revisions notes: rev description eco chk date 10 initial
TRANSCRIPT
ALL GROUND CABLES8 AWG (GRN)
22 AWG WHT (ALM)
22 AWG BLK (RTN)
22 AWG WHT (NC)
22 AWG BLK (COM)
ODC-100UNIVERSALALM CABLE
E5-1XXALARM CBLADAPTER
LINE POWERED(CUSTOMER INSTALLED)
ETHERNET OVERCOPPER DEVICE
(BACK VIEW)
TRUNK PRO PANEL(ETHERNET OVER COPPER CONFIG)
CUSTOMER INSTALLEDINPUT
AC TO DC RECTIFIER(BACK VIEW)
TEMP COMP
14 AWG RED (-48V)
10 AWG GRN (GND)10 AWG WHT (LINE 2)10 AWG BLK (LINE 1)
A FEED (E5-1XX #1)B FEED (E5-1XX #1)A FEED (E5-1XX #2)B FEED (E5-1XX #2)POWER (HEAT EX.)
SURGEPROTECTOR
MECHANICALGEN-CON
INTERLOCK
BO
ND
ING
ST
RA
PIN
STA
LL IF
PRIM
AR
Y D
ISC
ON
NEC
T(C
UST
OM
ER IN
STA
LLED
)
INSTALL IF120VAC INSTALL
(CUSTOMER INSTALLED)
120 VACCONVENIENCEOUTLET (GFI)
GENERATORCONNECTOR
(OPTIONAL)
L1 L2 N G
X Y Z GRN
RECTIFIERSHELF FEED
TO BATTERY WARMER(OPTIONAL)
CUSTOMERSUPPLIED
INPUT120/240 VAC
50-60HzSINGLE PHASE
L1 L2 G
10-8 AWG(CUSTOMER SUPPLIED)
NL1G
NEUTRAL
L1
L2
L1 L2 N G
GROUND
L1 L2 NG
RECTIFIERCONVENIENCEN/AGEN CONBONDINGAC GROUND INN/ACABINET
CU
STO
MER
GEN
CO
N
SUR
GE
OU
TLE
TB
ATT
HT
R
REC
TIF
IER
PRIM
AR
YD
/C
30 AMPGEN CON
30 AMPMAIN
30 AMPRECTIFIER
15 AMPOUTLET
15 AMPBATT HT
(BLK)
10 AWG (BLK)14 AWG (BLK)
10 AWG (RED)
10 AWG (GRN)
(RED)
10 A
WG
(G
RN
)
10 A
WG
(W
HT
)
10 A
WG
(B
LK)
14 A
WG
(B
LK)
14 A
WG
(W
HT
)
14 A
WG
(G
RN
)
14 A
WG
(B
LK)
14 AWG (BLK)
14 AWG (WHT)
(WHT)
10 AWG (WHT)
14 AWG (WHT)
(GRN)
8 A
WG
(G
RN
)
10 A
WG
(W
HT
)
14 A
WG
(G
RN
)
SURGE
BATTERY WARMER (OPTIONAL)
AC LOAD CENTER
BATTERIES
14 AWG BLK (-48V RTN)
22 AWG BLK (-48V RTN)
22 AWG RED (-48V)
10 AW
G R
ED (-48V
)
10 AW
G B
LK (-48V
RT
N)
TEMP COMP22 AWG BLK/WHT
-48V(RED)
-48V RTN(BLACK)
RED (-48V)
TEM
P CO
MP
BLACK (-48V RTN)
+
+I
I
E5-1XX
CO
NSO
LE
PWR
SYS
ALM
ALA
RM
SFP 1SFP 2
E5-1XX #1(FRONT VIEW)
+
+I
I
E5-1XX
CO
NSO
LE
PWR
SYS
ALM
ALA
RM
SFP 1SFP 2
E5-1XX #2(FRONT VIEW)
PRO PANEL 2
PRO PANEL 1
CABINET MAINGROUND
SUB PRO PANEL 2
SUB PRO PANEL 1
TRUNK PRO PANEL
REMOTE PRO PANEL
AC LOAD CENTER
EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT
CUSTOMERINSTALLED
(EARTH GROUND)
HEAT EXCHANGERPOWER & ALARMS
(1) BLK (-48V RTN)
(2) RED (-48V)
(3) WHT (ALM)
(4) BLK (RTN)
SUBSCRIBER PROTECTOR PANEL(FRONT VIEW)
PIN # DESCRIPTION
3 RECTIFIER ALARM
RECTIFIER ALARM RETURN
HEAT EX. ALARM RETURN
HEAT EX. ALARM
DOOR ALARM NC
DOOR ALARM COM
7
4
8
5
9
E5-1XX ALARM INPUT
(ODC-100 LOCAL POWER WIRING DIAGRAM)E5-1XX CONFIGURATION
X
X
X
X
X
X
X
X
134 2
DOORSWITCH(FRONT)
NC
C
DOORSWITCH(SIDE)
NC
C
22AWG(WHT)
22AWG(BLK)
22AWG(WHT)
22AWG(BLK)
Notes:
The information contained in this document is theproprietary and confidential information of Calix. Youwill not provide, make available or disclose (or usefor any purpose other than that contemplated bythis document) any such information to any otherparty without the express, written consent of Calix.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
A A
B B
C C
D D
E E
1/8/08- TETINITIAL RELEASE103/20/08- TETUPDATED PRO PANEL GNDS AND ACLC114/15/11- TETADDED E7 AND B SERIES COMPONENTS12
REV DESCRIPTION ECO CHK DATEREVISIONS
.X = .5
.XXX = .100
.XX = .25
X = 3
31N/A
--
1/8/08T. TAYLOR
1/8/08T. TAYLOR
12390-00167
Wiring Diagram, ODC-100, Local PowerALL DIMENSIONS ARE IN INCHES
ANGLES = +/- 2DegFRACTIONS = +/- 1/32"
TOLERANCES: UNLESS OTHERWISE SPECIFIED
PROJECTION3RD ANGLE
FINISH:
MATERIAL:
MFG
ENGR
DRN BY
DATEAPPROVALS
DO NOT SCALE DRAWING SHEET OFSCALE
REVDWG NO.
(707) 766-3000PETALUMA, CA 94954
1035 N. McDOWELL BLVD
ALL GROUND CABLES8 AWG (GRN)
22 AWG WHT (ALM)
22 AWG BLK (RTN)
22 AWG WHT (NC)
22 AWG BLK (COM)
ODC-100UNIVERSALALM CABLE
E7-2ALARM CBLADAPTER
LINE POWERED(CUSTOMER INSTALLED)
18 AWG RED (-48V)18 AWG BLK (-48V RTN)
ETHERNET OVERCOPPER DEVICE
(BACK VIEW)
TRUNK PRO PANEL(ETHERNET OVER COPPER CONFIG)
CUSTOMER INSTALLEDINPUT
AC TO DC RECTIFIER(BACK VIEW)
TEMP COMP
10 AWG GRN (GND)10 AWG WHT (LINE 2)10 AWG BLK (LINE 1)
A FEED (E7-2 #1)B FEED (E7-2 #1)A FEED (E7-2 #2)B FEED (E7-2 #2)A FEED (E7-2 #3)B FEED (E7-2 #3)
POWER (HEAT EX.)
SURGEPROTECTOR
MECHANICALGEN-CON
INTERLOCK
BO
ND
ING
ST
RA
PIN
STA
LL IF
PRIM
AR
Y D
ISC
ON
NEC
T(C
UST
OM
ER IN
STA
LLED
)
INSTALL IF120VAC INSTALL
(CUSTOMER INSTALLED)
120 VACCONVENIENCEOUTLET (GFI)
GENERATORCONNECTOR
(OPTIONAL)
L1 L2 N G
X Y Z GRN
RECTIFIERSHELF FEED
TO BATTERY WARMER(OPTIONAL)
CUSTOMERSUPPLIED
INPUT120/240 VAC
50-60HzSINGLE PHASE
L1 L2 G
10-8 AWG(CUSTOMER SUPPLIED)
NL1G
NEUTRAL
L1
L2
L1 L2 N G
GROUND
L1 L2 NG
RECTIFIERCONVENIENCEN/AGEN CONBONDINGAC GROUND INN/ACABINET
CU
STO
MER
GEN
CO
N
SUR
GE
OU
TLE
TB
ATT
HT
R
REC
TIF
IER
PRIM
AR
YD
/C
30 AMPGEN CON
30 AMPMAIN
30 AMPRECTIFIER
15 AMPOUTLET
15 AMPBATT HT
(BLK)
10 AWG (BLK)14 AWG (BLK)
10 AWG (RED)
10 AWG (GRN)
(RED)
10 A
WG
(G
RN
)
10 A
WG
(W
HT
)
10 A
WG
(B
LK)
14 A
WG
(B
LK)
14 A
WG
(W
HT
)
14 A
WG
(G
RN
)
14 A
WG
(B
LK)
14 AWG (BLK)
14 AWG (WHT)
(WHT)
10 AWG (WHT)
14 AWG (WHT)
(GRN)
8 A
WG
(G
RN
)
10 A
WG
(W
HT
)
14 A
WG
(G
RN
)
SURGE
BATTERY WARMER (OPTIONAL)
AC LOAD CENTER
BATTERIES
22 AWG BLK (-48V RTN)
22 AWG RED (-48V)
10 AW
G R
ED (-48V
)
10 AW
G B
LK (-48V
RT
N)
TEMP COMP22 AWG BLK/WHT
-48V(RED)
-48V RTN(BLACK)
RED (-48V)
TEM
P CO
MP
BLACK (-48V RTN)
BATTERY WARMER (OPTIONAL)
OPTIONAL 2ND STRING BATTERY KIT
KIT CONTENTS:- 2ND STRING BATTERY HARNESS- ADD ON BATTERY BASE- BREAKERS FOR BOTH STRINGS- NEW VALERE BREAKER
PIN # DESCRIPTION
PRO PANEL 2
PRO PANEL 1
CABINET MAINGROUND
SUB PRO PANEL 2
SUB PRO PANEL 1
TRUNK PRO PANEL
REMOTE PRO PANEL
AC LOAD CENTER
EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT
CUSTOMERINSTALLED
(EARTH GROUND)
HEAT EXCHANGERPOWER & ALARMS
(1) BLK (-48V RTN)
(2) RED (-48V)
(3) WHT (ALM)
(4) BLK (RTN)
SUBSCRIBER PROTECTOR PANEL(FRONT VIEW)
OPTIONAL 100 PAIRPROTECTOR PANEL
AL1+ RECTIFIER MAJOR ALARM
RECTIFIER MAJOR ALARM RET
RECTIFIER MINOR ALARM
RECTIFIER MINOR ALARM RET
AC FAIL
AC FAIL RET
AL1-
AL2+
AL2-
AL3+
AL3-
REMOTE POWER MAJOR ALARMAL4+
REMOTE POWER MAJOR ALARM RETAL4-
HEAT EX. ALARMAL5+
HEAT EX. ALARM RETAL5-
REMOTE POWER FAN ALARMAL6+
REMOTE POWER FAN ALARM RETAL6-
DOOR ALARMAL7+
DOOR ALARM RETAL7-
E7-2 ALARM INPUT
(ODC-100 LOCAL POWER WIRING DIAGRAM)E7-2 CONFIGURATION
X
X
X
X
X
X
X
X
X
X
X
X
134 2
DOORSWITCH(FRONT)
NC
C
DOORSWITCH(SIDE)
NC
C
22AWG(WHT)
22AWG(BLK)
22AWG(WHT)
22AWG(BLK)
E7-2 #1(BACK VIEW)
E7-2 #2(BACK VIEW)
E7-2 #3(BACK VIEW)
Wiring Diagram, ODC-100, Local Power390-00167 REV 12, SHEET 2 OF 3
ALL GROUND CABLES8 AWG (GRN)
22 AWG WHT (ALM)
22 AWG BLK (RTN)
22 AWG WHT (NC)
22 AWG BLK (COM)
ODC-100UNIVERSALALM CABLE
B6-0XXALARM CBLADAPTER
LINE POWERED(CUSTOMER INSTALLED)
18 AWG RED (-48V)18 AWG BLK (-48V RTN)
ETHERNET OVERCOPPER DEVICE
(BACK VIEW)
TRUNK PRO PANEL(ETHERNET OVER COPPER CONFIG)
CUSTOMER INSTALLEDINPUT
AC TO DC RECTIFIER(BACK VIEW)
TEMP COMP
10 AWG GRN (GND)10 AWG WHT (LINE 2)10 AWG BLK (LINE 1)
A FEED (B6 #1)B FEED (B6 #1)A FEED (B6 #2)B FEED (B6 #2)A FEED (B6 #3)B FEED (B6 #3)
POWER (HEAT EX.)
SURGEPROTECTOR
MECHANICALGEN-CON
INTERLOCK
BO
ND
ING
ST
RA
PIN
STA
LL IF
PRIM
AR
Y D
ISC
ON
NEC
T(C
UST
OM
ER IN
STA
LLED
)
INSTALL IF120VAC INSTALL
(CUSTOMER INSTALLED)
120 VACCONVENIENCEOUTLET (GFI)
GENERATORCONNECTOR
(OPTIONAL)
L1 L2 N G
X Y Z GRN
RECTIFIERSHELF FEED
TO BATTERY WARMER(OPTIONAL)
CUSTOMERSUPPLIED
INPUT120/240 VAC
50-60HzSINGLE PHASE
L1 L2 G
10-8 AWG(CUSTOMER SUPPLIED)
NL1G
NEUTRAL
L1
L2
L1 L2 N G
GROUND
L1 L2 NG
RECTIFIERCONVENIENCEN/AGEN CONBONDINGAC GROUND INN/ACABINET
CU
STO
MER
GEN
CO
N
SUR
GE
OU
TLE
TB
ATT
HT
R
REC
TIF
IER
PRIM
AR
YD
/C
30 AMPGEN CON
30 AMPMAIN
30 AMPRECTIFIER
15 AMPOUTLET
15 AMPBATT HT
(BLK)
10 AWG (BLK)14 AWG (BLK)
10 AWG (RED)
10 AWG (GRN)
(RED)
10 A
WG
(G
RN
)
10 A
WG
(W
HT
)
10 A
WG
(B
LK)
14 A
WG
(B
LK)
14 A
WG
(W
HT
)
14 A
WG
(G
RN
)
14 A
WG
(B
LK)
14 AWG (BLK)
14 AWG (WHT)
(WHT)
10 AWG (WHT)
14 AWG (WHT)
(GRN)
8 A
WG
(G
RN
)
10 A
WG
(W
HT
)
14 A
WG
(G
RN
)
SURGE
AC LOAD CENTER
22 AWG BLK (-48V RTN)
22 AWG RED (-48V)
10 AW
G R
ED (-48V
)
10 AW
G B
LK (-48V
RT
N)
TEMP COMP22 AWG BLK/WHT
-48V(RED)
-48V RTN(BLACK)
BATTERY WARMER (OPTIONAL)
BATTERIES
RED (-48V)
TEM
P CO
MP
BLACK (-48V RTN)
BATTERY WARMER (OPTIONAL)
OPTIONAL 2ND STRING BATTERY KIT
KIT CONTENTS:- 2ND STRING BATTERY HARNESS- ADD ON BATTERY BASE- BREAKERS FOR BOTH STRINGS- NEW VALERE BREAKER
PRO PANEL 2
PRO PANEL 1
CABINET MAINGROUND
SUB PRO PANEL 2
SUB PRO PANEL 1
TRUNK PRO PANEL
REMOTE PRO PANEL
AC LOAD CENTER
EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT
CUSTOMERINSTALLED
(EARTH GROUND)
HEAT EXCHANGERPOWER & ALARMS
(1) BLK (-48V RTN)
(2) RED (-48V)
(3) WHT (ALM)
(4) BLK (RTN)
SUBSCRIBER PROTECTOR PANEL(FRONT VIEW)
PIN # SHELF DESCRIPTION
5 B6 #1 RECTIFIER ALARM
HEAT EX. / DOOR ALARMB6 #25
B6-0XX ALARM INPUT
(ODC-100 LOCAL POWER WIRING DIAGRAM)B6-0XX CONFIGURATION
X
X
X
X
X
X
X
X
134 2
DOORSWITCH(FRONT)
NC
C
DOORSWITCH(SIDE)
NC
C
22AWG(WHT)
22AWG(BLK)
22AWG(WHT)
22AWG(BLK)
B6 #1(BACK VIEW)
B6 #2(BACK VIEW)
B6 #3(BACK VIEW)
Wiring Diagram, ODC-100, Local Power390-00167 REV 12, SHEET 3 OF 3