remanufactured irrigation power units - … · ipu – remanufactured components case ih rp65,...

4
IPU – REMANUFACTURED COMPONENTS Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using remanufactured components at a competitive price. The units are reassembled to original OEM specifications, run strictly on diesel by using remanufactured engines and offer quality and reliability that few can match. Your Case IH dealer can help you maintain your power unit through regular oil changes and by performing the required maintenance checks. Also, see your Case IH dealer to order OEM or Remanufactured repair parts for your power unit, and for details on the entire family of Case IH IPUs. Additionally, you can enjoy peace of mind with a 2-year, 2,000 hour warranty (whichever comes first). This is equivalent to warranties offered on new products. REMANUFACTURED IRRIGATION POWER UNITS Gross Power (hp) 1500 1800 2000 2200 Engine Speed (RPM) 0 50 100 150 200 GROSS HORSEPOWER GROSS FUEL CONSUMPTION GROSS TORQUE RP65 RP85 RP110 RP135 RP165 Gross Fuel Consumption BSFC (lb/hp-hr) Engine Speed (RPM) 1000 1200 1500 1800 2000 2200 0.300 0.400 0.310 0.320 0.330 0.340 0.350 0.360 0.370 0.380 0.390 100 200 300 400 500 600 Gross Power (hp) 1500 1800 2000 2200 Engine Speed (RPM)

Upload: lamdan

Post on 26-Jul-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REMANUFACTURED IRRIGATION POWER UNITS - … · IPU – REMANUFACTURED COMPONENTS Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using

IPU

– RE

MAN

UFAC

TURE

D CO

MPO

NENT

S

Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using remanufactured components at a competitive price. The units are reassembled to original OEM specifications, run strictly on diesel by using remanufactured engines and offer quality and reliability that few can match.

Your Case IH dealer can help you maintain your power unit through regular oil changes and by performing the required maintenance checks. Also, see your Case IH dealer to order OEM or Remanufactured repair parts for your power unit, and for details on the entire family of Case IH IPUs.

Additionally, you can enjoy peace of mind with a 2-year, 2,000 hour warranty (whichever comes first). This is equivalent to warranties offered on new products.

REMANUFACTURED IRRIGATION POWER UNITS

Gro

ss P

ower

(hp)

1500 1800 2000 2200Engine Speed (RPM)

0

50

100

150

200

RP65 RP85 RP110 RP135 RP165

GROSS HORSEPOWER GROSS FUEL CONSUMPTIONGROSS TORQUE

Gro

ss P

ower

(hp)

1500 1800 2000 2200Engine Speed (RPM)

0

50

100

150

200

RP65 RP85 RP110 RP135 RP165

Gro

ss F

uel C

onsu

mpt

ion

BSFC

(lb/

hp-h

r)

Engine Speed (RPM)1000 1200 1500 1800 2000 2200

0.300

0.400

0.3100.3200.3300.340

0.3500.3600.3700.3800.390

RP135 RP65 RP110 RP135 RP165

100

200

300

400

500

600

RP65 RP85 RP110 RP135 RP165

Gro

ss P

ower

(hp)

1500 1800 2000 2200Engine Speed (RPM)

Page 2: REMANUFACTURED IRRIGATION POWER UNITS - … · IPU – REMANUFACTURED COMPONENTS Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using

Specifications RP65 RP85 RP110 RP135 RP165

Part Number 249995A1R 297110A1R 300117A1R 248544A1R 248542A1R

Engine Model 4391 4391T 4391TA 6591T 6591TA

Engine Type

4-cylinder, in line, 4-cycle, naturally aspirated with in-line injection pump

4-cylinder, in line, 4-cycle, turbocharged with in-line injection pump

4-cylinder, in line, 4-cycle, turbocharged/ aftercooled with in-line injection pump

6-cylinder, in line, 4 stroke cycle, turbo-charged with in-line injection pump

6-cylinder, in line, 4 stroke cycle, turbo-charged/aftercooled with in-line injection pump

Engine Displacement 239 cu in (3.9 liters) 239 cu in (3.9 liters) 239 cu in (3.9 liters) 360 cu in (5.9 liters) 360 cu in (5.9 liters)

Bore and Stroke 4.02 × 4.72 in (102 × 120 mm)

4.02 × 4.72 in (102 × 120 mm)

4.02 × 4.72 in (102 × 120 mm)

4.01 × 4.72 in (102 × 120 mm)

4.01 × 4.72 in (102 × 120 mm)

Compression Ratio 19.1:1 17.5:1 17.5:1 17.5:1 17.5:1

Governor Breakaway 2,275 rpm +/- 25 rpm 2,275 rpm +/- 25 rpm 2,275 rpm +/- 25 rpm 2,275 rpm +/- 25 rpm 2,275 rpm +/- 25 rpm

Governor Regulation 8% +/- 1% 8% +/- 1% 8% +/- 1% 8% +/- 1% 8% +/- 1%

High / Low Idle Speed 2,457 rpm (+/- 49 rpm) / 950 rpm (+/- 100 rpm)

2,457 rpm (+/- 49 rpm) / 950 rpm (+/- 100 rpm)

2,457 rpm (+/- 49 rpm) / 950 rpm (+/- 100 rpm)

2,457 rpm (+/- 49 rpm) / 1,000 rpm (+/- 100 rpm)

2,457 rpm (+/- 49 rpm) / 1,000 rpm (+/- 100 rpm)

Overall Weight 1,255 lbs (570 kg) 1,280 lbs (580 kg) 1,325 lbs (600 kg) 1,524 lbs (691 kg) 1,569 lbs (712 kg)

POWER UNIT PART NUMBERS & SPECIFICATIONS

Dimensions RP65 / RP85 / RP110 RP135 / RP165

Height to Top of Hood 48 in (1,219 mm) 48 in (1,219 mm)

Overall Height 70.25 in (1,784 mm) 71.50 in (1,816 mm)

Height to Center of PTO Shaft 16.5 in (419 mm) 16.5 in (419.1 mm)

Skid Width 30 in (762 mm) 30 in (762 mm)

Overall Width 30 in (762 mm) 30 in (762 mm)

Skid Length 48 in (1,219 mm) 58.5 in (1,485 mm)

Overall Length 61 in (1,549 mm) 71.5 in (1,816 mm)

Diameter of PTO Shaft 2.25 in (57 mm) 2.25 in (57 mm)

POWER UNIT DIMENSIONS

CONTINUOUS HORSEPOWER RATINGS

Description RP65 RP85 RP110 RP135 RP165

Rated Power (hp/kW)

60/45 @ 2200 rpm58/43 @ 2000 rpm54/41 @ 1800 rpm47/35 @ 1500 rpm39/29 @ 1200 rpm31/23 @ 1000 rpm

76/57 @ 2200 rpm78/59 @ 2000 rpm74/55 @ 1800 rpm65/49 @ 1500 rpm51/38 @ 1200 rpm39/29 @ 1000 rpm

99/74 @ 2200 rpm100/75 @ 2000 rpm95/71 @ 1800 rpm86/64 @ 1500 rpm53/40 @ 1200 rpm34/25 @ 1000 rpm

116/87 @ 2,200 rpm120/89 @ 2,000 rpm121/90 @ 1,800 rpm116/87 @ 1,600 rpm103/77 @ 1,400 rpm

148/110 @ 2,200 rpm156/116 @ 2,000 rpm158/117 @ 1,800 rpm146/109 @ 1,600 rpm126/94 @ 1,400 rpm

Rated Torque (lb-ft/Nm)

144/195 @ 2200 rpm153/208 @ 2000 rpm160/217 @ 1800 rpm167/227 @ 1500 rpm170/230 @ 1200 rpm166/225 @ 1000 rpm

183/248 @ 2200 rpm204/277 @ 2000 rpm215/292 @ 1800 rpm228/310 @ 1500 rpm220/299 @ 1200 rpm206/279 @ 1000 rpm

236/320 @ 2200 rpm262/355 @ 2000 rpm278/377 @ 1800 rpm299/405 @ 1500 rpm230/312 @ 1200 rpm180/244 @ 1000 rpm

274/371 @ 2,200 rpm313/425 @ 2,000 rpm349/473 @ 1,800 rpm378/512 @ 1,600 rpm384/521 @ 1,400 rpm

353/478 @ 2,200 rpm411/558 @ 2,000 rpm463/627 @ 1,800 rpm478/648 @ 1,600 rpm469/636 @ 1,400 rpm

PLEASE NOTE: Values stated in this document are from available data and are subject to change without notice.

FRONT VIEW

30 in (762 mm)

48 in

(1

,219

mm

)

RP13

5 / R

P165

71

.50

in (1

,816

mm

)

RP65

/ RP8

5 / R

P110

70

.25

in (1

,784

mm

)

16.5 in (419 mm)

RP65 / RP85 / RP110 61 in (1,549 mm)

RP135 / RP165 71.50 in (1,816 mm)

RP65 / RP85 / RP110 48 in (1,219 mm)

RP135 / RP165 58.5 in (1,485 mm)

SIDE VIEW

Page 3: REMANUFACTURED IRRIGATION POWER UNITS - … · IPU – REMANUFACTURED COMPONENTS Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using

POWER UNIT STANDARD FEATURES

Features RP65 RP85 RP110 RP135 RP165

PTO • • • • •

Removable Front Screen for Radiator Access and Cleaning • • • • •

Completely ISO-Mounted Engine for Smooth Operation • • • • •

Removable Side Panels for Engine Fan and Radiator Access, Cleaning and Inspection • • • • •

Fan Guards for Operator Protection • • • • •

Radial Air Cleaner for Quick Air Filter Maintenance • • • • •

Large, Easy-to-Read Instrumentation Panel Includes:

– Oil Pressure Gauge w/ Low-Pressure Shutdown • • • • •

– Coolant Temperature Gauge w/ High-Temperature Shutdown • • • • •

– Volt Meter • • • • •

– Tachometer w/ Digital Hour Meter • • • • •

– Emergency Shutdown Button • • • • •

– Dual Electrical Connection Posts for Convenient Addition of Shut Down Devices • • • • •

Starter: 12-Volt • • • • •

12-Volt, 65-Amp Alternator • • • • •

Remote Mount Battery Tray and Hold Down • • • • •

Removable Panel for Belt Access From Side Mounted Generator to the Double Crankshaft Pulley (if equipped) • • • • •

Skid w/ Fork Pockets for Easy Portability of the Power Unit • • • • •

Removable Front Screen for Radiator Access and Cleaning

Removable Side Panels for Engine Fan and Radiator Access, Cleaning and Inspection

Large, Easy-to-Read Instrumentation Panel

POWER UNIT FACTORY INSTALLED OPTIONS (ALL MODELS)

Features Part Number

Low Oil Shutdown 1347738C1

Double Groove Crankshaft Pulley J907982

Battery Cables 87299127

Low Oil ShutdownDouble Groove Crankshaft Pulley

Page 4: REMANUFACTURED IRRIGATION POWER UNITS - … · IPU – REMANUFACTURED COMPONENTS Case IH RP65, RP85, RP110, RP135 and RP165 Irrigation Power Units (IPUs) deliver optimum power using

PM-17065 (Replaces none) 04/2014©2014 CNH Industrial America LLC. All rights reserved. Case IH is a trademark registered in the United States and many other countries, owned by or licensed to CNH Industrial N.V., its subsidiaries or affiliates. CNH Industrial Reman is a trademark in the United States and many other countries, owned by or licensed to CNH Industrial N.V., its subsidiaries or affiliates. www.caseih.com

SOLD AND SERVICED BY:

PARTS ACCESSORIES (ALL MODELS)

Features Part Number

Driveshaft 73340124

Drive Hub (2.25 in PTO Shaft) 73340122

Battery, 950 CCA, Group 31 BMF31GW (US) CCMF31GW (CAN)

Double Groove Crankshaft Pulley (1/2 in or 5/8 in wide belt) J907982

Low Engine Oil Level Shutdown 1347738C1

Negative Battery Cable 87745688

Positive Battery Cable 87745689

ALLOWABLE SIDE-PULL LOADS – FOR STANDARD POWER TAKE OFFS

The following general information should be used for determining the actual applied load:

Maximum Allowable Side Load (lbs)

Distance of “X” Value Above

Clutch Size rpm 1 in 2 in 3 in 4 in 5 in

RP65 and RP85

10.0 in 1 Plate 1,000 2,470 2,190 1,730 1,430 1,216

10.0 in 1 Plate 1,500 2,420 2,190 1,730 1,430 1,216

10.0 in 1 Plate 2,000 2,230 2,070 1,730 1,430 1,216

RP110, RP135 and RP165

11.5 in 1 Plate 1,000 2,790 2,600 2,240 1,840 1,570

11.5 in 1 Plate 1,200 2,630 2,450 2,240 1,840 1,570

11.5 in 1 Plate 1,800 2,330 2,170 2,030 1,840 1,570

11.5 in 1 Plate 2,400 2,140 1,990 1,865 1,750 1,570

L = × F126,000 × HP

N × D

NOTE: Actual applied load must be less that the maximum allowable side load.

Where:L = Actual applied load (lbs) N = Shaft speed (rev/min) D = Pitch dia. of sheave (in) F = Load factor

1.0 For chain or gear drive 2.5 For all v-belt drives 3.5 For flat belt

NOTE: If the PTO is driving a large-inertia load or high-shock application, multiply the load by two.

Centerline of Side Load

SIDE VIEW OF PTO

Positive & Negative Battery Cables

Drive Hub

Driveshaft

950 CCA Battery