red sky e-brochure nov2019€¦ · 11/12/2019 · &/$03 3lsh &odps .lw 6)&% 6dihw\...
TRANSCRIPT
Red Sky Lighting manufactures premier harsh and hazardous location LED lighting fixtures. From food processing plants to underground mining tunnels, oil rigs to bulk carriers, petrochemical plants to steel mills, our lights are designed to keep working through the toughest environments.
SeriouslySafe Lights
Hazardous Location Lighting Basics
Class I: GasesAreas in which flammable gases or vapors in the air in sufficient quantities to ignite or explode.
Class II: DustAreas in which combustible dust may be suspended in the air or accumulates on electrical equipment in quantities sufficient to ignite or explode.
Class III: FibersAreas in which easily ignitable fibers or flyings are present. Typically fibers and flyings are not suspended in the air, but can collect around machinery or on lighting fixtures.
Class I: GasesGroup A - AcetyleneGroup B - HydrogenGroup C - EthyleneGroup D - Propane
Class II: DustsGroup E - Electrically conductive dustGroup F - Carbonaceous dustGroup G - Agricultural and polymer dust
CLASSES
Division 1: Always PresentAreas in which ignitable concentrations of hazards exist under normal operation conditions and/or where hazard is caused by frequent maintenance or repair work or frequent equipment failure.
Division 2: Not Normally PresentAreas in which ignitable concentrations of hazards are normally in closed containers or closed systems. Hazards may be present due to accidental rupture or breakdown of such containers or systems.
DIVISIONS GROUPS
IEC publication 60079-10 uses Zones to define the guidelines for classifying hazardous areas. Zone 0 - Areas where explosive gas atmosphere is continuously present or present for long periods of time.
Zone 1 - Areas where explosive gas atmosphere is likely to occur in normal operation or can be expected to be present frequently.
Zone 2 - Areas where explosive gas atmosphere is not likely to occur and if it does, it will only be present for a short period of time.
Zone 20 - Areas in which a combustible dust, as a cloud, is present continuously or frequently during normal operations in sufficient quantities to produce an explosive mixture.
Zone 21 - Areas in which a combustible dust, as a cloud, is likely to occur during normal operations in sufficient quantities to produce an explosive mixture.
Zone 22 - Areas in which combustible dust, as a cloud, is not likely to occur, but may occur infrequently and persist for only short periods of time.
IEC ZONE CLASSIFICATIONS
FOR MORE INFORMATION - EMAIL: [email protected]
COMPARISON
HazardousMaterial
Gas orVapor
Dust
Fibers or Flyings
NEC U.S.Standards
Class I,Division 1
Class I,Division 2
Class II,Division 1
Class II,Division 2
Class III,Division 1
Class III,Division 2
IECStandards
Zone 0, 1
Zone 2
Zone 20
Zone 22
No Equivalent
No Equivalent
UL STANDARDS
Number Title
844 Lighting fixtures for use in hazardous areas
924 Emergency lighting and power equipment
1598 Lighting fixtures approved for ordinary locations
1598A Lighting approved for use on marine vessels. Salt water corrosive rated.
8750 LED safety
For complete Information, refer to the National Electric Code (NEC)
INGRESS PROTECTION (IP) CODES
™
®
First Number: Solid Objects Second Number: Liquids
1(833)-4REDSKYwww.redskylighting.com
0 No protection1 Objects greater than 50mm2 Objects greater than 12.5mm3 Objects greater than 2.5mm4 Objects greater than 1mm5 Dust protected6 Dust proof
0 No protection1 Vertically dripping2 Dripping up to 15°3 Limited spraying4 Splashing from all directions5 Hosing jets from all directions6 Strong hosing jets from all directions7 Temporary immersion8 Continuous immersion9K Steam-jet cleaningIP Codes referred to on the following page.
™
®
Corporate Office:410 Main St Racine, WI, 53403Phone: 1 (833) [email protected]
ENCLOSURE TYPES
20
22
55
24
55
66
66
52
67
68
54
54
54
Fixture Use
1
2
3
3R
4
4X
5
6
6P
7
8
9
10
12
13
Type
FOR HAZARDOUS LOCATION LED LIGHTING CALL (833) 4REDSKY
UL 844
UL 844
UL 844
UL 844
Manufacturing Facility:5301 21st St.Racine, WI, 53406Phone: 1 (844) 4HAZLOCwww.redskylighting.com
T - CODES
Maximum
Temperatures
°C °F
Temperature Class
(T-Code)
UL 844
Block Series
Linear Tuff Series
Round Series
Block-Mini series
Linear Series
Flood/High bay Linear Area Linear Area
FEATURED PRODUCTS
Certifications and RatingsBlock Series
Dimensions
Rated up to CID1, featuring 130 lumens per watt, three power options, and three available beam angles; the Block Series brings versatility, design excellence, and durability to hazardous location lighting. The Block Series is suitable when flammable gases, corrosive vapors, combustible dusts, and other hazards are present.
Specifications
Class I Division 1, Groups C,D Class I Division 2, Groups A,B,C,D
Class II Division 2, Groups F,GClass III
CSA C22.2 No. 137-M1981; 30-M1986CSA C22.2 No. 25-1966
CSA C22.2 No. 250.0-08; 250.13-14 UL 844 Hazardous Locations
UL 1598A Marine VesselsUL 1598 Wet Locations
UL 8750 LED Safety IP66
DLC (Contact Us)ABS (pending)
Voltage/Frequency
Power Factor
THD
Ambient Temperature
T-Code Rating
Warranty
Construction
Lens Material
Hardware
Finish
Connection
Color Rendering Index
L70
Available Beam Angles
Power
Lumen Output
Surge Protection
>99%
-40°F to 140°F (-40°C to 60°C)
Die-cast Aluminum
Tempered Glass
Marine Grade Stainless Steel
Thermoset Powdercoat
3/4” NPT
Ra>70
4KvA
<10%
>50,000 Hours
AC100-277V 50/60HZAC200-480V 50/60HZ
80W 100W 150W
9,855Lm 12,170Lm 18,715Lm
Class I Division 1 - T6Class I Division 2 - T4A Class II Division 2 - T4A
25° 60° 120°
R
in/mmUnits of Measure:
15kg / 33lbs
Weight
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
D13.5/3429.5/240
A7.6/193
B12.9/328
C
LEDs: 10 Years Driver: 7 Years
A
D
C
Pictured with yoke mounting option
Order Information
Accessories
YOKE: Yoke Mount STAN: Slip Fit Stanchion Mount Kit*SFCB: Safety Cable KitWG: Lens Wire guardSP1: 10KV Surge Protector
BLK-CS-11122019-V1.9
Block Series
BLK
Fixture
80
Wattage
80W100W150W
100-277
Voltage
100-277200-480
5000K
CCT
5000K4000K3000K**
120
Beam
120°
60°
25°
GREY
Color
Grey
PEND
Mounting
Pendant+
CLR
Lens
Clear
H1
Rating
H1-CID1H2-CID2
Photometrics
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
*Requires Yoke Mounting option
Pendant Mount
Yoke Mount with slip fit stanchion mount
**Special Order
Example: BLK-80-100-277-5000K-120-H1-CLR-GREY-PEND
+Pendant Mount standard, see above for other options
Class I Division 2, Groups A,B,C,D Class I Division 2, Groups A,B,C,D Class I Division 2, Groups A,B,C,D
Certifications and RatingsBlock-Mini Series H1
Dimensions
This Class I Division 1, superior designed, lightweight, compact, LED, area light is made for the most demanding environments and provides unmatched lighting performance with up to 200 lumens per watt. It is ideally suited for low mounting heights in offshore, gas, mining, particulate, chemical and other volatile environments.
Specifications
Class I Division 1, Groups B,C,D Class I Division 2, Groups A,B,C,D
Class II Division 1, Groups E,F,GClass III
CSA C22.2 No. 137-M1981; 25-1966CSA C22.2 No. 250.0-08; 250.13
UL 844 Hazardous LocationUL 1598A Marine Vessels
UL 1598 Wet Locations UL 8750 LED Safety
IP66 DLC (Contact Us)ABS (Contact Us)
™
®
Voltage/Frequency
Power Factor
THD
T-Code Ratings
Warranty
Construction
Lens Material
Hardware
Finish
Connection
IP / IK Rating
Color Rendering Index
L70
Surge Protection
>95% @120V
Marine Grade Cast Aluminum
Tempered Glass
316 Stainless Steel
Thermoset Powdercoat
3/4” NPT w/ 3’ 18/3 Cord or Leads
IP66 / IK08
Ra>70
4KvA (Standard) 10 KvA (option)
<20%
>50,000 Hours
T6 (C1D1) T4A (C1D2) T6 (C2D1)
LEDs: 10 Years Driver: 7 Years
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
AC 120-277V 50/60Hz AC 347-480V 50/60Hz*
Power 21W 40W 50W* 60W
Type II, III, V
CCT
Beam Angles
2700K 4000K 5000K
Operating Temperature -40°F to 149°F (-40°C to 65°C)^
Lumen Output++ 4,220Lm 6,500Lm 7,180Lm 8,515Lm
Shown with Pendant Mount
*347-480v only available in 50W * 50W only avalable in 347-480v ^-40°C to 64°C for 60W option++Lumen output represents Type 5 distribution and tempered Glass lens. output will change dependent on options
13.9 lbs/ 6.3 kg
Weight
5.1
in/ 1
30
mm
9.7 in/ 244 mm
8.3
in/ 2
11
mm
Photometrics
Order Information Block-Mini Series
BLM-H1-CS-11122019-V1.1Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
C0/180,112.5
C30/210,113.7
C60/240,112.9
C90/270,111.4
0
700
1400
2100
2800
3500
C0/180,134.6
C30/210,133.3
C60/240,98.3
C90/270,102.0
0
700
1400
2100
2800
3500
C0/180,102.1
C30/210,82.2
C60/240,73.0
C90/270,70.9
0
1000
2000
3000
4000
5000
Type II Type III Type V
5K-5000K4K-4000K3K-2700K**
T2-Type IIT3-Type IIIT5-110°
120-277 347-480*
Voltage
H1-CID1 CG - DG -
CORDLEAD
BLM
Fixture
5K
CCT
CORD
Wiring***
H1 CG PEND
Lens Mounting
T5
Beam
40
Wattage
120-277
YOKE - 304 Stainless Steel Yoke BracketSP1 - 10KvA Surge Protector for 120-277v***
SP2 - 10KvA Surge Protector for 347-480v***
Mounting Accessories
* 50W only with AC 347-480V **Special order ***Must be ordered with fixture +Pendant mount is standard * AC 347-480V only with 50W
Pendant Mount
Shown with yoke mount and diffused glass lens
Shown with Wire Guard Option
Rating
21W40W50W*60W
Pendant+ Clear glass Diffuse glass
Other Accessories
Wiring Requirements
WGG - Wire Guard for Glass lensSCFB - 316 Stainless Safety Cable
Example: BLM-40-120-277-5K-T5-H1-CLR-PEND-CORD
Contact Factory for Dimming Options
CORD - 3/4”npt with 3’ sjtow, 18/3 cord LEAD - 3’ leads
Linear Tuff Series
Dimensions
Bringing together energy efficiency, durability, and reliability, the Linear Tuff Series is designed to meet the most demanding harsh environments. Suitable for petrochemical facilities, drilling rigs, platforms, loading docks, mining, oil and gas refineries, tunnels, and other hazardous locations.
Specifications
Class I Division 1, Groups C,D Class I Division 2, Groups A,B,C,D
CSA C22.2 No. 250.0-08, 250.13-14 UL 844 Hazardous Location
UL 1598A Marine VesselsUL 1598 Wet Locations
UL 8750 LED Safety IP66
DLC (Contact Us)ABS (pending)
Voltage/Frequency
Power Factor
THD
Ambient Temperature
T-Code Ratings
Warranty
Construction
Lens Material
Hardware
Finish
Connection
Color Rendering Index
L70
Beam Angle
Power
Lumen Output
Surge Protection
AC100-277V 50/60HZAC200-480V 50/60HZ
>95% @120V
-40°F to 122°F (-40°C to 50°C)
Marine Grade Extruded Aluminum Housing and Die-cast Driver Box
Tempered Glass
Marine Grade Stainless Steel
Thermoset Powdercoat
3/4” NPT
Ra>70
110°
4KvA
40W 80W
4,805Lm 9,825Lm
Certifications and Ratings
™
®
Class I Division 1 - T6Class I Division 2 - T4A
4.3/1084.3/108
B40W80W
in/mmUnits of Measure:
Weight16.3lb/7.4kg 20.5lb/9.3kg
40W80W
>50,000 Hours
<20%; <10%
LEDs: 10 Years Driver: 7 Years
21.4/54445.3/1100
D
8.5/2158.5/215
A
Pictured with yoke mounting option
R
Red Sky Lighting LLC410 Main Street Racine, WI 53403 USA
[email protected] (833) 4REDSKY
D
C
BD
C 6.6/1686.6/168
Order Information
LNT 40 100-277 5000K CLR GREY PEND
Fixture Wattage Voltage CCT Lens Color Mounting
40W80W
100-277277-480
5000K4000K3000K*
ClearDiffuse
Grey YokePendant
Accessories
Linear Tuff Series
Photometrics
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
*Contact Us For availability **Must be ordered with yoke mount
Yoke Mount
Pendant Mount
Chain Mount
Pipe Clamp
YOKE: Yoke Mount Kit CHAIN: Stainless Steel Cable KitCLAMP: Pipe Clamp Kit** SFCB: Safety Cable KitSP1: 10kA Surge Protector UPCAP: Uplight limiting end caps
Linear Series
Dimensions
The Linear Series features a durable and ruggedized construction to endure environments where moisture, gases, dirt, corrosion, and vibration may be present. With it’s compact, low profile design, this fixture is perfect for low ceiling applications in walkways, overhangs, work and storage areas, and tunnels.
Specifications
Class I Division 2, Groups A,B,C,DClass II Division 1, Groups E,F,G
Class IIICSA C22.2 No. 137-M1981
CSA C22.2 No. 250.0-08, 250.13-14 UL 844 Hazardous Location
UL 1598A Marine VesselsUL 1598 Wet Locations
UL 8750 LED Safety DLC (Contact Us)
ABS (pending)IP66
Voltage/Frequency
Power Factor
THD
Ambient Temperature
Warranty
Construction
Lens Material
Hardware
Finish
Connection
Color Rendering Index
L70
Beam Angle
Power
Lumen Output
Surge Protection
AC100-277V 50/60HZAC200-480V 50/60HZ
>95% @120V
-40°F to 122°F (-40°C to 50°C)
T3C
Polycarbonate
Marine Grade Stainless Steel
Thermoset Powdercoat
3/4” NPT
Ra>70
110°
4KvA
<20%; <10%
40W 80W
5,965Lm 11,140Lm
Certifications and Ratings
Pictured with yoke mounting
LEDs: 10 Years Driver: 7 Years
T-Code Rating
Marine Grade Extruded Aluminum Housing and Die-cast Driver Box
A
5.0/1275.0/127
B7.6/1927.6/192
40W80W
in/mmUnits of Measure:
Weight11.0lb/5.0kg 15.2lb/6.9kg
40W80W
>50,000 Hours
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
23.7/60047.3/1200
C23.7/60047.3/1200
D6.6/1686.6/168
D
D
A
B
C
Order Information
LNR 40 100-277 5000K CLR GREY PEND
Fixture Wattage Voltage CCT Lens Color Mounting40W80W
100-277200-480
5000K4000K3000K**
ClearDiffuse
Grey PendantYoke
AccessoriesCHAIN: Chain Mounting Kit Yoke: Yoke Mount KitCLAMP: Pipe Clamp Kit*SFCB: Safety Cable KitSP1: 10kA Surge Protector
Linear Series
Photometrics
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
LNR-CS-11122019-V1.9 © 2019 Red Sky Lighting LLC All Rights Reserved
Yoke MountPendant Mount
Pipe Clamp Kit
Chain Mount
*Must be ordered with yoke mounting option **Contact Us
Example: LNR-40-100-277-5000K-CLR-GREY
Class I Division 2, Groups A,B,C,D Class I Division 2, Groups A,B,C,D Class I Division 2, Groups A,B,C,D
Certifications and RatingsBlock-Mini Series H2
Dimensions
This CID2 and CIID1 lightweight, compact, LED, area light packs a powerful punch by producing up to 200 lumens per watt and utilizing the industry favorite line of seven mounting options. It is ideally suited for low mounting heights in harsh and hazardous marine, power, and chemical environments.
Specifications
Class I Division 2, Groups A,B,C,D Class II Division 1, Groups E,F,G
Class III CSA C22.2 No. 137-M1981; 25-1966
CSA C22.2 No. 250.0-08; 250.13UL 844 Hazardous Location
UL 1598A Marine VesselsUL 1598 Wet Locations
UL 8750 LED SafetyIP66
DLC(Contact Us)
™
®
Voltage/Frequency
Power Factor
THD
T-Code Ratings
Warranty
Construction
Lens Material
Hardware
Finish
Connection
IP / IK Rating
Color Rendering Index
L70
Surge Protection
>95% @120V
Marine Grade Cast Aluminum
Tempered Glass / Polycarbonate
316 Stainless Steel
Thermoset Powdercoat
3/4” NPT w/ 3’ 18/3 Cord or Leads
IP66 / IK08 (TG) IK10 (PC)
Ra>70
<20%
>50,000 Hours
T4A (C1D2) T6 (C2D1)
LEDs: 10 Years Driver: 7 Years
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
AC120-277V 50/60Hz AC347-480V 50/60Hz*
Power 21W 40W 50W* 60W
Type II, III, V
CCT
Beam Angles
2700K 4000K 5000K
Operating Temperature -40°F to 149°F (-40°C to 65°C)^
Lumen Output++ 4200Lm 6500Lm 7180Lm 8515Lm
Shown with Polycarbonate Lens, 25° Wall Mount, and Wire Guard Shown with Tempered Glass Lens and Pendant
Polycarbonate
9.7 in/ 246 mm
5.6
in/ 1
42
mm
8.3 in/ 210 mm
5.1
in/ 1
42
mm
Tempered Glass
9.7 in/ 246 mm 8.3 in/ 210 mm
13.9 lbs/ 6.3kg
Weight
10.6 lbs/ 4.8kg
*347-480v only available in 50W *50W only available in 347-480v ^-40°C to 64°C for 60W option++Lumen output shown with Type 5 distribution and tempered Glass lens, output will change dependent on options
4KvA (Standard) 10 KvA (option)
Weight
Photometrics
Order Information Block-Mini Series
BLM-H2-CS-11122019-V1.1Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
C0/180,112.5
C30/210,113.7
C60/240,112.9
C90/270,111.4
0
700
1400
2100
2800
3500
C0/180,134.6
C30/210,133.3
C60/240,98.3
C90/270,102.0
0
700
1400
2100
2800
3500
C0/180,102.1
C30/210,82.2
C60/240,73.0
C90/270,70.9
0
1000
2000
3000
4000
5000
Type II Type III Type V
21W40W50W*60W
5K - 5000K4K - 4000K3K - 2700K**
CCTT2 - Type IIT3 - Type IIIT5 - 110°
PEND - 3/4” NPT Pendant+
YOKE - 304 Stainless Yoke BracketCEIL - Junction Box 3/4” NPT++
SN25 - Stanchion 25° - 1.5” NPT++
SN90 - Stanchion 90° - 1.5” NPT++
WL25 - Wall Mount 25° - 3/4” NPT++
WL90 - Wall Mount 90° - 3/4” NPT++
Mounting Options
120-277347-480*
H2 - CID2 Clear Glass Diffuse GlassDiffuse Poly- carbonate
CORD - 3’ SJTOW 18/3 CordLEAD - 3’ Leads0-10V Dimming standard on all options
Wiring***
BLM
Fixture
5K CORD
Wiring***
H2 CG PEND
Rating Lens Mounting
T5
Beam
21
Wattage
120-277
Voltage
ADPT - Mounting Adaptor for CEIL, SN25, SN90, WL25, & WL90++
WGG - Wire Guard for Glass lensWGP - Wire Guard for Polycarbonate LensSP1 - 10KvA Surge Protector for 120-277v***SP2 - 10KvA Surge Protector for 347-480v***SCFB - 316 Stainless Safety Cable
Mounting Accessories
SN25 SN90
YOKE
WL90
CEILPEND
Example: BLM-21-120-277-5K-T5-H2-CG-PEND-CORD
CG-
DG-
DP-
CORD LEAD
PEND+ YOKE CEIL SN25 SN90 WL25 WL90
*50W only with AC347-480V*AC347-480V only with 50W
**Special Order ***Must be ordered with fixture +Pendant mount is standard
Mounting adaptor (ADPT) will be supplied with all mounting accessories except pendant and yoke
++
WL25
0-10V Dimming standard on all options
Dimming
Certifications and RatingsRound Series
Dimensions
A compact, lightweight LED fixture that packs a powerful punch. This industry favorite has seven mounting options and produces 150 lumens per watt. Best utilized in harsh and hazardous environments for marine, power, and chemical industries.
Specifications
Class I Division 2, Groups A,B,C,D Class II Division 1, Groups E,F,G
Class II Division 2, Groups F,GClass III Division 1
CSA C22.2 No. 137-M1981; 25-1966CSA C22.2 No. 250.0-08; 250.13
UL 844 Hazardous LocationUL 1598A Marine Vessels
UL 1598 Wet Locations UL 8750 LED Safety
IP66DLC (Contact Us)
ABS (pending)
™
®
R
Voltage/Frequency
Power Factor
THD
Ambient Temperature
T-Code Ratings
Warranty
Construction
Lens Material
Hardware
Finish
Connection
Color Rendering Index
L70
Beam Angle
Power
Lumen Output
Surge Protection
>95% @120V
-40oF to 131oF (-40oC to 55oC)
Die-cast Aluminum
Tempered Glass
Marine Grade Stainless Steel
Thermoset Powdercoat
3/4” NPT
Ra>70
110o
4KvA
<20%
>50,000 Hours
AC200-480V 50/60HZ*AC100-277V 50/60HZ
40W* ; 45W 60W* ; 65W
6,760Lm 10,030Lm
Class I Division 2 - T4AClass II Division 1 - T5Class II Division 2 - T5
LEDs: 10 Years Driver: 7 Years
Weight
8.8lb / 4.0kg
Units of Measure: in/mm
A 10.3/262 6.1/155
B
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
Pictured with 25o Stanchion Mount
A
B
Photometrics
Order Information
RND
Fixture
45
Wattage45W65W40W*
60W*
100-277
Voltage100-277200-480*
5000K
CCT5000K4000K
CLR
LensClear
DiffuseGlobe
GREY
ColorGrey
PEND
MountingPendantYokeCeilingStan25Stan90Wall25Wall90
Round Series
Accessories
SFCB: Safety Cable KitWG: Flat Lens Wire GuardWGG: Globe Lens Wire guardSP1: 10kA Surge Protector
RND-CS-11122019-V1.94
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected] (833) 4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
*480V only available in 40W and 60W*40W and 60W only available in 480V
Pendant with Globe Lens
Yoke Mount with Globe Lens
Pendant
Stanchion 90 Stanchion 25
Wall 90 Wall 25
CeilingYoke
EXAMPLE: RND-45-100-277-5000K-CLR-GREY-PEND
Certifications and RatingsModular Series
Types
The Modular Series’ design features marine grade aluminum, polymers, and a rugged construction. Great for indoor, outdoor, commercial, harsh locations, and industrial applications. The expansive lumen range and multiple beam patterns makes it perfect for high bay, low bay, floodlighting, and general area lighting.
Specifications
UL 1598 Wet LocationsUL 8750 LED Safety
DLCIP67 Driver Enclosure
IP68 LED Modules
Voltage/Frequency
Power Factor
THD
Operating Temperature
Warranty
Construction
Lens Material
Hardware
Finish
Connection
Color Rendering Index
L70
Beam Angle
Power
Lumen Output
Surge Protection
>95% @ 230V
-40°F to 122°F (-40°C to 50°C)
LEDs: 10 Years Driver: 7 Years
Marine Grade Extruded Anodized Aluminum
Polycarbonate
Marine Grade Stainless Steel
Thermoset Powdercoat
18” cord
Ra>75
250, 60o, 90o, 120o*
4KvA
<20%
>50,000 Hours
AC100-277V 50/60HZAC200-480V 50/60HZ*
50W/100W/150W/200W/300W/400W
6000Lm ~ 48000Lm
50W 100W/150W
200W 300W
400W
6000Lm 12000Lm/18000Lm
24000Lm 36000Lm
48000Lm
R
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
*200-480v not available for the 50W and 100W**50W and 100W only available in 60o and 90o BEAM ANGLES
Dimensions
Order Information
MOD
Fixture
50
Wattage
50 W** 100 W**
150 W200 W300 W400 W
120-277
Voltage
120-277200-480*
5700K
CCT
5700K4000K3000K+
120
Beam Angle
120906025
**
**
ACCESSORIES
Chain: Eyebolt KitSFCB: Safety Cable KitJBOX: IP66 Wiring Junction Box
300W420mm16.5in
200W340mm13.4in
100/150W260mm10.2in
50W200mm7.9in
356
mm/1
4.1
in
400W580mm22.8in
356
mm/1
4.1
inModular Series
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
MOD-CS-11122019-V1.91 © 2019 Red Sky Lighting LLC All Rights Reserved
*200-480v not available for the 50W and 100W**50W and 100W only available in 60o and 90o
** 60o and 90o only available in 50W and 100W
+Special order
Example: MOD-50-120-277-5700K-120
Order Information High Bay Hot Series
Options
Accessories
ALR: Aluminum ReflectorTWIN: Dual Fixture mounting hardware
**Requires aluminum reflector accessory
Photometrics
HBH 150 100-277 5000K 110
Fixture Wattage Voltage CCT beam angle
100-2774000K5000K 110°
60°**150W
x2 150W fixtures shown withTwin Mount Kit and Aluminum Reflectors
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
© 2019 Red Sky Lighting LLC All Rights Reserved
347-480
Example:HBH-150-100-277-5000K-110
™
®
R
LNL-CS-11122019-V1.6 © 2019 Red Sky Lighting LLC All Rights Reserved
Certifications and Ratings
Dimensions Specifications
DLK2 Industrial Conveyor
in/mmUnits of Measure:
15.5/393
A
5.9kg / 13lbs
Weight
14.6/371
B6.7/169
C
A
B
C
Voltage/Frequency
Construction LM6 Aluminum Body Polycarbonate Cover
Lens Material Polycarbonate
Type 1 Type 3 Symmetrical
Hardware Marine Grade Stainless Steel
Connection M20x1.5 SS316 Cable Gland
Cool White: 5800-6900KWarm White: 2700-3000K Amber: 1800K
90-305VAC 47-63HZ127-431VDC 47-63HZ
Low Voltage: 23-27VDC
Power 62W
Operating Temperature -22°F to 122°F (-30°C to 50°C)
Lumen Output
Efficacy
6,400Lm
103Lm/W
Warranty Standard: 3 Years; Extended: 5 Years
L70
CRI
>50,000 Hours
>70 excluding Amber
CCT
Available Optics
UL 1598 Wet LocationUL 8750 LED Safety
CSA C22.2 No. 250.0-08CSA C22.2 No. 250.13-14
IP66IK09
DLK2 is designed to provide the most energy efficient way of illuminating industrial conveyors and walkways. The power consumption of less than 62W converts into a mere 1.5W per foot of conveyor line. The robust uni-body design is both lightweight and versatile with the flexibility to fit many industry standard spigot mount installations.
R
Power Factor >0.95 / AC230V
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
Order Information
Accessories
DSKY: Dark Sky Compliant Shield*
*Available with WWT LED option only
DLK2
Fixture
60
Wattage
60W
90-305
Voltage
90-305127-431
ELV 23-27
CWT
CCT
CWTWWTAMB
BW1
Optics
BW1 - Batwing Type 1BW3 - Batwing Type 3SY1 - Symmetrical
Photometrics
90
60
90
60
30 300
BW1 Batwing (Type 1 Optics)
cd/klm C0 ~ C180 C90 ~ C270
90
60
90
60
30 300
BW3 Batwing (Type 3 Optics)
cd/klm C0 ~ C180 C90 ~ C270
90
60
90
60
30 300cd/klm C0 ~ C180 C90 ~ C270
SY1
DLK2 Industrial Conveyor
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
DLK2-CS-11122019-V1.3 © 2019 Red Sky Lighting LLC All Rights Reserved
Shown with Dark Sky Compliant Shield*
Example: DLK2-60-90-305-CWT-BW1
Certifications and Ratings
Dimensions Specifications
CP22-Superbeam
4.5kg / 9.9lbs
Weight
Marine / Wet LocationIP66IK09
the CP22-Superbeam is built for the harshest environments and to endure continuous exposure to vibration and elements. Originally designed for use on railways, this marine grade navigation light is an ideal luminaire for long distance, narrow beam angle illumination with a peak intensity of >200,000 Candella.
Voltage/Frequency
Construction LM6 Aluminum Body Toughened Glass Lens
Optic Material PMMA
Narrow
Hardware Marine Grade Stainless Steel
Connection UL2095, 16 AWG x 2C Braid PVC
5900-6500K
DC12-30VAC100-277V or 200-480V*
Power 60W
Operating Temperature -22°F to 122°F (-20°C to +50°C)
Peak Intensity 214,200 Cd
Warranty Standard: 3 Years; Extended: 5 Years
L70
CRI
>50,000 Hours
>70
CCT
Available Optics
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
232mm
108mm265mm
211mm
213mm
Ø12mm
226mm
108mm
160mm
50mm 50mm
Mounting Bracket Dimensions
*Contact us for more information
Lumen Output 4,623 Lm
Order Information
Photometrics
CP22-Superbeam
Red Sky Lighting LLC410 Main Street Racine, WI, 53403 USA
[email protected](833)-4REDSKY
CP22-CS-11122019-V1.4 © 2019 Red Sky Lighting LLC All Rights Reserved
CP22
Fixture
60
Wattage
60W
12-30
Voltage*
12-30Vdc
MPB
Mounting
MPB - Mobile BracketFPB - Fixed Bracket
24VDC INWhite (Positive)Black (Negativ e)
Steel WireBraide d Cable
+ –
ELVExtra Low Voltage
*Contact us for remote power supply information 100-277V or 200-480V