Al Azhar University – Gaza
Faculty of Engineering and Information Technology
Electrical Machines '2'
Experiment (1)
Wye & Delta conection
Name student
Zhudi Elay : 20130673
Lecture Name:
Eng.Ahmed Abed
INTRODUCTION:
3-Phase system have 3 coils and two types.
a-Delta connection.
b-Wye or "star" connection.
Look the figure >>
And this system "The balanced system" and The reason for the label because it
is 3 times single phase and every coils are later than the other 120 degree .
:OBJECTIVE
1-This was part of the plant is designed to differentiate between practical and
theoretical results prove the theory of laws.
- how to connect Delta and star with motor.
:he Experiment tools T
# Tool Function Picture 1
Ammeter
To measure
Current
2
Voltmeter
To measure
voltage
3 Tree Phase Transformer
Feed the motor by electric energy
4 Wattmeter
To measure power
watt))
9 MultiMeter Measure the terminal
voltage of generator and the field current
10 Wires Link between the
components
LAB WORK:
Details Experiment:
connection : Wye or star tFirs
The motor is connected star as in figure
The motor is connected star as in figure then connected 380V Ac is connected the motor
lines because it is required of motor is 220V and that phase voltage is equal VL/√3= 380√3=
220V, and the connect the two voltmeter to one of lines and phase in parallel to measure
the voltage value, then connect the ammeter series to measure the current value. And gave
us the following value
VL Vo IL Io P PT
378V 220 1.6A 1.6A 230W 690V
Note: The starting current in star connection=3A
Second connection: Delta
then connected 220V Ac is connected Second: Then the motor connected delta as in figure
220V, and =Vince=of motor is 220V and V phase the motor lines because it is required
then OI not equal LIin series because connect the two ammeter to one lines and phase
ave us the following connect the voltmeter in parallel to measure the voltage value. And g
value .
VL VO IL IO P PT
220V 220V 2.7A 1.6A 260W 750W
Note: The starting current in Delat connection=5A
Conclusion:
1-Some high-power drives running on Delta connection, but when you start working on the spin connection star because the intensity of the current in the delta is greater than the intensity of the current in the star If rotation began to pull the Delta High stream which may affect The motor files 2-That each connection of Delta and Star by purpose and the purpose connection is made. 3- when compared the theoretical and practical results we will see little error between
them.