results of testing the aedc 5-mw segmented ...aedc-tr-75-127 .~t~ [ ja[~ o v ,,,,r.results of...

37
AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r. RESULTS OF TESTING THE AEDC 5-MW SEGMENTEDARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND TUNNEL FACILITY ARNOLD ENGINEERING DEVELOPMENT CENTER AIR FORCE SYSTEMS COMMAND ARNOLD AIR FORCE STATION, TENNESSEE 37389 November 1975 Final Report for Period October 10, 1974 - February 27, 1975 Approved for publ,c release; distribution unl,m=ted. ~'- ,"~=3 k_~..'-.J ,=',. . ., , , .~..., ,,, j "/ ~ .. ".;, Prepared for DIRECTORATE OF TECHNOLOGY (DY) ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AIR FORCE STATION, TENNESSEE 37389 ... '.,i." : ., *-~b .

Upload: others

Post on 04-Sep-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127 .~T~

[

JA[~ O v ,,,,r.

RESULTS OF TESTING THE AEDC

5-MW SEGMENTED ARC HEATER

AT PRESSURES UP TO 171 ATM

PROPULSION WIND TUNNEL FACILITY ARNOLD ENGINEERING DEVELOPMENT CENTER

AIR FORCE SYSTEMS COMMAND ARNOLD AIR FORCE STATION, TENNESSEE 37389

November 1975

Final Report for Period October 10, 1974 - February 27, 1975

Approved fo r publ ,c release; d i s t r i bu t ion unl,m=ted.

~'- ,"~=3 k_~..'-. J ,=',. . ., ,

, .~..., ,,, j " / ~ . . " . ; ,

Prepared for

DIRECTORATE OF TECHNOLOGY (DY) ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AIR FORCE STATION, TENNESSEE 37389

• . . . •

' . , i . " : • . , * - ~ b .

Page 2: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

• ° • ~ .

- i

NOTICES

When U. S. Government drawings specifications, or other data are used for any purpose other than a definitely related Government procurement operation, the Government thereby incurs no responsibility nor any obligation whatsoever, and the fact that the Government may have formulated, furnished, or in any way supplied the said drawings, specifications, or other data. is not to be regarded by implication or otherwise, or in any manner licensing the holder or any other person or corporation, or conveying any rights or permission to manufacture, use, or sell any patented invention that may in any way be related thereto.

Qualified users may obtain copies of this report from the Defense Documentation Center.

References to named commercial products in this report are not to be considered in any sense as an endorsement of the product by the United States Air Force or the Government.

This report has been reviewed by the Information Office (e l ) and is releasable to the National Technical Information Service (NTIS). At NTIS, it will be available to the general public, including foreign nations.

APPROVAL STATEMENT

This technical report has been reviewed and is approved for publication.

FOR THE COMMANDER

MELVIN L. GUIOU Captain. USAF Rc~earch & Development

Division l)ircctoratc of Technology

o

ROBERT O. 'DIETZ Director of Technology

Page 3: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

UNCLASSIFIED I REPORT DOCUMENTATION PAGE '1 REPORT NUMBER 12. GOVT ACCESSION NO

AEDC-TR-75-127 L 4. T ITLE (and SubrilfeJ

RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM

? AU TNOR(s,t

Dennis D. Horn and Richard T. Smith, ARO, Inc.

9. PERFORMING ORGANIZATION NAME AND ADDRESS

A r n o l d E n g i n e e r i n g D e v e l o p m e n t C e n t e r (DY) A r n o l d A i r F o r c e S t a t i o n , T e n n e s s e e 37389

I i CONTROLLING OFFICE NAME AND ADDRESS

A r n o l d E n g i n e e r i n g D e v e l o p m e n t C e n t e r (DYFS) A r n o l d A i r F o r c e S t a t i o n ~ T e n n e s s e e 37389 14 MONITORING AGENCY NAME & ADDRESS(it dlH, rmt from C ~ f ~ t | l n O Ol f l©~

R E A D I N S T R U C T I O N S B E F O R E C O M P L E T I N G FORM

3. REClPIENT'S CATALOG NUMBER

5. TYPE OF REPORT & PERIOD COVERED

F i n a l R e p o r t - O c t o b e r 10 1 9 7 4 - F e b r u a r y 27, 1975

S. PERFORMING ORG. REPORT NUMBER

8 CONTRACT OR GRANT NUMBER(m)

10. PROGRAM ELEMENT. PROJECT. TASK AREA & WORK UNIT NUMBERS

Program Element 65807F

iz. REPOR!.O~TE November 1975_

13. NUMBER OF PAGES

34 15 SECURITY CLASS• (of Ihla tepor~

UNCLASSIFIED

ISa. DECL ASSiFIC ATION/DOWNGRADING SCNEDUL.E N/A

16 DISTRIBUTION STATEMENT (of whim Repor~

A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n u n l i m i t e d .

17 DISTRIBUTION STATEMENT (of fhe ebalract entered in BJock 20, lit dltferent born Repott,t

18 SUPPLEMENTARY NOTES

Available in DDC

119 K EY WORDS (ContJnue on revetae elde I ! neceeaery end identi fy by block numbeO

t e s t m e t h o d s 5-MW s e g m e n t e d a r c

h e a t e r p r e s s u r e s ( c h a m b e r )

h i g h p r e s s u r e e n t h a l p y a r c h e a t e r s

20 ABSTRACT (Can t l~e on rev~me ml~ |1 neceaaa~ and tden t i~ by block numbe~

The r e s u l t s o f t e s t i n g a n o m i n a l 5-MW s e g m e n t e d ( c o n s t r i c t o r - c h a n n e l t y p e ) a r c h e a t e r a r e p r e s e n t e d . The h e a t e r was o p e r a t e d a t c h a m b e r p r e s s u r e s up t o 171 arm and power i n p u t s t o n e a r l y 4 MW u s i n g a i r a s t h e t e s t g a s . B u l k e n t h a l p i e s r a n g e d f r o m a b o u t 5 , 7 0 0 B t u / l b a t 60 a rm t o 3 , 5 0 0 B t u / l b a t 153 a rm. The n o z z l e e x i t f l o w was s u r v e y e d w i t h a null-polnt c a l o r i m e t e r , p r e s s u r e , and e n t h a l p y p r o b e s . P e r f o r m a n c e c o m p a r i s o n s a r e made b e t w e e n t h e

i

DD FORM , jAN ?3 1 4 7 3 EO, T I O . OF , ROY ss is OBSOLETE

UNCLASSIFIED

Page 4: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

UNCLASSIFIED

20 . ABSTRACT ( C o n t i n u e d )

s e g m e n t e d a n d o t h e r t y p e s o f a r c h e a t e r s a n d w i t h an a n a l y t i c a l c o r r e l a t i o n p r o g r a m . D e t a i l e d t e s t a n d d a t a s u m m a r i e s a r e p r e s e n t e d .

AF$C k e l ~ l d k f ' | T e ~

UNCLASSIFIED

Page 5: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-TR -75-127

PREFACE

The work reported herein was conducted by the Arnold Engineering Development Center (AEDC), Air Force Systems Command (AFSC), under Program Element 65807F. The results presented in this report were obtained by ARO, Inc. (a sub- sidiary of Sverdrup & Parcel and Associates, Inc.), contract operator of AEDC, AFSC, Arnold Air Force Station, Tennessee. The work was done under ARO Project No. PS2S-21A. The authors of this report were Dennis D. Horn and Richard T. Smith, ARO, Inc. The manuscript (ARO Control No. ARO-PWT- TR-75-85) was submitted for publication on June 20, 1975.

Page 6: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

1.0

2 . 0

3 . 0

4 . 0

CONTENTS

INTRODUCTION . . . . . . . . . . . . . . . . .

TEST FACILITY AND PROCEDURE 2.1 Electric Power and Other Utilities . . . 2.2 Instrumentation . . . . . . . . . . . . . 2.3 Arc Heater . . . . . . . . . . . . . . . 2.4 Procedure . . . . . . . . . . . . . . . .

TEST DESCRIPTION AND RESULTS 3.1 Run Summary . . . . . . . . . . . . . . . 3.2 Arc Heater Data . . . . . . . . . . . . . 3.3 Model Data 3 . 4 C o m p a r i s o n o e r a c

O t h e r A r c H e a t e r s . . . . . . . . . . . .

CONCLUDING REMARKS . . . . . . . . . . . . . .

REFERENCES . . . . . . . . . . . . . . . . . .

P a g e

5 7 7

10

ii 15 22

25

25

26

I L LUSTRATIONS

Figure

1 . C h a r a c t e r i s t i c s o f t h e AEDC N o m i n a l 5-MW P o w e r S u p p l y . . . . . . . . . . . . . . . . .

2 . 5-MW S e g m e n t e d A r c H e a t e r . . . . . . . . . . .

3 . I n i t i a l 5-MW S e g m e n t e d A r c H e a t e r C o n f i g u r a t i o n . . . . . . . . . . . . . . . . .

4 . V a r i o u s S e g m e n t D e s i g n s u s e d o n t h e 5-MW S e g m e n t e d A r c H e a t e r a . O r i g i n a l EOS C o n f i g u r a t i o n . . . . . . . . b . AEDC W e l d e d C o n s t r u c t i o n

st;u;t o . . . . . c . AEDC S i l v e r - S o l d e r e d C o n . . . . .

5 . 5-MW S e g m e n t e d A r c H e a t e r w i t h L i n d e - T y p e T u b u l a r A n o d e A s s e m b l y . . . . . . . . . . . .

6 . P r o t o t y p e S e g m e n t C o n f i g u r a t i o n . . . . . . . .

7 . 5-MW S e g m e n t e d A r c H e a t e r P e r f o r m a n c e D a t a . .

8 . C o m p a r i s o n o f M e a s u r e d a n d C a l c u l a t e d V a l u e s o f A r c H e a t e r P a r a m e t e r s a . B u l k E n t h a l p y . . . . . . . . . . . . . . . b . A r c V o l t a g e . . . . . . . . . . . . . . . . c . T o t a l P r e s s u r e . . . . . . . . . . . . . .

6

7

8

9 9 9

13

14

15

17 18 18

Page 7: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-T R-75-127

F i g u r e P a g e

9 . C o m p a r i s o n o2 A r c H e a t e r D a t a w i t h S o n i c F l o w E q u a t i o n . . . . . . . . . . . . . . 19

1 0 . C h a n n e l S e g m e n t W a l l C r o s s S e c t i o n . . . . . . 20

1 1 . A v e r a g e C h a n n e l W a l l H e a t F l u x . . . . . . . . 21

1 2 . M e a s u r e d a n d P r e d i c t e d V o l t a g e G r a d i e n t • . . 22

1 3 , E n d u r a n c e Run . . . . . . . . . . . . . . . . . 23

1 4 . I m p a c t P r e s s u r e P r o f i l e s a t N o z z l e E x i t . . . . 23

1 5 . T o t a l E n t h a l p y P r o f i l e s a t N o z z l e E x i t . . . . 24

1 6 . N o z z l e E x i t H e a t - T r a n s f e r P r o f i l e s f o r t h e E n d u r a n c e Run . . . . . . . . . . . . . . . 25

TABLES

1 . 5-MW S e g m e n t e d A r c D a t a S u m m a r y . . . . . . . . 27

2 . D e s c r i p t i v e T e s t S u m m a r y f o r FY75 . . . . . . . 28

NOMENCLATURE . . . . . . . . . . . . . . . . . . . . 34

4

Page 8: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

1.0 INTRODUCTION

I n 1967 , t h e A r n o l d E n g i n e e r i n g D e v e l o p m e n t C e n t e r (AEDC), A i r F o r c e S y s t e m s Command (AFSC), c o n t r a c t e d w i t h E l e c t r o - O p t i c a l S y s t e m s , I n c . (EOS) t o s t u d y a n d d e v e l o p an u n t r a h i g h - p r e s s u r e a r c h e a t e r ( R e f s . 1 and 2 ) . T h i s e f f o r t r e s u l t e d i n t h e d e l i v e r y o f a c o n s t r i c t e d - c h a n n e l , s e g m e n t e d a r c h e a t e r t o AEDC i n 1 9 6 9 . The s p e c i f i c g o a l f o r t h i s d - c a r c h e a t e r was t o h e a t a i r t o 3 , 8 3 0 B t u / l b b u l k e n t h a l p y a t 200 arm c h a m b e r p r e s s u r e w i t h a p o w e r i n p u t o f 5 MW. The r e s u l t s o f o p e r a t i n g t h i s h e a t e r t h r o u g h J u n e 1970 a t AEDC a r e p r e s e n t e d i n R e f . 3 . V a r i o u s h a r d w a r e p r o b l e m s p r e v e n t e d s t a b l e o p e r a t i o n a b o v e 25 a rm .

This heater was extensively modified and experimental efforts were resumed during Fiscal Year 1972 (FY72). There- after, this modified heater was referred as the 5-MW Segmented Arc Heater. The specific objectives were to operate the heater on air at chamber pressures of 25, 50, 80, and I00 atm, and obtain steady-state bulk enthalpies at arc current levels of 400, 500, and 600 amp. The results of operating the heater during FY72, 73, and 74 are presented in detail in Ref. 4. The highest pressure at which the heater was tested during that test series was 104 atm.

The r e s u l t s o f t e s t i n g t h e 5-MW s e g m e n t e d a r c h e a t e r d u r i n g FY75 a r e r e p o r t e d h e r e i n . The s p e c i f i c o b j e c t i v e s o f t h i s e f f o r t w e r e t o o b t a i n p e r f o r m a n c e d a t a a t c h a m b e r p r e s s u r e s up t o 150 a t m , t o make an e n d u r a n c e r u n up t o 1 min l o n g a t a p r e s s u r e l e v e l o f a t l e a s t 100 a rm, a n d t o p r o v i d e h a r d w a r e d e s i g n c r i t e r i a f o r a l a r g e - s c a l e s e g m e n t e d a r c h e a t e r . The l o n g - r a n g e o b j e c t i v e s o f t h e 5-MW s e g m e n t e d a r c r e s e a r c h e f f o r t w e r e t o p r o v i d e p e r f o r m a n c e and d e s i g n d a t a i n s u p p o r t o f t h e l a r g e - s c a l e s e g m e n t e d h e a t e r a n d t o u p g r a d e and make a v a i l a b l e an o p e r a t i o n a l v e r s i o n o f t h e 5-MW s e g m e n t e d a r c h e a t e r f o r u s e r a b l a t i o n t e s t i n g and i n - h o u s e r e s e a r c h .

2.0 TEST FACILITY AND PROCEDURE

The tests were conducted in the 5-MW Research Arc Heater Unit of the Propulsion Wind Tunnel Facility (PWT), AEDC.

2.1 ELECTRIC POWER AND OTHER UTILITIES

E l e c t r i c p o w e r was s u p p l i e d t o t h e a r c h e a t e r t h r o u g h a s e r i e s o f t r a n s f o r m e r s and an i g n i t i o n r e c t i f i e r . The

Page 9: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

characteristics of this d-c supply are shown in Fig. I. Ballast resistance up to 9.3 ohms was added as necessary to provide current control and improve arc stability. High- pressure air (up to 4,000 psia) was supplied by the AEDC von K~rman Gas Dynamics Facility (VKF) either from a storage bottle or directly from compressors, through a pressure control and metering station. Demineralized cooling water was supplied to the arc heater by two centrifugal pumps, e a c h r a t e d a t 1 2 0 gpm a t 1 , 2 0 0 p s i g . Raw w a t e r f o r n o z z l e c o o l i n g w a s s u p p l i e d b y a c e n t r i f u g a l pump r a t e d a t 2 0 0 gpm a t 1 , 2 0 0 p s i g .

I0000

9000

9 0 0 0

7000

6000

. 5000 I,,

0 > 4000

ZI000

2000

I 0 0 0

0 0 I00 2o0 3o0 4oo 500 600 700 8oo

CURRENT, omp

Figure 1. Characteristics of the A E D C nominal 5-MW power supply.

Page 10: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-TR -75-127

2.2 INSTRUMENTATION

S t r a i n - g a g e t r a n s d u c e r s , t h e r m o c o u p l e s , v o l t a g e d i v i d e r s , c u r r e n t t r a n s d u c e r s , a n d t u r b i n e - t y p e f l o w m e t e r s w e r e s e n s o r s f o r t h e p r e s s u r e s , t e m p e r a t u r e s , a r c v o l t a g e a n d c u r r e n t , a n d c o o l i n g - w a t e r f l o w s . T h e s e p a r a m e t e r s w e r e r e c o r d e d on s t r i p c h a r t r e c o r d e r s f o r s t e a d y - s t a t e v a l u e s ; t r a n s i e n t a n d r e d u n - d a n t p a r a m e t e r s w e r e r e c o r d e d on o s c i l l o g r a p h s . A i r m a s s f l o w r a t e was m e a s u r e d u s i n g a c h o k e d v e n t u r i w h i c h w a s c a l i b r a t e d b y f l o w i n g a i r i n t o a t a n k a n d w e i g h i n g on p r e c i s i o n s c a l e s . C o n t r o l r o o m d a t a w e r e o b t a i n e d f r o m p a n e l m e t e r s a n d s t r i p c h a r t r e c o r d e r s . C l o s e d - c i r c u i t t e l e v i s i o n w a s u s e d t o m o n i - t o r t h e a r c h e a t e r a n d m o d e l s d u r i n g o p e r a t i o n .

Model instrumentation included a 0.25-in. nose radius null-point calorimeter, an impact pressure probe, anda total enthalpy probe (Ref. 5). These probes were swept through the heater effluent consecutively, using a five-position linear model injection system (Ref. 6). Model tips were positioned 0.i in. downstream of the nozzle exit, and the sweep rate was approximately 32 in./sec. Surveillance of the heater, models, and effluent was done by the use of high-speed motion pictures.

2.3 ARC HEATER

The initial arc heater configuration used for this test series is shown in the photograph in Fig. 2 and the schematic in Fig. 3. Operating configurations prior to FY75 are

Figure 2. 5-MW segmented arc heater.

Page 11: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

OO

H20 I

H20 (

I nsp~ Plate

End Plate Downstream Air oi l Assembly Injection Ring- Segments 1Air Channel Segments

(Constrictor /h ~--Diam = 0.934 in.) ~

%

Jlated Assembly Bolts

--L;amooe Assembly , .

r uownslream Segments

bDIn , : • . .

.L;OI I ~

D* - 0.21.5 in.

DFIow

m ID

..n

.L, 0 1

,.,,j

Tap

Figure 3. Initial 5-MW segmented arc heater configuration.

Page 12: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

described in detail in Ref. 4. The heater consisted of a constrictor channel made up of water-cooled copper segments separated by 0.081-in.-thick boron nitride insulators. The channel had an internal diameter of 0.934 in. and consisted of 55 segments, including three tapered segments and an air injection ring at each end. The straight portion of the channel contained ten AEDC-welded segments 0.187 in. wide and 37 AEDC-silver-soldered segments 0.250 in. wide (see Fig. 4).

Nots All Dimensions in Inches

• -1 ~'O. 18"/ r~

Silver- ~'-'

Solder . ,

L . . . . .

f j

r, r #

r #

a. Original EOS configuration

-4 I-.-O. 187

W0:n' t

b. AEDC welded construction

-4 I-0.250

E t ~Silver-Solder

Joint Z

O. 934 Diam

ol

c. AEDC silver- soldered construction

Figure 4. Various segment designs used on the 5-MW segmented arc heater.

A r i n g e l e c t r o d e l o c a t e d a t t h e u p s t r e a m e n d o f t h e c h a n n e l s e r v e d a s t h e a n o d e . A m a g n e t i c c o i l , e n c a p s u l a t e d i n p l a s t i c a n d c o n s i s t i n g o f e i g h t t u r n s o f s q u a r e c o p p e r t u b i n g , f o r m e d t h e e x t e r n a l p a r t o f t h e e l e c t r o d e r i n g a s s e m b l y . A new c a t h o d e a s s e m b l y l o c a t e d a t t h e d o w n s t r e a m e n d o f t h e c h a n n e l c o n t a i n e d a s h o r t t u b u l a r e l e c t r o d e s u r r o u n d e d b y a h a n d - w o u n d m a g n e t i c c o i l o f a p p r o x i m a t e l y 15 t u r n s o f i n s u l a t e d , w a t e r - c o o l e d c o p p e r t u b i n g .

Page 13: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

T h e c o i l s w e r e e l e c t r i c a l l y c o n n e c t e d i n s e r i e s w i t h t h e a r c c o l u m n ; t h e p o l a r i t y w a s s e l e c t e d t o a u g m e n t t h e a i r s w i r l a n d s t i m u l a t e r o t a t i o n o f t h e a r c t e r m i n a t i o n o n t h e e l e c t r o d e s . T h e h e a t e r w a s o p e r a t e d w i t h r e v e r s e d p o l a r i t y t h r o u g h o u t t h e t e s t s e r i e s , i . e . , t h e a n o d e w a s t h e u p s t r e a m e l e c t r o d e . T h e a x i a l d i s t a n c e b e t w e e n e l e c t r o d e s w a s a p p r o x i m a t e l y 18 i n .

F o u r u p s t r e a m s e g m e n t s w e r e p o s i t i o n e d b e t w e e n t h e a n o d e a n d e n d p l a t e a s s e m b l y , e a c h e l e c t r i c a l l y i n s u l a t e d w i t h b o r o n n i t r i d e s p a c e r s . T h e s e s e g m e n t s , c o u p l e d w i t h t a n g e n t i a l a i r i n j e c t i o n a t t h e e n d p l a t e l i n e r , p r e v e n t e d a r c a t t a c h m e n t o n t h e e n d p l a t e . Two d o w n s t r e a m s e g m e n t s p r o v i d e d a t r a n s i t i o n s e c t i o n f o r t h e f l o w e n t e r i n g t h e n o z z l e t h r o a t . T h e c o n i c a l n o z z l e h a d a 0 . 2 1 5 - i n . t h r o a t d i a m e t e r a n d a 0 . 4 0 0 - i n . e x i t d i a m e t e r . A i r w a s i n t r o d u c e d a t t h e u p s t r e a m a n d d o w n s t r e a m a i r i n j e c t i o n r i n g s a n d a t t h e e n d p l a t e l i n e r i n v a r i o u s r a t i o s c o n t r o l l e d b y o r i f i c e s i n t h e s u p p l y l i n e s a s i n d i c a t e d i n T a b l e 2 . S w i r l d i r e c t i o n f o r a l l a i r s t a t i o n s w a s c l o c k - w i s e l o o k i n g d o w n s t r e a m .

T h e c o n f i g u r a t i o n c h a n g e s m a d e t o t h e h e a t e r a t t h e b e g i n n i n g o f t h i s t e s t s e r i e s w e r e a s f o l l o w s :

1 . T h e e n d p l a t e a s s e m b l y w a s m o d i f i e d t o i n c l u d e a n i n s p e c t i o n p l a t e . T h i s a l l o w e d t h e i n n e r l i n e r t o b e r e m o v e d f o r i n - p l a c e i n s p e c t i o n o f t h e u p s t r e a m p o r t i o n o f t h e a r c h e a t e r .

2 . A new c a t h o d e a s s e m b l y ( d e s c r i b e d a b o v e ) w a s i n s t a l l e d t o p r o v i d e a m o r e d u r a b l e e l e c t r o d e s u r f a c e , t o l o w e r e r o s i o n r a t e s , a n d t o a l l o w i n - p l a c e i n s p e c t i o n o f t h e d o w n s t r e a m e n d o f t h e h e a t e r . T h e f l a n g e o n t h e u p s t r e a m e n d o f t h e c a t h o d e a s s e m b l y w e r e u s e d t o h o l d t h e h e a t e r t o g e t h e r w h i l e t h e n o z z l e a n d d o w n s t r e a m s e g m e n t s w e r e r e m o v e d f o r i n s p e c t i o n .

Subsequent modifications and configuration changes are covered in Section 3.0.

2.4 PROCEDURE

2.4.1 Pretest Procedure

T h e a r c h e a t e r w a s i n s t a l l e d on t h e t e s t s t a n d ; a l l a i r , w a t e r , a n d i n s t r u m e n t a t i o n c o n n n e c t i o n s w e r e c o m p l e t e d ; a n d t h e i n s t r u m e n t e d p r o b e s w e r e a l i g n e d t o t h e n o z z l e e x i t .

]0

Page 14: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75.127

T e s t v o l t a g e w a s t h e n a p p l i e d t o e n s u r e t h a t e x t e r n a l i n s u l a - t i o n w a s a d e q u a t e up t o 1 2 . 5 k v . T h e h e a t e r c h a m b e r w a s c o n n e c t e d t o a v a c u u m s y s t e m by a b r e a k a w a y s e a l a t t h e n o z z l e e x i t . T h e h e a t e r w a s c h e c k e d f o r g a s l e a k s w i t h t h e p r e s s u r e m a i n t a i n e d a t a l e v e l n e a r 1 mm Hg. T e s t . v o l t a g e was a g a i n a p p l i e d t o e n s u r e t h a t s t a r t i n g b r e a k d o w n v o l t a g e w i t h i n t h e h e a t e r w a s b e l o w 8 k v . C o o l i n g w a t e r w a s s u p p l i e d t o t h e h e a t e r a t t h e s c h e d u l e d o p e r a t i n g p r e s s u r e a n d f l o w r a t e , a n d a l e a k c h e c k o f a l l c o o l i n g c o m p o n e n t s was p e r f o r m e d . T h e w a t e r s y s t e m w a s t h e n s e c u r e d , a n d r o u t i n e i n s t r u m e n t a t i o n a n d a u x i l i a r y s y s t e m p r e o p e r a t i o n a l p r o c e d u r e s w e r e c o m p l e t e d . T h e v a c u u m was m a i n t a i n e d t h r o u g h o u t t h e p r e t e s t p r o c e d u r e s . T h e r e g u l a t e d a i r s u p p l y w a s p r e s e t f o r t h e p r e s s u r e r e q u i r e d f o r t h e r u n , a n d t h e e l e c t r i c a l l e a d s w e r e a t t a c h e d t o t h e h e a t e r . T h e h e a t e r was t h e n r e a d y f o r o p e r a t i o n .

2.4.2 Starting and Operating Procedure

The transformer tap position was set for the scheduled power level. The cooling-water systems were energized manually, proper flow rates established, and interlocks set. After checking the regulated air pressure and heater vacuum, the instrument recording systems were started. Electrical power to the heater was energized. When breakdown occurred and current was established, the air valve was opened automatically using the signal from a current-sensing device. Time required from arc initiation to full pressurization was about 1.5 sec. Nearly 8 to 10 sec were required for cooling water tempera- tures to stabilize for an energy balance. Models were injected as required during heater operation. For a normal shutdown, power termination automatically closed the air valve; then, cooling water and other support systems were manually secured. The heater conditions were preset for all runs and were not adjusted during any given run.

3.0 TEST DESCRIPTION AND RESULTS

3.1 RUN SUMMARY

Test summaries for the experimental effort are shown in Tables 1 and 2. Table 1 provides a summary of the test condi- tions and resulting heater performance and model data. Table 2 is a summary of test objectives, hardware configurations, and general remarks.

T h e h e a t e r w a s i n i t i a l l y o p e r a t e d on O c t o b e r 1 0 , 1 9 7 4 . T h e h a r d w a r e c o n f i g u r a t i o n was d e s c r i b e d i n S e c t i o n 2 . 3 a n d i s s h o w n i n F i g . 3 . A s h a k e d o w n r u n (Run 1 ) was m a d e a t 5 0 . 5 a t m

II

Page 15: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

chamber pressure, and energy balance runs (Runs 2 and 3) were made at 58.5 and 107 atm, respectively, to verify proper operation of the arc heater and to check the instrumentation by comparing the data with previous runs reported in Ref. 4.

Runs 4, 5, 6, and 7 were made at chamber pressures of 124, 130, 153, and 171 atm, respectively, in an effort to extend the operating pressure range of the segmented arc heater. Run 4 was a checkout run of 5.2 sec. Runs 5 and 6 were energy balance runs of 12 sec each and were so successful that disassembly of the heater was not required after either run. On Run 7 a channel segment failed at 2.8 sec, and the run was terminated at 3.1 sec. The chamber was fully pressur- ized after 1.7 sec, and at 2.0 sec a pressure pulse (lasting 0.05 sec) resulted in a momentary peak pressure of 186 arm in the heater. The inside walls of six channel segments partially collapsed from the pressure load. These segments were designed for a maximum gas pressure of 125 atm.

Runs 8 through ii were made with a standard tubular Linde-type anode assembly adapted to the segmented arc heater (see Fig. 5). The purpose of this modification was to deter- mine operational feasibility of a proven anode configuration and to evaluate heater performance. The effective arc length of the heater with this anode was about 24 in. This was accomplished by replacing all hardware upstream of the straight channel with the new anode assembly, body shell, air injector ring, and a body-to-segment transition piece. Runs 8 and 9 were shakedown runs with the new configuration. Run 8 resulted in an external insulation breakdown. Run 9 was a successful 5-sec run at 55 atm. An energy balance run (Run I0) was then made at 60 atm. The heater operation was normal for 6.6 sec, then the arc length shortened and the anode attachment relocated at the downstream end of the tube. Stable energy balance data points were recorded for both modes of operation and are presented in Table I, Runs i0-I and 10-2. No damage resulted from either mode of operation. Run II was an energy balance attempt at 102 atm; however, at 4.3 sec, three channel segments failed. No other damage occurred, and heater operation appeared normal prior to the segment failure.

At this point, the Linde-type anode configuration was replaced with the original ring anode (Fig. 3) in preparation for the evaluation of a new prototype segment design planned for the large segmented arc heater currently under design at AEDC. Runs 12 and 13 were check runs to ensure the heater was operating properly before the prototype segments were installed. Run 12 was inadvertently terminated at I.I sec. On Run 13, an energy balance was obtained at 107-arm chamber pressure with

]9 ,.

Page 16: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

. ~ f~

FLANGE

CATHODE ASSEMBLY-

DOWNSTREAM AIR

INJECTION

, FLOW

~ J ~I.IPSTREAM AIR INJECTION RING

-,CHANNEL SEGMENTS INSULATED

ASSEMBLY BOLTS

Figure 5. 5-MW segmented arc heater with Linde-type tubular anode assembly.

Page 17: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-T R-75-127

no p r o b l e m s e n c o u n t e r e d . The p u r p o s e o f Runs 14, 15, and 16 was t o e v a l u a t e t h e new p r o t o t y p e s e g m e n t d e s i g n ( s e e F i g . 6 ) . The m a j o r i m p r o v e m e n t s i n t h e p r o t o t y p e s e g m e n t s i n c l u d e d ( 1 ) r a d i a t i o n s h i e l d i n g o f t h e i n s u l a t o r s b e t w e e n s e g m e n t s , ( 2 ) t h i c k e r s e g m e n t w a l l s t o w i t h s t a n d h i g h e r g a s p r e s s u r e , and ( 3 ) p r o v i s i o n f o r a i r i n j e c t i o n b e t w e e n s e g m e n t s . T h r e e

L INS

"0

MYKROY INSU S /

FLOW

PR( SE

i

/

/

Figure 6. Prototype segment configuration.

new prototype segments were installed (Fig. 6) on Run 14. The heater was operated for 8 sec at 104-atm pressure. In general, the prototype segments were undamaged except for some minor erosion which occurred on one prototype segment, indicating some local arcing at the wall. An energy balance attempt on Run 15 resulted in a channel segment failure at 130 atm after 2.4 sec. Also, the wall of two of the prototype segments partially collapsed. Since defects had occurred

14

Page 18: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE D C - T R - 7 5 - 1 2 7

d u r i n g f a b r i c a t i o n , t h e t h r e e p r o t o t y p e s e g m e n t s w e r e r e p l a c e d w i t h t w o new p r o t o t y p e s e g m e n t s a n d a s t a n d a r d c h a n n e l s e g m e n t ~ A s u c c e s s f u l e n e r g y b a l a n c e w a s m a d e ( R u n 1 6 ) f o r 10 s e c a t 1 3 2 a r m . T h e p r o t o t y p e s e g m e n t s w e r e u n d a m a g e d , a n d t h e g e n e r a l c o n d i t i o n o f t h e h e a t e r a f t e r t h e r u n w a s g o o d .

T h e f i n a l r u n o f t h i s t e s t s e r i e s w a s a n e n d u r a n c e r u n a t 1 0 5 - a r m c h a m b e r p r e s s u r e . T h e p u r p o s e w a s t o v e r i f y t h a t l o n g e r r u n s w i t h t h e s e g m e n t e d a r c a t h i g h p r e s s u r e s a r e f e a s i b l e , t o d e t e r m i n e i f a d e g r a d a t i o n o f p e r f o r m a n c e o c c u r r e d w i t h t i m e , a n d t o v e r i f y t h a t p r e v i o u s r u n s o f 8 t o 1 2 s e c w e r e o f s u f f i c i e n t l e n g t h t o o b t a i n v a l i d e n e r g y b a l a n c e s f o r t h e s e g m e n t e d a r c . T h e h e a t e r r a n s u c c e s s f u l l y f o r 60 s e c , a n d t h e g e n e r a l c o n d i t i o n o f t h e h e a t e r w a s e x c e l l e n t a f t e r t h e r u n . M o d e r a t e e r o s i o n o f t h e a n o d e r i n g w a s e v i d e n t a f t e r t h e r u n .

3.2 ARC HEATER DATA

3,2.1HeaterPerformanceand Data Correlation Progrem

M e a s u r e d b u l k e n t h a l p i e s f o r t h e 5-MW s e g m e n t e d a r c h e a t e r a r e s h o w n i n F i g . 7 f o r v a r i o u s c h a m b e r p r e s s u r e s a n d e l e c t r ± c a l c u r r e n t s ° D a t a f r o m F Y 7 2 , 7 3 , a n d 74 a r e i n c l u d e d

8 0 0 0

7000

6000

.a 5 o o o

4000 .,-I ..s,- I,- Z tu 3000

- I ,. j m

20O0

IOOO

0 0

/ z / - /

o,

o , , , /

:op.=oN .Oj_E N FY72 Rtn8 /

FY73 Ring / ltl ~ FY74 Ring /

' \ , , ~%. . ~ .~e~ C ~ t . ~)1

• / * E n t h a l p y ]~mtimnted '?' • **Arc O ] r r e n t Est imated o) • _ _ m.85a 5

- . . o ~ . . _ . .

" • ."" ." .# ~ ~ ~ 6 (OO #////')',.~,~ ~ ~ ~ 0673 , ~ C o r r e l a t ton

" / / / / / ~ . . ~ ~ ~ ~ ~ ~ 6oo AMP

or~. ~x,-..r,. . . ~ . - ~ . ~ . ~ - - - - ~ A R C 0 P E R A T r O N

Note: Number near symbol ts a rc c u r r e n t l e v e l

| I I I I I I I I I I I I l I [ I | J

2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0

TOTAL PRESSURE, otm

Figure 7. 5-MW segmented arc heater performance data.

15

Page 19: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-TR-75-1 2"i

to provide a more complete data history of the heater. Also, since the heater was operated in a new test location with different instrumentation during FY75, it was desirable to verify that the performance data would repeat. Several FY75 data points near 60 atm and 105 atm show excellent repeat- ability with previous data. Measured performance ranged from about 5,700 Btu/lb at 60 atm to 3,500 Btu/ib at 153 atm. The Linde-type anode configuration did not show a significant improvement in enthalpy for the few runs attempted.

A data correlation program was formulated by Aerotherm Division, Acurex Corporation, under AF Contract F40600-74-C- 0015 (Ref. 7), based on previous energy balance data from the AEDC 5-MW segmented arc heater. This correlation was modified at AEDC to provide better agreement with the data and the following relationships were obtained:

c o r r

li C O T r

(i-.~ 0"75 rhO.4 0.16S volts = .t3o V57 Po

• I " 0 . 5 , I , 0 . 8 2 5

(1)

(2)

The sonic flow enthalpy equation (Winovich, Ref. 8) was used in conjunction with Eqs. (1) and (2):

--';~--- = 280 I l l °'397 ( 3 ) A * Po

w h e r e L = arc channel length, in.

D = channel bore diam, in.

= air mass flow rate, ib/sec

Po = total pressure, arm

I = arc current, amp

A* = sonic throat area, ft 2

H s = enthalpy based on sonic flow equation, Btu/ib

W i t h t h e c o r r e l a t i o n e q u a t i o n s , e n t h a l p y v a l u e s w e r e c a l c u l a t e d f o r c u r r e n t s o f 4 0 0 , 5 0 0 , a n d 600 amp u s i n g t h e g e o m e t r y o f t h e 5-MW s e g m e n t e d a r c h e a t e r . T h e s e v a l u e s a r e s u p e r i m p o s e d on t h e d a t a i n F i g . 7 . I n g e n e r a l , t h e a g r e e - m e n t i s g o o d b e t w e e n t h e m e a s u r e d a n d c a l c u l a t e d e n t h a l p i e s . F u r t h e r c o m p a r i s o n s o f e n t h a l p y , a r c v o l t a g e , a n d c h a m b e r p r e s s u r e a r e p r e s e n t e d i n F i g s . 8 a , b , a n d c , r e s p e c t i v e l y .

16

Page 20: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

- AE DC-TR-75-127

Agreement is excellent between measured and calculated values of voltage and pressure and generally good for enthalpy. More data scatter was expected in enthalpy because a minimum of 5 input parameters is required to perform an energy balance. Calculated enthalpies were consistently higher than measured values for the 26 atm pressure runs (FY72 Runs 4, 6, and 7) and for the Linde-type anode runs. This leads to the conclu- sion that efficiencies for these runs were lower than predicted, since the voltage levels were as predicted.

8 0 0 0

7000

tmJ

4ooo m Q

MJ

=E 2000

I000

I r~,4 I n*"g I • I I *"NI • I n~s I--*,del

On

I,:.

e X n t h a l p y E s t i m a t e d

0 4

O s IIS*B~.t

N o t e : Numbers Correspond t o Run Nos. i n T a b l e s 1 and 2

0 0 ICO0 2000 ~SO00 4000 5000 6000 7000

CALCULATED BULK ENTHALJ~, Blu/Ib (Correlat|on Equations)

To

80OO

a. Bulk enthalpy Figure 8. Comparison of measured and calculated values

of arc heater parameters.

17

Page 21: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-TR-75-127

600O

~ 4000

moo0

w 0 0

- I0-1 _ 9

" II 7 3

I I000 2000 3000 4000 5000 6000 7000

CALCULATED VOLTAGE, v (Correlat|on Equal:|ons)

b. Arc voltage

180

160

'4° f

i 8 0

60

40

20

. j • I " I ° I " I " * ° ' !

I ° I ' ~ I ~ * ' i ' ~

" I ° l ' ~ I ~ ° ' 1 / . I • I ~ 7 5 I L * "d ' I , . ' /

14 4

- ,~T~.i

~ : 5 I - 4 7 I 7~ 9 I I I I I I I I I I I I

20 40 6D 80 I00 120 140 160 BO CALCULATED TOTAL PRESSURE, alto

(Correlation Equatto.s)

c. Total pressure Figure 8. Concluded.

0 I

0

] 8

Page 22: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

A E D C - T R - 7 5 - 1 2 7

In o r d e r t o d e t e r m i n e i f t h e W i n o v i c h s o n i c f l o w e q u a t i o n ( R e f . 8) w e r e v a l i d f o r t h i s h e a t e r , a l o g a r i t h m i c p l o t o f m e a s u r e d v a l u e s o f ~ / A * p o v e r s u s H o was made ( s e e F i g . 9 ) . The d a t a s c a t t e r was r e l a t i v e l y s m ~ l l a n d a l i n e a r r e l a t i o n - s h i p e v i d e n t . The e x p r e s s i o n r e s u l t i n g f r o m a l e a s t s q u a r e s l i n e a r c u r v e f i t o f t h e d a t a was

- = 316 H j 0"414 ( 4 ) A* Po

This equation and the Winovich equation are superimposed on the data in Fig. 9. Either Eq. (S) or (4) can be used to calculate a reasonably accurate bulk enthalpy for this heater.

1.08

106

1.04

1.02

1.00

~ 0 . 9 8 Z .E

0.96

0 .94

0,92

0 . 9 0

r- . . . . . i / A t P o - 280 Hs -0"397 (Wlnev ich, R e f . 8)

p. \ ~ fk/A*Po - 316 Ho-0"414 (Least Squares L i n e a r ~ % C u r v e F i t o f I ~ t a )

I ° i " " I " * ~ 1 - " " I " I ' ~ " I ' i s ' l

~ f " I " " I ' inS I -- I

"~ i " i ~ 5 I ~ ' '~1 - * I • I FT?5 I ~Indel

- \

- - T

_ ,~ \ \

• E n t h a l p y Estimated

I1~ ~ D t \

I J' I 1 I I I I , I \1 I I 3.4 &5 ~6 37 38 39 40

LOG H o

Figure 9. Comparison of arc heater data with sonic flow equation.

3.2.2 Channel Segmen~ /

The c h a n n e l s e g m e n t d e s i g n s u s e d i n FY75 a r e shown i n F i g . 4 . The s e g m e n t w i t h t h e s i l v e r - s o l d e r c o n s t r u c t i o n ( F i g . 4 c ) was c o n s i d e r e d s u p e r i o r b e c a u s e t h e w a l l e x p o s e d t o g a s p r e s s u r e ( e x t e n d i n g p a s t t h e g a s s e a l ) was c o n t i n u o u s

19

Page 23: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-T R-75-127

a n d a n y w a t e r l e a k s w h i c h d i d o c c u r w e r e e x t e r n a l t o t h e a r c h e a t e r . H o w e v e r , t h e a d d i t i o n a l w i d t h o f u n s u p p o r t e d i n n e r w a l l m a d e t h e s e s e g m e n t s m o r e s u s c e p t i b l e t o w a l l d e f o r m a t i o n a t p r e s s u r e s g r e a t e r t h a n 1 0 0 a r m . A p h o t o g r a p h o f a n o r m a l a n d a p a r t i a l l y c o l l a p s e d w a l l i s s h o w n i n F i g . 1 0 . No s e g - m e n t p r o b l e m s w e r e e n c o u n t e r e d u n t i l t h e 1 7 1 - a t m r u n ( R u n 7 ) ,

CONFIGURATION: Silver-Soldered (Fig. 4c)

NORMAL WALL DEFORMED WALL

Figure 10. Channel segment wall cross section.

d u r i n g w h i c h s e v e r a l s i l v e r - s o l d e r e d s e g m e n t s d e v e l o p e d p a r t i a l l y c o l l a p s e d w a l l s . M o s t o f t h e s e g m e n t f a i l u r e s w h i c h o c c u r r e d o n l a t e r r u n s w e r e a t t r i b u t e d t o t h e p a r t i a l s e g m e n t d a m a g e w h i c h o c c u r r e d o n Run 7 . T h e w e l d e d s e g m e n t s F i g . 4 b ) w e r e n o t d e f o r m e d by t h e h i g h - p r e s s u r e g a s , b u t w a t e r l e a k s w h i c h d e v e l o p e d a t t h e w e l d j o i n t w e r e i n t e r n a l t o t h e h e a t e r . I n g e n e r a l , t h e s e s e g m e n t s w o u l d n o t w i t h - s t a n d t h e h i g h h e a t i n g r a t e s r e q u i r e d , a n d t h e r e f o r e , w e r e l o c a t e d n e a r t h e u p s t r e a m e n d o f t h e c h a n n e l . T h e o r i g i n a l EOS s e g m e n t s ( F i g . 4 a ) w e r e u s e d o n l y a s s p a r e s o r r e p l a c e - m e n t s f o r f a i l e d o r d a m a g e d s e g m e n t s w h i c h o c c u r r e d d u r i n g t e s t i n g . T h e s e s e g m e n t s w e r e v e r y s u s c e p t i b l e t o w a t e r l e a k a g e a t t h e s i l v e r - s o l d e r j o i n t .

A v e r a g e m e a s u r e d w a l l h e a t f l u x o f t h e c h a n n e l s e g m e n t s i s s h o w n i n F i g . 11 f o r a l l r u n s w h e r e d a t a w e r e a v a i l a b l e .

20

Page 24: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AE DC-T R-75-127

Measurements of rise in water temperature at eight segment locations along the channel were used to determine average fluxes. Heat fluxes ranged from below 3,000 Btu/ft2-sec at 50 arm to nearly 6,500 Btu/ft2-sec at 153 arm. Calculated heat fluxes based on the correlation program (Eqs. (I) and (2)) for arc currents of 400, 500, and 600 amp are also shown in Fig. ii. The agreement between calculated and measured heat fluxes was generally good.

9000 -

8000

u g

N. 7 0 0 0 - Ik -! m

- 6000 X

,,~ 500C

"I, 4OOO

I - Z ,,, 3000 X

" ' 2000

E

100Q' 0

I? I I? I I " I

FY75

Ring I Ring I Ring I

N o t e : Number n e a r s y m b o l d e n o t e s a r c c u r r e n t l e v e l

* A r c C u r r e n t E s t i m a t e d

rlsez

598

@sTa

- C o r r e l a t 1on F4uat tons

AMP

I I ! I ! I I I I I I I I I ! I I I I I 20 40 60 80 I00 120 140 160 180 200

TOTAL PRESSURE, otto

F i g u r e 1 1 . A v e r a g e c h a n n e l w a l l h e a t f l u x .

To properly design a channel segment configuration, a realistic knowledge of the voltage gradient that must be sustained at the channel wall is essential. Measured and calculated values of the voltage gradient encountered for the 5-.i~W segmented arc are shown in Fig. 12. The maximum mea- sured gradient was 372 v/in. at 171-arm chamber pressure. Correlation values were based on Eq. (I). The voltage gradi- ent was primarily a function of total pressure and only slightly affected by arc current.

21

Page 25: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

A E D C - T R - 7 5 - 1 2 7

5 0 0

4 0 0

I - z 3 0 0 bJ 3

0 2OO

W ¢,D

I 00

r r e l a t t ° n u a t i o n s

O0 AMP ~ 6 0 0 AMP

/

0 I I I I I I | I I I I I I I ! I I I I 0 2 0 4 0 6 0 8 0 I 0 0 120 140 160 180 2 0 0

T O T A L P R E S S U R E , etm

Figure 12. Measured and predicted voltage gradient.

3.2.3 Endurance Run

As s t a t e d i n S e c t i o n 3 . 1 , an e x t e n d e d r u n o f 60 s e c was made t o e v a l u a t e t h e f e a s i b i l i t y and t e m p o r a l s t a b i l i t y o f l o n g e r r u n s . F i g u r e 13 s h o w s a r e c o r d o f m e a s u r e d v a l u e s o f a r c v o l t a g e , c h a m b e r p r e s s u r e , and b u l k e n ~ h a l p y p l o t t e d e v e r y 10 s e c and a t s m a l l e r i n t e r v a l s d u r i n g t h e f i r s t 10 s e c o f o p e r a t i o n . V o l t a g e and c u r r e n t w e r e w i t h i n ±2 p e r c e n t o f t h e i r f i n a l v a l u e s a f t e r 2 s e c f r o m a r c i n i t i a t i o n , a n d e n t h a l p y a f t e r 8 s e c o f o p e r a t i o n . The h e a t e r o p e r a t i o n was e x t r e m e l y s t e a d y , a n d no v a r i a t i o n o c c u r r e d i n t h e l e v e l m e a s u r e d o f any p a r a m e t e r a f t e r 10 s e c o f o p e r a t i o n .

3.3 MODEL DATA

I m p a c t p r e s s u r e p r o f i l e s o f t h e n o z z l e e x i t f l o w a r e shown i n F i g . 14 f o r c h a m b e r p r e s s u r e s o f 107 , 132 , a n d 153 a tm . A p r e s s u r e p r o b e c o n t a i n i n g a h i g h r e s p o n s e t r a n s d u c e r was u s e d t o m e a s u r e t h e s e s t a g n a t i o n p o i n t p r e s s u r e s . The p r o f i l e s c o n t i n u e t o b e " f l a t " f o r c h a m b e r p r e s s u r e s a b o v e 100 a rm, s i m i l a r t o t h e p r o f i l e s f o r p r e s s u r e s b e l o w 100 a tm r e p o r t e d i n R e f . 4 .

T o t a l e n t h a l p y p r o f i l e s o f t h e e x i t f l o w a r e p r e s e n t e d i n F i g . 15 f o r t h e 1 5 3 - a t m o p e r a t i o n (Run 6 ) . The i n f e r r e d e n t h a l p y p r o f i l e was c a l c u l a t e d u t i l i z i n g t h e l a m i n a r F a y - R i d d e l l t h e o r y , t h e p r e s s u r e p r o f i l e d a t a ( F i g . 1 4 ) , a n d h e a t - t r a n s f e r m e a s u r e m e n t s made w i t h a n u l l - p o i n t c a l o r i m e t e r p r o b e . The m e a s u r e d e n t h a l p y p r o f i l e was o b t a i n e d f r o m

22

Page 26: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

A E D C - T R -7 5 -127

8 0 0 0

,, 6 0 0 0 z

~ , ~ - . J 0

u " 2 0 0 0 -

E 8 0 0 0 - 160

~ = 6 0 0 0 120 m

>.-

5 ~ 4 0 0 0 - 80

2000 40

0 - 0

o o

0 ~>

PO = 105 arm T e s t

H o = 3755 B t u l l b Run

T = 522 amp Date

Arc V01tage

• I • I • I • I , I ,

I0 20 30 40 50

5 ~ R 2 0 0 1

17 ~o 2-27-75

6O

Chamber Pressure

B u l k C n t h a l p y

t i t | t C a i = r i m e t e r Swept T h r e J g h F l o w a t T imes Shown by Arrow~

, , I m I , I , I , I m

0 I0 20 30 40 50 60 RUN TIME, mec

Figure 13. Endurance run.

G r r

U)

n , Q.

I -

8 0

6 0

40

20

4 N

! I I I i

Is , I Po, I nu"l I a t m I • o . I

: i , o , i 1~i I t ss I ZSl I '].s3 I 61

i~ech No, = 2 . 5 3

- 02 0 0.2 POSITION, In

0 -0.4 0.4

Figure 14. Impact pressure profiles at nozzle exit.

23

Page 27: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

A E D C - T R - 7 5 - 1 2 7

e n t h a l p y p r o b e d a t a ( R e f . 5 ) . The a v e r a g e c e n t e r l i n e i n f e r r e d e n t h a l p y was a b o u t 6 , 7 0 0 B t u / l b c o m p a r e d t o a m e a s u r e d e n t h a l p y o f 3 , 3 6 0 B t u / l b and a b u l k e n t h a l p y o f 3 , 5 0 0 B t u / l b . The i n f e r r e d e n t h a l p y d a t a may he i n f l u e n c e d by f r e e - s t r e a m t u r b u l e n c e e f f e c t s on t h e h e a t t r a n s f e r . W h i l e t h e s h a p e o f t h e p r o f i l e s i n F i g . 15 a r e n o t i d e n t i c a l , n e i t h e r show a n y e v i d e n c e o f c e n t e r l i n e " p e a k i n g . " The same c o n c l u s i o n was r e a c h e d f o r p r e s s u r e s b e l o w 100 arm ( s e e R e f . 4 ) .

SYH

O

A

H

DATA SO'dRC, E

I n fe r red Entha|py from Calorimeter and Pressure Orobes

E n t h a l w Probe

Measured Bulk £nthaipy

M = 2,53 Ho = 3492 B t u / l b

Po = 153 arm Run No. 6

p~ [] 51.99 arm Date: 11/14/74

I 0 0 0 0

J 6000

6000 J

4 0 0 0

J ~ 2000

O-0.4

I I I I

I I I I I -0.2 O 0.2

POSITION, ,n 0.4

Figure 15. Total enthalpy profiles at nozzle exit .

Heat-transfer profiles are shown in Fig. 16 f o r five consecutive sweeps of a null-point calorimeter during the 60-see endurance test (Run 17). Sweep direction and time of injection are shown in Fig. 13. Centerline values ranged from 9,600 Btu/ft2-sec for the first sweep to 10,800 Btu/ft 2- sec for the final sweep, representing a variation of ±6 percent. Again, centerline "peaking" was not observed on any of these traverses; however, high heat-transfer rates did occur near position 0.15 in., especially on sweep 5. The reason for the nonsymmetric profile was undetermined and was not typical on other runs.

24

Page 28: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

NULL-PO]NT CALORIHETER

M [] 2 .53 Ho = 3765 8 t u / l b m

Po = 105 atm Date: 2-27-75

p~ = 35.70 atm Run No. 17

16 ,000 I I I I I

I Tlme o f Sweep,[

- s e c I

u = 4.6

x 4 . 5 .-~, =1- 1 2 , 0 0 0 - 25.8 /

48.9 | . , , " ' ' - "

- See F|O. 13 --~'='=I~. ~.~":

z

B

/

UJ -r-

. J

. J =~ 4,000 ,-t

8

I 0 I I I I -0.4 -02 0 0.2 0.4

POSITION, in.

Figure 16. Nozzle exit heat-transfer profiles for the endurance run.

A E D C - T R - 7 5 - 1 2 7

3.4 C O M P A R I S O N OF P E R F O R M A N C E W I T H O T H E R A R C H E A T E R S

The p e r f o r m a n c e o f t h e AEDC 5-MW s e g m e n t e d h e a t e r i s c o m p a r e d w i t h o t h e r e x i s t i n g a r c h e a t e r s i n F i g . 7 . O p e r a t i o n o f t h e AEDC 5-MW s e g m e n t e d a r c b e t w e e n 30 and 150 a tm h a s p r o - d u c e d e n t h a l p i e s 6 0 - t o 7 0 - p e r c e n t h i g h e r t h a n t h e b e s t p e r f o r m a n c e g e n e r a l l y r e p o r t e d f o r o t h e r h i g h - p r e s s u r e a r c h e a t e r s . O t h e r e x i s t i n g s e g m e n t e d a r c h e a t e r s h a v e a l s o p r o d u c e d h i g h e n t h a l p i e s , b u t t h e y h a v e n o t b e e n o p e r a t e d a b o v e 3 0 - a r m p r e s s u r e and g e n e r a l l y o p e r a t e d b e l o w 15 a t m . T h u s , t h e AEDC 5-MW s e g m e n t e d a r c h e a t e r h a s a u n i q u e p e r f o r m - a n c e c a p a b i l i t y o f h i g h e n t h a l p y a t h i g h p r e s s u r e . I f m i n o r m o d i f i c a t i o n s a r e made t o a l l o w h i g h e r a r c c u r r e n t s , e v e n h i g h e r p e r f o r m a n c e c a n b e e x p e c t e d .

4.0 C O N C L U D I N G R E M A R K S

During the series of tests described in this report, the AEDC 5-MW segmented arc heater was operated at pressures up to five times higher than reported for other heaters of this

25

Page 29: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

type. No inherent difficulties were encountered which would prevent operation at pressures greater than 150 atm. Segment failures resulted almost entirely from wall deformation and not overheating. Average wall heat fluxes up to nearly 6,500 Btu/ft2-sec were measured without segment failure. Bulk enthalpy levels were up to 70-percent higher than reported for other existing high-pressure arc heaters. A correlation program was used which accurately predicts the heater perform- ance. Nozzle exit profiles of impact pressure and total enthalpy were basically flat with no centerline peaking. The effluent was observed to be clean and to have relatively steady intensity. Experience was gained in the operation of the segmented arc at pressures up to 171 atm, and several hardware configurations were evaluated and optimized. These data have been of great value during the design of the large segmented heater.

REFERENCES

1. R i c h t e r , R. " U l t r a h i g h P r e s s u r e Arc H e a t e r S t u d i e s , ( P h a s e I I I ) . " AEDC-TR-70-106 (AD866965) , March 1970 .

2. R i c h t e r , R. " U l t r a h i g h P r e s s u r e Arc H e a t e r S t u d i e s . " AEDC-TR-69-180 EOS R - 7 2 1 8 - F i n a l (AD859053) , S e p t e m b e r 1969 .

3. L e w i s , H. F . , Horn , D. D.', and P a t t o n , J . B . " R e s u l t s o f T e s t i n g U l t r a h i g h P r e s s u r e E l e c t r i c Arc H e a t e r s . " AEDC-TR-70-228 (AD875516) , O c t o b e r 1970 .

4. Horn , D. D. and Brown, S t . G . A . " R e s u l t s o f T e s t i n g t h e AEDC 5-MW S e g m e n t e d Arc H e a t e r . " AEDC-TR-74-108 (ADA002313) , D e c e m b e r 1974 .

5. S m i t h , R. T . , M a c D e r m o t t , W. N . , and G i l t i n a n , T. L. "A T r a n s i e n t E n t h a l p y P r o b e f o r t h e C a l i b r a t i o n o f H igh H e a t F l u x A b l a t i o n F a c i l i t i e s . " AEDC-TR-74-116 (ADA003950) , J a n u a r y 1975 .

6. H o r n , D . D . " A b l a t i o n T e s t i n g f o r T a s k s 3, 4, and 5 o f t h e R e - e n t r y S y s t e m s E n v i r o n m e n t a l P r o t e c t i o n (RESEP) P r o g r a m i n t h e AEDC 5 - M e g a w a t t Arc H e a t e r T e s t U n i t . " AEDC-TR-68-154 (AD837841) , A u g u s t 1968 .

7. N i c o l e t , W. E . , S h e p a r d , C. E . , e t a l . " A n a l y t i c a l and D e s i g n S t u d y f o r a H i g h - P r e s s u r e , H i g h - E n t h a l p y C o n s t r i c t e d Arc H e a t e r . " AEDC-TR-75-47 (ADA012551) , J u l y 1975 .

8. W i n o v i c h , W. "On t h e E q u i l i b r i u m S o n i c - F l o w Method f o r E v a l u a t i n g E l e c t r i c - A r c A i r - H e a t e r P e r f o r m a n c e . " NASA TN D-2132 , March 1964 .

26

Page 30: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

-.4

Throat Diam - 0.215 ~n.

Table 1. 5-MW Segmented Arc Data Summary

Test 5MWR20Ol Arc Heater Data

Run Po' t . V. ,t . Ho ' 11. Run Date Time, atm amp vo l ts lb/sec Btu/ lb

se¢

I 10-10-74 4.1 5().b 556 3140 0.126

2 IO-23-74 16 1 511 5 533 3420 0.138 4634 36.3

I 10-25-74 15.1 107 551 5050 0.266 4101 40 3

4 11-06-74 5.2 124 573 5620 0.325 3934* 40.8*

5 11-12-74 12.0 130 560 5670 0 34~ 3612 40.7

6 11-14-74 12.1 153 573 6320 0.424 3492 41.8 3,360

7 11-18-74 3 1 171 575 6700 0.460 3373* 41.2" Me

12-16-14 5.1 III|D I ANODE M(DIFII:AII ~I, TIE-B(LT INSULIIOR 8REA DO,IN: EX~ i

0 12-20-741 5.0 55.2 his 4140 0.128 5706* 35.6* Me(

10-1 12-30-74:15.0 59.0 bqo 4280 0.11~ 5591 30.9 NA

10-2 60.5 598 4080 0.135 5690 32 5

11 1-03-75 4.6 102.O 555 6480 0.262 4477* 33.7*

12 1-15-75! 1.1 84.1 591 4256 0.259 -

13 1-23-75 7.9 101 551 5050 0.279 4005 41.3

14 ?-10-75 8.0 104 550* 5090 0.264 4357* 42.4*

15 ?-14-75 2.8 130 5770 0.343

16 2-21-75 10.0 132 b/8 5800 0.34~ 3814 40.6

17 2-27-75 60,1 105 522 5120 0 278 3765 40.2

*Estimated NA - Not ava i lab le .

FY75

Model Data on Centerl lne of Flow

L I I t h d l p y N u l l - P o i n t I m p a c t ' ~ e s s u r o Probe ~ n l o r i t ~L l~ r Probe"

• Hp iC w Hln f po

Me el Injectio~ Syst( qA

rlo el In jec l lon Syst( NA

Mo el Injecl~on Syste NA

- 42.B

11o400 b,200 43.0

13,600 6,700 53.0

els Not t lected.

ERNAL ARI

els Not ~jected

11,600 9,000 20.4

Mo(els Not 1jected.

ORIGINAl ANODE C(,NFISURAIJ IN

NA g,o00 5,3011 35.5

Motels Not njected

Mo(els Not njected.

NA 9,5(10 5.100 44 8

NA 10,200 6,000

Remarks

Arc attachment on both electrodes upstream of optimum

Arc attachment optlmlzed at both anode and cathode

Arc attachment upstream of optlmum On both electrodes

Three models Injected; recorder on low speed

Enthalpy probe damaged prior tO run

Arc attach~unt nearly optimum n. both electrodes

Cha~neI segment failed at 2.8 sec

Arc attachment nornB1 On both electrodes.

Non,dl arc length Short arc; arc attachment on anode at down- stream end; segment fa i l ed at end of run.

Three channel segments destroyed.

Heatp~.¢ut .of f before condit ions s tan l l l zeo

No problem encountered. Three 2D-MW prototype seyments

ins ta l led .

Channel segment f a i l ed .

Two 2n-MW prototype segments survlved unaamaeo.

Moderate anode erosion•

~> m

¢3

-n

ol L, .. j

Page 31: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

Table 2. Descriptive Test Summary for FY75

TEST 5HWR2001

~> r n

-n

01 . a P~

Run

.

Objective Configuration Remarks

Short shakedown Pun at 50 atm, 550 amp

Energy balance run at 55 arm, 525 amp

I n i t i a l conf igurat ion shown in Fig. 3, except four upstream segments were ins ta l led . Ten welded segments and 37 s i l v e r - soldered segments (of which 21 were new) were ins ta l led in the channel. The O.067-in.- diam o r t f i ce was ins ta l led tn the a i r l ine to the end plate; the O.O18-in.-dtam o r i f i c e was in the a i r l i ne to the down- stream a i r in jec t ion r ing. A new tubular cathode assembly and a modified end plate allowed tnspectiQn of the heater at each end.

Same as Run 1, except O.078S- in.-dJam o r i f i c e Ins ta l led in a t r l i ne to end plate and O.028-in.-dtam o r i f i c e i n s t a l - led in the a i r l i ne to down- stream a i r in jec t ion r ing.

The run was good and no damage occurred to any components. The heater was inspected from both ends a f te r the run without removing i t from the stand. The arc attachment locat ion on both - electrodes was upstream of optimum, ind icat ing a need for re- d i s t r i bu t i on of the a i r supply.

Run was excel lent and arc attach- ment locations were nearly optimized at both the anode and cathode.

Page 32: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

RUN

3

4

5

6

Table 2. Continued

Objective Configuration Remarks

Energy balance run at Same as Run 2, except the O.089-in.-diam or i f ice installed in a i r l ine to the end plate.

100 atm, 540 amp

Short run at 125 atm, 550 amp

Energy balance run at 125 arm, 550 amp

Energy balance run at 150 arm, 550 amp

Same as Runs 2 and 3, except the O.1015-in.-diam or i f ice installed in air l ine to the end plate. Changed anode l iner (used).

Same as Run 4, except the O.037-in.-diam or i f ice instal- led in the a i r l ine to the downstream air injection ring. Installed Mykroy insulator adjacent to upstream ai r ring.

Same as Runs 4 and 5, except the O.0465-in.-diam or i f ice installed in the a i r l ine to downstream ai r injection ring.

Run was good and no damage was encountered. Arc attachment s l ight ly upstream of optimum on both anode and cathode. Two welded segments had "hot spots" on them after the run; X-rays revealed partial blockage of water passage on both segments. Anode l iner was severely eroded and ready for replacement (this l iner was used continuously since Run 18 in FY72 with an accumulated time of 200 sec)

Check run was good. Arc attachment was s l ight ly downstream of optimum on anode and s l ight ly upstream of optimum on the cathode. Boron ni tr ide insulator adjacent to up- stream ai r injection ring eroded severely by the cold a i r swirl.

Heater was in good condition after the run. Arc attachment optimized on anode, s l ight ly upstream of optimum on the cathode. Mykroy insulator adjacent to upstream ai r ring was not eroded by a i r swirl.

No problems were encountered during the run, and post inspection showed the heater to be in excellent condition, Arc attachment was nearly optimum on both electrodes.

)> m C2

~0

-m

,,4

Page 33: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

Table 2. Continued

3> I l l '

0 (3

3O

U1

t ~

b~

Run

7

Objective

Energy balance run at 16S atm, 560 amp

Shakedown run with Linde-type anode at 55 atm, 530 amp

Same as Run 8

Configuration 11 - -

Same as Run 6

Llnde-type anode and adaptor pieces installed upstream of channel segments as shown in Fig. 5. The O.037-in.-dlam or i f ice installed in the a i r l ine to the downstream air injection ring.

Same as Run 8; external insulatlon on t ie bolts and cathode water manlfold improved.

Remarks

I A channel segment burned through l after 2.8-sec run time. The heater I was fu l ly pressurized; however, I some fluctuations in voltage and i chamber pressure were observed prior ! to the segment fai lure. Peak chamber I pulse was 186 arm. The pressure I wall was deformed on the inside

surface of six silver-soldered channel I i segments, probably caused by the high l gas pressure and wide segment wall.

The electrodes and other areas of • the heater were undamaged. I

I I

Vacuum s ta r t was normal, however, external arc occurred as airflow was in i t iated, Power was terminated S.] sac after arc in i t ia t ion . Damage was minor and was confined primarily to external tubes and insulators. External arc caused by insuff ic ient insulation on t ie bolts.

Check run was good; the chamber pres- sure and voltage were free of fluctuations. Arc attachment locations optimum on both electrodes.

Page 34: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

Run

10

11

12

Table 2. Continued

Objective

Energy balance run at 60 atm, 550 amp

Energy balance run at 100 atm, 550 amp

Energy balance run at 105 atm, 550 amp

Configuration i

Same as Run 9

Same as Runs g and 10

Linde-type anode was replaced with the original ring-type electrode. Configuration same as Run 5, except the 0.089-in.- diam or i f i ce was instal led in the a i r l ine to the end plate.

Remarks

The heater run was normal for 6.6 sec, then the arc length shortened to near the downstream end of the anode tube. Attachment also occurred on the channel t ransi t ion piece upstream of the channel. No damage occurred and the heater performance was not altered signi- f icant ly (compare data sum~ry points 10-1 and 10-2). Channel segment fatled 0.1 sec pr ior to normal shut- down, but did not affect the run.

The heater run was normal for 3.6 sec, then arc attachment apparently occurred along channel wall at 15 to 20 segment positions in the downstream half of the channel. Three segments fai led at 4.3 sec, which resulted in heater cutoff at 4.6 sec. Arc attachment at the anode looked normal af ter the run. Damage was confined to the three segments that fatled and some minor external hose and insulator damage.

Vacuum check indicated small water leak prior to run; therefore, pressure in the heater was above normal. After open circuit voltage was applied momentarily, the heater start was normal. After l.l sec the run was inadvertently terminated. No damage occurred to the heater. The water leak was from a s i lver-solder joint in a tapered seg- ment. About 80 percent of the intended chamber pressure was reached before the run was terminated.

3> rn o t-) : t Zl (.In

, , j

Page 35: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

I J

Run

13

14

15

16

Table 2. Continued

Objective

Same as Run 12

Energy balance run at 105 arm, 550 amp to evaluate three 20-MW prototype segments

Energy balance run at 130 atm, 560 amp

Same as Run IS

i

Configuratlon

Same as Run 12

Same as Runs 12 and 13 except three 20-MW prototype segments were installed (one straight and two tapered segments were installed at the downstream end of the channel).

Same as Run 14, except the 0.101S-ln.-diam orifice was installed in the air line to the end plate and the 0.0465- in.-diam orif ice was installed in the line to the downstream air ring.

Same as Run 15, except the three original 20-MW prototype segments were removed. Two replacement prototype segments were installed at the tapered locations.

Remarks

Run was good and no damage occurred to any heater components. Arc attachment was slightly upstream of optimum on the anode ring. Cathode attachment was normal.

General condition of the heater was good after the run. Arc attachment was normal on both electrodes. Minor erosion occurred on one 20-MW prototype segment indicating possible arc attachment, but in general the three prototype segments were undamaged.

Vacuum check revealed water leak prior to run; the heater run was normal for 2.4 sec and chamber was ful ly pressurized, then a channel segment failed and terminated the run. The wall of two 20-MW proto- type segments collapsed and an internal water leak was found in the third one, which apparently caused the water leak before the run.

Run was good and no damage occurred to any heater components. Arc attachment nearly optimized on both electrodes. The two 20-MW prototype segments were not damaged.

m

C)

3O

lJ1

~J

Page 36: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

UJ UJ

Run

17

Obj ecti ve

60-sec endurance run at 100 atm, 520 amp

Table 2. Concluded

Confi guratt on

Same as Run 16, except the 0.037-tn.-diam or i f i ce Instal led in a i r ltne to the downstream ai r injection r|ng.

Remarks

Heater ran successfully for 60.1 sec without problems. Arc attach- ment was optimized on both electrodes; no evidence of any damage inside the heater, The anode surface was mderately eroded but had been Instal led since Run 12.

m I C~

at zl i

. , , j

Page 37: RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ...AEDC-TR-75-127 .~T~ [ JA[~ O v ,,,,r.RESULTS OF TESTING THE AEDC 5-MW SEGMENTED ARC HEATER AT PRESSURES UP TO 171 ATM PROPULSION WIND

AEDC-TR-75-127

D*

Hinf

H O

Hp

H S

I

M

Po

Po

qcw V

NOMENCLATURE

Nozzle throat diameter, in.

Total enthalpy inferred from heat-transfer rate, Btu/lbm

Total enthalpy from energy balance, Btu/ibm

Total enthalpy from enthalpy probe, Btu/lbm

Sonic flow enthalpy, Btu/ibm

Arc current, amp

Mach number

Air mass flow rate, ibm/sec

Total pressure, arm

Impact pressure, atm

Cold wall heat flux, Btu/ft2-sec

Arc voltage, v

Efficiency, percent

SUBSCRIPTS

corr Correlation value

34