remote teller system - rts 41022812 vacuum air tube 21gx ... › pas › cut_sheets ›...
TRANSCRIPT
BACK VIEWSIDE VIEWFRONT VIEW
PLAN VIEW
NOTE:LOCATE IN OPERATORS KNEE SPACE AREA
A
B
133
")41(5
(2")
51
90
")169(3
69
")4
3(2
191
(1")
25
")16
9(7
57
")4
1(2
")161(1
28
(3")
76
")161(1
28
")16
11
(
17
(6")
152
")8
7 (22
A
B
VACUUM AIR TUBE 21GX CONTROL BOX
AND BLOWER PACKAGE ASSEMBLY
41022812 VACUUM AIR TUBE 21GX CONTROL BOX
Remote Teller SYSTEM - RTS®
BY DIEBOLD NIXDORF
WITH SHIELD, 300V (91-200212-0062)
2 CONDUCTOR, PVC INSULATION, TWISTED,
#20 GAUGE STRANDED TINNED COPPER,
TRANSFORMER CABLE - "HH" CABLE
DIEBOLD NIXDORF
WITH SHIELD, 300V (91-200212-0062) BY
2 CONDUCTOR, PVC INSULATION, TWISTED,
#20 GAUGE STRANDED TINNED COPPER
BLOWER CONTROL CABLE - "HH" CABLE
(91-200216-0062) BY DIEBOLD NIXDORF
7 CONDUCTOR, UNSHIELDED, 300V PP/PVC
#20 GAUGE STRANDED TINNED COPPER
CONTROL CABLE - "GG" CABLE
1828mm (6'-0")
TRANSFORMER CABLE
(3) CONDUCTOR
TYPE SJ, 12 AWG
PLAN VIEW
FRONT VIEW
SIDE VIEW
PERSPECTIVE
89
")21(3
525
")16
11
(1'-8
73
(1")
25
")16
13
(1'-4427
")8
7(2
227
")1615(8
167
")16
1(5
128
")16
9(6
206 ")8
1(8
230
")161(9
172
")43(6
")1611(1
43
")161(11
281
")1611(1
43")16
3(2
56
525
")1611(1'-8
UNIT IS HARD WIRED.
REQUIRED. MUST BE REMOVED WHEN
20 AMP DEDICATED BRANCH CIRCUIT
(1) 120 VAC, 60 HZ, SINGLE-PHASE (3W),
POWER CORD 1829mm (6'-0" LONG)
BLOWER HANGERS OR MOUNTING
") DIA. HOLES FOR 83(8) 10mm (
(6")
153
(6")
153
BLOWERS
FOR SERVICING
RECOMMENDED
CLEARANCE
AIR EXHAUST
SPRING LOADED
NOTE:
CLEARANCE RECOMMENDED FOR SERVICING BLOWERS
BLOWER WEIGHT 3.3 kg ( 7.2 LBS.)
BLOWER CAN BE MOUNTED VERTICALLY.
HARD WIRED INSTALLATION REQUIREMENTS.
WHEN HARD WIRED. SEE CUT SHEET FILE NUMBER 178-2080 FOR
OWNER'S E.C. TO PROVIDE "DISCONNECT" SWITCH TO BLOWER
WHEN LOCAL CODES SPECIFY HARD WIRE INSTALLATION.
SERVICEABILITY (BY OWNER'S E.C.). CONDUIT MAY BE REQUIRED
1,524mm (5'-0") OF FLEXIBLE CONDUIT TO ALLOW FOR
VACUUM AIR TUBE 21GX BLOWER PACKAGE ASSEMBLY
SEE PAGES 3 AND 4 OF 4
INSTALLATION
FOR HARD WIRED BLOWER
TO OPERATOR OR CUSTOMER UNIT
BY DIEBOLD NIXDORF
WITH SHIELD, 300V (91-200212-0062)
2 CONDUCTOR, PVC INSULATION, TWISTED,
#20 GAUGE STRANDED TINNED COPPER,
BLOWER CONTROL CABLE - "HH" CABLE
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
FIL
E N
O. 178-2
083 R
EV. 0
PA
GE 1 O
F 4
L1034
CALL 1-800-999-3600
FRONT VIEWSECTION VIEW
WOOD TRUSS OR BEAM
DIRECT MOUNTING
SECTION VIEW
BLOWER MOUNTING FROM SUSPENDED UNISTRUT SUPPORT WITH HANGERS
"-20) THREADED ROD41AND 6mm (
BLOWER MOUNTING FROM SUSPENDED UNISTRUT
BLOWER PACKAGE MOUNTING DETAILS
VACUUM AIR TUBE 21GX
Remote Teller SYSTEM - RTS
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 2 O
F 4
FIL
E N
O. 178-2
083 R
EV. 0
CALL 1-800-999-3600
UNISTRUT
UNISTRUT
CONTROL CABLES
WOOD BEAM
UNISTRUT
AIR NIPPLE
TO PNEUMATIC TUBE
") AIRLINE 2189 mm (3
CORDS
POWER
(6'-0") LONG
1829 mm
AIR NIPPLE
TO PNEUMATIC TUBE
") AIRLINE 2189 mm (3
"-20) THREADED ROD417mm (
8mm (516" -18) "J" HOOK
LOCAL PURCHASE
8mm (516")
"S" HOOK
LOCAL
PURCHASE
8mm (516") "S" HOOKS
LOCAL PURCHASE
8mm (516"-18) "J" HOOKS
LOCAL PURCHASE
8mm (516"-18)
"J" HOOKS
LOCAL PURCHASE
NOTE:
PERSPECTIVE
WHEN HARD WIRED.
OWNER'S E.C. TO PROVIDE "DISCONNECT" SWITCH TO BLOWER
WHEN LOCAL CODES SPECIFY HARD WIRE INSTALLATION.
SERVICEABILITY (BY OWNER'S E.C.). CONDUIT MAY BE REQUIRED
1,524mm (5'-0") OF FLEXIBLE CONDUIT TO ALLOW FOR
FRONT VIEW
SIDE VIEW
206 ")8
1(8
230
")161(9
172
")43(6
")1611(1
43
")161(11
281
")1611(1
43")16
3(2
56
525
")1611(1'-8
BLOWER HANGERS OR MOUNTING
") DIA. HOLES FOR 83(8) 10mm (
(6")
153
BLOWERS
FOR SERVICING
RECOMMENDED
CLEARANCE
AIR EXHAUST
SPRING LOADED
89
")21(3
525
")16
11
(1'-8
73
(1")
25
")16
13
(1'-4427
")8
7(2
227
")1615(8
167
")16
1(5
128
")16
9(6
(6")
153
PLAN VIEW
FOR SERVICING BLOWERS
CLEARANCE RECOMMENDED
WHEN HARD WIRED.
OWNER'S E.C. TO PROVIDE "DISCONNECT" SWITCH TO BLOWER
WHEN LOCAL CODES SPECIFY HARD WIRE INSTALLATION.
SERVICEABILITY (BY OWNER'S E.C.). CONDUIT MAY BE REQUIRED
1,524mm (5'-0") OF FLEXIBLE CONDUIT TO ALLOW FOR
BLOWER PACKAGE WEIGHT IS 3.3 kg. ( 7.2 LBS.)
BLOWER CAN BE INSTALLED VERTICALLY
BLOWER SHOWN IN A HORIZONTAL POSITION
HARD WIRED BLOWER INSTALLATION REQUIREMENTS
41022812 VACUUM AIR TUBE 21GX
Remote Teller SYSTEM - RTS
TO OPERATOR OR CUSTOMER UNIT
WITH SHIELD, 300V (91-200212-0062) BY DIEBOLD NIXDORF
2 CONDUCTOR, PVC INSULATION, TWISTED,
#20 GAUGE STRANDED TINNED COPPER,
BLOWER CONTROL CABLE - "HH" CABLE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 3 O
F 4
FIL
E N
O. 178-2
083 R
EV. 0
BOX
CONTROL
NOTES:
ELECTRICAL PHASE.
ALL CAMERAS, MONITORS AND VAT MATRIX SWITCHERS MUST BE ON THE SAME
ELECTRICAL SUPPLY PANEL.
ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT TO BUILDINGSB
A
B
A
LOCATE IN OPERATORS KNEE SPACE AREA.
C
A
B
A
B
BOX
CONTROL
( AIR LINE )
FLEXIBLE HOSE
PACKAGE
BLOWER
PACKAGE
BLOWER
PACKAGE
BLOWERPACKAGE
BLOWER
D
B
( BELDEN #8241 )
RG-59U COAX CABLE
( AIR LINE )
FLEXIBLE HOSE
( AIR LINE )
FLEXIBLE HOSE
( BELDEN #8241 )
RG-59U COAX CABLE
D
B
B
C
( BELDEN #8241 )
RG-59U COAX CABLE
(91-122021-5262)
DRAIN, COLOR CODED
STRANDED, FOIL SHIELD WITH
#22 AWG, 2 CONDUCTORS,
( BELDEN #8241 )
RG-59U COAX CABLE
MODULE
816 AUDIO CONTROL
( 21-016869-000-A )
4572mm ( 15'-0") MAX. LENGTH
AUDIO SWITCHER CABLE
TO RECORDING DEVICE
LOOPING OUTPUT
CUSTOMER CAMERA
TO RECORDING DEVICE
LOOPING OUTPUT
CUSTOMER CAMERA
(OPTIONAL)
SCAN CAMERA
( BELDEN #8241 )
RG-59U COAX CABLE
VAT VIDEO MATRIX SWITCHER-LOOPING
BVAT VIDEO MATRIX SWITCHER-LOOPING )
(REDUNDANCY)
(OPTIONAL)
POWER DOWN AND DISCONNECT FROM POWER
TESTED AT INSTALLATION
VIDEO ADVERTISING PACKAGE (OPTIONAL)
BLOCK
VOICE PHONE LINE
STANDARD DIAL-UP
( BELDEN #8241 )
RG-59U COAX CABLE
RCA-TYPE, STEREO PATCH CABLE
AUDIO ADVERTISING OPTION
A
B
C1
B
AA
B B
B
A
C
(91-122021-5262)
DRAIN, COLOR CODED
STRANDED, FOIL SHIELD WITH
#22 AWG, 2 CONDUCTORS,
B
RTS CUSTOMER STATIONS RTS OPERATOR STATION
POWER CORD
2444 mm (8'-0")
BOX
SWITCHER
AUDIO
(REDUNDANCY)
BOX
SWITCHER
AUDIO
OPTIONAL
DISCONNECT FROM POWER
TEST AT INSTALLATION
*
*
*
*
*
* *
*
* *
ON (1) 120 VAC, 60 Hz. SINGLE PHASE, (3W), 20 AMP DEDICATED BRANCH CIRCUIT.
OWNER'S ELECTRICAL CONTRACTOR TO PROVIDE (1) DUPLEX OUTLET AT EACH
ON (1) 120 VAC, 60 Hz. SINGLE PHASE, (3W), 20 AMP DEDICATED BRANCH CIRCUIT.
OWNER'S ELECTRICAL CONTRACTOR TO PROVIDE ( 1 ) DOUBLE DUPLEX OUTLET AT EACH
MONITORS ONLY."ON/OFF SWITCH TO CONTROL A MAXIMUM OF (4) CUSTOMER STATIONS.
CONTROLLED BY "ON/OFF" SWITCH IN OPERATOR AREA FOR CUSTOMER STATION
C C1
A
CUSTOMER MONITORS ONLY.
"ON/OFF" SWITCH FOR
C1
(14'-0") (29-016865-000A)
CABLE-4.267 METERS
RJ-45 INTERCONNECTING
BRANCH CIRCUIT.
SWITCH AT EACH "B" ON (1) 120 VAC. 60Hz, SINGLE-PHASE (3W) 20 AMP DEDICATED
ELECTRICAL CONTRACTOR TO PROVIDE (1) DUPLEX OUTLET AND (1) "DISCONNECT"D
D D
RTS - TYPICAL SCHEMATIC WITH HARD WIRED BLOWERS
(91-200212-0062) BY DIEBOLD NIXDORF
TWISTED WITH SHIELD, 300V
2 CONDUCTOR, PVC INSULATION,
#20 GAUGE STRANDED TINNED COPPER,
BLOWER CONTROL CABLE - "HH" CABLE
(91-200212-0062) BY DIEBOLD NIXDORF
TWISTED WITH SHIELD, 300V
2 CONDUCTOR, PVC INSULATION,
#20 GAUGE STRANDED TINNED COPPER,
BLOWER CONTROL CABLE - "HH" CABLE
(91-200216-0062) BY DIEBOLD NIXDORF
7 CONDUCTOR, UNSHIELDED, 300V PP/PVC
#20 GAUGE STRANDED TINNED COPPER,
CONTROL CABLE - "GG" CABLE
(91-200216-0062) BY DIEBOLD NIXDORF
7 CONDUCTOR, UNSHIELDED, 300V PP/PVC
#20 GAUGE STRANDED TINNED COPPER,
CONTROL CABLE - "GG" CABLE
(91-200216-0062) BY DIEBOLD NIXDORF
7 CONDUCTOR, UNSHIELDED, 300V PP/PVC
#20 GAUGE STRANDED TINNED COPPER,
CONTROL CABLE - "GG" CABLE
CODED (91-200170-0062) BY DIEBOLD NIXDORF
INDIVIDUAL FOIL SHIELDS WITH DRAIN, COLOR
TINNED COPPER, 3 SHIELDED TWISTED PAIRS,
AUDIO CABLE - "DD" CABLE #20 GAUGE STRANDED
B
A
BB
PR
OJE
CTIO
N
THIR
D A
NG
LE
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
(DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 4 O
F 4
FIL
E N
O. 178-2
083 R
EV. 0