Index
Features 1Ordering Code / Standard Program 2Technical Data 3...6Ordering Code - Size 5 7Unit Dimensions, Size 5 7Unit Dimensions, Sizes 10, 12, 16 8Unit Dimensions, Sizes 23, 28, 32 9Unit Dimensions, Size 45 10Unit Dimensions, Sizes 56, 63 11Unit Dimensions, Sizes 80, 90 12Unit Dimensions, Sizes 107, 125 13Unit Dimensions, Sizes 160, 180 14Unit Dimensions, Size 200 15Unit Dimensions, Size 250 15Unit Dimensions, Size 355 16Unit Dimensions, Size 500 16Unit Dimensions, Size 710 17Unit Dimensions, Size 1000 17Preferred Types 18Installation and Commissioning Guidelines 19
RE 91 401/09.00
replaces: 01.97
Fixed Displacement Pump A2FOfor open circuits
Sizes 5...1000Series 6Nominal pressure up to 400 barPeak pressure up to 450 bar
A2FO
RE 91 401/09.00
Features
Fixed displacement pump A2FO of axial piston, bent axis designis made suitable for hydrostatic drives in open circuits.
Suitable for use in mobile or industrial applications.
Output flow is proportional to drive speed and displacement.
The drive shaft bearings are designed to give the service lifeexpected in these areas of operation.
Careful selection of the displacements offered, permit sizes to bematched to practically every application.
Favourable power / weight ratio
Compact and economical design
Optimum efficiency
One piece pistons with piston rings
-
Brueninghaus Hydromatik 2/20 A2FO
RE 91 401/09.00
Ordering Code / Standard Program(Ordering code size 5 see page 7)
A2F O / 6
Sizes 5...200: production Elchingen plant; sizes 250...1000: production Horb plant
= available = not available
1) only in connection with drive shaft bearings "L"2) threads of fixing screws are metric
= preferred program(preferred types see page 18)
Hydraulic fluidMineral oil (no code)HFB-, HFC-, HFD- sizes 10...200 (no code)fluids sizes 250...1000 1) E-
Axial piston unitBent axis design, fixed displacement A2F
Drive shaft bearings 10...200 250..500 710..1000Mechanical bearings (no code) Long-Life bearings L
Mode of operationPump, open circuit O
SizeDisplacement Vg (cm3)5 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Series6
Indexsizes 10...180 1size 200 3sizes 250...1000 0
Direction of rotationViewed on shaft end clockwise R
anti-clockwise L
Seals 10...200 250...1000NBR (nitril-caoutchouc) PNBR (nitril-caoutchouc), shaft seal in FKM (fluor-caoutchouc) NFKM (fluor-caoutchouc) V
Shaft end 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000Splined shaft ADIN 5480 ZParallel shaft with Bkey, DIN 6885 P
Mounting flange 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000ISO 4-hole BISO 8-hole H
Service line connections 2)A(B) SAE, at side 05S SAE, at rearA(B) threads at side 06S threads, at rearA(B) SAE, at rear 11S SAE, at rear
-
RE 91 401/09.00
A2FO 3/20 Brueninghaus Hydromatik
tmin = -40C tmax = +115C
5
10
4060
20
100200400600
100016002500 0 20 40 60 80 100-40 -20
opt.
16
36
5
1600
-40 -25 -10 10 30 50 90 115700
VG 22VG 32
VG 46VG 68
VG 100
Notes on the selection of the hydraulic fluid
In order to select the correct fluid, it is necessary to know the operatingtemperature in the tank (open circuit) in relation to the ambienttemperature.
The hydraulic fluid should be selected so that within the operatingtemperature range, the operating viscosity lies within the optimumrange (opt) (see shaded section of the selection diagram). Werecommend that the highest possible viscosity range should be chosenin each case.
Example: At an ambient temperature of XC the operatingtemperature is 60C. Within the operating viscosity range (opt; shadedarea), this corresponds to viscosity ranges VG 46 or VG 68. VG 68should be selected.
Important: The leakage oil (case drain oil) temperature is influencedby pressure and pump speed and is always higher than the tanktemperature. However, at no point in the circuit may the temperatureexceed 115C for sizes 5200 or 90C for sizes 2501000.
If it is not possible to comply with the above conditions because ofextreme operating parameters or high ambient temperatures pleaseconsult us.
FiltrationThe finer the filtration the better the achieved cleanliness level of thepressure fluid and the longer the life of the axial piston unit.
To ensure the functioning of the axial piston unit a minimumcleanliness level of
9 to NAS 163818/15 to ISO/DIS 4406 is necessary.
At very high temperatures of the hydraulic fluid (90C to max. 115C,not permissible for sizes 2501000!) at least cleanliness level
8 to NAS 163817/14 to ISO/DIS 4406 is necessary.
If above mentioned grades cannot be maintained please consultsupplier.
Direction of flow
clockwise rotation anti-clockwise rotation
S to B S to A
Symbol
Connections
A, B Service line ports
S Suction port
T Drain port
U Port for bearing flushing(sizes 250...1000)
Fluid
To review the application of A2FO pumps with the selected hydraulicfluid, detailed fluid compatibility and application data can be foundin data sheets RE 90220 (mineral oil), RE 90221 (environmentallyacceptable hydraulic fluids) and RE 90223 (fire resistant fluids, HF).
The fixed pump A2FO is not suitable for operation with HFA. Whenusing HFB-, HFC-, HFD- or environmentally acceptable hydraulic fluidspossible limitations for the technical data have to be taken intoconsideration. If necessary please consult our technical department(please indicate type of the hydraulic fluid used for your applicationon the order sheet).
Operating viscosity rangeIn order to optain optimum efficiency and service life, we recommendthat the operating viscosity (at operating temperature) be selectedfrom within the range:
opt = operating viscosity 16...36 mm2/s
referred to the tank temperature (open circuit).
Viscosity limits
The limiting values for viscosity are as follows:
Sizes 5...200
min = 5 mm2/s,short term at a max. permissible temperature of tmax = 115C
max = 1600 mm2/s,short term on cold start (tmin = -40C)
Sizes 250...1000
min = 10 mm2/s,short term at a max. permissible leakage oil temp. of tmax = 90
max = 1000 mm2/s,short term on cold start (tmin = -25C)
Please note that the max. fluid temperature is also not exceeded incertain areas (for instance bearing area).
At temperatures of -25C up to -40C special measures may berequired for certain installation positions. Please contact us forfurther information.
Selection diagram
Technical Data
T US
B (A)
temperature t (C)
fluid temperature range
visc
osity
(m
m2 /s
)
-
Brueninghaus Hydromatik 4/20 A2FO
RE 91 401/09.00
Case drain pressure
Shaft seal ring FKM (fluor-caoutchouc)
The lower the speed and the case drain pressure the higher the lifeexpectation of the shaft seal ring. The values shown in the diagramare permissible loads of the seal ring and shall not be exceeded.
With constant case pressure in the range of the max. permissiblecase pressure a reduction of the life expectancy of the seal ring willresult.
For a short period (t < 5 min.) for the sizes 5200 pressure loads upto 5 bar independent from rotational speeds are permissible.
Sizes 10...200
Shaft seal ring NBR (nitril-caoutchouc) sizes 5...200
For seal rings of NBR 33% reduced values for the max. permissiblehousing pressure pabs.max. are to be considered compared with sealsof FKM.
Special operation conditions may require limitations of these values.
Note:
- maximum permissible pump speeds are given in the table on page 5
- max. perm. casing pressure pabs. max ___ 10 bar (sizes 5...200)
___ 4 bar (sizes 250...1000)
- the pressure in the housing must be the same as or greater thanthe external pressure on the shaft seal
Working pressure range inletMinimum pressure at port S
pabs. min _______________________________________________________________ 0,8 bar
Working pressure range outletMaximum pressure at port A or B(Pressure data to DIN 24312)
Size 5 Shaft end B Shaft end C
Nominal pressure pN 210 bar 315 bar
Peak pressure pmax 250 bar 350 bar
Sizes 10...200 1) Shaft end A, Z 2) Shaft end B, P
Nominal pressure pN 400 bar 350 bar
Peak pressure pmax 450 bar 400 bar1) Attention: shaft end Z and P with drives of radial force loads atthe drive shaft (pinion V-belt drives) necessitate reduction of thenominal pressure to pN = 315 bar.
2) shaft end Z for size 56: pN = 350 bar, pmax = 400 bar
Sizes 250...1000
Nominal pressure pN 350 bar
Peak pressure pmax 400 bar
With pulsating loads above 315 bar we recommend using the modelwith splined shaft, standard version A (sizes 10200) or with splinedshaft Z (sizes 2501000).
Long-Life bearings (L) (sizes 250...1000)(for high life expectancy and use of HF-fluids)
The outer dimensions of the axial piston pumps are identical tostandard design (without long life bearings). The change fromstandard design to long life bearing system is possible. We recommendto apply bearing flushing at port U.
Temperature range of the shaft seal ring
The FKM shaft seal is admissible for a temperature range from-25C to +115C. For applications below -25C a NBR shaft seal isnecessary (admissible temperature range -40C to +90C) (specialdesign for sizes 250...1000).
Bearing flushing
For sizes 250...1000 bearing and housing flushing is possible throughport U.
Flushing flow (recommendation)
Size 250 355 500 710 1000
qflush (L/min) 10 16 20 25 25
Technical Data
Sizes 250...1000
speed n (rpm)
perm
. pre
ssur
e p a
bs. m
ax. (b
ar)
7000 80005000 600040002000 30000 10001
2
3
4
5
6
7
8
9
10
sizes 10, 12, 16
sizes 23, 28, 32
size 45
sizes 56, 63sizes 80, 90
sizes 107, 125
sizes 160, 180
size 200
perm
. pre
ssur
e p a
bs. m
ax. (b
ar)
speed n (rpm)
3
2,5
2
1,5
10 1000750 2000
3,5
500250 1500 17501250
4size 250
size 355
sizes 500
size 1000
sizes 710
-
RE 91 401/09.00
A2FO 5/20 Brueninghaus Hydromatik
2,01,81,61,41,21,00,80
1
2
3
4
speed n/nmaxNote:
- max. perm. speed nmax perm. (speed limit)- min. perm. pressure at port S- admissible values for the drive shaft seal
Maximum permissible speed with increased inlet pressurepabs at suction port S
inle
t pre
ssur
e p a
bs in
bar
Table of values (theoretical values, without considering mh and v; values rounded)Size 5 10 12 16 23 28 32 45 56 63 80
Displacement Vg cm3 4,93 10,3 12,0 16,0 22,9 28,1 32 45,6 56,1 63 80,4Max. speed 1) nmax rpm 5600 3150 3150 3150 2500 2500 2500 2240 2000 2000 1800Max. perm. speed with increased nmax perm. rpm 8000 6000 6000 6000 4750 4750 4750 4250 3750 3750 3350input pressure pabsMax. perm. output flow, at nmax2) qV max L/min 27 32 37 49 56 68 78 99 109 122 140Max. power p = 350 bar Pmax kW 14,5 3) 19 22 29 33 41 47 60 65 74 84at qv max p = 400 bar Pmax kW 22 25 34 38 47 53 68 75 84 96Torque constants TK Nm/bar 0,076 0,164 0,19 0,25 0,36 0,445 0,509 0,725 0,89 1,0 1,27Perm. torque p = 350 bar T Nm 24,7 3) 57 67 88 126 156 178 254 312 350 445
p = 400 bar T Nm 65 76 100 144 178 204 290 356 400 508Case volume L 0,17 0,17 0,17 0,20 0,20 0,20 0,33 0,45 0,45 0,55Moment of inertia J kgm2 0,00008 0,0004 0,0004 0,0004 0,0012 0,0012 0,0012 0,0024 0,0042 0,0042 0,0072about drive axisWeight (approx.) m kg 2,5 5,4 5,4 5,4 9,5 9,5 9,5 13,5 18 18 23
Size 90 107 1 25 160 180 200 250 355 500 710 1000
Displacement Vg cm3 90 106,7 125 160,4 180 200 250 355 500 710 1000Max. speed 1) nmax rpm 1800 1600 1600 1450 1450 1550 1500 1320 1200 1200 950Max. perm. speed with increased nmax perm. rpm 3350 3000 3000 2650 2650 2750 1800 1600 1500 1500 1200input pressure pabsMax. perm. output flow, at nmax2) qV max L/min 158 167 196 228 255 304 364 455 582 826 922Max. power p = 350 bar Pmax kW 95 100 117 135 152 181 219 273 350 497 554at qv max p = 400 bar Pmax kW 108 114 133 155 174 207 Torque constants TK Nm/bar 1,43 1,70 1,99 2,55 2,86 3,18 3,99 5,65 7,96 11,3 15,9Perm. torque p = 350 bar T Nm 501 595 697 889 1001 1114 1393 1978 2785 3955 5570
p = 400 bar T Nm 572 680 796 1016 1144 1272 Case volume L 0,55 0,8 0,8 1,1 1,1 2,5 3,5 7,8Moment of inertia J kgm2 0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 0,178 0,55 0,55about drive axisWeight (approx.) m kg 23 32 32 45 45 66 73 110 155 322 3361) The values shown are valid for an absolute pressure (pabs) of 1 bar at the suction inlet S and when operated on mineral oil.
By increase of the input pressure (pabs > 1 bar) the rotational speeds can be increased to the max. admissible speeds (speed limits) (see diagram).2) 3 % volumetric loss included 3) p = 315 bar
Calculation of size
Vg n vFlow qV = in L/min1000
Vg p 1,59 Vg pTorque T = = in Nm20 mh 100 mh
2 T n T n qV pPower P = = = in kW60 000 9549 600 t
Vg = geometric displacement per rev. in cm3
T = torque in Nmp = pressure differential in barn = speed in rpmv = volumetric efficiencymh= mech. -hyd. efficiencyt = overall efficiency
sizes 5...200
sizes 250...1000
Technical Data
-
Brueninghaus Hydromatik 6/20 A2FO
RE 91 401/09.00
Code explanation
a = distance of Fq from shaft shoulder
Fq max = max. perm. radial force at distance a(at intermittent operation)
Fax max = max. perm. axial force when stationaryor when axial piston unit is running at zero pressure
Fax perm./bar= perm. axial force/bar working pressure
The direction of the max. perm. axial force must be noted bysizes 5...200:
- Fax = increases bearing life
+ Fax = reduces bearing life(avoid if possible)
Output drive
Permissible axial and radial loads on drive shaft
The values given are maximum values and do not apply to continuous operation
Size 5 10 12 16 23 28 32 45 56 63 80
a mm 12 16 16 16 16 16 16 18 18 18 20
Fq max N 710 2350 2750 3700 4300 5400 6100 8150 9200 10300 11500
Fax max N 180 320 320 320 500 500 500 630 800 800 1000
Fax perm./bar N/bar 1,5 3,0 3,0 3,0 5,2 5,2 5,2 7,0 8,7 8,7 10,6
Size 90 107 125 160 180 200 250 355 500 710 1000
a mm 20 20 20 25 25 25 41 52,5 52,5 67,5 67,5
Fq max N 12900 13600 15900 18400 20600 22900 12001) 15001) 19001) 30001) 26001)
Fax max N +Fax max 1000 1250 1250 1600 1600 1600 4000 5000 6250 10000 10000
- Fax max 1000 1250 1250 1600 1600 1600 1200 1500 1900 3000 2600
Fax perm./bar N/bar 10,6 12,9 12,9 16,7 16,7 16,7 2) 2) 2) 2) 2)1) Axial piston unit in stationary or in bypass operation, please contact us when appearing higher forces!2) Please contact us!
Technical Data
Optimal force direction of Fq (valid for sizes 10...180)
By means of appropriate force directions of Fq the bearing load causedby inside rotary group forces can be reduced. An optimal lifeexpectation of the bearing can be reached.
F q
a -
+F ax
A B A B
opt=45 opt = 45
opt=70 opt = 70
clockwise rotationpressure at port B
clockwise rotationpressure at port B
anti-clockwise rotationpressure at port A
-
RE 91 401/09.00
A2FO 7/20 Brueninghaus Hydromatik
Unit Dimensions, Size 5
Detail Y
pN = 315 barpN = 210 bar
Shaft ends Connections
B, (A) Service line ports M18x1,5
S Suction port M22x1,5
T Drain port M10x1, both sides
A2F 5 6.0 7
Additional instructions in text form
Seals
The fixed pump A2F 5 is equipped with NBR-(nitril-caoutchouc) seals in standard design.
In case of need FKM- (fluor-caoutchouc) sealsplease indicate when ordering in clear text:
"with FKM-seals"
Axial piston unit
Bent axis design, fixed displacement A2F
Size
Displacement Vg (cm3) 5
Direction of rotationViewed on shaft end clockwise R
anti-clockwise L
Series
6.0
Shaft end
Parallel shaft with key DIN 6885 BTapered shaft with spigot and spring washer DIN 6888 C
Service line connections
Threads at side, metric 7
= preferred program(preferred types see page 18)
taper 1:10
Ordering Code / Standard Program - Size 5
B Parallel shaft withkey A4x4x20DIN 6885
C Tapered shaft with spigotand spring washer 3x5DIN 6888
51 80
4
74,558,517,5
8
T T
T S
B (A)
60
48,5
62
h8
25
70R 6
706,
4
75 0,1
Y
Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
-
Brueninghaus Hydromatik 8/20 A2FO
RE 91 401/09.00
Unit Dimensions, Sizes 10, 12, 16Before finalising your design, please request a certified drawing.
64,51220
6 5
108
T2
80
h6
553,5
T1
41,540
9545 45
R 10
959
100
55,5
93,5
147130,5
23,5R
48,5
167,5
69
18,2
B (A)
42,5 16
85
S
Note:For anti-clockwise rotation port
plate is rotated through 180
pN = 400 bar pN = 400 bar pN = 350 bar pN = 350 bar
Connections
B(A) Service line ports M22x1,5
S Suction port M33x2
T1,T2 Drain port (1 port plugged) M12x1,5
R Air bleed (plugged) M8x1
Shaft ends
Sizes 10, 12, 16
A Splined shaft, DIN 5480W 25x1,25x30x18x9g
Sizes 10, 12
Z Splined shaft, DIN 5480W 20x1,25x30x14x9g
Sizes 10, 12, 16
B Parallel shaft with key,AS 8x7x32, DIN 6885
Sizes 10, 12
P Parallel shaft with key,AS 6x6x32, DIN 6885
-
RE 91 401/09.00
A2FO 9/20 Brueninghaus Hydromatik
Unit Dimensions, Sizes 23, 28, 32Before finalising your design, please request a certified drawing.
1207
040,5
1318,2
60,71825
819
141
T2
19
10
0 h6
T140
55,5
11845 45
R 12
118
11
12548,5
169144
9R
61,5
19391
23,2
60 14
106
1947,6
22,2
B (A) S
Note:
For anti-clockwise rotation portplate is rotated through 180
pN = 400 bar pN = 400 bar pN = 350 bar pN = 350 bar
Connections
B(A) Service line ports SAE 1/2"420 bar (6000 psi) high pressure series
S Suction port SAE 3/4"350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged) M16x1,5
R Air bleed (plugged) M10x1
Shaft ends
Sizes 23, 28, 32
A Splined shaft, DIN 5480W 30x2x30x14x9g
Sizes 23, 28
Z Splined shaft, DIN 5480W 25x1,25x30x18x9g
Sizes 23, 28, 32B Parallel shaft with key,
AS 8x7x40, DIN 6885
Sizes 23, 28P Parallel shaft with key,
AS 8x7x40, DIN 6885
M8; 15 deep
M10; 17 deep
-
Brueninghaus Hydromatik 10/20 A2FO
RE 91 401/09.00
Unit Dimensions, Size 45Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
Connections
B(A) Service line ports SAE 3/4"420 bar (6000 psi) high pressure series
S Suction port SAE 1"350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged) M18x1,5
R Air bleed (plugged) M12x1,5
Shaft ends
50,8
19
23,8
60,32032
12
18
T2
12
5 h6
T140
158
1863
52
15045 45
R 16
150
13,5160
181
132
155
8011R
78
206
102
30B (A)
63,5 20
118
2552,4
26,2
S
A Splined shaft, DIN 5480W 32x2x30x14x9g
Z Splined shaft, DIN 5480W 30x2x30x14x9g
P Parallel shaft with key,AS 8x7x50, DIN 6885
pN = 400 bar pN = 400 bar pN = 350 bar
M10; 17 deep
M10; 17 deep
-
RE 91 401/09.00
A2FO 11/20 Brueninghaus Hydromatik
Unit Dimensions, Sizes 56, 63Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
Connections
B(A) Service line ports SAE 3/4"420 bar (6000 psi) high pressure series
S Suction port SAE 1"350 bar (5000 psi) standard series
T1,T2 Drain port (1 port plugged) M18x1,5
R Air bleed (plugged) M12x1,5
Shaft ends
50,8
1923,8
67,52032
10
12
5h6
18 169,5
40
T1
18
56
70
T2
45 45
R 16
150
150
13,5160
22514
2
87171
11R
78
19710
9
30B (A)
68 23
128
2552,4
26,2
S
pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar
Sizes 56, 63
A Splined shaft, DIN 5480W 35x2x30x16x9g
Size 56
Z Splined shaft, DIN 5480W 30x2x30x14x9g
Sizes 56, 63B Parallel shaft with key,
AS 10x8x50, DIN 6885
Size 56P Parallel shaft with key,
AS 8x7x50, DIN 6885
M10; 17 deep
M10; 17 deep
-
Brueninghaus Hydromatik 12/20 A2FO
RE 91 401/09.00
15 189,5
40
T1
15
61
83
T2
78,52032
10
14
0h6
45 45
R 16
165
165
13,5180
196
99
255
160
27,8
57,2
25
11R
85,5
223,5
122
29B (A) S
73 25
138
30,2
3258,7
Unit Dimensions, Sizes 80, 90Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
Connections
B(A) Service line ports SAE 1"420 bar (6000 psi) high pressure series
S Suction port SAE 1 1/4"280 bar (4000 psi) standard series
T1,T2 Drain port (1 port plugged) M18x1,5
R Air bleed (plugged) M12x1,5
Shaft ends
pN = 400 bar pN = 400 bar pN = 350 bar pN = 350 bar
Sizes 80, 90
A Splined shaft, DIN 5480W 40x2x30x18x9g
Size 80
Z Splined shaft, DIN 5480W 35x2x30x16x9g
Sizes 80, 90
B Parallel shaft with key,AS 12x8x56, DIN 6885
Size 80
P Parallel shaft with key,AS 10x8x56, DIN 6885
M12; 17 deep
M10; 17 deep
-
RE 91 401/09.00
A2FO 13/20 Brueninghaus Hydromatik
31,8(27,8)
32(25
)
66,7(5
7,2)
82,8
40
18212
T1
67
18852340
10
16
0 h6
T2
190
190
17,5
R 20
45 45
200
245
110
136
213
12R
98
27517
3
36,5S
89
B (A)
20
150
35,7
3869,9
Unit Dimensions, Sizes 107, 125Dimensions brackets for size 107 Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
Connections
B(A) Service line ports SAE 1 1/4" (1")420 bar (6000 psi) high pressure series
S Suction port SAE 1 1/2"210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged) M18x1,5
R Air bleed (plugged) M14x1,5
Shaft ends
pN = 400 bar pN = 400 bar pN = 350 bar pN = 350 bar
Sizes 107, 125
A Splined shaft, DIN 5480W 45x2x30x21x9g
Size 107
Z Splined shaft, DIN 5480W 40x2x30x18x9g
Sizes 107, 125B Parallel shaft with key,
AS 14x9x63, DIN 6885
Size 107P Parallel shaft with key,
AS 12x8x63, DIN 6885
M14; 19 deep(M12; 17 deep)
M12; 20 deep
-
Brueninghaus Hydromatik 14/20 A2FO
RE 91 401/09.00
66,7
32
31,8
T1
T2
19,5 233
77,5
12,5
95,5
40
932540
10
18
0 h6
210
210
17,5
R 20
45 45
224
237271
18812
1R
19,5
108
294
150
37,2
101
B (A)
15
180
35,7
4269,9
S
Unit Dimensions, Sizes 160, 180Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
Connections
B(A) Service line ports SAE 1 1/4"420 bar (6000 psi) high pressure series
S Suction port SAE 1 1/2"210 bar (3000 psi) standard series
T1,T2 Drain port (1 port plugged) M22x1,5
R Air bleed (plugged) M14x1,5
Shaft ends
pN = 400 bar pN = 400 bar pN = 350 bar pN = 350 bar
Sizes 160, 180
A Splined shaft, DIN 5480W 50x2x30x24x9g
Size 160
Z Splined shaft, DIN 5480W 45x2x30x21x9g
Sizes 160, 180
B Parallel shaft with key,AS 14x9x70, DIN 6885
Size 160
P Parallel shaft with key,AS 14x9x70, DIN 6885
M14; 19 deep
M12; 20 deep
-
RE 91 401/09.00
A2FO 15/20 Brueninghaus Hydromatik
3266,7
31,8
23710
2,5
20
0
15
15
T
T
-0,
029
25
1043240
9
92
75265
34116
9
236
236
250
22
4545
21R
121
100
319
32
10869,9
211
120,
7
90 SB (A)
Unit Dimensions, Size 200Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
Connections
B(A) Service line ports SAE 1 1/4"420 bar (6000 psi) high pressure series
S Suction port SAE 3 1/2"35 bar (500 psi) standard series
T Drain port (1 port plugged) M22x1,5
R Air bleed (plugged) M14x1,5
Shaft ends
B Parallel shaft with key,AS 14x9x70, DIN 6885
pN = 400 bar pN = 350 bar
Connections
B(A) Service line ports SAE 1 1/4"high pressure series
S Suction port SAE 2 1/2"standard series
T Drain port (1 port plugged) M 22x1,5
U Port for bearing flushing (plugged) M 14x1,5
Shaft ends
Z Splined shaft, DIN 5480W 50x2x30x24x9g
P Parallel shaft with key,AS 14x9x80, DIN 6885
pN = 350 bar pN = 350 bar
Unit Dimensions, Size 250Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
A Splined shaft, DIN 5480W 50x2x30x24x9g
124
246
280
22
246
45 45267
8250229
2582
309
105
1052
24 h8
8210
32630
66,732
T
T
U21
0B (A) 6350,8
118
88,912
S
31,8
172
329
B(A)
250
30
M16
M14; 19 deepM16; 24 deep
M14; 19 deep
M12; 17 deep
-
Brueninghaus Hydromatik 16/20 A2FO
RE 91 401/09.00
Unit Dimensions, Size 355Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
Connections
B(A) Service line ports SAE 1 1/2"high pressure series
S Suction port SAE 2 1/2"standard series
T Drain port (1 port plugged) M33x2
U Port for bearing flushing (plugged) M14x1,5
MA (B) Gauge port (working pressure) plugged M14x1,5
MS Gauge port (suction pressure) plugged M14x1,5
Shaft endsP Parallel shaft with key,
AS 18x11x100, DIN 6885
pN = 350 bar pN = 350 bar
Connections
B(A) Service line ports SAE 1 1/2"high pressure series
S Suction port SAE 3"standard series
T Drain port (1 port plugged) M33x2
U Port for bearing flushing (plugged) M18x1,5
MA (B) Gauge port (working pressure) plugged M14x1,5
MS Gauge port (suction pressure) plugged M14x1,5
Shaft ends
Z Splined shaft, DIN 5480W 70x3x30x22x9g
P Parallel shaft with key,AS 20x12x100, DIN 6885
pN = 350 bar pN = 350 bar
Unit Dimensions, Size 500Before finalising your design, please request a certified drawing.
Note:
For anti-clockwise rotation portplate is rotated through 180
A Splined shaft, DIN 5480W 60x2x30x28x9g
3208323,5
5014
2630
128
U T
280
h8
T83
350
28
128
102
198
18
335
335
170
2230
45
360
320
245
36,6 88,9
40 635060
79,4 B (A) S 50,8
250
MSMB
45
M18
22
192
375
360
400
375
2230
45
36,6
75405565
62 270
79,4 SB (A)
106,4
30
315
h8
111
142
220
112,
5
396
2630
T
361,550 98
14 27,5
142
TU
276
MSMB
M20
45
M16; 21 deep M12; 17 deep
M16; 24 deep M16; 24 deep
-
RE 91 401/09.00
A2FO 17/20 Brueninghaus Hydromatik
Unit Dimensions, Size 710Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
ConnectionsB(A) Service line ports SAE 2"
high pressure series
S Suction port SAE 4"standard series
T Drain port (1 port plugged) M42x2
U Port for bearing flushing (plugged) M18x1,5
MA (B) Gauge port (working pressure) plugged M14x1,5
MS Gauge port (suction pressure) plugged M14x1,5
Shaft ends
P Parallel shaft with key,AS 25x14x125, DIN 6885
pN = 350 bar pN = 350 bar
Z Splined shaft, DIN 5480W 90x3x30x28x9g
Connections
B(A) Service line ports SAE 2"high pressure series
S Suction port SAE 4"standard series
T Drain port (1 port plugged) M42x2
U Port for bearing flushing (plugged) M18x1,5
MA (B) Gauge port (working pressure) plugged M14x1,5
MS Gauge port (suction pressure) plugged M14x1,5
Shaft ends
Z Splined shaft, DIN 5480W 90x3x30x28x9g
P Parallel shaft with key,AS 25x14x125, DIN 6885
pN = 350 bar pN = 350 bar
Before finalising your design, please request a certified drawing.
Note:For anti-clockwise rotation port
plate is rotated through 180
Unit Dimensions, Size 1000
465
22
236
465
2230
45
500
450
15635
252
T
U
50710
2
183
183
400
h8
T14 41,550 131
486
1830
44,5 130,2
5085 70
100
SB (A) 77,8 34
0
96,8
344
MSMB
M24
45
22
236
465
450
500
465
2230
45
340
M24
45
35
40
156
183
279
143
512
2630
T
46850 131
14 41,5
0h8
183
TU 130,244,5
50 10085
96,8
70
77,8SB (A)
344
MB MS
M20; 30 deep M16; 24 deep
M20; 30 deep M16; 24 deep
-
Brueninghaus Hydromatik 18/20 A2FO
RE 91 401/09.00
Preferred Types
Type Ident-No.
A2F5.6.0B7 9404452
A2FO10/61R-PAB06 9424894
A2FO10/61R-PBB06 9610682
A2FO12/61R-PAB06 9420472
A2FO12/61R-PBB06 9610683
A2FO16/61R-PAB06 9411113
A2FO16/61R-PBB06 9411121
A2FO23/61R-PAB05 9427223
A2FO23/61R-PBB05 9610684
A2FO28/61R-PAB05 9425164
A2FO28/61R-PBB05 9610685
A2FO32/61R-PAB05 9410193
A2FO32/61R-PBB05 9410198
A2FO45/61R-PZB05 9411585
A2FO56/61R-PAB05 9425190
A2FO56/61R-PBB05 9610686
A2FO63/61R-PAB05 9408527
A2FO63/61R-PBB05 9408552
A2FO80/61R-PAB05 9424687
A2FO80/61R -PBB05 9610687
Type Ident-No.
A2FO90/61R-PAB05 9408467
A2FO90/61R-PBB05 9408472
A2FO107/61R-PAB05 9423259
A2FO107/61R-PBB05 9438282
A2FO125/61R-PAB05 9409641
A2FO125/61R-PBB05 9409642
A2FO160/61R-PAB05 9422192
A2FO160/61R-PBB05 9610688
A2FO180/61R-PAB05 9409371
A2FO180/61R-PBB05 9409358
A2FO200/63R-PAB05 2011993
Sizes 5...200: production Elchingen plantSizes 250...1000: production Horb plant
Please state type and ident-no. when ordering!
-
RE 91 401/09.00
A2FO 19/20 Brueninghaus Hydromatik
Installation and Commissioning Guidelines
General
At start-up and during operation the pump housing has imperativelyto be filled up with hydraulic fluid (filling of the case chamber). Start-up has to be carried out at low speed and without load till the systemis completely bleeded.
At a longer standstill the case may discharge via operating line. Atnew start-up a sufficient filling of the housing has to be granted.
The leakage oil in the housing has to be discharged to the tank viahighest positioned case drain port. The min. suction pressure at portS should not fall below 0,8 bar absolute.
Installation position
Optional
Installation below tank levelPumps below min. oil level in the tank (standard)
Fill up axial piston pump before start-up via highest positionedcase drain port (note for the shaft on top installation position:fill until oil starts escaping from air bleed port R or U).
Recommendation: Fill up suction lines
Operate pump at low speed (igniton speed) till pump system iscompletely filled up
Minimum immersion depth of the suction line or drain line inthe tank:200 mm (relative to the min. oil level in the tank).
Installation on top of tank level
Pump on top of min. oil level in the tank
Actions as installation below tank level
Installation position 1 and 2:If the pump is left at standstill for a long period, the oil in thehousing chamber may fully drain out through the operatinglines (air entering via the shaft seal). Consequently, onrestarting, the bearings will be insufficiently lubricated. Youshould therefore refill the axial piston unit via the highestpositioned drain port before restarting (Installation position 2:air bleed via port R or U).
Installation position 2 (shaft on top)In this installation position, the bearings will be insufficientlylubricated even if the housing chamber is only partially drained.To prevent oil draining via the drain port, insert a check valve inthe drain line (opening pressure 0.5 bar).
Note: min. admissible presssure at port S (min. suction pressure)
T2
T2
R (U)
T1
T1
S
S
S
S
T2
T2
R(U)
T1
T1
S
S
S
S
0,5
bar
*2
1
*
-
All rights reserved Subject to revision 20/20 A2FO
RE 91 401/09.00
The specified data is for product descriptionpurposes only and may not be deemed to beguaranteed unless expressly confirmed in thecontract.
Brueninghaus Hydromatik GmbH
Elchingen PlantGlockeraustrae 2 D89275 ElchingenPhone +49 (0) 73 08 82-0Telefax +49 (0) 73 08 72 74
Horb PlantAn den Kelterwiesen 14 D72160 HorbPhone +49 (0) 74 51 92-0Telefax +49 (0) 74 51 82 21
Internet: www.rexroth.com/brueninghaushydromatik / E-Mail: [email protected]
TitleIndexFeaturesOrdering CodeTechnical DataFluidSelection diagrampressure rangeTable of values
Ordering Code size 5Unit Dimensionssize 5size 10, 12, 16size 23, 28, 32size 45size 56, 63size 80, 90size 107, 125size 160, 180size 200size 250size 355size 500size 710size 1000
Preferred Types