V 50/60Hz Output: 0-270V 100 125 135 150 165 175 185 180 190 230 8Amps Model: 8F-1 3Amps Model: 3F-1 15Amps Model: 15F-1 Maximum Current 1A 2A 3A 4A 6A 8A 10A 15A 20A 28A Continuous Current 1A 1.8A 2.8A 3.8A 5A 6.5A 9A 12A 17A 25A

Upload: sur-e-jahan

Post on 31-Oct-2014

13 views

Category:

Documents


0 download

TRANSCRIPT

RAVISTAT1Amp VariacA

R

Variable Auto TransformerR

Variable Transformer Single Phase, Open/ Flush/ Panel Mounting

RAVI ELECTRICALS PVT. LTD.MFG EXPORTER OF VARIABLE AUTO TRANSFORMER

E COUTPUT 0-240V.or 0-270V. A & E 1A MAX

C

E

A

AINPUT 240 V. A&C or D

RAVISTATH

1Amp D

H

B

D

B

RAVISTATINDIA MADE IN

TM

SR. NO.:

INPUT: 240V. 50Hz at A-D OUTPUT: 0-270V at A-E

Installation and Safety Instructions1. Installation, commissioning and maintenance should only be carried out by suitably qualified personal. 2. Read all of the Instructions carefully before you use the Transformer. 3. The input must always be applied across the appropriate Terminals. Never connect the Variac Auto Transformer in series with the load. 4. The Variac Auto Transformer should be properly earthed using the earth stud. 5. Variable Transformer Operate at mains Voltage. DO NOT EXCEED THE MAXIMUM VOLTAGE AND CURRENT RATING 6. This Transformer is not designed to provide mains isolation.

RAVISTAT

R

Model: 1F-1

A

3Amps

NYLON BUSH

C

B

BRUSH ARM

8AmpsFIXED CONTACT

Model: 3F-1

15Amps

Model: 8F-1

Dimensions in mm (Approx). RAVISTAT Variable Auto Transformer Model: F-1 Single phase, Open/Flush Type, Panel mounting. Input: 240V 50/60Hz Output: 0-270V

Model: 15F-1

TYPE

AMP

A

B

C

H

MAX V.A.

4 7.5 7.5 10 10 10 10 10 10 10

Approx Wt. In KG

SINGLE PHASE VARIACL Input - 240V 1ph, 50Hz N A N C D E LI

Output - 0-270V 1ph, 50Hz

1F-1 2F-1 3F-1 4F-1 6F-1 8F-1 10F-1 15F-1 20F-1 28F-1

1Amp 2Amp 3Amp 4Amp 6Amp 8Amp 10Amp 15Amp 20Amp 28Amp

85 110 110 175 175 175 175 220 220 295

105 140 140 195 195 195 195 250 250 325

92 92 146 146 146 146 176 176 238

100 125 135 150 165 175 185 180 190 230

270 540 810 1080 1620 2160 2700 4050 5400 7560

1.600 2.900 3.300 6.200 6.600 7.800 8.500 12.500 15.000 22.500

7. Please note that when connected to the electrical supply the terminal brushes and track surface are at mains Voltage which is potentially lethal. 8. The Carbon brush should be inspected for damage or wear, faulty over worn brushes will result in damaging the windings.

CONNECTION ARRANGEMENT

Note:Not to scale. Maximum operating temperature =45 C, =HOLE, 2-2Amps Max capacity.Maximum Current Continuous Current 1A 2A 3A 4A 6A 8A 10A 1A 1.8A 2.8A 3.8A 5A 6.5A 9A 15A 12A 20A 17A 28A 25A