Reducing NOx Emissions to Below 0.15 lb/106 Btu on a 600 MW Utility Boiler with
Combustion Control Only
by
Craig A. PentersonManager, Fuel Equipment Design
RILEY POWER INC.a Babcock Power Inc. company
Kenneth R. Hules, Sc.D.Senior Principal Engineer, CFD
RILEY POWER INC.a Babcock Power Inc. company
Presented at DOE/EPRI/EPA/A&WMA Combined Power Plant
Air Pollutant Control “Mega” SymposiumMay 19-22, 2003Washington, DC
Technical Publ icat ion
T-183
-
Text1: 0183