retention sil

4
SKY Implantat System retention.sil retention.sil retention.sil retention.sil The comfortable prosthetic fixation

Upload: edy-bredent-medical-romania

Post on 21-Mar-2016

321 views

Category:

Documents


4 download

DESCRIPTION

Toothless old people often have big problems with their diet, because the prosthesis does not fi t properly, and they can not eat fresh solid food any longer. However, they stop at major surgery, so that they want simple yet effi cient solutions. TiSi.snap in combination with retention.sil is a fast and secure method to treat patients chairside with a comfortable fi xed prosthesis.

TRANSCRIPT

Page 1: Retention sil

SKY Implantat System

retention.silretention.silretention.silretention.sil

The comfortable prosthetic fi xation

Page 2: Retention sil

Tel. (+49) 0 73 09 / 8 72-4 40 | Fax (+49) 0 73 09 / 8 72-4 44 | www.bredent-medical.com | e-mail [email protected]. (+49) 0 73 09 / 8 72-4 40 | Fax (+49) 0 73 09 / 8 72-4 44 | www.bredent-medical.com | e-mail [email protected]

retention.sil

retention.sil retention.sil && TiSi.snap TiSi.snap TiSi.snap

Toothless old people often have big problems with their diet, because the prosthesis does not fi t properly, and they can not eat fresh solid food any longer. However, they stop at major surgery, so that they want simple yet effi cient solutions.

TiSi.snap in combination with retention.sil is a fast and secure method to treat patients chairside with a comfor-table fi xed prosthesis.

On the one hand, retention.sil is a silicon with very high tenacious strength, which is a resillent storage positi-on of the prosthesis resilliente perfect and the other is at TiSi.snap an abutment system with a defi ned retention and a good direction of insertion of the prosthesis. This combination provides the high level of patient comfort while eating and chewing and keeps the prosthesis stable in place.

Through the different angulations TiSi.snaps the residual bone can be optimally utilized so that complicated opera-tions are avoided.

With the different levels also, the space requirement in the prosthesis to the anatomic needs to be adjusted.

With this unique combination, the quality of life of many toothless elderly people are greatly improved at a reaso-nable cost.

retention.sil 400 retention.sil 600retention.sil 200 retention.sil 400retention.sil 400retention.sil 400retention.sil 400 retention.sil 600

40°40°40° 30°30°30°30°30°30°30° 22,5°22,5°22,5°22,5°22,5°22,5°22,5°22,5°22,5°22,5° 12,5°12,5°12,5°12,5°12,5° 5°5°5°5°5°5° -5°-5°-5°-5°-5°-5°

30°-40°30°-40°23°-12°

+5°- -5°

35° 17,5° 0°

The internal laboratory tests showed that the pull-off forces are very close to the median, and after 11,000 cycles (10 years) reduced only marginally.

With each of the three angulations 10 ° divergence can be com-With each of the three angulations 10 ° divergence can be com-With each of the three angulations 10 ° divergence can be com-pensated. The angulations, which are not covered, TiSi.snap can be pensated. The angulations, which are not covered, TiSi.snap can be individualized.individualized.

Pulling Pulling power

N8

7

6

5

4

3

2

1

beginninginvestigation

11.000cycles

NumberAmount of cyclescycles

retention.sil 600

retention.sil 400

retention.sil200

Page 3: Retention sil

retention.sil retention.sil && TiSi.snap TiSi.snap TiSi.snap

The fastest and most economical solution for den-The fastest and most economical solution for den-tures support.tures support.tures support.

With a thin running impression material, the positi-With a thin running impression material, the positi-With a thin running impression material, the positi-on of the abutment TiSi.snap is located.on of the abutment TiSi.snap is located.on of the abutment TiSi.snap is located.

After the cavity was conditioned with the multi-Liquid Sil, the retention.sil is fi lled up to the top.

The prosthesis is inserted with the still soft retenti-on.sil on TiSi.snap abutments. The patient closes his mouth and fi xes the prosthesis (3 minutes), under slight chew pressure.

After 3 min, the prosthesis is removed and the excess retention.sil is removed with the silicone cutters.

The retention.sil can be replaced, as needed or by The retention.sil can be replaced, as needed or by The retention.sil can be replaced, as needed or by the patients own wishes.the patients own wishes.It is available in three different retentive values in It is available in three different retentive values in It is available in three different retentive values in the set.the set.

The TiSi.snap abutment is not subject to wear and The TiSi.snap abutment is not subject to wear and The TiSi.snap abutment is not subject to wear and can be cleaned easily by the patient without dif-can be cleaned easily by the patient without dif-fi culty.fi culty.fi culty.

At the marked points the basel surface of the pros-thesis is ground out, chair side.

The adhesive force of the prosthesis on The adhesive force of the prosthesis on The adhesive force of the prosthesis on the TiSi.snap is set by selecting one of the TiSi.snap is set by selecting one of the TiSi.snap is set by selecting one of the three existing hardnesses of retenti-the three existing hardnesses of retenti-on.sil. Soft - medium - hard. The retenti-on.sil. Soft - medium - hard. The retenti-on.sil. Soft - medium - hard. The retenti-on.sil surrounds the TiSi.snap completly, on.sil surrounds the TiSi.snap completly, providing a high chewing comfort felt providing a high chewing comfort felt providing a high chewing comfort felt by a resilient bite due to the equally fl e-by a resilient bite due to the equally fl e-by a resilient bite due to the equally fl e-xible silicone.xible silicone.

The following pictures show how quik-The following pictures show how quik-The following pictures show how quik-kly and easily the prosthesis is fi xed on kly and easily the prosthesis is fi xed on kly and easily the prosthesis is fi xed on two implants at the chairside.two implants at the chairside.

First, the position of the TiSi.snap is lo-First, the position of the TiSi.snap is lo-First, the position of the TiSi.snap is lo-calized with the use of a soft impressi-on. Then these points are ground out of the prosthesis. After application of the primer the selected retention.sil hard-ness is applied into these cavities.After three minutes, the prosthesis is removed from the mouth and worked out silicone cutters.

The lucky patient leaves the practice after only a short aappointment with a comfortable, fi xed and implant sup-ported prosthesis, it can be remove by themselves and without to much practice.

Page 4: Retention sil

bredent medical GmbH bredent medical GmbH &&& Co.KG Co.KG& Co.KG&& Co.KG&Weissenhorner Str. 2 | 89250 Senden | GermanyWeissenhorner Str. 2 | 89250 Senden | GermanyWeissenhorner Str. 2 | 89250 Senden | GermanyTel. (+49) 0 73 09 / 8 72-4 40Tel. (+49) 0 73 09 / 8 72-4 40Tel. (+49) 0 73 09 / 8 72-4 40Fax (+49) 0 73 09 / 8 72-4 44Fax (+49) 0 73 09 / 8 72-4 44Fax (+49) 0 73 09 / 8 72-4 44www.bredent-medical.comwww.bredent-medical.comwww.bredent-medical.come-mail [email protected] [email protected] [email protected]

Mistake and subject to change reserved 03/13 000710GB 3Mistake and subject to change reserved 03/13 000710GB 3

Designation Shore hardness Pulling powers REF

retention.sil 200 25 SH 200 g / 2 Newton 580 RTS 25

retention.sil 400 50 SH 400 g / 4 Newton 580 RTS 50

retention.sil 600 65 SH 600 g / 6 Newton 580 RTS 65

REF 540 RT SET

Multisil-Primer 5 ml REF 520 0100 4

Special Silicon TrimmerØ 4,1 mmREF S00 1QG 41

The special silicone cutter is suitable for angled and lab handpiece.

retention.sil in 3 hardnessesretention.sil in 3 hardnessesretention.sil in 3 hardnessesretention.sil in 3 hardnessesMixing Tips and application Mixing Tips and application Mixing Tips and application instrumentinstrumentinstrument

1 mm1 mm

3,8 mm3,8 mm

REF TISI0Y31

TiSi.snap 3/1TiSi.snap 3/13 mm

REF TISI0Y53

TiSi.snap 5/3TiSi.snap 5/3

REF TISIAY17

TiSi.snap abutment 17,5°

REF TISIAY35

TiSi.snap abutment 35°

retention.sil retention.sil && TiSi.snap TiSi.snap TiSi.snap

Order information

1 mm

6 mm

REF TISI0Y51

TiSi.snap 5/1TiSi.snap 5/1

Available = calander week 18Available = calander week 18