relnot_vstitcher

Upload: julio-paucar

Post on 10-Feb-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/22/2019 relnot_VStitcher

    1/4

    Page 1 of 4

    AccuMark V-Stitcher by Browzwear Interface Module

    Software Release Notice

    8.5.1

    2012

    1. Release Contents

    This release contains

    One AccuMark Family DVD

    One AccuMark V-Stitcher DVD

    One document identified as:

    AccuMark V-Stitcher Interface Module Software Release Notice 8.5.1

    Note:Refer to AccuMark Release Notes for information on the AccuMark installation.

    Important Note:accumark plugin folder may difer in location from previous versions.Refer toAccuMark-V Stitcher_Additional Notes to Version 461- Installation.pdf for further detailsas for V Stitcher V 4.6.1 installation.

    2. Description

    AccuMark/ V-Stitcher Interface Module enables Model and Piece data to be transferred fromAccuMark

    Pattern Design Software to the V-Stitcher application.

    The AccuMark / V-Sticher interface software is installed on the workstation where V-Stitcher hasbeen installed. It provides additional menu selections (functions) under the V-Stitcher Plug-insmenu that are used to Import AccuMark Models (and pieces) from AccuMark storage areas andto Update the piece data within V-Stitcher when changes are made to the AccuMark Model andPiece data.

    3. System Requirements

    AccuMark V-Stitcher by Browzwear V4.6.1 (lower versions still compatible withAccuMark)

    AccuMark V8.3.1. or higher

    Recommended System:

    o Intel Core 2 Duo processor or highero Pentium 4 PC, 2.4 GHz or highero 2 Gb or more of RAMo 4 GB available hard disk spaceo Windows XP, Windows Vista or Windows 7o ATI Radeon 9800 Graphics card

    Min Requirements:o Pentium PCo 1 Gb of RAMo Graphic card: 16 Mb integrated, AGP with support for pixel / vertex shader 2.0o For Communication: HTTP Internet Connectiono Windows XP

    For enterprise configurations a fast Ethernet LAN at 100 MB/1GB is recommended.

  • 7/22/2019 relnot_VStitcher

    2/4

    Page 2 of 4

    Unsupported Operating Systems

    The following operating systems are not supported for AccuMark Family software with V-Stitcher. While

    you may be able to install this software, it is possible you will experience technical problems.

    Windows NT

    Windows 98SE

    Windows 95

    4. Software Installation Instructions

    IMPORTANT! Clock Date and Time:It is extremely important to check the date and time BEFORE proceeding with theinstallation of the software. Turning back the clock once the software has been installedand running will invalidate your software license!

    4.1 Installing the AccuMark V-Stitcher interface module V8.4.1

    IMPORTANT: Close any open programs before installing the software.

    Steps to Install

    1. Login to system as Administrator.

    2. Insert the AccuMark V-Stitcher V4.6.1 (lower versions still compatible with AccuMark)DVD into the DVD-ROM drive.

    3. Wait for the Autorun application splash window to appear in the screen.

    4. If the autorun does not display, Install the AccuMark V-Stitcher application by doubleclicking on the VSSetup.exe file for Windows XP or VSSetup-Vista.exe for WindowsVista and follow the instructions. This starts the installation. See the Installation.docfile in the Documents folder of the installation CD for detailed instructions. Completethe installation.

    5. Insert the AccuMark Family DVD, V8.4.1.xx (Lower versions of accumark maybe

    compatible), into the DVD-ROM drive. See the AccuMark Release Notes for detailedinstructions.

    6. Complete the AccuMark installation

    4.2 License Agreement

    When you run the AccuMark system for the first time after installing the software an approval of

    the licensing agreement is necessary. Once the affirmative response has been entered, the licensing

    agreement will not display again

    4.3 Directory Structure

    The installation creates the C:\USERROOT directory structure, which contains the data,required by the system. The default program files are located in the subdirectories under

    c:\program files\Gerber Technology, unless a different destination is chosen during theinstallation.

    5. Hardware & Software Security

    AccuMark Products use a combination of software based security technology and a hardware

    security key (dongle) to license and protect the software.

  • 7/22/2019 relnot_VStitcher

    3/4

    Page 3 of 4

    5.1 Hardware Securityattaching the key

    For a system running both AccuMark and V-Stitcher together, two keys and a license file are

    required. One key and license file for the AccuMark (sentinel) and one key for V-Stitcher (hasp).

    For a system running stand-alone V-Stitcher, two keys are also required; one key for the V-Stitcher

    (hasp) and a key and license file enabling the AccuMark interface (sentinel) is required.

    Attach the security key(s) (dongle) to the parallel and/or USB port of the PC or workstation. A

    Security License File is unique to each security key (dongle). The combination of key and license

    file will allow activation of the AccuMark Family software as stated in the software subscription

    contract.

    5.2 Retrieving your License File

    The security license file name is a combination of the product and key number with the file

    extension of .lic, for example accumark111.lic. Using the Install License program, copy the

    appropriate license file onto the system with the matching key number.

    If the license file was received through Email, save the attached file to a location on your hard

    drive or on the desktop (for example, c:\program files\common files\gerber technology\gt licensemanager). If the license file was received on a floppy, it may be installed directly from the floppy

    and/or copied to your hard drive.

    5.3 Software Security LicenseInstall License program

    The AccuMark Family Product CD installs an Install License program that easily copies your

    license file into the proper destination for use by AccuMark applications. Use the Install License

    icon on the Desktop, or from the LaunchPad on the "AccuMark Explorer/Utilities" page, or use the

    AccuMark V8 folder, select "AccuMark Explorer/Utilities" and then "Install License".

    A dialog box displays allowing you to choose the Product and source location for the license file

    (use the ellipses () button to locate your license file). Note the key number on the right had side

    of the dialog box and match to the right license file. Run the program once for each Product. The

    program, by default, looks for files of type .lic. It will prompt you to overwrite the existing licensefile if one already exists

    6. Starting AccuMark Professional Edition components

    Start the AccuMark applications from the following locations:

    1. From the Startmenu select the Gerber LaunchPad G icon or, from the Desktop,

    double click on the G icon if LaunchPad is not displayed. TheAccuMarkProfessional Edition LaunchPadmenu contains the selections for PatternProcessing, Digitizing and Pattern Design, Marker Creation, Editors, Plotting,Cutting, AccuMark Explorer and Utilities and documentation.

    2. In addition, from the Startmenu, applications can be accessed from the associatedprogram folders in AccuMark V8. Shortcuts to the desktop can also be createdfrom this location.

    7. Using AccuMark V-Stitcher interface

    1. From the StartMenu select V-Stitcher from the associated program folder menu andclick the icon V-Stitcher to open the application

    2. To open an AccuMark model into V-Stitcher, select AccuMakr from the PlugIns menu

    and then Import Model.

  • 7/22/2019 relnot_VStitcher

    4/4

    Page 4 of 4

    3. A listing of storage areas will be displayed where you can select the desired model.

    8. Support/Problem Reporting Procedure

    Customer Service support hours are from 8am until 7pm Eastern Standard Time. If you have aquestion or encounter a problem, please contact GTs Customer Service Department. Our toll freenumber 1-800-321-2448 can be called during support hours from anywhere in North America.

    International customers please contact your local Gerber Office or Agent and Distributor forassistance.

    9. Software Status Update

    Refer to the Configuration Notes and Whats New with AccuMark in the AccuMark documentationfolder, or the V-Stitcher Help for further up-to-date information relating to your software andinstallation.