resource reports appendix maps figures

49
January 2012 Corpus Christi Liquefaction, LLC Corpus Christi Liquefaction Project APPENDIX 1A MAPS and FIGURES

Upload: allyson-johnson

Post on 04-Dec-2015

218 views

Category:

Documents


0 download

DESCRIPTION

12312312334fswdf

TRANSCRIPT

Page 1: Resource Reports Appendix Maps Figures

January 2012

Corpus Christi Liquefaction, LLC Corpus Christi Liquefaction Project

APPENDIX 1A

MAPS and FIGURES

Page 2: Resource Reports Appendix Maps Figures

January 2012

Figures Included in Appendix 1A

Figure No. Subject 1A-1 Site Boundary on Aerial Image 1A-2 Dredge Area Detail 1A-3 Dredged Material Placement Areas 1A-4 Site Plan, Including Location Relative to La Quinta Extension 1A-5 Typical Full Containment LNG Storage Tank with Integrated

Concrete Secondary Containment 1A-6 Typical Full Containment LNG Storage Tank Construction

Sequence

Page 3: Resource Reports Appendix Maps Figures
john.scott
Text Box
Figure 1A-1
Page 4: Resource Reports Appendix Maps Figures
john.scott
Text Box
Figure 1A-2
Page 5: Resource Reports Appendix Maps Figures
john.scott
Text Box
Figure 1A-3
Page 6: Resource Reports Appendix Maps Figures
john.scott
Text Box
CORPUS CHRISTI LIQUEFACTION PROJECT Figure 1A-4 Site Plan and Location Relative to La Quinta Channel Extension
Page 7: Resource Reports Appendix Maps Figures

 

 

Figure 1A-5. Typical Full Containment LNG Storage Tank with Integrated Concrete Secondary Containment

Page 8: Resource Reports Appendix Maps Figures

Figure 1A-6. Typical full containment LNG storage tank construction sequence

Page 9: Resource Reports Appendix Maps Figures

January 2012

Corpus Christi Liquefaction, LLC Corpus Christi Liquefaction Project

APPENDIX 1B

AGENCY CORRESPONDENCE

Page 10: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Mr. Jeff Robinson U.S. Environmental Protection Agency Region 6 1445 Ross Avenue, Suite 1200 Dallas, TX 75202 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Mr. Robinson, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. Corpus Christi Liquefaction will be consulting with USEPA as necessary during the preparation of required permit applications. However, to assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000, and TCEQ Air Permit Nos. 70741 and PSD-TX-1038.

Page 11: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 12: Resource Reports Appendix Maps Figures
Page 13: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Mr. Lloyd Mullins U.S. Army Corps of Engineers Corpus Christi Field Office 5151 Flynn Parkway, Suite 306 Corpus Christi, TX 78411 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Mr. Mullins, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. met with you and your staff about in November 2011. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. Cheniere Energy has been actively working with the USACE to finalize compensatory mitigation plans under its existing Section 404/10 Permit for the LNG import terminal proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from FERC under FERC Docket No. CP04-37-000. However, to assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process for the Liquefaction Project, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project and that are not addressed under the existing permit.

Page 14: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 15: Resource Reports Appendix Maps Figures
Page 16: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Ms. Dawn Whitehead Deputy Field Office Supervisor U.S. Fish & Wildlife Service Corpus Christi Ecological Services Field Office c/o TAMU-CC 6300 Ocean Drive, #5837 Corpus Christi, TX 78412 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Ms. Whitehead, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. To assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000. On May 13, 2004 the U.S. Fish and Wildlife Service concurred with a determination that the LNG terminal project would have no effect on federally listed species (Consultation #: 2-11-03-I-0329).

Page 17: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 18: Resource Reports Appendix Maps Figures
Page 19: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Dr. Roy Crabtree Regional Administrator NOAA Fisheries, Southeast Region 263 13th Avenue South St. Petersburg, FL 33701 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Dr. Crabtree, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. met with your agency’s staff about in November 2011. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. To assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000. During that time frame NOAA Fisheries, Habitat Conservation Division, and Protected Resources Division, provided comments to Cheniere and the FERC.

Page 20: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 21: Resource Reports Appendix Maps Figures
Page 22: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Ms. Leslie Savage Railroad Commission of Texas Oil and Gas Division 1701 North Congress P.O. Box 12967 Austin, TX 78711-2967 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Ms. Savage, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. met with your agency’s staff about in November 2011. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Import Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. Corpus Christi Liquefaction will be consulting with the Railroad Commission as necessary during the preparation of required permit applications. However, to assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000.

Page 23: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 24: Resource Reports Appendix Maps Figures
Page 25: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Ms. Celeste Brancel Texas Parks and Wildlife Department Habitat Assessment Program 4200 Smith School Road Austin, TX 78744-3291 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Ms. Brancel, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. met with your agency’s staff about in November 2011. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. To assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000. During that time the Texas Parks and Wildlife Departed conducted an impact review and provided that information to Cheniere on September 9, 2003.

Page 26: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 27: Resource Reports Appendix Maps Figures
Page 28: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Mr. Mike Wilson Director, Air Permits Division Texas Commission on Environmental Quality 12100 Park 35 Circle MC163 Austin, TX 78753 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Mr. Wilson: On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. met with you and your staff about in May 2011 and on December 20, 2011. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. Corpus Christi Liquefaction will be consulting with TCEQ as necessary during the preparation of required permit applications. However, to assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc. and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000 and TCEQ Air Permit Nos. 70741 and PSD-TX-1038.

Page 29: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 30: Resource Reports Appendix Maps Figures
Page 31: Resource Reports Appendix Maps Figures

Tetra Tech 7800 Shoal Creek Blvd.,Suite 253E/Austin, TX 78757

Tel 512.338.1667 Fax 512.338.1331 www.tetratech.com

January 12, 2012 Mr. Charles Maguire Texas Commission on Environmental Quality 12100 Park 35 Circle Austin, TX 78753 Subject: Corpus Christi Liquefaction Project San Patricio and Nueces Counties, Texas Dear Mr. Maguire, On behalf of Corpus Christi Liquefaction, LLC (“Corpus Christi Liquefaction”), a subsidiary of Cheniere Energy, Inc., we are contacting you regarding a new proposed project in the Corpus Christi, Texas area. Please note that this is in regards to the same project that representatives of Cheniere Energy, Inc. have previously met with TCEQ staff about. As a result of the improved outlook for domestic natural gas production, largely due to the shale gas-bearing formations in the United States, Corpus Christi Liquefaction is proposing to construct a 1.8 billion cubic feet per day (“Bcf/d”) natural gas liquefaction facility in San Patricio and Nueces Counties, Texas, to be known as the Corpus Christi Liquefaction Project (“Project”). The Project facility will have the capability both to liquefy surplus supplies of domestic natural gas for export to foreign markets as well as to receive and regasify limited quantities of imported liquefied natural gas (“LNG”). The Project will be located on the northeast shore of Corpus Christi Bay at the site of the previously authorized Cheniere Corpus Christi LNG Terminal. The attached figure shows the location of the proposed Project. The main component of the Project consists of three (3) liquefaction trains each capable of processing up to 700 MMcf/d of natural gas. The LNG will be stored in three 160,000 m3 full containment storage tanks. LNG will be imported/exported from the Terminal via LNG marine carriers transiting through the La Quinta Channel. This Project will not result in an increase in the number of ship transits already permitted for the Corpus Christi LNG Terminal. The Federal Energy Regulatory Commission (“FERC”) is the lead Federal agency for the Project. Corpus Christi Liquefaction submitted a request to FERC on December 13, 2011, to initiate the FERC’s formal pre-filing process and approval was granted by the FERC on December 22, 2011. This project has been assigned FERC Docket No. PF12-3-000. Corpus Christi Liquefaction anticipates filing its formal application with the FERC in August 2012, and FERC will then prepare an Environmental Assessment (“EA”) or an Environmental Impact Statement (“EIS”) to satisfy the National Environmental Policy Act (“NEPA”) process for the Project. Your agency will be invited to participate in the FERC pre-filing process for the Project. Corpus Christi Liquefaction will be consulting with TCEQ as necessary during the preparation of required permit applications. However, to assist Corpus Christi Liquefaction in preparing the FERC application and identifying possible issues to be addressed during the NEPA process, we are requesting information on resources under your agency’s jurisdiction that could be potentially affected by the Project. Please note that in 2003-2005 agency consultation, resource surveys, and a NEPA review were completed for the original LNG import terminal project proposed by Cheniere Energy, Inc., and its subsidiaries on the same site and which received authorization from the FERC under FERC Docket No. CP04-37-000.

Page 32: Resource Reports Appendix Maps Figures

TETRA TECH

Corpus Christi Liquefaction looks forward to working with your agency as it moves forward with development of this Project. We appreciate your assistance and thank in you advance for any help you can provide. A representative of Corpus Christi Liquefaction will be in contact with you soon to request a meeting to discuss the project in further detail. If you have questions or would like additional information about the Project please contact me at 512-338-1667 Ext: 134 ([email protected]), or John Scott, Project Manager, at 617-283-5169 ([email protected]). Sincerely,

Anne-Marie B. Griger, AICP Environmental Planner cc: Andrew Chartrand, Corpus Christi Liquefaction John Scott, Tetra Tech

Page 33: Resource Reports Appendix Maps Figures
Page 34: Resource Reports Appendix Maps Figures
Page 35: Resource Reports Appendix Maps Figures
Page 36: Resource Reports Appendix Maps Figures
Page 37: Resource Reports Appendix Maps Figures
Page 38: Resource Reports Appendix Maps Figures
Page 39: Resource Reports Appendix Maps Figures
Page 40: Resource Reports Appendix Maps Figures
Page 41: Resource Reports Appendix Maps Figures
Page 42: Resource Reports Appendix Maps Figures
Page 43: Resource Reports Appendix Maps Figures
Page 44: Resource Reports Appendix Maps Figures
Page 45: Resource Reports Appendix Maps Figures
Page 46: Resource Reports Appendix Maps Figures
Page 47: Resource Reports Appendix Maps Figures
Page 48: Resource Reports Appendix Maps Figures
Page 49: Resource Reports Appendix Maps Figures

January 2012

Corpus Christi Liquefaction, LLC Corpus Christi Liquefaction Project

APPENDIX 1C

ADJACENT LANDOWNERS

Privileged and Confidential – REMOVED FROM PUBLIC VERSION