refriapp company profile 2016
DESCRIPTION
RefriApp is an engineering specialised in the maintenance of HVAC and Refrigeration systems. Our main goal is to lead refrigeration engineers to a more professional environment with appropriate technologies.TRANSCRIPT
2
Effective cleaning and refrigerant gases recycling
Fri3Oil System is the only worldwide available technology that ensures the total cleaning of
R&AC circuits and refrigerant, recycling at the same time any halocarbon refrigerant .
Limpieza eficaz y reciclaje de gases refrigerantes
Fri3Oil System es el único sistema del mercado internacional que garantiza la completa limpieza de los circuitos frigoríficos, reciclando al mismo tiempo los gases refrigerantes para su posterior reutilización.
3
REFRIAPP COMPANY
REFRIAPP EMPRESA
4
INTERNATIONAL EXPANSION
EXPANSIÓN INTERNACIONAL
6
REFRIAPP SOLUTIONS
SOLUCIONES REFRIAPP
9
FRI3OIL SYSTEM 10
LIFA AIR 14
CLIMACHECK 16
METRECO 18
NEUTRONICS 19
LECOSYSTEM 20
ULTRAPROBE 100R&AC 22
ENGINEERING SERVICES
SERVICIOS DE INGENIERÍA
24
TRAINING AND EVENTS
FORMACIÓN Y EVENTOS
25
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
INDEX
ÍNDICE
4
We offer to the HVAC & refrigeration companies a broad number of special tools that help them to:
Comply with current regulations regarding: F-gases leaks control; ODP’s phase out; Systems implementation; Energy inspections and Certifications; Ducts cleaning, etc.
Provide effective measurement tools and tasks execution to refrigeration technicians.
A young and dynamic company backed by more than 40 years of experience in the refrigeration sector, and more specifically in the world of refrigerants, oils and the difficulties in the refrigerant circuits cleaning. There are techonological advances in any trade sector. We try to gather the best novelties for the refrigeration systems services worldwide.
MISSION
MISIÓN
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
REFRIAPP COMPANY
REFRIAPP EMPRESA
RefriApp es una ingeniería orientada a los profesionales del mantenimiento de instalaciones de refrigeración. Nuestro principal objetivo es perseguir una mayor profesionalización del mercado mediantes las tecnologías y los métodos apropiados.
RefriApp is an engineering specialised in the maintenance of HVAC and Refrigeration systems. Our main goal is to lead refrigeration engineers to a more professional environment with appropriate technologies.
Ofrecemos al sector de los profesionales de la refrigeración y el aire acondicionado una serie de herramientas especiales, que ayudan a:
Cumplir con las normativas vigentes en cuanto a: Control de fugas de gases fluorados; Reconversión de los equipos que utilizan HCFC’s a gases fluorados; Certificación del rendimiento en puestas en marcha; Inspecciones y certificaciones energéticas; Limpieza de conductos de ventilación y extracción, etc.
Dotar de medios eficaces de medición y ejecución de tareas al frigorista.
VISION
VISIÓN
RefriApp recoge el testigo de más de 40 años de experiencia en el sector de la refrigeración, y más concretamente en el mundo de los refrigerantes, aceites y la problemática de la limpieza de circuitos frigoríficos. Como en otros muchos sectores, la tecnología es cada vez más importante. Intentamos reunir las tecnologías más avanzadas en el mantenimiento de instalaciones para ponerlas a disposición del frigorista.
REFRIAPP IS MEMBER OF AEFYT
REFRIAPP ES MIEMBRO DE LA ASOCIACIÓN DE EMPRESAS DEL FRÍO Y SUS TECNOLOGÍAS (AEFYT)
Web Version Versión Web
5
A unique technology for cleaning circular and rectangular ducts
Lifa Air improves since 1988 the Indoor Air Quality
of any environment by integrating mechanics, electronics and information technology.
Una tecnología única para la limpieza de conductos circulares y rectangulares Lifa Air mejora la Calidad de Aire Interior (CAI) de cualquier ambiente, integrando mecánica, electrónica y tecnología de la información desde 1988.
6
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
INTERNATIONAL EXPANSION
EXPANSIÓN INTERNACIONAL
RefriApp works with clients from over 30 countries worldwide. In addition, we currently have official distributors to offer our services and products in 2o countries across Europe, South America, Africa, Asia and Oceania.
RefriApp trabaja con clientes de más 30 países en todo el mundo. Además, contamos actualmente con distribuidores autorizados de nuestros servicios y productos en 20 países repartidos por Europa, Sudamérica, África, Asia y Oceanía.
Argentina
Chile
Costa Rica
Colombia
Panama
Venezuela
Mexico
DAIKIN · BUREAU VERITAS · ART-KLIMA · TÜV RHEINLAND ·
MITSUBISHI · CARRIER · ELECCLISUR · ATISAE · RENFE · CAF · MTA ·
EULEN · GIROA · JOHNSON CONTROLS · FRIGOSA · CLIATEC ·
KNORR-BREMSE · INKOO · FRIGOSA · OCA ICP · EKINSA ·
FERROVIAL · TRANE · LENNOX · VESCOM · POWER SUPPORT ·
STULZ · ART-KLIMA · COPISA · TH MANTENIMIENTO ·
REFRIGERACIÓN CARRASCO · WABTEC · G.SOLDATOS & CO EE ·
PATENTES TALGO · KLIMALUFT MANTENIMIENTO · SGS · HITECSA ·
SC AB TECHNIC PROFESIONAL · SNCF FRANCE · M&M TECHNICAL
AUSTRALIA · NORFRIGO · GROUPE QUALICONSULT · FRIGICOLL ·
THERMOSYSTEM ...
SOME OF OUR CLIENTS ALGUNOS DE NUESTROS CLIENTES
Canada
7
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
Angola
Australia
Finland, Nederlands, Poland,
Hungary, Romania, France, Greece,
Germany, Czech Republic, Austria,
Italy, Switzerland, Belgium, Turkey,
United Kingdom, Portugal
Argentina
Kazakhstan
Morocco
Saudi Arabia
Spain
REFRIAPP HEADQUARTERS IN ALMERIA, SPAIN / SEDE DE REFRIAPP EN ALMERÍA, ESPAÑA
Israel
8
An intelligent approach for quick
inspection and leaks detection
Ultraprobe 100R&AC is ideal for locating
refrigerant leaks in very short periods of time, in
minutes in most of cases, thus saving time and
money to the installer.
Un enfoque inteligente para inspección y rápida
detección de fugas
Ultraprobe 100R&AC es ideal para localizar fugas de
refrigerantes en períodos de tiempo muy pequeños,
en pocos minutos en muchos casos, ahorrando de
esta manera, tiempo y dinero al instalador.
9
REFRIAPP SOLUTIONS
SOLUCIONES REFRIAPP
RefriApp offers to the professional a complete catalog of special applications for servicing HVAC & Refrigeration systems.
CLEANING
LIMPIEZA
R&AC CIRCUITS
CIRCUITOS FRIGORÍFICOS FRI3OIL SYSTEM
HVAC DUCTS
CONDUCTOS DE VENTILACIÓN Y EXTRACCIÓN LIFA AIR
DIAGNOSIS AND ANALYSIS
DIAGNÓSTICO Y ANÁLISIS
HVAC&R INSTALLATIONS PERFORMANCE
RENDIMIENTO DE INSTALACIONES FRIGORÍFICAS
CLIMACHECK
METRECO
REFRIGERANT IDENTIFICATION & ANALYSIS
IDENTIFICACIÓN Y ANÁLISIS DE REFRIGERANTES NEUTRONICS
TREATMENT OF REFRIGERANT LEAKS
TRATAMIENTO DE FUGAS
REMOTE DETECTION AND CONTROL
DETECCIÓN Y CONTROL A DISTANCIA LECO SYSTEM
LOCATION BY ULTRASOUNDS
LOCALIZACIÓN POR ULTRASONIDOS ULTRAPROBE 100R&AC
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
RefriApp ofrece al profesional un completo catálogo de aplicaciones especiales para el mantenimiento de instalaciones frigoríficas.
Web Version Versión Web
10
FRI3OIL SYSTEM
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
Fri3Oil System is the only fully automatic R&AC circuits cleaning system Worldwide 100% effective. It allows oils, acids, water and other substances removal from any R&AC system using halocarbon gases. It also allows the recycling of these gases.
Fri3Oil System es el único sistema automático de limpieza de circuitos frigoríficos del mercado mundial 100% eficaz, que permite la eliminación definitiva de los aceites, ácidos, agua y demás residuos de cualquier sistema frigorífico que utilice gases halocarbonados. Además permite el reciclaje de estos gases.
CLE
AN
ING
R&
AC
CIR
CU
ITS
LIM
PIE
ZA
DE C
IRC
UIT
OS F
RIG
OR
ÍFIC
OS
Today, there is a major problem in the refrigeration
and air conditioning industry due to the
hygroscopicity of the polyol ester oils, POE, which are
used with HFCs. These oils take humidity from the
ambient, becoming acidic. This acidity will harm the
compressor and other parts of the installation.
Using the existing system refrigerant for cleansing
without any need for other consumables / cleaning
agents, that might otherwise be harmful to the
refrigeration plant, Fri3Oil System allows oils, acids,
water and other substances removal of any R&AC
system.
Actualmente, existe un gran problema en la industria
de la refrigeración y el aire acondicionado, debido a la
higroscopicidad de los aceites polioléster, POE, que
son usados con los HFCs. Estos aceites, toman
humedad del ambiente, creando ésta en su seno
ácidos que atacan al compresor y demás partes de la
instalación.
Utilizando el mismo refrigerante de la instalación, sin
necesidad de usar consumibles ni de introducir
ningún elemento perjudicial al sistema, Fri3Oil System
permite la eliminación definitiva de los aceites, ácidos,
agua y demás residuos de cualquier sistema
frigorífico.
ENABLES: Quick and effective on site cleaning of systems following burn-out or breakdown.
PERMITE: Limpieza rápida y efectiva después de un quemado o avería; Reutilización de la mayor parte de los refrigerantes.
IMPROVES: The efficiency and operating performance of refrigeration plant, reducing running costs.
MEJORA: Rendimiento y eficiencia energética de las instalaciones, reduciendo los costes de operación de las mismas.
EXTENDS: The life of plant by removing harmful contents.
EXTIENDE: La vida útil de las instalaciones.
SAVES: Costly refrigerant disposal by incineration.
EVITA: Alto coste de incineración de refrigerantes contaminados; Calentamiento global derivado de esa misma incineración.
AVOIDS: The need to use solvents or cleaning agents to clean systems, by using the refrigerant itself as the cleaning medium.
SALVA: la necesidad de utilizar disolventes como agente de limpieza, utilizando el propio refrigerante de la instalación como agente de limpieza.
SHORTENS: The time required to carry out remedial maintenance to return the system to full operating performance and efficiency.
REDUCE: El tiempo de trabajo para dejar los sistemas en marcha de nuevo, en completa garantía.
MAIN APPLICATIONS PRINCIPALES APLICACIONES
CLIMATIZACIÓN. INNOVATION GALLERY. Outstanding Product. 2005
GENEVE’S SALON DES INVENTIONS. Gold medal. Environmental Value 2007
11
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
CLE
AN
ING
R&
AC
CIR
CU
ITS
LIM
PIE
ZA
DE C
IRC
UIT
OS F
RIG
OR
ÍFIC
OS
Fri3Oil System bases its operations on three main physical principles:
Miscibility / refrigerant solubility with oil and of course with acid.
Settling density of the refrigerant / water / oil-acid and acid pressure drag.
Liquids separation by refrigerants evaporation.
Other physical principles occur in the process, like the pressure differential between injection and suction.
Fri3Oil System basa su funcionamiento en tres principios físicos:
Miscibilidad / solubilidad del refrigerante con el aceite y por supuesto éste con el ácido.
Decantación de densidades del refrigerante/agua/aceite-ácido.
Separación de líquidos por evaporación del refrigerante.
Otros principios físicos actúan en el proceso de limpieza, como por ejemplo, la diferencia de presión entre la inyección y la aspiración.
1. Refrigerant Cylinder Botella Pulmón
2. Raise/Drop levels Subir/Bajar niveles
3. Water Agua
4. Liquid refrigerant Refrigerante líquido
5. Oil + Acids + Suspended Solids / residues Aceite + Ácidos + Sólidos en suspensión
6. Control sightglass Mirilla Control
7. Expansion device Dispositivo de Expansión
8. Liquids separator Trampa Separador de Líquidos
9. Compressor Compresor
10. REA (External Oil Contanier) REA (Recipiente Exterior de Aceite)
OPERATING PRINCIPLES PRINCIPIOS DE FUNCIONAMIENTO
FRI3OIL SYSTEM
1
4
3
5
6
7 9
10
8
2
Web Version Versión Web
12
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
1990
Release to the European market of the first R&AC circuits cleaning system called AKA Force. In Spain
it was named KimiCleaner.
Lanzamiento en Europa de la primera unidad para limpieza de circuitos denominada AKA Force. En España se llamó KimiCleaner.
2005
2004
Release of the Fri3Oil System V.E.A. 1 as the first automatic and
portable system for cleaning R&AC circuits.
Lanzamiento de Fri3Oil System V.E.A. 1 como primer sistema
automático portátil de limpieza de circuitos frigoríficos.
Release of the Fri3Oil System V.E.A. 2 to the market in Spain at
Madrid’s exhibition “Climatización’05”.
Awarded as Outstanding product in the Innovation Gallery of this
exhibition.
Lanzamiento comercial en España de Fri3Oil System V.E.A. 2 en la
Feria “Climatización´05” de Madrid.
Galardonado como producto destacado en la “Galería de la Innovación” de dicho salón.
CLE
AN
ING
R&
AC
CIR
CU
ITS
LIM
PIE
ZA
DE C
IRC
UIT
OS F
RIG
OR
ÍFIC
OS
FRI3OIL SYSTEM HISTORY. KEY MOMENTS HISTORIA DE FRI3OIL SYSTEM. MOMENTOS DESTACABLES
Valid for all Refrigeration and Air Conditioning systems.
Válido para ser usado en todas las instalaciones frigoríficas de la Refrigeración y del Aire Acondicionado.
Suitable for fixed and mobile equipment.
Apto para equipos fijos y móviles.
Valid for large, medium and small size equipment.
Válido para equipos de tamaño grande, mediano y pequeño.
High speed recovery and recycling of all halocarbon refrigerants: CFC’s, HCFC’s and HFC’s.
Recuperación y reciclaje de todos los refrigerantes halocarbonados a alta velocidad: CFC’s, HCFC’s y HFC’s.
System cleansing following a compressor motor burnout.
Limpieza de circuitos después de un compresor quemado.
Total elimination of system acidity.
Eliminación total de la acidez.
Water removal in installations where a heat exchanger gets communicated.
Extracción de agua en instalaciones donde se comunica un intercambiador de calor.
APPLICATIONS FOR THE INDUSTRY APLICACIONES PARA EL SECTOR
FRI3OIL SYSTEM
Conversion equipment from HCFC+MO to HFC+POE.
Reconversión de equipos con HCFC + MO a HFC + POE.
Refrigerants transfer.
Transvase de refrigerantes.
Optimization of refrigeration systems in CAP and
COP.
Optimización de instalaciones frigoríficas en CAP y COP.
Decontamination of equipment for raw materials
recycling.
Descontaminación y reciclaje de equipos que van a la
obsolescencia.
Ideal for VRV/VRF, Chillers, Supermarkets /
Hypermarkets, etc.
Ideal para VRV/VRF, enfriadoras, supermercados,
hipermercados, etc.
13
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
TRANFER IN LIQUID PHASE TRASVASE EN FASE LÍQUIDA
REFRIGERANTS REFRIGERANTES
MP R-401A
R-134a 70 kg/h ± 5%
HP
R-22
R-404A
R-407C
115 kg/h ± 5%
VHP R-410A 135 kg/h ± 5%
Awarded Gold medal for its Environmental Value at Geneve’s
Salon des Inventions 2007.
Galardonado con la medalla de Oro por su Valor Medioambiental en el Salón de las Invenciones en
Ginebra 2007.
2007
Bureau Veritas Certificate regarding: Internal circuits
cleaning performance, Refrigerant cleaning quality and
Transfer capacity.
Certificación Bureau Veritas que acredita: Limpieza total de
los circuitos, Calidad del reciclaje de los refrigerantes y capacidad
de transvase de estos.
2009 2008
Fri3Oil System evolution with its V.EA. 3 version.
Evolución de Fri3Oil System con el lanzamiento de la versión V.E.A. 3.
2013
Manufacture and distribution by RefriApp.
Fabricación y distribución por
parte de RefriApp.
CLE
AN
ING
R&
AC
CIR
CU
ITS
LIM
PIE
ZA
DE C
IRC
UIT
OS F
RIG
OR
ÍFIC
OS
FRI3OIL SYSTEM
RECOVERING/RECYCLING FEATURES PROPIEDADES RECUPERACIÓN/RECICLAJE
Required power Potencia requerida
2Kw. Single phase. 220V. AC. 50Hz/60Hz. 2Kw. monofásica. 220V. Alterna. 50Hz/60Hz
Measurement Dimensiones generales
660 x 400 x 630 mm
Weigth Peso
62 kg
Portability Portabilidad
4 wheels and 2 handles. 4 ruedas y 2 asas
Body Material carcasa
Stainless Steel Acero inoxidable
Machine Command
Gestión de la máquina
Touch screen with +20 languages
Pantalla táctil +20 idiomas
MAIN TECHNICAL FEATURES PRINCIPALES CARACTERÍSTICAS TÉCNICAS
This System cleansing improves the thermodynamic performance ot the plant, COP and Cooling Capacity, thus extendig the life of compressors”.
La limpieza interna de los circuitos frigoríficos mejora el rendimiento termodinámico de los sistemas, el COP y la Capacidad Frigorífica, alargando la vida útil de los compresores”.
“
14
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
CLE
AN
ING
HV
AC
DU
CTS
LIM
PIE
ZA
DE C
ON
DU
CTO
S D
E V
EN
TIL
AC
IÓN
LIFA Air fabrica equipamiento de vanguardia para la inspección y la limpieza de conductos de ventilación y aire acondicionado. LIFA mejora la Calidad de Aire de Interior (CAI) de cualquier ambiente, integrando mecánica, electrónica y tecnología de la información.
LIFA Air manufactures state-of-the-art equipment for inspection and cleaning of ventilation and a/c systems. Lifa Air improves the Indoor Air Quality (IAQ) of any environment by integrating mechanics, electronics and information technology.
Cleaning HVAC ducts on residential, transport and industrial sectors.
Limpieza de conductos de climatización en los sectores residencial, transporte e industrial.
Disinfection in cleanrooms, hospitals, schools, playgrounds, etc.
Desinfecciones en salas blancas, hospitales, centros educativos, guarderías, etc.
Grease cleaning on ducts and hoods in the hospitality sector.
Limpieza de grasas en conductos y campanas de extracción en el sector hostelero.
Facades cleaning.
Limpieza de fachadas.
Sealing cracks in ducts.
Sellado de roturas en conductos.
Application of antimicrobials, fire-proof coatings, etc. in ducts and pipes.
Aplicación de recubrimientos antimicrobianos, ignífugos, etc. en conductos y tuberías.
APPLICATIONS FOR CLEANING APLICACIONES DE LIMPIEZA
Improvement of Indoor Air Quality (IAQ).
Mejora de la Calidad de Aire Interior (CAI).
Increasing HVAC systems efficiency.
Incremento de la eficiencia de los equipos de climatización.
Avoid a healthy and pure enviroment for hosters.
Permite un ambiente sano y puro para los residentes del inmueble.
Increasing energy saving of HVAC systems.
Incremento del ahorro de energía en los equipos.
Reduction of maintaining costs.
Reducción de los costes de mantenimiento.
Increasing useful life and improvement of systems performance.
Incremento de la vida útil y mejora del rendimiento de sistemas y equipos.
Compliance with current regulations regarding HVAC systems.
Cumplir con la normativa vigente en cuanto a sistemas de climatización.
DUCT CLEANING PROFITS BENEFICIOS DE LA LIMPIEZA DE CONDUCTOS
Solutions for Indoor Air Quality
LIFA AIR Web Version Versión Web
15
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
CLE
AN
ING
HV
AC
DU
CTS
LIM
PIE
ZA
DE C
ON
DU
CTO
S D
E V
NETIL
AC
IÓN
LIFA AIR
CLEANING EQUIPMENT EQUIPAMIENTO PARA LA LIMPIEZA
LIFA Set Set LIFA
VILLA RESIDENTIAL COMMERCIAL INDUSTRIAL HOSPITAL
Types of cleaning works Tipos de trabajos de limpieza
Boats, trains, houses ducts Conductos de viviendas, barcos, trenes, etc.
Buildings and housing ducts Conductos en edificios y viviendas
Multipurpose for cleaning grease, applying disinfections and sealants Multipropósito para limpieza de grasas, desinfecciones o selllado de roturas
Very demanding projects for industrial cleaning Exigentes proyectos de limpieza industrial
Disinfection with maximum power Desinfección que requieren máx. potencia
Diameter ducts Diam. de conductos
70-400mm 100-400mm 300-800mm 400-1200mm 400-1200mm
Cleaning machine Máquina de limpieza
SpecialCleaner 2 SpecialCleaner 20PE SpecialCleaner 25 Multi CombiCleaner 40 Hydmaster 40
Drive Accionamiento
Electric Eléctrico
Electric Eléctrico
Electric Eléctrico
Pneumatic Neumático
Electric Eléctrico
Rotation speed Velocidad rotación
540rpm 550rpm 300-570rpm 0-760rpm 0-800rpm
Scope shaft
Alcance del eje 20m 20m 25m 40m 40m
Power Potencia
0.25wK (0.4HP) 0.37kW (0.5HP) 0.55kW (0.7HP) Max. Flow
Caudal Máx. 600 l/min 1.1kW (1.5HP)
Weight Peso
15kg 30kg 71kg 40kg 86kg
Vacuum unit Aspiradora de vacío
HepaClean 1100 AirClean 3500 HepaClean 4000
Air-flow / Pressure Caudal / Presión
300-1150m3/h 750Pa
3600m3/h 1400Pa
3850m³/h 1400Pa
Weight Peso
18kg 56kg 85kg
LIFA has a unique technology for cleaning rectangular ducts and robots por inspection, supervision and cleaning ducts”.
LIFA dispone de tecnología única para la limpieza de conductos rectangulares y circulares, así como robots de inspección, supervisión y limpieza de conductos”.
“
16
HV
AC
&R
IN
STA
LLA
TIO
NS P
ER
FOR
MA
NC
E
REN
DIM
IEN
TO
IN
STA
LAC
ION
ES F
RIG
OR
ÍFIC
AS
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
ClimaCheck es una unidad inteligente especializada en el registro de datos y cálculo de variables, especialmente desarrollada para realizar eficazmente “inspecciones de rendimiento”, junto con el software ClimaCheck, de sistemas de refrigeración, aire acondicionado y bomba de calor.
ClimaCheck is a smart unit specialized in data collection and parameters computation, developed to effectively carry out “performance inspections” of cooling, air conditioning and heat pump systems, along with ClimaCheck software.
Most HVAC/R systems are not working with the
efficiency which they were designed for, so it is
necessary to have a clear and accurate view of the
operating system.
ClimaCheck is the most complete energy efficiency analyzer for HVAC/R systems in the market. This product is a global reality for all data of any installation in terms of energy efficiency and thermodynamic efficiency.
Performance and wear detection inspection, or
problems in any of the components of a HVAC and
Refrigeration system can be made through ClimaCheck
software, collection data previously from the cooling
circuit. All non-intrusively process, along with the
installation.
La mayoría de los sistemas de refrigeración y a/a no
trabajan con la eficiencia con la que fueron diseñados,
por lo que es necesario tener una visión clara y
fidedigna del sistema en operación.
ClimaCheck es el analizador del rendimiento energético
de las instalaciones frigoríficas más completo del
mercado. Este producto es una realidad a nivel mundial
para obtener todos los datos de cualquier instalación,
en términos de eficiencia energética y de rendimiento
termodinámico.
Las inspecciones de rendimiento y detección de
desgastes o problemas en cualquiera de los
componentes de un sistema frigorífico se pueden hacer
a través del software de ClimaCheck, recogiendo los
datos previamente desde el circuito frigorífico. Todo de
manera no intrusiva con la instalación.
Energy efficiency control and analysis, and cooling performance of any HVAC/R facility.
Chequeo y análisis de la eficiencia energética y el rendimiento frigorífico de cualquier instalación de refrigeración y aire acondicionado.
Problems solving and problems location effectively.
Localización y resolución de problemas de manera efectiva.
Check each R-22 installation that becomes a system with HFC and polyolester oil (POE). Before-After analysis.
Chequeo de cada instalación de R-22 que pasa a ser una instalación con HFC y aceite de tipo polioléster (POE). Análisis previo-posterior
Documented maintenance with detailed information of all parameters.
Mantenimiento documentado con información detallada de todos los parámetros.
New products and systems development.
Desarrollo de nuevos productos y sistemas.
Setups, inspections and warranties.
Puesta en marcha, inspecciones y garantías.
Performance regular inspections in installations.
Inspecciones regulares del rendimiento de las instalaciones.
MAIN APPLICATIONS PRINCIPALES APLICACIONES
ACR NEWS AWARDS. Refrigeration. Product of the year 2009
WWF CLIMATE SOLVER 2011
CLIMACHECK to Measure is to Know
Web Version Versión Web
17
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
HV
AC
&R
IN
STA
LLA
TIO
NS P
ER
FOR
MA
NC
E
REN
DIM
IEN
TO
IN
STA
LAC
ION
ES F
RIG
OR
ÍFIC
AS
CLIMACHECK
MAIN CALCULATED PARAMETERS PRINCIPALES PARÁMETROS CALCULADOS
ClimaCheck offers solutions for local analysis -via laptop or remote- monitoring and alarms via Internet.
For these purposes, has a portable version, designed to perform measurements and adjustments in simple systems and quickly, and another fixed version that provides the energy consumption, compressors and performance systems monitoring in continuous time and via Internet.
ClimaCheck ofrece soluciones para el análisis de forma local –vía ordenador portátil o remoto– monitorización y alarmas a través de Internet.
Para ello, dispone de una versión portátil para campo, pensada para la realización de mediciones y ajustes en sistemas sencillos y de forma rápida, y otra versión fija que provee una monitorización mediante Internet del consumo de energía, compresores y rendimiento del sistema en tiempo continuo.
Coefficient of Permormance (COP): Cold & Heat (±5%).
Coeficiente de Rendimiento (COP): Frío y Calor (±5%).
Cooling and heating capacities (±7%).
Capacidad frigorífica y calorífica (±7%).
Electricity consumption (±2%).
Potencia eléctrica absorbida (±2%).
Compressor isentropic efficiency.
Eficiencia isentrópica del compresor.
Superheating / Subcooling.
Recalentamiento / Subenfriamiento.
Temperature difference between inlet and outlet of the evaporator / condenser.
Diferencias de temperaturas y caudales entre la entrada y la salida del evaporador / condensador.
Refrigerant mass flow.
Caudal másico de refrigerante.
Pressure and temperature at any point in the system.
Presión y Temperatura en cualquier punto de la instalación.
System Efficiency Index (SEI).
Índice de Eficiencia del Sistema (SEI).
ClimaCheck has numerous templates for monitoring and analysis of any installation. There are no limitations on the size, design or gas for the installation to be analyzed”.
ClimaCheck dispone de numerosas plantillas para la monitorización y análisis de cualquier instalación. No existen limitaciones en cuanto al tamaño, diseño o gas que utilice la instalación que se desea analizar”.
“
18
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
The wireless digital analyzer that measures and records HVAC and refrigeration system critical data in real-time, including the COP. With Metreco, it is possible to demonstrate the energy efficiency before and after the intervention on the refrigeration system and the savings that can be achieved.
Metreco allows technicians and refrigeration mechanics to save energy, time and money. Now the measurement is mobile and intelligent”.
Metreco permite a los técnicos y mecánicos de refrigeración ahorrar energía, tiempo y dinero. Ahora la medición es móvil e inteligente”.
El analizador digital inalámbrico que mide y registra los datos críticos del sistema frigorífico en tiempo real, incluido el COP. Con Metreco es posible demostrar la eficiencia energética antes y después de la intervención sobre el sistema frigorífico así como los ahorros alcanzados.
HV
AC
&R
IN
STA
LLA
TIO
NS P
ER
FRO
MA
NC
E
REN
DIM
IEN
TO
IN
STA
LAC
ION
ES F
RIG
OR
ÍFIC
AS
“
1. Charging station - case Maleta de transporte con estación de carga
2. Storage Almacenamiento
3. Lid with protective foam Tapa de espuma protectora
4. Handheld Consola portátil
5. Sensors Sensores
6. Charging LED LED de carga
7. Space for extra sensors Espacio para sensores adicionales
8. Socket for charging - cable 12V & 220V Enchufe para cable de carga 12V/220V
Measurement Medición
Dynamic real-time Dinámica en tiempo real
Measured parameters Parámetros medidos
Superheating, subcooling, ∆T, COP, CAP, etc. Recalentamiento, subenfriamiento, ∆T, COP, Capacidad frigorífica, etc.
Types of sensors Tipos de sensores
Temperature, high and low pressure, amp-probe with Rogowski coil, absolute vacuum, repeater Temperatura, alta y baja presión, intensidad tipo Rogoswki, vacío absoluto, repetidor de señal
Measuring range Rango de medida
+200m
Storage Almacenamiento
Customer and HVAC systems database Base de datos de clientes y sistemas frigoríficos
PC connection Conexión al PC
USB. No software needed USB sin de software
Reports and tests Informes y pruebas
Reporting and Audit Trail Elaboración de protocolos, certificados PED
Special KITs KITs especiales
NH3, CO2
MAIN TECHNICAL SPECIFICATIONS PRINCIPALES ESPECIFICACIONES TÉCNICAS
Smart Mobile Measuring
METRECO
1
3
4
6 5
7
8
Web Version Versión Web
19
NEUTRONICS
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
Thanks to Dispersive infrared (NDIR) technology, Neutronics determines the weight concentrations of refrigerants in an agile and accurate way”.
La tecnología NDIR (Infrarrojo No Dispersivo) de los equipos Neutronics que permite la determinación de la concentración de gases de forma ágil y precisa”.
“
RI-700H analyzer determines, quickly and accurately, the weight concentrations of refrigerants and provides a component breakdown of the blend ratios and air.“Blend-ID” analytical software quickly and accurately indicates the presence of blend refrigerants.
El analizador RI-700H determina, de forma rápida y precisa, las concentraciones en peso de los refrigerantes y proporciona un desglose de las relaciones de los componentes de la mezcla y el aire. El software analítico “Blend-ID” indica con precisión y rapidez la presencia de los refrigerantes de la mezcla.
Refrigerant detected Refrigerantes detectados
R22, R134a, R404A, R407C, R410A, HCs, etc.
Accuracy Precisión
±2%
Sample gas extraction Extracción de gas de muestra
Pressure from cylinder or system Presión desde la botella o el sistema
Temperature range Rango de temperatura
50 a 110ºF 10 a 44ºC
Response time Tiempo de respuesta
Less than 3 min Menos de 3 minutos
Humidity Humedad
0-95% RH non-condensing USB sin de software
Test sample size Tamaño de la muestra de prueba
5g
Test pressure Presión de prueba
50 to 500psi 3,5 a 35,5bar
User interface Interfaz de usuario
Graphic display, soft keys, built in printer Pantalla gráfica, teclas de función, impresora incluida
Weight Peso
10 lb 4,5kg
RI-700H TECHNICAL SPECIFICATIONS ESPECIFICACIONES TÉCNICAS MOD. RI-700H
REFR
IGER
AN
T ID
EN
TIF
ICA
TIO
N &
AN
ALI
SYS
AN
ALI
ZA
DO
RES D
E G
ASES R
EFR
IGER
AN
TES
Neutronics diseña y fabrica instrumentos rápidos, precisos y portátiles de análisis de refrigerante para los profesionales del sector en todo el mundo, ofreciéndoles herramientas precisas para evitar, entre otros problemas, la contaminación de gases en las instalaciones y realizar una gestión más precisa y responsable de los mismos.
Neutronics designs and manufactures rapid, accurate and portable refrigerant analysis instruments for HVAC/R professionals around the globe. These tools are used to prevent refrigerant contamination and carry out a more accurate and sustainable management thereof.
Web Version Versión Web
20
LECOSYSTEM
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
LEA
KS R
EM
OTE D
ETEC
TIO
N &
CO
NTR
OL
DETEC
CIÓ
N Y
CO
NTR
OL
FU
GA
S A
DIS
TA
NC
IA
The LECOsystem system provides a total solution to the
needs of control and detection refrigerant leaks in
commercial and industrial refrigeration facilities.
LECOsystem uses the fundamentals of thermodynamics,
monitoring the installation, in specific operating ranges
depending on the type of refrigerant used.
In case that the deviation of the operation of the
installation is detected, regarding refrigerant
thermodynamic curves, the system generates a local
alarm and notify by mobile the situation for immediate
intervention.
El sistema LECOsystem aporta una solución total a las
necesidades de control y detección de fugas de
refrigerante en instalaciones de frío comercial e
industrial.
El sistema utiliza los fundamentos de la termodinámica,
monitorizando la instalación, y supervisando que se
mantiene en los rangos específicos de funcionamiento
en función del tipo de refrigerante utilizado.
En el caso de que se detecte la desviación del
funcionamiento de la instalación respecto a las curvas
termodinámicas del refrigerante, el sistema generará
una alarma local así como notificará la situación por
GSM para su inmediata intervención.
MAIN TECHNICAL FEATURES PRINCIPALES CARACTERÍSTICAS TÉCNICAS
Applicable to units Válido para unidades
Cooling only, heat pump, inverter, VRV, centrifuges Solo frío, bomba de calor, inverter, VRV, centrifugas
Refrigerants Refrigerantes
HCFC: 22, 123, 124, 134A HCF: 236FA R401A, R401B, R402A, R402B, R404A R407C, R410A, R507, R413A, R422A
Digital inputs Entradas digitales
4
Digital outputs Salidas digitales
2, activation via SMS 2, activadas mediante SMS
Analog inputs Entradas analógicas
6, 3 for temp. probes & 3 for pressure transducers 6, 3 para sondas de Tª y 3 para sondas de presión
Alarms Alarmas
Sent by SMS to central station and user Envío por SMS a central receptora y a usuario
Communication mode Comunicación
SMS / GPRS (Ver. GPS)
Antenna Antena
GMS
Body Carcasa
ABS IP55 Insulation Aislante ABS IP55
Measurements / Weight Dimensiones / Peso
244 x 194 x 96mm / 3kg
LECOsystem is an electronic remote device that detects and controls refrigerants leaks on HVAC&R installations. The system monitors superheating, subcooling and discharge temperature of the refrigeration circuit.
LECOsystem es un dispositivo electrónico de control a distancia para la detección de pérdidas de refrigerante en instalaciones, a través de la supervisión del recalentamiento, subenfriamiento y temperatura de descarga del circuito frigorífico.
Web Version Versión Web
21
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
LEA
KS R
EM
OTE D
ETEC
TIO
N &
CO
NTR
OL
DETEC
CIÓ
N Y
CO
NTR
OL
FU
GA
S A
DIS
TA
NC
IA
LECOSYSTEM
OPERATING DIAGRAM DIAGRAMA DE FUNCIONAMIENTO
1. Temperature sensor Sensor de temperatura
2. Pressure sensor Sensor de presión
3. Superheating Recalentamiento
4. Subcooling Subenfriamiento
5. Discharge temperature Temperatura de descarga
6. Analog contacts Contactos analógicos
7. Digital contacts Contactos digitales
8. Modem Modem
9. SIM SIM
10. Alarm message Aviso Alarma
11. Eventual installation STOP Posible paro instalación
12. CRA notice Aviso CRA
13. User’s mobile Móvil Usuario
14. Operator’s mobile Móvil Operador
15. Analog controls Controles analógicos
LECOsystem accomplishes the requirements of the R.842 / 2006 regulations. It is the first commercially available that actually facilitates the detection of refrigerant leaks”. (Feb. 2008)
LECOsystem cumple con los requisitos de la Normativa R.842/2006, siendo el primero disponible en el mercado que facilita la detección de fugas”. (Feb. 2008)
“
2
15
2 1 1
1
4
5
3
6
7
8
9
10
11
12
13
14
4 5
3
22
ULTRAPROBE 100R&AC
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
LEA
KS L
OC
ATIO
N B
Y U
LTR
ASO
UN
DS
DETEC
CIÓ
N D
E F
UG
AS P
OR
ULT
RA
SO
NID
OS
Ultraprobe es el localizador portátil de fugas por ultrasonidos más avanzado. Esta herramienta detecta fugas de refrigerante en períodos de tiempo muy cortos y de una forma cómoda y sencilla.
Ultraprobe is the most advanced portable ultrasonic leak detector & valve tester for saving energy, time and money. It is a practical tool for any leak detection, steam trap inspection or troubleshooting program.
Refrigerant leaks, besides an environmental problem,
involve a huge loss of profitability in refrigeration plants.
The high cost of refrigerants requires a prompt and an
effective detection in order to ensure, today more than
ever, the survival of companies in the HVAC/R sector.
Ultraprobe is an ultrasonic receiver, which can detect
and locate any high frequency sound.
This tool is ideal for locating refrigerant leaks in very
short periods of time, in minutes in most of cases, thus
saving time and money to the installer.
Las fugas de refrigerante suponen, además del
problema medioambiental, una enorme pérdida de
rentabilidad en las instalaciones frigoríficas. El alto
coste de los refrigerantes hacen que su pronta y eficaz
detección sea, hoy más que nunca, vital para la
supervivencia de las empresas del sector.
Ultraprobe es un receptor de ultrasonidos, que puede
detectar y localizar cualquier sonido de alta frecuencia.
Esta pistola, es ideal para localizar fugas de
refrigerantes en períodos de tiempo muy pequeños, en
pocos minutos en muchos casos, ahorrando de esta
manera, tiempo y dinero al instalador.
Leak detection and vacuum.
Detecciones de fugas con presión y en vacío.
Leak detection in valve seats.
Detección de fugas en asientos y válvulas.
Leak detection in heat exchangers, boilers and condensers.
Detección de fugas en intercambiadores de calor, calderas y condensadores.
Steam trap inspection.
Inspección en trampas de vapor.
Leak detection in tanks, pipes, etc.
Detección de fugas de tanques, tuberías, etc.
Leak detection in compressors and pumps.
Detección de fugas de compresores y bombas.
Insulation of windows and doors inspection on cold rooms.
Inspección del aislamiento de puertas y ventanas en cámaras frigoríficas.
Leak tests with, and without pressure, on pressure
vessels and heat exchangers.
Pruebas de estanqueidad, con y sin presión, en recipientes a presión y en intercambiadores de calor.
APPLICATIONS FOR HVAC/R INDUSTRY VENTAJAS PARA EL SECTOR DEL FRÍO
Web Version Versión Web
23
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
LEA
KS L
OC
ATIO
N B
Y U
LTR
ASO
UN
DS
DETEC
CIÓ
N D
E F
UG
AS P
OR
ULT
RA
SO
NID
OS
ULTRAPROBE 100R&AC
ADVANTAGES OF ULTRASOUND VENTAJAS DEL ULTRASONIDO
1. UP100 pistol housing with LED bar graph meter Pistola UP100 con display indicador por LEDs
2. Scanning module Módulo de escaneo
3. Rubber focusing probe Focalizador de fugas
4. Stethoscope module & extension Módulo estetoscópico (contacto) y extensión
5. Warble tone generator & adapter Generador de tonos y adaptador
6. Deluxe noise attentuating headphones Auriculares resistentes para uso con casco de seguridad
7. Liquid Leak Amplifier Líquido amplificador de fugas
8. Light case Maleta ligera de transporte
Ultraprobe 100R&AC is a special Kit by RefriApp for refrigeration and air conditioning industry which can detect turbulences produced by a gas leak”.
Ultraprobe 100R&AC es el Kit, especialmente configurado por RefriApp para el sector de la refrigeración y el a/a, que detecta las turbulencias producidas en un escape de gas de una instalación”.
“
Ultrasound is very directional and localized.
El Ultrasonido es direccional y localizable.
Ultrasound can be easily blocked or shielded.
El Ultrasonido puede ser fácilmente bloqueado o protegido.
Ultrasound instruments can be used in noisy environments.
Los equipos por Ultrasonidos pueden utilizarse en entornos ruidosos.
Changes in Ultrasound provide early warning of potential problems
Los cambios en el Ultrasonido proporcionan una alerta temprana a los posibles problemas.
Ultrasonic technology is valid for detect all kind of gas leak: Refrigerants, N2, CO2,, Air, Water Steam, etc.
La tecnología por ultrasonidos es válida para detectar cualquier tipo de fuga de un gas: Refrigerantes, N2, CO2, Aire, Vapor de agua, etc.
Ultrasonic technology is Noninvasive and Harmless for the R&AC circuits.
Los equipos por ultrasonidos son No Invasivos e Inocuos en el interior de los circuitos frigoríficos.
Ultrasound instruments are easy to use.
Los equipos por Ultrasonidos son sencillos de utilizar.
1
2
3
4
5
6
7
8
24
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
ENGINEERING SERVICES
SERVICIOS DE INGENIERÍA
CLEANING R&AC CIRCUITS LIMPIEZA DE CIRCUITOS FRIGORÍFICOS
RefriApp makes available to professionals in the R&AC sector our experience in following scenarios:
Compressor mechanical failure or electrical failure, lack of lubricity, oil acidity, etc.
Conversions of R22+MO –> HFC+POE/PAG.
Water inlet due to a heat exchanger fracture.
RefriApp pone al servicio de los profesionales del sector de la refrigeración y del aire acondicionado su experiencia para afrontar con éxito cualquiera de los siguientes escenarios:
Rotura de compresor por falla mecánica o eléctrica, falta de lubricidad, acidez en el aceite, etc.
Reconversiones de R22+MO –> HFC+POE/PAG.
Entrada de agua por rotura en intercambiador de calor.
FRI3OIL SYSTEM UNIT RENTAL ALQUILER DE LA UNIDAD FRI3OIL SYSTEM
We offer to our customers our technologies also through rent of our R&AC circuit cleaning system, Fri3Oil Sytem, for specific cases:
Compressor failure because acidity.
Water inlet by a heat exchanger connected.
Conversion or retrofit of R22 facilities.
Inspection, search and solving other problems, etc.
Ofrecemos a nuestros clientes la posibilidad de acceder a nuestras tecnologías también mediante el alquiler eventual de nuestros sistemas para casos específicos:
Rotura de un compresor por acidez.
Entrada de agua por un intercambiador de calor comunicado.
Reconversión o retrofit de instalaciones de R22.
Inspección, búsqueda y resolución de otros problemas, etc.
The RefriApp technical staff, using the monitoring and analysis proper tools, like ClimaCheck, can handle:
Energy efficiency full reports.
Improvements reports, analysing before and after a cleaning on a circuit.
Troubleshooting.
El equipo técnico de RefriApp, usando las herramientas de medición y análisis apropiados, como Climacheck, ofrece:
Completos informes de eficiencia energética.
Reportes antes y después de una limpieza de circuitos para demostrar la mejora energética (retrofits R22).
Búsqueda y resolución de problemas.
We have an after-sales service center for Fri3Oil System repairs, national and worldwide. Our mechanics team will update your F3OS to a Brand new state.
Disponemos de un Servicio Postventa para la reparación de los equipos Fri3Oil Sytem . Nuestro equipo de mecánicos actualizarán su F3OS para dejarlo como nuevo.
REPAIR AND MAINTENANCE CENTER REPARACIÓN Y MANTENIMIENTO
OPTIMIZATION STUDIES FOR R&AC
INSTALLATIONS ESTUDIOS DE OPTIMIZACIÓN DE INSTALACIONES
FRIGORÍFICAS
Web Version Versión Web
25
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
TRAINING AND EVENTS
FORMACIÓN Y EVENTOS
SPECIFIC TRAINING COURSES CURSOS DE FORMACIÓN ESPECÍFICA
As a Training Center and dealing with so special technologies, We understand that the education is essential in order to achieve success in field or any refrigeration application.
Therefore our commitment to continuously offer different specific trainings of our tools, along the Spanish national territory, either in Spanish or English languages.
Como Centro de Formación, entendemos que ésta es esencial cuando afrontamos cualquier trabajo de campo, laboratorio o cualquier aplicación de la refrigeración y el a/a.
De ahí nuestro compromiso continuo en ofrecer cursos de formación específicos de nuestras herramientas por todo el territorio nacional, ya sea en castellano o en inglés.
AD HOC TRAINING FORMACIÓN AD-HOC
RefriApp offers training courses specifically designed for the professionals according to their needs.
We adapt the characteristics of the course (subject, level scenario, timing, number of students, etc.) and We teach on client’s own facilities for their convenience.
RefriApp ofrece a todos los profesionales del sector cursos de formación especialmente diseñados según sus necesidades.
Adaptamos las características del curso (temas, nivel, caso práctico, fecha de celebración, número de alumnos, etc.) y lo impartimos en las propias instalaciones del cliente para su mayor comodidad.
RefriApp organizes biannually this unique international
meeting which brings together an average of 50
professionals from 20 different countries each time.
In this 2-working-day event, theoretical and practical sessions about the special applications are organized.
RefriApp organiza de forma bianual, este encuentro internacional único en el que se dan cita en cada ocasión, una media de 50 profesionales del sector de la refrigeración de 20 países diferentes. En este evento de dos días de duración, se organizan jornadas técnicas teóricas y prácticas de las aplicaciones especiales que comercializamos.
‘FRI3OIL SYSTEM FAMILY’
THE INTERNATIONAL MEETING ENCUENTRO INTERNACIONAL
PRESENTATIONS & SEMINARS PRESENTACIONES Y SEMINARIOS
We keep seeking new technologies for the R&AC service trade. Thus, we perform periodically technical workshops and seminars to introduce these novelties to the professionals in a technical and practical way.
Distance is not a problem
Also, we gather engineers from different countries for 4-hours-webinars, in which we walk deep into our tools, show case studies and open a bustling debate.
En RefriApp estamos siempre buscando nuevas tecnológicas para el sector del mantenimiento de instalaciones frigoríficas. Así, organizamos frecuentemente jornadas técnicas y seminarios para presentar estas novedades a los profesionales de una manera técnica y práctica.
La distancia no es un problema
Asimismo, organizamos jornadas técnicas on-line en las que exponemos nuestras herramientas y métodos, casos de estudio y abrimos un vivo debate técnico entre profesionales de distintos países.
Web Version Versión Web
26
RefriApp Special HVAC & Refrigeration Applications Aplicaciones Frigoríficas Especiales
www.refriapp.com
Designed by: RefriApp.
All rights reserved.
Version: April 2016.
Before printing, please think about your responsibility and commitment to our environment.
Diseñado por: RefriApp.
Todos los derechos reservados.
Versión: Abril 2016.
Antes de imprimir, piense en su responsabilidad y compromiso con el medio ambiente.
27
The definitive HVAC energy efficiency analyzer
ClimaCheck is a smart unit specialized in data collection, developed to effectively carry out
“performance inspections” of cooling, air conditioning and heat pump systems
El analizador de los sistemas frigoríficos definitivo ClimaCheck es una unidad inteligente especializada en el registro de datos, especialmente desarrollada para realizar eficazmente “inspecciones de rendimiento” de sistemas de refrigeración, aire acondicionado y bombas de calor.
28
SPECIAL HVAC & REFRIGERATION APPLICATIONS
RefriApp, S.L.
Pol. Ind. La Juaida. C/ Sierra Alhamilla, 47
04240 Viator. Almería SPAIN
t. +34 950 30 44 79 m. +34 664 383 108