recent challenges and advances on - gamaco · •classical applications in buildings : pt slabs...
TRANSCRIPT
![Page 1: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/1.jpg)
Recent challenges and advances on PRESTRESSED CONCRETE design and construction
FIB Belgium Colloquium – June 5th 2013
François LEPERS, IrCEO of GAMACO sa
![Page 2: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/2.jpg)
• Classical applications in buildings : PT SLABS
▫ Flat slabs
▫ Other PT slab structures
▫ examples
• Other particular cases
Recent challenges and advances on
prestressed concrete design and construction
![Page 3: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/3.jpg)
PT slabs (1)
• Typical structure : flat slabs▫ bi-directional behavior – no beams
▫ Classical Span/depth ratio : L/30 to L/45
▫ Admissible spans : 6 to 12 m
▫ Common applications : office buildings, hotels, car parks, commercial center,…
![Page 4: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/4.jpg)
PT slabs (2)• Other PT slab possibilities
▫ Larger spans (up to 16m) ; heavy loadings, self-weigth reduction
![Page 5: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/5.jpg)
PT slabs (3)• AZ Groeninge – Kortrijk – 110 000m²
▫ Flat slab 250mm
▫ Typical grid : 8.1m x 8.1m
![Page 6: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/6.jpg)
PT slabs (4) • Euromed – Marseille – 45 000 m²
![Page 7: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/7.jpg)
PT slabs (5) • Parking casino Aix-en-Provence – 28 000 m²
▫ Grid 16.0m x 7.0m – waffle slab 400 mm
![Page 8: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/8.jpg)
PT slabs (6) • Commercial center and parking LECLERC – Roques (Toulouse) 35 000 m²
▫ Grid 16.0m x 8.0 m▫ PT beams 1000 x 600 mm▫ PT slab 200mm
![Page 9: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/9.jpg)
PT slabs (7) • Public Car Park – La Garde (Toulon) - 12500 m²
▫ Grid 16.0m x 6.0 m
▫ Parking : flat slab 350 mm
▫ Roof ( DL+LL = 12+10kPa) : 550 mm
![Page 10: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/10.jpg)
Recent challenges and advances on
prestressed concrete design and construction
• Classical applications in buildings : PT SLABS
• Other particular cases:
▫ Load transfer structures
▫ Long cantilevers
![Page 11: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/11.jpg)
Load transfer structures (1)• Cité Judiciaire - Luxemburg
▫ Bi-directional flat slab
▫ Max spans : 17.0m
▫ Slab thickness = 130cm
![Page 12: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/12.jpg)
Load transfer structures (2)• Auditorium – Bordeaux
o Transfer beams - spans 32m.
o Section : 2.0m x 2.2m
![Page 13: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/13.jpg)
Long cantilevers (1)• Residential building – Temse
▫ Flat slab 240mm – cantilever = 4.0m
![Page 14: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/14.jpg)
Long cantilever(2)• Hotel de région - Toulouse
▫ Public office building▫ PT truss beam▫ Cantilever 6.0 m
![Page 15: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/15.jpg)
Long cantilevers (3)
• Twarda tower – Warsaw – Poland▫ High-rise building (160m)▫ 44 levels▫ Cantilever 11m ▫ PT Hangers
![Page 16: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/16.jpg)
Long cantilevers (4)
• Maison du Savoir - Luxemburg▫ PT slabs and PT Walls▫ 2 cantilevers : 25m each▫ 1 central span : > 50m
![Page 17: Recent challenges and advances on - Gamaco · •Classical applications in buildings : PT SLABS Flat slabs Other PT slab structures examples •Other particular cases Recent challenges](https://reader030.vdocument.in/reader030/viewer/2022040120/5e71f1b92425da22671f8202/html5/thumbnails/17.jpg)
Recent challenges and advances on prestressed concrete design and construction
• Classical PT slab structure :
o economies in concrete, steel, CO2, €
• Architectural challenges
o Prestressed concrete can be an efficient solution
Platinium Towers (Warsaw – Poland)
Place de l’Université 251348 Louvain La Neuve
T 010/ [email protected]
Harensesteenweg 299180 Vilvoorde
T 02/[email protected]