restoring profitability to cpap - mysleep · restoring profitability to cpap 3b™ medical, inc....

2
Restoring Profitability to CPAP 3B™ Medical, Inc. 799 Overlook Drive Winter Haven, FL 33884 (863) 226-6285 [email protected] www.3Bproducts.com Advanced Clinical Efficacy Reporting QR Coded Data for Smartphone Upload Cellular and WiFi Wireless Data Reporting Innovative Humidifier Design Provides Maximum Efficiency Dimensions: 170 × 196 × 118 mm 290x196x134 mm (with Integrated Heated Humidifier) Weight: <1.5 KG <2.5KG (with Integrated Heated Humidifier) Environmental: Operating Transport and Storage Temperature 5 to 35°C -25 to 70°C Relative 93% 93% Humidity Non-condensing Non-condensing Atmospheric Pressure 760 to 1060 hPa 760 to 1060 hPa Standards Compliance: IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment IEC 60601-1-2 Electromagnetic Compatibility ISO 17510 Sleep Apnea Breathing Therapy ISO 8185 General Requirements for Humidification Systems Electrical: AC Power Consumption: 100 - 240V AC, 50/60Hz, Max 95VA Type of Protection Against Electric Shock: Class II Equipment Degree of Protection Against Electric Shock: Type BF Applied Part Degree of Protection Against Ingress of Water: Drip Proof, IPX1 Mode of Operation: Continuous Luna ® Pressure Function Auto Pressure Luna Auto 4-20cmH 2 O Auto, CPAP YES Luna CPAP 4-20cmH 2 O CPAP NO Pressure CPAP 4 to 20 cmH 2 O ±1 cmH 2 O* Ramp Duration 0 to 60 minutes ±10% of the setting * Dynamic pressure accuracy is ±1 cmH 2 O measured at the patient end of the circuit. Static pressure accuracy is ±0.5 cmH 2 O measured at the patient end of the circuit. L7000 E-20C Luna CPAP + Humidifier L8000 E-20A Luna Auto-CPAP + Humidifier WL-100 Luna WiFi Module L4510 Luna Replacement Water Chamber L1020BX Replacement Air Filter WL-200 Luna Cellular GPRS Module with WiFi

Upload: others

Post on 19-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Restoring Profitability to CPAP - Mysleep · Restoring Profitability to CPAP 3B™ Medical, Inc. 799 Overlook Drive Winter Haven, FL 33884 (863) 226-6285 info@3bproducts.com

R e s t o r i n g P r o f i t a b i l i t y t o C P A P

3B™ Medical, Inc.799 Overlook Drive

Winter Haven, FL 33884

(863) [email protected]

Advanced Clinical Efficacy Reporting

QR Coded Data for Smartphone Upload

Cellular and WiFi Wireless Data Reporting

Innovative Humidifier Design Provides Maximum Efficiency

Dimensions: 170 × 196 × 118 mm290x196x134 mm (with Integrated Heated Humidifier)

Weight: <1.5 KG<2.5KG (with Integrated Heated Humidifier)

Environmental: Operating Transport and StorageTemperature 5 to 35°C -25 to 70°CRelative ≤ 93% ≤ 93%Humidity Non-condensing Non-condensingAtmosphericPressure 760 to 1060 hPa 760 to 1060 hPa

Standards Compliance:IEC 60601-1 General Requirements for Safety of Medical Electrical EquipmentIEC 60601-1-2 Electromagnetic CompatibilityISO 17510 Sleep Apnea Breathing TherapyISO 8185 General Requirements for Humidification Systems

Electrical:AC Power Consumption: 100 - 240V AC, 50/60Hz, Max 95VAType of Protection Against Electric Shock: Class II EquipmentDegree of Protection Against Electric Shock: Type BF Applied PartDegree of Protection Against Ingress of Water: Drip Proof, IPX1

Mode of Operation: ContinuousLuna® Pressure Function Auto PressureLuna Auto 4-20cmH2O Auto, CPAP YESLuna CPAP 4-20cmH2O CPAP NOPressureCPAP 4 to 20 cmH2O ±1 cmH2O*

Ramp Duration 0 to 60 minutes ±10% of the setting * Dynamic pressure accuracy is ±1 cmH2O measured at the patient end of the circuit. Static pressure accuracy is ±0.5 cmH2O measured at the patient end of the circuit.

L7000 E-20C Luna CPAP + Humidifier

L8000 E-20A Luna Auto-CPAP + Humidifier

WL-100 Luna WiFi Module

L4510 Luna Replacement Water Chamber

L1020BX Replacement Air Filter

WL-200 Luna Cellular GPRS Module

with WiFi

Page 2: Restoring Profitability to CPAP - Mysleep · Restoring Profitability to CPAP 3B™ Medical, Inc. 799 Overlook Drive Winter Haven, FL 33884 (863) 226-6285 info@3bproducts.com

Luna Cellular Module

iCode® with IVR iCode® with Interactive

Voice Recognition is just one

more way 3B™’s iCodeConnect™

is helping companies return

profitability to their bottom line. With IVR,

you have the peace of mind knowing that

no matter what the challenges other forms of

data capture may present, you can breathe

easy knowing IVR is there to help.

WiFiWiFi provides reliable, “real time” data from

your Luna® devices at no cost. Luna® WiFi

allows you and your referrals to capture and

access your patient’s detailed compliance

data whenever it is needed. And because

it is typically free of transmission fees, it is the

modality of choice for today’s

cost challenges.

SD CardAll 3B™ products come standard with SD Card technology. With iCodeConnect™, no special card

reader, software or other proprietary tools need to be installed. Simply upload your patient’s device SD

Card into iCodeConnect™ and your patient’s detailed report is at your fingertips, safely and securely.

QR CodeWith iCode-QR, any smart

device can simply “scan”,

capture and automatically upload

patient sleep data with the use of the

free smart phone app. QR and the app

are always free and instantly upload your

patient data. And because iCodeConnect™

is cloud based, you can access your

patient’s data anytime, anywhere.

Because iCodeConnect™ is cloud based, you can access your patient’s data anytime, anywhere.

CellularCellular modem offers the ability to capture

your patient’s necessary compliance data

from almost anywhere, all the time. 3B™

offers one of the lowest cost cellular options

in the market and provides detailed data at

your fingertips any time you

need it.

QR Code

Wi-Fi

Interactive VoiceRecognition

SD Card

iCodeConnect™

Luna

CellularModem