Packaging Dynamics Laboratory 78 Lomb Memorial Drive Rochester, New York 14623-5603 Phone: (585) 475-5005 Fax: (585) 475-5555 Email: [email protected]
Rochester Institute of Technology
RIT Packaging Dynamics Lab Report
S-One Holdings Corp.5466 S. Westridge Dr. Test Number: 2171 New Berlin, WI 53151 Date Tested: 4/29/19
Requested By: Mr. Mark Buchman Phone No: 414.881.7110 Email: [email protected]
Test Performed: Environmental Conditioning and Vibration
Sample Set 1A: Description: Case with insert Dimensions: 11” x 8+1/4” x 8+1/2” Weight: 20 lbs. Quantity: 1
Sample Set 1B: Description: Case without insert Dimensions: 11” x 8+1/4” x 8+1/2” Weight: 20 lbs. Quantity: 1
Bottle to bottle abrasion simulation • Package shall be preconditioned for 72 hours at 40˚C, 80% RH (simulating 26 days of shelf
life, based off of ASTM F1980)• After completion of conditioning packages will be vibrated for a duration of 5 hours using
ISTA 2A vibration profile at 1.15 Grms (simulating 300 miles of very rough road per hour of testing)
o Testing will be paused every hour to evaluate the progression of label degradation if any
Packaging Description
Test Procedure
Client:
Each sample set consists of twelve 16 oz. glass juice bottles, filled with water and capped. Labels were applied to the exterior of the bottles (see photos pages 4 & 5). Sample set 1A was tested with a chipboard partition between the bottles. Sample set 1B was tested without a partition (see photos page 3). Both sets of 12 bottles include two bottles with each of the following labels:
• UPM Raflatac SY14X clear OPP• UPM Raflatac SY931M Silver Metalized OPP• UPM Raflatac SY393L Matte White OPP
Labels were printed on an HP Indigo 6900 press, primed inline with Michelman DigiPrime 680. The printed labels were coated with:
• Kustom LP KKLP 200 Silicone Free Gloss UV coating• Kustom LP KKLP 405 Silicone Free, Benzophenone Free Matte UV coating
Both coatings were treated with Michelman DigiGuard 901 UV OPV Strengthener.
mailto:[email protected]
-
1. Following the test, the bottles were inspected for obvious signs of external damage. No major externaldamages were observed.
2. Following testing, labels were inspected for scuffing. No scuffing or peeling seen.
3. Test samples sent back to client for any further post-inspection.
For conclusions regarding post-test results, please contact Mark Buchman at [email protected].
Testing performed by: M. Dickerson, S. Hung-Krause, M. Michael, J. Mueller, P. Spiridigloizzi, S. Cammilleri and J. Vakiener
Mitchel Dickerson, CPLP Rochester Institute of Technology Technician, RIT Packaging Dynamics Lab (585) 475-2871
VIBRATION MACHINE TEST SYSTEM TOUCH TEST ELECTRONICS – MM804 LANSMONT CORPORATION, MODEL 7000-10
RELATIVE HUMIDITY & TEMPERATURE CHAMBER HONEYWELL/PARAMETER GENERATION & CONTROL, INC MODEL #AA-5474, 400-700 CFM CLIMATE-LAB AA
Observations
Conclusion
Equipment List
mailto:[email protected]
-
S-One Holdings Corp. Pre-Test
View of the case with inserts before testing
View of case without inserts
-
S-One Holdings Corp. With Insert Post-Test
No damages found to any labels
-
S-One Holdings Corp. Without Insert
Post-Test
No damages found to any labels
-
Rochester Institute of TechnologyPackaging SciencePackaging Dynamics Lab78 Lomb Memorial DriveRochester, NY 14623-56227
2172 Technician M. Dickerson
Sample Set Product #1 N/A2 N/A
Sample Set Sample Weight (lb.) 1 11 8+1/4 8+1/2 202 11 8+1/4 8+1/2 20
Condition DurationSample Set Humidity (hrs.)
All 80% 72
Vibration TimeSample Set Grms (hr):(min):(sec)
All 1.15 5:00:00
RIT Test Number
HP Indigo Labels and PackagingJudy Finlay [email protected]
ClientContact
ISTA 2A StandardMonday, April 29, 2019
Test Date
Sample Size (L" x W" x D")
2
Product Description
Sample Size
Sample Qty1
Sample #1
With insert1 Without insert
1
Random (ISTA 2A Vibration)Orientation
Face 3Sample #
All
Atmospheric Conditioning1Sample #
All
2
Temperature40C
mailto:[email protected]
-
Control & Input Data C:\TTV2\Bin\Archive\2018\_AutoSave_2019-04-29_13-10-45.DRN1:10:45 PM
Apr-29-2019
TestQ ID: 2171 HP Indigo Control: 1.149 G rms Elapsed: 5 hr 0 min 0 sec Profile: 1 of 1Profile ID: ISTA (1C, 1D, 1E, 1F, 1G, 1H, 2A, 2B Demand: 1.146 G rms - 100.0% Remaining: 0 hr 0 min 0 sec Total: 0 hr 0 min 0 sec
1 2 10 20 100 2001e-006
1e-005
0.0001
0.001
0.01
0.1
Frequency (Hz)
PSD(G²/Hz)
ControlCh 1
2171 Test Report.pdf2172 ISTA 2A Procedure.pdfISTA 2A
5 hr vibe.pdf