1146 Central Ave. Albany, New York 12205 Phone: (518) 4530146 REPORT OF ASBESTOS AND PCB INSPECTION Performed For: HA2F Consultants in Engineering 1 Van Patten Drive Clifton Park, New York 12065 Location of Inspection: Junius Ponds and Clifton Springs NYS Thruway Service Plazas Material or Area Inspected: Service Plaza Roofs, Generator Building Roof (Clifton Springs) Asbestos Material Found: Junius Ponds – None Clifton Springs Generator Building – Flashing, tar on deck, window caulk PCBs Found: None NonAsbestos Materials Tested: Junius Ponds Service Plaza Perlite insulation, builtup roofing & flashing, parapet wall roofing, tar on deck, flashing cement, seam cement, door caulk, metal flashing caulk, cap block caulk Clifton Springs Service Plaza Perlite insulation, builtup roofing & flashing, parapet wall roll roofing, seam cement, tar on parapet wall, flashing cement, door caulk Clifton Springs Service Plaza – Generator Building Builtup roofing NonPCB Materials Tested: Junius Ponds Service Plaza Roof 1E door caulk Clifton Springs Service Plaza Roof 1D Door Caulk, roof insulation, generator building window caulk Date(s) of Inspection: July 26&27 and August 30, 2012 Project Number: 1213058A

Upload: others

Post on 05-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

1146 Central Ave. ● Albany, New York 12205 ● Phone: (518) 453‐0146 

REPORT OF ASBESTOS AND PCB INSPECTION  

Performed For:  HA2F Consultants in Engineering   1 Van Patten Drive   Clifton Park, New York 12065  

Location of   Inspection:  Junius Ponds and Clifton Springs NYS Thruway Service Plazas      

Material or   Area Inspected:  Service Plaza Roofs, Generator Building Roof (Clifton Springs)  

Asbestos Material Found:  Junius Ponds – None   Clifton Springs Generator Building – Flashing, tar on deck, window caulk  

PCBs Found:  None  

Non‐Asbestos Materials Tested:  Junius Ponds Service Plaza   Perlite  insulation,  built‐up  roofing &  flashing,  parapet wall  roofing,  tar  on 

deck,  flashing  cement,  seam  cement,  door  caulk, metal  flashing  caulk,  cap block caulk 

 

  Clifton Springs Service Plaza   Perlite insulation, built‐up roofing & flashing, parapet wall roll roofing, seam 

cement, tar on parapet wall, flashing cement, door caulk  

  Clifton Springs Service Plaza – Generator Building   Built‐up roofing  

Non‐PCB Materials Tested:  Junius Ponds Service Plaza   Roof 1E door caulk  

  Clifton Springs Service Plaza   Roof 1D Door Caulk, roof insulation, generator building window caulk  

Date(s) of Inspection:  July 26&27 and August 30, 2012  

Project Number:  12‐13058‐A     

Page 2: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

July 2012                       Junius Ponds and Clifton Springs Service Plazas NYS Thruway 

Page 2 of 5 1146 Central Ave. ● Albany, New York 12205 ● Phone: (518) 453‐0146 

Inspection By:  Alpine Environmental Services, Inc.   1146 Central Avenue   Albany, New York 12205   Phone (518) 453‐0146  

Inspector(s):  Paul Van Zandt: NYSDOL Cert.#AH95‐02581  

1.0 Asbestos Inspection  

1.1 Scope and Purpose  

This report  is  intended to document the pre‐renovation asbestos  inspection of the roofs of the above‐mentioned New York State service plazas.  The buildings are located within the Syracuse division of the New York State Thruway.   “Asbestos  containing materials”,  as  defined  by  the  United  States  Environmental  Protection  Agency (EPA), is any material containing greater than 1% by weight of asbestos.  Friable samples (samples easily crushed/pulverized by hand pressure), were  analyzed  via Polarized  Light Microscopy  (PLM)  and Non‐Friable  samples  (samples  not  easily  crushed/pulverized  by  hand  pressure),  were  analyzed  via Transmission Electron Microscopy (TEM) by EMSL Laboratory of New York, New York, a New York State Department of Health Approved Laboratory (ELAP #11506).  1.2 Description  Junius Ponds and Clifton Springs both had multiple roof areas to be  inspected.   All of the service plaza roofs were built‐up.  There was a generator building at the Clifton Springs service plaza.  The roof of the generator building at the Clifton Springs Service Plaza was completely covered with water at the time of the  initial  inspection and  therefore was not  sampled.   Roof Area 1D was not accessible at  the Clifton Springs Plaza at the time of inspection.  Alpine returned on August 30th and sampled the remaining roofs.  The generator building roof was PVC over built‐up roofing that was adhered to the concrete deck.  1.3 Limitations  Quantities of asbestos containing materials were estimated and the user must field verify all quantities.  The  atrium windows  of  the  Junius  Ponds  and Clifton  Springs  Plazas were  inaccessible  at  the  time of inspection.  

1.4 Results of Asbestos Inspection  Bulk samples were collected throughout the subject areas, as prescribed by US EPA ASHARA protocols for the number and types of samples.   

Page 3: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

July 2012                       Junius Ponds and Clifton Springs Service Plazas NYS Thruway 

Page 3 of 5 1146 Central Ave. ● Albany, New York 12205 ● Phone: (518) 453‐0146 

 The following asbestos containing materials were found at the following locations: 

 Building 

Location ACM 

(Sample #’s) Quantity  Substrate  Friability  Condition 

Clifton Springs 

Service Plaza 

Generator Building Roof 

Flashing (10‐01, 10‐02) 

32 sq. ft.  Concrete Non‐friable 

Good 

Tar on Deck (11‐01, 11‐02) 

240 sq. ft.  Concrete Non‐friable 

Good 

Generator Building 

Window Caulk (12‐01, 12‐02) 

8 sq. ft.  Brick Non‐friable 

Good 

Quantities are estimates only and should be field verified by the user.  

The following materials were sampled and determined not to contain asbestos: 

Building Non‐Asbestos 

Material Locations  Sample #’s 

Junius Ponds Service Plaza 

 

Built‐Up Roofing  Roof Areas #1A, 1B, 1C, 1D, 1E 

1‐01, 1‐02, 1‐03, 1‐04, 1‐05, 1‐06, 1‐07, 1‐08, 1‐09, 1‐10 

Flashing  Roof Area #1A, 1B, 1C, 1D, 1E 

2‐01, 2‐02, 2‐03, 2‐04, 2‐05, 2‐06, 2‐07, 2‐08, 2‐09, 2‐10 

Parapet Wall Roofing 

Roof 1E Parapet Wall  3‐01, 3‐02 

Tar on Deck  Roofs 1A, 1E 4‐01, 4‐02, 4‐03, 4‐04 

Flashing Cement  Roof 1C Pitch Pocket  5‐01, 5‐02 

Seam Cement  Roofs 1A, 1D, 1E 6‐01, 6‐02, 6‐03, 6‐04 

Door Caulk  Roof 1E  7‐01, 7‐02 Flashing Caulk  Roofs 1B, 1C Metal Flashing at Capblock  8‐01, 8‐02 Capblock Caulk  Roof 1B  9‐01, 9‐02 Perlite Insulation  Roofs 1A, 1E  10‐01, 10‐02 

Clifton Springs Service Plaza 

Built‐Up Roofing  Roofs 1A, 1B, 1C, 1D 

1‐01, 1‐02 1‐03, 1‐04 1‐05, 1‐06 3‐01, 3‐02* 

Flashing  Roofs 1A, 1B, 1C, 1D 

2‐01, 2‐02 2‐03, 2‐04 2‐05, 2‐06 4‐01, 4‐02* 

Parapet Wall Roofing 

Roof 1B, Roof 1D 3‐01, 3‐02 5‐01, 5‐02* 

Page 4: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

July 2012                       Junius Ponds and Clifton Springs Service Plazas NYS Thruway 

Page 4 of 5 1146 Central Ave. ● Albany, New York 12205 ● Phone: (518) 453‐0146 

Non‐Asbestos Materials Cont’d 

Building Non‐Asbestos 

Material Locations  Sample #’s 

Clifton Springs Service Plaza 

Cont’d 

Seam Cement Roof 1B on Parapet Wall,  Roof 1D on Parapet Wall 

4‐01, 4‐02 7‐01, 7‐02* 

Tar on Wall  Roof 1B Parapet Wall Under Roll Roofing  5‐01, 5‐02 

Flashing Cement Roof 1B at Scupper, Roof 1C at Pitch Pocket, 

Roof 1D at Scupper 6‐01, 6‐02 6‐01, 6‐02* 

Perlite Insulation  Roofs 1A, 1C  7‐01, 7‐02 Door Caulk  Roof 1D  8‐01, 8‐02* 

Clifton Springs Service Plaza Generator Building 

Built‐up Roofing  Generator Building Roof  9‐01, 9‐02* 

*Samples taken on August 30, 2012.  1.5 Conclusion & Recommendations  Any materials  not  sampled  during  this  inspection  should  be  considered  suspect  unless  sampled  and determined  to  be  non‐asbestos.    All  asbestos  containing  materials  must  be  abated  prior  to  the demolition/renovation of any of  the  structures unless performed under a variance  issued by  the NYS Department  of  Labor.    Disturbance/Abatement  of  any  asbestos  containing  materials,  as  well  as necessary air monitoring, must be performed by a NYS DOL licensed contractor, in accordance with state and federal regulations (NYS DOL ICR 56 and US EPA 40 CFR).  2.0 PCB Inspection:  2.1  Scope and Purpose  An inspection was performed of the subject structures for possible PCB containing items. This inspection included  only  the  sampling  of window  and  door  caulks  and  roofing  insulation  for  PCB  analysis.    The roofing insulation samples were made into a composite sample.    “PCBs”,  or  Polychlorinated  Biphenyls  contaminated  material,  as  defined  by  the  United  States Environmental  Protection Agency  (EPA),  is  any material  containing  greater  than  50ppm by weight of PCBs.   2.2 Conclusion  Polychlorinated Biphenyls (PCBs) 

Polychlorinated biphenyl  (PCB) oils were  commonly used as  thermal  insulating  fluids  in electrical and hydraulic  equipment  prior  to  a  (approximately)  1977 manufacture date.    Transformers  and  electrical ballasts are common places where PCB containing oils were used.  Polychlorinated Biphenyls  (PCBs) may be present  in  the caulk used  in windows, doorframes, masonry columns, and other masonry building materials  in many schools built or renovated between 1950 and 1978.  

Page 5: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

July 2012                       Junius Ponds and Clifton Springs Service Plazas NYS Thruway 

Page 5 of 5 1146 Central Ave. ● Albany, New York 12205 ● Phone: (518) 453‐0146 

PCB Caulking Sample Analysis The purpose of sampling was to determine the Polychlorinated Biphenyls (PCB) content of the caulking at the roof doors, roofing insulation and window caulk. 

 

Building  Sample Location  PCB Content 

(ppm) Junius Ponds Svc 

Plaza Roof Area #1E – Door Caulk  None detected 

Clifton Springs Roof Area #1D – Door Caulk  None detected 

Roof Area #1D – Roof Insulation Composite  None detected Generator Building – Window Caulk  None detected 

  If I can be of any further assistance to you on this, or any other matter, please do not hesitate to contact me (518) 453‐0146, ext. 314.    Sincerely, Alpine Environmental Services, Inc. 

 Paul Van Zandt NYS Dept. of Labor Asbestos Inspector Certificate # AH95‐02581  

Enclosures: Samples Results, Chains of Custodies, Company License, Personal Certifications, Laboratory Certifications 

Page 6: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

1-01031224199-0001

ROOF AREA #1A/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass7.0%

1-02031224199-0002

ROOF AREA #1A/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass5.3%

2-01031224199-0003

ROOF AREA #1A/ BOTTOM LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.9%

2-02031224199-0004

ROOF AREA #1A/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.9%

1-03031224199-0005

ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass7.2%

1-04031224199-0006

ROOF AREA #1B/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass6.6%

Page 1Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 7: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

2-03031224199-0007

ROOF AREA #1B - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass6.4%

2-04031224199-0008

ROOF AREA #1B - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass4.8%

1-05031224199-0009

ROOF AREA #1C/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.5%

1-06031224199-0010

ROOF AREA #1C/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.3%

2-05031224199-0011

ROOF AREA #1C/ BOTTOM LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass4.5%

2-06031224199-0012

ROOF AREA #1A/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.3%

1-07031224199-0013

ROOF AREA #1D/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass3.6%

Page 2Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 8: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

1-08031224199-0014

ROOF AREA #1D/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.2%

2-07031224199-0015

ROOF AREA #1D - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass7.4%

2-08031224199-0016

ROOF AREA #1D - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.1%

1-09031224199-0017

ROOF AREA #1E/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

1-10031224199-0018

ROOF AREA #1E/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.8%

2-09031224199-0019

ROOF AREA #1E - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass3.6%

2-10031224199-0020

ROOF AREA #1E/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.6%

Page 3Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 9: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

3-01031224199-0021

ROOF AREA #1E/ PARAPET WALL - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.8%

3-02031224199-0022

ROOF AREA # 1E PARAPET WALL - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

4-01031224199-0023

ROOF AREA #1A - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

4-02031224199-0024

ROOF AREA #1A - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

4-03031224199-0025

ROOF AREA #1E - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

4-04031224199-0026

ROOF AREA #1E - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.8%

5-01031224199-0027

ROOF AREA #1C/ AT PITCH POCKET - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Page 4Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 10: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

5-02031224199-0028

ROOF AREA #1C/ AT PITCH POCKET - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-01031224199-0029

ROOF AREA #1A/ ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-02031224199-0030

ROOF AREA #1D/ ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-03031224199-0031

ROOF AREA #1E - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-04031224199-0032

ROOF AREA #1E - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

7-01031224199-0033

ROOF AREA #1E - DOOR CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

White

White

7-02031224199-0034

ROOF AREA #1E - DOOR CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

White

White

Page 5Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 11: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224199CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 07/31/2012 9:47 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/2/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

8-01031224199-0035

ROOF AREA #1B/ METAL FLASHING AT CAPBLOCK - FLASH CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

8-02031224199-0036

ROOF AREA #1C/ METAL FLASHING AT CAPBLOCK - FLASH CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

9-01031224199-0037

ROOF AREA #1B - CAPBLOCK CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

9-02031224199-0038

ROOF AREA #1B - CAPBLOCK CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. The above test report relates only to the items tested. This test report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The results in this report meet all requirements of the NELAC Standards unless otherwise noted. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB's. Quantitative TEM is currently the only method that can be used to determine if a NOB material can be considered or treated as non-asbestos containing.

James Hall, Laboratory Manageror other approved signatory

Analyst(s)

NOB = Non Friable Organically Bound N/A = Not Applicable

Derrick Young

Steve Jusczuk

Samples analyzed by EMSL Analytical, Inc. New York, NY NYS ELAP 11506

Page 6THIS IS THE LAST PAGE OF THE REPORT.Test Report NY198w/A-7.21.0 Printed: 8/2/2012 7:16:49 PM

Initial Report From 08/02/2012 17:54:58

Page 12: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 13: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 14: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 15: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 16: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224225CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205Received: 07/31/12 9:46 AM

12-13058-A/ JUNIUS PONDS SERVICE PLAZA/ PHELPS, NY

Fax: (518) 453-0175Phone: (518) 453-0146

Project:

8/2/2012Analysis Date:7/26/2012Collected:

Sample Description Appearance % TypeAsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method

10-01031224225-0001

ROOF AREA #1A/ PERLITE INSULATION

Brown None DetectedFibrousHeterogeneous

Cellulose95.00% Non-fibrous (other)5.00%

10-02031224225-0002

ROOF AREA #1E/ PERLITE INSULATION

Brown None DetectedFibrousHeterogeneous

Cellulose95.00% Non-fibrous (other)5.00%

James Hall, Laboratory Manageror other approved signatory

Test Report PLMPTC-7.25.0 Printed: 8/2/2012 8:48:19 PM 1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.Samples analyzed by EMSL Analytical, Inc. New York, NY NYS ELAP 11506

Albert Grohmann (2)

Initial report from 08/02/2012 19:33:24

Page 17: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 18: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224340CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 08/01/2012 10:19 AM

12-13058-A/ CLIFTON SPRINGS SVC PLAZA/ CLIFTON SPRINGS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/3/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

1-01031224340-0001

ROOF AREA #1A/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass6.2%

1-02031224340-0002

ROOF AREA #1A/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

2-01031224340-0003

ROOF AREA #1A/ BOTTOM LAYER (UNDER INSULATION) - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

2-02031224340-0004

ROOF AREA #1A/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

1-03031224340-0005

ROOF AREA #1B - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass3.2%

1-04031224340-0006

ROOF AREA #1B - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass4.4%

2-03031224340-0007

ROOF AREA #1B/ BOTTOM LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass<1%

Page 1Test Report NY198w/A-7.21.0 Printed: 8/3/2012 4:19:50 PM

Initial Report From 08/03/2012 16:19:50

Page 19: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224340CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 08/01/2012 10:19 AM

12-13058-A/ CLIFTON SPRINGS SVC PLAZA/ CLIFTON SPRINGS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/3/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

2-04031224340-0008

ROOF AREA #1B/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass2.7%

1-05031224340-0009

ROOF AREA #1C/ BOTTOM LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass5.6%

1-06031224340-0010

ROOF AREA #1C/ TOP LAYER - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass3.3%

2-05031224340-0011

ROOF AREA #1C/ BOTTOM LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass4.6%

2-06031224340-0012

ROOF AREA #1C/ TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.2%

3-01031224340-0013

ROOF AREA #1B/ ON PARAPET WALL - ROLL ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass1.0%

Page 2Test Report NY198w/A-7.21.0 Printed: 8/3/2012 4:19:50 PM

Initial Report From 08/03/2012 16:19:50

Page 20: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224340CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 08/01/2012 10:19 AM

12-13058-A/ CLIFTON SPRINGS SVC PLAZA/ CLIFTON SPRINGS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/3/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

3-02031224340-0014

ROOF AREA #1B/ ON PARAPET WALL - ROLL ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Glass6.9%

4-01031224340-0015

ROOF AREA #1B/ ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

4-02031224340-0016

ROOF AREA #1B/ ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

5-01031224340-0017

ROOF AREA #1B/ ON PARAPET WALL UNDER ROLL - TAR ON WALL

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

5-02031224340-0018

ROOF AREA #1B/ ON PARAPET WALL UNDER ROLL - TAR ON WALL

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-01031224340-0019

ROOF AREA #1B/ AT SCUPPER - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Page 3Test Report NY198w/A-7.21.0 Printed: 8/3/2012 4:19:50 PM

Initial Report From 08/03/2012 16:19:50

Page 21: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224340CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 08/01/2012 10:19 AM

12-13058-A/ CLIFTON SPRINGS SVC PLAZA/ CLIFTON SPRINGS, NYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

8/3/2012Analysis Date:

Collected: 7/26/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

6-02031224340-0020

ROOF AREA #1C/ AT PITCH POCKET - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

8/2/2012

8/3/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. The above test report relates only to the items tested. This test report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The results in this report meet all requirements of the NELAC Standards unless otherwise noted. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB's. Quantitative TEM is currently the only method that can be used to determine if a NOB material can be considered or treated as non-asbestos containing.

James Hall, Laboratory Manageror other approved signatory

Analyst(s)

NOB = Non Friable Organically Bound N/A = Not Applicable

Derrick Young

Steve Jusczuk

Samples analyzed by EMSL Analytical, Inc. New York, NY NYS ELAP 11506

Page 4THIS IS THE LAST PAGE OF THE REPORT.Test Report NY198w/A-7.21.0 Printed: 8/3/2012 4:19:50 PM

Initial Report From 08/03/2012 16:19:50

Page 22: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 23: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 24: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031224350CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205Received: 08/01/12 10:11 AM

12-13058-A/ CLIFTON SPRINGS SVC PLAZA/ CLIFTON SPRINGS, NY

Fax: (518) 453-0175Phone: (518) 453-0146

Project:

8/2/2012Analysis Date:7/26/2012Collected:

Sample Description Appearance % TypeAsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method

7-01031224350-0001

ROOF AREA #1A - PERLITE INSULATION

Brown None DetectedNon-FibrousHeterogeneous

Cellulose65.00% Non-fibrous (other)35.00%

7-02031224350-0002

ROOF AREA #1C - PERLITE INSULATION

Brown None DetectedFibrousHomogeneous

Cellulose55.00% Non-fibrous (other)20.00%Perlite25.00%

James Hall, Laboratory Manageror other approved signatory

Test Report PLMPTC-7.25.0 Printed: 8/2/2012 10:33:36 PM 1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.Samples analyzed by EMSL Analytical, Inc. New York, NY NYS ELAP 11506

Emily Myint (1)Kamel Alawawda (1)

Initial report from 08/02/2012 22:07:10

Page 25: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 26: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

Analytical Sample Results

Job Number: 12080151Fax: 518.381.6055Phone: 518.346.4592Schenectady, NY 123082190 Technology DrivePace Analytical Services, Inc.

Client Sample ID:Sample Matrix:Received Date:

Collection Date:

1-ROOF 1E DOOR CAULKCAULK

08/08/2012 17:47

07/26/2012

Lab Sample ID: 12080151-01 (AP23287)

ALPINE ENVIRONMENTAL SERVICES, INCClient:

Batch ID AnalystDate Init Wt./Vol.Method Final Vol. ColumnGC20F-1354-52 SW-846 8082 (PCB) JKA08/14/2012 23:33 NAAnalysis 1: NA Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

19424 EPA 3540C JWO08/13/2012 15:31 1.02 gPrep 1: 25.0 mL NA

N/APercent Solid:

JUNIUS PONDS SERVICE STN WARNERS NY 12-13058-AProject:

Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File IDNDAroclor 1016 0.488 1.00 GC20F-1354-52U12674-11-2NDAroclor 1221 0.488 1.00 GC20F-1354-52U11104-28-2NDAroclor 1232 0.488 1.00 GC20F-1354-52U11141-16-5NDAroclor 1242 0.488 1.00 GC20F-1354-52U53469-21-9NDAroclor 1248 0.488 1.00 GC20F-1354-52U12672-29-6NDAroclor 1254 0.488 1.00 GC20F-1354-52U11097-69-1NDAroclor 1260 0.488 1.00 GC20F-1354-52U11096-82-5NDAroclor 1262 0.488 1.00 GC20F-1354-52U37324-23-5NDAroclor 1268 0.488 1.00 GC20F-1354-52U11100-14-4NDTotal PCB Amount > RL 1.00 GC20F-1354-52U1336-36-3

SurrogateLimits

Q File ID% RecoveryCAS No.1

(%)Tetrachloro-meta-xylene 95.8 60.0-140 GC20F-1354-52877-09-8Decachlorobiphenyl 104 60.0-140 GC20F-1354-522051-24-3Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. 1

ND: Denotes analyte not detected at a concentration greater than the PQL.PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample.

2190 Technology Drive | Schenectady, NY 12308 | Phone 518.346.4592 | Fax 518.381.6055 | www.pacelabs.comThis report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc.

4

Pace Analytical Services, Inc. 12080151 Page 11 of 14

Page 27: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

3

Pace Analytical Services, Inc. 12080151 Page 9 of 14

Page 28: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228043CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:57 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA/ NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/1/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

1-01031228043-0001

ROOF/ AREA 1D AT ROOF CORE - PERLITE INSULATION

PLM NYS 198.1 Friable 9/1/2012

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

Not Analyzed

Not Analyzed

N/A

N/A

None DetectedBrown 25%Cellulose75.00%

1-02031228043-0002

ROOF/ AREA 1D AT FLASH CORE - PERLITE INSULATION

PLM NYS 198.1 Friable 9/2/2012

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

Not Analyzed

Not Analyzed

N/A

N/A

None DetectedBrown 60%Cellulose40.00%

2-01031228043-0003

GENERATOR BUILDING ROOF AT ROOF CORE - CONCRETE DECK

PLM NYS 198.1 Friable 9/1/2012

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

Not Analyzed

Not Analyzed

N/A

N/A

None DetectedGray/Black 100%

2-02031228043-0004

GENERATOR BUILDING ROOF AT FLASH CORE - CONCRETE DECL

PLM NYS 198.1 Friable 9/2/2012

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

Not Analyzed

Not Analyzed

N/A

N/A

None DetectedGray/Black 100%

Page 1Test Report NY198w/A-7.21.0 Printed: 9/2/2012 5:42:38 AM

Initial Report From 09/02/2012 05:41:46

Page 29: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228043CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:57 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA/ NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/1/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. The above test report relates only to the items tested. This test report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The results in this report meet all requirements of the NELAC Standards unless otherwise noted. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB's. Quantitative TEM is currently the only method that can be used to determine if a NOB material can be considered or treated as non-asbestos containing.

James Hall, Laboratory Manageror other approved signatory

Analyst(s)

NOB = Non Friable Organically Bound N/A = Not Applicable

Steve Jusczuk

Sean Scales

Page 2THIS IS THE LAST PAGE OF THE REPORT.Test Report NY198w/A-7.21.0 Printed: 9/2/2012 5:42:38 AM

Initial Report From 09/02/2012 05:41:46

Page 30: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 31: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228041CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:56 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/4/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

3-01031228041-0001

ROOF AREA 1D - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

3-02031228041-0002

ROOF AREA 1D - BUILT-UP ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

4-01031228041-0003

ROOF AREA 1D - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

4-02031228041-0004

ROOF AREA 1D - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Brown

Brown

5-01031228041-0005

ROOF AREA 1D ON PARAPET WALL - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

5-02031228041-0006

ROOF AREA 1D ON PARAPET WALL - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

6-01031228041-0007

ROOF AREA 1D AT SCUPPER - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Page 1Test Report NY198w/A-7.21.0 Printed: 9/4/2012 7:02:11 PM

Report Amended 09/04/2012 18:52:57 Replaces Report Amended 09/02/2012 12:59:56. Reason Code: Data Entry-Samples Added

Page 32: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228041CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:56 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/4/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

6-02031228041-0008

ROOF AREA 1D AT SCUPPER - FLASHING CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

7-01031228041-0009

ROOF AREA 1D ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

7-02031228041-0010

ROOF AREA 1D ON PARAPET WALL - SEAM CEMENT

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

8-01031228041-0011

ROOF AREA 1D - DOOR CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Clear

Clear

8-02031228041-0012

ROOF AREA 1D - DOOR CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Clear

Clear

9-01031228041-0013

GENERATOR BUILDING BOTTOM LAYER - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

9-02031228041-0014

GENERATOR BUILDING TOP LAYER - ROOFING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

Page 2Test Report NY198w/A-7.21.0 Printed: 9/4/2012 7:02:11 PM

Report Amended 09/04/2012 18:52:57 Replaces Report Amended 09/02/2012 12:59:56. Reason Code: Data Entry-Samples Added

Page 33: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228041CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:56 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/4/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

10-01031228041-0015

GENERATOR BUILDING BOTTOM LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A Positive Stop (Not Analyzed)

Black

Black

6.0% Chrysotile

6.0% Total

10-02031228041-0016

GENERATOR BUILDING TOP LAYER - FLASHING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Positive Stop (Not Analyzed)

Positive Stop (Not Analyzed)

11-01031228041-0017

GENERATOR BUILDING AT ROOF CORE - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A Positive Stop (Not Analyzed)

Black

Black

8.2% Chrysotile

8.2% Total

11-02031228041-0018

GENERATOR BUILDING AT FLASH CORE - TAR ON DECK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Positive Stop (Not Analyzed)

Positive Stop (Not Analyzed)

12-01031228041-0019

GENERATOR BUILDING REAR WINDOW - WINDOW CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A Positive Stop (Not Analyzed)

Gray

Gray

5.0% Chrysotile

5.0% Total

12-02031228041-0020

GENERATOR BUILDING SIDE WINDOW - WINDOW CAULK

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

9/4/2012

9/2/2012

Not Analyzed

N/A

N/A

Positive Stop (Not Analyzed)

Positive Stop (Not Analyzed)

Page 3Test Report NY198w/A-7.21.0 Printed: 9/4/2012 7:02:11 PM

Report Amended 09/04/2012 18:52:57 Replaces Report Amended 09/02/2012 12:59:56. Reason Code: Data Entry-Samples Added

Page 34: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

EMSL Analytical, Inc.307 West 38th Street, New York, NY 10018Phone/Fax: (212) 290-0051 / (212) 290-0058http://www.emsl.com [email protected]

031228041CustomerID: ALPI50CustomerPO:ProjectID:

EMSL Order:

Attn: Alpine Environmental Services1146 Central Avenue

Albany, NY 12205 Received: 09/01/2012 8:56 AM

12-13058-A/ CLIFTON SPRINGS SERVICE AREA NYS THRUWAYFax: (518) 453-0175

Phone: (518) 453-0146 Project:

9/4/2012Analysis Date:

Collected: 8/30/2012

AnalyzedDate Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. The above test report relates only to the items tested. This test report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The results in this report meet all requirements of the NELAC Standards unless otherwise noted. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB's. Quantitative TEM is currently the only method that can be used to determine if a NOB material can be considered or treated as non-asbestos containing.

James Hall, Laboratory Manageror other approved signatory

Analyst(s)

NOB = Non Friable Organically Bound N/A = Not Applicable

Daena Charles

Robert Georgens

Samples analyzed by EMSL Analytical, Inc. New York, NY NYS ELAP 11506

Page 4THIS IS THE LAST PAGE OF THE REPORT.Test Report NY198w/A-7.21.0 Printed: 9/4/2012 7:02:11 PM

Report Amended 09/04/2012 18:52:57 Replaces Report Amended 09/02/2012 12:59:56. Reason Code: Data Entry-Samples Added

Page 35: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 36: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 37: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 38: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

Analytical Sample Results

Job Number: 12080562Fax: 518.381.6055Phone: 518.346.4592Schenectady, NY 123082190 Technology DrivePace Analytical Services, Inc.

Client Sample ID:Sample Matrix:Received Date:

Collection Date:

1-ROOF AREA 1D DOOR CAULKCAULK

08/31/2012 10:40

08/30/2012 08:00

Lab Sample ID: 12080562-01 (AP26331)

ALPINE ENVIRONMENTAL SERVICES, INCClient:

Batch ID AnalystDate Init Wt./Vol.Method Final Vol. ColumnGC20F-1379-40 SW-846 8082 (PCB) JKA09/06/2012 22:08 NAAnalysis 1: NA Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

19745 EPA 3540C DKA09/04/2012 10:00 1.05 gPrep 1: 25.0 mL NA

N/APercent Solid:

CLIFTON SPRINGS SERVICE AREA NYS THRUWAYProject:

Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File IDNDAroclor 1016 0.478 1.00 GC20F-1379-40U12674-11-2NDAroclor 1221 0.478 1.00 GC20F-1379-40U11104-28-2NDAroclor 1232 0.478 1.00 GC20F-1379-40U11141-16-5NDAroclor 1242 0.478 1.00 GC20F-1379-40U53469-21-9NDAroclor 1248 0.478 1.00 GC20F-1379-40U12672-29-6NDAroclor 1254 0.478 1.00 GC20F-1379-40U11097-69-1NDAroclor 1260 0.478 1.00 GC20F-1379-40U11096-82-5NDAroclor 1262 0.478 1.00 GC20F-1379-40U37324-23-5NDAroclor 1268 0.478 1.00 GC20F-1379-40U11100-14-4NDTotal PCB Amount > RL 1.00 GC20F-1379-40U1336-36-3

SurrogateLimits

Q File ID% RecoveryCAS No.1

(%)Tetrachloro-meta-xylene 93.7 60.0-140 GC20F-1379-40877-09-8Decachlorobiphenyl 108 60.0-140 GC20F-1379-402051-24-3Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. 1

ND: Denotes analyte not detected at a concentration greater than the PQL.PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample.

2190 Technology Drive | Schenectady, NY 12308 | Phone 518.346.4592 | Fax 518.381.6055 | www.pacelabs.comThis report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc.

Page 39: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

Analytical Sample Results

Job Number: 12080562Fax: 518.381.6055Phone: 518.346.4592Schenectady, NY 123082190 Technology DrivePace Analytical Services, Inc.

Client Sample ID:Sample Matrix:Received Date:

Collection Date:

2-GENERATOR BUILDING WINDOW CAULKCAULK

08/31/2012 10:40

08/30/2012 08:00

Lab Sample ID: 12080562-02 (AP26332)

ALPINE ENVIRONMENTAL SERVICES, INCClient:

Batch ID AnalystDate Init Wt./Vol.Method Final Vol. ColumnGC20F-1379-41 SW-846 8082 (PCB) JKA09/06/2012 22:20 NAAnalysis 1: NA Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

19745 EPA 3540C DKA09/04/2012 10:00 1.42 gPrep 1: 25.0 mL NA

N/APercent Solid:

CLIFTON SPRINGS SERVICE AREA NYS THRUWAYProject:

Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File IDNDAroclor 1016 0.351 1.00 GC20F-1379-41U12674-11-2NDAroclor 1221 0.351 1.00 GC20F-1379-41U11104-28-2NDAroclor 1232 0.351 1.00 GC20F-1379-41U11141-16-5NDAroclor 1242 0.351 1.00 GC20F-1379-41U53469-21-9NDAroclor 1248 0.351 1.00 GC20F-1379-41U12672-29-6NDAroclor 1254 0.351 1.00 GC20F-1379-41U11097-69-1NDAroclor 1260 0.351 1.00 GC20F-1379-41U11096-82-5NDAroclor 1262 0.351 1.00 GC20F-1379-41U37324-23-5NDAroclor 1268 0.351 1.00 GC20F-1379-41U11100-14-4NDTotal PCB Amount > RL 1.00 GC20F-1379-41U1336-36-3

SurrogateLimits

Q File ID% RecoveryCAS No.1

(%)Tetrachloro-meta-xylene 90.7 60.0-140 GC20F-1379-41877-09-8Decachlorobiphenyl 106 60.0-140 GC20F-1379-412051-24-3Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. 1

ND: Denotes analyte not detected at a concentration greater than the PQL.PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample.

2190 Technology Drive | Schenectady, NY 12308 | Phone 518.346.4592 | Fax 518.381.6055 | www.pacelabs.comThis report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc.

Page 40: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING

Analytical Sample Results

Job Number: 12080562Fax: 518.381.6055Phone: 518.346.4592Schenectady, NY 123082190 Technology DrivePace Analytical Services, Inc.

Client Sample ID:Sample Matrix:Received Date:

Collection Date:

ROOF INSULATIONSOLID

08/31/2012 10:40

08/30/2012 08:00

Lab Sample ID: 12080562-07 (AP26337)

ALPINE ENVIRONMENTAL SERVICES, INCClient:

Batch ID AnalystDate Init Wt./Vol.Method Final Vol. ColumnGC20F-1378-22 SW-846 8082 (PCB) JES09/05/2012 13:47 NAAnalysis 1: NA Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

19752 EPA 3540C TJH09/04/2012 09:35 2.00 gPrep 1: 25.0 mL NA

100 - Results are based on dry weight unless otherwise noted.Percent Solid:

CLIFTON SPRINGS SERVICE AREA NYS THRUWAYProject:

Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File IDNDAroclor 1016 0.250 1.00 GC20F-1378-22U12674-11-2NDAroclor 1221 0.250 1.00 GC20F-1378-22U11104-28-2NDAroclor 1232 0.250 1.00 GC20F-1378-22U11141-16-5NDAroclor 1242 0.250 1.00 GC20F-1378-22U53469-21-9NDAroclor 1248 0.250 1.00 GC20F-1378-22U12672-29-6NDAroclor 1254 0.250 1.00 GC20F-1378-22U11097-69-1NDAroclor 1260 0.250 1.00 GC20F-1378-22U11096-82-5NDAroclor 1262 0.250 1.00 GC20F-1378-22U37324-23-5NDAroclor 1268 0.250 1.00 GC20F-1378-22U11100-14-4NDTotal PCB Amount > RL 1.00 GC20F-1378-22U1336-36-3

SurrogateLimits

Q File ID% RecoveryCAS No.1

(%)Tetrachloro-meta-xylene 91.0 60.0-140 GC20F-1378-22877-09-8Decachlorobiphenyl 104 60.0-140 GC20F-1378-222051-24-3Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. 1

ND: Denotes analyte not detected at a concentration greater than the PQL.PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample.

2190 Technology Drive | Schenectady, NY 12308 | Phone 518.346.4592 | Fax 518.381.6055 | www.pacelabs.comThis report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc.

Page 41: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING
Page 42: REPORT OF ASBESTOS AND PCB INSPECTION · N/A N/A Inconclusive: None Detected None Detected Black Black 2.9% Glass 1-03 031224199-0005 ROOF AREA #1B/ BOTTOM LAYER - BUILT-UP ROOFING