refer to drawing so4 relbia road - · pdf fileproposed new shed by others approximate natural...
TRANSCRIPT
5
0
0
-
2
5
0
0
-
3
0
0
0
-
3
5
0
0
-
2
0
0
0
r
t
h
2
0
0
0
-
1
5
0
0
2
5
0
0
1
0
0
0
0
-
5
0
0
-
1
0
0
0
1
5
0
0
3
4
°
5
9
'
3
5
"
9
1
4
4
0
2
1
4
°
5
9
'
3
5
"
9
1
4
4
0
3
0
0
0
E
W
S
1
0
4
°
3
1
' 4
0
"
4
7
2
4
4
1
0
4
°
3
1
' 4
0
"
4
7
2
4
4
R
E
LB
IA
R
O
A
D
2
0
0
0
STORMWATER OVERFLOW TRENCH
REFER TO DRAWING SO4
1
5
0
0
PROPOSED SHED BY OTHERS
r
t
h
E
W
S
STORMWATER TANK BY OTHERS
BATTER BANK
SITE PLAN
SCALE 1:500
2
1
0
0
0
7
0
0
0
SCALE: AS NOTED SHEET SIZE: A3 DWGs IN SET: 7
DRAWN BY: DRP
DESIGN CHK: RJJ
DESIGN BY: MRP
DRAFT CHK: -
DATE: 26.10.17PROJECT No: 17265 DWG No: S01 REV: 0
TITLE:
OVER ALL SITE PLAN
CLIENT:
PROJECT:
ADDRESS:
APPROVED: R.JESSON ACRED. No: CC5848I
STATUS:
CONSTRUCTION
DO NOT SCALE - IF IN DOUBT, ASK
THIS DOCUMENT MAY ONLY BE USED FOR THE PURPOSE FOR WHICH IT
WAS PREPARED. © RARE INNOVATION PTY LTD. ABN 51 619 598 257
REV:
0 ISSUED FOR CONSTRUCTION DRP
DATE:
26-10-17
DESCRIPTION: BY:
MATT FRASER
255 RELBIA RD, RELBIA
RETAINING WALL DESIGN
255 RELBIA RD, RELBIA
Version: 1, Version Date: 01/11/2017Document Set ID: 3661950Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623
5
0
0
-
2
0
0
0
-
1
5
0
0
1
0
0
0
0
-
5
0
0
-
1
0
0
0
2
1
4
°
5
9
'
3
5
"
9
1
4
4
0
2
0
0
0
STORMWATER OVERFLOW TRENCH
REFER TO DRAWING SO4
1
5
0
0
PROPOSED SHED BY OTHERS
STORMWATER TANK BY OTHERS
BATTER BANK
2
1
0
0
0
7
0
0
0
SITE PLAN
SCALE 1:200
SCALE: AS NOTED SHEET SIZE: A3 DWGs IN SET: 7
DRAWN BY: DRP
DESIGN CHK: RJJ
DESIGN BY: MRP
DRAFT CHK: -
DATE: 26.10.17PROJECT No: 17265 DWG No: S02 REV: 0
TITLE:
SITE PLAN
CLIENT:
PROJECT:
ADDRESS:
APPROVED: R.JESSON ACRED. No: CC5848I
STATUS:
CONSTRUCTION
DO NOT SCALE - IF IN DOUBT, ASK
THIS DOCUMENT MAY ONLY BE USED FOR THE PURPOSE FOR WHICH IT
WAS PREPARED. © RARE INNOVATION PTY LTD. ABN 51 619 598 257
REV:
0 ISSUED FOR CONSTRUCTION DRP
DATE:
26-10-17
DESCRIPTION: BY:
MATT FRASER
255 RELBIA RD, RELBIA
RETAINING WALL DESIGN
255 RELBIA RD, RELBIA
Version: 1, Version Date: 01/11/2017Document Set ID: 3661950Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623
PROPOSED NEW SHED BY OTHERS
APPROXIMATE NATURAL
GROUND SLOPE
BATTER END OF RETAINING WALL
NEW GROUND LEVEL
A WALL ELEVATION
SCALE 1: 100S04
SCALE: AS NOTED SHEET SIZE: A3 DWGs IN SET: 7
DRAWN BY: DRP
DESIGN CHK: RJJ
DESIGN BY: MRP
DRAFT CHK: -
DATE: 26.10.17PROJECT No: 17265 DWG No: S03 REV: 0
TITLE:
WALL ELEVATION
CLIENT:
PROJECT:
ADDRESS:
APPROVED: R.JESSON ACRED. No: CC5848I
STATUS:
CONSTRUCTION
DO NOT SCALE - IF IN DOUBT, ASK
THIS DOCUMENT MAY ONLY BE USED FOR THE PURPOSE FOR WHICH IT
WAS PREPARED. © RARE INNOVATION PTY LTD. ABN 51 619 598 257
REV:
0 ISSUED FOR CONSTRUCTION DRP
DATE:
26-10-17
DESCRIPTION: BY:
MATT FRASER
255 RELBIA RD, RELBIA
RETAINING WALL DESIGN
255 RELBIA RD, RELBIA
Version: 1, Version Date: 01/11/2017Document Set ID: 3661950Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623
"TASMAN" CAPPING BLOCK
FIXED TO "TASMAN BLOCK"
WITH 2 PART EPOXY ADHESIVE
IN HIGH USE AREAS
RETAINED SOIL
150
SLAB SHED & FOOTINGS BY OTHERS
NO FINES CONCRETE
SL82
A RETAINING WALL
SCALE 1:20S02
"TASMAN" BLOCK
100mm MIN COMPACTED
GRAVEL AT BASE
100 Ø SLOTTED AG PIPE AT 1:100 MIN FALL
WRAP IN GEOTEXTILE SOCK
CONNECT TO STORMWATER TANK.
1400 M
AX
450
1000
600
600
B STORMWATER OVER FLOW TRENCH
SCALE 1:20S02
BLUE METAL
Ø100 AG DRAIN
CONNECTED TO
STORMWATER TANK
TOP SOIL
SCALE: AS NOTED SHEET SIZE: A3 DWGs IN SET: 7
DRAWN BY: DRP
DESIGN CHK: RJJ
DESIGN BY: MRP
DRAFT CHK: -
DATE: 26.10.17PROJECT No: 17265 DWG No: S04 REV: 0
TITLE:
WALL SECTION
CLIENT:
PROJECT:
ADDRESS:
APPROVED: R.JESSON ACRED. No: CC5848I
STATUS:
CONSTRUCTION
DO NOT SCALE - IF IN DOUBT, ASK
THIS DOCUMENT MAY ONLY BE USED FOR THE PURPOSE FOR WHICH IT
WAS PREPARED. © RARE INNOVATION PTY LTD. ABN 51 619 598 257
REV:
0 ISSUED FOR CONSTRUCTION DRP
DATE:
26-10-17
DESCRIPTION: BY:
MATT FRASER
255 RELBIA RD, RELBIA
RETAINING WALL DESIGN
255 RELBIA RD, RELBIA
Version: 1, Version Date: 01/11/2017Document Set ID: 3661950Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623
-350
0
-300
0
-250
0
-200
0
-150
0
-1000
-500
0
500
100
0
150
0 2
000
250
0
3000
rth
E
W
S
34° 59
' 35"
9144
0
284° 31' 40"47244
214°
59'
35"
9144
0
104° 31' 40"47244
104° 31' 40"47244
EXISTINGRESIDENCE
ADJOINTINGDWELLING
EXISTING CARPORT
EXISTINGDRIVEWAY
2000
7000
2100
0
1500
0
PROPOSED NEW SHEDBY OTHERS21M x 7M x 4.1 M HIGH
D.P.
D.P.
D.P.
D.P.
DIRECT STORMWATER INTOWATERTANK. NEW 90dia.P.V.C. STORMWATER PIPE
WATER TANK,OVER FLOW TOGARDEN
SCALE 1:500SITE AND DRAINAGE PLAN
NOTE:
BOUNDARY LINE TO BE CONFIRMED ON SITE BYSURVEYOR, OR AN AUTHORISED PERSON.
ANY EXTERNAL WALL CLOSER THAN 900mm TOBOUNDARY MUST BE FIRE RATED.
FINAL POSITION OF NEW BUILDING TO BECONFIRMED BY REGISTERED SURVEYOR,BEFORE COMMENCEMENT OF WORKS.
TITLE:
REVISED DATE:
JOB No:
DRAWING NO.
CHECKER:
SCALE:
DATE:
DRAWN:
COPYRIGHT©T/A Lateral Architecture31 Thistle Street West,South Launceston, Tasmania.7249ABN: 75 430 740 379Telephone: (03) 6326 6100lateralarchitecture.com.au
Sunshine Trust
DESIGNER:
ENGINEERING DISCLAIMER: STRUCTURAL ENGINEERS CERTIFICATES MAY BE REQUIRED TO COVER AREAS OF STRUCTURAL DESIGN,WIND CONDITIONS AND/OR SOIL CONDITIONS. THIS WORK IS OUTSIDE THE SCOPE OF THIS DRAFTING SERVICE AND A COMPETENTSTRUCTURAL ENGINEER SHOULD BE ENGAGED. THESE PLANS SHOULD BE READ IN ACCORDANCE WITH ENGINNERING DRAWINGS.
DO NOT SCALE DRAWINGS. IF IN DOUBT - ASK
ACCREDITATION COMPLIANCE NUMBER = CC - 282 Z
IMPORTANT: IF DRAWING NOT LODGED OR PROCESSED WITH COUNCIL WITHIN 12 MONTHS OF LAST REVISION DATE, THEN PLEASE RETURN FOR REVIEW BEFORE PROCEEDING. FOLIO REFERENCE :
LOCAL COUNCIL : LAUNCESTON CITY COUNCIL
DISCLAIMER: LATERAL ARCHITECTURE ADVISES THAT THIS PLAN HAS BEEN DRAWN TO COMPLY WITH THE REQUIREMENTS OF THELOCAL AUTHORITIES. LATERAL ARCHITECTURE HOWEVER DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY ERRORS OROMMISSIONS IN THE PLANS DUE TO WRONGLY SUPPLIED INFORMATION, NOR FOR MISCONSTRUCTION OR INTERPRETATION.
1 : 500
S:\D
raw
ings\2
016\F
raser
LA
16-1
1\F
raser_
16-1
1 -
V2.r
vt
16-A
ug-1
7 1
2:5
8:3
3 P
M
K.Law
M.L.Hall
16-08-17
10-03-16
LA-16-11
01
PROPOSED NEW SHED255 RELBIA ROAD, RELBIA,7258FOR MR MATT FRASER
M.L.Hall
61042/1
RELBIA ROAD
Version: 1, Version Date: 01/11/2017Document Set ID: 3662063Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623
Ground Floor
0
Ceiling
3160
Roof Top
4098
650 230
4748
1500
2000
Ground Floor
0
Ceiling
3160
Roof Top
4098
TITLE:
REVISED DATE:
JOB No:
DRAWING NO.
CHECKER:
SCALE:
DATE:
DRAWN:
COPYRIGHT©T/A Lateral Architecture31 Thistle Street West,South Launceston, Tasmania.7249ABN: 75 430 740 379Telephone: (03) 6326 6100lateralarchitecture.com.au
Sunshine Trust
DESIGNER:
ENGINEERING DISCLAIMER: STRUCTURAL ENGINEERS CERTIFICATES MAY BE REQUIRED TO COVER AREAS OF STRUCTURAL DESIGN,WIND CONDITIONS AND/OR SOIL CONDITIONS. THIS WORK IS OUTSIDE THE SCOPE OF THIS DRAFTING SERVICE AND A COMPETENTSTRUCTURAL ENGINEER SHOULD BE ENGAGED. THESE PLANS SHOULD BE READ IN ACCORDANCE WITH ENGINNERING DRAWINGS.
DO NOT SCALE DRAWINGS. IF IN DOUBT - ASK
ACCREDITATION COMPLIANCE NUMBER = CC - 282 Z
IMPORTANT: IF DRAWING NOT LODGED OR PROCESSED WITH COUNCIL WITHIN 12 MONTHS OF LAST REVISION DATE, THEN PLEASE RETURN FOR REVIEW BEFORE PROCEEDING. FOLIO REFERENCE :
LOCAL COUNCIL : LAUNCESTON CITY COUNCIL
DISCLAIMER: LATERAL ARCHITECTURE ADVISES THAT THIS PLAN HAS BEEN DRAWN TO COMPLY WITH THE REQUIREMENTS OF THELOCAL AUTHORITIES. LATERAL ARCHITECTURE HOWEVER DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY ERRORS OROMMISSIONS IN THE PLANS DUE TO WRONGLY SUPPLIED INFORMATION, NOR FOR MISCONSTRUCTION OR INTERPRETATION.
1 : 100
S:\D
raw
ings\2
016\F
raser
LA
16-1
1\F
raser_
16-1
1 -
V2.r
vt
16-A
ug-1
7 1
2:5
8:3
4 P
M
Draftie
M.L.Hall
16-08-17
10-03-16
LA-16-11
02
PROPOSED NEW SHED255 RELBIA ROAD, RELBIA,7258FOR MR MATT FRASER
Designer
61042/1
SCALE 1:100SOUTH EAST ELEVATION
NOTE:
COLORBOND CLADDING FITTED TO ROOF AS PER AS1562INSTALLATION OF ROOF AND WALL CLADDING AND N.C.C. 3.5.1.
LEVELS PROVIDED ARE FOR LATERAL ARCHITECTURES PURPOSESONLY, AND ARE NOT TO BE USED AS CONSTRUCTION LEVELS. BUILDERMUST CONFIRM ALL LEVELS AND SLOPES OR BLOCK ON SITE BEFORECONSTRUCTION.
NATURAL GROUND LINE
SCALE 1:100NORTH EAST ELEVATION
NATURAL GROUND LINE
Boundary Line
Retaining Wall
Version: 1, Version Date: 01/11/2017Document Set ID: 3662063Version: 2, Version Date: 14/11/2017Document Set ID: 3669547Version: 1, Version Date: 07/12/2017Document Set ID: 3689623