Redefining NIPT as we know it. The VeriSeq NIPT Solution. One comprehensive workflow. Rachel Felt reassurance with NIPT

Upload: dinhtu

Post on 11-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Redefi ning NIPT as we know it.The VeriSeq™ NIPT Solution. One comprehensive workfl ow.

Rachel Felt reassurance with NIPT

Page 2: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Noninvasive prenatal testing (NIPT) has been proven superior to traditional screening methods for

detecting common fetal aneuploidies. By increasing specifi city (ie, reducing false positive rates),1,2

NIPT helps limit invasive procedures—and therefore, the risk of miscarriage—when used as a

primary screen.

Illumina sequencing is the foundational technology powering NIPT. In fact, it has been used in more

than 99% of published NIPT samples to date.3 As your trusted NIPT partner, and the company

that brought you the Verifi ® Prenatal Test, we are proud to announce the next step in the evolution

of NIPT testing.

Taking NIPT to a new levelA revolutionary in-lab method from Illumina Excellent outcomes. One comprehensive workflow.

Introducing the VeriSeq NIPT Solution—an automated and validated workfl ow including

CE-IVD–marked sample prep and assay software. The solution provides results for up to

96 samples in just over 24 hours.

From sample prep to sequencing to analysis, the VeriSeq NIPT Solution streamlines your

process as one comprehensive workfl ow.

VeriSeq NIPT Workfl ow ManagerSpecialized software for automated preparation of samples

VeriSeq NIPT Microlab STARUnique liquid handling robot, optimized for the VeriSeq NIPT Solution workfl ow

*The sequencer depicted here is for illustrative purposes only and is not CE-IVD marked.

VeriSeq NIPT Sample Prep KitsSpecially designed kits for full preparation of 48 or 96 samples

VeriSeq Onsite ServerSecure on-site server with revolutionary assay software for NIPT analysis and reporting

For in Vitro Diagnostic Use. Not available in all regions and countries.

The Verifi ® Prenatal Test was developed by, and its performance characteristics were determined by Verinata Health, Inc. (VHI) a wholly owned subsidiary of Illumina, Inc. The VHI laboratory is CAP-accredited and certifi ed under the Clinical Laboratory Improvement Amendments (CLIA) as qualifi ed to perform high complexity clinical laboratory testing. It has not been cleared or approved by the U.S. Food and Drug Administration.

Page 3: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Novel paired-end sequencingNo PCR required

The VeriSeq NIPT Solution minimizes hands-on time and maximizes simplicity. An automated, PCR-free

workfl ow means batches of 96 or 48 samples can go from sample to report in just over 24 hours with

minimal hands-on time. No post-PCR area is required, and only one automated liquid handling system

is needed. These features make the VeriSeq NIPT Solution easy to implement and easy to use in any

clinical lab.

The VeriSeq NIPT Solution leverages our paired-end sequencing NIPT technology, resulting in a truly

revolutionary analysis. During paired-end sequencing, both ends of a DNA fragment are analyzed,

allowing for the size determination of each cell-free DNA (cfDNA) fragment in the sample (Figure 1).

Studies have shown that in a maternal sample, shorter cfDNA fragments tend to be fetal in origin

while longer fragments tend to be maternal (Figure 2).4,5

Using paired-end sequencing, the VeriSeq NIPT Solution can improve the signal-to-noise ratio by

selecting shorter fragments and make highly accurate calls using as little as one-third the read depth

of other sequencing assays. This saves time and resources compared to single-read protocols,

producing NIPT results quickly and cost effectively.

For in Vitro Diagnostic Use. Not available in all regions and countries.

Page 4: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Insert size

Paired-End Sequencing: Fragment Size

50 350250 300150 200100 400

Freq

uenc

y

0.005

0.010

0.015

0.020

0

Fetal (chromosome Y)

Maternal + fetal(robust autosomes)

Figure 2: Distribution of cfDNA Fragment Size Based on Maternal or Fetal Origin. The orange trace represents fetal cfDNA fragments while the white trace represents maternal. Fetal cfDNA is comprised of proportionally shorter fragments.3

Figure 1: Single-Ended Read vs Paired-End Read. Paired-end reads help determine fragment size to further distinguish the signal-to-noise ratio.3

ATTTCCGCGATCTTCCCGTTCGACTGCAGACCTTCAGCGCGCATATATCGCTAGCATACCGTTATACCGCTAGAAG

ATTTCCGCGATCTTCCCGTTCGACTGCAGACCTTCAGCGCGCATATATCGCTAGCATACCGTTATACCGCTAGAAG GAAGTCGCG

Single-Ended Read

Paired-End Read

Human genome

Human genome

Fragment length

Second read anchors the fragment and limits misalignment

Page 5: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Samples that fail NIPT and provide no result drive a need for further clinical follow-up and additional

testing. The International Society for Prenatal Diagnosis (ISPD) states that after a NIPT failure, alternative

testing versus repeat NIPT may be considered.6

The VeriSeq NIPT Solution utilizes a simplifi ed workfl ow and a new analysis method aimed toward

minimizing failure rate and rescuing low fetal fraction samples, thus providing results on a larger proportion

of processed samples. In fact, the Veriseq NIPT Solution showed a 0.68% overall sample failure rate in a

3107 sample clinical study. Other tests may have higher failure rates, and failed samples require additional

followup—which may be an invasive procedure. The VeriSeq NIPT Solution aims to greatly reduce the

chances of these procedures due to low false positive rate and low sample failure rate.

Provide results on more samples Assay failures may lead to invasive procedures

References1. Bianchi DW, Parker RL, Wentworth J, et al. DNA sequencing versus standard prenatal aneuploidy screening (CARE study). N Engl J Med. 2014;370:799-808. 2. Norton ME, Jacobsson B, Swamy GK, et al. Cell-free DNA analysis for noninvasive examination of trisomy. N Engl J Med. 2015;372(17):1589-1597.3. Data calculations on fi le. Illumina, Inc., 2015.4. Internal Illumina data on fi le. 5. Lo YN, Chan KC, Sun H, et al. Maternal plasma DNA sequencing reveals the genome-wide genetic and mutational profi le of the fetus. Sci Transl Med. 2010;61(2):61-91.

6. Benn P, Borrell A, Chiu R, et al. Position statement from the Chromosome Abnormality Screening Committee on behalf of the board of the International Society for

Prenatal Diagnosis. Prenat Diagn. 2015;35(8):725-734.

Figure 3: Distribution of Fetal Fraction of More Than 2000 NIPT Samples.3 If the system utilized fetal fraction exclusively to exclude samples,a signifi cant proportion would not be analyzed. Because the VeriSeq NIPT Solution is optimized to handle samples at the lower end of the fetal fraction range (highlighted in orange), results will be provided to a larger proportion of samples than if these samples were excluded.

0.10 0.15 0.20 0.25 0.30 0.350.050.00

2

0

4

6

8

Fetal fraction

Distribution of Fetal Fraction4

Den

sity

10

Res

cued

sam

ple

s

For in Vitro Diagnostic Use. Not available in all regions and countries.

Page 6: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Empowering breakthroughs in genetic screeningYour partner in reproductive genomics

A trusted leader in genomic solutions, Illumina offers a comprehensive reproductive and genetic health

portfolio. With breakthrough genetic screening technology, we are well equipped to serve the needs

of clinical laboratories, health care professionals, and patients. Together, we can empower informed

reproductive choices and improve the future of genetic disease detection.

Page 7: Redefi ning NIPT as we know it. - Illumina | … · Redefi ning NIPT as we know it. ... 2. Norton ME, Jacobsson B, ... solutions to the basic and translational research communities

Illumina • 1.800.809.4566 toll-free (US) • +1.858.202.4566 tel • [email protected] • www.illumina.com

For in Vitro Diagnostic Use. Not available in all regions and countries.

© 2017 Illumina, Inc. All rights reserved. Pub. No. 1570-2017-012 Document # 1000000032102 v00

A global genomics leader, Illumina provides comprehensive next-generation sequencing workfl ow

solutions to the basic and translational research communities. Illumina technology is responsible for

generating more than 90% of the world’s sequencing data.* Through collaborative innovation, Illumina

is fueling groundbreaking advancements in the fi elds of oncology, reproductive health, genetic disease,

microbiology, agriculture, and forensic science.

*Data calculations on fi le. Illumina, Inc., 2015.

Industry-leadingsolutions Illumina genomic solutions empower labs and researchers across the

globe to fi nd the answers they seek.

When you join the Illumina community, you become part of a dynamic

scientifi c movement that includes thousands of industry thought leaders.

Throughout the year, we host user group meetings, symposia, consortia,

online forums, and other initiatives—all designed to bring the best minds

together to share ideas and advance science.

In addition to on-site training, ongoing support, and phone consults,

we offer webinars and courses at various Illumina locations. We’re here

with all the resources you need to accelerate progress.

Contact your Illumina sales representative to fi nd out how to bring the VeriSeq NIPT Solution to your lab.

www.illumina.com/VeriSeqNIPT

The VeriSeq NIPT Solution is an in vitro diagnostic test intended for use as a sequencing-based screening test for the detection of fetal aneuploidies from maternal peripheral whole blood samples in pregnant women of at least 10 weeks gestation. The VeriSeq NIPT Solution provides information regarding aneuploidy status for chromosomes 21, 18, 13, X, and Y. This product must not be used as the sole basis for diagnosis or other pregnancy management decisions.

Noninvasive prenatal testing (NIPT) based on cell-free DNA analysis from maternal blood is a screening test; it is not diagnostic. Test results must not be used as the sole basis for diagnosis. Further confi rmatory testing is necessary prior to making any irreversible pregnancy decision.