riverton apartments 10-unit apartments...van nuys, ca 61406 818-344-5787. daba engineering group...
TRANSCRIPT
AFCO Design, Inc.10635 Santa Monica Blvd #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
5254 NORTH RIVERTON AVE. NORTH HOLLYWOOD, CA 91601 . .
JOB ADDRESS
RIVERTON EMPIRE PROPERTY, LLC 550 S. HILL ST. #625 LOS ANGELES, CA 90013 . .
OWNER
AFCO DESIGN, INC. FRANK AFARI 10635 Santa Monica Blvd #190 LOS ANGELES, CA 90025 310-557-1031
ARCHITECT
DSL STRUCTURAL ENGINEERS, INC. DANTE LOTA 19325 TRENTHAM AVE. CERRITOS, CA 90703 562-787-3095
STRUCTURAL ENGINEER
SURVEYOR JACK LITTLE COMPANY, INC. 17620 SHERMAN WAY SUIT 218 VAN NUYS, CA 61406 818-344-5787 .
DABA ENGINEERING GROUP RICHARD CARRIZOSA 15206 GRAYSTONE AVE. NORWALK, CA 90650 562-375-8991
SOIL ENGINEER
ECCO ENGINEERING . 726 W. BROADWAY AVE. SUITE A GLENDALE, CA 91204 818-507-5607
ELECTRICAL ENGINEER
MNS ENGINEERING, INC. MEHRDAD ROKNI 1600 SAWTELLE BLVD. #300 LOS ANGELES, CA 90025 310-473-8494 .
MECHANICAL
SUSAN Mc EOWEN LANDSCAPE ARCH SUSAN Mc EOWEN 32297 BIG OAK LANE CASTAIC, CA 91384 661-294-3753
LANDSCAPE ARCHITECT
CDRAWN BY: F.A.
DATE: 06-12-2017
SCALE: AS SHOWN
THIS DOCUMENT IS THE PROPERTY ANDCOPY RIGHT OF AFCO DESIGN, INC. ANDSHALL NOT BE USED ON ANY OTHER WORK,BE REPRODUCED OR DISCLOSED TOOTHERS EXCEPT BY LETTER AUTHORIZATIONFROM AFCO DESIGN, INC.
NEW 4-STORY TYPE V-A, 10-UNIT APARTMENTHOUSE OVER 1-LEVEL BASEMENT PRIVATEGARAGE
PROJECT DESCRIPTION
TRACT LICENSED SURVEY BLOCK NONE LOT FR34 MAP BOOK L S 13-16 ARB NONE MAP SHEET 171B173APN 2416-024-002C.D. 02T.G. PAGE 563-GRID A2
LEGAL DESCRIPTION
OCCUPANCY #1 OCCUPANCY #2 OCCUPANCY #3TYPE OF CONSTRUCTIONOCCUPANCYNO. OF STORIES
ALLOWABLE FLOOR AREA
W=(30' (12 STREET WIDTH)X200')/200'=30'FRONTAGE INCREASE: I f=[F/P-0.25]W/30If=[31'/273'-0.25]30 /30=0.136 ASSUME 0.0AREA MODIFICATION: A a={At+[AtXIf]+[AtXIs]}Aa={12,000+[12,000X0]+[12,000X2]}=36,000 SQ. FT. >4,688 S.F. (PROVIDED)
ALLOWABLE AREA PER STORYMAX. BUILDING AREA:> 1 STORY: ALLOWABLE X2
OCCUPANCY SEPARATION
VAR-24
HEIGHT (ALLOWABLE) 50'+10'=60'12,000
1 BASEMENT
IAS-2
UNLIMITEDUNLIMITED
SECTION 506.2.1
SECTION 506.2
TABLE 503TABLE 503/ 504.2
TABLE 503
SECTIONS 506.1506.2, 506.3
SECTION 506.4.1
SECTION 510.2
CODE SECTION
36,000 SQ. FT.
72,000 SQ. FT.3-HR
UNLIMITED
UNLIMITED
BUILDING ELEMENT
PRIMARY STRUCTURAL FRAME
BEARING WALLSEXTERIORINTERIOR
NONBEARING WALLS AND PARTITIONSEXTERIOR
NONBEARING WALLS AND PARTITIONSINTERIOR
FLOOR CONSTRUCTION AND SECONDARYMEMBER
ROOF CONSTRUCTION AND SECONDARYMEMBER
SHAFT RATING 2
TYPE I
3
33
1
0
2
1.5
TYPE VA
1
11
1
0
1
1
FIRE RESISTANCE RATING REQUIREMENTS FORBUILDING ELEMENTS (HOURS)DEFERRED SUBMITTAL ITEMS:
DEFERRED SUBMITTAL ITEMS SHALLCOMPLY WITH CBC SECTION106.4.4.2. SUBMITTAL DOCUMENTSFOR DEFERRED SUBMITTAL ITEMSSHALL BE SUBMITTED TO THEARCHITECT (STRUCTURAL ENGINEER)FOR REVIEW WITH THE GENERALCONFORMANCE TO CONTRACTDOCUMENTS. PROVIDE APROFESSIONAL ENGINEER'SSIGNATURE AND SEAL IN THE STATEWHERE THE PRODUCT SITE OCCURS.THE DEFERRED SUBMITTAL ITEMSSHALL NOT BE INSTALLED UNTIL THEIRDESIGN AND SUBMITTAL DOCUMENTSHAVE BEEN REVIEWED BY THEBUILDING OFFICIAL. DEFERREDSUBMITTAL ITEMS ARE AS FOLLOWING:
A. ELEVATOR ANCHOR SYSTEMB. ATS SYSTEM (HOLD DOWNS)
OPEN SPACE REQUIREMENTS SEC. 12.21.G2
CONSTRUCTION TYPE SUMMARY
PROJECT SUMMARY
PARKING REQUIREMENTS PER CITY OF LA
REQUIRED BEFORE DEDUCTION FOR BICYCLEPARKING
RESIDENTIAL* 10X2.0 20
*ALL ASSIGNEDTOTAL 20
REQUIRED PARKING WITH UP TO 10%DEDUCTION PER (ORD. 182386) BICYCLEORDINANCE (20)=2 PARKING REDUCTIONACTUAL DEDUCTION 2/20=10.%
RESIDENTIAL 18TOTAL 18
PROVIDEDRESIDENTIAL
HANDICAP (1%) 01 REQUIREDSTANDARD 09 REQUIRED
COMPACT 08 REQUIREDCOMPACT 02 NON-REQUIRED
TOTAL 20GUEST PARKING NONE REQUIRED
NONE PROVIDED
BICYCLE PARKING CALCULATIONS:REQUIRED
RESIDENTIALLONG TERM 10 (100%)SHORT TERM 02 (10%)TOTAL 12
PROVIDEDRESIDENTIAL
LONG TERM 10SHORT TERM 02TOTAL 12
CAR CHARGER CALCULATIONS:20X5%=1 CAR CHARGER REQUIREDAND PROVIDED
NUMBER OF UNITS: 10ZONING CODE HEIGHT LIMIT: 45'MAXIMUM BUILDING AREA ALLOWED: 3:1 FAR
LOT AREA (BEFORE DEDICATION): 8,109.4 SQ. FT.LOT AREA (AFTER DEDICATION) 7,929.4 SQ. FT.
ALLOWABLE BUILDABLE AREA:[(60'-10')X(132'-30')]X3=15,300 SQ.FT.
ACTUAL BUILDING AREA: 15,176< 15,300 OK
BUILDING AREA: OCC.
USE OCCUPANCY LOAD AREA
FIRST FLOOR:RESIDENTIAL R-2 1/200 (23) 4,514 SQ. FT.EXTERIOR WALLS/ SHAFT/ STAIRS/ VENTS <250> SQ. FT.
TOTAL AREA: 4,264 SQ. FT.
SECOND FLOOR:RESIDENTIAL R-2 1/200 (23) 4,688 SQ. FT.EXTERIOR WALLS/ SHAFT/ STAIRS/ VENTS <250> SQ. FT.
TOTAL AREA: 4,438 SQ. FT.
THIRD FLOOR:RESIDENTIAL R-2 1/200 (23) 4,688 SQ. FT.EXTERIOR WALLS/ SHAFT/ STAIRS/ VENTS <250> SQ. FT.
TOTAL AREA: 4,438 SQ. FT.
FOURTH FLOOR:RESIDENTIAL R-2 1/200 (6) 1,286 SQ. FT.EXTERIOR WALLS/ SHAFT/ STAIRS/ VENTS <125> SQ. FT.
TOTAL AREA: 1,161 SQ. FT.
TOTAL RESIDENTIAL AREA (BLD'G CODE): 14,301 SQ. FT.TOTAL RESIDENTIAL AREA (ZON'G CODE): 15,176 SQ. FT.TOTAL RESIDENTIAL AREA (SCHOOL FEE):15,176 SQ. FT.
GARAGE AREA:
(BASEMENT) S-2 1/200 (38) 7,627 SQ. FT.TOTAL 7,627 SQ. FT.
ZONING: R3-1VL
DENSITY8,109.4/800=10 UNITS
BUILDING SUMMARY PARKING SUMMARY
DESCRIPTIONSHEET DESCRIPTIONSHEET
SHEET INDEX
A-13A-14A-15A-16
A-05
A-12
A-07A-06
A-10A-11
A-09A-08
A-01
CS
A-03A-04
A-02
A-17A-18
TYPICAL DETAILS
TYPICAL DETAILS
DOOR/ FINISH SCHEDULES
SURVEYSITE PLAN
COVER SHEET
ROOF PLAN
1/4" THIRD FLOOR PLAN
TYPICAL DETAILS
SECTIONS
ELEVATIONS WEST- SOUTH
TYPICAL DETAILS
ELEVATIONS NORTH- EAST
OPEN SPACE/ GRADING/ SHADING PLANS
SP-03
SP-06SP-05SP-04
SP-01SP-02
SP-07SP-08
GENERAL NOTES
FIRE DEPARTMENT NOTESGENERAL NOTES- BICYCLE PARKING NOTESGENERAL NOTES
DISABLE ACCESS NOTESDISABLE ACCESS NOTES
LOS ANGELES GREEN BUILDING NOTES AND FORMS
5254 Riverton Ave.North Hollywood, California 91601
RIVERTON APARTMENTS
10-Unit Apartments
RESIDENTIAL:TYPE V-A (4-STORY) (ZONING CODE)SUPERVISED AUTOMATIC FULLYSPRINKLERED THROUGH OUT (NFPA13)
COMMERCIAL: NONE
PARKING: TYPE IA BASEMENT (1-STORY) SPRINKLERED THROUGH OUT (NFPA13)
BUILDING HEIGHT(BUILDING CODE): 43'-6"BUILDING HEIGHT(ZONING CODE): 45'-0"
BLD'G CONST. / OCCUPANCY
VICINITY MAP
100% PRIVATELY FUNDED PROJECTNO TAX INCENTIVE CREDIT
NORTH
UNIT # QTY. BD.RM.
BATHRM. NET AREA* TOTAL NET
AREA*
101 1 2 2 1,017
* UNITS NET AREAS ARE APPROXIMATE IN SQ. FT.
102 1,054201 1,140202 1,300203 1,320204 1,054301 1,140302 1,320
TOTAL 10 11,719 12,019
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
UNIT DESCRIPTIONS
FIRE DEPARTMENT NOTES/ RECYCLING AREA NOTES
SP-09DISABLE ACCESS NOTES
303 1,320
T24-01 TITLE 24- ENERGY COMPLIANCET24-02 TITLE 24- ENERGY COMPLIANCET24-03 TITLE 24- ENERGY COMPLIANCE
1/4" SECOND FLOOR PLAN
T24-04 TITLE 24- ENERGY COMPLIANCE
GARAGE (BASEMENT) PLAN
1/4" FOURTH FLOOR PLAN
APPROVALS
VLA ENGINEERING, INC. 14416 HAMLIN ST. #204 VAN NUYS, CA 91401 818-787-3307 .
PLUMBING304 1,054
APPROVALS
1/4" FIRST FLOOR PLAN
1/4" STAIR DETAILS
A-19
MEZZ.
1 2 21 2 21 2 2.51 2 2.51 2 21 2 21 2 2.51 2 2.51 2 2 150
150
1,0171,0541,1401,3001,3201,0541,2901,3201,3201,204
CHANDLER BLVD.
MAGNOLIA BLVD.
HARM
ONY
AVE.
RIV
ERTO
N A
VE.
VIN
ELAND
AVE.
LANDSCAPE AREA PROVIDE FOR COMMON AREA:
COMMON SPACE LANDSCAPE REQUIRED (25%)=(1,250/2)*25%=
TOTAL OPEN SPACE PROVIDED:
REAR YARD WITH 15' MIN. DIM.:
RECREATION AREA=COMMON OPEN SPACE
BALCONIES WITH 6' MIN. DIM.: 50 SQ.FT.X10=PRIVATE OPEN SPACE
COURT YARD WITH 15' MIN. DIM.=COMMON SPACE
3 HABITABLE ROOM UNIT @125 SQ. FT. PER UNIT=10X125=
<3 HABITABLE ROOM UNIT @100 SQ. FT. PER UNIT=0X100=
MINIMUM COMMON OPEN SPACE REQUIRED (50%)=
OPEN SPACE PROVIDED:
0 SQ. FT.
1,340 SQ. FT.
175 SQ. FT.
156 SQ. FT.
840 SQ. FT.
0 SQ. FT.
500 SQ. FT.
0 SQ. FT.
625 SQ. FT.
1,250 SQ. FT.
TOTAL OPEN SPACE REQUIRED= 1,250 SQ. FT.
>3 HABITABLE ROOM UNIT @175 SQ. FT. PER UNIT=0X175= 0 SQ. FT.
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-01JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SITE PLANSCALE: 1/8"=1'-0"
NORTH
18RUP
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-15 AND 12/A-17
8'-2" HEADROOM CLERANCE
8" CONCRETE WALL
SECURITY CAMERA
CO
AREA DRAIN AND FLOW DIRECTION
EVS SEE NOTES
FENCE WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
SEPARATE APPLICATION AND PERMIT(S)IS/ARE REQUIRED FOR:
ELECTRICAL WORK MECHANICAL WORKPLUMBING WORK GRADINGSHORING DEMOLITIONFIRE SPRINKLER FIRE ALARMSIGNS SWIMMING POOLELEVATOR BLOCK WALLS>3'6"RETAINING WALLS
GRADE PLANE CALCULATIONS:
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)
NOTES:
59'-8
"
27'-1
0"
10'-8
"21'-2
"
PROPOSED 4-STORY TYPE VA10-UNIT RESIDENTIAL OVERONE LEVEL OFTYPE IA BASEMENT GARAGE
FIRST FLOOR FINISH=608'-0"
7'-0
"7'-0
"SID
E YA
RD
SID
E YA
RD
607.59606.73 607.33 607.38
607.78
607.31
607.07
606.82
606.85
606.86E.F.G. E.F.G.
E.F.G.E.F.G.E.F.G. E.F.G.
E.F.G.
E.F.G.
E.F.G.
E.F.G.
607.46607.91E.F.G. E.F.G.
CO
NC W
ALK
PARKW
AY
LOWEST EXISTING GRADEWITHIN 5'=607.0'
6'-8
"46'-0
"6'-8
"
10'-0
"
16'-2" 14'-912" 29'-0" 9'-10" 28'-6" 17'-0" 16'-2"
3'-0" 132'-1"15'-11
2" 101'-11" 15'-012"
FRONT YARD REAR YARDHWY.DED.
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
STAIR #2 (2/A-11) 2-HR SHAFT
STAIR #1 (2/A-11) 2-HR SHAFT
LANDSCAPE
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
T.D.607'-10"
T.W. T.W.T.W.
T.W. T.W.
T.W.
T.W.T.W.T.W.
STAIR #3 (2/A-11) 2-HR SHAFT
DRIVEWAY
T.W.
AA-10
AA-10
BA-1
0
BA-1
0
T.W.
N 88°54'18" E
N 88°54'21" E
N 01°13'26" W
N 01°13'29" W
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-02JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
GARAGE PLANSCALE: 1/8"=1'-0"
NORTH
STANDARD 5
8'-6
"8'-6
"8'-6
"8'-6
"8'-6
"
18'-0"15'-0"
STANDARD 4
STANDARD 3
STANDARD 2
STANDARD 1
8'-6
"8'-6
"8'-6
"9'-0
"9'-0
"
NO
PA
RK
ING
STANDARD 10D.A.
VAN ACCESSIBLE
STANDARD 6
STANDARD 7
STANDARD 8
10"
10"
3'-1
0"
COMPACT 1
COMPACT 2
COMPACT 3
COMPACT 4
COMPACT 5
8'-0
"
COMPACT 6
COMPACT 7
COMPACT 8
COMPACT 9
COMPACT 10
7'-6
"7'-6
"
EXIT
EXIT
2'-6
"1'-6
"2'-6
"2'-6
"2'-6
"1'-6
"1'-6
"
6'-0"
10
PER
M.
2TI
ERBIC
YCLE
PARKI
NG
1.5 HR
ELEVATOR
12
2
131'-512"
16'-2" 14'-912" 29'-0" 9'-10" 28'-6" 17'-0" 16'-2"
59'-4
"27'-6
"10'-8
"21'-2
"
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE MECHANICAL VENTILATION FOR THEGARAGE SECTION 406.4.2 (UNDER SEPARATE PERMIT)
NOTES:
OCCUPANT LOAD: TABLE 1004.1.1
7,627 SQ. FT./200=38<50 2 EXITS REQUIREDREQUIRED EXIT AND STAIR WIDTH 36" (SEC. 1009.4)EXIT ACCESS TRAVEL DISTANCE:TABLE 1016.1 S2 OCCUPANCY 400'
CAR CHARGER CALCULATIONS:TOTAL REQUIRED CARS: 20NO OF CHARGERS REQUIRED@5%= 1NO. OF CHARGERS PROVIDED" 1
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-27 AND 12/A-29
8'-2" HEADROOM CLERANCE
8" CONCRETE WALL
SECURITY CAMERA
CO
AREA DRAIN AND FLOW DIRECTION
EVS SEE NOTES
FENCE WALL
1. SEE PLANS FOR RACEWAY TERMINATION POINT (S), EVCS,AND EVE CHARGERS.2. ONLY UNDERGROUND RACEWAYS AND RELATED UNDERGROUNDEQUIPMENT ARE REQUIRED TO BE INSTALLED AT THE TIME OF CONSTRUCTION.3. THE ELECTRICAL SYSTEM SHALL HAVE SUFFICIENT CAPACITYTO SIMULTANEOUSLY CHARGE ALL DESIGNATED EV SPACESAT THE FULL RATED AMPERAGE OF EVSE. PLAN DESIGN SHALLBE BASED UPON A 40-AMPERE MINIMUM BRANCH CIRCUITS.A SEPARATE ELECTRICAL PERMIT IS REQUIRED.4. THE SERVICE PANEL OR SUB-PANEL CIRCUIT DIRECTORYSHALL IDENTIFY THE OVER-CURRENT PROTECTIVE DEVICESPACE (S) RESERVED FOR FUTURE EV CHARGING PURPOSESAS EV CAPABLE IN ACCORDANCE WITH LOS ANGELESELECTRICAL CODE.
EVS NOTES:
TRASHROOM
3
EXIT
8'-0"RAMP DN
20%RAMP DN
10%RAMP DN
10%
8'-0" 40'-0"
8'-2" MINCLEARANCE
28'-0"
STANDARD 9
ELECTRIC AUTOCHARGERSEE SP-09
A-142
CIRCULATION DRIVEWAY DETAIL
10'-0
"
12'-0"
10'-0"
12'-0
"
10'-0
"31'-7
"
31'-7"
10'-0"
20'-0
"
10'-0
"
25'-9"
ELEVATOREQUIPMENT
ROOM
REC
YCLI
NG
RO
OM
30
SF
6
596'.10"F.F.
596'.10"F.F.
596'.10"F.F.
596'.10"F.F.
596'.10"F.F.
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
T.D.596'-2"
T.D.596'-2"
T.D.596'-10"GUEST 2 BICYCLE
PARKING
IRRIGATION CONTROLSYSTEM, SOIL ORWEATHER BASE
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-03JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/4"=1'-0"
NORTH
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)
NOTES:OCCUPANT LOAD: TABLE 1004.1.1
4,514 SQ. FT./200=23<50, 2 EXITS REQUIREDREQUIRED EXIT AND STAIR WIDTH 36" (SEC. 1009.4)EXIT ACCESS TRAVEL DISTANCE: TABLE 1016.1OCCUPANCY R2: 250'
30" SINK COUNTER WITH REMOVABLEBASE CABINET AND FINISHED FLOORUNDERNEATH (TYP.) SEE 3/A-24
REMOVABLE BASE CABINET UNDERADAPTABLE LAVATORY. FINISHEDFLOOR UNDER THE CABINET AND 34"MAX. 27" MIN. CLEARANCE. SEEDETAIL 3/A-24
PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDE OF TOILET FORFUTURE GRAB BARS. SEE SHEET#SP-07 SECTION D BATHING ANDTOILET FACILITIES, WATER CLOSET #2DETAILS 8/A-24. PROVIDE TOILETFLUSH CONTROL ON THE WIDE SIDE.PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDES OF TUB/ SHOWER32" TO 38" ABOVE FLOOR FORFUTURE GRAB BARS. SEE SHEET#SP-06 SECTION D BATHING ANDTOILET FACILITIES, BATH TUBS #2DETAIL 8/A-24. PROVIDE ADDITIONALBACKING ON FLOOR FOR FUTUREPOSSIBLE FLOOR MOUNTED GRABBAR.
D
C
E
OPTION #2SEE SHT#SP-05, SP-06, SP-07 FORTYPICAL NOTES
A
SHOWER THRESHOLD MAXIMUM 2" INHEIGHT WITH BEVELED OR SLOPEDANGLE NOT EXCEEDING 1:2
F
NOTE:USE FRONT LOADED APPLIANCESOR PROVIDE ASSISTIVE DEVICE
ADAPTABLE GRAB BAR FLOOR OR SIDE
5 AIR EXCHANGE PER MINUTE MIN.EXHAUST FAN AND FLORESCENT LIGHTFANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TOTERMINATE TO THE OUTSIDE OF THEBUILDING. FANS NOT FUNCTIONING ASA COMPONENT OF A WHOLE HOUSEVENTILATION SYSTEM, MUST BECONTROLLED BY A HUMIDITYCONTROL.
HARD WIRED SMOKE DETECTORS WITHBATTERY BACK-UP AND LOW BATTERYSIGNAL DWELLING UNITS WITHIN WHICHFUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVEDCARBON MONOXIDE ALARM IN THEFOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATEDWELLING UNITSLEEPING AREA IN THE IMMEDIATEVICINITY OF BEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS
SDCO
WASHER DRYERS SHALL COMPLY WITHSECTION 1135A
18RUP
REF.
D/W
16
W/D28
18
38
2X6
M.C
.
2X6
E30"X48"
5' Ø
D
C
BATH RM #1D.A.
30"X
48"
18
M.C.
2X6
42"X
52"
18
BATH RM#2
D
C
W/D 28
38
REF.D/W
M.C
.
BATH RM#2
C
M.C
.
2X6
BATH RM#1
CD
M.C
.
2X6
BATH RM#2
C D
M.C
.
2X6
BATH RM#1
C D
LIVINGAREA
LIVINGAREA
BEDROOM #2 MASTERBEDROOM
MASTERBEDROOM
BEDROOM #2
KITCHENGRANITE TOP
KITCHENGRANITE TOP
DININGAREA
DININGAREA
SLOPE 2%
BALCONY
EXIT EXIT
10
A-152
A-152
A-152
A-153
A-152
A-153
101'-11"
18'-2" 18'-9" 6'-612" 3'-4" 6'-4" 8'-101
2" 5'-8" 8'-11" 12'-0" 9'-6"
13
'-6"
6'-0
"1
3'-3
1 2"
46
'-0"
101'-11"
11'-2"10'-4"12'-2"12'-2"12'-712"11'-81
2"12'-8"14'-3"
46
'-0"
5'-8
"4
'-5"
5'-0
"8
'-6"
7'-6
1 2"
10
'-101
2"
4'-0
"
2'-5" 2'-5"
2'-5
"1
0'-9
1 2"
6'-9
"5
'-71 2
"6
'-101
2"
6'-312" 7'-61
2" 6'-5" 6'-3" 4'-712"
5'-8
"
3'-10"3'-0" 6'-0" 6'-0" 4'-9" 1'-6"
4'-3
"
18RUP
ELEVATOR
1.5 HRDOOR
16RUP
16RUP
BEDROOM #2 BEDROOM #1 BEDROOM #2BEDROOM #1
18 1818
18
18
18
18 18
1818 18 181818
18
18
1
3'-0
"
18
18 18
18
16
30'-5"15'-5"16'-212"40'-9"
21'-6"24'-4"24'-4"31'-9"
5'-1112" 8'-31
2"3'-51
2"5'-4"
3'-1
1"
6'-1
112"
6'-8
"3
'-6"
11
'-21 2
"6'-31
2"3'-8"1'-8"3'-11"10'-3"2'-6"3'-6"
3'-11" 4'-612" 7'-71
2"
4'-0
"1
0'-2
1 2"7
"
2'-012"
3'-1
1"
11
"5
'-1"
6'-0
"4
'-6"
2'-0
"
8'-512"5'-3"
9'-4"
3'-1
1 2"
6'-312" 3'-11" 11'-31
2"
7'-1
012"
5'-5
"2
'-5"
7'-1
0"
2'-6
"1'-0
"3
'-81 2
"9
'-3"
6'-0
"
9'-3"
?
M.C
.
2X6
E30"X48"
5' Ø
D
CBATH RM #1
D.A.
30"X
48"
18M.C.
2X6
42"X
52"
18
18
BATH RM#2
D
C
2'-5" 8'-3"
7"
2'-0
"7
'-71 2
"6
'-0"
6'-0
"3
'-11
"
1'-6
"
2'-112"6'-2"4'-01
2"
A
A
A
A AA
AA
6'-5
"5
'-2"
3'-0
"6
'-9"
7'-612"5'-111
2"6'-3"4'-2"6'-5"
5'-2
1 2"
4'-3
"
6'-0"6'-0"3'-0"6'-0"21'-012"
F
8
4
UNIT101 UNIT102
E
A-172
42
" GAURD
RAIL
4'-412"
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-15 AND 12/A-17
8" CONCRETE WALL
CO
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-04JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/4"=1'-0"
NORTH
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)
NOTES:OCCUPANT LOAD: TABLE 1004.1.1
4,688 SQ. FT./200=23<50, 2 EXITS REQUIREDREQUIRED EXIT AND STAIR WIDTH 36" (SEC. 1009.4)EXIT ACCESS TRAVEL DISTANCE: TABLE 1016.1OCCUPANCY R2: 250'
REF.
D/W
16
W/D28
18
38
38
2X6
M.C
.
2X6
E30"X48"
5' Ø
D
C
BATH RM #1D.A.
30"X
48"
18
M.C.
2X6
42"X
52"
18
BATH RM#2
D
C
W/D 28
38
REF.D/W
LIVINGAREA
LIVINGAREA
BEDROOM #2 MASTERBEDROOM
MASTERBEDROOM
BEDROOM #2
KITCHENGRANITE TOP
KITCHENGRANITE TOP
DININGAREA
DININGAREA
SLOPE 2%
BALCONY
EXIT EXIT
10
SDSD
A-152
A-152
A-152
A-152
A-153
101'-11"
18'-2" 18'-9" 6'-612" 3'-4" 6'-4" 8'-101
2" 5'-8" 8'-11" 12'-4" 9'-2"
13
'-6"
6'-0
"1
3'-3
1 2"
46
'-0"
101'-11"
11'-2"10'-4"17'-5"6'-11"17'-5"12'-8"14'-3"
46
'-0"
10
'-1"
5'-0
"8
'-6"
7'-6
1 2"
14
'-101
2"
2'-5" 2'-5"
2'-5
"1
0'-9
1 2"
6'-9
"5
'-71 2
"6
'-101
2"
6'-312" 8'-61
2" 8'-1012"
6'-11"8'-101
2"
9'-8
"
3'-10"
4'-3
"
18RDN
ELEVATOR
1.5 HRDOOR
16RDN
18
18
1818
18
18
10
3'-0
"
16
30'-5"15'-5"16'-212"40'-9"
21'-6"24'-4"24'-4"31'-9"
5'-1112" 8'-31
2"3'-51
2"5'-4"
3'-1
1"
10
'-111
2"
6'-8
"3
'-6"
11
'-21 2
"
6'-312"3'-8"1'-8"3'-11"10'-3"2'-6"3'-6"
9'-4"
6'-312" 3'-11" 11'-31
2"
7'-1
012"
5'-5
"2
'-5"
7'-1
0"
2'-6
"1'-0
"3
'-81 2
"9
'-3"
6'-0
"
9'-3"
33 33
?
M.C
.
2X6
E30"X48"
5' Ø
D
CBATH RM #1
D.A.
30"X
48"
18M.C.
2X6
42"X
52"
18
18
BATH RM#2
D
C
2'-5"
2'-112"6'-2"4'-01
2"REF.
D/W
KITCHENGRANITE TOP
16
REF.
D/W
KITCHENGRANITE TOP
16
W/D28
36
SLO
PE 2
%
BALCONY
18
9'-2
"6
'-61 2
"3
'-11
"6
'-101
2"
7'-4
"4
'-2"
2'-0
"6
'-0"
W/D 28
36
SLO
PE 2
%
BALCONY
18
8'-3
"6
'-61 2
"3
'-11
"6
'-101
2"
12
'-5"
2'-0
"
18RUP
A B B
UNIT201
UNIT202
UNIT204
UNIT203
A
A
A
4
F
42
" GAURD
RAIL
D
16RDN
18RDN
42" GAURDRAIL42" GAURDRAIL
6'-5" 8'-612"
6'-5
"5
'-2"
6'-9
"
4'-9"6'-0"6'-0"3'-0"6'-0"6'-0"6'-0"3'-0"
4'-3
"5
'-21 2
"5
'-21 2
"4
'-101
2"
110'
49'-0"
49'>110'/349'>36'-6"
18RDN
42
" GAURD
RAIL
SD
SD
30" SINK COUNTER WITH REMOVABLEBASE CABINET AND FINISHED FLOORUNDERNEATH (TYP.) SEE 3/A-24
REMOVABLE BASE CABINET UNDERADAPTABLE LAVATORY. FINISHEDFLOOR UNDER THE CABINET AND 34"MAX. 27" MIN. CLEARANCE. SEEDETAIL 3/A-24
PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDE OF TOILET FORFUTURE GRAB BARS. SEE SHEET#SP-07 SECTION D BATHING ANDTOILET FACILITIES, WATER CLOSET #2DETAILS 8/A-24. PROVIDE TOILETFLUSH CONTROL ON THE WIDE SIDE.PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDES OF TUB/ SHOWER32" TO 38" ABOVE FLOOR FORFUTURE GRAB BARS. SEE SHEET#SP-06 SECTION D BATHING ANDTOILET FACILITIES, BATH TUBS #2DETAIL 8/A-24. PROVIDE ADDITIONALBACKING ON FLOOR FOR FUTUREPOSSIBLE FLOOR MOUNTED GRABBAR.
D
C
E
OPTION #2SEE SHT#SP-05, SP-06, SP-07 FORTYPICAL NOTES
A
SHOWER THRESHOLD MAXIMUM 2" INHEIGHT WITH BEVELED OR SLOPEDANGLE NOT EXCEEDING 1:2
F
NOTE:USE FRONT LOADED APPLIANCESOR PROVIDE ASSISTIVE DEVICE
ADAPTABLE GRAB BAR FLOOR OR SIDE
5 AIR EXCHANGE PER MINUTE MIN.EXHAUST FAN AND FLORESCENT LIGHTFANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TOTERMINATE TO THE OUTSIDE OF THEBUILDING. FANS NOT FUNCTIONING ASA COMPONENT OF A WHOLE HOUSEVENTILATION SYSTEM, MUST BECONTROLLED BY A HUMIDITYCONTROL.
HARD WIRED SMOKE DETECTORS WITHBATTERY BACK-UP AND LOW BATTERYSIGNAL DWELLING UNITS WITHIN WHICHFUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVEDCARBON MONOXIDE ALARM IN THEFOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATEDWELLING UNITSLEEPING AREA IN THE IMMEDIATEVICINITY OF BEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS
SDCO
WASHER DRYERS SHALL COMPLY WITHSECTION 1135A
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-15 AND 12/A-17
8" CONCRETE WALL
CO
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
2'-6"
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-05JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/4"=1'-0"
NORTH
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)
NOTES:OCCUPANT LOAD: TABLE 1004.1.1
4,688 SQ. FT./200=23<50, 2 EXITS REQUIREDREQUIRED EXIT AND STAIR WIDTH 36" (SEC. 1009.4)EXIT ACCESS TRAVEL DISTANCE: TABLE 1016.1OCCUPANCY R2: 250'
30" SINK COUNTER WITH REMOVABLEBASE CABINET AND FINISHED FLOORUNDERNEATH (TYP.) SEE 3/A-24
REMOVABLE BASE CABINET UNDERADAPTABLE LAVATORY. FINISHEDFLOOR UNDER THE CABINET AND 34"MAX. 27" MIN. CLEARANCE. SEEDETAIL 3/A-24
PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDE OF TOILET FORFUTURE GRAB BARS. SEE SHEET#SP-07 SECTION D BATHING ANDTOILET FACILITIES, WATER CLOSET #2DETAILS 8/A-24. PROVIDE TOILETFLUSH CONTROL ON THE WIDE SIDE.PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDES OF TUB/ SHOWER32" TO 38" ABOVE FLOOR FORFUTURE GRAB BARS. SEE SHEET#SP-06 SECTION D BATHING ANDTOILET FACILITIES, BATH TUBS #2DETAIL 8/A-24. PROVIDE ADDITIONALBACKING ON FLOOR FOR FUTUREPOSSIBLE FLOOR MOUNTED GRABBAR.
D
C
E
OPTION #2SEE SHT#SP-05, SP-06, SP-07 FORTYPICAL NOTES
A
SHOWER THRESHOLD MAXIMUM 2" INHEIGHT WITH BEVELED OR SLOPEDANGLE NOT EXCEEDING 1:2
F
NOTE:USE FRONT LOADED APPLIANCESOR PROVIDE ASSISTIVE DEVICE
ADAPTABLE GRAB BAR FLOOR OR SIDE
5 AIR EXCHANGE PER MINUTE MIN.EXHAUST FAN AND FLORESCENT LIGHTFANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TOTERMINATE TO THE OUTSIDE OF THEBUILDING. FANS NOT FUNCTIONING ASA COMPONENT OF A WHOLE HOUSEVENTILATION SYSTEM, MUST BECONTROLLED BY A HUMIDITYCONTROL.
HARD WIRED SMOKE DETECTORS WITHBATTERY BACK-UP AND LOW BATTERYSIGNAL DWELLING UNITS WITHIN WHICHFUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVEDCARBON MONOXIDE ALARM IN THEFOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATEDWELLING UNITSLEEPING AREA IN THE IMMEDIATEVICINITY OF BEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS
SDCO
WASHER DRYERS SHALL COMPLY WITHSECTION 1135A
REF.
D/W
16
W/D28
18
38
38
2X6
M.C
.
2X6
E30"X48"
5' Ø
D
C
BATH RM #1D.A.
30"X
48"
18
M.C.
2X6
42"X
52"
18
BATH RM#2
D
C
W/D 28
38
REF.D/W
LIVINGAREA
LIVINGAREA
BEDROOM #2MASTER
BEDROOM
MASTERBEDROOM
BEDROOM #2
KITCHENGRANITE TOP
KITCHENGRANITE TOP
DININGAREA
DININGAREA
SLOPE 2%
BALCONY
EXIT EXIT
10
SDSD
A-152
A-152
A-152
A-152
A-153
101'-11"
18'-2" 18'-9" 6'-612" 3'-4" 6'-4" 8'-101
2" 5'-8" 8'-11" 12'-4" 9'-2"
13
'-6"
6'-0
"1
3'-3
1 2"
46
'-0"
101'-11"
11'-2"10'-4"17'-5"6'-11"17'-5"12'-8"14'-3"
46
'-0"
10
'-1"
5'-0
"8
'-6"
7'-6
1 2"
14
'-101
2"
2'-5" 2'-5"
2'-5
"1
0'-9
1 2"
6'-9
"5
'-71 2
"6
'-101
2"
6'-312" 8'-61
2" 8'-1012"
6'-11"
8'-1012"
9'-8
"
3'-10"
4'-3
"
18RUP
ELEVATOR
1.5 HRDOOR
18
18
1818
18
18
1
3'-0
"
16
30'-5"15'-5"16'-212"40'-9"
21'-6"24'-4"24'-4"31'-9"
5'-1112" 8'-31
2"3'-51
2"5'-4"
3'-1
1"
10
'-111
2"
6'-8
"3
'-6"
11
'-21 2
"6'-31
2"3'-8"1'-8"3'-11"10'-3"
2'-6"3'-6"
9'-4"
6'-312" 3'-11" 11'-31
2"
7'-1
012"
5'-5
"2
'-5"
7'-1
0"
2'-6
"1'-0
"3
'-81 2
"9
'-3"
6'-0
"
9'-3"
33 33
?
M.C
.
2X6
E30"X48"
5' Ø
D
CBATH RM #1
D.A.
30"X
48"
18M.C.
2X6
42"X
52"
18
18
BATH RM#2
D
C
2'-5"
2'-112"6'-2"4'-01
2"REF.
D/W
KITCHENGRANITE TOP
16
REF.
D/W
KITCHENGRANITE TOP
16
W/D28
36
SLO
PE 2
%
BALCONY
18
9'-2
"6
'-61 2
"3
'-11
"6
'-101
2"7
'-4"
4'-2
"2
'-0"
6'-0
"
W/D 28
36
SLO
PE 2
%
BALCONY
18
8'-3
"6
'-61 2
"3
'-11
"6
'-101
2"
12
'-5"
2'-0
"
18RUP
8
4
18RDN
16RUP
A B
A
F
A
A
B42" GAURDRAIL42" GAURDRAIL
42
" GAURD
RAIL
16RUP
4'-9"6'-0"6'-0"3'-0"6'-0"6'-0"6'-0"3'-0"
UNIT301
UNIT302
UNIT304
UNIT303
D
18RDN
18RUP
18RUP
SD
SD
42
" GAURD
RAIL
SLOPE 2%
BALCONY
5'-2
1 2"4
'-101
2"
5'-2
1 2"
6'-5" 8'-612"
6'-5
"5
'-2"
6'-9
"
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-15 AND 12/A-17
8" CONCRETE WALL
CO
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
2'-6"
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-06JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/4"=1'-0"
NORTH
PROVIDE SUPERVISED AUTOMATICFIRE SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 903.3.1.1 NFPA13THROUGH OUT THE BUILDING(UNDER SEPARATE PERMIT)PROVIDE FIRE ALARM SYSTEM APPROVEDBY THE FIRE DEPARTMENT PRIOR TOINSTALLATION THROUGHOUT THE BUILDING(UNDER SEPARATE PERMIT)
NOTES:OCCUPANT LOAD: TABLE 1004.1.1
4,688 SQ. FT./200=23<50, 2 EXITS REQUIREDREQUIRED EXIT AND STAIR WIDTH 36" (SEC. 1009.4)EXIT ACCESS TRAVEL DISTANCE: TABLE 1016.1OCCUPANCY R2: 250'
30" SINK COUNTER WITH REMOVABLEBASE CABINET AND FINISHED FLOORUNDERNEATH (TYP.) SEE 3/A-24
REMOVABLE BASE CABINET UNDERADAPTABLE LAVATORY. FINISHEDFLOOR UNDER THE CABINET AND 34"MAX. 27" MIN. CLEARANCE. SEEDETAIL 3/A-24
PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDE OF TOILET FORFUTURE GRAB BARS. SEE SHEET#SP-07 SECTION D BATHING ANDTOILET FACILITIES, WATER CLOSET #2DETAILS 8/A-24. PROVIDE TOILETFLUSH CONTROL ON THE WIDE SIDE.PROVIDE 2X6 BLOCKING WITHIN WALLAT BACK AND SIDES OF TUB/ SHOWER32" TO 38" ABOVE FLOOR FORFUTURE GRAB BARS. SEE SHEET#SP-06 SECTION D BATHING ANDTOILET FACILITIES, BATH TUBS #2DETAIL 8/A-24. PROVIDE ADDITIONALBACKING ON FLOOR FOR FUTUREPOSSIBLE FLOOR MOUNTED GRABBAR.
D
C
E
OPTION #2SEE SHT#SP-05, SP-06, SP-07 FORTYPICAL NOTES
A
SHOWER THRESHOLD MAXIMUM 2" INHEIGHT WITH BEVELED OR SLOPEDANGLE NOT EXCEEDING 1:2
F
NOTE:USE FRONT LOADED APPLIANCESOR PROVIDE ASSISTIVE DEVICE
ADAPTABLE GRAB BAR FLOOR OR SIDE
5 AIR EXCHANGE PER MINUTE MIN.EXHAUST FAN AND FLORESCENT LIGHTFANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TOTERMINATE TO THE OUTSIDE OF THEBUILDING. FANS NOT FUNCTIONING ASA COMPONENT OF A WHOLE HOUSEVENTILATION SYSTEM, MUST BECONTROLLED BY A HUMIDITYCONTROL.
HARD WIRED SMOKE DETECTORS WITHBATTERY BACK-UP AND LOW BATTERYSIGNAL DWELLING UNITS WITHIN WHICHFUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVEDCARBON MONOXIDE ALARM IN THEFOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATEDWELLING UNITSLEEPING AREA IN THE IMMEDIATEVICINITY OF BEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS
SDCO
WASHER DRYERS SHALL COMPLY WITHSECTION 1135A
M.C
.
BATH RM#2
C
M.C
.
2X6
BATH RM#1
CD
M.C
.
2X6
BATH RM#2
C D
M.C
.
2X6
BATH RM#1
C D
A-152
A-153
A-153
101'-11"
18'-2" 18'-9" 6'-612" 3'-4" 6'-4" 8'-101
2" 5'-8" 8'-11" 12'-4" 9'-2"
13
'-6"
13
'-9"
46
'-0"
101'-11"
11'-2"10'-4"12'-2"12'-2"12'-712"11'-81
2"
46
'-0"
10
'-1"
5'-0
"8
'-6"
7'-6
1 2"
14
'-101
2"
18
'-9"
6'-9
"6
'-101
2"
7'-612" 6'-5" 6'-3" 4'-71
2"
9'-8
"
3'-10"
4'-3
"
ELEVATOR
BEDROOM #2 BEDROOM #1 BEDROOM #2BEDROOM #1
18 1818
18
18 18
1818 18 18
10
3'-0
"
18
18 18
18
30'-5"15'-5"16'-212"40'-9"
21'-6"24'-4"24'-4"31'-9"
3'-11" 4'-612" 7'-71
2"
14
'-21 2
"7
"
2'-012"
3'-1
1"
11
"5
'-1"
6'-0
"4
'-6"
2'-0
"
8'-512"5'-3"
3'-1
1 2"
8'-3"
7"
2'-0
"7
'-71 2
"6
'-0"
6'-0
"3
'-11
"
1'-6
"
18RUP
D
A
B
H
OPEN TO BELOW
A
B
G
G
18RDN
16RDN
MEZZ 150 SF
SD
MEZZ 150 SF
SD
16RDN
OPEN TO BELOW
OPEN TO BELOW
SDSDSDSD
5'-2
1 2"
4'-3
"5
'-21 2
"4
'-101
2"
4'-2" 6'-3" 5'-1112" 7'-61
2"
6'-1
012"
6'-9
"
18RDN 18R
DN
SLO
PE 2
%
OPEN TO BELOW
A A A
F
WATER CURTAIN INSTALLED IN ACCORDANCEWITH SEC. 903.3.1.1
EXIT SIGN W/ EMERGENCY LIGHT
HARD WIRED SMOKE DETECTORS WITH BATTERYBACK-UP AND LOW BATTERY SIGNAL DWELLING UNITSWITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED SHALL HAVE AN APPROVED CARBONMONOXIDE ALARM IN THE FOLLOWING LOCATIONS:1. OUTSIDE OF EACH SEPARATE DWELLING UNITSLEEPING AREA IN THE IMMEDIATE VICINITY OFBEDROOM(S)2. ON EVERY LEVEL OF A DWELLINGUNIT INCLUDING BASEMENTS5 AIR EXCHANGE PER MINUTE MIN. EXHAUST FAN ANDFLORESCENT LIGHT FANS SHALL BE ENERGY STARCOMPLIANT AND BE DUCTED TO TERMINATE TO THEOUTSIDE OF THE BUILDING. FANS NOT FUNCTIONINGAS A COMPONENT OF A WHOLE HOUSE VENTILATIONSYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL.
FINISHED FLOOR
8" SOLID GROUTED CONCRETE BLOCK WALL
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER
EXISTING GRADE ELEVATION
FIRE EXTINGUISHER, RECESSED INTO WALL.
00.00
A.D.
E.F.G.
F.F.
T.W. TOP OF WALL
EXISTING FINISH GRADE
AREA DRAIN
F.E.
FS
1
A WINDOW TYPE
DOOR TYPE
LEGEND:
EXIT
SD
T.D. TOP OF DRAIN
1-HR RATED WOOD FRAMING. PROVIDE X6 MIN. WOODFRAMING FOR ALL PLUMBING WALLS 11/A-26.
1
324 INTERIOR ELEVATION MARKER
14" DROP SOFFIT. VERIFY SIZE PRIOR TO CONSTRUCTIONVOID SOFFITS SHALL BE FILLED WITH INSULATION ANDSOFFITS WITH AIR-CONDITIONING DUCTS SHALL BE PRE-LIMED WITH 5/8" THICK GYP BD TAPED AND INSPECTEDPRIOR TO INSTALLATION OF THE DUCTS. AREAS REQUIRINGINSULATION ABOVE AND THE SIDE OF THE SOFFITS SHALLBE INSULATED AND INSPECTED PRIOR TO THE PRELIMDRYWALL SEE DETAIL 6&7/A-15 AND 12/A-17
8" CONCRETE WALL
CO
1-HR 50 STC WALL SEE DETAIL 2/A-15 FIRE BARRIER (PLB'S WALL)
2-HR 50 STC WALL SEE DETAIL 3/A-15 FIRE BARRIER (PLB'S WALL)
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-07JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0"
FIRST FLOOR LINE
3RD FLOOR PLATE LINE
2ND FLOOR LINE
2ND FLOOR PLATE LINE
3RD FLOOR LINE
9'-1
1 2"
9'-1
1 2"
618'-3"
608'-0"
629'-6"
GRADE PLANE 607.30'
45'-0
"
LOWEST GRADEWITHIN 5' 607.0'ZONING CODE
43'-1
01 2"
2'-6
"PARAPET LINEAVE. ROOF LINE
no parapet required persec. 705.11 exception 4
BUILDING CODE
BUIL
DIN
G H
EIG
HT
PER
BUIL
DIN
G C
OD
E<60' O
.K.
4TH FLOOR PLATE LINE
4TH FLOOR LINE
9'-1
1 2"
639'-9"
650'-0"ROOF SHEATHING LINE
1ST FLOOR PLATE LINE
9'-1
1 2"
BUIL
DIN
G H
EIG
HT
PER
ZONIN
G C
OD
E<45' O
.K.
FIRST FLOOR LINE
3RD FLOOR PLATE LINE
2ND FLOOR LINE
2ND FLOOR PLATE LINE
3RD FLOOR LINE
9'-1
1 2"
9'-1
1 2"
GRADE PLANE 607.30'
45'-0
"
LOWEST GRADEWITHIN 5' 607.0'ZONING CODE
43'-1
01 2"
2'-6
"PARAPET LINEAVE. ROOF LINE
no parapet required persec. 705.11 exception 4
BUILDING CODE
BUIL
DIN
G H
EIG
HT
PER
BUIL
DIN
G C
OD
E<60' O
.K.
4TH FLOOR PLATE LINE
4TH FLOOR LINE
9'-1
1 2"
ROOF SHEATHING LINE
1ST FLOOR PLATE LINE
9'-1
1 2"
BUIL
DIN
G H
EIG
HT
PER
ZONIN
G C
OD
E<45' O
.K.
652'-6"
EXTERIOR WALL OPENING: (SEC. 705.8.1) (1O' SIDE YARD)
GARAGE LEVEL:TOTAL EXTERIOR WALL AREA: 120'X11'3"=1,350 SQ. FT.TOTAL OPENING AREA: 48'X4'4"=208 SQ. FT.
208/1,350=15.40%<25% ALLOWED2ND THRU 4TH FLOOR LEVEL:
TOTAL EXTERIOR WALL AREA: 120'X10'3"=1,230 SQ. FT.TOTAL OPENING AREA: 2x3'x4'6"+2x8'6"x5'6"+2X8'X4'6"=196 SQ. FT.
196/1,350=14.50<25% ALLOWED
7'-6
"
6'-0
"
6'-0
"
6'-0
"
3'-0
"
618'-3"
608'-0"
629'-6"
639'-9"
650'-0"
652'-6"
06-12-2017
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-08JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0"
FIRST FLOOR LINE
3RD FLOOR PLATE LINE
2ND FLOOR LINE
2ND FLOOR PLATE LINE
3RD FLOOR LINE
9'-1
1 2"
9'-1
1 2"
GRADE PLANE 607.30'
45'-0
"
LOWEST GRADEWITHIN 5' 607.0'ZONING CODE
43'-1
01 2"
2'-6
"PARAPET LINEAVE. ROOF LINE
no parapet required persec. 705.11 exception 4
BUILDING CODE
BUIL
DIN
G H
EIG
HT
PER
BUIL
DIN
G C
OD
E<60' O
.K.
4TH FLOOR PLATE LINE
4TH FLOOR LINE
9'-1
1 2"
ROOF SHEATHING LINE
1ST FLOOR PLATE LINE
9'-1
1 2"
BUIL
DIN
G H
EIG
HT
PER
ZONIN
G C
OD
E<45' O
.K.
FIRST FLOOR LINE
3RD FLOOR PLATE LINE
2ND FLOOR LINE
2ND FLOOR PLATE LINE
3RD FLOOR LINE
9'-1
1 2"
9'-1
1 2"
GRADE PLANE 607.30'
45'-0
"
LOWEST GRADEWITHIN 5' 607.0'ZONING CODE
43'-1
01 2"
2'-6
"PARAPET LINEAVE. ROOF LINE
no parapet required persec. 705.11 exception 4
BUILDING CODE
BUIL
DIN
G H
EIG
HT
PER
BUIL
DIN
G C
OD
E<60' O
.K.
4TH FLOOR PLATE LINE
4TH FLOOR LINE
9'-1
1 2"
ROOF SHEATHING LINE
1ST FLOOR PLATE LINE
9'-1
1 2"
BUIL
DIN
G H
EIG
HT
PER
ZONIN
G C
OD
E<45' O
.K.
EXTERIOR WALL OPENING: (SEC. 705.8.1) (1O' SIDE YARD)
GARAGE LEVEL:TOTAL EXTERIOR WALL AREA: 120'X11'3"=1,350 SQ. FT.TOTAL OPENING AREA: 48'X4'4"=208 SQ. FT.
208/1,350=15.40%<25% ALLOWED2ND THRU 4TH FLOOR LEVEL:
TOTAL EXTERIOR WALL AREA: 120'X10'3"=1,230 SQ. FT.TOTAL OPENING AREA: 2x3'x4'6"+2x8'6"x5'6"+2X8'X4'6"=196 SQ. FT.
196/1,350=14.50<25% ALLOWED
EXTERIOR WALL OPENING: (SEC. 705.8.1) (1O' SIDE YARD)
GARAGE LEVEL:TOTAL EXTERIOR WALL AREA: 120'X11'3"=1,350 SQ. FT.TOTAL OPENING AREA: 48'X4'4"=208 SQ. FT.
208/1,350=15.40%<25% ALLOWED2ND THRU 4TH FLOOR LEVEL:
TOTAL EXTERIOR WALL AREA: 120'X10'3"=1,230 SQ. FT.TOTAL OPENING AREA: 2x3'x4'6"+2x8'6"x5'6"+2X8'X4'6"=196 SQ. FT.
196/1,350=14.50<25% ALLOWED
6'-0
"
6'-0
"
6'-0
"
3'-0
"
6'-1
0"
3'-0"
618'-3"
608'-0"
629'-6"
639'-9"
650'-0"
652'-6"
618'-3"
608'-0"
629'-6"
639'-9"
650'-0"
652'-6"
06-12-2017 06-12-2017
AFCO Design, Inc.10635 Santa Monica Blvd. #190Los Angeles, California 90025
Phone: 424.789.8001afcodevelopment.com
THIS DOCUMENT IS THE PROPERTY AND COPY RIGHT OFAFCO DESIGN, INC. AND SHALL NOT BE USED ON ANY OTHERWORK, BE REPRODUCED OR DISCLOSED TO OTHERS EXCEPT
BY LETTER AUTHORIZATION FROM AFCO DESIGN, INC.
SHEET NO. A-09JOB ADDRESS: 5254 RIVERTON AVE.
06-12-2017
ROOF PLANSCALE: 1/8"=1'-0"
NORTH
A/C EQUIPMENT30" HIGH
WATER HEATERPLATFORM
W/H EQUIPMENT48" HIGH
GREEN BUILDING SOLAR ROOF NOTES:
ROOF AREA: 4,300 SQ. FT.15% REQUIRED: 645 SQ. FT.AREA PROVIDED: 650 SQ. FT.
SLO
PE1/2
" PER
12"
650 SQ. FT. AREAFOR FUTURE INSTALLATION
OF SOLAR PANELS
UNDER SEPARATEPERMIT
1" CONDUIT FORFUTURE SOLAR
4'-0
"17'-0
"4'-0
"
4'-0"38'-312"4'-0"
WATER HEATERPLATFORM 8'-0"
20RDN
10'-0
"
10'-0"
10'-0
"
10'-0
"
10'-0
"
16'-0"
10