reduced-wiring system serial transmission system€¦ · mitsubishi electric corp. sharp corp. fuji...

12
Reduced-wiring System Serial Transmission System SI supported protocols chart Page 1 to 4 SI valve compatibility chart Page 5 to 10 Glossary of terms Page 5 to 9 INDEX Selection guide for serial interface units showing compatibility with valve series and supported protocols NCAT.E02-1A

Upload: others

Post on 29-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

Reduced-wiring System

Serial Transmission System

SI supported protocols chart Page 1 to 4

SI valve compatibility chart Page 5 to 10

Glossary of terms Page 5 to 9

INDEX

Selection guide for serial interface units showing compatibility with valve series and supported protocols

NCAT.E02-1A

Page 2: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

Integ

rated

co

ntroll

er un

der

deve

lopme

ntEX120

Integrated type, for output

16-point output 16-point output

Common Common Separated

CE

EX120EX121EX122

EX123 EX124 EX126EX140 EX180

16-point output

CE, UL/CSA

32-point output

Separated Separated

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

MELSECNET/MINI-S3

SI supported protocols chart

Product part no.

Family model no.

No. of input points (Max.)

Bas

ic fu

nctio

ns

International standards

Power supply for communications and valves

No. of output points (Max.)

DeviceNet

JEMA Net (OPCN-1)

PROFIBUS-DP

CC-Link

INTERBUS

Actuator Sensor interface (AS-i, ASI)

CAN Open

Lon Works

Smart Distributed System (SDS)

OMRON Corp.CompoBus/S

SYSBUS

Satellite I/O

T Link Mini

MEWNET-F

Remote I/O

NKE Corp.

S-LINK

Reduced-wiring system

Reduced-wiring H system

Mitsubishi Electric Corp.

SHARP Corp.

Fuji Electric Co., Ltd.Matsushita Electric Works, Ltd.

Rockwell Automation, Inc.

SUNX Corp.

SAVENET(ECONO-BUS, HLS)

DeviceNet safety

PROFI safety

INTERBUS safety

AS-i safety

INTERBUS Rugged line

ControlNet

Lightbus

IP-LINK

EtherNet

EtherNet/IP

PROFInet

Modbus TCP

Ether CAT

SMC LOGIC

WorldFIP

Rockwell Automation, Inc.

SMC Corp.

DeviceLogix

Com

plie

s w

ith th

e op

en n

etw

ork

(Offe

red

by s

ever

al m

anuf

actu

rers

)C

ompl

ies

with

a re

spec

tive

PLC

man

ufac

ture

rCo

mplie

s with

seve

ral

PLC

manu

factur

ersPr

otoc

ol u

nder

de

velo

pmen

tPl

anne

d to

be

addr

esse

d in

the

futu

re

O.N. Electronic Co., Ltd.

1

Page 3: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

EX500 EX510Separate type (Gateway, 4-branch)

CE, UL/CSA

64-point output (16-point x 4-branch)

64-point input (16-point x 4-branch)

EX240 EX250

CE CE, UL/CSA

Integrated type, for input/output

32-point input

32-point output

Separated SeparatedSeparated Common/Separated Note 1)

EX600Under development

Separated (planned)

Under development

CE, UL/CSA (planned)

MELSECNET/MINI-S3

DeviceNet safety

PROFI safety

INTERBUS safety

AS-i safety

EtherNet

EtherNet/IP

PROFInet

Modbus TCP

Ether CAT

SMC LOGIC

WorldFIP

DeviceLogix

Product part no.

Family model no.

No. of input points (Max.)

Bas

ic fu

nctio

ns

International standards

Power supply for communications and valves

No. of output points (Max.)

DeviceNet

JEMA Net (OPCN-1)

PROFIBUS-DP

CC-Link

INTERBUS

Actuator Sensor interface (AS-i, ASI)

CAN Open

Lon Works

Smart Distributed System (SDS)

OMRON Corp.CompoBus/S

SYSBUS

Satellite I/O

T Link Mini

MEWNET-F

Remote I/O

NKE Corp.

S-LINK

Reduced-wiring system

Reduced-wiring H system

Mitsubishi Electric Corp.

SHARP Corp.

Fuji Electric Co., Ltd.Matsushita Electric Works, Ltd.

Rockwell Automation, Inc.

SUNX Corp.

SAVENET(ECONO-BUS, HLS)

INTERBUS Rugged line

ControlNet

Lightbus

IP-LINK

Rockwell Automation, Inc.

SMC Corp.

Com

plie

s w

ith th

e op

en n

etw

ork

(Offe

red

by s

ever

al m

anuf

actu

rers

)C

ompl

ies

with

a re

spec

tive

PLC

man

ufac

ture

rCo

mplie

s with

seve

ral

PLC

manu

factur

ersPr

otoc

ol u

nder

de

velo

pmen

tPl

anne

d to

be

addr

esse

d in

the

futu

re

O.N. Electronic Co., Ltd.

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

Note 1) Common power supply is only available with ASI.

512-point output (planned)

512-point input (planned)

Integ

rated

co

ntroll

er un

der

deve

lopme

nt

2

Page 4: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

Special products for specific customersEX150 EX160 NP420 EX230 EX16 (temporary name)

16-point output

Separated Separated Separated Separated

16-point output 32-point output 16-point output 16-point output (planned)

32-point input 5-point input

CE UL/CSA CE, UL/CSA (planned)

Common (planned)

Planned

Planned

MELSECNET/MINI-S3

Product part no.

Family model no.

No. of input points (Max.)

Bas

ic fu

nctio

ns

International standards

Power supply for communications and valves

No. of output points (Max.)

DeviceNet

JEMA Net (OPCN-1)

PROFIBUS-DP

CC-Link

INTERBUS

Actuator Sensor interface (AS-i, ASI)

CAN Open

Lon Works

Smart Distributed System (SDS)

OMRON Corp.CompoBus/S

SYSBUS

Satellite I/O

T Link Mini

MEWNET-F

Remote I/O

NKE Corp.

S-LINK

Reduced-wiring system

Reduced-wiring H system

Mitsubishi Electric Corp.

SHARP Corp.

Fuji Electric Co., Ltd.Matsushita Electric Works, Ltd.

Rockwell Automation, Inc.

SUNX Corp.

SAVENET(ECONO-BUS, HLS)

DeviceNet safety

PROFI safety

INTERBUS safety

AS-i safety

INTERBUS Rugged line

ControlNet

Lightbus

IP-LINK

EtherNet

EtherNet/IP

PROFInet

Modbus TCP

Ether CAT

SMC LOGIC

WorldFIP

DeviceLogix

Com

plie

s w

ith th

e op

en n

etw

ork

(Offe

red

by s

ever

al m

anuf

actu

rers

)C

ompl

ies

with

a re

spec

tive

PLC

man

ufac

ture

rCo

mplie

s with

seve

ral

PLC

manu

factur

ersPr

otoc

ol u

nder

de

velo

pmen

tPl

anne

d to

be

addr

esse

d in

the

futu

re

O.N. Electronic Co., Ltd.

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

Rockwell Automation, Inc.

SMC Corp.

3

Integ

rated

co

ntroll

er un

der

deve

lopme

nt

Page 5: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

DeviceNet

JEMA Net (OPCN-1)

PROFIBUS-DP

CC-Link

INTERBUS

Actuator Sensor interface (AS-i, ASI)

CAN Open

Lon Works

Smart Distributed System (SDS)

MELSECNET/MINI-S3CompoBus/S

SYSBUS

Satellite I/O

T Link Mini

MEWNET-F

Remote I/O

S-LINK

Reduced-wiring system

Reduced-wiring H system

SAVENET (ECONO-BUS, HLS)

DeviceNet safety

PROFI safety

INTERBUS safety

AS-i safety

INTERBUS Rugged line

ControlNet

Lightbus

IP-LINK

EtherNet/IP

PROFInet

Modbus TCP

Ether CAT

SMC LOGIC

WorldFIP

DeviceLogix

Name of protocol Features of protocol Communications speed (bps)

125k, 250k, 500k

125k, 250k, 500k, 1M

9.6k, 19.2k, 93.75k, 187.5k, 0.5M, 1.5M, 12M

156k, 625k, 2.5M, 5M, 10M

500k, 2.0M

125k

125k, 250k, 500k

9.6k, 19.2k, 93.75k, 187.5k, 0.5M, 1.5M, 12M

500k, 2.0M

125k

31.25k, 1M, 2.5M, 5M

100M

78k

10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M

125k, 250k, 500k, 1M

1.5M

750k

187.5k

500k

28.5k

28.5k

29.4k

3M, 6M

10M, 100M

10M, 100M

10M, 100M

500k, 2M

5M

2M

2.5M

57.6k, 115.2k, 230.4k

250k, 500k

172.8k, 345.6k

Features of Protocol and its Overview

Prevalent mainly in the U.S.A. Widely adopted in the semiconductor and the automobile industry.Prevalent mainly in the EU area. High speed data transmission. Widely adopted in the general industry.Prevalent mainly in Japan. High speed data transmission. Widely adopted in the general industry.Standardized by the Japan Electrical Manufacturers' Association (JEMA). Adopted bythe automobile industry in Japan.

Widely adopted in the automobile industry, mainly in the EU area.

Open network prevalent mainly in the EU area (France).

Widely adopted in the automobile industry, mainly in the EU area.

Mainly in the food industry. Allocated in a deconcentrated way with a small number of points.

Mainly in the North American area. Adopted in the fields of building automation and industry equipment.

Application of the CAN technology. Adopted in the semiconductor industry.

Mainly adopted in the U.S.A. as a higher ranked protocol than DeviceNet. (Between PLC and PLC)

Ethernet technology. Transmits the 1000-point I/O data in 30 µs.

Proprietary network (local network) developed by Japanese PLC manufacturers.

Proprietary network (local network) developed by Japanese PLC manufacturers.

Adoption of the optical communications technology. Mainly in the EU area, adopted in the automobile industry.

Besides common I/O data communications, additional data such as self-diagnosis information, etc. are included in order to enhance the reliability of the communications.

Integration of compact PLC function. Considered as a systematic product toward the small-sized production line.

Using the common TCP/IP technology among the Ethernet communications technologies. Creates a communications link between high end systems using Ethernet and I/O equipment using DeviceNet,PROFIBUS or Modbus.

Protocol means the serial data is sent and/or received in accordance with a named specification.

The communication speed refers to the volume of data communicated per second and is described in bps or bits per second.1 kbps means that 1,000 bits per second can be transmitted and 1 Mbps means 1,000,000 bits per second.For example, assuming that 100 bits is transmitted at 1 kbs, its transmission time will be 0.1 seconds.If transmitted at 1 Mbps, it is possible to transfer in 0.0001 seconds.

4

Page 6: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

5

Serial transmission system and SI unitPLC PLC

<Conventional method> <Serial transmission method>

Manifoldsolenoidvalves

Multiplewires

Serialtransmission

line

SI manifoldsolenoidvalves

Power supplySI unit

Glossary of terms

EX120

Integrated type, for output

IP20 IP65

Direct

Flat ribbon cable

DIN rail Direct

Plug-in Plug-in Plug-lead Plug-in

EX120 EX121 EX122 EX123 EX124 EX126

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industryUsable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Automobile industry, semiconductor industry, etc.

SI valve compatibility chart

1000

2000

3000

3000

3000

4000

5000

50007000

3000

5000

3000

5000

7000

7000

3000

5000

7000

9000

SV

SX

SY

SYJ

2000

3000

3000SZ

SJ

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Bar stock type

Bar stock type

Stacking type

App

licab

le v

alve

s

A serial transmission system can control multiple solenoid valves by using only the communication line from the PLC’s communication module (master module) or it can read the signal from the various sensors. This system can also be called a “Fieldbus system”.

Wiring the coil of each solenoid valve, one by one, to the output unit on the PLC is called “Parallel wiring”. Each valve in use needs to be connected. Therefore, wiring in accordance with the number of solenoid valves or sensors in use is required.

A SI unit is a device which can control the solenoid valve through serial communication.

Page 7: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

EX500 EX510EX140 EX180 EX240 EX250

IP20 IP20

Integrated type, for output

Plug-in Plug-in Plug-in Plug-lead,Flat ribbon cable

DirectDirect Direct/DIN railDirect/DIN rail

IP65 IP65IP67

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industry

Integrated type, for input/output Separate type (Gateway, 4-branch)

Usable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Semiconductor industry, etc.

Usable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

1000

2000

3000

3000

3000

4000

5000

50007000

3000

5000

3000

5000

7000

7000

3000

5000

7000

9000

SV

SX

SY

SYJ

2000

3000

3000 SZ

SJ

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Bar stock type

Bar stock type

Stacking type

Number of outputs, Number of inputsOutput compatibility, Input/Output compatibility Protocol and Open networkGlossary of terms

App

licab

le v

alve

s

Number of outputs is the number of solenoid or output devices that can be controlled.

Number of inputs is the number of various sensors such as an auto switch, pressure switch, etc. that can be connected.

Output refers to the control device for turning on/off the solenoid coil.

Input/Output refers to the ability for ON-OFF control (output) of a solenoid valve, as well as the reading (input) of a sensor signal, such as from an auto switch or pressure switch.

Protocol means the serial data is sent and/or received in accordance with a named specification.

Open network means a standard that has been made public and is widely accepted.

6

Page 8: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

1000

2000

3000

1000

2000

4000

1000

2000

4000

5000

VQC

VQ

VQZ

1000

2000SQ

VSR

VSS

8-6

8-8

8-10

8-6

8-8

8-10

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Stacking type

0700S

Bar stock type

0700

5000

Stacking type

App

licab

le v

alve

sEX120

Integrated type, for output

IP20 IP65

Direct

Flat ribbon cable

DIN rail Direct

Plug-in Plug-in Plug-lead Plug-in

EX120 EX121 EX122 EX123 EX124 EX126

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industryUsable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Automobile industry, semiconductor industry, etc.

UL/CSA standards CE markingGlossary of terms

UL and CSA standards are applied in North America where it (U.S.A. and Canada) symbolizes the safety of electric products, and are defined to mainly prevent danger from an electrical shock or fire, resulting from defective electrical products.The power supply of the SI unit is 24 V DC, which does not meet the voltage requirement for the electrical shock category. However, measures against a fire hazzard have been taken. Some SI units are UL/CSA certified.

CE marked products or equipment that are exported from Japan to countries that are EU members, must confirm to the EC directives. SMC products are subject to either or both the low power voltage directive (regarding electrical safety) or the EMC directive (regarding solenoid conformity).The operating voltage of the SI unit is 24 V DC, therefore it is not subjected to the low voltage directive (50 to 1000 V AC or 75 to 1500 V DC). The SI unit undergoes EMC testing by a third party and bears the CE marking (self-declaration).Since our product is ultimately a component which is integrated into the equipment of a user, the user must verify that the equipment or facility confirms to the EC directive.

7

Page 9: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

EX500 EX510EX140 EX180 EX240 EX250

IP20 IP20

Integrated type, for output

Plug-in Plug-in Plug-in Plug-lead,Flat ribbon cable

DirectDirect Direct/DIN railDirect/DIN rail

IP65 IP65IP67

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industry

Integrated type, for input/output Separate type (Gateway, 4-branch)

Usable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Automobile industry, semiconductor industry, etc.

Usable in locations where it may be exposed to water or dust.Semiconductor industry, etc.

Usable in locations where it is not exposed to water or dust.Automobile industry, semiconductor industry, etc.

1000

2000

3000

1000

2000

4000

1000

2000

4000

5000

VQC

VQ

VQZ

1000

2000SQ

VSR

VSS

8-6

8-8

8-10

8-6

8-8

8-10

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Stacking type

0700S

Bar stock type

0700

5000

Stacking type

App

licab

le v

alve

s

Enclosure Valve interfaceGlossary of terms

The enclosure is rated using the IP (International Protection) standard (IEC60529) which focuses on protection against dust or water.

IP20: Protection against fingers entering the enclosure but not specifically against water.

IP65: Protection against dust entering the enclosure and not greatly affected by jets of water from all directions.

IP67: Protection against dust entering the enclosure and immersion in water at a specific pressure and time.

The valve interface is the connection between the SI unit and the solenoid valve's manifold.

Plug-in: The connector on the SI unit and the solenoid valve’s manifold directly plug into each other.

Plug lead: The SI unit and the solenoid coil are connected with wires having a connector.

Flat ribbon cable: The SI unit and solenoid valve’s manifold are connected together with a flat ribbon cable having a MIL connector.

8

Page 10: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

EX150EX600 EX160 NP420 EX230Under development

Under development

IP67 (planned) IP67 IP20 IP20 IP65 / NEMA4

Special products for specific customers

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in (planned)

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industry

Usable in locations where it may be exposed to water or dust.General machinery industry

Usable in locations where it is not exposed to water or dust.Semiconductor industry

Usable in locations where it may be exposed to water or dust.Semiconductor industry

Usable in locations where it may be exposed to water or dust.Automobile industry

1000

2000

3000

3000

3000

4000

5000

50007000

3000

5000

3000

5000

7000

7000

3000

5000

7000

9000

SV

SX

SY

SYJ

2000

3000

3000SZ

SJ

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Bar stock type

Bar stock type

Stacking type

The centralized type means the SI unit and solenoid valve’s manifold are integrated. An SI unit is necessary for every protocol.

The de-centralized type refers to the GW (Gateway) method. From the Gateway, the solenoid valve’s manifold and the input devices can be located remotely. The replacement of the Gateway enables changing between the various protocols.

Centralized and De-centralized type (Gateway method) Bar stock type and Stacking typeGlossary of terms

The bar stock type consists of a manifold base made of Aluminum with a fixed number of manifold stations.The stacking type consists of a cassette base manifold or a tie-rod base manifold both of which allow increasing/decreasing of the number of stations easily.

App

licab

le v

alve

s

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

9

Page 11: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

: Available (However, delivery will be approximately 6 months from the time the development is started.)

: Made to Order : Standard : Under development/planned

: Available after the standard products are launched. (However, delivery will be approximately 6 months from the time the development is started.)

: Not available or available with other model(s)

Product part no.

Family model no.

Enclosure

Mounting

Valve interface

Bas

ic fu

nctio

ns

Operating environment and industry

EX150EX600 EX160 NP420 EX230Under development

Under development

IP67 (planned) IP67 IP20 IP20 IP65 / NEMA4

Special products for specific customers

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in

Direct

Plug-in (planned)

Usable in locations where it may be exposed to water or dust.General machinery industry

Usable in locations where it is not exposed to water or dust.Semiconductor industry

Usable in locations where it may be exposed to water or dust.Semiconductor industry

Usable in locations where it may be exposed to water or dust.Automobile industry

1000

2000

3000

1000

2000

4000

1000

2000

4000

5000

VQC

VQ

VQZ

1000

2000SQ

VSR

VSS

8-6

8-8

8-10

8-6

8-8

8-10

Stacking type

Stacking type

Stacking type

Stacking type

Bar stock type

Stacking type

0700S

Bar stock type

0700

5000

Stacking type

App

licab

le v

alve

s

10

Page 12: Reduced-wiring System Serial Transmission System€¦ · Mitsubishi Electric Corp. SHARP Corp. Fuji Electric Co., Ltd. Matsushita Electric Works, Ltd. Rockwell Automation, Inc. SUNX

1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPANTel: 03-3502-2740 Fax: 03-3508-2480URL http://www.smcworld.com© 2005 SMC Corporation All Rights Reserved

1st printing JT printing JT 150KS Printed in Japan.D-KS

This pamphlet is printed on recycled paper with concern for the global environment.

Note: Please acknowledge that this content might change without a previous notice beforehand.Each company might be using the name of the commodity of this manual publishing respectively as a trademark.