![Page 1: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/1.jpg)
Requirements for Bias, Low Voltage and Control Signal Distribution
Theresa [email protected]
21 April 2016
Single Phase ProtoDUNEWarm Interface Board Working Meeting
4/21/20161
![Page 2: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/2.jpg)
Cable Requirements
Important Aspects of Cables and Connectors• Must conform to Grounding/Shielding Plan
– Review by Grounding/Shielding Committee
• Must conform to Safety Standards– Cables and Connectors should be rated/tested for conditions
• Cold Cables should be tested in Materials Test Stand
• Other aspects– Cable strain relief
– Mechanical fit
– “Easy” to Install
– Robustness
4/21/20162
![Page 3: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/3.jpg)
Shielding Cable Penetrations
4/21/20163
![Page 4: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/4.jpg)
ProtoDUNE Infrastructure Grounding
Documentation gathered in dune docdb 879
4/21/20164
![Page 5: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/5.jpg)
4/21/20165
![Page 6: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/6.jpg)
ProtoDUNE Grounding
4/21/20166
![Page 7: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/7.jpg)
ProtoDUNE Grounding Points
4/21/20167
![Page 8: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/8.jpg)
List of Cables which Penetrate Cryostat
APA Readout (6 APAs in ProtoDUNE)• 20 FE Signal/Control Cables• 20 FE Power Cables• 10 PD Readout Cables
Other• Wire Bias Cables (HV)• Drift HV• Camera System
• Calibration systems
• Purity Monitors
4/21/20168
![Page 9: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/9.jpg)
Cold FE Board Cables
Each FE Board will require two cables• Signal/Control Cable
– 12 Differential Signal Pairs• Will carry high speed data and control signals
• Power Cable– Will carry power to FE Analog Mother Board and FPGA Mezzanine
• 14 wire (7 Voltage/Return Pairs)
• 20 AWG
4/21/20169
![Page 10: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/10.jpg)
Current Design
10
Input connectors on the back of the box (straight connector from the FEM).
Bottom edge of the box leak tight to trap and divert boil off gas
Box opening in line with the data cable to minimize cable bending
Right angle power connector to reduce box thickness
Plugged in
BNL
![Page 11: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/11.jpg)
4/21/201611
BNL
Carries Data/Control
![Page 12: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/12.jpg)
Low Voltage Cable
4/21/201612
BNL – From Matt
![Page 13: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/13.jpg)
Photon Detector Cables
Plan for ProtoDUNE• Use multi‐conductor twisted pair with individual shield,
Teflon jacket, CAT6A • The cable has 4 twisted pairs in one jacket • Plan to read out gang of 3 SiPM
4/21/201613
![Page 14: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/14.jpg)
4/21/201614
![Page 15: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/15.jpg)
A Combined TPC + PD Nozzle
14” CF flange for the cold electronics and bias cables from TWO APAs
10” CF flange for the PD cables from TWO APAs plus 4 DB15 connectors
10” pipe, 12” CF flange for the cryostat nozzle
Lifting the field cage panels through these ports remains possibility.
15
BNL
![Page 16: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/16.jpg)
Integrated Cable Strain Relief and Baffle
Simple baffle plate to create local high velocity purging flow
16
Baffle plug pushed into the crossing tube to create high velocity gas flow over extended distance
BNL
![Page 17: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/17.jpg)
CE Signal Feedthrough Flange Construction
The flange is constructed from a standard 14” CF flange, sliced into two halves, with a PCB glued in between.
The PCB has 40 power connectors and 40 data connectors on the cold side. On the warm side, 10 edge connectors supply the power, and 10 connectors link the data lines.
12 SHV ceramic feedthroughs are welded on the flange. They provide the bias voltages for the wire planes and the electron diverters.
The ribs on the flange keep the deformation of the PCB due to cryostat pressure minimal.
17
BNL
![Page 18: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/18.jpg)
High Voltage
4/21/201618
![Page 19: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/19.jpg)
APA Bias Schematic Diagram
19
BNL – From Bo Yu
Wire Bias
![Page 20: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/20.jpg)
Wire Bias Cables
Wire Bias Cables• SHV connectors
• HV filter should be incorporated on APA CR Boards
• At feedthrough port we want to follow grounding/shielding guidelines
4/21/201620
![Page 21: Requirements for Bias, Low Voltage and Control Signal ... › ... › tms_cables_APR2016_v1.pdf · 21 April 2016. Single Phase ProtoDUNE. Warm Interface Board Working Meeting. 1 4/21/2016](https://reader033.vdocument.in/reader033/viewer/2022060510/5f26469a7261c24a3469a877/html5/thumbnails/21.jpg)
HV System Schematic Diagram
21
BNL – From Bo Yu
HV Cable