RGT Series SCR, Adjustable Speed Regenerative Drives for DC Brush Motors User’s Manual Models: RGT300U RGT310U RGT400U

Upload: others

Post on 21-Dec-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

RGT Series

SCR, Adjustable SpeedRegenerative Drivesfor DC Brush Motors

User’s M

anu

al

Models:RGT300URGT310URGT400U

Page 2: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

Copyright 2002 byMinarik Corporation

All rights reserved. No part of this manual may be reproduced or transmitted inany form without written permission from Minarik Corporation. The informationand technical data in this manual are subject to change without notice. MinarikCorporation and its Divisions make no warranty of any kind with respect to thismaterial, including, but not limited to, the implied warranties of its merchantabilityand fitness for a given purpose. Minarik Corporation and its Divisions assume noresponsibility for any errors that may appear in this manual and make nocommitment to update or to keep current the information in this manual.

Printed in the United States of America.

Page 3: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

i

Safety Warnings

• This symbol denotes an important safety tip or warning.Please read these sections carefully prior to performing any ofthe instructions contained in that section.

• Have a qualified electrical maintenance technician install, adjustand service this equipment. Follow the National Electrical Codeand all other applicable electrical and safety codes, including theprovisions of the Occupational Safety and Health Act (OSHA),when installing equipment.

• Reduce the chance of an electrical fire, shock, or explosion byproper grounding, over-current protection, thermal protection,and enclosure. Follow sound maintenance procedures.

It is possible for a drive to run at full speed as a result ofa component failure. Minarik strongly recommends theinstallation of a master switch in the main power input to stopthe drive in an emergency.

This drive is not isolated form earth ground. Circuitpotentials are at 115 VAC or 230 VAC above earth ground.Avoid direct contact with the printed circuit board or withcircuit elements to prevent the risk of serious injury or fatality.Use a non-metallic screwdrive for adjusting the calibrationtrimpots.

SHOCKHAZARD

AVOIDHEAT

KEEDR

OIDATION

Page 4: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

ii

Contents

Specifications 1

Dimensions 2

Regenerative Drives 4

Installation 6

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Heat sinking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Line fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Speed adjust potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Line frequency switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

+15V and –15V terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Voltage follower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Operation 16

Before applying power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Line starting and line stopping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Automatic restart upon power restoration . . . . . . . . . . . . . . . . . . . . . . . . .17

Regenerative deceleration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Regenerative braking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

SO502 and INHIBIT Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Calibration 21

MAXIMUM SPEED (MAX SPD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

ACCELERATION-DECELERATION (ACC–DEC) . . . . . . . . . . . . . . . . . . .22

FORWARD TORQUE (FWD TQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

REVERSE TORQUE (REV TQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

IR COMPENSATION (IR COMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Page 5: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

iii

Application Notes 27

Connection to other Minarik devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

Optional speed adjust potentiometer connections . . . . . . . . . . . . . . . . . . .29

Troubleshooting 32

Before troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

Replacement Parts 36

Unconditional Warranty back cover page

Tables

Table 1. Recommended Line Fuse Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Table 2. INHIBIT plug harnesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Table 3. Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Page 6: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

iv

Figures

Figure 1. RGT Series Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Figure 2. RGT-PCM Series Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Figure 3. Four Quadrant Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Figure 4. Speed Adjust Potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Figure 5. Speed Adjust Potentiometer Connections . . . . . . . . . . . . . . . . . .10

Figure 6. AC Line and Motor Connections . . . . . . . . . . . . . . . . . . . . . . . . . .11

Figure 7. - PCM CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Figure 8. Line Frequency Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Figure 9. +15V and –15V terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Figure 10. Voltage Follower Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Figure 11. RUN/STOP Switch for Regenerative Deceleration . . . . . . . . . . . .17

Figure 12. SO502 and INHIBIT Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Figure 13. Typical FWD TQ, REV TQ, and IR COMP Settings

(actual settings may vary with each application) . . . . . . . . . . . . .26

Figure 14. RGT Series Connections to DLC600 and PCM4 . . . . . . . . . . . . . .27

Figure 15. RGT Series Connection to 200-0386A

Limit Switch Logic Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Figure 16. Forward-Reverse Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Figure 17. Forward-Stop-Reverse Switch . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Figure 18. Independent Adjustable Speeds (Forward Direction) . . . . . . . . .30

Figure 19. Independent Forward and Reverse Speeds . . . . . . . . . . . . . . . . .30

Figure 20. Independent Forward and Reverse Speeds with a

Forward-Stop-Reverse Switch . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Page 7: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

1

SpecificationsMax.

Armature HP Range HP RangeCurrent with 115 VAC with 230 VAC

Model (Amps DC) Applied Applied

RGT300U 10.0 † 1/4–1 † n.a

RGT310U 3.0 1/20–1/8 n.a.

RGT400U 10.0 † n.a. 1/2–2 †

† Maximum armature current and horsepower range apply when drive is attached toadditional heat sink: Minarik part number 223-0235. Use heat sink when armaturecurrent is above 7 ADC.

AC Line Voltage (RGT300U/RGT310U) 115 VAC, ±10%, 50/60 Hz, single phase

AC Line Voltage (RGT400U) 230 VAC, ±10%, 50/60 Hz, single phase

Armature Voltage (RGT300U/RGT310U) 0–90 VDC

Armature Voltage (RGT400U) 0–180 VDC

Form Factor 1.37 at base speed

Acceleration Time Range 0.5–6 seconds

Deceleration Time Range 0.5–6 seconds

Analog Input Voltage Range (isolated; S0 to S2) –10 to +10 VDC

Input Impedance (S0 to S2) 32KΩLoad Regulation 1% of base speed or better

Vibration 0.5G max. (0–50 Hz)

0.1G max.(> 50 Hz)

Ambient Temperature Range 10°C–55°C

Page 8: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

2

Dimensions

0.92 [23]

1.86 [47]

8.90 [226]

8.38 [213]

4.75 [120]

3.53 [90]

AC

VO

LT

AG

E

AC

VO

LT

AG

E

AC

VO

LT

AG

E

AC

VO

LT

AG

E

L2

L1

SC

R505

C511

S0

L2L1

C504

C505

SC

R501

R504

-24V

S2

RB

1

MOV502

C503

60

HZ

SW

501

C502

C515

CO

M+

24V

INH

MOV501

FU

501

SO

502

T505

R501

C501

P502

C517

C516

P501C513

P503

C512

SC

R503

C519

T501

SC

R502

T502

C520

C521

SC

R504

R505

INH

IBIT

SC

R507

SO

503

T503

C522

SC

R506

R506

T504

R5

SC

R508

C510

C508

C509

Figure 1. RGT Series Dimensions

ALL DIMENSIONS IN INCHES [MILLIMETERS]

Page 9: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

3Dimensions

OUTMIN

OUTMAX

10-5

0M

A

1-5

MA

ADJUSTINPUTSIGNAL

121110987654321

COMPOL REVTPINPUT 1COM+15-15L2L1OUT2OUT1

5.21 [132]

3.20 [81]

1.86 [47]

0.92 [23]

8.90 [226]

8.38 [213]

4.75 [120]

3.53 [90]

FUSE

AC VOLTAGE

AC VOLTAGE

AC VOLTAGE

L1

GN

D

S0 S1

A1

A2

L2

L1

C50

4

C505

IC502

-15VS2 S3 RB2M

OV

50

2

C503

60HZ50HZ

C502

COM +24V

MO

V501

FU501

T505

C501

Figure 2. RGT-PCM Series Dimensions

ALL DIMENSIONS IN INCHES [MILLIMETERS]

Page 10: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

4

Regenerative Drives

Most non-regenerative, variable speed, DC drives control current

flow to a motor in one direction. The direction of current flow is the

same direction as the motor rotation. Non-regenerative drives

operate in Quadrant 1, and also in Quadrant 3 if the drive is

reversible (see Figure 3, page 4). Motors must stop before

reversing direction. Unless dynamic braking is used, non-

regenerative drives cannot oppose an overhauling load, and cannot

decelerate a load faster than coasting to a lower speed.

Regenerative drives operate in two additional quadrants: Quadrant

2 and Quadrant 4. In these quadrants, motor torque is in the

opposite direction of motor rotation.

Regenerative drives can reverse a motor without contactors,

switches, brake resistors, and inhibit plugs. They can also control

an overhauling load and decelerate a load faster than it would take

to coast to a lower speed.

Page 11: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

5Regenerative Drives

ARROWS IN OPPOSITE DIRECTION = REGENERATIVE ACTIONNOTE: ARROWS IN SAME DIRECTION = MOTOR ACTION

MOTORTORQUEROTATION

MOTOR

Quadrant III

Quadrant II

Quadrant IV

Quadrant I

Figure 3. Four Quadrant Operation

Page 12: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

Installation

Mounting

Drive components are sensitive to electrostatic fields. Avoid contact

with the circuit board directly. Hold the drive by the chassis only.

Protect the drive from dirt, moisture, and accidental contact.

Provide sufficient room for access to the terminal block and

calibration trimpots.

Mount the drive away from other heat sources. Operate

the drive within the specified ambient operating temperature range.

Prevent loose connections by avoiding excessive vibration

of the drive.

Mount the drive with its board in either a horizontal or vertical

plane. Six 0.188 inch (4.8 mm) wide slots in the chassis accept #8

pan head screws. Fasten either the large base or the narrow flange

of the chassis to the subplate.

The chassis must be earth grounded for noise suppression. To

ground the chassis, connect earth ground to the GND terminal.

6

Page 13: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

7Installation

Heat sinking

RGT Series drives require an additional heat sink when the

continuous armature current is above 7 ADC. Use Minarik heat sink

kit part number 223–0235. Use a thermally conductive heat sink

compound (such as Dow Corning® 340 Heat Sink compound)

between the drive chassis and the heat sink surface for optimum

heat transfer.

Wiring

• Use 18 AWG wire for speed adjust potentiometer wiring. Use 16

AWG wire for motor and AC line voltage wiring.

• Twist speed adjust potentiometer wires to avoid picking up

unwanted electrical noise. Use shielded cable if wires are longer

than 18 in. (46 cm).

• Keep speed adjust potentiometer wires away from power

carrying lines or sources of electrical noise that can cause erratic

operation. Never run speed adjust potentiometer wires in the

same conduit used for the motor and AC line voltage wires.

• It may be necessary to earth ground the shielded cable. If noise

is produced by devices other than the drive, ground the shield at

the drive end. If noise is generated by a device on the drive,

ground the shield at the end away from the drive. Do not ground

both ends of the shield.

Page 14: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

8 Installation

Line fusing

Minarik drives require external fuses for protection. Use fast acting

fuses rated for 250 VAC or higher, and approximately 150% of the

maximum armature current. Fuse L1 only when the line voltage is

115 VAC. Fuse both L1 and L2 when the line voltage is 230 VAC.

Table 1 lists the recommended line fuse sizes.

Table 1. Recommended Line Fuse Sizes90 VDC Motor 180 VDC Motor Max. DC Armature AC Line FuseHorsepower Horsepower Current (amps) Size (amps)

1/20 1/10 0.5 3

1/15 1/8 0.8 3

1/8 1/4 1.5 5

1/6 1/3 1.7 5

1/4 1/2 2.6 8

1/3 3/4 3.5 8

1/2 1 5.0 10

3/4 1 1/2 7.6 15

1 2 10 20

Minarik Corporation offers two fuse kits: part number 050–0069

(3–8A Fuse Kit) and 050–0073 (5–20A Fuse Kit). Both fuse kits

include a 1/8A pico fuse (part number 050–0064) which protects

the transformer and logic.

Page 15: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

9

Speed adjust potentiometer

Install the circular insulating disk between the mounting panel and

the 10K ohm speed adjust potentiometer (see Figure 4). Mount the

speed adjust potentiometer through a 0.38 inch (10 mm) hole with

the hardware provided. Twist the speed adjust potentiometer wire

to avoid picking up unwanted electrical noise. If potentiometer

leads are longer than 18 inches (46 cm), use shielded cable.

Figure 4. Speed Adjust Potentiometer

WIPERCW

W

SPEED ADJUSTPOTENTIOMETER

INSULATING DISK

PANEL

STARWASHER

NUT

MOUNT THROUGH A 0.38 IN. (10 MM) HOLE

Installation

Page 16: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

10 Installation

Connections

Figure 5. Speed Adjust Potentiometer Connections

(a) Bidirectional Operation

(b) Unidirectional Operation,Forward Direction

(c) Unidirectional Operation,Reverse Direction

10K OHM

SPEED ADJUST

POTENTIOMETER

CW

S0 S1 -15VS2 S3 RB1 RB2 +15V

CW

10K OHM

SPEED ADJUST

POTENTIOMETER

S0 S1 -15VS2 S3 RB1 RB2+15V

CW

10K OHM

SPEED ADJUST

POTENTIOMETER

S0 S1 -15VS2 S3 RB1 RB2+15V

Page 17: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

11

Figure 6. AC Line and Motor Connections

ASSUMPTIONS: Minarik drives supply motor voltage from

A1 and A2 terminals. It is assumed throughout this manual that,

when A1 is positive with respect to A2 , the motor will rotate

clockwise (CW) while looking at the output shaft protruding from

the front of the motor. If this is opposite of the desired rotation,

simply reverse the wiring of A1 and A2 with each other.

EARTH

GROUND

MASTER

POWER SWITCH

AC LINE VOLTAGE INPUT115 VAC (RGT300U/RGT310U)

230 VAC (RGT400U)

MOTOR

AC VOLTAGE

AC VOLTAGE

EARTH GND

DC VOLTAGE

DC VOLTAGE

GND

A1

A2

L2

L1

Installation

Page 18: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

Installation12

OUTMIN

OUTMAX

10-5

0M

A

4-2

0M

A

1-5

MA

ADJUSTINPUTSIGNAL

121110987654321

COMPOL REVTPINPUT 2INPUT 1COM+15-15L2L1OUT2OUT1

115 230

PREWIRED CONNECTIONS

REV

or

DIR

± 250VDC

10 - 50 mA4 - 20 mA1 - 5 mA± 25VDC

TO

L2

TO

L1

TO

S0

TO

S2

01

60HZ5V

SW501

C502

COM +24V

T5

05

C5

01

Figure 7. - PCM CONNECTIONS

Page 19: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

13

Line frequency switch

SW501 of the top board is the line frequency switch (see Figure 8).

Set the switch to 50HZ if the line frequency is 50 Hz, or to 60HZ if

the line frequency is 60 Hz.

Figure 8. Line Frequency Switch

AC VOLTAGE

AC VOLTAGE

EARTH GND

DC VOLTAGE

AC VOLTAGE

AC VOLTAGE

L2

L1

SCR505

C511

GN

DS0 S1

A1

A2

L2

L1

C50

4

C505

SCR501

R504

-24V

IC501IC502

S2 RB1

MO

V50

2

C503

SW501

60HZ

C502

C515

COM +24V INH

MO

V50

1

FU501

SO502

T505

R501C

50

1

P502

C517C516

P501

C513

C514 C518

P503

C512

SCR503

C519

T50

1

SCR502

T50

2

C520 C521

SCR504

R505

INHIBIT

P504

SCR

SO503

T50

3

C522

SCR506

R506

SW501

60HZ50HZ

LINE FREQUENCY SWITCH

Installation

Page 20: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

14 Installation

Figure 9. +15V and –15V terminals

+15V and –15V terminals

RGT Series drives can supply a regulated +15 and -15 VDC signal

(each sourcing 25 mA maximum) to isolated, external devices. See

Figure 9 for the location of these terminals.

Warning

Do not short the +15V and -15V terminals for any reason!Shorting these terminals may cause damage to the drive.

AC VOLTAGE

AC VOLTAGE

DC VOLTAGE

C511

S0 S1

A1

L2

L1

C50

4

C505

-24V

IC501IC502

-15VS3 RB1

MO

V50

2

C503

SW501

60HZ50HZ

C502

C515

COM +24V INH

FU501

SO502

T505

R501

P502

C517C516

P501

C513

C514 C518

P503

C512

C519

T50

1

T50

2

C520 C521

INHIBIT

P5

SO503

T50

3

-15VTERMINAL

+15VTERMINAL

Page 21: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

15

Voltage follower

The drive may be wired to follow a floating (isolated)

0 to ±10V signal that is isolated from earth ground instead of using

a speed adjust potentiometer. Connect the signal input to S2, and

the signal common to S0 (see Figure 10).

AC VOLTAGE

AC VOLTAGE

DC VOLTAGE

AC VOLTAGE

AC VOLTAGE

L2

L1

SCR505

C511

S0 S1

A1

L2

L1

C50

4

C505

SCR501

R504

-24V

IC501IC502

-15VS3 RB1

MO

V50

2

C503

SW501

60HZ50HZ

C502

C515

COM +24V INH

MO

V50

1

FU501

SO502

T505

R501

C50

1

P502

C517C516

P501

C513

C514 C518

P503

C512

SCR503

C519

T50

1SCR502

T50

2

C520 C521

SCR504

R505

INHIBIT

P5

SO503

T50

3

SCR506

R506

SIGNALCOMMON

±10 VDCSIGNAL

Figure 10. Voltage Follower Connection

Installation

Page 22: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

16

Operation

Before applying power

• Verify that no conductive material is present on the printed circuit

board.

• Verify that the AC supply is properly balanced.

• Check that the line frequency switch is set to the correct

position.

Startup

To start the drive:

1. Set the speed adjust potentiometer for zero speed.

2. Apply AC line voltage.

3. Slowly turn the speed adjust potentiometer clockwise or

counterclockwise to rotate the motor in the forward or reverse

direction. Continue until the desired speed is reached.

4. To decelerate the motor from set speed to a stop, reset the

speed adjust potentiometer for zero speed. To coast the motor

from set speed to a stop, remove AC line voltage from the drive .

Page 23: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

17Operation

Line starting and line stopping

When AC line voltage is applied to the drive, the motoraccelerates to the set speed. When AC line voltage is removed,the motor coasts to a stop. Line starting and line stopping(applying and removing AC line voltage) is recommended forstarting and stopping in emergency situations only. It is notrecommended for frequent starting and stopping.

Automatic restart upon power restoration

All drives automatically run to set speed when power is applied.

Wiring a latching relay into the AC line is one way to prevent

automatic restarting following a power outage.

Regenerative deceleration

Short terminals RB1 and

RB2 to regeneratively

decelerate a motor to a

stop (Figure 11). Calibrate

the acceleration and

deceleration time by

adjusting the ACC–DEC

acceleration trimpot.

DC VOLTAGE

S0 S1

A1

IC501IC502

-15VS3 RB1

2

SW501

60HZ50HZ

C515

RUN

STOP

Figure 11. RUN/STOP Switch forRegenerative Deceleration

Page 24: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

18 Operation

Regenerative braking

Short the INHIBIT terminals to regeneratively brake the motor (see

Figure 12, page 19, for INHIBIT terminal location). Reopening the

INHIBIT terminals causes the motor to accelerate to set speed.

Minarik Corporation offers two accessory plug harnesses for the

INHIBIT terminals:

Table 2. INHIBIT plug harnesses

Minarik

Part Number Description

201–0024 Inhibit plug with 18 in. (46 cm) wires

201–0079 Inhibit plug with 36 in. (91 cm) wires

Twist inhibit wires and separate them from other power-carrying

wires or sources of electrical noise. Use shielded cable if the inhibit

wires are longer than 18 inches (46 cm). If shielded cable is used,

ground only one end of the shield to earth ground. Do not ground

both ends of the shield.

Page 25: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

19

Figure 12. SO502 and INHIBIT Terminals

SO502 and INHIBIT Terminals

SO502 terminals are installed for future interfaces. Leave the

factory installed jumper (INH and -24 terminals) in place.

FUSE

AC VOLTAGE

AC VOLTAGE

AC VOLTAGE

L2

L1

SCR505

C511

S0

A1

L1

C5

04

SCR501

R504

-24V

S2

MO

V50

2

C503

60HZ

SW501

C502

C515

COM +24V INH

MO

V501

FU501

SO502

T5

05

R501

C5

01

P502

C517C516

P501

C513

P503

C512

SCR503

C519

T5

01

SCR502

T5

02

C520 C521

SCR504

R505

INHIBIT

P504 P505

SCR507

SO503

T5

03

C522

SCR506

R506

T5

04

R5

02

SCR508

C510

C509

SO502 TERMINALS

COM +24V IN

H -24

INHIBIT

INHIBIT TERMINALS

Operation

Page 26: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

20 Operation

Frequent regenerative deceleration or regenerative braking

produces high torque. This may cause damage to motors,

especially gearmotors that are not properly sized for the

application.

Warning

For frequent starts and stops, use regenerative decelerationor regenerative braking. Do not use any of these methodsfor emergency stopping. They may not stop a drive that ismalfunctioning. Removing AC line power (both L1 andL2) is the only acceptable method for emergencystopping.

Page 27: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

21

Calibration

RGT Series drives have five user adjustable trimpots: MAX SPD,

ACC–DEC, FORWARD TORQUE, REVERSE TORQUE, and

IR COMP. Each drive is factory calibrated to its maximum current

rating. Readjust the calibration trimpot settings to accommodate

lower current motors.

All trimpot settings increase with clockwise (CW) rotation, and

decrease with counterclockwise (CCW) rotation. Use a non-metallic

screwdriver for calibration. Each trimpot is identified

on the printed circuit board.

Page 28: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

Calibration22

MAXIMUM SPEED (MAX SPD)

The MAX SPD trimpot setting determines the motor speed when

the speed adjust potentiometer is turned full CW. It is factory set

for maximum rated speed.

To calibrate MAX SPD:

1. Set the MAX SPD trimpot full CCW.

2. Turn the speed adjust potentiometer full CW.

3. Adjust the MAX SPD trimpot until the desired maximum motor

speed is reached.

ACCELERATION-DECELERATION (ACC–DEC)

The ACC–DEC trimpot setting determines the time the motor takes

to accelerate to a higher speed, or decelerate to a lower speed, in

the forward or reverse direction within the limits of available torque.

ACC–DEC is factory set for its fastest forward acceleration and

deceleration time (full CCW).

Turn the ACC–DEC trimpot CW to increase the acceleration and

deceleration time, or CCW to decrease the acceleration and

deceleration time.

Page 29: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

23Calibration

FORWARD TORQUE (FWD TQ)

The FWD TQ trimpot setting determines the maximum torque for

accelerating and driving the motor in the forward direction. It also

sets the maximum torque for decelerating the motor in the reverse

direction. To calibrate FWD TQ, refer to Figure 13 on page 26, or

use the following procedure:

1. With the power disconnected from the drive, connect a DC

ammeter in series with the armature.

2. Set the FWD TQ trimpot to minimum (full CCW).

3. Set the speed adjust potentiometer to maximum forward speed.

4. Lock the motor shaft. Be sure that the motor is firmly mounted

to withstand maximum torque generated by the motor.

5. Apply line power. The motor should be stopped.

6. Slowly adjust the FWD TQ trimpot CW until the armature current

is 120% of motor rated armature current.

7. Set the speed adjust potentiometer to minimum.

8. Remove the power from the drive and unlock the motor shaft.

9. Remove the ammeter in series with the motor armature if it is

no longer needed and re-apply power to the drive.

Warning

FORWARD TORQUE should be set to 120% of drivenameplate current rating. Continuous operation beyond thisrating may damage the motor. If you intend to operate therating, contact your Minarik representative for assistance.

Page 30: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

24 Calibration

REVERSE TORQUE (REV TQ)

The REV TQ trimpot setting determines the maximum torque for

accelerating and driving the motor in the reverse direction. It also

sets the maximum torque for decelerating the motor in the forward

direction. To calibrate REV TQ, refer to Figure 13 on page 26, or

use the following procedure:

1. With the power disconnected from the drive, connect a DC

ammeter in series with the armature.

2. Set the REV TQ trimpot to minimum (full CCW).

3. Set the speed adjust potentiometer to maximum forward speed.

4. Lock the motor shaft. Be sure that the motor is firmly mounted

to withstand maximum torque generated by the motor.

5. Apply line power. The motor should be stopped.

6. Slowly adjust the REV TQ trimpot CW until the armature current

is 120% of motor rated armature current.

7. Set the speed adjust potentiometer to minimum.

8. Remove the power from the drive and unlock the motor shaft.

9. Remove the ammeter in series with the motor armature if it is

no longer needed and re-apply power to the drive.

Warning

REVERSE TORQUE should be set to 120% of drivenameplate current rating. Continuous operation beyond thisrating may damage the motor. If you intend to operate therating, contact your Minarik representative for assistance.

Page 31: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

25

IR COMPENSATION (IR COMP)

The IR COMP trimpot setting determines the degree to which

motor speed is held constant as the motor load changes. It is

factory set for optimum motor regulation.

To calibrate IR COMP, refer to Figure 13 on page 26, or use the

following procedure:

1. Set the IR COMP trimpot to minimum (full CCW).

2. Set the speed adjust potentiometer until the motor runs at

midspeed without load (for example, 900 RPM for an 1800 RPM

motor). A hand held tachometer may be used to measure motor

speed.

3. Load the motor armature to its full load armature current rating.

The motor should slow down.

4. While keeping the load on the motor, rotate the IR COMP

trimpot until the motor runs at the speed measured in step 2. If

the motor oscillates (overcompensation), the IR COMP trimpot

may be set too high (CW). Turn the IR COMP trimpot CCW to

stablize the motor.

5. Unload the motor.

Calibration

Page 32: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

26

Figure 13. Typical FWD TQ, REV TQ, and IR COMP Settings(actual settings may vary with each application)

RGT400U

RGT310URGT300U

3.8 A ARM

180 VDC

3/4 HP

5 ADC

180 VDC

1 HP

7.5 ADC

180 VDC

1 1/2 HP

9.2 ADC

180 VDC

2 HP

IR COMPREV TQFWD TQ

0.56 ADC

90 VDC

1/20 HP

0.75 ADC

90 VDC

1/15 HP

1.3 ADC

90 VDC

1/8 HP

2.1 ADC

90 VDC

1/4 HP

IR COMP

IR COMP

REV TQ

REV TQ

FWD TQ

FWD TQ

2.7 ADC

90 VDC

1/4 HP

5 ADC

90 VDC

1/2 HP

7.0 ADC

90 VDC

3/4 HP

10 ADC

90 VDC

1 HP

IR COMP

IR COMP

REV TQ

REV TQ

FWD TQ

FWD TQ

Calibration

Page 33: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

27

Application Notes

Connections to other Minarik devices

Figure 14. RGT Series Connections to DLC600 and PCM4

SO S1

S2S2

S2 2

1RB1

RGT

SERIES

DRIVE

RGT

SERIES

DRIVE

DLC600

PCM4

Page 34: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

28 Application Notes

AC VOLTAGE

EARTH GND

DC VOLTAGE

DC VOLTAGE

GN

D

S0

A1

A2

L2

L1

50

4

505

-24V

IC501IC502

-15VS3

MO

V50

2

C503

+15V

SW501

60HZ50HZ

C502

C515

COM +24V INH

FU501

SO502

T505

R501

P501

C51

2

PO

TB

50

211

IC5

02

K5

01

12 13 15 1614

K5

02

15 -15V

16 S2

18 S0

LOGIC

BOARD

RGT

SERIES

DRIVE

Figure 15. RGT Series Connection to 200-0386A Limit Switch Logic Board

Page 35: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

29

Use a single pole, two position switch with a single speed adjust

potentiometer to plug reverse the motor (Figure 16).

Use a single pole, three position switch with a single speed adjust

potentiometer to stop a motor between reversal (Figure 17). Set the

switch to the center position to decelerate the motor to a stop.

S0

S1

S2

S3

REV

FWD

CW

10K OHM

SPEED ADJUST

POTENTIOMETER

S0

S1

S2

S3

REV

FWD

CW

10K OHM

SPEED ADJUST

POTENTIOMETER

STOP

Optional speed adjust potentiometer connections

Figure 17. Forward-Stop-Reverse Switch

Application Notes

Figure 16. Forward-Reverse Switch

Page 36: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

30

Connect two speed adjust potentiometers with a single pole two

position switch to select between two independent speeds shown

in the forward direction (Figure 18). The speed adjust

potentiometers can be mounted at two separate operating stations.

S0

S1

S2

SPEED 1

P1

20K

SPEED 2

P2

20K

CW CW

S0

S1

S2

REVERSE

REV

10K

FORWARD

FWD

10K

CW CW

S3

Connect two speed adjust potentiometers as shown in Figure 19 to

select between independent forward and reverse speeds.

Figure 19. Independent Forward and Reverse Speeds

Application Notes

Figure 18. Independent Adjustable Speeds (Forward Direction)

Page 37: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

31

Use a single pole, three position switch to stop the motor when the

switch is in the center position (Figure 20).

S0

S1

S2

REVERSE

REV

10K

FORWARD

FWD

10K

CW CW

S3

STOP

Figure 20. Independent Forward and Reverse Speeds with aForward-Stop-Reverse Switch

Application Notes

Page 38: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

32

Before troubleshooting

Perform the following steps before starting any procedure in this

section:

1. Disconnect AC line voltage from the drive.

2. Check the drive closely for damaged components.

3. Check that no conductive or other foreign material has becomelodged on the printed circuit board.

4. Verify that every connection is correct and in good condition.

5. Verify that there are no short circuits or grounded connections.

6. Check that the drive’s rated armature outputs are consistentwith the motor ratings.

7. Check that the line frequency switch is properly set.

Warning

Dangerous voltages exist on the drive when it is powered.When possible, disconnect the AC line voltage from the drivewhile troubleshooting. Be alert. High voltages can causeserious or fatal injury.

Troubleshooting

Page 39: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

33Troubleshooting

External line fuse blows. 1. Line fuse is thewrong size.

2. Motor cable orarmature is shortedto ground.

3. Nuisance trippingcaused by acombination ofambient conditionsand high-currentspikes (i.e.reversing).

1. Check that the linefuse is correct for themotor size.

2. Check motor cableand armature forshorts.

3. Add a blower to coolthe drivecomponents;decrease FWD TQand REV TQsettings, or resizemotor and drive foractual load demand,or check forincorrectly alignedmechanicalcomponents or“jams”.

Problem PossibleCauses

SuggestedSolutions

Page 40: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

34 Troubleshooting

External line fuse doesnot blow, but the motordoes not run.

1. Speed adjustpotentiometer orvoltage referencesignal is set to zerospeed.

2. Speed adjustpotentiometer is notconnected to driveinput properly;connections areopen.

3. INHIBIT terminals arejumpered.

4. S2 is shorted to S0.

5. Drive is in currentlimit.

6. Drive is not receivingAC line voltage.

7. Motor is notconnected.

1. Increase the speedadjust potentiometeror voltage referencesignal setting.

2. Check connections toinput. Verify thatconnections are notopen.

3. Remove jumper fromthe INHIBITterminals.

4. Remove short.

5. Verify that motor isnot jammed.Increase FWD TQand REV TQ settingif they are set toolow.

6. Apply AC line voltageto L1 and L2.

7. Connect motor to A1and A2.

Problem PossibleCauses

SuggestedSolutions

Page 41: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

35

For additional assistance, contact your local Minarik Distributor, or the

factory direct: PHONE (800) MINARIK or (800) 646-2745

FAX (800) 394-6334

Motor runs too fast.

Motor will not reach thedesired speed.

Motor pulsates orsurges under load.

Motor makes ahumming or buzzingnoise.

1. MAX SPD notcalibrated.

1. MAX SPD setting istoo low.

2. IR COMP setting istoo low.

3. Motor is overloaded.

1. IR COMP is set toohigh.

2. Motor bouncing inand out of currentlimit.

1. Line frequencyswitch is set forwrong frequency.

1. Calibrate MAX SPD.

1. Increase MAX SPDsetting.

2. Increase IR COMPsetting.

3. Check motor load.Resize the motor ifnecessary.

1. Adjust the IR COMPsetting slightly CCWuntil the motor speedstabilizes.

2. Make sure motor isnot undersized forload; adjust FWD TQand REV TQ trimpotCW.

1. Set line frequencyswitch for correctfrequency.

Problem PossibleCauses

SuggestedSolutions

Troubleshooting

Page 42: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

36

Replacement Parts

Replacement parts are available from Minarik Corporation and its

distributors for this drive series.

Table 3. Replacement Parts

Model No. Symbol Description Minarik P/NRGT300U, RGT300U-PCM

R503 0.01W, 5 W Resistor 032–0129SCR501–508 800 V, 25 A SCR 072–0042T501 3FS–436 Transformer 230–0071

10KW Potentiometer Kit 202–0003Chassis 223-0258

RGT310U, RGT310U-PCMR503 0.1W, 5 W Resistor 032–0100SCR501–508 800 V, 25 A SCR 072–0042T501 3FS–436 Transformer 230–0071

10KW Potentiometer Kit 202–0003Chassis 223-0258

RGT400U, RGT400U-PCMR503 0.01W, 5 W Resistor 032–0129SCR501–508 800 V, 25 A SCR 072–0042T501 3FD–436 Transformer 230–0072

10KW Potentiometer Kit 202–0003Chassis 223-0258

Fuse Kits 63 mA Pico Fuse 050-0081Inhibit Plugs 2-Pin Jumper Harness 201-0085

Page 43: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

37

NOTES

Page 44: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

NOTES

38

Page 45: RGT Series...Armature HP Range HP Range Current with 115 VAC with 230 VAC Model (Amps DC) Applied Applied RGT300U 10.0 † 1/4–1 † n.a RGT310U 3.0 1/20–1/8 n.a. RGT400U 10.0

Unconditional WarrantyA. Warranty - Minarik Corporation (referred to as “the Corporation”) warrants that itsproducts will be free from defects in workmanship and material for twelve (12) months or3,000 hours, whichever comes first, from date of manufacture thereof. Within thiswarranty period, the Corporation will repair or replace, at its sole discretion, suchproducts that are returned to Minarik Corporation, 901 East Thompson Avenue,Glendale, CA 91201-2011 USA.

This warranty applies only to standard catalog products, and does not apply to specials.Any returns for special controls will be evaluated on a case-by-case basis. TheCorporation is not responsible for removal, installation, or any other incidental expensesincurred in shipping the product to and from the repair point.

B. Disclaimer - The provisions of Paragraph A are the Corporation’s sole obligation andexclude all other warranties of merchantability for use, express or implied. TheCorporation further disclaims any responsibility whatsoever to the customer or to anyother person for injury to the person or damage or loss of property of value caused byany product that has been subject to misuse, negligence, or accident, or misapplied ormodified by unauthorized persons or improperly installed.

C. Limitations of Liability - In the event of any claim for breech of any of theCorporation’s obligations, whether express or implied, and particularly of any other claimor breech of warranty contained in Paragraph A, or of any other warranties, express orimplied, or claim of liability that might, despite Paragraph B, be decided against theCorporation by lawful authority, the Corporation shall under no circumstances be liablefor any consequential damages, losses, or expense arising in connection with the use of,or inability to use, the Corporation’s product for any purpose whatsoever.

An adjustment made under warranty does not void the warranty, nor does it imply anextension of the original 12-month warranty period. Products serviced and/or partsreplaced on a no-charge basis during the warranty period carry the unexpired portion ofthe original warranty only.

If for any reason any of the foregoing provisions shall be ineffective, the Corporation’sliability for damages arising out of its manufacture or sale of equipment, or use thereof,whether such liability is based on warranty, contract, negligence, strict liability in tort, orotherwise, shall not in any event exceed the full purchase price of such equipment.

Any action against the Corporation based upon any liability or obligation arisinghereunder or under any law applicable to the sale of equipment or the use thereof, mustbe commenced within one year after the cause of such action arises.