regupol vibration 1000 · width: 48" (1,219 mm) max. static load 218.0 psi peak loads (rare,...
TRANSCRIPT
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Regupol® Vibration 1000
Regupol® Vibration 1000Standard forms of delivery, ex Lebanon, PA
Rolls Thickness: 10 mm Length: 30' (9,144 mm) Width: 48" (1,219 mm)
Max. static load 218.0 psi
Peak loads (rare, short-term loads) 254.0 psi
Static modulus of elasticity Based on EN 826 580 - 1,5954.0 - 11.0
psiN/mm2
Tangential modulus, see figure “Modulus of elasticity”
Dynamic modulus of elasticity Based on DIN 53513 2,176 - 6,52715.0 - 45.0
psiN/mm2
Depending on frequency, load and thickness, see figure “dynamic stiffness”
Mechanical loss factor DIN 53513 0.16 [-] Load-, amplitude- and frequency-dependent
Compression set Based on DIN EN ISO 1856
4.9 % Measured 30 minutes after decompression with 50% deformation / 23 °C after 72 hrs
Tensile strength Based on DIN EN ISO 1798
336.62.3
psiN/mm2
Elongation at break Based on DIN EN ISO 1798
110 %
Tear resistance Based on DIN ISO 34-1 85.7 lbs/in
Sliding friction in-house laboratoryin-house laboratory
0.60.7
[-][-]
Steel (dry)Concrete (dry)
Compression hardness Based onDIN EN ISO 3386-2
1,650 kPa Compressive stress at 25 % deformationTest specimen h = 60 mm
Rebound elasticity Based on DIN EN ISO 8307
37 % Depending on thickness, Test specimen h = 60 mm
Force reduction DIN EN 14904 45 % Depending on thickness, Test specimen h = 60 mm
Ozone resistance DIN EN ISO 17025 Cracking stage 0
[-]
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Load Ranges
Load Deflection
Regupol® type
2.97.3
14.5
17.421.8
43.5
116.0
218.0
200 300 400 450 480 550 800 1000
Regupol® vibration M
ax.
sta
tic lo
ad
psi
0.020.05
0.10
0.120.15
0.30
0.80
1.50
N/mm2
Regupol® Vibration 1000
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Vibration Isolation
Natural Frequency
Regupol® Vibration 1000
Illustration of the isolation efficiency of a single-degree-of-freedom system (SDOF system) on a rigid base with
Regupol® vibration 1000. Parameter: power transmission (insertion loss) in dB, isolation factor in %.
200
180
160
140
120
100
80
60
40
20
4 8 12 16 20 24
natural frequency [Hz]
dis
turb
ing
freq
uen
cy [
Hz]
28 32 36 40
-40 dB / 99 %
-35 dB / 98 %
-30 dB / 97 %
-25 dB / 94 %
-20 dB / 90 %
-10 dB / 69 %
0 dB / 0 %
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Modulus of Elasticity
Dynamic Stiffness
Regupol® Vibration 1000
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Influence of Amplitude
Regupol® Vibration 1000
REGUPOL AMERICA LLC | 11 RITTER WAY LEBANON, PA 17042
REGUPOL-ACOUSTICS.COM | 1.717.675.2190
Technology on Your Wavelength
Long-Term Creep Test
Regupol America, LLC is a product manufacturer and does not represent itself as a consultant, engineer, or advisor in construction methods, standards, and compliance. Therefore, Regupol America only warrants its products under its standard limited warranty (available by request), and does not represent or warrant any advice, suggestions, instructions, whether formal or informal, oral or written, in conjunction with any sales of its products. Any such advice is not intended for a particular purpose and should not be acted or relied upon as such. Any such advice is not represented as being all-inclusive, correct, complete or up-to-date.
The information and data contained herein are based on industry accepted testing, manufacturing tolerances and prior product usage as set forth. It is intended as descriptive of the performance characteristics and capabilities of Regupol/Regufoam and does not certify applicability for any particular or specific project. Technical assistance, calculations and design recommendations are available from Regupol America, and are subject to terms and conditions provided upon request.
Regupol 1000, Version 1, Release 10/2015