residential & commercial · 2020-03-28 · 3 air conditioning residential & commercial 9...
TRANSCRIPT
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW BE 0412 120 336
RPR Oostende
w w w . d a i k i n a f r i c a . c o m
H e a t i n g a n d A i r C o n d i t i o n i n g S y s t e m s
R E S I D E N T I A L & C O M M E R C I A L C ATA L O G U E 2 0 0 8
ÉEPCEN08-023&ËÍ
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. participates in the Eurovent Certifi cation Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certifi ed data of certifi ed models are listed in the Eurovent Directory. Multi units are Eurovent certifi ed for combinations up to 2 indoor units.
The present catalogue is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fi tness for particular purpose of its content and the products and services presented therein. Specifi cations are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin Europe N.V..
Daikin products are distributed by:
EPCE
N08
-023
• 0
8/20
08 •
Cop
yrig
ht ©
Dai
kin
Prin
ted
in B
elgi
um b
y La
nnoo
(ww
w.la
nnoo
prin
t.be
), a
com
pany
who
se c
once
rn
for
the
envi
ronm
ent
is s
et in
the
EM
AS
and
ISO
140
01 s
yste
ms.
Resp
onsi
ble
edito
r: D
aiki
n Eu
rope
N.V
., Za
ndvo
orde
stra
at 3
00, B
-840
0 O
oste
nde
Resid
ential &
Co
mm
ercial CA
TA
LO
GU
E 2
00
8
W W W. D A I K I N A F R I C A . C O M
Daikin Airconditioning Poland Sp.z o.o.
Daikin Airconditioning Germany Gmbh.Daikin Airconditioning Central EuropeHandelsgmbH.
Daikin Central Europe Czech Republic Spol.s.ro
Daikin Airconditioning Italy SpA
Daikin Europe Middle East Office
Daikin Magyarország Klimatechnikai Kft.
Daikin Airconditioning Greece S.A.
Daikin AirconditioningCentral Europe Romania S.R.L.
Daikin Europe Brussels Office
Daikin Airconditioning Spain
Daikin Airconditioning Portugal
Daikin Europe N.V.Daikin Europe Coordination Center N.V.
Daikin Airconditioning Belgium N.V.Daikin Airconditioning France S.A.S.
Daikin Airconditioning Netherlands B.V.
Daikin Airconditioning UK Ltd.
Daikin Sweden A.B.
Daikin Klima Pazarlama Ltd. Sirketi
Daikin Industries Czech Republic s.ro.
Daikin Europe Moscow Office
Daikin Airconditioning South Africa (PTY) Ltd.
Daikin Europe Dublin Office
The Daikin Europe N.V. groupis a part of Daikin Industries Ltd
Umeda Center Bldg. 4-12, 2-chromeNakazaki-NishiKita-ku, Osaka 530-8323, Japan
Daikin Central Europe Slovakia Spol.s.ro
Daikin Airconditioning Central Europe Slovakia Spol.s.roDaikin Airconditioning Central Europe Predstavnistvo u Republici Hrvatskoj
1
F o r e w o r d
THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICESince our establishment in Ostend (Belgium) in 1972, we have updated and expanded our manufacturing facilities, including those opened more recently in Plzen and Brno (Czech Republic) and Cecchina (Italy) – through the acquisition of McQuay - to a point where they are now acknowledged as the most advanced in their fi eld in Europe. Furthermore, all our plants benefi t from our Japanese parent’s policy of zero defect production, super effi cient supply chain management and unrivalled research and development support.
These substantial production facilities are under pinned by a network of wholly owned affi liate companies in the UK, France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, Holland and Central Europe, as well as numerous independent distributors throughout Europe, Africa and the Middle East supported by several head offi ces in Ireland, Russia, Turkey, South Africa and the Middle East. Experienced and professional support of this order enables us to maintain an enviably close relationship with international markets, tailor our product programme to suit precise regional requirements and respond quickly and effi ciently to any area of potential market expansion.
THE LEADER IN PRODUCT QUALITYDaikin produces a highly energy effi cient and comprehensive range of quality indoor climate control products and systems for commercial, residential and industrial applications. Our product portfolio is based on four distinct core ‘pillars’:- state of the art direct expansion air conditioning - heat pump residential and light commercial heating, domestic hot water and cooling - applied central cooling and heating - medium to low temperature refrigeration Each pillar harnesses advanced technologies to deliver maximum energy effi ciency and minimum fuel consumption and running costs throughout the equipment life cycle. The width of our product range is also extensive and embracing in its coverage of these key indoor climate control disciplines to a point where we are confi dent of its ability to meet the requirements of our end user, specifi er, contractor and installer customer base at all times.
RESPECT FOR THE ENVIRONMENTDaikin has an enviable record in concern for environmental issues and applies it to all areas of the business, implementing and in many cases pre-empting, international and local environmental protective legislation. We seek to operate a zero waste and zero emissions policy in our manufacturing plants. Our products refl ect the concept of combining maximising energy effi ciency with maximum respect for the environment. Their utilisation of heat pump technology for example, results in far lower energy consumption and in the case of heating, drastically less CO2 emissions than are achievable with fossil fuel burning systems. Also their incorporation of numerous detailed features such as inverter control, heat recovery, economy and quiet operating modes, movement sensors among others, enhance user comfort without compromise to either effi ciency or the environment. Thus, the products contained in this catalogue are designed to represent the best possible answer to your air conditioning needs. Feel free to contact your local Daikin representative for further information and assistance. We are here to serve you!
THE FUTURE LEADERDaikin’s position at the forefront of air conditioning manufacturing and marketing is well established and widely acknowledged. Nevertheless, over the last few years we widened our product portfolio in order to offer customers a more comprehensive choice of indoor climate control solutions for the home, in business and at play. The successful moves into heat pump heating for residential and commercial applications and medium to low temperature refrigeration for retail and wholesale food outlets are testament to this policy. But our search for innovative solutions is ongoing and there will certainly be many more successes to come. The common denominators however, will remain, as they are today, the provision of individual comfort allied to innovation, quality, energy effi ciency and environmental acceptability.
2
3
A i r C o n d i t i o n i n g
Residential & Commercial 9Wall mounted units 10Flexi type units 14Floor standing units 164 -Way blow ceiling mounted cassette 18Ceiling suspended units 23Concealed ceiling units 27
Rooftops & Packaged Systems 39Concealed ceiling units 40Floor standing units 42Rooftops 47
T a b l e o f C o n t e n t s
Foreword 1Table of contents 3Environmental awareness 4Energy labeling 6
To consult the explanation of the pictogrammes,please refer to page 48 of this catalogue.
Intro_25-10-2006.indd 3Intro_25-10-2006.indd 3 8/09/2008 13:48:248/09/2008 13:48:24
4
Environmental Awareness
AIR CONDITIONING AND THE ENVIRONMENTAir conditioning systems provide a signifi cant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a signifi cant contribution to limiting the impact on the environment.A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product features that have an impact on reducing energy consumption: Fan only, Night set mode, Econo mode, Energy effi ciency, Movement sensor and Home leave operation
5
DAIKIN’S COMMITMENT TO THE ENVIRONMENTThe pioneering concern for the environment and natural resources is a part of the entire global Daikin operation at all levels: from product design, manufacturing processes, down to the responsibility each individual Daikin employee takes for the environment.
This commitment is refl ected in three areas: reducing waste in manufacturing and operations, recycling materials, and designing and producing energy-effi cient climate control equipment.
REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONSIn 1998, Daikin Europe N.V. became the fi rst air conditioning manufacturer in Europe to obtain ISO 14001 environmental certifi cation. In addition, since 2004, not only the manufacturing plants but Daikin sales companies as well have obtained ISO 14001 certifi cation, underlining Daikin’s commitment to the environment at all levels of our organisation.
These certifi ed environmental plans include the reduction of waste at all levels. Our environmental targets are high: Daikin Europe N.V. is committed to a zero waste policy whereby as much as possible of its by products can be reused, recycled or recovered as useful resources.
RECYCLING MATERIALSDaikin Europe N.V. is fi rmly committed to recycling materials in all areas of its operations. Wastewater is treated before being discharged into the city drainage system, with the recovered sludge being a useful ingredient in cement manufacturing. Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages the optimum use of resources. In addition to recycling, we invest signifi cantly in returnable packaging. The same high demands are also imposed on our suppliers.
Eliminating waste and optimum recycling reduce raw material consumption and contribute to effi cient manufacturing and operating processes, meaning fewer burdens on the environment.
ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENTDaikin’s commitment to being a leader in environmental developments has led to a string of innovations in climate control equipment:• Daikin’s use of inverter technology for example reduces start-up time by 33% and allows the compressor to consume
only the power it actually needs to meet the cooling/heating needs of the moment. • Linking the use of inverter technology to reluctance DC compressor motors has further improves effi ciency, allowing
Daikin units to obtain the highest effi ciency ratings in the market. • Daikin also produces computerised air conditioning monitoring and control systems designed to ensure maximum
energy effi ciency at all times, such as Daikin’s latest I-controller technology which offers customers refi ned and energy effi cient control of Daikin heat recovery air conditioning installations, including remote monitoring via the Internet.
This list of innovations could be expanded endlessly. More importantly, it clearly demonstrates that technological innovation and concern for the environment can go hand in hand. At Daikin, these environmental priorities form an integral part of our corporate culture and are refl ected in all of our products.
Choosing Daikin means you can be sure that the cooling systems you use are the safest possible for the environment.
6
AABB
CCDD
EEFF
GG
Energy Labeling
Energy labeling is part of a wider European Climate Change program that targets energy effi ciency as one method of reducing CO2 emissions in order to meet the targets of the Kyoto protocol. By this means the European Commission hopes that improved awareness will result in customers purchasing the most economical (ecological) answer to their needs.
WHAT?The energy label provides information on the energy consumption of the unit. Air conditioning units (with cooling capacity 12kW) are classifi ed in seven different categories (A to G), according to their energy consumption and color coded according to the category to which they belong. The most energy effi cient units will be included in the A category, indicated by a green arrow on the label – less effi cient units will belong in G class, indicated by a red arrow on the label. The end user can easily compare the effi ciency of equal types of units from different brands.
THE LABEL?WHAT IS MENTIONED ON THE LABEL?Logo and name of manufacturer; name of indoor and outdoor unit (*)
Energy effi ciency class of the unit in cooling mode:
A EER � 3.20
B 3.20 � EER � 3.00
C 3.00 � EER � 2.80
D 2.80 � EER � 2.60
E 2.60 � EER � 2.40
F 2.40 � EER � 2.20
G 2.20 � EER
EnergyManufacturerOutside unitInside unitMore efÞ cient
Less efÞ cientAnnual energy consumption,kWh in cooling mode(Actual consumption will depend on how the apliance is usedand climate)
Cooling output kWEnergy efÞ ciency ratioFull load (the higher the better)
Type Cooling only
Cooling + Heating Air cooled
Water cooledHeat output kW
Heating performanceA: higher G: lower
Noise(dB(A) re 1 pW)
Further information is containedin product brochures
Air-conditionerEnergy Label Directive 2002/31/EC
7
INDICATED ANNUAL ENERGY CONSUMPTIONThis fi gure indicates the approximate amount of energy consumed per year by the unit, based on a standard household model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN COOLING MODE AT FULL LOAD. In order to calculate the cost of annual energy consumption, you merely multiply this fi gure by your electricity tariff.
COOLING OUTPUTCooling output is defi ned as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is important to choose an air conditioning unit with a rated output suffi cient for your cooling/heating requirements. An oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.
ENERGY EFFICIENCY RATIO (EER)This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input). In other words, the higher the EER, the greater the energy effi ciency.
TYPETYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating systemCOOLING MODE: it indicates if the unit is air cooled or water cooled
HEATING OUTPUTHeating output is defi ned as the heating capacity in kW of the appliance, operating in heating mode at full load.
ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE:
A EER � 3.60
B 3.60 � EER � 3.40
C 3.40 � EER � 3.20
D 3.20 � EER � 2.80
E 2.80 � EER � 2.60
F 2.60 � EER � 2.40
G 2.40 � EER
Noise level: only for portable units.
(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted type) - for other units we refer to the multi brochure.
8
9
1. Wall mounted unit
FT-D / R-D 10FT-GA / R-G 11FA-F / R-FUV1 12FA-F / R-FUY1 13
2. Flexi type units
FL-HA / R-G 14FL-HA / R-G 15
3. Floor standing units
FV-L / R-FUV1 16FV-L / R-FUY1 17
4. 4-Way blow ceiling mounted cassettes
FHC-K / R-G 18FHC-K / R-G 19FHC-K / R-FUV1 20FHC-K / R-FUY1 21
5. Ceiling suspended units
FH-B / R-G 23FH-B / R-FUV1 24FH-B / R-FUY1 25
6. Concealed ceiling units
FDBG-A / R-G 27FDBG-A / R-FUV1 28FDBG-A / R-FUY1 29FDYB-C / RY-C 30FDYB-C / RY-CY 31FDMG-A / RG-AV 32FDMG-A / RG-AY 33FDMG-A / R-FUV1 34FDMG-A / R-FUY1 35FDYM-C / RY-C 36FDYM-C / RY-CY 37
Daikin residential air conditioning is the modern, economic and effi cient way to switch on to springtime - in the living room, dining room, kitchen or bedroom, night and day, throughout the year.Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and come in an elegant and up to date range of wall, fl oor and ceiling mounted indoor models. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and eliminates power surges and stop/start cycles.
Residential & Commercial
Wall Mounted Unit
! Air purifi cation fi lter with photocatalytic deodorising function
! Auto-restart after power failure! Filter cleaning indicator! Mould-proof air fi lter! Night set mode saves energy by preventing
overcooling or overheating during night time! Power-airfl ow dual fl aps! Self-diagnosis with digital display! Vertical auto-swing function moves the discharge
fl aps up and down for effi cient air distribution throughout the room
! Wide angle louvers provide a comfortable air fl ow throughout the entire room
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/minSound Pressure Heating High/Low dBARefrigerant TypePower Supply 1~/220-240V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower Supply 1~/220-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
FT25DVM FT35DVM2.62 (220V) 3.58 (220V)3.21 (220V) 3.20 (220V)
-A B
283x800x1959
8.8 / 7.4 / 5.9 9.9 / 8.3 / 6.836 / 28 39 / 31
R-22
R25DV1 R35DV1560x695x265
27 3319.4~46
46 (220V) 48 (220V)R-22
6.35 / 9.52 / 18 6.35 / 12.7 / 182515
FT-D / R-D
10
R25,35DV1FT25,35DVMARC433B55
Wall Mounted Unit
Auto-restart after power failure Dual air discharge fl ow for better air distribution Filter cleaning indicator Night set mode saves energy by preventing
overcooling or overheating during night time Vertical auto-swing function moves the discharge
fl aps up and down for effi cient air distribution throughout the room
Wide angle louvers provide a comfortable air fl ow throughout the entire room
Mould-proof air fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FT50GAVEA FT60GAVEACapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/minSound Pressure Cooling High/Medium/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R50GV1K9 R60GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
---
D
298x1,050x19012
14 / 12 / 10 14 / 12.4 / 10.843 / 39 / 35 46 / 42 / 38
R-221~/220-240V/50Hz
540x750x270 685x800x30042 61
19.4~5449 54
R-221~/220-240V/50Hz
6.35 / 15.9 / 1830
FT-GA / R-G
11
R60GV1k9FT50,60GAVEAARC423A18
FT-GAVEA en R-GV1K9.indd 11FT-GAVEA en R-GV1K9.indd 11 8/09/2008 13:51:438/09/2008 13:51:43
Wall Mounted Unit
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Fits neatly on a wall! Auto-swing function ensures effi cient air
distribution via louvers that close automatically when the unit is switched off
! High fan speed mode for further comfort.! All maintenance operations can be carried out
from the front of the unit! Daikin remote controls give you easy control at
your fi ngertips! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FA71FVEK9 FA100FVEK9Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R71FUV1 R100FUV1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional 2 steps optional
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
7.8(1)/7.7(2) 10.6(1)/10.5(2)
-
-
-360x1,570x200 360x1,690x200
26 2719 / 16 24 / 2041 / 37 45 / 41
R-221~/220-240V/50/60Hz
816x880x370 1,215x880x37087 117
21~5252 56
R-221~/220V-240V/50Hz
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FA-F / R-FUV1
12
R71FUV1FA71FVEK BRC1C61 BRC7C69W
Wall Mounted Unit
optional optional
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Fits neatly on a wall! Auto-swing function ensures effi cient air
distribution via louvers that close automatically when the unit is switched off
! High fan speed mode for further comfort.! All maintenance operations can be carried out
from the front of the unit! Daikin remote controls give you easy control at
your fi ngertips! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FA71FVEK9 FA100FVEK9Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R71FUY1 R100FUY1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
7.8(1)/7.7(2) 10.6(1)/10.5(2)
-
-
-360x1,570x200 360x1,690x200
26 2719 / 16 24 / 2041 / 37 45 / 41
R-221~/220-240V/50/60Hz
816x880x370 1,215x880x37084 109
21~5252 56
R-223~/380V-415V/50Hz
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FA-F / R-FUY1
13
R71FUY1FA71FVEK BRC1C61 BRC7C69W
Flexi Type Unit
! Attractive design suitable for most interiors with slim and rounded shapes.
! 24-Hour On/Off timer! Auto-restart after power failure! Filter cleaning indicator! Indoor unit On/Off switch! Air purifi cation fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FL35HAV1Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/minSound Pressure Cooling High/Medium/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R35GV1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
Note: Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
3.5
3.11 (220V) / 2.93 (240V)
-
B
490x1,050x20017
12.2 / 9.4 / 6.646 / 41 / 34
R-221~/220-240V/50Hz
540x750x27037
19.4~4648
R-221~/220-240V/50Hz
6.35 / 12.7 / 182515
FL-HA / R-G
14
R35GV1FL35HAV1ARC423A20
Flexi Type Unit
! Attractive design suitable for most interiors with slim and rounded shapes.
! 24-Hour On/Off timer! Auto-restart after power failure! Filter cleaning indicator! Indoor unit On/Off switch! Air purifi cation fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FL50HAV1Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/minSound Pressure Cooling High/Medium/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R50GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
Note: Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
5.0
2.58 (220V) / 2.35 (240V)
-
E
490x1,050x20017
11.4 / 9.9 / 8.547 (220V/240V) / 43 (220V/240V) / 39 (220V/240V)
R-221~/220-240V/50Hz
540x750x27042
19.4~5449
R-221~/220-240V/50Hz
6.35 / 15.9 / 1830
FL-HA / R-G
15
R50GV1K9FL50HAV1ARC423A20
Floor Standing Unit
! Ideal for installations where extra high ceilings could lead to ineffi cient heating from ceiling mounted units
! Horizontal auto swing louvres ensure comfortable airfl ow
! Manually adjustable vertical louvres! LCD displays text, numerals and graphics indicating
temperature setting, timer setting, auto-swing, fan speed etc.
! LCD panel can also be detached and used as a remote controller, enabling air conditioning to be controlled from another room or a cash register.
! Two selectable thermo-sensors! Easy installation and maintenance
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FV71LAVE3 FV100LAVE37.8(1)/7.7(2) 10.6(1)/10.5(2)
---
1,850x600x270 1,850x600x35039 46
18 / 14 28 / 2241 / 35 46 / 40
R-22
R71FUV1 R100FUV1816x880x370 1,215x880x370
87 11721~52
52 56R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FV-L / R-FUV1
16
R100FUV1FV100LAVE3
Floor Standing Unit
! Ideal for installations where extra high ceilings could lead to ineffi cient heating from ceiling mounted units
! Horizontal auto swing louvres ensure comfortable airfl ow
! Manually adjustable vertical louvres! LCD displays text, numerals and graphics indicating
temperature setting, timer setting, auto-swing, fan speed etc.
! LCD panel can also be detached and used as a remote controller, enabling air conditioning to be controlled from another room or a cash register.
! Two selectable thermo-sensors! Easy installation and maintenance
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FV71LAVE3 FV100LAVE3 FV125LAVE37.8(1)/7.7(2) 10.6(1)/10.5(2) 13.0(1)/12.8(2)
---
1,850x600x270 1,850x600x35039 46 47
18 / 14 28 / 22 32 / 2541 / 35 46 / 40 49 / 43
R-22
R71FUY1 R100FUY1 R125FUY1816x880x370 1,215x880x370
84 109 11021~52
52 56 57R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FV-L / R-FUY1
17
R100,125FUY1FV100,125LAVE3
4-Way Blow Ceiling Mounted Cassette
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Choice between 8 air fl ow distribution patterns! Possibility to shut 1 or 2 fl aps for easy installation
in corners! Air fl ow distribution for ceiling heights up to 4.2m
without loss of capacity.! Choice between 3 auto-swing positions for
maximum comfort: standard, draught prevention, ceiling soiling prevention
! Excellent low draught characteristics! Two selectable thermo-sensors! Drain-up pump with 750mm lift fi tted as standard! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FHC35KVE9Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60HzDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit R35GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower Supply 1~/220-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional standard 2 steps
optional
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
3.54(1)/3.5(2)
-
-
-230x840x840
2414 / 1033 / 29R-22
BYC125K-W1
40x950x9505
540x750x27037
19.4~4648
R-22
6.35 / 12.7 / 182515
FHC-K / R-G
18
R35GV1K9FHC35KVE9 BRC1C61 BRC7C613W
4-Way Blow Ceiling Mounted Cassette
Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
Choice between 8 air fl ow distribution patterns Possibility to shut 1 or 2 fl aps for easy installation
in corners Air fl ow distribution for ceiling heights up to 4.2m
without loss of capacity. Choice between 3 auto-swing positions for
maximum comfort: standard, draught prevention, ceiling soiling prevention
Excellent low draught characteristics Two selectable thermo-sensors Drain-up pump with 750mm lift fi tted as standard Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FHC50KVE9 FHC60KVE9Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60HzDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit R50GV1K9 R60GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower Supply 1~/220-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional standard 2 steps
optional
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
5.34(1)/5.30(2) 6.44(1)/6.4(2)
-
-
-230x840x840
2415 / 11 19 / 1433 / 29 35 / 30
R-22
BYC125K-W1
40x950x9505
540x750x270 685x800x30042 61
19.4~5449 54
R-22
6.35 / 15.9 / 1830
FHC-K / R-G
19
R60GV1K9FHC50,60KVE9 BRC1C61 BRC7C613W
FHC-KVE en R-GV1K9.indd 19FHC-KVE en R-GV1K9.indd 19 8/09/2008 13:53:308/09/2008 13:53:30
4-Way Blow Ceiling Mounted Cassette
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Choice between 8 air fl ow distribution patterns! Possibility to shut 1 or 2 fl aps for easy installation
in corners! Air fl ow distribution for ceiling heights up to 4.2m
without loss of capacity.! Choice between 3 auto-swing positions for
maximum comfort: standard, draught prevention, ceiling soiling prevention
! Excellent low draught characteristics! Two selectable thermo-sensors! Drain-up pump with 750mm lift fi tted as standard! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60HzDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
standard 2 steps
optional
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FHC71KVE9 FHC100KVE97.8(1)/7.7(2) 10.6(1)/10.5(2)
---
230x840x840 288x840x84024 28
19 / 14 28 / 2136 / 30 39 / 34
R-22
BYC125K-W1
40x950x9505
R71FUV1 R100FUV1816x880x370 1,215x880x370
87 11721~52
52 56R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FHC-K / R-FUV1
20
R100FUV1FHC71,100KVE9 BRC1C61 BRC7C613W
4-Way Blow Ceiling Mounted Cassette
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Choice between 8 air fl ow distribution patterns! Possibility to shut 1 or 2 fl aps for easy installation
in corners! Air fl ow distribution for ceiling heights up to 4.2m
without loss of capacity.! Choice between 3 auto-swing positions for
maximum comfort: standard, draught prevention, ceiling soiling prevention
! Excellent low draught characteristics! Two selectable thermo-sensors! Drain-up pump with 750mm lift fi tted as standard! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60HzDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
standard 2 steps
optional
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FHC71KVE9 FHC100KVE9 FHC125KVE97.8(1)/7.7(2) 10.6(1)/10.5(2) 13.0(1)/12.8(2)
---
230x840x840 288x840x84024 28
19 / 14 28 / 21 33 / 2435 / 30 39 / 34 42 / 36
R-22
BYC125K-W1
40x950x9505
R71FUY1 R100FUY1 R125FUY1816x880x370 1,215x880x370
84 109 11021~52
52 56 57R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FHC-K / R-FUY1
21
R100,125FUY1FHC71,100,125K BRC1C61 BRC7C613W
22
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity. Wider air discharge thanks to Coanda effect: up to
100 degrees Drain pump kit available as accessory Easy installation and maintenance Two selectable thermo-sensors
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FH50BVE FH60BVECapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R50GV1K9 R60GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
5.19(1)/5.1(2) 6.6(1)/6.5(2)
-
-
-195x960x680 195x1,160x680
24 2613 / 10 16 / 13
38 / 33R-22
1~/220-240V/50/60Hz
540x750x270 685x800x30042 61
19.4~5449 54
R-221~/220-240V/50Hz
6.35 / 15.9 / 1830
FH-B / R-G
23
R60GV1K9FH60BVE BRC1C61 BRC7E66
FH-BVE en R-GV1K9.indd 23FH-BVE en R-GV1K9.indd 23 8/09/2008 13:54:078/09/2008 13:54:07
Ceiling Suspended Unit
! Ideal solution for shops, restaurants or offi ces without false ceilings
! Compact design! Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings! Auto-swing function ensures effi cient air and
temperature distribution.! Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity.! Wider air discharge thanks to Coanda effect: up to
100 degrees! Drain pump kit available as accessory! Easy installation and maintenance! Two selectable thermo-sensors
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FH71BVE FH100BVE7.8(1)/7.7(2) 10.6(1)/10.5(2)
---
195x1,160x680 195x1,400x68027 32
17 / 14 24 / 2039 / 35 42 / 37
R-22
R71FUV1 R100FUV1816x880x370 1,215x880x370
87 11721~52
52 56R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FH-B / R-FUV1
24
R100FUV1FH100BVE BRC1C61 BRC7E66
Ceiling Suspended Unit
! Ideal solution for shops, restaurants or offi ces without false ceilings
! Compact design! Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings! Auto-swing function ensures effi cient air and
temperature distribution.! Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity.! Wider air discharge thanks to Coanda effect: up to
100 degrees! Drain pump kit available as accessory! Easy installation and maintenance! Two selectable thermo-sensors
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FH71BVE FH100BVE FH125BVE7.8(1)/7.7(2) 10.6(1)/10.5(2) 13.0(1)/12.8(2)
---
195x1,160x680 195x1,400x680 195x1,590x68027 32 35
17 / 14 24 / 20 30 / 2539 / 35 42 / 37 44 / 39
R-22
R71FUY1 R100FUY1 R125FUY1816x880x370 1,215x880x370
84 109 11021~52
52 56 57R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FH-B / R-FUY1
25
R100,125FUY1 BRC1C61 BRC7E66 FH100BVE
26
Concealed Ceiling Unit
! Leaves maximum fl oor and wall space for furniture, decorations and fi ttings
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Compact dimensions, can easily be mounted in a ceiling void of only 270mm
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FDBG50AVE FDBG60AVECapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit R50GV1K9 R60GV1K9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
5.34(1)/5.30(2) 7.03(1)/6.97(2)
-
-
-260x900x580 260x1,300x580
23 3113 / 11 18 / 1541 / 38 42 / 39
R-221~/220-240V/50/60Hz
540x750x270 685x800x30042 61
19.4~5449 54
R-221~/220-240V/50Hz
6.35 / 15.9 / 1830
FDBG-A / R-G
27
R60GV1K9FDBG60AVEKRC47-1A
Concealed Ceiling Unit
! Leaves maximum fl oor and wall space for furniture, decorations and fi ttings
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Compact dimensions, can easily be mounted in a ceiling void of only 270mm
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FDBG71AVE7.8(1)/7.7(2)
---
260x1,300x58031
18 / 1542 / 39R-22
R71FUV1816x880x370
8721~52
52R-22
9.52 / 15.9 / 2650
FDBG-A / R-FUV1
28
R71FUV1FDBG71AVEKRC47-1A
Concealed Ceiling Unit
Leaves maximum fl oor and wall space for furniture, decorations and fi ttings
Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
Compact dimensions, can easily be mounted in a ceiling void of only 270mm
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50/60Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FDBG71AVE7.8(1)/7.7(2)
---
260x1,300x58031
18 / 1542 / 39R-22
R71FUY1816x880x370
8421~52
52R-22
9.52 / 15.9 / 2650
FDBG-A / R-FUY1
29
R71FUY1FDBG71AVEKRC47-1A
FDBG-AVE en R-FUY1.indd 29FDBG-AVE en R-FUY1.indd 29 8/09/2008 13:55:348/09/2008 13:55:34
Concealed Ceiling Unit
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure
save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYB30CV1M FDYB40CV1M FDYB60CV1M FDYB71CV1M FDYB90CV1M FDYB125CV1MCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min
SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA
SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA
SH/H/M/L dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RY30CV1M RY40CV1M RY60CV1M RY71CV1M RY80CV1M RY90CV1M RY100CV1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
standard heat pump
4 steps
2.782 3.605 5.570 6.740 8.602 8.792 9.818
2.782 3.515 5.800 7.330 8.499 8.792 10.257
3.18 / 3.31 2.95 / 3.31 3.03 / 3.32 2.95 / 3.24 2.75 / 3.15 2.82 / 2.85 3.06 / 3.20
438 611 919 1,143 1,562 1,558 1,605
B / C C / C B / C C / C D/D C/D B/D
261x765x411 261x1,065x411 261x1,200x411 378x929x541 378x1,045x54117 21 22 25 39 42
7.62 / 7.08 / 5.94 15.3 / 13.32 / 9.9 18.42 / 18.18 / 16.14 21.78 / 20.4 / 16.44 - -- 20.64 / 24.9 / 22.38 / 20.94 33.72 / 30.00 / 28.32 / 27.48
57 / 54 / 51 61 / 58 / 52 65 / 64 / 60 66 / 64 / 61 - -- 76 / 73 / 69 / 64 78 / 76 / 72 / 68
33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 - -- 49 / 46 / 42 / 38 51 / 49 / 45 / 41
R-221~/220-240V/50Hz
540x700x250 648x855x328 750x855x328 850x1,030x40032 59 62 68 95
19.0~46.0-9.0~18.0
46 49 51 52 54 58R-22
1~/220-240V/50Hz6.35 / 9.52 6.35 / 12.7 6.35 / 15.9 9.52 / 15.9 9.52 / 19.1
12 15 45
FDYB-C / RY-C
30
FDYB-CSLM3 RY-CV1M
Concealed Ceiling Unit
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure
save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYB90CV1M FDYB125CV1M FDYB140CV1M FDYB160CV1MCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling SH/H/M/L m³/minSound Power Cooling SH/H/M/L dBASound Pressure Cooling SH/H/M/L dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RY90CY1M RY125CY1M RY140CY1M RY160CY1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
standard heat pump
4 steps
8.792 11.723 14.654 16.410
8.792 11.723 15.533 16.410
2.84 / 2.87 3.22 / 3.50 2.89 / 3.47 2.79 / 3.38
1,548 1,822 2,535 2,942
C / D A / B C / B D / C
378x929x541 378x1,045x541 378x1,299x541 378x1,499x54139 42 54 62
26.64 / 24.9 / 22.38 / 20.94 33.72 / 30.00 / 28.32 / 27.48 42.78 / 37.68 / 37.08 / 35.94 48.12 / 45.90 / 43.02 / 41.5876 / 73 / 69 / 64 78 / 76 / 72 / 68 78 / 76 / 73 / 70 79 / 78 / 75 / 7149 / 46 / 42 / 38 51 / 49 / 45 / 41 53 / 52 / 50 / 47 55 / 53 / 50 / 47
R-221~/220-240V/50Hz
850x1,030x40095 100 105 108
19.0~46.0-9.0~18.0
58 61R-22
3~/380-415V/50Hz9.52 / 15.9 9.52 / 19.1 12.7 / 19.1
45 35
FDYB-C / RY-CY
31
FDYB-CSLM3 RY-CY1M
Concealed Ceiling Unit
! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible! Medium external static pressure facilitates unit use
with fl exible ducts of varying lengths
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
Note (1) Cooling capacities are based on: indoor temp. 27°CDB/81°FDB, 19.5°CWB/67°FWB; outdoor temp. 35°CDB/95°FDB, 24°CWB/75°FWB; piping length: 5m (horizontal)Note (2) Cooling capacities are based on: indoor temp. 27°CDB/81°FDB, 19.0°CWB/66°FWB; outdoor temp. 35°CDB/95°FDB, 24°CWB/75°FWB; piping length: 5m (horizontal) Note (3) Cooling capacities are based on: indoor temp. 29°CDB/84°FDB, 19.0°CWB/66°FWB; outdoor temp. 46°CDB/115°FDB, 24°CWB/75°FWB; piping length: 7.5m (horizontal); Standard: SSA 385/386
FDMG71AV18.8(1)/8.7(2)/7.1(3)
---
305x1,350x6804323
42 / 38R-22
RG71AV1816x880x370
8721~52
52R-22
9.52 / 15.9 / 2650
FDMG-A / RG-AV
32
RG71AV1FDMG71AV1KRC47-1A
Concealed Ceiling Unit
! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible! Medium external static pressure facilitates unit use
with fl exible ducts of varying lengths
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kWEER NominalAnnual energy consumption kWhEnergy Labeling CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
Note (1) Cooling capacities are based on: indoor temp. 27°CDB/81°FDB, 19.5°CWB/67°FWB; outdoor temp. 35°CDB/95°FDB, 24°CWB/75°FWB; piping length: 5m (horizontal)Note (2) Cooling capacities are based on: indoor temp. 27°CDB/81°FDB, 19.0°CWB/66°FWB; outdoor temp. 35°CDB/95°FDB, 24°CWB/75°FWB; piping length: 5m (horizontal) Note (3) Cooling capacities are based on: indoor temp. 29°CDB/84°FDB, 19.0°CWB/66°FWB; outdoor temp. 46°CDB/115°FDB, 24°CWB/75°FWB; piping length: 7.5m (horizontal); Standard: SSA 385/386
FDMG71AV1 FDMG140AV1 FDMG180AV18.8(1)/8.7(2)/7.1(3) 14.5(1)/14.2(2)/12.3(3) 17.2(1)/16.8(2)/15.1(3)
---
305x1,350x680 305x1,550x680 305x1,900x68043 52 5823 42
42 / 38 46 / 37 47 / 37R-22
RG71AY1 RG140AY1 RG180AY1816x880x370 1,345x880x370
84 113 11421~52 21~50
52 55 56R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 26 9.52 / 19.1 / 2650
FDMG-A / RG-AY
33
RG71AY1FDMG71AV1KRC47-1A
Concealed Ceiling Unit
! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible! Medium external static pressure facilitates unit use
with fl exible ducts of varying lengths
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Gross kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 1~/220V-240V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (3) Cooling capacities are based on: indoor temp. 29°CDB/84°FDB, 19.0°CWB/66°FWB; outdoor temp. 46°CDB/115°FDB, 24°CWB/75°FWB; piping length: 7.5m (horizontal); Standard: SSA 385/386
FDMG100AV110.6(1)/10.5(2)/8.0(3)
---
305x1,550x6805134
44 / 36R-22
R100FUV11,215x880x370
11721~52
56R-22
9.52 / 19.1 / 2650
FDMG-A / R-FUV1
34
R100FUV1FDMG100AV1KRC47-1A
Concealed Ceiling Unit
! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible! Medium external static pressure facilitates unit use
with fl exible ducts of varying lengths
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Gross kWEER NominalAnnual energy consumption kWhEnergy Labeling CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/minSound Pressure Cooling High/Low dBARefrigerant TypePower Supply 1~/220-240V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (2) Nominal cooling capacities are based on: return air temperature 27°CDB,19.0°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)Note (3) Cooling capacities are based on: indoor temp. 29°CDB/84°FDB, 19.0°CWB/66°FWB; outdoor temp. 46°CDB/115°FDB, 24°CWB/75°FWB; piping length: 7.5m (horizontal); Standard: SSA 385/386
FDMG100AV1 FDMG125AV110.6(1)/10.5(2)/8.0(3) 13.1(1)/12.9(2)/11.2(3)
---
305x1,550x68051 5234 37
44 / 36 45 / 37R-22
R100FUY1 R125FUY11,215x880x370
109 11021~52
56 57R-22
9.52 / 19.1 / 2650
FDMG-A / R-FUY1
35
R100,125FUY1FDMG100,125AV1KRC47-1A
Concealed Ceiling Unit
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure
save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYM30CV1M FDYM40CV1M FDYM60CV1M FDYM71CV1M FDYM80CV1M FDYM90CV1M FDYM100CV1M FDYM125CV1MCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min
SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA
SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA
SH/H/M/L dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RY30CV1M RY40CV1M RY60CV1M RY71CV1M RY80CV1M RY90CV1M RY100CV1M RY125CV1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
standard heat pump
4 steps
2.780 3.600 5.570 6.890 7.913 8.792 8.602 8.792 10.257 9.818 9.818 11.723
2.780 3.600 5.800 7.030 8.206 8.792 8.499 8.792 10.550 10.257 10.257 11.723
3.09 / 3.52 2.84 / 3.39 2.94 / 3.14 2.63 / 2.77 2.56 / 3.11 2.85 / 2.87 2.73 / 3.11 2.80 / 2.82 3.11 / 3.19 30.1 / 3.14 30.1 / 3.14 3.14 / 3.62
450 634 948 1,308 1,546 1,545 1,577 1,573 1,652 1,633 1,633 1,864
B / B C / C C / D D / E E / D C / D D / D D / D B / D B / D B / D B / A
261x765x411 261x905x411 261x1,065x411 261x1,200x411 285x1,007x600 378x929x541 305x1,302x638 378x1,045x54117 21 22 25 38 39 41 42
8.52 / 7.38 / 6.24 14.46 / 12.48 / 10.20 18.96 / 18.12 / 16.68 18.96 / 21.54 / 16.68 -- 24.06 / 22.92 / 21.78 / 20.10 25.50 / 23.52 / 21.54 / 20.10 43.62 / 41.64 / 40.20 / 38.22 31.14 / 30.00 / 28.02 / 25.50
57 / 54 / 51 61 / 58 / 52 65 / 64 / 60 66 / 64 / 61 -- 67 / 64 / 61 / 57 76 / 73 / 69 / 64 80 / 76 / 73 / 70 78 / 76 / 72 / 68
33 / 20 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 -- 44 / 41 / 38 / 34 49 / 46 / 42 / 38 55 / 51 / 48 / 45 51 / 49 / 45 / 41
R-221~/220-240V/50Hz
540x700x250 648x855x328 750x855x328 850x1,030x40032 59 62 68 95 100
19.0~46.0-9.0~18.0
46 49 51 52 54 58R-22
1~/220-240V/50Hz6.35 / 9.52 6.35 / 12.7 6.35 / 15.9 9.52 / 15.9 9.52 / 19.1
12 15 45
FDYM-C / RY-C
36
FDYM-CSLM3 RY-CV1M
Concealed Ceiling Unit
! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure
save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYM80CV1M FDYM90CV1M FDYM100CV1M FDYM125CV1M FDYM140CV1M FDYM160CV1MCapacity Cooling capacity Standard kW
Heating capacity Standard kWEER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min
SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA
SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA
SH/H/M/L dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RY90CY1M RY125CY1M RY140CY1M RY160CY1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
standard heat pump
4 steps
8.792 8.792 11.137 11.723 14.654 16.410
8.792 8.792 11.280 11.723 15.533 16.410
2.86 / 2.89 2.81 / 2.84 2.98 / 3.28 3.17 / 3.65 2.90 / 3.49 2.73 / 3.30
1,535 1,563 1,868 1,849 2,524 3,005
C / D C / D C / C B / A C / B D / C
285x1,007x600 378x929x541 305x1,302x638 378x1,045x541 378x1,299x541 378x1,499x54138 39 41 42 54 62
-24.06 / 22.92 / 21.78 / 20.10 25.50 / 23.52 / 21.54 / 20.10 43.62 / 41.64 / 40.20 / 38.22 31.14 / 30.00 / 28.02 / 25.50 45.00 / 39.06 / 36.24 / 34.26 46.74 / 43.32 / 40.50 / 36.54
-67 / 64 / 61 / 57 76 / 73 / 69 / 64 80 / 76 / 73 / 70 78 / 76 / 72 / 68 78 / 76 / 73 / 70 79 / 78 / 75 / 71
-44 / 41 / 38 / 34 49 / 46 / 42 / 38 55 / 51 / 48 / 45 51 / 49 / 45 / 41 53 / 52 / 50 / 47 55 / 53 / 50 / 47
R-221~/220-240V/50Hz
850x1,030x40095 100 105 108
19.0~46.0-9.0~18.0
58 61R-22
3~/380-415V/50Hz9.52 / 15.9 9.52 / 19.1 12.7 / 19.1
45 35
FDYM-C / RY-CY
37
FDYM-CSLM3 RY-CY1M
38
39
PACKAGED SYSTEMSFD-K / R-FUY1 40FD-K / RU-K 41FRPJ-P / CRJ-PAYE 42FRPJ-P / CRJ-PAYE 43FRJ-P / CRJ-PYE 44
ROOF TOP UNITSUAT-AMY1 47
A range of high performance, low energy consumption air
cooled packaged roof top units is produced by Daikin for
supermarket, warehouse, factory, hotel, hospital, cinema and
large store applications.
Heat pump ‘plug and play’ versions are easy to install and
available as fully integrated systems comprising compressor,
evaporator and condensing units for air transmission through
ductwork to the conditioned space.
Roof Top & Packaged Systems
Concealed Ceiling Unit
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Blends unobtrusively with any interior décor! High external static pressure facilitates unit use
with fl exible ducts of varying lengths! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Gross kWEER NominalAnnual energy consumption kWhEnergy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50Hz
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure Cooling dBARefrigerant TypePower Supply 3~/380-415V/50HzPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional optional
Note (1) Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
FD03KY1 FD04KY1 FD05KY18.1(1) 11.0(1) 14.0(1)
---
450x650x850 450x900x85051 59 7226 30 4646 49
R-22
R71FUY1 R100FUY1 R125FUY1816x880x370 1,215x880x370
84 109 11021~52
52 56 57R-22
9.52 / 15.9 / 26 9.52 / 19.1 / 2650
FD-K / R-FUY1
40
R100,125FUY1FD05KY1KRC47-3A
Concealed Ceiling Unit
! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
! Blends unobtrusively with any interior décor! High external static pressure facilitates unit use
with fl exible ducts of varying lengths! Centralised control of several units can be
achieved via 3 wired controls: centralised remote control, unifi ed on/off control, schedule timer
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FD06KY1 FD08KY1 FD10KY1 FD15KY1 FD20KY1Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound pressure Cooling dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RU06KY1 RU08KY1 RU10KY1 RU08KY1+RU08KY1 RU10KY1+RU10KY1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
optional optional
Note: Nominal cooling capacities are based on: return air temperature 27°CDB,19.5°CWB; outdoor: 35°CDB; equivalent refrigerant piping length 5m (horizontal)
17.4 24.3 29.7 48.6 59.3
-
-
-450x1,130x850 500x1,130x850 500x1,330x850 625x1,620x850 625x1,980x850
79 93 104 161 18752 68 83 136 16651 51 53 58 60
R-223~/380-415V/50Hz
1,345x880x320 1,220x1,280x690 1,440x1,280x690 1,220x1,280x690 1,440x1,280x690112 177 190 177 190
21~5259 60 61 60 61
R-223~/380-415V/50Hz
9.52 / 19.1 12.7 / 25.4 15.9 / 31.8 12.7 / 25.4 15.9 / 31.850
FD-K / RU-K
41
RU08KY1FD08KY1KRC47-3A
Floor Standing Unit
! Ideal for use in larger areas! Easy to install! Easy operation and maintenance! Electronic room thermostat! Washable air fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FRPJ140PYE FRPJ200PYE FRPJ280PYECapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Pressure Cooling Medium dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit CRJ140PAYE CRJ200PAYE CRJ280PAYEDimensions (Height x Width x Depth) mmWeight kgSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mm
Note (1) Cooling capacities are based on: indoor air temp. 27°CDB,19.5°CWB; outdoor temp. 35°CDB Note (2) Cooling capacities are based on: indoor air temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
13.0/14.6(1) 12.8/14.3(2) 18.9/21.0(1) 18.6/20.6(2) 26.4/29.4(1) 25.9/28.9(2)
-
-
-1,640x950x510 1,640x1,170x510 1,640x1,470x510
170 230 27042 63 8353 55 57
R-223~/380-415/400-440V/50/60Hz
1,425x820x295 1,220x1,280x690 1,440x1,280x69052 94 104
55/56 56/57R-22
3~/380-415/400-440V/50/60Hz9.52 / 15.9 12.7 / 19.1 15.9 / 22,2
FRPJ-P / CRJ-PAYE
42
CRJ140,200,280PAYEFRPJ140,200,280P
Floor Standing Unit
! Ideal for use in larger areas! Easy to install! Easy operation and maintenance! Electronic room thermostat! Washable air fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FRJ400PYE FRJ560PYECapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Pressure Cooling Medium dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit CRJ200PAYE+CRJ200PAYE CRJ280PAYE+CRJ280PAYEDimensions (Height x Width x Depth) mmWeight kgSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mm
Note (1) Cooling capacities are based on: indoor air temp. 27°CDB,19.5°CWB; outdoor temp. 35°CDB Note (2) Cooling capacities are based on: indoor air temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
37.6/42.2(1) 36.9/41.4(2) 53.3/59.4(1) 52.3/58.3(2)
-
-
-1,870x1,470x720 1,870x1,810x720
420 460120 16560 63
R-223~/380-415/400-440V/50/60Hz
1,220x1,280x690 1,440x1,280x69094 104
55/56 56/57R-22
3~/380-415/400-440V/50/60Hz12.7 / 19.1 15.9 / 22,2
FRJ-P / CRJ-PAYE
43
CRJ200,280PAYEFRJ400,560P
Floor Standing Unit
! Ideal for use in larger areas! Easy to install! Easy operation and maintenance! Electronic room thermostat! Washable air fi lter
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FRJ630PYE FRJ800PYE FRJ1120PYECapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label CoolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Pressure Cooling Medium dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit CRJ315PYE+CRJ315PYE CRJ400PYE+CRJ400PYE CRJ560PYE+CRJ560PYEDimensions (Height x Width x Depth) mmWeight kgSound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mm
Note (1) Cooling capacities are based on: indoor air temp. 27°CDB,19.5°CWB; outdoor temp. 35°CDB Note (2) Cooling capacities are based on: indoor air temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
59.4/66.5(1) 58.3/65.3(2) 75.9/85.0(1) 74.5/83.5(2) 107.6/119.8(1) 105.7/117.7(2)
-
-
1,870x1,810x720 1,850x1,760x1,050 1,850x1,960x1,200490 780 1,000180 240 33063 65 67.5
R-223~/380-415/400-440V/50/60Hz
1,275x980x980 1,115x1,700x980 1,275x1,960x980105 145 205
55/58 58/60 60/62R-22
3~/380-415/400-440V/50/60Hz15.9 / 22,2 19.1 / 25.4 22,2 / 31.8
FRJ-P / CRJ-PYE
-
44
CRJ315,400,560PYEFRJ630,800,1120P
45
UAT-AMY1
UAT-AMY1
COOLING ONLY NON-INVERTEROutdoor units UAT180AMY1 UAT240AMY1 UAT280AMY1 UAT320AMY1 UAT450AMY1 UAT560AMY1 UAT700AMY1 UAT850AMY1 UATC10AMY1 UATC12AMY1Capacity Cooling Minimum kW 17.291 23.446 29.307 33.996 43.961 58.614 73.268 87.921 96.420 118.401Power Input Cooling Nominal kW 5.61 8.10 10.50 11.56 15.60 20.70 27.56 35.96 39.87 46.80EER Nominal 3.08 2.89 2.79 2.94 2.82 2.83 2.66 2.44 2.42 2.53Air Flow Rate Evaporator Cooling m³/min 51 80 100 102 160 190 227 272 312 354External Static Pressure Pa 98 98 98 98 196 196 294 294 294 294Condensation Drain Size Diameter (OD) mm 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4Casing Colour Light Grey
Material Electro galvanised mild steelDimensions Unit HxWxD mm 1000x1100x1530 1000x1300x1530 1000x1300x1530 1000x1300x1530 1200x1990x1670 1200x1990x1670 1735x2250x2800 1735x2250x2800 1974x2252x3180 1974x2252x3180Weight Unit kg 295 370 400 425 665 765 1200 1350 1510 1600Air Flow Rate Condensor Cooling m³/min 127 160 160 227 320 320 566 566 566 566Operation Range Cooling Min °CDB 20°C~54°CSound Level Sound power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R22Power Supply 3~/50Hz/380-415V
47
COOLING ONLY NON-INVERTEROutdoor units UAT180AMY1 UAT240AMY1 UAT280AMY1 UAT320AMY1 UAT450AMY1 UAT560AMY1 UAT700AMY1 UAT850AMY1 UATC10AMY1 UATC12AMY1Capacity Cooling Minimum kW 17.291 23.446 29.307 33.996 43.961 58.614 73.268 87.921 96.420 118.401Power Input Cooling Nominal kW 5.61 8.10 10.50 11.56 15.60 20.70 27.56 35.96 39.87 46.80EER Nominal 3.08 2.89 2.79 2.94 2.82 2.83 2.66 2.44 2.42 2.53Air Flow Rate Evaporator Cooling m³/min 51 80 100 102 160 190 227 272 312 354External Static Pressure Pa 98 98 98 98 196 196 294 294 294 294Condensation Drain Size Diameter (OD) mm 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4Casing Colour Light Grey
Material Electro galvanised mild steelDimensions Unit HxWxD mm 1000x1100x1530 1000x1300x1530 1000x1300x1530 1000x1300x1530 1200x1990x1670 1200x1990x1670 1735x2250x2800 1735x2250x2800 1974x2252x3180 1974x2252x3180Weight Unit kg 295 370 400 425 665 765 1200 1350 1510 1600Air Flow Rate Condensor Cooling m³/min 127 160 160 227 320 320 566 566 566 566Operation Range Cooling Min °CDB 20°C~54°CSound Level Sound power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R22Power Supply 3~/50Hz/380-415V
Rooftop
! Easy to install ‘plug and play’ concept plus single installation confi guration.
! No additional piping is required since indoor and outdoor sides are pre-connected.
! Factory pre-charged refrigerant ensures clean and effi cient operation.
! Belt driven fan enables air volume and static pressure to be adjusted as required.
! Flat top unit design allows maximum utilization of warehouse and container space.
! High effi ciency and reliable scroll compressor. ! Fan can be mounted for horizontal or vertical
airfl ow inlet and discharge (UAT320AMY1 only).
COOLING ONLY NON-INVERTEROutdoor units UAT180AMY1 UAT240AMY1 UAT280AMY1 UAT320AMY1 UAT450AMY1 UAT560AMY1 UAT700AMY1 UAT850AMY1 UATC10AMY1 UATC12AMY1Capacity Cooling Minimum kWPower Input Cooling Nominal kWEER NominalAir Flow Rate Evaporator Cooling m³/minExternal Static Pressure PaCondensation Drain Size Diameter (OD) mmCasing Colour Light Grey
Material Electro galvanised mild steelDimensions Unit HxWxD mmWeight Unit kgAir Flow Rate Condensor Cooling m³/minOperation Range Cooling Min °CDBSound Level Sound power dBARefrigerant TypePower Supply 3~/50Hz/380-415V
POWER Supply
T1 = 3~, 220V, 50HZV1 = 1~, 220-240V, 50HZVE = 1~, 220-240V, 50HZ/60HZV3 = 1~, 230V, 50HZVM = 1~, 220~240V/220~230V, 50HZ/60HZW1 = 3N~, 400V, 50HZY1 = 3~, 400V, 50HZ
MEASURING Conditions
COOLING ONLY
1) nominal cooling capacities are based on:indoor temperature 27°CDB/19°CWBoutdoor temperature 35°CDBrefrigerant piping length 7.5mlevel difference 0m
HEAT PUMP
1) nominal cooling capacities are based on:indoor temperature 27°CDB/19°CWBoutdoor temperature 35°CDBrefrigerant piping length 7.5mlevel difference 0m2) nominal heating capacities are based on:indoor temperature 20°CDBoutdoor temperature 7°CDB/6°CWBrefrigerant piping length 7.5mlevel difference 0m
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates.For more detailed information please consult our technical databooks.
48
Fan onlyThe air conditioner can be used as fan, blowing air without cooling or heating.
Dry programmeAllows humidity levels to be reduced without variations in room temperature.
Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature(heat pump types only).
Auto-restartThe unit restarts automatically at the original settings after power failure.
Draught preventionWhen starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Horizontal auto swingPossibility to select automatic horizontal moving of the air discharge louvre, for uniform air fl ow and temperature distribution.
Vertical auto swingPossibility to select automatic vertical moving of the air discharge louvre, for uniform air fl ow and temperature distribution.
Wired remote controlWired remote control to start, stop and regulate the air conditioner from a distance.
Infrared remote controlInfrared remote control with LCD to start, stop and regulate the air conditioner from a distance.
Econo modeThis function decreases the power consumption so that other applicances that need large power consumption can be used. This function is also energy saving.
Single screw compressorCompact, high effi cient, silent reliable Daikin compressor.Maintenance free (inspection only after 40,000 hours of operation)
Scroll compressorSilent, reliable Daikin compressor used in medium sized outdoor units.
Self-diagnosisSimplifi es maintenance by indicating system faults or operating anomalies.
Ceiling soiling preventionA special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.
Night set modeSaves energy, by preventing overcooling or overheating during night time.
24 Hour timerTimer can be set to start cooling/heating anytime during a 24-hour period.
Auto fan speedAutomatically selects the necessary fan speed to reach or maintain the set temperature.
Energy effi ciencyDaikin air conditioners are energy effi cient and economical.
Movement sensorThe sensor detects whether someone is in the room. When the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.
Home leave operationDuring absence, the indoor temperature can be maintained at a certain level.
‘We Care’ Icons
A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product features that have an impact on reducing energy consumption:
49
3-D Air fl owThis function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right to the corners of even large spaces.
Comfort modeThe new fl ap changes the discharge angle horizontally for cooling operation and downward vertically for heating operation. This in order to prevent cold or warm air from blowing directly on the body.
Night quiet mode (cooling only)Lowers the operation sound of the outdoor unit automatically by 3dB(A) by removing a jumper wire on the outdoor unit. This function can be deactivated if the jumper wire is reinstalled on the outdoor unit.
Indoor unit silent operationLowers the operation sound of the indoor unit by 3dB(A). This function is useful when studying or sleeping.
Outdoor unit silent operationLowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet environment for the neighbourhood.
Comfortable sleeping modeIncreased comfort function that follows a specifi c temperature fl uctuation rhythm.
Powerful modeIf the temperature in the room is too high/low, it can be cooled down/heated quickly by selecting the ‘powerful mode’. After the powerful mode is turned off, the unit returns to the preset mode.
Super multi plusUp to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode.
Multi model applicationUp to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode.
Twin/triple/double twin application2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All indoor units operate within the same mode (cooling or heating) from one remote control.
Drain pump kitFacilitates condensation draining from the indoor unit.
Photocatalytic deodorising fi lterRemoves airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses, microbes, this to ensure a steady supply of clean air.
Air purifi cation fi lterRemoves airborne dust particles and prevents the propagation of bacteria and viruses to ensure a steady supply of clean air.
Air fi lterRemoves airborne dust particles to ensure a steady supply of clean air.
Double thermostat functionControls the temperature via a sensor on the air conditioner or via a sensor on the remote control.
Whisper quietDaikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neighbourhood.
Fan speed steps Allows to select up to the given number of fan speed.
Centralised controlCentralised control to start, stop and regulate several air conditioners from one central point.
TimerAllows to preset the air conditioner to start/stop at a specifi ed time.
50