BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL19002-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Enviralum Industies Inc Address/Phone/Email 5100 NW 72 Ave. Bldg C Miami, FL 33166 (305) 752-4411 [email protected] Authorized Signature Frank Messa [email protected] Technical Representative Frank Messa Address/Phone/Email 5100 NW 72 Ave. Bldg. C Miami, FL 33166 (305) 752-4411 [email protected] Quality Assurance Representative Address/Phone/Email Category Panel Walls Subcategory Storefronts Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Javad Ahmad Florida License PE-70592 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ammad Riaz, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL19002_R1_COI_SS - ENV-450 Alum. Window Wall System (LMI)-CI 2017.pdf Referenced Standard and Year (of Standard) Standard Year AAMA 501 2005 TAS 201 1994 TAS 202 1994 TAS 203 1994 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw... 1 of 2 1/6/2018, 8:21 AM

Upload: others

Post on 19-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search

Product ApprovalUSER: Public User

Product Approval Menu > Product or Application Search > Application List > Application Detail

FL # FL19002-R1

Application Type Revision

Code Version 2017

Application Status Approved

Comments

Archived

Product Manufacturer Enviralum Industies Inc

Address/Phone/Email 5100 NW 72 Ave.Bldg CMiami, FL 33166(305) [email protected]

Authorized Signature Frank [email protected]

Technical Representative Frank Messa

Address/Phone/Email 5100 NW 72 Ave. Bldg. CMiami, FL 33166(305) [email protected]

Quality Assurance Representative

Address/Phone/Email

Category Panel Walls

Subcategory Storefronts

Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed FloridaProfessional Engineer

Evaluation Report - Hardcopy Received

Florida Engineer or Architect Name who developed theEvaluation Report

Javad Ahmad

Florida License PE-70592

Quality Assurance Entity National Accreditation and Management Institute

Quality Assurance Contract Expiration Date 12/31/2018

Validated By Ammad Riaz, P.E.

Validation Checklist - Hardcopy Received

Certificate of Independence FL19002_R1_COI_SS - ENV-450 Alum. Window Wall System (LMI)-CI2017.pdf

Referenced Standard and Year (of Standard) Standard Year

AAMA 501 2005

TAS 201 1994

TAS 202 1994

TAS 203 1994

Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...

1 of 2 1/6/2018, 8:21 AM

Equivalence of Product StandardsCertified By

Sections from the Code

Product Approval Method Method 1 Option D

Date Submitted 08/18/2017

Date Validated 08/18/2017

Date Pending FBC Approval 08/23/2017

Date Approved 10/10/2017

Summary of Products

FL # Model, Number or Name Description

19002.1 ENV-450 Aluminum Window WallSystem

Large missile impact resistant aluminum window wall systemw/ or w/o thermal break.

Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +100/-131Other: See installation drawings W15-74 for span vs. load

combinations and installation details.

Installation InstructionsFL19002_R1_II_SS - ENV-450 Alum. Window Wall System(LMI) - 2017 DWG W15-74.pdf Verified By: Javad Ahmad 70592 Created by Independent Third Party: YesEvaluation ReportsFL19002_R1_AE_SS - ENV-450 Alum. Window Wall System(LMI)-PAE 2017.pdf Created by Independent Third Party: Yes

Back Next

Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824

The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement

Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mailto this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), FloridaStatutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails providedmay be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the

Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .

Product Approval Accepts:

Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...

2 of 2 1/6/2018, 8:21 AM

9360 Sunset Drive STE 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | [email protected]

PRODUCT APPROVAL EVALUATION RULE CHAPTER #61G20-3 • METHOD 1 OPTION D

FL 19002 Date: 8/16/17

Detailed Product Description: Manufacturer: ENVIRALUM INDUSTRIES, INC Manufacturer Address: 5100 NW 72ND AVENUE, BLDG C. MIAMI, FL 33166 Model Name: SERIES “ENV-450” ALUMINUM WINDOW WALL SYSTEM Maximum Frame Width: 72” Maximum Frame Height: 144” Maximum Load: +100 PSF, -131 PSF (Large Missile Impact) Installation Drawings # W15-74

The above maximum parameters do not occur simultaneously. See charts on installation drawings for combination of spans vs. loads.

Comparative analysis used X Yes No Mandatory Tests (Tested in accordance with AAMA 501/101/I.S.2/NAFS-02/TAS-202)

TEST DESCRIPTION TEST LOCATION REPORT DATE

TEST REPORT #

Test Sealed by

ASTM E283 Air Infiltration Leakage

Fenestration Testing Laboratory

04/23/2012 FTL-6678 Marlin D. Brinson, PE

ASTM E331 OR ASTM 547

& TAS 202

Water Penetration

Fenestration Testing Laboratory

04/23/2012 FTL-6678 Marlin D. Brinson, PE

ASTM E330 & TAS 202

Uniform Static Air Press.

Fenestration Testing Laboratory

04/23/2012 FTL-6678 Marlin D. Brinson, PE

Supplemental Tests (Tested in accordance with TAS-201 and TAS-203) TEST DESCRIPTION TEST LOCATION TEST

REPORT DATE

TEST REPORT #

Test Sealed by

FBC 1626.2 (TAS 201 & 203)

ASTM E1886/1996 ANSI Z97.1

Large Missile Impact & Cyclic

Level D/E

Fenestration Testing Laboratory

Blackwater Testing Inc

04/23/2012

04/06/2017 06/09/2017

FTL-6678

BT-ENI-16-003 BT-ENI-16-003B

Marlin Brinson, PE Constantin Bortes, PE

Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the above product conforms to the requirements of the 2017 Florida Building Code.

Evaluation Report Engineer: Javad Ahmad PE # 70592 Al-Farooq Corporation EB # 3538

This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements.

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017

Sealed: 08/18/2017