respiratory protection against airborne infectious diseases
TRANSCRIPT
![Page 2: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/2.jpg)
California Aerosol Transmissible Disease Standard
• Became effective August 5, 2009
• Applies in most health care environments, including primary care
• Title 8, California Code of Regulations, Section 5199 http://www.dir.ca.gov/Title8/5199.html
![Page 3: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/3.jpg)
What is an Aerosol Transmissible Disease?
• A disease• That is transmitted by
aerosols (A gaseous suspension of fine solid or liquid particles)
![Page 4: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/4.jpg)
Disease Agents Act at Different Places in the Respiratory Tract
![Page 5: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/5.jpg)
Work settings covered by the ATD Standard
• Applies in health care, such as: – Hospitals– Long Term Health Care Facilities– Primary Care– Emergency Medical
• Applies in other high risk environments– Corrections– Homeless shelters– Drug treatment programs– First receiver– Laboratories
![Page 6: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/6.jpg)
Droplet vs. Airborne
• CDC divides diseases between those believed spread by:– large droplets that hit mucous membranes– small particles that are inhaled
• The ATD standard adopts this system although there is substantial evidence that many “droplet” diseases have an airborne route of transmission
• Default for novel diseases is airborne• At this time, respirators are required for H1N1
![Page 7: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/7.jpg)
Airborne Infectious Diseases
• Airborne spore release (e.g. anthrax) until decon
• Chickenpox (Varicella)• Highly pathogenic avian
influenza• Herpes zoster (varicella-
zoster, disseminated disease, per CDC)
• Measles (rubeola)
• Monkeypox
• SARS (Severe Acute Respiratory Syndrome)
• Smallpox• Tuberculosis
Cal/OSHA added:
• Novel or Unknown pathogen
• Any disease for which CDPH recommends AII
![Page 8: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/8.jpg)
Some Droplet diseases
• Diptheria• Influenza• Meningococcal
disease • Mumps• Mycoplasma
pneumonia
• Pertussis• Plague (pneumonic)• Rubella• SARS• Viral hemorrhagic
fevers • Diseases for which
CDPH recommends droplet precautions
![Page 9: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/9.jpg)
Is My Facility a “Referring Employer?”
• Screen persons for airborne infectious diseases (AirID).• Refer any person identified as a case or suspected case
of and Airborne Infectious Disease.• Not intend to provide further medical services to AirID
cases and suspected cases beyond first aid, initial treatment or screening and referral (no high hazard procedures on ATD cases)– Exception for novel pathogens – may maintain in facility if not
feasible to provide AII• Not provide transport, housing, or airborne infection
isolation to any person identified as an AirID case or suspected case, – Exceptions: may provide non-medical transport in the course of
a referral– May provide housing and isolation if AII not feasible for novel
pathogens
![Page 10: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/10.jpg)
Most Primary Care Operations are probably “referring employers.”
It is up to your facility to determine what services you can provide safely to patients and adopt appropriate precautions. Higher levels of care, may place you under the full scope of the standard.
![Page 11: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/11.jpg)
Referring Employers(subsection c)
• Source control, including early identification, cover cough, separation
• Screening procedures for airborne infectious diseases (AirIDs)– Medical– Non-medical (App. F)
• Have a system for timely referral (transfer) including getting information back
• Train employees• Respirators for:
– AirID cases not referred – AirID cases during initial treatment who are not using
source control, unless respirator use not feasible
![Page 12: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/12.jpg)
Referring Employers(subsection c)
• Have a system for exposure incidents, including precautionary removal, and TB surveillance
• Provide additional CDC recommended vaccines to HCWs (effective 9/1/10)
• Provide seasonal flu vaccine to all employees with occupational exposure
• Record keeping
![Page 13: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/13.jpg)
Protecting Health Care Workers in Non-Hospital Environments
• Early recognition of potential cases• Respiratory Hygiene• Separation of patients, limiting contact• Referral of patients needing airborne infection
isolation• Respiratory protection when appropriate• Hand hygiene, cleaning and disinfection of
surfaces• Vaccination and other medical follow-up• Training
![Page 14: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/14.jpg)
Why Do We Need Respirators• When people breathe, talk, sing, cough, or
sneeze moist warm droplets are emitted• The droplets are of various sizes• The droplets quickly lose water and become
smaller• Droplets of up to 100 microns may remain
airborne long enough to be inhaled• Influenza receptors are located throughout the
respiratory tract• Respirators, but not surgical masks, seal to the
face and force air to pass through filtering media
![Page 15: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/15.jpg)
When are Clinics required to use respirators
• While exposed to a patient who is a suspected or confirmed case of H1N1, TB or other AirID if patient not using source control measures, e.g.– if examining upper respiratory tract– if patient has bad cough and can’t use mask
• If high hazard procedures are performed on AirID patients (not referring employer)– As of September 1, 2010 higher levels of
protection are required for high hazard procedures
![Page 16: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/16.jpg)
Respirators and Surgical Masks
![Page 17: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/17.jpg)
Robert B. Lawrence, Matthew G. Duling, Catherine A. Calvert and Christopher C. Coffey , 'Comparison of Performance of Three Different Types of Respiratory Protection Devices', JOEH 3:9, 465 - 474
Respirators vs. Surgical Masks
Protection provided by device without fit-testing
Type of Device 5th percentile protection*
Elastomeric respirator 7.3
Filtering FacepieceN95
3.3
Surgical mask 1.2
*protection is outside concentration/inside concentration
![Page 18: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/18.jpg)
Derrick JL, Gomersall CD. Protecting healthcare staff from severe acute respiratory syndrome:filtration capacity of multiple surgical masks. In Journal of Hospital Infection (2005)59, 365-368.
Multiple Surgical Masks
![Page 19: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/19.jpg)
The Institute of Medicine Report
• Health care workers caring for H1N1 patients should use fit-tested N95 respirators or more effective respirators. – September 2009
![Page 20: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/20.jpg)
Respirator Basics
• Respirator use in health care is regulated by Section 5199 and Section 5144 (federal 29 CFR 1910.134)
• Requirements– Reduction of hazard with engineering and
administrative controls– Written program and designated administrator– Hazard assessment – Selection of appropriate, NIOSH approved
respirators
![Page 21: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/21.jpg)
Respirator Basics (cont)
• Medical Evaluation• Fit-testing (initial and periodic)• User procedures including seal check, cartridge
change, and procedures for IDLH• Procedures for storage, maintenance, cleaning
and disinfection• Training• Record Keeping• Program evaluation including employee
involvement
![Page 22: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/22.jpg)
Respirator Selection
![Page 23: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/23.jpg)
Air Purifying Respirators
• Air purifying respirators remove contaminants from the air being inhaled by the user– Conventional APR has negative pressure in the facepiece,
and is tight-fitting (generally)– Powered APR may have positive pressure, and may be a
hood, helmet, or tight-fitting facepiece
• N95 and other filters do not protect against gases and vapors
• APRs and PAPRs do not have an air source, and therefore can not be used in oxygen deficient atmospheres or if immediately dangerous to life or health (IDLH)
![Page 24: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/24.jpg)
N95 RespiratorsThese respirators only reduce particulates, not gases or vapors
![Page 25: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/25.jpg)
Elastomeric FacepiecesCartridges are available for particulates only, and for specific levels of gases or vapors.
![Page 26: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/26.jpg)
Powered Air-PurifyingRespirators(PAPR)
![Page 27: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/27.jpg)
Atmosphere Supplying Respirators
• Provide their own source of air (compressor, air tank, or portable air tank)
• Can be positive or (rarely) negative pressure
• Can be tight-fitting facepiece, or hood or helmet
• Generally do not filter air being exhaled
![Page 28: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/28.jpg)
SCBA
![Page 29: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/29.jpg)
Filtering Facepiece Respirators
• Nose bridge sealing surface– Adjustable or fixed
• Chin sealing surface• Straps and attachment• Also fluid resistant (“surgical
N95”)• Filter – N, R, or P, 95, 99 or
100• Exhalation Valve• Fold Flat• Latex free• Fit
![Page 30: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/30.jpg)
Respirator Designs Vary
![Page 31: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/31.jpg)
Respirator Designs Vary
![Page 32: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/32.jpg)
Medical Issues with Respirator Use
• Increased resistance to air flow• Increased dead space volume
• Increased CO2
• Heat effects, particularly if used in conjunction with other PPE
• Physical work, ergonomics – particularly with SCBA
• Claustrophobia• Limits to communications
![Page 33: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/33.jpg)
Confidential Medical Evaluations • Medical Evaluation must have the content of the
questionnaire in Section 5144, Appendix C– ATD standard permits the use of a shorter
questionnaire in Section 5199, Appendix B
• Questionnaire is available on many websites• Must be evaluated by a PLHCP who can order
additional tests• A “yes” answer to any specified question
requires “further evaluation”• No interval is specified for re-evaluation – the
PLHCP and employer should specify
![Page 34: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/34.jpg)
Fit-testing
• The purpose of fit-testing is to ensure that a selected respirator will provide the required protection factor.
• Allowed fit-test methods are in Appendix A to Section 5144.
• Qualitative fit-tests use a challenge agent: – bitrex, saccharine, irritant smoke, or isoamyl acetate.
• Quantitative fit-tests measure leakage:– Generated aerosol, ambient aerosol, controlled
negative pressure.
![Page 35: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/35.jpg)
Qualitative Fit Test
![Page 36: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/36.jpg)
Quantitative Fit Test
![Page 37: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/37.jpg)
Do N95’s need to be fit-tested?
1996 NIOSH laboratory study of 25 subjects with 21 models of N95s found
• Without fit-testing, the average protection factor for all subjects using a respirator was 3.
• By selecting out bad fits, using a fit-test, the average protection factor was 25
• Only four models passed a fit-test for the majority of participants. Three did not pass the fit-test for any participant. Laboratory Performance Evaluation of N95 Filtering Facepiece Respirators, 1996. MMWR Morb Mortal Wkly Rep. 1998 Dec 11;47(48):1045-9.
![Page 38: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/38.jpg)
Effect of Fit-testing N95
Type Geometric mean without fit-test
5th %ilew/o /FT
5th %ile pass bitrex
5th %ile pass companion
Filtering facepiece
20.4 3.3 7.9 20.5
Source: Robert B. Lawrence, Matthew G. Duling, Catherine A. Calvert and Christopher C. Coffey , 'Comparison of Performance of Three Different Types of Respiratory Protection Devices', JOEH 3:9, 465 - 474
![Page 39: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/39.jpg)
Additional Fit Tests
• To be provided if employee requests additional fit test
• If employee has weight gain or loss, facial changes (such as surgery or dental work) that may effect fit
• At least annually– Exception in Section 5199 for non-high
hazard, permits biennial until 1/1/2014 – Must provide Appendix G info in alternate
years
![Page 40: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/40.jpg)
N95 User Procedures
• User seal check difficult to perform on filtering facepiece respirators
• Can not be used in atmospheres “immediately dangerous to life or health”
• Will not protect against gases or vapors, only particles (including mists)
• Change respirator (filtering facepiece) or cartridge when breathing becomes more difficult or if dirty, wet, etc.
![Page 41: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/41.jpg)
What’s Wrong with this Picture?
• Respirators do not work if they do not seal to the face.
• Facial hair must not interfere with the seal.
• Straps must be directly seated on the head, in this case above and below the ear
![Page 42: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/42.jpg)
N95 Maintenance, Storage, Inspection
• Every respirator should be inspected prior to putting it on, to make sure the straps are okay, it is not torn, deformed, dirty, etc.
• Generally filtering facepiece respirators used against infectious particles should be disposed each time they are removed
• If shortage prevents disposal, employer should have storage and re-donning procedures, including procedures for handling respirator to prevent contamination
• No respirator should be put on if it is torn, wet, dirty, or unable to form a facepiece seal
![Page 43: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/43.jpg)
Initial and Annual TrainingRequired training elements
• Why the respirator is necessary and how improper fit, usage, or maintenance can compromise respirator protective effect ;
• Limitations and capabilities of the respirator• Emergency use and what to do it respirator
malfunctions • How to inspect, put on and remove, use, and
check the seals of the respirator; • maintenance and storage of the respirator; • Medical signs and symptoms that may limit or
prevent the effective use of respirators; and • General requirements of regulation
![Page 44: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/44.jpg)
Program Review
• At least annual
• Consult with affected employees
Record Keeping• Medical evaluations per 3204
• Most recent fit-test
• Appendix G to 5199
• Current respirator program made available
![Page 45: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/45.jpg)
Help with Respirators
• Cal/OSHA consultation:1(800) 963-9424 • California Association of Health Facilities,
model program http://www.cahfdownload.com/cahf/dpp/CAHF_ModelRespiratoryProtectionProgram.pdf
• Occupational Health Branch train-the-trainer programs -- TBA
• Respirator manufacturers and distributors
• Workers’ comp insurance carriers
![Page 46: Respiratory Protection Against Airborne Infectious Diseases](https://reader034.vdocument.in/reader034/viewer/2022052622/559711d01a28ab2f108b4608/html5/thumbnails/46.jpg)
Find Cal/OSHA on the Web
• Cal/OSHA ATD standard: – http://www.dir.ca.gov/Title8/5199.html
• Advisory committee webpage:– http://www.dir.ca.gov/dosh/DoshReg/advisory
_committee.html
• Respiratory protection regulation– http://www.dir.ca.gov/Title8/5144.html
• Respiratory Protection in the Workplace– http://www.dir.ca.gov/dosh/dosh_publications/
respiratory.pdf