rcd fused spur - tradesparky.com

1
RCD FUSED SPUR Product Finish White Metal Product Dimensions 86 x 86 x 27.2mm 86 x 86 x 26.5mm Product weight 195g 392g Barcode 5012739626289 5012739626272 Voltage 230V AC 50Hz 230V AC 50Hz Max Operating Current 13A (3A inductive) 13A (3A inductive) Rated Trip Current 30mA 30mA Typical Trip Speed Less than 20mS (typical) Less than 20mS (typical) RCD Contact break Double Pole Double Pole Latching Mechanical, no need to reset after a power loss (passive) Mechanical, no need to reset after a power loss (passive) Responsive to Pulsating DC earth faults Pulsating DC earth faults Main housing material Polycarbonate Steel Guarantee 1 Year 1 Year Conforms to BS1363-4:1995 Amd 1,2,3 & BS 7288:1990 Amd 1 BS1363-4:1995 Amd 1,2,3 & BS 7288:1990 Amd 1 EMC Emissions EN 55014-1:2006 & EN 55014-1:2000 inc A1:2001 & A2:2002 EN 55014-1:2006 & EN 55014-1:2000 inc A1:2001 & A2:2002 EMC Immunity EN 61543:1995 inc A11:2003, A12:2005 & A2:2006 EN 61543:1995 inc A11:2003, A12:2005 & A2:2006 H92WPA-C H92MPA-C Mechanically latched (does not need resetting after a power loss) High intensity LED power on indicator, clear visual indicator of power on Mechanical flag trip indicator Integral cord outlet and cable clamp Fuse holder can be locked out for safety Twin earth terminals TECHNICAL DATA SHEET TECHNICAL DATA SHEET Tel +44 (0) 1279 772 772 Fax +44 (0) 1279 422 007 www.greenbrook.co.uk Suitable for use with all electrical appliances, in public washrooms and areas where water is present, plus fixed electric appliances such as domestic machines in the home, cold drink dispensers and hotel hairdryers. 60.3 86.0 86.0 26.5 38.0 86.0 86.0 27.2 13.5 60.3 H92WPA-C H92MPA-C

Upload: others

Post on 16-Jan-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RCD FUSED SPUR - tradesparky.com

RCD FUSED SPUR

Product Finish White Metal

Product Dimensions 86 x 86 x 27.2mm 86 x 86 x 26.5mm

Product weight 195g 392g

Barcode 5012739626289 5012739626272

Voltage 230V AC 50Hz 230V AC 50Hz

Max OperatingCurrent

13A (3A inductive) 13A (3A inductive)

Rated Trip Current 30mA 30mA

Typical Trip Speed Less than 20mS (typical) Less than 20mS (typical)

RCD Contact break Double Pole Double Pole

LatchingMechanical, no need toreset after a power loss

(passive)

Mechanical, no need toreset after a power loss

(passive)

Responsive to Pulsating DCearth faults

Pulsating DCearth faults

Main housingmaterial

Polycarbonate Steel

Guarantee 1 Year 1 Year

Conforms to BS1363-4:1995 Amd 1,2,3 &BS 7288:1990 Amd 1

BS1363-4:1995 Amd 1,2,3 &BS 7288:1990 Amd 1

EMC EmissionsEN 55014-1:2006 & EN

55014-1:2000 inc A1:2001& A2:2002

EN 55014-1:2006 & EN55014-1:2000 inc A1:2001

& A2:2002

EMC Immunity EN 61543:1995 inc A11:2003,A12:2005 & A2:2006

EN 61543:1995 inc A11:2003,A12:2005 & A2:2006

H92WPA

-C

H92MPA

-C

• Mechanically latched (does not need resetting after a power loss)

• High intensity LED power on indicator, clear visual indicator of power on

• Mechanical flag trip indicator

• Integral cord outlet and cable clamp

• Fuse holder can be locked out for safety

• Twin earth terminals

TEC

HN

ICA

L D

ATA

SH

EET

TEC

HN

ICA

L D

ATA

SH

EET

Tel +44 (0) 1279 772 772Fax +44 (0) 1279 422 007

www.greenbrook.co.uk

Suitable for use with all electrical appliances, in public washrooms and areas where water ispresent, plus fixed electric appliances such as domestic machines in the home, cold drinkdispensers and hotel hairdryers.

60.3

86.0

86.0

26.5

38.0

86.0

86.0

27.2

13.560.3

H92WPA-C

H92MPA-C