rofin dc series¡logo-láser-co2-slab-alta-potencia1.pdf · slab laser control, resulting in...

1
T H E P O W E R O F L I G H T T H E P R O D U C T With a new control and user interface as well as a new control cabinet, ROFIN presents its proven CO 2 Slab Laser. The inclusion of the ROFIN Control Unit for the Slab Series means that now all products across the MACRO product range are equipped with the same control platform and comparable interface. As with the products of the FL and the DQ Series, extended monitoring and control functions are now included on the new CO 2 Slab Laser control, resulting in improved pulse-to-pulse stability, manifold control and log functions including E-Service. The new control cabinet, which can be stood against a wall, only requires access from one side and at the same time, has a smaller physical footprint. T H E P R I N C I P L E The secret for this technology are the two water- cooled electrodes (slabs). High frequency between these electrodes leads to stimulation of the laser gas. The optical resonator is formed by the front and rear mirrors and the two electrodes. The heat generated in the gas is dissipated by the water-cooled electrodes (diffusion cooling). Thus, the conventional gas circulation systems involving roots blowers or turbines are not required. The crucial advantage of this laser principle is that the laser gas neither needs to be circulated nor to be renewed permanently. That means that turbines and blowers susceptible to deterioration and service are eliminated. Thus, optics integrated into the resonator that are contaminated by flowing laser gas (especially the outcoupling windows) are a thing of the past. T H E B E N E F I T Highest electrical and optical safety levels according to EN/ISO 13849-1/2 Configurations: compact version, integration package or head/ cabinet combination New wall-mountable control cabinet with reduced footprint New control compatible for all MACRO lasers with improved pulsing capabilities, manifold control and log functions including E-Service 1 to 8 kW output power and excellent beam quality M² = 1.05 (K = 0.95) Low service requirements thanks to the robust, low-maintenance design Minimal gas consumption due to diffusion cooling Energy-saving standby operation with minimal energy consumption Spherical mirror Laser beam Spatial filter Bending mirror Electrodes (Slabs) Cylindrical mirror Diamond window Spherical mirror DCSERIES R OFIN ROFIN-SINAR Laser GmbH Berzeliusstraße 87 22113 Hamburg, Germany Tel.: +49-(0)-40-7 33 63 0 Fax: +49-(0)-40-7 33 63 4100 [email protected] www.rofin.com ROFIN-SINAR Laser GmbH • Data subject to change without notice • 03/2014

Upload: ngoduong

Post on 15-Nov-2018

228 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ROFIN DC SERIES¡logo-láser-CO2-Slab-alta-potencia1.pdf · Slab Laser control, resulting in improved pulse-to-pulse stability, manifold control and log functions including E-Service

CO2 Slab Laser with new Control and Interface.

DC SERIESROFIN

THE POWER OF L IGHT

Page 2: ROFIN DC SERIES¡logo-láser-CO2-Slab-alta-potencia1.pdf · Slab Laser control, resulting in improved pulse-to-pulse stability, manifold control and log functions including E-Service

THE POWER OF L IGHT

THE PRODUCTWith a new control and user interface as well as a new control cabinet, ROFIN presents its proven CO2 Slab Laser. The inclusion of the ROFIN Control Unit for the Slab Series means that now all products across the MACRO product range are equipped with the same control platform and comparable interface. As with the products of the FL and the DQ Series, extended monitoring and control functions are now included on the new CO2 Slab Laser control, resulting in improved pulse-to-pulse stability, manifold control and log functions including E-Service.

The new control cabinet, which can be stood against a wall, only requires access from one side and at the same time, has a smaller physical footprint.

THE PRINCIPLE

The secret for this technology are the two water-cooled electrodes (slabs). High frequency between these electrodes leads to stimulation of the laser gas. The optical resonator is formed by the front and rear mirrors and the two electrodes. The heat generated in the gas is dissipated by the water-cooled electrodes (diffusion cooling). Thus, the conventional gas circulation systems involving roots blowers or turbines are not required. The crucial advantage of this laser principle is that the laser gas neither needs to be circulated nor to be renewed permanently. That means that turbines and blowers susceptible to deterioration and service are eliminated. Thus, optics integrated into the resonator that are contaminated by flowing laser gas (especially the outcoupling windows) are a thing of the past.

THE BENEFIT Highest electrical and optical safety levels according to EN/ISO

13849-1/2

Configurations: compact version, integration package or head/cabinet combination

New wall-mountable control cabinet with reduced footprint

New control compatible for all MACRO lasers with improved pulsing capabilities, manifold control and log functions including E-Service

1 to 8 kW output power and excellent beam quality M² = 1.05 (K = 0.95)

Low service requirements thanks to the robust, low-maintenance design

Minimal gas consumption due to diffusion cooling

Energy-saving standby operation with minimal energy consumption

Spherical mirrorLaser beam Spatial filter Bending mirror

Electrodes (Slabs)Cylindrical mirror Diamond window Spherical mirror

DC SERIESROFIN

ROFIN-SINAR Laser GmbHBerzeliusstraße 8722113 Hamburg, GermanyTel.: +49-(0)-40-7 33 63 0 Fax: +49-(0)-40-7 33 63 4100