rf solution rev1 20120321

19
No RF Solution Solution1 Solution2 Solution3 Solution4 Solution5 Solution6 2G 2G 3G 2G 2G&3G 2G&3G Combiner 2G/3G Combiner 2G 2G&3G 2G&3G 2G&3G 2G&3G Combiner

Upload: yandamustika6205

Post on 26-Oct-2014

30 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: RF Solution Rev1 20120321

No RF Solution

Solution1

Solution2

Solution3

Solution4

Solution5

Solution6

2G 2G 3G

2G 2G&3G 2G&3G Combiner

2G/3G Combiner

2G2G&3G

2G&3G2G&3G 2G&3G Combiner

Page 2: RF Solution Rev1 20120321

Solution 8

Solution 9

Solution 10

Solution 11

Solution 12

Solution7

2G 2G 3G

2G 2G&3G

2G&3G

+2G&3G Combiner

2G&3G

2G&3G

+2G&3G Combiner

3G

Page 3: RF Solution Rev1 20120321

RF Antenna Type Combinner TypePer SectorRF Jumper

Length

N/A N/A 0

N/A 0

DX-1710-2170-65-18i-2F N/A <5M

CMA-B/6521/E0-6 or DX-1710-2170-65-18i-2F

DXX-1710-21701710-2170-6565-18i18i-MM N/A < 3 M

CMA-B/6521/E0-6

27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female

27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female

0 or 3M ( If Need

)

27030064 : Combiner, TYB-DBC1812-21, GSM1800/UMTS,Double Dual-Band Combiner,2 In 1(WCDMA DC by-pass),1710~1880MHz / 1920~2170MHz,7/16 DIN Female

Page 4: RF Solution Rev1 20120321

DX-1710-2170-65-18i-2F N/A 3 M

N/A

DXX-1710-21701710-2170-6565-18i18i-MM N/A

N/A

DXX-1710-21701710-2170-6565-18i18i-MMHBXX-6516DS-VTMCMA-BDHH_6521

MEGA Antenna :DX-1710-2170-65-19.5i-M

MEGA Combiner :Fingu Dual-Band Combiner 1920-2170MHZ 1710-1880MHZ

MEGA Antenna :DX-1710-2170-65-19.5i-M

MEGA Combiner :Fingu Dual-Band Combiner 1920-2170MHZ 1710-1880MHZ

MEGA Antenna :DX-1710-2170-65-19.5i-M

Page 5: RF Solution Rev1 20120321

Per Sector Per SectorScenarioRF Jumper Node B Jumper

Qty Length Qty

0 2 or 4 For IBC Site Existing Combiner port enough

0 2 or 4 For IBC Site Existing Combiner port not enough

2 or 4 3 M 2 For Macro

2 For Macro

3 M 2 For Macro

2 For Macro

< 5 M > 5 M RNP

Make Decision

< 5 M > 5 M RNP

Make Decision

Tower RC Enough, but 2G&3G antenna should install in the same height

0 or 2 ( If Need )

< 5 M > 5 M RNP

Make Decision

Tower RC Not Enough, No Space For Add New Feeder

2 or 4 (If we Have to Swap 2G Jumper)

Tower RC Not Enough, Have Space For Add New Feeder

< 5 M > 5 M RNP

Make Decision

No Space For Add New Feeder, Existing antenna already support 2G and 3G dual band

Page 6: RF Solution Rev1 20120321

2 3 M 2 For Macro

For Macro

For Macro New Site/Additional Sector 2G&3G

For Macro New Site/Additional Sector 2G&3G

For Macro

For Macro Additional Sector 3G (no 2G)

Tower RC Enough,and 2G&3G antenna can install in different height

Existing 2G Antenna has 4 port and supports dual band

New Site/Additional Sector 2G&3G (with RRU Solution)

Page 7: RF Solution Rev1 20120321

Solution Description

No Need Add Combiner

Add Combiner

Replace 2 G Antenna to 4 Port Antenna

Use existing 2 Port 3G Antenna + Combiner

Add 2 Port 3G Antenna + Special Mounting Pole, Move 2G Antenna to Special Mounting Pole

Replace 2 G Antenna to Dual Band Antenna + Combiner

Page 8: RF Solution Rev1 20120321

Using existing 4 port 2G&3G Antenna

Add 2 port 2G&3G Antenna + Combiner

Add 4 port 2G&3G Antenna

Add 2 port 2G&3G Antenna + Combiner

Add 2 port 3G Antenna

Add 2 Port 3G Antenna + Normal Mounting Pole, No need to touch 2G Antenna

Page 9: RF Solution Rev1 20120321

RNP Description

Add Antenna 3G 2-port, with adding mounting which have same level with existing 2G antenna è Antenna 3G proposed 2-port & No combiner proposed.

Replace with Antenna 2G/3G 2-port and combiner (without feeder) è Antenna 3G proposed 2-port, With combiner proposed & Antenna 3G proposed different with Antenna 2G existing.

Replace antenna 2G existing with antenna 2G/3G 4-port. è Antenna 3G proposed 4-port

Without replace anything, just add combiner è Antenna 3G proposed 2-port (same with 2G existing), With combiner proposed & Antenna 3G proposed same with Antenna 2G existing

Page 10: RF Solution Rev1 20120321

Add Feeder for 3G

Install Dual Band 2 port Antenna, Combiner, and Feeder

Install Dual Band 4 port Antenna and Feeder

Install RRU, Dual Band 2 port Antenna, and Combiner

Install 2 port 3G Antenna and Feeder

Add Antenna 3G 2-port, with normal mounting pole & No combiner proposed.

Page 11: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page11of20

SN Code Information Name Type Option Description PIC Data Provided / Document

1 1.1 Phase Project Basic Data Batch1;Batch2;Batch3;Batch4 Work Package or Standalone PO PC

2 1.2 Zone Project Basic Data Zone1 (Java); Zone2 (Sumatra); Zone3 (KalSul) Zone Information PC

3 1.3 Region Project Basic Data Region Information PC

4 1.4 Town Project Basic Data get from planning & HCPT PC

5 1.5 CRLog Project Basic Data PC

6 1.6 LiveStatus Project Basic Data Active;Inactive;Propose Drop; PC

7 1.7 TX Cluster Project Basic Data get from Zhuchang PC

8 1.8 ProductID Project Basic Data get from site ID definition PC

9 1.9 TIServiceID Project Basic Data get from site ID definition PC

10 1.10 WPO Number Project Basic Data WPO Code or SPO Code The site under which WPO or SPO Code PC

Jabodetabek, West Java,Central Java, East Java, Bali Lombok, North Sumatera, Central Sumatera, South East Sumatera, South West Sumatera, West Kalimantan, Central Kalimantan, East Kalimantan, North Sulawesi, South Sulawesi

Original;Relocated;Original-Reactived;Relocated-Reactivated

Original: site/ link published in planning DB for the 1st timeOriginal-Reactived:the original site reactivatedRelocated: site/link relocate and change to another site IDRelocated-Reactivated:the relocated site reactivated

Propose Drop: not yet get CR, CR in processInactive: CR received

Page 12: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page12of20

SN Code Information Name Type Option Description PIC Data Provided / Document

1 2.1TKServiceID

PC

2 2.2 LocationType Green Field, Roof Top, In-Building Green field or Rooftop or In-building PC

3 2.3IBCType

Non-IBC;IBC-Self Build;IBC-Sharing;IBC-Multi Operator PC

4 2.4 SAM ID SAM ID from planning only the number PC

5 2.5 NE Longitude (°) Get information from planning PC/RNP

6 2.6 NE Latitude (°) Get information from planning PC/RNP

7 2.7 FE Longitude (°) Get information from planning PC/RNP

8 2.8 FE Latitude (°) Get information from planning PC/RNP

9 2.9

10 2.10

Self Build;TowerCo Sharing;Operator Sharing;B2S;OSP;MiniCME;Non-TK

Page 13: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page13of20

SN Code Information Name Type Option Description Data Provided / Document

1 lock uplink site code 0-Short Text

2 lock uplink site name 0-Short Text

3 lock link id 0-Short Text eg: 100001_100002

4 lock Link Capacity 0-Short Text

5 lock Site 1 Azimuth 0-Short Text NE site

6 lock Site 2 Azimuth 0-Short Text uplind link site, FE site

7 lock Site 1 Antenna diameter 0-Short Text

8 lock Site 2 Antenna diameter 0-Short Text

9 lock Site 1 Antenna height 0-Short Text

10 lock Site 2 Antenna height 0-Short Text

11 3.1 NE Site Tower Provider 5-Serial

12 3.2 NE Site Tower Height 3-Number Uplink FE Site Tower Height, unit: meter

13 3.3 Uplink FE Site Tower Provider 5-Serial

14 3.4 Uplink FE Site Tower Height 3-Number Uplink FE Site Tower Height, unit: meter

15 3.5 NE Site TX Priority 5-Serial Priority 1;Priority 2;Priority 3

16 3.6 NE Site TX Weight 3-Number

17 3.7 FE Site TX Priority 5-Serial Priority 1;Priority 2;Priority 3

18 3.8 FE Site TX Weight 3-Number

19 3.9 Uplink Sites Chain 1-Long Text

20 3.10 TNP Remark 1-Long Text

HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others

HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others

How many hops to on air site or BSC site, priority 1 = 1 hop, priority 2 = 2 hops, priority 3 = equal or more than 3 hops

the Site Weight equal to how many downlink sites (direct and indirect) including this site self

How many hops to on air site or BSC site, priority 1 = 1 hop, priority 2 = 2 hops, priority 3 = equal or more than 3 hops

the Site Weight equal to how many downlink sites (direct and indirect) including this site self

Please describe the uplink sites chain from RNC/BSC to this site. eg: RNC-Site ID1-Site ID2-Site ID3-This Site

Page 14: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page14of20

SN Code Information Name Type Option Description Data Provided / Document

1 4.1 CR No 0-Short Text

2 4.2 SAM ID 1-Short Text

3 4.3 SAM Diameter 3-Number

4 4.4 Nominal Longitude (°) 0-Short Text

5 4.5 Nominal Latitude (°) 0-Short Text

6 4.6 Final Longitude (°) 0-Short Text eg: 115.239889

7 4.7 Final Latitude (°) 0-Short Text eg: -8.657111

8 4.8 Co-site Type 5-Serial 2G Only;3G Only;2G and 3G;Microwave Only

9 4.9 NodeB Type 5-Serial Indoor; Outdoor

10 4.10 Building Height (m) 3-Number

11 4.11 3G Antenna Type-A 0-Short Text

12 4.12 3G Antenna Type-B 0-Short Text

13 4.13 3G Antenna Type-C 0-Short Text

14 4.14 3G Mechanical Downtilt-A (°) 3-Number

15 4.15 3G Mechanical Downtilt-B (°) 3-Number

16 4.16 3G Mechanical Downtilt-C (°) 3-Number

17 4.17 3G Antenna Azimuth-A (°) 3-Number

18 4.18 3G Antenna Azimuth-B (°) 3-Number

19 4.19 3G Antenna Azimuth-C (°) 3-Number

20 4.20 3G Antenna Height-A (m) 3-Number

21 4.21 3G Antenna Height-B (m) 3-Number

22 4.22 3G Antenna Height-C (m) 3-Number

23 4.23 2G Equipment Vendor 0-Short Text Huawei,ZTE,NSN

24 4.24 3G NodeB Model 0-Short Text eg: Huawei BTS 3900

25 4.25 3G NodeB Config 0-Short Text eg: S111

26 4.26 3G RNC Name 0-Short Text

27 4.27 3G RNC ID 0-Short Text

28 4.28 3G Cluster ID 0-Short Text

29 4.29 3G Cell ID-A 0-Short Text

30 4.30 3G Cell ID-B 0-Short Text

31 4.31 3G Cell ID-C 0-Short Text

32 4.32 3G RF Solution-Sector A 0-Short Text

33 4.33 3G RF Solution-Sector B 0-Short Text

34 4.34 3G RF Solution-Sector C 0-Short Text

35 4.35 3G Frequency Band (MHz) 5-Serial 850 MHz;2100 MHz;

36 4.36 3G RNP Remark 1-Long Text

The height of antenna including the building height for rooftop siteThe height of antenna including the building height for rooftop siteThe height of antenna including the building height for rooftop site

Page 15: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page15of20

Page 16: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page16of20

SN Code Information Name Type Option Description Data Provided / Document

1 5.1 CR No 0-Short Text

2 5.2 SAM ID 1-Short Text

3 5.3 SAM Diameter 3-Number

4 5.4 Nominal Longitude (°) 0-Short Text

5 5.5 Nominal Latitude (°) 0-Short Text

6 5.6 Final Longitude (°) 0-Short Text eg: 115.239889

7 5.7 Final Latitude (°) 0-Short Text eg: -8.657111

8 5.8 Co-site Type 5-Serial 2G Only;3G Only;2G and 3G;Microwave Only

9 5.9 BTS or NodeB Type 5-Serial Indoor; Outdoor

10 5.10 Building Height (m) 3-Number

11 5.11 2G Antenna Type-A 0-Short Text

12 5.12 2G Antenna Type-B 0-Short Text

13 5.13 2G Antenna Type-C 0-Short Text

14 5.14 2G Mechanical Downtilt-A (°) 3-Number

15 5.15 2G Mechanical Downtilt-B (°) 3-Number

16 5.16 2G Mechanical Downtilt-C (°) 3-Number

17 5.17 2G Antenna Azimuth-A (°) 3-Number

18 5.18 2G Antenna Azimuth-B (°) 3-Number

19 5.19 2G Antenna Azimuth-C (°) 3-Number

20 5.20 2G Antenna Height-A (m) 3-Number Unit: Meter

21 5.21 2G Antenna Height-B (m) 3-Number

22 5.22 2G Antenna Height-C (m) 3-Number

23 5.23 2G Equipment Vendor 0-Short Text Huawei,ZTE,NSN

24 5.24 2G BTS Model 0-Short Text eg: NSN BS 241

25 5.25 2G BTS Config 0-Short Text eg: S222

26 5.26 2G BSC Name 0-Short Text

27 5.27 2G BSC ID 0-Short Text

28 5.28 2G Cluster ID 0-Short Text

29 5.29 2G Cell ID-A 0-Short Text

30 5.30 2G Cell ID-B 0-Short Text

31 5.31 2G Cell ID-C 0-Short Text

32 5.32 2G RF Solution-Sector A 0-Short Text

33 5.33 2G RF Solution-Sector B 0-Short Text

34 5.34 2G RF Solution-Sector C 0-Short Text

35 5.35 2G Frequency Band (MHz) 5-Serial 900 MHz;1800 MHz

61 5.36 2G RNP Remark 1-Long Text

Page 17: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page17of20

Page 18: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page18of20

SN Code Information Name Type Option Description Data Provided / Document

1 6.1 Determinated SAAF Ref No. 0-Short Text

2 6.2 Candidate Site SN for SAAF 5-Serial Site Candidate Sequence Number for Determinated SAAF

3 6.3 Transmission Category 5-Serial BTS Site;Hub Site;Transmission Site Only

4 6.4 Site Land Space Size (L*W) (m) 0-Short Text Unit: Meter, eg: 30m * 20m

5 6.5 Building Height (m) 3-Number

6 6.6 Type of Transaction 5-Serial Operator Sharing;TowerCo Sharing;Lease;Purchase;HCPT Own;Others Lease (Direct Lease); Sharing ('indirect' lease); Sale&Purchase

7 6.7 Tower Provider 5-Serial

8 6.8 Tower Sharing Type 5-Serial Built to Suit (B2S);Collocation;Tower Transfer Site

9 6.9 Type of Site Ownership 5-Serial Direct Owner;Hibah/Inheritance;Company;Government;Military;Others

10 6.10 Type of Access Road Ownership 5-Serial Direct Owner;Hibah/Inheritance;Company;Government;Military;Others

11 6.11 Type of Lessor 5-Serial Natural Person;Private Entity;Other Entity

12 6.12 Type of Object 5-Serial Hak Milik;Girik;HGB;Strata Title;Hak Pkai;Others

13 6.13 Lease Duration (Year) 3-Number

14 6.14 Lease Price Net (IDR, per year) 0-Short Text Lease Price Net (IDR, per year), Including PPh

15 6.15 BAK Ref No. 0-Short Text

16 6.16 PKS Ref No. 0-Short Text

17 6.17 Community Permit Status 5-Serial In Progress;Obtained

18 6.18 IMB Status 5-Serial

19 6.19 IMB Certificate No. 0-Short Text

20 6.20 Detailed Address 1-Long Text Please input the detailed address of the site

21 6.21 Address Alias 0-Short Text Please input the address alias or shortened form of the site address

22 6.22 Customer PIC 0-Short Text Please input the name of customer PIC for this site

23 6.23 Zip Code 0-Short Text

24 6.24 Province 0-Short Text

25 6.25 County or City 0-Short Text

26 6.26 Floor Number 0-Short Text Please input which floor is the equipment located

27 6.27 Owner Name 0-Short Text

28 6.28 Owner Phone Number 0-Short Text

29 6.29 Owner Email 0-Short Text

30 6.30 Contact Person 0-Short Text

31 6.31 Contact Person Phone Number 0-Short Text

32 6.32 Contact Person Email 0-Short Text

33 6.33 Special Entrance Permit 4-Yes Or No

34 6.34 Access Hour 7*24 4-Yes Or No

35 6.35 Site Location Type 5-Serial Please indicate the site location type for the convenience of site access.

36 6.36 SITAC Remark 1-Long Text

Q;Candidate R;Candidate S;Candidate T;Candidate U;Candidate V;Candidate W;Candidate X;Candidate Y;Candidate Z;

HCPT;Protelindo;Indonesia Tower;Other Tower Provider(ToCo); Telkomsel;Telkom;XL;Indosat;Bakrie;NTS;Smart;STI;M8;Others

Built to Suit (B2S)-Dedicated for HCPT;Collocation-Share with the other operator;Tower Transfer Site-Tower usage transfer from TV, PLN, etc.

Private Property owned by Natural Person; Private Property owned by Private Entity; Inheritance (including granted property); Land/Building owned by Government (including military)

Private Property owned by Natural Person; Private Property owned by Private Entity; Inheritance (including granted property); Land/Building owned by Government (including military)

Natural Person (Perseorangan); Private Entity (Badan - Swasta); Other Entity, i.e Military, other government institution (Badan Lain)

Non Certificate Land (Tanah belum bersertifikat/Tanah Girik); Certificate with Freehold Title (Hak Milik); Certificate with Leasehold Title (HGB); Certificate with Right to Use Title (Hak Pakai)

Application submitted to Pemda;"Review in Progress" by Pemda;IMB Obtained

Should we need special entrance permit for access this site, if needed, please describe the detail information in the SA remark field.

Can this site be accessed in 7 days and 24 hours? If can't, please indicate the available access time in the SA remark field.

Green Field;Private House;Government;Company;School;Hospital;Appartment;Military;Others

Page 19: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page19of20

Page 20: RF Solution Rev1 20120321

document.xlsx Security Level:

04/07/2023 HUAWEI Confidential Page20of20

SN Code Information Name Type Option Description Data Provided / Document

1 7.1 Pole or Tower Type 5-Serial Mini tower for rooftop site, SST (Self support tower) for greenfield site.

2 7.2 Pole or Tower Height (m) 3-Number

3 7.3 Tower Legs Qty 3-Number

4 7.4 Pole or Tower Qty. 3-Number Unit: pcs

5 7.5 Tower Foundation Type 5-Serial

6 7.6 Diameter of Pile Found. (m) 3-Number

7 7.7 Length of Pile Found. (m) 3-Number

8 7.8 Tower Foundation Volume (m3) 0-Short Text Tower Foundation Volume (Foundation Space*H)(m3)

9 7.9 Shelter Type 5-Serial Big;Middle;Small;No Shelter

10 7.10 Shelter Size (L*W*H, m) 0-Short Text eg: L 6m*W 4m*H 2.7m

11 7.11 Fence Type 5-Serial Steel;Brick;Wooden;Others

12 7.12 Fence Length (m) 0-Short Text

13 7.13 Tower Pad Dimensions (L*W) 0-Short Text Tower Pad Dimensions (L*W)(Meter), eg: L 2m*W 2m

14 7.14 Access Road Dimensions (L*W) 0-Short Text Access Road Dimensions (L*W)(Meter), eg: L 15m*W 1m

15 7.15 0-Short Text

16 7.16 Equip or Shelter Pad Height (cm) 3-Number Unit: cm

17 7.17 Genset Pad Dimensions (L*W) 0-Short Text

18 7.18 Genset Pad Height (cm) 3-Number Unit: cm

19 7.19 Electricity Requirements (KVA) 3-Number

20 7.20 Power Supply by 5-Serial Building Facilities;PLN;PLN (New Trafo);Generator Set;Others

21 7.21 PLN Available or Not 4-Yes Or No

22 7.22 PLN Capacity (KVA) 3-Number

23 7.23 PLN Type 5-Serial Multiguna;KWH Meter(Permanent);Temporary;Others

24 7.24 PLN ID 0-Short Text

25 7.25 Need Genset or Not 4-Yes Or No

26 7.26 Genset Capacity (KVA) 3-Number

27 7.27 Air Condition Capacity (KVA) 3-Number

28 7.28 Quantity of Air Condition 3-Number Unit: Set

29 7.29 Air Warning Light 4-Yes Or No

30 7.30 CME Remark 1-Long Text

Pole;Monopole;Mini Tower;Wallmounting;SST-Light, SST-Medium, SST-Heavy, SST-Super Heavy;Others

Raft Foundation;Single Foundation;Pile Foundation;Steel Frame Foundation;Others

Equip or Shelter Pad Dimensions (L*W)

Equipment/Shelter Pad Dimensions (L*W)(Meter), Please indicate the Length and Width using unit meter. eg: L 2m*W 1m

Genset Pad Dimensions (L*W)(Meter), Please indicate the Length and Width using unit meter. eg: L 3m*W 2m