Page 1: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

PROJECT

AREA

RENOVATION OF BLDG. 4032MCAS CHERRY POINT, NC

A

A

Page 2: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A

B

C

D

A

B

C

D

12345678

1235678

RE

NO

VA

TIO

N O

F B

LD

G.

40

32

MC

AS

CH

ER

RY

PO

INT

, N

CR

EV

ISIO

N H

IST

OR

Y

FLE

ET

RE

AD

INE

SS

CE

NT

ER

EA

ST

U.S

. M

AR

INE

CO

RP

S A

IR S

TA

TIO

N, C

HE

RR

Y P

OIN

T, N

C

SHEET 2 OF 6

SCALE: 1/8" = 1'-0"

REV

SIZE

DCAGE CODE

96916

BUILDING 4032

MA

INT

EN

AN

CE

PLA

NN

ING

& S

US

TA

INM

EN

T D

IV D

WG

NO

RE

V

AP

PR

OV

ED

EN

VIR

FIR

E D

EP

T

OS

H

RE

VIE

WE

D

CH

EC

KE

D

DR

AW

N

DE

SIG

NE

R

ZO

NE

RE

VD

ES

CR

IPT

ION

DA

TE

WH

EN

PR

INT

ED

, IT

BE

CO

ME

S T

HE

US

ER

'S R

ES

PO

NS

IBIL

ITY

TO

DE

TE

RM

INE

CU

RR

EN

TN

ES

S O

F T

HIS

DR

AW

ING

. S

EE

RE

FE

RE

NC

E P

ED

QS

D-7

.3.7

-50

2.

4

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R

EA

ST

EF

FIC

IE

NS

A

GIL

IS

V

EL

OX

SEMPERFIDELIS

..

DEMOLITION NOTES:

GENERAL FACILITY NOTES:PROJECT SUMMARY:

1. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE INTERNATIONAL BUILDING CODE, 2012 EDITION, AS MODIFIED BY UFC 1-200-01, AND IN

ACCORDANCE WITH UFC 3-301-01 “STRUCTURAL ENGINEERING”, DATED 1 JUNE 2013, CHANGE 1, MAY 2014.

2. UNDER NO CIRCUMSTANCES SHALL REPRODUCTION OF CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DIMENSIONS, ELEVATIONS, ETC., NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE

STRUCTURE TO THE EXISTING STRUCTURE. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY PRIOR TO THE FABRICATION AND ERECTION OF STRUCTURAL MEMBERS.

4. BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING STRUCTURE, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH STRUCTURAL CONDITIONS OF THE EXISTING

STRUCTURE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY SAFEGUARDS, TO MAINTAIN ALL PARTS OF THE STRUCTURE IN A SAFE CONDITION AT ALL

TIMES DURING THE PROCESS OF CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE EXISTING BUILDING WHICH ARE TO REMAIN.

5. THE CONTRACTOR SHALL INFORM THE CONTRACTING OFFICER IN WRITING OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE

RESPONSIBILITY OF SUCH DEVIATION BY THE CONTRACTING OFFICER REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC. UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED

THE CONTRACTING OFFICER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE CONTRACTING OFFICER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION.

6. CONTRACTOR SHALL BE AWARE OF CHEMICAL AND PHYSICAL HAZARDS IN THE AREA THEY ARE GOING TO PERFORM WORK. IF DESIRED, THE CONTRACTOR MAY REQUEST, IN WRITING,

TO THE DESIGNATED FACILITY REPRESENTATIVE A COPY OF FRC EAST'S SAFETY DATA SHEETS FOR ALL HAZARDS NEAR WHICH THE CONTRACTOR WILL BE WORKING AND A COPY OF

THE FRCE HAZCOM PLAN. CONTRACTOR SHALL MANAGE ANY HAZARDOUS MATERIAL (HM) BROUGHT ON SITE IN ACCORDANCE WITH 29 CFR 1910.1200. CONTRACTOR SHALL SUBMIT

SAFETY DATA SHEET (SDS) DOCUMENTATION TO THE FRC EAST PROJECT MANAGER FOR ALL HM REGULATED SUBSTANCES (E.G. GLAZES, SEALANTS, CLEANERS, WELDING AND PAINTS)

BROUGHT INTO THE FACILITY FOR USE PRIOR TO BRINGING SUCH MATERIAL ON SITE. CONTRACTOR SHALL MAINTAIN SDSs ON SITE THROUGHOUT THE PROJECT. CONTRACTOR SHALL

ENSURE EMPLOYEES UNDERSTAND HOW TO LOCATE SDSs. CONTRACTOR SHALL COMPLETE FRC EAST FORM 5090/20 AND PROVIDE TO THE FRCE PROJECT MANAGER, WHO WILL, IN

TURN, PROVIDE THE FORM TO THE HAZARDOUS MATERIAL PROGRAM MANAGER. THE 5090/20 FORM CAN BE OBTAINED BY CONTACTING THE FRCE PROJECT MANAGER. ALL HM USED BY

CONTRACTOR WILL BE STORED ACCORDING TO THE SDS. ABSOLUTELY NO HM WILL BE LEFT ON SITE AT COMPLETION OF THE CONTRACT.

7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEAN-UP OF OCCUPIED SPACE AT THE COMPLETION OF EACH WORK PERIOD, COMPLETING CLEAN-UP IN TIME TO NOT CAUSE

INTERFERENCE WITH NORMAL FACILITY OPERATIONS. AFTER ALL CONSTRUCTION IS COMPLETE PER THIS DRAWING(S), THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL SCRAP

MATERIALS AND THOROUGHLY CLEAN THE CONSTRUCTION AREA.

8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND BE REQUIRED TO MAKE GOOD AT HIS OWN EXPENSE, ANY AND ALL DAMAGES TO ANY WORK OR MATERIALS IN PLACE ON THE

PREMISES, OR INCLUDED IN THIS CONTRACT, DURING THE EXECUTION OF THIS CONTRACT

WO: XG27618

FRC-EAST

PE

-21

65

4A

PR

OJ. S

UM

MA

RY

/ D

EM

OLIT

ION

. P

LA

N / G

EN

ER

AL N

OT

ES

BREAK

ROOM

CONF.

ROOM

OFFICE 1OFFICE 2

1034

OFFICE

ANNEX

1014

METAL

OFFICE 11013

METAL

OFFICE 2

1004

NDI

OFFICE1035

10361037

1A REMOVE EXISTING PARTITION AND FURNITURE.

REMOVE EXISTING CARPET AND RUBBER WALL BASE.

STEP A: RENOVATE OFFICE ANNEX 1034

TEMPORARILY STORE EXISTING FURNITURE TO OTHER

LOCATION OF THE BUILDING FOR NEW CARPET

INSTALLATION PER CLIENT'S INSTRUCTION.

STEP A WORK

BOUNDARY

DEMOLISH POWER CONDUIT POLE PER ELEC AND RESTORE

ANY DAMAGED CEILING TILE DURING DEMOLITION.

REMOVE EXISTING PARTITION AND FURNITURE.

REMOVE EXISTING CARPET AND RUBBER WALL BASE.

STEP B: RENOVATE METAL OFFICES / NDI OFFICE 1013

TEMPORARILY STORE EXISTING WORK BENCH AND

MOVE TO NEW LAB (EXISTING METAL OFFICE, 1014 ).

1014 1004

2A

3A

1B

2B

3B

1A 1A

1A

1A

1A

1A

1A

1A

1A

1A

1A

2A

2A

2A

2A

2A

2A

2A

2A

2A

(NOT IN

CONTRACT)

3A

6A

3A

3A 3A

3A

1B 1B 1B 1B1B

2B2B

2B 2B

4B

4B1B

3B

REMOVE EXISTING DESKS / CUBICLES FROM LAB AREA.

STEP C: REMOVE EXISTING LAB FURNITURE/ WORK STATION

1C

1C 1C

1C

1C

STEP B

WORK BOUNDARY

1. THIS PROJECT INCLUDES RENOVATING EXISTING ANNEX OFFICE, METAL OFFICES AND NDI OFFICE OF THE

BUILDING 4032.

THE EXISTING FURNITURE AND PARTITIONS IN OPEN OFFICE AREA OF ANNEX OFFICE WILL BE REPLACED

WITH INCREASED NUMBER OF STANDARD WORKSTATIONS TO ACCOMMODATE EXISTING ADMIN

FUNCTION OF METAL OFFICES. THE EXISTING METAL OFFICE 1 WILL BE CONVERTED BACK TO LAB AREA.

THE METAL OFFICE 2 WILL BE RENOVATED TO LIBRARY SPACE. THE NEW WORK IS ALSO TO INCLUDE

RENOVATING NDI OFFICE INTO WHICH THE CURRENT 6 PERSONNEL ADMIN SPACES IN LAB AREA MOVE.

THE OVERALL WORK SCOPE INCLUDES NEW WORK STATIONS, RELOCATED FURNITURE, NEW FINISH

FLOORING AND NEW WALL PAINT AND ELECTRICAL CHANGE ACCORDING TO REVISED WORK STATION

AND OFFICE LAYOUT.

2. ELECTRICAL SCOPE IS TO INCLUDE RELOCATING NEW ELEC / COMM / DATA CONDUIT POLES IN

ACCORDANCE WITH THE NEW WORKSTATION LAYOUT.

4A

REMOVE EXISTING RUBBER STRIP.4A

5A

5A

5A TEMPORARILY REMOVE THRESHOLD FOR CARPET

INSTALLATION AND REUSE.

REMOVE EXISTING FLOORING VINYL SHEET. 4B5B 5B

5B

5B

REMOVE EXISTING TRANSITION STRIP. 5B

5A

1C

1C6B

TEMPORARILY STORE EXISTING CABINET AND MOVE TO

NEW LAB (EXISTING METAL OFFICE, 1014 ).

6B

6A REMOVE EXISTING CONFERENCE TABLE.

7A

7A REMOVE EXISTING WALL MOUNTED SHELVING.

2C

2C MOVE CONF. TABLE TO NEW LIBRARY (EXISTING METAL

OFFICE, 1013 ).

KEY PLANAREA OF WORK

F/N

: W

:\P

E-D

RA

WIN

GS

\ 21654A

_2-6

A-1

01.D

WG

(P

E-2

1654A

_2 A

-101)

1035 1036 1037

56'-03 8

"

38'-778

"

44'-0"

39'-0"

Page 3: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A

B

C

D

A

B

C

D

12345678

1235678

RE

NO

VA

TIO

N O

F B

LD

G. 4032

MC

AS

CH

ER

RY

PO

INT

, N

CR

EV

ISIO

N H

IST

OR

Y

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R E

AS

T

U.S

. M

AR

INE

CO

RP

S A

IR S

TA

TIO

N,

CH

ER

RY

PO

INT

, N

C

SHEET 3 OF 6

SCALE: 1/8" = 1'-0"

REV

SIZE

DCAGE CODE

96916

BUILDING 4032

MA

INT

EN

AN

CE

PLA

NN

ING

& S

US

TA

INM

EN

T D

IV D

WG

NO

RE

V

AP

PR

OV

ED

EN

VIR

FIR

E D

EP

T

OS

H

RE

VIE

WE

D

CH

EC

KE

D

DR

AW

N

DE

SIG

NE

R

ZO

NE

RE

VD

ES

CR

IPT

ION

DA

TE

WH

EN

PR

INT

ED

, IT

BE

CO

ME

S T

HE

US

ER

'S R

ES

PO

NS

IBIL

ITY

TO

DE

TE

RM

INE

CU

RR

EN

TN

ES

S O

F T

HIS

DR

AW

ING

. S

EE

RE

FE

RE

NC

E P

ED

QS

D-7

.3.7

-50

2.

4

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R

EA

ST

EF

FIC

IE

NS

A

GIL

IS

V

EL

OX

SEMPERFIDELIS

..

NEW WORK NOTES:

WO: XG27618

FRC-EAST

PE

-21654A

NE

W W

OR

K P

LA

N /

MA

TE

RIA

L A

ND

CO

LO

R S

CH

ED

UL

E

1A

STEP A: RENOVATE OFFICE ANNEX 1034

STEP B: RENOVATE METAL OFFICES AND NDI OFFICE 1013 1014

1014

2A

INSTALL NEW SHEET CARPET AND 6" RUBBER WALL BASE.

3A

PREPARE CLEAN AND SMOOTH WALL SURFACE AND APPLY NEW WALL PAINT.

TYP.

1A

1A

1A

1A

1A

1A

1A

1A

1A

(NOT IN

CONTRACT)

BREAK

ROOM

CONF.

ROOM

OFFICE 1 OFFICE 2

1034

OFFICE

ANNEX

1014

LAB

1013

1004

NDI

OFFICE

1035

1036 1037

LIBRARY

2A

2A

2A

2A2A

2A2A

2A

3A

3A

2A

1B

2B INSTALL NEW 2" RUBBER TRANSITION STRIP.

3B PREPARE CLEAN AND SMOOTH WALL SURFACE AND APPLY NEW WALL PAINT.

INSTALL NEW SHEET VINYL AND 6" RUBBER WALL BASE.

2B2B

5A

2B

3B

3B

3B

3B

3B

3B 3B

3B

3B 3B

3B

3B

3B

3B

3B

3B

4B

MATERIAL & COLOR SCHEDULE

WALL PAINT

RUBBER WALL BASE

ROPPE

PNNACLE DARK GRAY 6 INCH

OR APPROVED EQUAL

SHAW

CLASSIC 60756

OR APPROVED EQUAL

CARPET

COLOR: 50761

5B

RELOCATED WORK BENCH FROM NDI OFFICE

4B

4A

INSTALL NEW 2" RUBBER TRANSITION STRIP.

3A

NEW FILE

DRAWER(TYP.)

NEW

2'X4' DESK(TYP.)

INSTALL CARPET IN ACCORDANCE WITH THE CARPET

MANUFACTURER'S PRINTED INSTRUCTIONS AND THE

"CARPET AND RUG INSTITUTE"(CRI) STANDARD FOR

INSTALLATION OF COMMERCIAL TEXTILE COVERING

MATERIALS CRI-104.

PAINT APPLICATOR SHALL SATISFACTORILY APPLY

PAINT BY AIRLESS SPRAY OR BRUSH AT A MINIMUM

OF TWO COATINGS. MANUFACTURERS

SPECIFICATIONS SHALL GOVERN THE WORK.

4A

4A

REINSTALL EXISTING METAL THRESHOLD.

2A

2A

2A

2A

2A

2A

2A

2A

2A

2A

2A

2A2A

5A

6B

RELOCATED CONF. TABLE FROM EXISTING LIBRARY.

NEW

BOOKCASE(TYP.)

1B

1B 2B2B

INSTALL NEW SHEET CARPET AND 6" RUBBER WALL BASE.

5B

5B

5B

NEW CONF.

TABLE (NIC)

NEW WORK STATION

(TYP.)

SHEET VINYL

IVC CHARCOAL 695 RANDOM

LOW-GLOSS FINISH SHEET VINYL

OR APPROVED EQUALKEY PLAN AREA OF WORK

RUBBER TRANSITION STRIP

ROPPE

#67 ROLLING TRAFIC TRANSITION 3/8" TO 1/8"

COLOR: DARK GRAY (#150)

OR APPROVED EQUAL

SHERWIN-WILLIAMS

PROMAR 200 ZERO VOC INTERIOR LATEX

EG-SHEL B26-2600 SERIES

COLOR: FS 27780 (FEDERAL STANDARD)

OR APPROVED EQUAL

6B

1004

RELOCATED CABINET FROM ROOM 1013

F/N

: W

:\P

E-D

RA

WIN

GS

\ 21654A

_3-6

A-1

02.D

WG

(P

E-2

1654A

_3 A

-102)

1035 1036 1037

5A

Page 4: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A

B

C

D

A

B

C

D

12345678

1235678

RE

NO

VA

TIO

N O

F B

LD

G. 4032

MC

AS

CH

ER

RY

PO

INT

, N

CR

EV

ISIO

N H

IST

OR

Y

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R E

AS

T

U.S

. M

AR

INE

CO

RP

S A

IR S

TA

TIO

N,

CH

ER

RY

PO

INT

, N

C

SHEET 4 OF 6

SCALE: 1/8" = 1'-0"

REV

SIZE

DCAGE CODE

96916

BUILDING 4032

MA

INT

EN

AN

CE

PLA

NN

ING

& S

US

TA

INM

EN

T D

IV D

WG

NO

RE

V

AP

PR

OV

ED

EN

VIR

FIR

E D

EP

T

OS

H

RE

VIE

WE

D

CH

EC

KE

D

DR

AW

N

DE

SIG

NE

R

ZO

NE

RE

VD

ES

CR

IPT

ION

DA

TE

WH

EN

PR

INT

ED

, IT

BE

CO

ME

S T

HE

US

ER

'S R

ES

PO

NS

IBIL

ITY

TO

DE

TE

RM

INE

CU

RR

EN

TN

ES

S O

F T

HIS

DR

AW

ING

. S

EE

RE

FE

RE

NC

E P

ED

QS

D-7

.3.7

-50

2.

F/N

: W

:\P

E-D

RA

WIN

GS

\ P

E-2

16

54

P_

4-6

E-0

01

.DW

G (

PE

-21

65

4P

_4

E-0

01

)

4

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R

EA

ST

EF

FIC

IE

NS

A

GIL

IS

V

EL

OX

..

WO: XG27618

FRC-EAST

PE

-21654P

EL

EC

TR

ICA

L L

EG

EN

D, A

BB

RE

VIA

TIO

NS

& G

EN

ER

AL

NO

TE

S

G1. ALL WORK SHALL BE EXECUTED AND COMPLETED BY A QUALIFIED CONTRACTOR

HOLDING A CURRENT ELECTRICAL CONTRACTORS LICENSE ISSUED BY THE STATE OF

NORTH CAROLINA BOARD OF EXAMINERS OF ELECTRICAL CONTRACTORS, IN

ACCORDANCE WITH THE PROVISIONS AND REQUIREMENTS OF CHAPTER 87, ARTICLE 4,

OF THE GENERAL STATUTES OR THE STATE OF NORTH CAROLINA. THE LICENSE SHALL

BE APPROPRIATE FOR BOTH THE SYSTEM VOLTAGE AND THE ESTIMATED DOLLAR

VALUE OF THE CONTRACT BEING BID. THE CONTRACTOR SHALL ENSURE ALL

MATERIALS USED AND WORKMANSHIP PERFORMED ARE OF THE HIGHEST QUALITY AND

STANDARDS.

G2. ALL WORK SHALL BE COMPLETED IN STRICT COMPLIANCE WITH THE ARTICLES AND

REQUIREMENTS OF THE "NATIONAL ELECTRICAL CODE", NFPA-70, CURRENT EDITION,

AND THE "STANDARDS FOR ELECTRICAL SAFETY IN THE WORK PLACE", NFPA-70E,

CURRENT EDITION AND IN STRICT COMPLIANCE WITH THE REQUIREMENTS SET FORTH

IN THE CFR 910.330 OSHA "REGULATIONS FOR ELECTRICAL SAFETY".

G3. ALL SAFETY AND OCCUPATIONAL CODE REQUIREMENTS INCLUDING; ANSI A10.32

PERSONAL FALL PROTECTION, EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS, 29 CFR

1910 OCCUPATIONAL SAFETY AND HEALTH STANDARDS, 29 CFR 1926 SAFETY AND

HEALTH REGULATIONS FOR CONSTRUCTION, 29 CFR 1926.500 FALL PROTECTION, NFPA

70 NATIONAL ELECTRIC CODE, AND NFPA 70E STANDARD FOR ELECTRICAL SAFETY

REQUIREMENTS FOR EMPLOYEE WORKPLACES.

G4. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PROVIDING ALL THE

NECESSARY LABOR, MATERIALS, COMPONENTS, AND EQUIPMENT (SUITABLE AND

CORRECT FOR THE INSTALLATION APPLICATION), TO PROVIDE A FULLY FUNCTIONAL

AND OPERATIONAL ELECTRICAL SERVICE TO THE EQUIPMENT. THIS SHALL INCLUDE,

BUT NOT BE LIMITED TO, PROVIDING THE CORRECT SIZE AND TYPE DISCONNECT

ENCLOSURE WITH THE APPROPRIATE CIRCUIT BREAKER, (VOLT, AMPERES, MINIMUM

10kAIC SYMMETRICAL INTERRUPTING RATING). PLACARDS SHALL BE PROVIDED AND

INSTALLED AS PER THE DETAIL.

G5. NO NEW CONDUIT RUNS SHALL INTERFERE WITH ANY OPERATING SYSTEMS; TO

INCLUDE BUT NOT LIMITED TO ELECTRICAL POWER SYSTEMS, LIGHTING SYSTEMS,

MECHANICAL SYSTEMS, AND FIRE SUPPRESSION SYSTEMS.

G6. THE CONTRACTOR SHALL COORDINATE PRIOR TO BEGINNING ANY AND ALL WORK TO

BE PERFORMED WITH THE FRC EAST PLANT ENGINEERING BRANCH POC, SHOP

SUPERVISORS AND/OR AREA PERSONNEL, ALONG WITH ALL OTHER TRADES

INVOLVED/ASSOCIATED WITH THE PROJECT. ALL WORK SHALL BE PERFORMED IN A

MANNER AS TO CAUSE MINIMAL OR NO IMPACT ON PRODUCTION AND ANY/ALL

AFFECTED AREAS IN ADDITION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

DETERMINING AND COORDINATING WITH ALL TRADES/PARTIES INVOLVED, ANY AND ALL

WORK REQUIRED TO BE PERFORMED TO SUPPORT OTHER TRADES INVOLVED IN THIS

PROJECT EVEN THOUGH NOT SPECIFIED IN THE PROJECTS DRAWINGS AND/OR

DOCUMENT. SCHEDULE POWER OUTAGES 15 DAYS IN ADVANCE.

G7. IT IS HIGHLY RECOMMENDED THAT THE CONTRACTOR VISIT THE WORK SITE PRIOR TO

BID SUBMISSION TO DETERMINE THE EXTENT OF THE WORK, TO VERIFY ALL

DIMENSIONS AND TO DETERMINE THE AMOUNT OF MATERIAL REQUIRED. LACK OF

KNOWLEDGE OF EXISTING CONDITIONS SHALL NOT BE ACCEPTED AS JUSTIFICATION

FOR THE SUBMISSION BY THE CONTRACTOR OF ANY CHANGE ORDERS PERTAINING TO

THIS PROJECT.

G8. ALL MATERIAL SHALL BE NEW AND SHALL BE "UL LISTED" WHEN APPLICABLE.

G9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL

DEBRIS, TRASH AND EXCESS MATERIAL FROM THE WORK SITE AND SHALL ENSURE

THAT THE WORK SITE IS RETURNED TO A "BROOM CLEAN" CONDITION AT THE END OF

EACH WORK SHIFT.

G10. ALL CIRCUITS SHALL BE TYPE WRITTEN AND PROPERLY IDENTIFIED IN SOURCE

PANELBOARDS. PANELBOARD SCHEDULES SHALL BE PROVIDED AND UPDATED WITH

EVERY NEW INSTALLATION AND DEMOLITION. CIRCUITS THAT ARE REMOVED SHALL BE

IDENTIFIED AS "SPARE".

G11. THE CONTRACTOR SHALL PROVIDE AN IDENTIFICATION PLACARD FOR EACH

PANELBOARD, DISCONNECT SWITCH, AND ANY OTHER ADDITIONAL SPECIFIED

EQUIPMENT/ITEM. PLACARD DETAILS SHALL BE INCLUDED AS NEEDED IN THE DRAWING

PACKAGE.

G12. ALL DEVICE COVERPLATES SHALL HAVE CIRCUIT NUMBER AND SOURCE PANELBOARD

IDENTIFICATION LABELS "P-TOUCH" TYPE, NOT HAND WRITTEN. (i.e. P/W20, CKT #5)

G13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND/OR REPLACING AT

HIS/HER OWN EXPENSE. ANY AND ALL RESPECTED DAMAGES INCURRED AND/OR

ASSOCIATED WITH THE WORK OR ANY NEGLIGENT ACTIONS PERFORMED.

G14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY AND

DETERMINE THE MOST EFFICIENT ROUTING FOR ALL INSTALLED CONDUIT RUNS

BASED ON FIELD CONDITIONS FOUND DURING THE INSTALLATION. A PRE-BID VISIT TO

THE WORK-SITE, WHEN APPLICABLE, TO DETERMINE THE ROUTING AND QUANTITY OF

CONDUIT AND FITTINGS REQUIRED IS STRONGLY RECOMMENDED. CONDUIT ROUTING

SHOWN ON DRAWINGS ARE POINT TO POINT REFERENCES ONLY, UNLESS SPECIFIED

OTHERWISE, AND SHOULD NOT BE USED AS INSTALLATION DRAWINGS, OR FOR

ESTIMATING INSTALLATION COSTS. TYPICALLY CONDUIT SIZES AND TYPES SHALL BE

SPECIFIED FOR INSTALLATION.

G15. FOR ANY ADDITIONAL ELECTRICAL CLARIFICATIONS AND WHEN THE INSTALLATION IS

COMPLETE, CONTACT THE FRC EAST FACILITIES INFRASTRUCTURE PLANNING AND

ENGINEERING SUPPORT TEAM, CODE 6.3.1, ELORA MERRY, 252-464-8831 TO ATTEND

THE FINAL INSPECTION.

C1. A PRE-BID SIT VISIT TO DETERMINE THE ROUTING AND QUANTITY OF CONDUIT AND

FITTINGS REQUIRED IS STRONGLY RECOMMENDED. CONDUIT ROUTING SHOWN ON

FRC-EAST DRAWINGS ARE POINT TO POINT REFERENCES AND SHOULD NOT BE USED AS

CONSTRUCTION DRAWINGS, OR FOR ESTIMATING INSTALLATION COST.

C2. ALL INSTALLED CONDUIT RUNS SHALL COMPLY WITH THE REQUIREMENTS OF THE

NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION THAT ARE APPLICABLE TO THE

TYPE AND SIZE OF CONDUITS INSTALLATED.

C3. ONLY ELECTRICAL METALLIC TUBING (EMT), GALVANIZED RIGID CONDUIT (GRC) AND

LIQUID TIGHT FLEXIBLE METALLIC CONDUIT (LTC) ARE APPROVED FOR USE IN FRC-EAST

FOR ABOVE GRADE INSTALLATION. POLY VINYL CHLORIDE CONDUIT (PVC) SCHEDULE 40

IS APPROVED FOR USE IN FRC-EAST FOR BELOW GRADE INSTALLATION.

C4. ONLY STEEL THREADED OR STEEL COMPRESSION TYPE FITTINGS ARE PERMITTED FOR

USE WITH TYPE GRC AND EMT CONDUIT. THE USE OF SET SCREW AND DIE CAST ZINC

FITTINGS IS PROHIBITED. LTC CONDUIT SHALL USE FITTINGS RATED FOR THE CONDUIT

AND SHALL MAINTAIN THE LIQUID TIGHT INTEGRITY OF THE CONDUIT AFTER

INSTALLATION.

C5. CONDUIT BODIES, PULL BOXES, AND JUNCTION BOXES SHALL BE CAST IRON, CAST

ALUMINUM OR GALVANIZED SHEET METAL, EITHER STAMPED OR WELDED

CONSTRUCTION IS ACCEPTABLE. ALL BOXES AND FITTINGS SHALL BE PROPERLY SIZED

AND SHALL BE APPROPRIATE FOR THE INTENDED USE.

C6. BENDS MAY BE MACHINE FORMED IN THE FIELD OR FACTORY FORMED, BUT SHALL

COMPLY WITH THE BENDING RADIUS SET FORTH IN THE NATIONAL ELECTRICAL CODE,

NFPA-70, CURRENT EDITION, FOR THE SIZE AND TYPE OF CONDUIT BEING FORMED.

C7. ALL CONDUIT RUNS SHALL BE TERMINATED WITH AN APPROVED FITTING LOCKNUTS AND

SHALL BE BUSHED WITH AN APPROVED BUSHING. WHERE A CONDUIT RUN IS

TERMINATED OUTSIDE AN ENCLOSURE THE TERMINATION FITTING SHALL PROVIDE FOR

EACH CONDUCTOR TO BE INDIVIDUALLY BUSHED AT THE EXIT POINT.

W1. ALL BRANCH CIRCUIT WIRE SHALL BE COPPER, PROPERLY SIZED, AND OF THE

APPROPRIATE TYPE FOR THE INTENDED USE, AND APPLIED LOAD AS ESTABLISHED IN

THE NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION. ALL INSTALLED WIRING

SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75° C.

W2. WHEN CALCULATING THE APPROPRIATE WIRE SIZE FOR A CIRCUIT THE AMPACITY OF

THE CIRCUIT SHALL BE BASED ON THE LOWEST TEMPERATURE RATING OF ANY ONE

COMPONENT IN THE CIRCUIT. EXAMPLE: IF A WIRE IS RATED FOR 90° C BUT THE

CONNECTING TERMINALS ARE RATED FOR 75° C, THEN THE ENTIRE CIRCUIT SHALL BE

RATED FOR 75° C.

W3. THE MINIMUM SIZE WIRE PERMITTED FOR USE ON ANY POWER CIRCUIT IS #12 AWG

REGARDLESS OF THE ANTICIPATED AMPERAGE OF THE CIRCUIT. THE USE OF ANY

WIRING SMALLER THAN #12 AWG REQUIRES APPROVAL FROM THE PLANT ENGINEERING

BRANCH, (CODE 6.3.617) PRIOR TO INSTALLATION.

W4. ALL RECEPTACLES AND SWITCHES SHALL BE COMMERCIAL GRADE OR BETTER.

W5. NO CIRCUIT SHALL BE CONTINUED THROUGH A DEVICE. IF THE CIRCUIT IS TO CONTINUE

THEN THE DEVICE SHALL BE CONNECTED TO THE CIRCUIT USING A PIG TAIL BETWEEN

THE CIRCUIT AND THE DEVICE. DEVICES RATED AT ABOVE 30 AMPS SHALL BE

CONNECTED TO THE CIRCUIT ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS

AND SPECIFICATIONS.

W6. ALL WIRING USED ON MULTI-PHASE CIRCUITS SHALL BE COLOR CODES AS SPECIFIED IN

THE NATIONAL ELECTRICAL CODE, NFPA-70, CURRENT EDITION.

W7. ALL INSTALLED 120 VOLT SINGLE PHASE CIRCUITS SHALL HAVE A SEPARATE NEUTRAL

CONDUCTOR INSTALLED. NO SHARED NEUTRAL CONDUCTORS ARE PERMITTED.

W8. EACH CIRCUIT SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR IN THE CIRCUIT.

THE CONDUIT RUN SHALL NOT BE USED AS THE PRIMARY GROUND PATH FOR THE

CIRCUIT. ALL EQUIPMENT GROUNDS SHALL BE CLEARLY IDENTIFIED BY THE USE OF A

CONDUCTOR WITH INSULATION OR SHALL BE MARKED AT BOTH ENDS OF THE CIRCUIT

WITH AT LEAST THREE INCHES OF GREEN MARKING TAPE.

CONDUIT NOTES:GENERAL (ELECTRICAL) NOTES:

WIRE AND CABLE NOTES:

EXISTING TO REMAIN

EXISTING OR DEMOTION PLAN VIEW: TO BE REMOVED

NEW WORK PLAN VIEW: TO BE INSTALLED

20 AMP, 120 VOLT, DUPLEX RECEPTACLE

PANELBOARD

EXIT SIGN LIGHTING FIXTURE WITH BATTER PACK - CONNECT

AHEAD OF LOCAL SWITCH (EXISTING)

FIRE ALARM HORN/STROBE (EXISTING)

DATA NETWORK OUTLET, MOUNT 18" AFF, U.O.N. 4" SQUARE x

1-1/2" DEEP OUTLET BOX

ABOVE FINISHED FLOORAFF

ELECTRICAL METALLIC TUBINGEMT

TELEPHONE OUTLET, MOUNT 18" AFF, U.O.N. 4" SQUARE x 1-1/2"

DEEP OUTLET BOX

FIRE ALARM PULL STATION (EXISTING)F

TELE/DATA/POWER POLE

LEGEND AND ABBREVIATIONS

Page 5: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A

B

C

D

A

B

C

D

12345678

1235678

RE

NO

VA

TIO

N O

F B

LD

G. 4032

MC

AS

CH

ER

RY

PO

INT

, N

CR

EV

ISIO

N H

IST

OR

Y

FLE

ET

RE

AD

INE

SS

CE

NT

ER

EA

ST

U.S

. M

AR

INE

CO

RP

S A

IR S

TA

TIO

N, C

HE

RR

Y P

OIN

T, N

C

SHEET 5 OF 6

SCALE: 1/8" = 1'-0"

REV

SIZE

DCAGE CODE

96916

BUILDING 4032

MA

INT

EN

AN

CE

PLA

NN

ING

& S

US

TA

INM

EN

T D

IV D

WG

NO

RE

V

AP

PR

OV

ED

EN

VIR

FIR

E D

EP

T

OS

H

RE

VIE

WE

D

CH

EC

KE

D

DR

AW

N

DE

SIG

NE

R

ZO

NE

RE

VD

ES

CR

IPT

ION

DA

TE

WH

EN

PR

INT

ED

, IT

BE

CO

ME

S T

HE

US

ER

'S R

ES

PO

NS

IBIL

ITY

TO

DE

TE

RM

INE

CU

RR

EN

TN

ES

S O

F T

HIS

DR

AW

ING

. S

EE

RE

FE

RE

NC

E P

ED

QS

D-7

.3.7

-502.

4

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R

EA

ST

EF

FIC

IE

NS

A

GIL

IS

V

EL

OX

SEMPERFIDELIS

..

WO: XG27618

FRC-EAST

ELE

CT

RIC

AL D

EM

OLIT

ION

PLA

N

BREAK

ROOM

CONF.

ROOM

OFFICE 1OFFICE 2

1034

OFFICE

ANNEX

1014

METAL

OFFICE 11013

METAL

OFFICE 2

1004

NDI

OFFICE1035

10361037

(NOT IN

CONTRACT)

KEY PLAN AREA OF WORK

DEMOLITION WORK NOTES:

D1

D2

DEMOLISH EXISTING POWER POLES. DEMOLISH

ASSOCIATED SUPPORTS, WIRE AND CONDUIT BACK TO

EXISTING PANEL "PP1034". TURN BREAKERS OFF AND

UPDATE PANEL DIRECTORY WITH "SPARE".

EXISTING DATA DROP ASSOCIATED WITH THE

WORKBENCH TO BE RELOCATED. PROVIDE BLANK

COVER PLATE AT EXISTING DATA OUTLET LOCATION.

EXISTING ELECTRICAL TO REMAIN, UNLESS OTHERWISE

NOTED.

D2

D1

D1D1

D1

D1

D1

D3.

F/N

: W

:\P

E-D

RA

WIN

GS

\ P

E-2

1654P

_5-6

E-1

01.D

WG

(P

E-2

1654P

_5 E

-101)

PE

-21654P

Page 6: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A

B

C

D

A

B

C

D

12345678

1235678

RE

NO

VA

TIO

N O

F B

LD

G. 4032

MC

AS

CH

ER

RY

PO

INT

, N

CR

EV

ISIO

N H

IST

OR

Y

FLE

ET

RE

AD

INE

SS

CE

NT

ER

EA

ST

U.S

. M

AR

INE

CO

RP

S A

IR S

TA

TIO

N, C

HE

RR

Y P

OIN

T, N

C

SHEET 6 OF 6

SCALE: 1/8" = 1'-0"

REV

SIZE

DCAGE CODE

96916

BUILDING 4032

MA

INT

EN

AN

CE

PLA

NN

ING

& S

US

TA

INM

EN

T D

IV D

WG

NO

RE

V

AP

PR

OV

ED

EN

VIR

FIR

E D

EP

T

OS

H

RE

VIE

WE

D

CH

EC

KE

D

DR

AW

N

DE

SIG

NE

R

ZO

NE

RE

VD

ES

CR

IPT

ION

DA

TE

WH

EN

PR

INT

ED

, IT

BE

CO

ME

S T

HE

US

ER

'S R

ES

PO

NS

IBIL

ITY

TO

DE

TE

RM

INE

CU

RR

EN

TN

ES

S O

F T

HIS

DR

AW

ING

. S

EE

RE

FE

RE

NC

E P

ED

QS

D-7

.3.7

-502.

4

FL

EE

T R

EA

DIN

ES

S C

EN

TE

R

EA

ST

EF

FIC

IE

NS

A

GIL

IS

V

EL

OX

SEMPERFIDELIS

..

NEW WORK NOTES:

WO: XG27618

FRC-EAST

ELE

CT

RIC

AL N

EW

WO

RK

PLA

N

N1

N2

N3

N1 (NOT IN

CONTRACT)

BREAK

ROOM

CONF.

ROOM

OFFICE 1 OFFICE 2

1034

OFFICE

ANNEX

1014

LAB

1013

1004

NDI

OFFICE

1035

1036 1037

LIBRARY

KEY PLAN AREA OF WORK

N1

N1

UNLESS NOTED OTHERWISE, EXISTING ELECTRICAL

POWER, LIGHTING, AND FIRE ALARM TO REMAIN, NO

WORK REQUIRED.

REMOVED FROM SCOPE.

REUSE EXISTING SPARE 20 AMP, 1PH CIRCUIT BREAKERS

IN PANEL PRESENTLY RESERVED FOR THIS AREA.

PROVIDE AND INSTALL 6 #12 THHN & 2 #12 THHN GND, IN

3/4" EMT CONDUIT FROM PANELBOARD TO A JUNCTION

BOX LOCATED ABOVE THE DROP CEILING THE POWER

POLE LOCATION.

REUSE EXISTING SPARE 20 AMP, 1PH CIRCUIT BREAKERS

IN PANEL "PP1034" PRESENTLY RESERVED FOR THIS

AREA. PROVIDE AND INSTALL 2 #12 THHN & 1 #12 THHN

GND, IN 3/4" EMT CONDUIT FROM PANELBOARD TO NEW

RECEPTACLE LOCATION. VERIFY COLOR OF COVER

PLATES WITH CONTRACTING OFFICER PRIOR TO START

OF THIS WORK.

EXISTING TELEPHONE

BACKBOARD

N3

N3

N3

N4

N5

N6

RELOCATE EXISTING DATA DROP ASSOCIATED WITH THE

WORKBENCH BEING RELOCATED FROM THE NDI OFFICE

1004 TO THE LAB 1014. COORDINATE HEIGHT OF DROP

WITH CONTRACTING OFFICER PRIOR TO START OF THIS

WORK.

PROVIDE AND INSTALL EMPTY 3/4" EMT CONDUIT WITH

PULL STRING FROM EXISTING TELEPHONE ROOM TO NEW

TELE/DATA OUTLETS. COORDINATE LOCATIONS WITH

CONTRACTING OFFICER PRIOR TO START OF THIS WORK.

PROVIDE NEW TYPE WRITTEN PANEL DIRECTORY UPON

COMPLETION.

PROVIDE AND INSTALL NEW DEVICE COVERPLATES, AS

REQUIRED, TO MATCH EXISTING.

ALL NEW AND EXISTING DEVICE COVERPLATES SHALL

HAVE CIRCUIT NUMBER AND SOURCE PANELBOARD

IDENTIFICATION LABELS "P-TOUCH" TYPE, NOT HAND

WRITTEN. (I.E. R, CKT #30).

N4

N5

N6

N7

N8.

N9.

TELECOMMUNICATIONS

BACKBOARD

(EXISTING)

N3

TELE/DATA &

POWER POLE

3/4" EMT TO EACH DEVICE

1. TERMINATE EACH CONDUIT AT TOP OR BOTTOM EDGE OF

BACKBOARD WITH INSULATING BUSHING.

2. LEAVE 6' COIL OF PULL STRING AT BACKBOARD.

3. LEAVE 18" COIL OF PULL STRING AT EACH OUTLET.

TELECOMMUNICATION NOTES:

N7

N7

F/N

: W

:\P

E-D

RA

WIN

GS

\ P

E-2

1654P

_6-6

E-1

02.D

WG

(P

E-2

1654P

_6 E

-102)

PE

-21654P

Page 7: RENOVATION OF BLDG. 4032 MCAS CHERRY POINT, … · renovation of bldg. 4032 mcas cherry point, nc ... accordance with ufc 3-301-01 “structural engineering”, ... renovation of

A B C D

A B C D

12

34

56

78

12

35

67

8

RENOVATION OF BLDG. 4032MCAS CHERRY POINT, NC REVISION HISTORY

FLEET READINESS CENTER EAST

U.S. MARINE CORPS AIR STATION, CHERRY POINT, NCSH

EE

T 7

OF

7

SC

ALE

: 1/8

" = 1

'-0"

RE

V

SIZ

E

DC

AG

E C

OD

E

96

91

6

BU

ILD

ING

4032

MAINTENANCE PLANNING & SUSTAINMENT DIV DWG NO REV

APPROVED

ENVIR

FIRE DEPT

OSH

REVIEWED

CHECKED

DRAWN

DESIGNER

ZONE REV DESCRIPTION DATE

WHEN PRINTED, IT BECOMES THE USER'S RESPONSIBILITY TO DETERMINE

CURRENTNESS OF THIS DRAWING. SEE REFERENCE PEDQSD-7.3.7-502.

4

FLEET READINESS CENTER

EAST

EFFICIENS AGILIS VELOXSEMPER FIDELIS

. .

WO

: XG

27618

FR

C-E

AS

T

PE-21654A

NEW WORK PLAN / MATERIAL AND COLOR SCHEDULE

1034

OF

FIC

E

AN

NE

X

1014

LA

B

1013

1004

ND

I

OF

FIC

E

LIB

RA

RY

KE

Y P

LA

NA

RE

A O

F W

OR

K

F/N: W:\PE-DRAWINGS\ 21654A_3-6 A-102.DWG (PE-21654A_3 A-102)

PH

AS

E 1

PH

AS

E 2

PH

AS

E 2

PH

AS

E 2