recommendation for elimination of lead filling in target flanges
TRANSCRIPT
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
1/10
RECOMMENDATION FOR
ELIMINATION OF LEAD FILLING
IN TARGET FLANGES
TECHNICAL REPORT TR1201
AWHEM publications may be used by anyone desiring to do so. Every effort has been made by the
Association to assure the accuracy and reliability of the data contained in them; however, the Association
makes no representation, warranty, or guarantee in connection with this publication and hereby expressly
disclaims any liability or responsibility for loss or damage resulting from its use or for the violation of any
federal, state or municipal regulation with which this publication may conflict.
Association of Well Head
Equipment Manufacturers Post Office Box 1166 Bellaire, Texas 77401
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
2/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges
Issue Date:
March 13, 2012
AWHEM
RECOMMENDATION FOR
ELIMINATION OF LEAD FILLING
IN TARGET FLANGES
ISSUED BY:
ASSOCIATION OF WELL HEAD
EQUIPMENT MANUFACTURERSPOST OFFICE BOX 1166 BELLAIRE, TEXAS 77401
This document submitted for industry acceptance. We solicit any corrections, revisions and comments that you may offer.
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
3/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 2
INDEX
1. Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Example of Worst Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Example of Pressure Line with Cushions but no Target Flanges . . . . . . . . . . 4
4. Example of Pressure Lines with Lead Filled Target Flanges . . . . . . . . . . . . 5
5. Examples of Pressure Lines with Cushion Target Flanges . . . . . . . . . . . . . 6
6. Examples of Pressure Lines with Internal Cushion Space and Blind Flanges . . . . 7
7. Examples of Lead Filled Target Flange and Cushion Flange closing ManifoldBuffer Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8. Examples of Internal Cushion Space and Blind Flange Closing Manifold Buffer
Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9. Conclusion and Recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . 9
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
4/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 3
1. Purpose
This document shall demonstrate the absence of need for lead filled Target Flanges used inhigh-pressure manifold systems.
2. Example of Worst Case
When manifolding containing flowing fluid under pressure makes an abrupt 90 elbow turn,the downstream wall of the turn presents a target to the fluid flow. High speed, high
pressure fluid will erode the downstream wall of the elbow as it blasts against the wall.
Such an elbow can experience complete wash-out through this wall. See illustrations below:
Welded Line Fig. 1A
Downstream
Weld endElbow
In flowline
Upstream
Assembled Fitting Line Fig. 1B
Downstream
Studded flangeElbow
In flowline
Upstream
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
5/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 4
3. Example of Pressure Lines with Cushions, but no Target Flanges
Designers of piping and manifold systems may reduce the likelihood of erosion in such 90
turns by providing a cushion where the fluid blast would normally encounter the wall.
Welded Line Fig. 2A
Downstream
Weld end elbow made from awelded tee with one end of therun blanked off, leaving acushion space below theoutlet branch-off.
Upstream
Assembled Fitting Line, Fig. 2B Assembled Fitting Line, Fig. 2C
Downstream Downstream
Upstream
Upstream
Flanged elbow in flowline.
The elbow, made with extra length,has a cushion cavity
Studded flange elbow in flowline.
The elbow, made with extralength, has a cushion cavity
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
6/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 5
4. Example of Pressure Line with Lead Filled Target Flanges
Assembled Fitting Line, Fig. 3A Assembled Fitting Line, Fig. 3B
Downstream
Downstream
Upstream
Upstream
Flanged tee in flowline.
The end of the tee run closed with alead filled target flange.
(Note the cushion before the target
flange)
Studded flange tee in flowline.
The end of the tee run closedwith a lead filled target flange.
(Note the cushion before the
target flange)
Some believe that lead filling of the cavity (counter bore) of a target flange provides resistance to
the cutting force of high velocity abrasive fluid that may pass through a manifold system duringa well control event.
Caution: A problem can occur if the lead filling in the cavity of a target flange escapes the cavity
and moves into the flow bore blocking the flow.
The use of a Target Flange assumes a place to put the flange facing the flow of fluid, but the
placement of the Target Flange requires a fitting with an outlet requiring closure. Such a
fitting, by its configuration, will always provide a cushion space within its body. All of thefollowing illustrations will demonstrate this fact.
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
7/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 6
5. Example of Pressure Lines with Cushion Target Flanges
Assembled Fitting Line, Fig. 4A Assembled Fitting Line, Fig. 4B
Downstream Downstream
Upstream
Upstream
Flanged tee in flowline.
The end of the tee run closed with acushion flange (flange has acounterbore cavity).
(Note the cushion before the cushionflange)
Studded flange tee in flowline.
The end of the tee run closedwith a cushion flange (flangehas a counterbore cavity).
(Note the cushion before thecushion flange)
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
8/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 7
6. Example of Pressure Lines with Internal Cushion Space and Blind Flanges
Assembled Fitting Line, Fig. 5A Assembled Fitting Line, Fig. 5B
Downstream Downstream
Upstream
Upstream
Flanged tee in flowline.
The end of the run closed with aconventional blind flange. The cavitybefore the blind flange provides a fluidfilled cushion below the outlet branch-off.
(Note the cushion before the blindflange)
Studded flange tee in flowline.
The end of the run closed witha conventional blind flange.The cavity before the blindflange provides a fluid filledcushion below the outletbranch-off.
(Note the cushion before theblind flange)
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
9/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 8
7. Example of Lead Filled Target Flange and Cushion Flange closing a Manifold BufferChamber
Target flange opposite the fluid blast on a Buffer Chamber Assembled Buffer
Chamber, Fig. 6A
Discharge line toGas Buster, pit, etc.
Incoming line from choke(Note the cushion before the target flange)
Target flange opposite the fluid blast on a Buffer Chamber Assembled BufferChamber, Fig. 6B
Discharge line toGas Buster, pit, etc.
Incoming line from choke(Note the cushion before the cushion flange)
-
8/12/2019 Recommendation for Elimination of Lead Filling in Target Flanges
10/10
AWHEM Recommendation For Elimination of Lead Filling in Target Flanges 9
8. Examples of Internal Cushion Space and Blind Flange closing Manifold Buffer Chamber
9. Conclusion and Recommendation
An empty fluid cushion cavity in a manifold system appears to work just as well as a cavity filled
with lead. When the system designer has provided a fluid cushion below the turn, we have never
observed erosion on used flanges with or without a cavity and with or without lead filling.
In the examples shown above, of studded face and open face connected equipment, conventional
blind flanges will work as well as cushion flanges or lead filled target flanges.
In the interest of health and safety in the short run, and avoidance of introducing excessive lead
into our future steel scrap pool, AWHEM recommends discontinuance of lead filling of flange
cavities and relying instead on the common practice of having a cushion cavity below (or inthe direct path of the fluid blast) for all 90 abrupt turns in high pressure manifold systems.
Target flange opposite the fluid blast on a Buffer Chamber Assembled BufferChamber, Fig. 7A
Discharge line toGas Buster, pit, etc.
Incoming line from choke(Note the cushion before the blind flange)