renovation of bldg. 4032 mcas cherry point, … · renovation of bldg. 4032 mcas cherry point, nc...
TRANSCRIPT
PROJECT
AREA
RENOVATION OF BLDG. 4032MCAS CHERRY POINT, NC
A
A
A
B
C
D
A
B
C
D
12345678
1235678
RE
NO
VA
TIO
N O
F B
LD
G.
40
32
MC
AS
CH
ER
RY
PO
INT
, N
CR
EV
ISIO
N H
IST
OR
Y
FLE
ET
RE
AD
INE
SS
CE
NT
ER
EA
ST
U.S
. M
AR
INE
CO
RP
S A
IR S
TA
TIO
N, C
HE
RR
Y P
OIN
T, N
C
SHEET 2 OF 6
SCALE: 1/8" = 1'-0"
REV
SIZE
DCAGE CODE
96916
BUILDING 4032
MA
INT
EN
AN
CE
PLA
NN
ING
& S
US
TA
INM
EN
T D
IV D
WG
NO
RE
V
AP
PR
OV
ED
EN
VIR
FIR
E D
EP
T
OS
H
RE
VIE
WE
D
CH
EC
KE
D
DR
AW
N
DE
SIG
NE
R
ZO
NE
RE
VD
ES
CR
IPT
ION
DA
TE
WH
EN
PR
INT
ED
, IT
BE
CO
ME
S T
HE
US
ER
'S R
ES
PO
NS
IBIL
ITY
TO
DE
TE
RM
INE
CU
RR
EN
TN
ES
S O
F T
HIS
DR
AW
ING
. S
EE
RE
FE
RE
NC
E P
ED
QS
D-7
.3.7
-50
2.
4
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R
EA
ST
EF
FIC
IE
NS
A
GIL
IS
V
EL
OX
SEMPERFIDELIS
..
DEMOLITION NOTES:
GENERAL FACILITY NOTES:PROJECT SUMMARY:
1. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE INTERNATIONAL BUILDING CODE, 2012 EDITION, AS MODIFIED BY UFC 1-200-01, AND IN
ACCORDANCE WITH UFC 3-301-01 “STRUCTURAL ENGINEERING”, DATED 1 JUNE 2013, CHANGE 1, MAY 2014.
2. UNDER NO CIRCUMSTANCES SHALL REPRODUCTION OF CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DIMENSIONS, ELEVATIONS, ETC., NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE
STRUCTURE TO THE EXISTING STRUCTURE. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY PRIOR TO THE FABRICATION AND ERECTION OF STRUCTURAL MEMBERS.
4. BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING STRUCTURE, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH STRUCTURAL CONDITIONS OF THE EXISTING
STRUCTURE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY SAFEGUARDS, TO MAINTAIN ALL PARTS OF THE STRUCTURE IN A SAFE CONDITION AT ALL
TIMES DURING THE PROCESS OF CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE EXISTING BUILDING WHICH ARE TO REMAIN.
5. THE CONTRACTOR SHALL INFORM THE CONTRACTING OFFICER IN WRITING OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE
RESPONSIBILITY OF SUCH DEVIATION BY THE CONTRACTING OFFICER REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC. UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED
THE CONTRACTING OFFICER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE CONTRACTING OFFICER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION.
6. CONTRACTOR SHALL BE AWARE OF CHEMICAL AND PHYSICAL HAZARDS IN THE AREA THEY ARE GOING TO PERFORM WORK. IF DESIRED, THE CONTRACTOR MAY REQUEST, IN WRITING,
TO THE DESIGNATED FACILITY REPRESENTATIVE A COPY OF FRC EAST'S SAFETY DATA SHEETS FOR ALL HAZARDS NEAR WHICH THE CONTRACTOR WILL BE WORKING AND A COPY OF
THE FRCE HAZCOM PLAN. CONTRACTOR SHALL MANAGE ANY HAZARDOUS MATERIAL (HM) BROUGHT ON SITE IN ACCORDANCE WITH 29 CFR 1910.1200. CONTRACTOR SHALL SUBMIT
SAFETY DATA SHEET (SDS) DOCUMENTATION TO THE FRC EAST PROJECT MANAGER FOR ALL HM REGULATED SUBSTANCES (E.G. GLAZES, SEALANTS, CLEANERS, WELDING AND PAINTS)
BROUGHT INTO THE FACILITY FOR USE PRIOR TO BRINGING SUCH MATERIAL ON SITE. CONTRACTOR SHALL MAINTAIN SDSs ON SITE THROUGHOUT THE PROJECT. CONTRACTOR SHALL
ENSURE EMPLOYEES UNDERSTAND HOW TO LOCATE SDSs. CONTRACTOR SHALL COMPLETE FRC EAST FORM 5090/20 AND PROVIDE TO THE FRCE PROJECT MANAGER, WHO WILL, IN
TURN, PROVIDE THE FORM TO THE HAZARDOUS MATERIAL PROGRAM MANAGER. THE 5090/20 FORM CAN BE OBTAINED BY CONTACTING THE FRCE PROJECT MANAGER. ALL HM USED BY
CONTRACTOR WILL BE STORED ACCORDING TO THE SDS. ABSOLUTELY NO HM WILL BE LEFT ON SITE AT COMPLETION OF THE CONTRACT.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEAN-UP OF OCCUPIED SPACE AT THE COMPLETION OF EACH WORK PERIOD, COMPLETING CLEAN-UP IN TIME TO NOT CAUSE
INTERFERENCE WITH NORMAL FACILITY OPERATIONS. AFTER ALL CONSTRUCTION IS COMPLETE PER THIS DRAWING(S), THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL SCRAP
MATERIALS AND THOROUGHLY CLEAN THE CONSTRUCTION AREA.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND BE REQUIRED TO MAKE GOOD AT HIS OWN EXPENSE, ANY AND ALL DAMAGES TO ANY WORK OR MATERIALS IN PLACE ON THE
PREMISES, OR INCLUDED IN THIS CONTRACT, DURING THE EXECUTION OF THIS CONTRACT
WO: XG27618
FRC-EAST
PE
-21
65
4A
PR
OJ. S
UM
MA
RY
/ D
EM
OLIT
ION
. P
LA
N / G
EN
ER
AL N
OT
ES
BREAK
ROOM
CONF.
ROOM
OFFICE 1OFFICE 2
1034
OFFICE
ANNEX
1014
METAL
OFFICE 11013
METAL
OFFICE 2
1004
NDI
OFFICE1035
10361037
1A REMOVE EXISTING PARTITION AND FURNITURE.
REMOVE EXISTING CARPET AND RUBBER WALL BASE.
STEP A: RENOVATE OFFICE ANNEX 1034
TEMPORARILY STORE EXISTING FURNITURE TO OTHER
LOCATION OF THE BUILDING FOR NEW CARPET
INSTALLATION PER CLIENT'S INSTRUCTION.
STEP A WORK
BOUNDARY
DEMOLISH POWER CONDUIT POLE PER ELEC AND RESTORE
ANY DAMAGED CEILING TILE DURING DEMOLITION.
REMOVE EXISTING PARTITION AND FURNITURE.
REMOVE EXISTING CARPET AND RUBBER WALL BASE.
STEP B: RENOVATE METAL OFFICES / NDI OFFICE 1013
TEMPORARILY STORE EXISTING WORK BENCH AND
MOVE TO NEW LAB (EXISTING METAL OFFICE, 1014 ).
1014 1004
2A
3A
1B
2B
3B
1A 1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
2A
2A
2A
2A
2A
2A
2A
2A
2A
(NOT IN
CONTRACT)
3A
6A
3A
3A 3A
3A
1B 1B 1B 1B1B
2B2B
2B 2B
4B
4B1B
3B
REMOVE EXISTING DESKS / CUBICLES FROM LAB AREA.
STEP C: REMOVE EXISTING LAB FURNITURE/ WORK STATION
1C
1C 1C
1C
1C
STEP B
WORK BOUNDARY
1. THIS PROJECT INCLUDES RENOVATING EXISTING ANNEX OFFICE, METAL OFFICES AND NDI OFFICE OF THE
BUILDING 4032.
THE EXISTING FURNITURE AND PARTITIONS IN OPEN OFFICE AREA OF ANNEX OFFICE WILL BE REPLACED
WITH INCREASED NUMBER OF STANDARD WORKSTATIONS TO ACCOMMODATE EXISTING ADMIN
FUNCTION OF METAL OFFICES. THE EXISTING METAL OFFICE 1 WILL BE CONVERTED BACK TO LAB AREA.
THE METAL OFFICE 2 WILL BE RENOVATED TO LIBRARY SPACE. THE NEW WORK IS ALSO TO INCLUDE
RENOVATING NDI OFFICE INTO WHICH THE CURRENT 6 PERSONNEL ADMIN SPACES IN LAB AREA MOVE.
THE OVERALL WORK SCOPE INCLUDES NEW WORK STATIONS, RELOCATED FURNITURE, NEW FINISH
FLOORING AND NEW WALL PAINT AND ELECTRICAL CHANGE ACCORDING TO REVISED WORK STATION
AND OFFICE LAYOUT.
2. ELECTRICAL SCOPE IS TO INCLUDE RELOCATING NEW ELEC / COMM / DATA CONDUIT POLES IN
ACCORDANCE WITH THE NEW WORKSTATION LAYOUT.
4A
REMOVE EXISTING RUBBER STRIP.4A
5A
5A
5A TEMPORARILY REMOVE THRESHOLD FOR CARPET
INSTALLATION AND REUSE.
REMOVE EXISTING FLOORING VINYL SHEET. 4B5B 5B
5B
5B
REMOVE EXISTING TRANSITION STRIP. 5B
5A
1C
1C6B
TEMPORARILY STORE EXISTING CABINET AND MOVE TO
NEW LAB (EXISTING METAL OFFICE, 1014 ).
6B
6A REMOVE EXISTING CONFERENCE TABLE.
7A
7A REMOVE EXISTING WALL MOUNTED SHELVING.
2C
2C MOVE CONF. TABLE TO NEW LIBRARY (EXISTING METAL
OFFICE, 1013 ).
KEY PLANAREA OF WORK
F/N
: W
:\P
E-D
RA
WIN
GS
\ 21654A
_2-6
A-1
01.D
WG
(P
E-2
1654A
_2 A
-101)
1035 1036 1037
56'-03 8
"
38'-778
"
44'-0"
39'-0"
A
B
C
D
A
B
C
D
12345678
1235678
RE
NO
VA
TIO
N O
F B
LD
G. 4032
MC
AS
CH
ER
RY
PO
INT
, N
CR
EV
ISIO
N H
IST
OR
Y
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R E
AS
T
U.S
. M
AR
INE
CO
RP
S A
IR S
TA
TIO
N,
CH
ER
RY
PO
INT
, N
C
SHEET 3 OF 6
SCALE: 1/8" = 1'-0"
REV
SIZE
DCAGE CODE
96916
BUILDING 4032
MA
INT
EN
AN
CE
PLA
NN
ING
& S
US
TA
INM
EN
T D
IV D
WG
NO
RE
V
AP
PR
OV
ED
EN
VIR
FIR
E D
EP
T
OS
H
RE
VIE
WE
D
CH
EC
KE
D
DR
AW
N
DE
SIG
NE
R
ZO
NE
RE
VD
ES
CR
IPT
ION
DA
TE
WH
EN
PR
INT
ED
, IT
BE
CO
ME
S T
HE
US
ER
'S R
ES
PO
NS
IBIL
ITY
TO
DE
TE
RM
INE
CU
RR
EN
TN
ES
S O
F T
HIS
DR
AW
ING
. S
EE
RE
FE
RE
NC
E P
ED
QS
D-7
.3.7
-50
2.
4
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R
EA
ST
EF
FIC
IE
NS
A
GIL
IS
V
EL
OX
SEMPERFIDELIS
..
NEW WORK NOTES:
WO: XG27618
FRC-EAST
PE
-21654A
NE
W W
OR
K P
LA
N /
MA
TE
RIA
L A
ND
CO
LO
R S
CH
ED
UL
E
1A
STEP A: RENOVATE OFFICE ANNEX 1034
STEP B: RENOVATE METAL OFFICES AND NDI OFFICE 1013 1014
1014
2A
INSTALL NEW SHEET CARPET AND 6" RUBBER WALL BASE.
3A
PREPARE CLEAN AND SMOOTH WALL SURFACE AND APPLY NEW WALL PAINT.
TYP.
1A
1A
1A
1A
1A
1A
1A
1A
1A
(NOT IN
CONTRACT)
BREAK
ROOM
CONF.
ROOM
OFFICE 1 OFFICE 2
1034
OFFICE
ANNEX
1014
LAB
1013
1004
NDI
OFFICE
1035
1036 1037
LIBRARY
2A
2A
2A
2A2A
2A2A
2A
3A
3A
2A
1B
2B INSTALL NEW 2" RUBBER TRANSITION STRIP.
3B PREPARE CLEAN AND SMOOTH WALL SURFACE AND APPLY NEW WALL PAINT.
INSTALL NEW SHEET VINYL AND 6" RUBBER WALL BASE.
2B2B
5A
2B
3B
3B
3B
3B
3B
3B 3B
3B
3B 3B
3B
3B
3B
3B
3B
3B
4B
MATERIAL & COLOR SCHEDULE
WALL PAINT
RUBBER WALL BASE
ROPPE
PNNACLE DARK GRAY 6 INCH
OR APPROVED EQUAL
SHAW
CLASSIC 60756
OR APPROVED EQUAL
CARPET
COLOR: 50761
5B
RELOCATED WORK BENCH FROM NDI OFFICE
4B
4A
INSTALL NEW 2" RUBBER TRANSITION STRIP.
3A
NEW FILE
DRAWER(TYP.)
NEW
2'X4' DESK(TYP.)
INSTALL CARPET IN ACCORDANCE WITH THE CARPET
MANUFACTURER'S PRINTED INSTRUCTIONS AND THE
"CARPET AND RUG INSTITUTE"(CRI) STANDARD FOR
INSTALLATION OF COMMERCIAL TEXTILE COVERING
MATERIALS CRI-104.
PAINT APPLICATOR SHALL SATISFACTORILY APPLY
PAINT BY AIRLESS SPRAY OR BRUSH AT A MINIMUM
OF TWO COATINGS. MANUFACTURERS
SPECIFICATIONS SHALL GOVERN THE WORK.
4A
4A
REINSTALL EXISTING METAL THRESHOLD.
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A2A
5A
6B
RELOCATED CONF. TABLE FROM EXISTING LIBRARY.
NEW
BOOKCASE(TYP.)
1B
1B 2B2B
INSTALL NEW SHEET CARPET AND 6" RUBBER WALL BASE.
5B
5B
5B
NEW CONF.
TABLE (NIC)
NEW WORK STATION
(TYP.)
SHEET VINYL
IVC CHARCOAL 695 RANDOM
LOW-GLOSS FINISH SHEET VINYL
OR APPROVED EQUALKEY PLAN AREA OF WORK
RUBBER TRANSITION STRIP
ROPPE
#67 ROLLING TRAFIC TRANSITION 3/8" TO 1/8"
COLOR: DARK GRAY (#150)
OR APPROVED EQUAL
SHERWIN-WILLIAMS
PROMAR 200 ZERO VOC INTERIOR LATEX
EG-SHEL B26-2600 SERIES
COLOR: FS 27780 (FEDERAL STANDARD)
OR APPROVED EQUAL
6B
1004
RELOCATED CABINET FROM ROOM 1013
F/N
: W
:\P
E-D
RA
WIN
GS
\ 21654A
_3-6
A-1
02.D
WG
(P
E-2
1654A
_3 A
-102)
1035 1036 1037
5A
A
B
C
D
A
B
C
D
12345678
1235678
RE
NO
VA
TIO
N O
F B
LD
G. 4032
MC
AS
CH
ER
RY
PO
INT
, N
CR
EV
ISIO
N H
IST
OR
Y
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R E
AS
T
U.S
. M
AR
INE
CO
RP
S A
IR S
TA
TIO
N,
CH
ER
RY
PO
INT
, N
C
SHEET 4 OF 6
SCALE: 1/8" = 1'-0"
REV
SIZE
DCAGE CODE
96916
BUILDING 4032
MA
INT
EN
AN
CE
PLA
NN
ING
& S
US
TA
INM
EN
T D
IV D
WG
NO
RE
V
AP
PR
OV
ED
EN
VIR
FIR
E D
EP
T
OS
H
RE
VIE
WE
D
CH
EC
KE
D
DR
AW
N
DE
SIG
NE
R
ZO
NE
RE
VD
ES
CR
IPT
ION
DA
TE
WH
EN
PR
INT
ED
, IT
BE
CO
ME
S T
HE
US
ER
'S R
ES
PO
NS
IBIL
ITY
TO
DE
TE
RM
INE
CU
RR
EN
TN
ES
S O
F T
HIS
DR
AW
ING
. S
EE
RE
FE
RE
NC
E P
ED
QS
D-7
.3.7
-50
2.
F/N
: W
:\P
E-D
RA
WIN
GS
\ P
E-2
16
54
P_
4-6
E-0
01
.DW
G (
PE
-21
65
4P
_4
E-0
01
)
4
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R
EA
ST
EF
FIC
IE
NS
A
GIL
IS
V
EL
OX
..
WO: XG27618
FRC-EAST
PE
-21654P
EL
EC
TR
ICA
L L
EG
EN
D, A
BB
RE
VIA
TIO
NS
& G
EN
ER
AL
NO
TE
S
G1. ALL WORK SHALL BE EXECUTED AND COMPLETED BY A QUALIFIED CONTRACTOR
HOLDING A CURRENT ELECTRICAL CONTRACTORS LICENSE ISSUED BY THE STATE OF
NORTH CAROLINA BOARD OF EXAMINERS OF ELECTRICAL CONTRACTORS, IN
ACCORDANCE WITH THE PROVISIONS AND REQUIREMENTS OF CHAPTER 87, ARTICLE 4,
OF THE GENERAL STATUTES OR THE STATE OF NORTH CAROLINA. THE LICENSE SHALL
BE APPROPRIATE FOR BOTH THE SYSTEM VOLTAGE AND THE ESTIMATED DOLLAR
VALUE OF THE CONTRACT BEING BID. THE CONTRACTOR SHALL ENSURE ALL
MATERIALS USED AND WORKMANSHIP PERFORMED ARE OF THE HIGHEST QUALITY AND
STANDARDS.
G2. ALL WORK SHALL BE COMPLETED IN STRICT COMPLIANCE WITH THE ARTICLES AND
REQUIREMENTS OF THE "NATIONAL ELECTRICAL CODE", NFPA-70, CURRENT EDITION,
AND THE "STANDARDS FOR ELECTRICAL SAFETY IN THE WORK PLACE", NFPA-70E,
CURRENT EDITION AND IN STRICT COMPLIANCE WITH THE REQUIREMENTS SET FORTH
IN THE CFR 910.330 OSHA "REGULATIONS FOR ELECTRICAL SAFETY".
G3. ALL SAFETY AND OCCUPATIONAL CODE REQUIREMENTS INCLUDING; ANSI A10.32
PERSONAL FALL PROTECTION, EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS, 29 CFR
1910 OCCUPATIONAL SAFETY AND HEALTH STANDARDS, 29 CFR 1926 SAFETY AND
HEALTH REGULATIONS FOR CONSTRUCTION, 29 CFR 1926.500 FALL PROTECTION, NFPA
70 NATIONAL ELECTRIC CODE, AND NFPA 70E STANDARD FOR ELECTRICAL SAFETY
REQUIREMENTS FOR EMPLOYEE WORKPLACES.
G4. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PROVIDING ALL THE
NECESSARY LABOR, MATERIALS, COMPONENTS, AND EQUIPMENT (SUITABLE AND
CORRECT FOR THE INSTALLATION APPLICATION), TO PROVIDE A FULLY FUNCTIONAL
AND OPERATIONAL ELECTRICAL SERVICE TO THE EQUIPMENT. THIS SHALL INCLUDE,
BUT NOT BE LIMITED TO, PROVIDING THE CORRECT SIZE AND TYPE DISCONNECT
ENCLOSURE WITH THE APPROPRIATE CIRCUIT BREAKER, (VOLT, AMPERES, MINIMUM
10kAIC SYMMETRICAL INTERRUPTING RATING). PLACARDS SHALL BE PROVIDED AND
INSTALLED AS PER THE DETAIL.
G5. NO NEW CONDUIT RUNS SHALL INTERFERE WITH ANY OPERATING SYSTEMS; TO
INCLUDE BUT NOT LIMITED TO ELECTRICAL POWER SYSTEMS, LIGHTING SYSTEMS,
MECHANICAL SYSTEMS, AND FIRE SUPPRESSION SYSTEMS.
G6. THE CONTRACTOR SHALL COORDINATE PRIOR TO BEGINNING ANY AND ALL WORK TO
BE PERFORMED WITH THE FRC EAST PLANT ENGINEERING BRANCH POC, SHOP
SUPERVISORS AND/OR AREA PERSONNEL, ALONG WITH ALL OTHER TRADES
INVOLVED/ASSOCIATED WITH THE PROJECT. ALL WORK SHALL BE PERFORMED IN A
MANNER AS TO CAUSE MINIMAL OR NO IMPACT ON PRODUCTION AND ANY/ALL
AFFECTED AREAS IN ADDITION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
DETERMINING AND COORDINATING WITH ALL TRADES/PARTIES INVOLVED, ANY AND ALL
WORK REQUIRED TO BE PERFORMED TO SUPPORT OTHER TRADES INVOLVED IN THIS
PROJECT EVEN THOUGH NOT SPECIFIED IN THE PROJECTS DRAWINGS AND/OR
DOCUMENT. SCHEDULE POWER OUTAGES 15 DAYS IN ADVANCE.
G7. IT IS HIGHLY RECOMMENDED THAT THE CONTRACTOR VISIT THE WORK SITE PRIOR TO
BID SUBMISSION TO DETERMINE THE EXTENT OF THE WORK, TO VERIFY ALL
DIMENSIONS AND TO DETERMINE THE AMOUNT OF MATERIAL REQUIRED. LACK OF
KNOWLEDGE OF EXISTING CONDITIONS SHALL NOT BE ACCEPTED AS JUSTIFICATION
FOR THE SUBMISSION BY THE CONTRACTOR OF ANY CHANGE ORDERS PERTAINING TO
THIS PROJECT.
G8. ALL MATERIAL SHALL BE NEW AND SHALL BE "UL LISTED" WHEN APPLICABLE.
G9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL
DEBRIS, TRASH AND EXCESS MATERIAL FROM THE WORK SITE AND SHALL ENSURE
THAT THE WORK SITE IS RETURNED TO A "BROOM CLEAN" CONDITION AT THE END OF
EACH WORK SHIFT.
G10. ALL CIRCUITS SHALL BE TYPE WRITTEN AND PROPERLY IDENTIFIED IN SOURCE
PANELBOARDS. PANELBOARD SCHEDULES SHALL BE PROVIDED AND UPDATED WITH
EVERY NEW INSTALLATION AND DEMOLITION. CIRCUITS THAT ARE REMOVED SHALL BE
IDENTIFIED AS "SPARE".
G11. THE CONTRACTOR SHALL PROVIDE AN IDENTIFICATION PLACARD FOR EACH
PANELBOARD, DISCONNECT SWITCH, AND ANY OTHER ADDITIONAL SPECIFIED
EQUIPMENT/ITEM. PLACARD DETAILS SHALL BE INCLUDED AS NEEDED IN THE DRAWING
PACKAGE.
G12. ALL DEVICE COVERPLATES SHALL HAVE CIRCUIT NUMBER AND SOURCE PANELBOARD
IDENTIFICATION LABELS "P-TOUCH" TYPE, NOT HAND WRITTEN. (i.e. P/W20, CKT #5)
G13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND/OR REPLACING AT
HIS/HER OWN EXPENSE. ANY AND ALL RESPECTED DAMAGES INCURRED AND/OR
ASSOCIATED WITH THE WORK OR ANY NEGLIGENT ACTIONS PERFORMED.
G14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY AND
DETERMINE THE MOST EFFICIENT ROUTING FOR ALL INSTALLED CONDUIT RUNS
BASED ON FIELD CONDITIONS FOUND DURING THE INSTALLATION. A PRE-BID VISIT TO
THE WORK-SITE, WHEN APPLICABLE, TO DETERMINE THE ROUTING AND QUANTITY OF
CONDUIT AND FITTINGS REQUIRED IS STRONGLY RECOMMENDED. CONDUIT ROUTING
SHOWN ON DRAWINGS ARE POINT TO POINT REFERENCES ONLY, UNLESS SPECIFIED
OTHERWISE, AND SHOULD NOT BE USED AS INSTALLATION DRAWINGS, OR FOR
ESTIMATING INSTALLATION COSTS. TYPICALLY CONDUIT SIZES AND TYPES SHALL BE
SPECIFIED FOR INSTALLATION.
G15. FOR ANY ADDITIONAL ELECTRICAL CLARIFICATIONS AND WHEN THE INSTALLATION IS
COMPLETE, CONTACT THE FRC EAST FACILITIES INFRASTRUCTURE PLANNING AND
ENGINEERING SUPPORT TEAM, CODE 6.3.1, ELORA MERRY, 252-464-8831 TO ATTEND
THE FINAL INSPECTION.
C1. A PRE-BID SIT VISIT TO DETERMINE THE ROUTING AND QUANTITY OF CONDUIT AND
FITTINGS REQUIRED IS STRONGLY RECOMMENDED. CONDUIT ROUTING SHOWN ON
FRC-EAST DRAWINGS ARE POINT TO POINT REFERENCES AND SHOULD NOT BE USED AS
CONSTRUCTION DRAWINGS, OR FOR ESTIMATING INSTALLATION COST.
C2. ALL INSTALLED CONDUIT RUNS SHALL COMPLY WITH THE REQUIREMENTS OF THE
NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION THAT ARE APPLICABLE TO THE
TYPE AND SIZE OF CONDUITS INSTALLATED.
C3. ONLY ELECTRICAL METALLIC TUBING (EMT), GALVANIZED RIGID CONDUIT (GRC) AND
LIQUID TIGHT FLEXIBLE METALLIC CONDUIT (LTC) ARE APPROVED FOR USE IN FRC-EAST
FOR ABOVE GRADE INSTALLATION. POLY VINYL CHLORIDE CONDUIT (PVC) SCHEDULE 40
IS APPROVED FOR USE IN FRC-EAST FOR BELOW GRADE INSTALLATION.
C4. ONLY STEEL THREADED OR STEEL COMPRESSION TYPE FITTINGS ARE PERMITTED FOR
USE WITH TYPE GRC AND EMT CONDUIT. THE USE OF SET SCREW AND DIE CAST ZINC
FITTINGS IS PROHIBITED. LTC CONDUIT SHALL USE FITTINGS RATED FOR THE CONDUIT
AND SHALL MAINTAIN THE LIQUID TIGHT INTEGRITY OF THE CONDUIT AFTER
INSTALLATION.
C5. CONDUIT BODIES, PULL BOXES, AND JUNCTION BOXES SHALL BE CAST IRON, CAST
ALUMINUM OR GALVANIZED SHEET METAL, EITHER STAMPED OR WELDED
CONSTRUCTION IS ACCEPTABLE. ALL BOXES AND FITTINGS SHALL BE PROPERLY SIZED
AND SHALL BE APPROPRIATE FOR THE INTENDED USE.
C6. BENDS MAY BE MACHINE FORMED IN THE FIELD OR FACTORY FORMED, BUT SHALL
COMPLY WITH THE BENDING RADIUS SET FORTH IN THE NATIONAL ELECTRICAL CODE,
NFPA-70, CURRENT EDITION, FOR THE SIZE AND TYPE OF CONDUIT BEING FORMED.
C7. ALL CONDUIT RUNS SHALL BE TERMINATED WITH AN APPROVED FITTING LOCKNUTS AND
SHALL BE BUSHED WITH AN APPROVED BUSHING. WHERE A CONDUIT RUN IS
TERMINATED OUTSIDE AN ENCLOSURE THE TERMINATION FITTING SHALL PROVIDE FOR
EACH CONDUCTOR TO BE INDIVIDUALLY BUSHED AT THE EXIT POINT.
W1. ALL BRANCH CIRCUIT WIRE SHALL BE COPPER, PROPERLY SIZED, AND OF THE
APPROPRIATE TYPE FOR THE INTENDED USE, AND APPLIED LOAD AS ESTABLISHED IN
THE NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION. ALL INSTALLED WIRING
SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75° C.
W2. WHEN CALCULATING THE APPROPRIATE WIRE SIZE FOR A CIRCUIT THE AMPACITY OF
THE CIRCUIT SHALL BE BASED ON THE LOWEST TEMPERATURE RATING OF ANY ONE
COMPONENT IN THE CIRCUIT. EXAMPLE: IF A WIRE IS RATED FOR 90° C BUT THE
CONNECTING TERMINALS ARE RATED FOR 75° C, THEN THE ENTIRE CIRCUIT SHALL BE
RATED FOR 75° C.
W3. THE MINIMUM SIZE WIRE PERMITTED FOR USE ON ANY POWER CIRCUIT IS #12 AWG
REGARDLESS OF THE ANTICIPATED AMPERAGE OF THE CIRCUIT. THE USE OF ANY
WIRING SMALLER THAN #12 AWG REQUIRES APPROVAL FROM THE PLANT ENGINEERING
BRANCH, (CODE 6.3.617) PRIOR TO INSTALLATION.
W4. ALL RECEPTACLES AND SWITCHES SHALL BE COMMERCIAL GRADE OR BETTER.
W5. NO CIRCUIT SHALL BE CONTINUED THROUGH A DEVICE. IF THE CIRCUIT IS TO CONTINUE
THEN THE DEVICE SHALL BE CONNECTED TO THE CIRCUIT USING A PIG TAIL BETWEEN
THE CIRCUIT AND THE DEVICE. DEVICES RATED AT ABOVE 30 AMPS SHALL BE
CONNECTED TO THE CIRCUIT ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS
AND SPECIFICATIONS.
W6. ALL WIRING USED ON MULTI-PHASE CIRCUITS SHALL BE COLOR CODES AS SPECIFIED IN
THE NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION.
W7. ALL INSTALLED 120 VOLT SINGLE PHASE CIRCUITS SHALL HAVE A SEPARATE NEUTRAL
CONDUCTOR INSTALLED. NO SHARED NEUTRAL CONDUCTORS ARE PERMITTED.
W8. EACH CIRCUIT SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR IN THE CIRCUIT.
THE CONDUIT RUN SHALL NOT BE USED AS THE PRIMARY GROUND PATH FOR THE
CIRCUIT. ALL EQUIPMENT GROUNDS SHALL BE CLEARLY IDENTIFIED BY THE USE OF A
CONDUCTOR WITH INSULATION OR SHALL BE MARKED AT BOTH ENDS OF THE CIRCUIT
WITH AT LEAST THREE INCHES OF GREEN MARKING TAPE.
CONDUIT NOTES:GENERAL (ELECTRICAL) NOTES:
WIRE AND CABLE NOTES:
EXISTING TO REMAIN
EXISTING OR DEMOTION PLAN VIEW: TO BE REMOVED
NEW WORK PLAN VIEW: TO BE INSTALLED
20 AMP, 120 VOLT, DUPLEX RECEPTACLE
PANELBOARD
EXIT SIGN LIGHTING FIXTURE WITH BATTER PACK - CONNECT
AHEAD OF LOCAL SWITCH (EXISTING)
FIRE ALARM HORN/STROBE (EXISTING)
DATA NETWORK OUTLET, MOUNT 18" AFF, U.O.N. 4" SQUARE x
1-1/2" DEEP OUTLET BOX
ABOVE FINISHED FLOORAFF
ELECTRICAL METALLIC TUBINGEMT
TELEPHONE OUTLET, MOUNT 18" AFF, U.O.N. 4" SQUARE x 1-1/2"
DEEP OUTLET BOX
FIRE ALARM PULL STATION (EXISTING)F
TELE/DATA/POWER POLE
LEGEND AND ABBREVIATIONS
A
B
C
D
A
B
C
D
12345678
1235678
RE
NO
VA
TIO
N O
F B
LD
G. 4032
MC
AS
CH
ER
RY
PO
INT
, N
CR
EV
ISIO
N H
IST
OR
Y
FLE
ET
RE
AD
INE
SS
CE
NT
ER
EA
ST
U.S
. M
AR
INE
CO
RP
S A
IR S
TA
TIO
N, C
HE
RR
Y P
OIN
T, N
C
SHEET 5 OF 6
SCALE: 1/8" = 1'-0"
REV
SIZE
DCAGE CODE
96916
BUILDING 4032
MA
INT
EN
AN
CE
PLA
NN
ING
& S
US
TA
INM
EN
T D
IV D
WG
NO
RE
V
AP
PR
OV
ED
EN
VIR
FIR
E D
EP
T
OS
H
RE
VIE
WE
D
CH
EC
KE
D
DR
AW
N
DE
SIG
NE
R
ZO
NE
RE
VD
ES
CR
IPT
ION
DA
TE
WH
EN
PR
INT
ED
, IT
BE
CO
ME
S T
HE
US
ER
'S R
ES
PO
NS
IBIL
ITY
TO
DE
TE
RM
INE
CU
RR
EN
TN
ES
S O
F T
HIS
DR
AW
ING
. S
EE
RE
FE
RE
NC
E P
ED
QS
D-7
.3.7
-502.
4
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R
EA
ST
EF
FIC
IE
NS
A
GIL
IS
V
EL
OX
SEMPERFIDELIS
..
WO: XG27618
FRC-EAST
ELE
CT
RIC
AL D
EM
OLIT
ION
PLA
N
BREAK
ROOM
CONF.
ROOM
OFFICE 1OFFICE 2
1034
OFFICE
ANNEX
1014
METAL
OFFICE 11013
METAL
OFFICE 2
1004
NDI
OFFICE1035
10361037
(NOT IN
CONTRACT)
KEY PLAN AREA OF WORK
DEMOLITION WORK NOTES:
D1
D2
DEMOLISH EXISTING POWER POLES. DEMOLISH
ASSOCIATED SUPPORTS, WIRE AND CONDUIT BACK TO
EXISTING PANEL "PP1034". TURN BREAKERS OFF AND
UPDATE PANEL DIRECTORY WITH "SPARE".
EXISTING DATA DROP ASSOCIATED WITH THE
WORKBENCH TO BE RELOCATED. PROVIDE BLANK
COVER PLATE AT EXISTING DATA OUTLET LOCATION.
EXISTING ELECTRICAL TO REMAIN, UNLESS OTHERWISE
NOTED.
D2
D1
D1D1
D1
D1
D1
D3.
F/N
: W
:\P
E-D
RA
WIN
GS
\ P
E-2
1654P
_5-6
E-1
01.D
WG
(P
E-2
1654P
_5 E
-101)
PE
-21654P
A
B
C
D
A
B
C
D
12345678
1235678
RE
NO
VA
TIO
N O
F B
LD
G. 4032
MC
AS
CH
ER
RY
PO
INT
, N
CR
EV
ISIO
N H
IST
OR
Y
FLE
ET
RE
AD
INE
SS
CE
NT
ER
EA
ST
U.S
. M
AR
INE
CO
RP
S A
IR S
TA
TIO
N, C
HE
RR
Y P
OIN
T, N
C
SHEET 6 OF 6
SCALE: 1/8" = 1'-0"
REV
SIZE
DCAGE CODE
96916
BUILDING 4032
MA
INT
EN
AN
CE
PLA
NN
ING
& S
US
TA
INM
EN
T D
IV D
WG
NO
RE
V
AP
PR
OV
ED
EN
VIR
FIR
E D
EP
T
OS
H
RE
VIE
WE
D
CH
EC
KE
D
DR
AW
N
DE
SIG
NE
R
ZO
NE
RE
VD
ES
CR
IPT
ION
DA
TE
WH
EN
PR
INT
ED
, IT
BE
CO
ME
S T
HE
US
ER
'S R
ES
PO
NS
IBIL
ITY
TO
DE
TE
RM
INE
CU
RR
EN
TN
ES
S O
F T
HIS
DR
AW
ING
. S
EE
RE
FE
RE
NC
E P
ED
QS
D-7
.3.7
-502.
4
FL
EE
T R
EA
DIN
ES
S C
EN
TE
R
EA
ST
EF
FIC
IE
NS
A
GIL
IS
V
EL
OX
SEMPERFIDELIS
..
NEW WORK NOTES:
WO: XG27618
FRC-EAST
ELE
CT
RIC
AL N
EW
WO
RK
PLA
N
N1
N2
N3
N1 (NOT IN
CONTRACT)
BREAK
ROOM
CONF.
ROOM
OFFICE 1 OFFICE 2
1034
OFFICE
ANNEX
1014
LAB
1013
1004
NDI
OFFICE
1035
1036 1037
LIBRARY
KEY PLAN AREA OF WORK
N1
N1
UNLESS NOTED OTHERWISE, EXISTING ELECTRICAL
POWER, LIGHTING, AND FIRE ALARM TO REMAIN, NO
WORK REQUIRED.
REMOVED FROM SCOPE.
REUSE EXISTING SPARE 20 AMP, 1PH CIRCUIT BREAKERS
IN PANEL PRESENTLY RESERVED FOR THIS AREA.
PROVIDE AND INSTALL 6 #12 THHN & 2 #12 THHN GND, IN
3/4" EMT CONDUIT FROM PANELBOARD TO A JUNCTION
BOX LOCATED ABOVE THE DROP CEILING THE POWER
POLE LOCATION.
REUSE EXISTING SPARE 20 AMP, 1PH CIRCUIT BREAKERS
IN PANEL "PP1034" PRESENTLY RESERVED FOR THIS
AREA. PROVIDE AND INSTALL 2 #12 THHN & 1 #12 THHN
GND, IN 3/4" EMT CONDUIT FROM PANELBOARD TO NEW
RECEPTACLE LOCATION. VERIFY COLOR OF COVER
PLATES WITH CONTRACTING OFFICER PRIOR TO START
OF THIS WORK.
EXISTING TELEPHONE
BACKBOARD
N3
N3
N3
N4
N5
N6
RELOCATE EXISTING DATA DROP ASSOCIATED WITH THE
WORKBENCH BEING RELOCATED FROM THE NDI OFFICE
1004 TO THE LAB 1014. COORDINATE HEIGHT OF DROP
WITH CONTRACTING OFFICER PRIOR TO START OF THIS
WORK.
PROVIDE AND INSTALL EMPTY 3/4" EMT CONDUIT WITH
PULL STRING FROM EXISTING TELEPHONE ROOM TO NEW
TELE/DATA OUTLETS. COORDINATE LOCATIONS WITH
CONTRACTING OFFICER PRIOR TO START OF THIS WORK.
PROVIDE NEW TYPE WRITTEN PANEL DIRECTORY UPON
COMPLETION.
PROVIDE AND INSTALL NEW DEVICE COVERPLATES, AS
REQUIRED, TO MATCH EXISTING.
ALL NEW AND EXISTING DEVICE COVERPLATES SHALL
HAVE CIRCUIT NUMBER AND SOURCE PANELBOARD
IDENTIFICATION LABELS "P-TOUCH" TYPE, NOT HAND
WRITTEN. (I.E. R, CKT #30).
N4
N5
N6
N7
N8.
N9.
TELECOMMUNICATIONS
BACKBOARD
(EXISTING)
N3
TELE/DATA &
POWER POLE
3/4" EMT TO EACH DEVICE
1. TERMINATE EACH CONDUIT AT TOP OR BOTTOM EDGE OF
BACKBOARD WITH INSULATING BUSHING.
2. LEAVE 6' COIL OF PULL STRING AT BACKBOARD.
3. LEAVE 18" COIL OF PULL STRING AT EACH OUTLET.
TELECOMMUNICATION NOTES:
N7
N7
F/N
: W
:\P
E-D
RA
WIN
GS
\ P
E-2
1654P
_6-6
E-1
02.D
WG
(P
E-2
1654P
_6 E
-102)
PE
-21654P
A B C D
A B C D
12
34
56
78
12
35
67
8
RENOVATION OF BLDG. 4032MCAS CHERRY POINT, NC REVISION HISTORY
FLEET READINESS CENTER EAST
U.S. MARINE CORPS AIR STATION, CHERRY POINT, NCSH
EE
T 7
OF
7
SC
ALE
: 1/8
" = 1
'-0"
RE
V
SIZ
E
DC
AG
E C
OD
E
96
91
6
BU
ILD
ING
4032
MAINTENANCE PLANNING & SUSTAINMENT DIV DWG NO REV
APPROVED
ENVIR
FIRE DEPT
OSH
REVIEWED
CHECKED
DRAWN
DESIGNER
ZONE REV DESCRIPTION DATE
WHEN PRINTED, IT BECOMES THE USER'S RESPONSIBILITY TO DETERMINE
CURRENTNESS OF THIS DRAWING. SEE REFERENCE PEDQSD-7.3.7-502.
4
FLEET READINESS CENTER
EAST
EFFICIENS AGILIS VELOXSEMPER FIDELIS
. .
WO
: XG
27618
FR
C-E
AS
T
PE-21654A
NEW WORK PLAN / MATERIAL AND COLOR SCHEDULE
1034
OF
FIC
E
AN
NE
X
1014
LA
B
1013
1004
ND
I
OF
FIC
E
LIB
RA
RY
KE
Y P
LA
NA
RE
A O
F W
OR
K
F/N: W:\PE-DRAWINGS\ 21654A_3-6 A-102.DWG (PE-21654A_3 A-102)
PH
AS
E 1
PH
AS
E 2
PH
AS
E 2
PH
AS
E 2