recent improvements in rapid column separation methods at srs
DESCRIPTION
Recent Improvements in Rapid Column Separation Methods at SRS. S. L. Maxwell, III, D. J. Fauth, R. C. Henderson, J. J. Smiley, S. R. Johnson Westinghouse Savannah River Site. Recent Improvements. SRS Environmental Monitoring lab faster water and air filter analysis for actinides - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/1.jpg)
Recent Improvements in Rapid Column Separation Methods at SRS
S. L. Maxwell, III, D. J. Fauth, R. C. Henderson, J. J. Smiley, S. R. Johnson
Westinghouse Savannah River Site
![Page 2: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/2.jpg)
Recent Improvements
• SRS Environmental Monitoring lab– faster water and air filter analysis for actinides
– improved soil-fecal sludge analyses (wastewater treatment plant samples)
• SRS Bioassay lab– improved Pu-Np column extraction for urine (better Pu
stripping/less volume)
– faster fecal analysis method (no microwave)
• Central Laboratory (process lab)– improved Pu, Np in HEU and LEU samples
– TEVA + Pu-236 tracer
![Page 3: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/3.jpg)
SRS Environmental Monitoring Lab• Vacuum box systems and stacked cartridges
• Significant cost and time savings vs. gravity flow
• Tested both stacked UTEVA+ TRU and TEVA+TRU methods– both methods work very well; much faster than gravity flow
– eliminated evaporation of Am fraction: use 5 mL con HF
– use 50 ug cerium instead of 100 ug to improve peak resolution
![Page 4: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/4.jpg)
SRS Environmental Monitoring Lab
• Showed stacked TEVA+TRU can be used on water samples – just like urine method- no iron interference – may have some advantages for air filters (Po-210 interference)
• Po-210 can interfere with U-232 on UTEVA
– allows Pu AND Np together on TEVA
– use Ti (III) reductant in Pu strip from TEVA when performing cerium fluoride microprecipitation
![Page 5: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/5.jpg)
Pu, Np/Am, U, Sr on TEVA/TRU RESIN (Water/Air filters)
Rinse20 mL 3M HN03
Th Removal3mL 9M HCI/25mL
8MHCI
Pu Elution20mL
0.10M HCl - 0.05MHF - 0.03M TiCl3
1) Redissolve in 10 mL 3M HN03 - 0.5M Al(NO3)3
2) Add 0.5 mL 1.5M Sulfamic Acid + 1 mL 1.5M Ascorbic Acid3) Add 1 mL 3.5M Sodium Nitrite
Remove TRU cartridge:1) Elute Am with
15mL 4M HCI2) Elute U with
10mL 0.1M ammoniumbioxalate
2mL TEVA Resin(50-100 um)
2.0mL TRU-Resin(50-100 um)
Collect, evaporate, dissolve in 6M HNO3Sr Resin
Alpha spectrometry
Cerium fluoride
Add 0.5 mL 3M sodium nitrite
![Page 6: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/6.jpg)
Pu-242 Tracer Recoveries
1000 mL water samples/ Pu-242 tracer= 4.40 dpm
Calcium phosphate precipitation
% Pu242 Recovery % Pu242 Recovery
UTEVA+TRU Method TEVA+TRU Method
1) 101 1) 99.3
2) 106 2) 105
3) 106 3) 105
4) 108 4) 109
5) 98.6
6) 102
Avg. = 105% (2.8% @1s) Avg. = 103% ( 3.8% @1s)
![Page 7: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/7.jpg)
![Page 8: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/8.jpg)
![Page 9: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/9.jpg)
Am-243 Tracer Recoveries
1000 mL water samples/ Am-243 tracer= 3.84 dpm
Calcium phosphate precipitation
% Am-243 Recovery % Am-243 Recovery
UTEVA+TRU Method TEVA+TRU Method
1) 105 1) 98.4
2) 100 2) 99.0
3) 91.5 3) 107
4) 98.7 4) 100
5) 102 5) 106
6) 106 6) 105
Avg. = 101% (5.2% @1s) Avg. = 103% ( 3.8% @1s)
![Page 10: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/10.jpg)
![Page 11: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/11.jpg)
![Page 12: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/12.jpg)
U-232 Tracer Recoveries1000 mL water samples/ U-232 tracer= 5.45 dpm
Calcium phosphate precipitation
% U-232 Recovery % U-232 Recovery
UTEVA+TRU Method TEVA+TRU Method
1) 92.9 1) 87.5
2) 98.2 2) 93.5
3) 96.2 3) 97.4
4) 94.9 4) 92.4
5) 91.6 5) 94.0
6) 93.2
Avg. = 94.5% (2.6% @1s) Avg. = 93.0% ( 3.8 % @1s)
![Page 13: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/13.jpg)
SRS Environmental Monitoring Lab
• Actinides in soil-fecal samples – dissolution and column flow problems with current method
– need total dissolution/eliminate flow problems & low uranium
– use Diphonix resin technology as in bioassay lab• Initial testing encouraging
• Use sodium peroxide/sodium hydroxide fusion (Zr crucibles)
• Precipitate actinides as hydroxides; redissolve in HCL-HF/also boric acid fraction
• 4 mLs Diphonix Resin + small volume HEDPA strip (15-20 mLs)
• Faster HEDPA destruction method (no microwave)– modified Fenton’s Reagent method
• Routine size Eichrom columns
![Page 14: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/14.jpg)
Diphonix Stripping-HEDPA
0.5M HEDPA % Pu242 % U232
Strip Volume Tracer Tracer
1) 3 mL resin 15 mL 104 96
2) 4 mL resin 15 mL 99 97
3) 4 mL resin 20 mL 105 84
4) Direct -HEDPA 20 mL 113 113
Avg= 105 % 98 %
Redissolve in 10 mLs 6M HNO3 and 10 mls 2.5M aluminum nitrate (to avoid
phosphate interference), then TEVA+ TRU Column extraction
![Page 15: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/15.jpg)
Soil-Fecal Sludge Samples
Pu-242 Pu-238 Pu-239/240
% Recovery pCi/g pCi/g
1) 101% 0.435 2.18
2) 69 % 0.484 2.33
3) 84% 0.442 2.07
4) 49 % 0.448 2.39
Avg= 76% 0.452 (4.8% @1s) 2.24 (6.5% @1s)
![Page 16: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/16.jpg)
Soil-Fecal Sludge Samples
U-232 U-234 U-235 U-238
% Recovery pCi/g pCi/g pCi/g
1) 56% 6.16 0.355 5.56
2) 75 % 5.44 0.351 4.76
3) 74% 5.28 0.346 5.04
4) 98 % 4.44 0.253 3.98
Avg= 76% 5.33 (13% @1s) 0.326 (15% @1s) 4.84 (14% @1s)
![Page 17: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/17.jpg)
Soil-Fecal Sludge Samples
Am-243 Am-241 Cm-244
% Recovery pCi/g pCi/g
1) 73% 0.746 0.506
2) 53 % 0.684 0.506
3) 64% 0.620 0.462
4) 38 % 0.670 0.378
Avg=57% 0.679 (7.6% @1s) 0.464 (13% @1s)
![Page 18: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/18.jpg)
Bioassay Lab Improvements
• Actinides and Sr-90 in urine– stacked TEVA+TRU Resin cartridges with vacuum boxes
– Pu-236 tracer for Pu and Np at same time
– Pu, Np (TEVA) and U, Am (TRU)
– Sr (Sr Resin)
• Pu stripping improvement:– improved Pu stripping with rongalite instead of iodide in strip
solution (less volume/faster flow rate)
– rongalite (sodium formaldehyde sulfoxylate)
– compatible with electroplating
– adjust bisulfate added for sulfate added from rongalite decomposition (2.5 mLs 10 % bisulfate instead of 3 mLs)
![Page 19: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/19.jpg)
Urine Batch: Calcium Phosphate Precipitation
![Page 20: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/20.jpg)
Pu, Np/Am, U, Sr on TEVA/TRU RESIN (URINE)
Rinse20 mL 3MHN03
Th Removal5mL 9M HCI/25mL 8M HCI
Pu Elution20mL
0.10M HCl - 0.05M HF - 0.015M Rongalite
1) Redissolve in 12 mLs of 3M HN03 - 1M Al(NO3)3
2) Add 0.5 mL 1.5M Sulfamic Acid + 2 mls 1.5M Ascorbic Acid3) Add 2 mLs 4M Sodium Nitrite
Remove TRU cartridge:1) Elute Am with
15mL 4M HCI2) Elute U with
20mL 0.1M ammoniumbioxalate
2mL TEVA Resin(50-100 um)
2.0mL TRU-Resin(50-100 um)
Collect, evaporate, dissolve in 6M HNO3Sr Resin
Electrodeposition
4mls 0.02M H2SO4 + 3mls 16M HN03
Evaporate/ash
![Page 21: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/21.jpg)
TEVA+ TRU Stacked Column: Pu, Np, U, Am
![Page 22: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/22.jpg)
TRU Cartridge: U, Am Stripping
![Page 23: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/23.jpg)
SR Cartridge: Sr-90 Separation
![Page 24: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/24.jpg)
![Page 25: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/25.jpg)
![Page 26: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/26.jpg)
Pu-236 Recoveries-UrineUsing TEVA/Rongalite
Pu-236=0.426 dpm500 mL urineAvg Recovery=99%
0
20
40
60
80
100
120
140
160
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
![Page 27: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/27.jpg)
Spiked Urine Samples: Rongalite Test
Known values: Avg. measured: Pu-238 =0.110 dpm/L Pu-238 =0.143 dpm/LPu-239 =0.857 dpm/L Pu-239 =0.848 dpm/LNp-237=0.535 dpm/L Np-237=0.508 dpm/L
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1 2 3 4 5 6 7 8 9 10
Pu-238
Np-237
Pu-239
![Page 28: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/28.jpg)
Bioassay Lab Improvements• Bioassay: fecal method
– wet ashing and dissolution in HCL-HF
– Diphonix Resin
– TEVA+TRU Resin
– cartridges not stacked due to possible iron
– previously evaporated load plus rinse from TEVA then redissolved, added reductant and loaded onto TRU
– Pu, Np (TEVA) and U, Am (TRU)
– Sr (Sr Resin)
![Page 29: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/29.jpg)
Recent Improvements in Fecal Method
• Improvements:– no evaporation of load solution from TEVA to save time
• collect load plus minimal rinse from TEVA
• add sulfamic acid + ascorbic acid and load to TRU resin
– improved Pu stripping with rongalite instead of iodide in strip solution
– Also testing:• use of HEDPA strip of Diphonix instead of microwave (minimize
HEDPA to minimize phosphate and increase Al in final load solution)
• Use sodium peroxide/sodium hydroxide fusion instead of wet ashing
![Page 30: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/30.jpg)
![Page 31: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/31.jpg)
Microwave Digestion of Diphonix: Fecal Method
![Page 32: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/32.jpg)
5
Testing using 15 mL strip with 0.04M Rongalite; acidify to 3M HNO3, add Al(NO3)3 and nitrite and load to second TEVA column
Collect load and small rinseONLY: Eliminated evaporation
![Page 33: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/33.jpg)
Pu on TEVA Resin-Fecal(2nd Column to Remove all Th-228)
• Adjust acidity of 15 mL strip solution to 3M HNO3 using 4 mLs 16M HNO3• Add 1 mL of 2.5M aluminum nitrate• Add 1mL 3.5 M Sodium Nitrite
Th Removal3mL 9MHCI/7mL
8MHCIRinse
10mL 3MHN03
Pu Elution20 mL
0.10MHC1 - 0.05MHF - 0.015M rongalite
1mL TEVA Resin
![Page 34: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/34.jpg)
Process Lab Improvements
• Process samples to support HEU Blenddown processing
• Improvements:– Pu and Np are key product specification measurements
– Pu-236 tracer for Pu and Np on TEVA resin in HEU and LEU process solutions
– 1 mL TEVA cartridges to ensure total Th-228 removal (separated twice on TEVA)
– use Ti (III) reductant in Pu strip from TEVA
![Page 35: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/35.jpg)
![Page 36: Recent Improvements in Rapid Column Separation Methods at SRS](https://reader035.vdocument.in/reader035/viewer/2022062520/56815971550346895dc6b471/html5/thumbnails/36.jpg)
Summary
• SRS Environmental Monitoring lab work– Vacuum box technology reduced method time by about 50%
– Diphonix-HEDPA may help with difficult soil-fecal samples
• Bioassay lab– Improved Pu stripping using rongalite (85% to 99%)
– HEDPA to eliminate microwave in fecal analysis
• Process lab– Pu-236 tracer use for Pu, Np in process lab on high uranium
samples