room air conditioner & heat pump use and care manual · a nameplate visible after the front of...
TRANSCRIPT
is a registered trademark of Maytag Corporation or its related companies
and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
Room Air Conditioner & Heat PumpUse and Care Manual
IntroductionRoom air conditioners cool, dehumidify, and filter air insideyour home. Heat pump and electric heat models offer bothheating and cooling. Opening sections of manual providegeneral information for all room air conditioner models.Operating Controls section describes operation of controlsfor each model. After reading the opening sections, turn toOperating Controls section and find the panel layout thatmatches the model of your unit.Read entire manual thoroughly before beginning installationand operation of your new room air conditioner. Be sure youhave all necessary tools and materials on hand for the job.Study illustrations to familiarize yourself with importantdetails of the installation process. Review manual for oper-ating instructions.
NOTE1. Mechanical experience is required to install air condi-
tioner.2. Installation can take from 1 to 3 hours, depending on
installer’s knowledge and skill.3. If you encounter problems during installation, call our
consumer information line toll-free at 1-877-376-0214. Ifyour problem cannot be resolved by phone, contact anauthorized Amana® brand servicer. Contact and servicewill be at your expense.
IO-372A©2010 Goodman Company, L.P.Effective: May 2010
Safety InformationBe sure electrical service is adequate for chosen model of airconditioner. Complete electrical rating for unit is found onserial plate located behind front grille. Electrical outlet mustbe close enough to unit for power cord to reach without strain.Air conditioner should be the only appliance on individualcircuit.For personal safety and to avoid possible damage to appli-ance or home, observe all safety instructions highlighted bysymbol shown below.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.After installing unit, reread instructions to ensure each stepis complete and that all parts are fastened in place. For bestresults and to minimize installation time, perform all proce-dures in the order shown.
WARNING
Contents
Introduction .................................................................. 1
Safety Information ....................................................... 1
Unpacking .................................................................... 2
Electrical Requirements .............................................. 2
Installation ................................................................... 3
Room Heat Pumps ....................................................... 3
Normal Care & Maintenance ...................................... 3
General Instructions .................................................... 5
Installation Instructions ............................................... 6
Through-The-Wall Installation Instructions ............. 12
Operating Controls .................................................... 15
Before Calling Service .............................................. 17
When Service Is Required ........................................ 18
Any Questions? .......................................................... 18
Warranty ..................................................................... 20
2
WARNING
WARNING
HIGH TEMPERATURE STRESS HAZARDThis room air conditioner is not meant to provideunattended cooling or life support for persons oranimals that are unable to react to failure of theproduct.
The failure of an unattended air conditioner mayresult in extreme heat in the conditioned spacecausing overheating or death or persons oranimals.
Precautions must be taken to ward off or guardagainst such an occurrence.
WARNING
UnpackingUnpack and visually inspect the unit. Report any damage tothe delivering carrier immediately. Remove and discard allpacking material.
Do NOT operate unit with shipping foamblocks in place. Always remove prior torunning unit.
WARNING
On some models the air conditioner front and/or mounting kithardware may be packed separately.Record the model, serial and manufacturing numbers of yourunit in the space provided below. This information is found ona nameplate visible after the front of the air conditioner hasbeen removed. The rated voltage, amperage and capacity foryour specific model can also be found on this nameplate.Read the warranty packaged with the unit. Keep the warrantyand a copy of your sales receipt for future reference. You mayalso want to record in the space provided the date purchasedand the selling dealer.
OWNER'S PRODUCT IDENTIFICATION
MODEL NUMBER
SERIAL NUMBER
MANUFACTURING NUMBER
Owner's Name
Address
City State Zip
/ / Date of Purchase
Authorized Dealer
Address
City State Zip
( )Phone Number
To avoid death, personal injury or propertydamage due to electrical shock:• Observe all local codes and ordinances.• Disconnect electrical power to unit before servicing.• Ground appliance properly.• Check with a qualified electrician if you are not sure this appliance is properly grounded.• DO NOT ground to gas line.• DO NOT ground to cold water pipe if pipe is interrupted by plastic, non-metallic gaskets, or other insulating (non-conducting) materials.• DO NOT modify plug on power cord. If plug does not fit electrical outlet, have proper outlet installed by qualified electrician.• DO NOT have a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit could result in an electrical shock.• DO NOT use an extension cord with this appliance.• DO NOT use an adapter plug with this appliance.• DO NOT pinch power cord.• DO NOT REMOVE warning tag from power cord.
WARNING
Electrical RequirementsGrounding InstructionsThis appliance is equipped with a three-prong grounding plugfor protection against possible shock hazards. If a two-prong
3
wall receptacle is encountered, the customer is required tocontact a qualified electrician and have the two-prong wallreceptacle replaced with a properly grounded three-prongwall receptacle in accordance with the National ElectricalCode.Room air conditioners are designed to operate according torequirements on the nameplate and as shown in Table 1.Fuse or circuit breaker ratings must be according to the fuseinstruction label and as shown in Table 1. Do not plug modelsmarked “Use on Single Outlet Circuit Only” into a circuit withanother appliance or light fixture.
Receptacle WiringReceptacle wiring must be of adequate size for unit. Referto unit identification plate for exact power requirements.Minimum size of wiring, based on power requirements, is:Units up to 20 amps: 12 gauge20–30 amp units: 10 gauge
Use copper wire only. Consumer’s responsibility is to provideproper and adequate receptacle wiring that conforms to allapplicable codes. All wiring should be installed by qualifiedelectrician.
LCDI or AFCI Power CordsUnderwriters Laboratories (UL) and the National ElectricCode (NEC) now require power cords that sense currentleakage and can open the electrical circuit to the unit. In theevent, the unit does not operate, check the reset buttonlocated on or near the head of the power cord as part of thenormal troubleshooting procedure.
InstallationComplete step-by-step installation instructions are furnishedwith your unit. These instructions will be found on a separatepage included with this manual or in the mounting kitassembly. Follow these instructions carefully. Keep theseinstructions with this manual for future reference. Your unitwill be one of the following designs:
• Unit with a window mounting kitThese models are designed for mounting though anopening in a wall. These units can be adapted towindow installation by using the optional window mount-ing kit supplied with your unit.
• Unit without a window mounting kitNo window mounting kit is supplied with the unit.These models are designed for mounting through anopening in a wall. These units can be adapted towindow installation by purchasing an optional windowmounting kit. Consult your dealer to choose the kit thatis appropriate for your model and installation.
Room Heat PumpsHeat pumps work by moving heat instead of creating it. In thesummer, the cool indoor coil absorbs heat from your roomand moves it outdoors, providing cooling. In the winter, heatpumps reverse this operation. By lowering the temperatureof the outdoor coil below the outdoor temperature, the heatpump absorbs the heat from outdoors and moves it insideyour house. This heat transferring process is very efficient.For example, at 45°F outdoor temperature, a heat pump canprovide 2 ½ watts of heat for every watt of electricity itconsumes.As outdoor temperatures drop, the heating capacity andefficiency of the heat pump declines. At temperatures below45°F, it is likely that ice will form on the outdoor coil. Heatpump units are designed to operate as a heat pump aboveapproximately 40°F. Below 40°F, these units switch auto-matically from reverse cycle heat pump to auxiliary electricheating. No defrost is required. There is no minimumoperating temperature.
Normal Care and MaintenanceWARNING
Installing an air conditioner through a wall requiresextensive carpentry and/or masonry experience.Thru-wall installations performed by inexperiencedor unqualified individuals can result in costlydamage to home or result in equipment malfunctionthat could cause property damage, personal injuryor death.
CAUTION
NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115V
NEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V ratedat 12 amperes orless
NEMA No. 6-20P NEMA No. 6-20R 250V-20AMP 230/208V ratedover 12 amperes,but not more than16 amperes
NEMA No. 6-30P NEMA No. 6-30R 250V-30AMP 208V rated over16 amperes, butnot more than24 amperes
Unit Plug Receptacle Circuit Rating, VoltageType Required Breaker, Time Rating On
Delay Fuse Nameplate
4
Annual InspectionIt is suggested that your unit be inspected by your dealer orservicer once a year. It is advisable to have the outer caseremoved and the unit thoroughly cleaned.
Note: The life of your unit may be greatly reduced if you livein a salt air or other corrosive type environment. Under theseconditions, the unit should be removed from its case andcompletely cleaned at least once a year. At that time anyscratches or blisters on the painted surfaces should besanded and repainted. Placing an algaecide tablet in theoutdoor side of the unit’s basepan is suggested in humidareas where algae formation is common. We recommend thefollowing algaecide cleaners: PanGuard® by Control ReleasedTechnologies, Inc. and CDC Anti-Clog® by Virginia KMP.
Front Grille and Filter RemovalThe front contains an air filter that can be removed. To cleanthe filter, use the following method for filter removal.
Grasp exhaust grille and hinge up.
Grasp filter handle and slide filter out of unit.
Optional Charcoal Air Filter InstallationRemove charcoal air filter from plastic bag. Insert three tabson right side of filter into three slots on filter frame. Carefullybow middle of filter until two tabs on filter can be inserted intotwo slots on filter frame. Relax bow.
Reinstall air filter by reversing removal procedure.
Front Grille and Cabinet CleaningGrille and cabinet may be cleaned with warm water and mildsoap or detergent. Cleaning and polishing compounds are notrecommended, as they may damage plastic surfaces.
Air Filter CleaningA dirty air filter reduces operating efficiency of unit. Filtershould be inspected at least once every week during opera-tion. Clean filter with vacuum cleaner or wash in warm waterand mild detergent. Filter should be thoroughly dried beforereplacing in unit. Do not operate unit without filter in place.
Fan Motor CareThe fan motor is permanently lubricated for long life. There isno need to oil the motor.
Slide-out Chassis Removal from Outer Case
1. Hinge front grille up.2. Remove air filter by grasping handle and lifting up.3. Remove 3 screws (1 each side and 1 behind filter) holding
plastic front to unit and remove front.4. If the unit has a screw holding the basepan clip to the
chassis, remove the screw.
CAUTIONTo reduce the risk of personal injury, be sure tohave sufficient help when moving your unit. Aroom air conditioner can weigh between 70 and240 pounds.
5. Using basepan handle, pull chassis straight out, slowlyand evenly, until approximately 9-12 inches extends fromouter case. Use both hands to grasp basepan and pullremaining chassis from outer case.
NOTE: Basepan clip is shipped in plastic bag with mountingscrew and condensate drain cup. Install clip after reinsertingchassis into outer case to prevent accidental chassis re-moval.
5
Plastic Front
Chassis
General Operating InstructionsWhile operation of all units is similar, controls vary slightlyfrom model to model. Operating Controls section showscontrol panel of unit purchased and gives detailed informationabout operation of controls.
Initial Start-Up and CoolingSelect the highest fan speed and set temperature control toits coldest position. When the desired temperature isreached, slowly move the temperature control toward awarmer setting until the compressor shuts off. The thermo-stat will then cycle the compressor on and off to maintain thisselected temperature. Adjust the fan speed for desired aircirculation.
OutdoorLouversIndoor
Grille
Baffles
Changing Airflow Direction BafflesAirflow on unit may be diverted left or right from center bybaffles. Upward and downward air discharge is provided bytilting louvers. Adjust baffles and tilt louvers for desiredairflow pattern. Unit also has automatic left to right airmovement with "Circulaire" feature. (See page 15 underOperating Controls.)
Airflow Around UnitCheck the indoor grille and outdoor louvers for obstructions toairflow. Do not block the airflow to and from the unit. If air isobstructed and/or deflected back into the unit, the airconditioner’s compressor may cycle on and off rapidly. Thiscould damage your unit.
Drain Cup Installation and UseYour air conditioner uses a system where the water removedfrom the indoor air (condensate) is channeled to the outdoorside of the unit. The outdoor fan blade has a “slinger” ringattached to it that dips into the water and slings the water ontothe outdoor coil surface. This is the sound of water you hearduring normal operation. The water quickly evaporates on thiswarm surface and improves the efficiency of your air conditioner.In normal conditions the unit can evaporate the water as fastas it is removed from the indoor air.However, in very humid conditions excess amounts of watermay drip off the unit chassis. If this proves to be a problem,install the condensate drain cup included with the unit to routeexcess water where it would not be a problem (see illustrationbelow).To install, remove the unit chassis from the outer case. Insertthe condensate drain cup through the recessed ½” hole on theback center flange of the outer case. Once inserted, place a½” diameter hose or tube on the drain cup bottom spout. Thehose allows you to route where you want the excess water togo. Reinsert the unit chassis into the outer case. The unitbasepan overflow hole will be positioned directly above thedrain cup and will catch any water that might run out.
1/2" DiameterHose
CondensateDrain Cup
Outer Case
Switchover Thermostat ControlEmergency heat switch overrides heat pump (compressor)and starts auxiliary electrical heater. When switch is ON,heat pump is locked out.
• Use emergency switch only when heat pump fails toprovide adequate heat. Cause of heat pump malfunc-tion should be determined by authorized servicer. Costof operating unit will increase when emergency heatswitch is engaged.
6
InstallationInstructions
Air Conditioner
BEFORE YOU BEGIN
Read these instructions completely and care-fully.• IMPORTANT - Save these instructions for local
inspector's use.
• IMPORTANT - Observe all governing codes andordinances.
• Note to Installer - Be sure to leave these instructionswith the Consumer.
• Not to Consumer - Keep these instructions for futurereference.
• Skill level - Installation of this appliance requires basicmechanical skills.
• Completion time - Approximately 1 hour
• We recommend that two people install this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is notcovered under the Warranty.
Question? Consumer information line toll-free 1-877-376-0214
ELECTRICAL REQUIREMENTS
The 3-prong grounding plug minimizes thepossibility of electric shock hazard. If the walloutlet you plan to use is only a 2-prong outlet, it isyour responsibility to have it replaced with aproperly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c.protected with a time delay fuse or circuitbreaker. These models should be installed ontheir own single branch circuit for bestperformance and to prevent overloadinghouse or apartment wiring circuits, whichcould cause a possible fire hazard fromoverheating wires.
CAUTIONDo not, under any circumstances, cut orremove the third (ground) prong from thepower cord.Do not change the plug on the power cord ofthis air conditioner.Aluminum house wiring may present specialproblems - consult a qualified electrician.
Power cord includes a current interrupter device.A test and reset button is provided on the plugcase. The device should be tested on a periodicbasis by first pressing the TEST button and thenthe RESET button. If the TEST button does not tripor if the RESET button will not stay engaged,discontinue use of the air conditioner and contact aqualified service technician.
Adjustable wrenchAdjustable wrench
WARNINGDisconnect ALL power to unit before installing or servicing, makingsure unit is plugged in only when instructions state it is safe to do so.Failure to follow instructions may cause property damage, personalinjury or death.
Phillips head screwdriver
Level
Phillips head screwdriver
Pencil
Flat-blade screwdriver
Ruler or tape measure
Scissors or knife
TOOLS YOU WILL NEED
7
Type A (6)
V-support (2)
Window locking
bracket (2)
Topmounting
rail
Rightaccordion
panel
Foam topwindow gasket
Windowsash seal
Leftaccordion
panel
Type B (4) Type C (7) Type E (
Bolt (2) & nuts (2)
PARTS INCLUDED(Appearance may vary)
Installation Instructions
Type D (6) Type E (4) Type F (2)
Installation Instructions
8
1/2" higherthan frame
Stormwindowframe
Wood
Stool
• These instructions are for a standard double-hung window. You will need to modify them forother types of windows.
• The air conditioner can be installed without theaccordion panels if needed to fit in a narrowwindow. See the window opening dimensions.
• All supporting parts must be secured to firmwood, masonry or metal.
• The electrical outlet must be within reach of thepower cord.
1 WINDOW REQUIREMENTS
• A storm window frame will not allow the airconditioner to tilt toward the outside, and willkeep it from draining properly.To adjust for this, attach a piece of wood tothe stool.
WOOD PIECESWIDTH: 2"LENGTH: Long enough to fit inside the windowframe.THICKNESS : To determine the thickness, place apiece of wood on the stool to make it 1/2" higherthan the top of the storm window frame.Attach securely with nails or screwsprovided by the installer.
2 STORM WINDOW REQUIREMENTS
Remove the locking screw and lockingbracket from the lower frame. Save toreinstall later.
Remove the ground screw and save toreinstall later.
4 PREPARE THE WINDOW
3 REMOVE THE AIR CONDITIONERFROM THE CASE
A
B
Cut the window sash seal to the properlength. Peel off the backing and attach theseal to the underside of the window sash.
Installation Instructions
C Slide the air conditioner from the case bygripping the base pan handle and pullingforward while bracing the case.
Remove the ground screw and save to reinstall later.
Remove shipping screws(if present) and discard
Installation Instructions
9
PREPARE THE CASE
Install the top mounting rail with 4 type Bscrews from the inside of the case.
Insert the frames for the accordion panelsinto the top mounting rail and the bottomframe guides. Attach the accordion panels to the side of the case using 3 type A screwson each side.
Note: When attaching the accordion panels,make sure to only screw the inner panels to the case sides.
B
A
5
Installation Instructions
Top mounting rail
Bottom frame guides
INSTALL THE CASEIN THE WINDOW
Carefully slide the case into the window andcenter the case. Lower the window behindthe top mounting rail. Pull the bottom of thecase forward so that the bottom mountingrail is tight against the back of the windowstool. Mount the case to the window sill using4 type E screws. Drill pilot holes, if necessary.
Make sure the bolts and nuts are all of the way in both the left and right V-supports.
Position the V-supports on the case bottomso that they will be near the outside wall.Attach a V-support to each side of thebottom of the case using type C screws, 3 on each side.
C
B
A
6
Bolt and nut
V-support
4 type E screws
S tool
Make sure the bolts and nuts are all of theway in both the left and right V-supports.
Stool
Installation Instructions
Position the V-supports on the case bottomso that they will be near the outside wall.Attach a V-support to each side of thebottom of the case using type C screws,3 on each side.
Carefully slide the case into the window andcenter the case. Lower the window behindthe top mounting rail. Pull the bottom of thecase forward so that the bottom mountingrail is tight against the back of the windowstool. Mount the case to the window sill using4 type E screws. Drill pilot holes, if necessary.
10
Ins tallation Ins tructions
INSTALL THE CASEIN THE WINDOW (cont.)Adjust the leveling bolts and nuts against theoutside wall so that the case has a slight tiltto the outside. Tighten nuts with an adjustablewrench. Use a level; about a 1/2 bubble willbe the correct case slant to the outside.
Use a wood block (obtained locally) betweenthe leveling bolts and the wall if the wall isweak or if the weight of the air conditionerfalls between the studs in the wall.
Extend the left and right accordion panels to the vertical window sashes. Drill pilotholes and attach the top and bottom cornerswith 4 type D screws.
F
E
D
6
Type D screw Type D
screw
Type Dscrew
Top mounting rail
Type Dscrew
INSTALL SUPPORT BRACKETSAND THE FOAM TOP WINDOWGAS KETAttach the support brackets with two type D screws, one on each s ide.
Cut the foam top window gasket to thewindow width.
Stuff the foam between the glass and thewindow to prevent air and insects fromgetting into the room.
C
B
A
7
Adjust the leveling bolts and nuts against theoutside wall so that the case has a slight tiltto the outside. Tighten nuts with an adjustablewrench. Use a level; about a 1/2 bubble willbe the correct case slant to the outside.
Installation Instructions
11
INS TALL THE AIR CONDITIONERIN THE CASESlide the airconditioner into the case. Do notpush on thecontrols or thefinned coils. Make sure the air conditioner is firmly seated.
Reinstall the locking bracket and screwremoved earlier.
Reconnect the ground wire to the airconditioner using the screw removed earlier.IMPOR TANT: The ground wire must bereinstalled to ensure a proper ground.
Remove the front grille from its box andremove the shipping tape.
Grasp the inlet grille at the bottom cornersand pull it forward. Unhook it from its tophinges and set it aside.
Using the tab, pull up slightly on the filter to release it and pull it down and out.
F
E
D
C
B
A
8
Ins tallatio n Instructio ns
INSTALL THE AIR CONDITIONERIN THE CASE (cont.)
Pull the coiled power cord from its shippedposition in the air discharge area. Attachthe front grille frame to the case by insertingthe tabs on the grille frame into the slots on the front top of the case. Push the grilleframe in. And install the 2 side screws at bottomleft and right side of front panel.
Secure the front grille frame to the casewith one type C screw.
Reinstall the filter.
Reinstall the inlet grille. Connect power.J
I
H
G
8
Guide the lever carefullythrough the grille frame as you push it in.
Remove the front grille from its box andremove the shipping tape.
Slide the airconditioner intothe case. Do notpush on thecontrols or thefinned coils.Make sure theair conditioneris firmly seated.
Installation Instructions
Pull the coiled power cord from its shippedposition in the air discharge area. Attach thefront grille frame to the case by inserting the tabson the grille frame into the slots on the front topof the case. Push the grille frame in. Install the2 Type F screws at the bottom left and right sidesof the front panel.
12
Dimension of Bottom Rail
/2"
3”
Front ofouter case
Bottom rail
26”
9”
16 7/8”
AE18: 25 3/5”18: 28 1/3”AH
Outer Case Dimensions(chassis removed)
General InstructionsAll Amana® brand Compact Room Air Conditioners featurea slide-out chassis. Chassis and front cover must be re-moved from outer case for installation.
IntroductionThis instruction sheet provides guidelines for installing acompact air conditioner through an outside wall.
WARNING
Installing an air conditioner through a wall requiresextensive carpentry and/or masonry experience.Thru-wall installations performed by inexperiencedor unqualified individuals can result in costlydamage to home or result in equipment malfunctionthat could cause property damage, personal injuryor death.
CAUTION
Air Conditioner DimensionsThe following figures show the outside dimensions of airconditioner with chassis installed, and dimensions of outercase with chassis removed.
Thru-wall Installation Instructionsfor Amana® Brand Room Air Conditioner
is a registered trademark of Maytag Corporation or its relatedcompanies and is used under license to
Goodman Company, L.P., Houston, TX. All rights reserved.
Air Conditioner Dimensions(with chassis installed)
13
In order to reinstall the chassis and re-attach the air conditioner front cover, theinstalled outercase must be square and level from side to side. Use wood shimsbetween sides of case and finished open-ing - especially where case is secured toopening - to prevent warping or distorting.Check installed case for distortion usingcarpenter's square.
CAUTION
A finished opening 26 1/8-inches wide x 17-inches high isrecommended. The lower left inside corner of opening mustbe within 5 feet of an appropriate electrical outlet (see Useand Care manual for electrical requirements.)When wall thickness exceeds 9-inches, opening must bemodified to allow air to enter side louvers on case (see spe-cial instructions on back ). Do not install air conditioner inwalls thicker than 11 2/5-inches.
Brick Veneer or Frame Wall ConstructionSee CAUTION under General Instructions. Cut or buildrough opening large enough to allow a framed, finishedopening 17-inches high and 26 1/8-inches wide. When caseis properly positioned in opening, secure it to framing mate-rial with nails or screws driven through holes in sides ofouter case (shim case and predrill holes before securing).
Framinglumber
26 1/8”
17”
Framed/Finished Opening(brick veneer or frame wall construction)
Placement of Outer Case in OpeningPlace outer case in opening, flush against one side ofopening. Use carpenter’s level and ensure case is levelfrom side to side and has a 3/8-inch slope from front to back(back of case must be 3/8-inch lower than front to ensureproper condensate drainage). If needed, use shims to levelcase (from side to side) and to obtain proper back slope.Front of case must project ¾-inch (minimum) beyond in-side wall in order to attach air conditioner front frame. Ifframing indoor side of opening with wood molding (or otherdecorative material), extend outer case ¾-inch beyondmolding.When case is properly positioned in opening, use woodshims to fill any gaps between case and finished opening,especially in area where case will be secured to opening.Take care not to warp or distort case when installingshims. For condensate drainage, install drainage cup indrain hole on baseplate of case.
Dimensions of Finished Opening
Masonry ConstructionSee CAUTION under General Instructions. In masonrywalls, cut or build a finished opening 17-inches high by26 1/8-inches wide. When case is properly positioned inopening, secure it in place with mortar or concrete nailsdriven through holes in sides of outer case (shim case andpredrill holes before securing with nails).
14
Caulk allsides
Lintel andflashing(if required)
Outercase must projecta minimum ¾" beyond inside wallor molding to attach front frame
93/8"
with 3/8"
drainage
Front of outer caseto side air louvers
Optionalmolding (not provided)
Installed Case(brick veneer or frame wall construction shown)
Installation in WallThicker Than 9-inchesThe side louvers in outer case provide ventilation to air con-ditioner compressor and fan motor and must not beblocked. When installing unit in a wall over 9-inches thick,provisions must be made in wall opening to ensure free airflow to the side louvers. This can be accomplished bychamfering the vertical portions of the outside opening asshown.Ventilation louvers on top of case must not be obstructed.Do not attempt to install unit in walls thicker than11 2/5-inches.
5
Chamfering Walls Thicker Than 9-inches
15
Operating ControlsOperating your air conditioner properly helps you to obtain thebest possible results.This section explains proper air conditioner operation.IMPORTANT:
• If you turn off the air conditioner, wait at least 3 minutesbefore turning it back on. This prevents the air condi-tioner from blowing a fuse or tripping a circuit breaker.
• Do not try to operate your air conditioner in the coolingmode when outside temperature is below 61°F (16°C).Do not try to operate your air conditioner in the heatingmode when outside temperature is over 86°F (30°C).
NOTES:1. NOTE: Factory default setting is for °F. To convert to
°C, press the INCREASE / DECREASE buttonssimultaneously for approximately 5 seconds. To returnto °F, repeat the procedure.
2. In the event of a power failure, your air conditioner willoperate at the previous settings when the power isrestored.
Lights next to the touch pads on the air conditioner controlpanel indicate the selected settings.
ControlsPower Pad (Button)Turns air conditioner on and off. When turned on, thedisplay will show the room temperature.
DisplayShows the Set temperature when in HEAT, COOL orENERGY SAVER mode; shows the time remaining onthe Delay Timer; shows the room temperature when inFan Only mode. The SET light will turn on while setting.
Temp Increase / Decrease Pads
Use to set temperature when in HEAT (on some mod-els), COOL or ENERGY SAVER mode. The SET lightwill turn on while setting.
Delay Timer Increase (+) / Decrease (-) Pads
Each touch of the INCREASE / DECREASE padson the unit or the INCREASE (+) / DECREASE (-) padson the remote control will set the delay time when usingthe TIMER 0.5-24 hr. The SET light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to LOW, MED, HIGH or AUTO,on the unit.NOTE: On the remote control, use the fan speed IN-CREASE (+) / DECREASE (-) pads to set the fan speedsto LOW, MED or HIGH. Use the AUTO pad to turn Autofan on.
Mode Pad
Use to set the air conditioner to COOL, ENERGY SAVER,FAN ONLY or HEAT (on some models) mode.
Timer Pads
TIMER ON - When the air conditioner is off, it can be setto automatically come on in 0.5 (1/2 hr.) to 24 hours atits previous mode and fan settings.TIMER OFF - When the air conditioner is on, it can beset to automatically turn off in 0.5 (1/2 hr.) to 24 hours.
control panel indicate the selected settings.
Set
TIMERSWING
-
FANSPEED
MED
HIGH
LOW
AUTO
POWER
COOL
FAN ONLY
HEAT
MODE 0.5-24 HR
ENERGY SAVER
TEMP/TIMER
+
Light indicates thedelay timer is set.
Light indicates the unitis in the temperature ordelay time Set mode.The display always shows the room
temperature except when setting theSet temperature or the Delay timer.
Air Conditioner Controls
Light indicatesSWING is on.
Light indicates
SWING is on.
The display always shows the room
temperature except when setting the
Set temperature or the Delay timer.
Light indicates the unit is in the temperature or
delay time Set mode.
7
4 Delay timerDecrease
5 Mode select6
5 Fan speedDecrease
5
5 Temperatureset Increaseand Decrease
3
The display shows the Set temperaturewhen in HEAT, COOL or ENERGY SAVERmode. It also shows the time remaining onthe Delay timer and the room temperaturewhen in Fan Only mode.
TIMER 0.5-24 hr
TIMER
16
How to set:Press the TIMER 0.5-24 hr pad on the unit or theTIMER padon the remote control. Each touch of the INCREASE / DECREASE pads on the unit or the INCREASE (+) /DECREASE (-) pads on the remote control will set thetimer in 0.5 (1/2 hr.) or 1-hour intervals. (The delay timercan be set in 0.5 (1/2 hr.) increments if programmed forunder 10 hours, but if the delay timer is set for above 10hours, the timer will be set in 1-hour increments.) TheSET light will turn on while setting.To review the remaining time ,press the TIMER 0.5-24 hr pad on the unit or the TIMER padon the remote control. Use the INCREASE / DE-CREASE pads on the unit or the INCREASE (+) /DECREASE (-) pads on the remote control to set a newtime if desired.To cancel the timer, press and hold the TIMER 0.5-24 hrpad until the light on the TIMER 0.5-24 hr pad goes off.
Swing Pad
Turn on to provide continuous side-to-side air circulation.For fixed side-to-side air direction, turn on until the de-sired air direction is obtained, then turn it off.
Remote Control:• To ensure proper operation, aim the remote control at
the signal receiver on the air conditioner.• The remote control signal has a range of up to 20 feet.• Make sure nothing is between the air conditioner and
the remote control that could block the signal.• Make sure your batteries are fresh and installed cor-
rectly as indicated on the remote control.
Cool ModeUse the COOL mode at LOW, MED, HIGH, or AUTOFAN SPEED for cooling. Use the TEMPERATURE IN-CREASE / DECREASE pads to set the desiredtemperature between 61° and 86°F in 1° increments.The compressor will cycle on and off to keep the room atthe set level of comfort. Set the thermostat at a lowernumber and the indoor air will become cooler. Set thethermostat at a higher number and the indoor air will be-come warmer.NOTE: If the air conditioner is off and then turned onwhile set to a COOL setting, or if it is turned from a fansetting to a COOL setting, it may take approximately 3minutes for the compressor to start and cooling to begin.
Cooling DescriptionsFor Normal Cooling - Select the COOL mode and HIGHor MED fan with a middle set temperature.For Maximum Cooling - Select the COOL mode andHIGH fan with a lower set temperature.For Quieter & Nighttime Cooling - Select the COOLmode and LOW fan with a middle set temperature.
Energy Saver ModeControls the fan.ON - The fan will cycle on and off with the compressor.This results in wider variations of room temperatureand humidity and is normally used when the room isunoccupied.NOTE: The fan may continue to run for a short time afterthe compressor cycles off.
OFF - The fan runs all the time, while the compressorcycles on and off.
Fan Only ModeUse the FAN ONLY mode at LOW, MED or HIGH fanspeed to provide air circulation and filtering without cool-ing. Since the fan only settings do not provide cooling, aSET temperature cannot be entered. The room tempera-ture will appear in the display.NOTE: Auto Fan Speed cannot be used when in the FANONLY mode.
Heat Mode (on some models)Use the HEAT mode at LOW, MED, HIGH or AUTO FANSPEED for heating. Use the TEMPERATURE INCREASE
/ DECREASE pads to set the desired tempera-ture between 61°F and 86°F in 1°F increments.
Auto Fan SpeedSet to AUTO fan speed for the fan speed to automati-cally set to the speed needed to provide optimum com-fort settings with the set temperature. If the room needsmore cooling, the fan speed will automatically increase.If the room needs less cooling, the fan speed will auto-matically decrease.NOTE: Auto Fan Speed cannot be used when in the FANONLY mode.
Power Outage Recovery FeatureIn the case of a power outage or interruption, the unit willautomatically re-start in the settings last used, after thepower is restored. If the TIMER 0.5-24 hr feature was set,it will resume countdown. You may need to set a newtime if desired.
17
BEFORE CALLING SERVICE
PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY
UNIT WILL NOT RUN No power to unit Push reset button on power cord.
Set Fan Control to position other than OFF.
Make sure plug is firmly seated in outlet.
Check for blown fuses, tripped circuit breakers.
LITTLE OR NO COOLING
LITTLE OR NO HEATING (fan and compressor run)
Fresh air/exhaust damper open
Obstructed indoor or outdoor airflow
Dirty air filters
Unit undersized for application
Set vent to CLOSED.
Remove obstruction from indoor grille or outdoor louvers.
Dirty air filter. Clean or replace, as needed.
Check with dealer to determine proper capacity unit for application.
LITTLE OR NO COOLING
LITTLE OR NO HEATING (only fan runs)
Temperature Control not set properly For cooling, turn Temperature Control to cooler setting.
For heating, turn Temperature Control to warmer setting.
NOISY UNIT Loose front on mounting assembly
Weak building construction
Water hitting fan blade
Unit oversized for application: compressor cycles on and off frequently
Tighten any loose parts.
Provide additional support for unit.
Normal in high humidity. Stop noise by removing drain plug or adding condensate drain cup.
Check with dealer to determine proper capacity unit for application.
MOUNTING SUPPORT NOT INSTALLED
Storm window frame installed in window Some models require removal of storm window frame before installation.
FROST ON INDOOR COIL Dirty air filter
Normal for low outdoor temperatures
Clean air filter by vacuuming or washing with water and mild soap.
Turning Temperature Control to warmer setting reduces occurrence and duration of frost.
FROST ON OUTDOOR COIL (heat pump models only)
Normal for outdoor temperatures at or below 45°F
Call for service only if unit does not heat room and you have checked all problems and remedies listed under LITTLE OR NO HEATING.
ODORS IN COOLING Mold, mildew, or algae formation on wet surfaces
To reduce algae growth, use algaecide tablet in base pan; remove drain plug; add condensate drain cup and hose. Thoroughly clean unit.
ODORS IN HEATING Normal for first time electric heater is used each season
Caused by dust accumulation during unused months.
Odor dissipates quickly with heater use.
The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause andsuggested remedies are given for each problem.If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.
WARNING
18
When Service Is RequiredYour room air conditioner dealer can give you the name ofyour nearest Authorized Service Center. Help them giveyou prompt service by providing:
• An accurate description of problem.• Complete model, serial, and manufacturing numbers
from serial plate.• Proof of purchase (sales receipt) upon request.
Repair by unauthorized servicer that results in subsequentfailure of unit voids warranty. Warranty details are con-tained in warranty certificate enclosed with unit.Keep accurate records of service calls, including what wasdone, servicer’s name, and date of service.
Any Questions?Most questions can be answered by your local dealer. If youhave other matters that cannot be resolved locally, or youneed additional information regarding other heating andcooling products offered by us - please call:
CONSUMER INFORMATION LINEAMANA TOLL FREE
1-877-376-0214 (U.S. and Canada only)email us at: [email protected]
fax us at: (713) 856-1821(Not a technical assistance line for dealers.)
Outside the U.S. and Canada, call 1-713-861-2500.(Not a technical assistance line for dealers.)
Your telephone company will bill you for the call.
19
is a
reg
iste
red
trade
mar
k of
May
tag
Cor
pora
tion
or it
s re
late
d co
mpa
nies
and
is u
sed
unde
r lic
ense
to G
oodm
an C
ompa
ny, L
.P.,
Hou
ston
, TX
. A
ll rig
hts
rese
rved
.
For
serv
ice,
con
tact
an
Auth
oriz
ed A
man
a® B
rand
Ser
vice
r.Fo
r an
swer
s to
que
stio
ns r
egar
ding
the
abov
e or
to lo
cate
an
auth
oriz
ed s
ervi
cer,
cont
act
Goo
dman
Con
sum
er A
ffairs
•
740
1 Se
curit
y W
ay
• H
oust
on, T
exas
770
401-
877-
254-
4729
insi
de U
.S.A
. •
1-7
13-8
61-2
500
outs
ide
U.S
.A.
©20
10 G
oodm
an C
ompa
ny, L
.P.
Part
No.
PW
-342
B5/
2010
LIM
ITE
D W
AR
RA
NTY
CO
NS
UM
ER
S
This
war
rant
y is
ext
ende
d on
ly t
o pu
rcha
sers
for
per
sona
l, fa
mily
or
hous
ehol
d us
e.
Adi
stin
ct w
arra
nty
is e
xten
ded
to c
omm
erci
al c
usto
mer
s.
Am
ana®
bra
nd R
AC
win
dow
-type
hea
ting
or a
ir co
nditi
onin
g un
its id
entif
ied
as A
E,
AH
,P
BC
, P
BE
and
PB
H u
nits
are
war
rant
ed b
y G
oodm
an C
ompa
ny,
L.P.
to
cons
umer
sag
ains
t de
fect
s in
mat
eria
ls a
nd w
orkm
ansh
ip u
nder
nor
mal
use
and
mai
nten
ance
, as
prov
ided
bel
ow.
FIR
ST-Y
EAR
CO
VER
AG
E (E
NTI
RE
UN
IT):
We
will
rep
air
or r
epla
ce,
free
of c
harg
e (to
incl
ude
labo
r),
any
part
of
a un
it th
at p
rove
s to
be
defe
ctiv
e du
e to
wor
kman
ship
or
mat
eria
ls w
ithin
the
firs
t ye
ar a
fter
the
date
of
purc
hase
.
SEC
ON
D T
HR
OU
GH
FIF
TH Y
EAR
S SE
ALE
D S
YSTE
M C
OVE
RA
GE:
D
urin
g th
e 2nd
thro
ugh
5th y
ears
afte
r th
e da
te o
f pu
rcha
se,
we
will
rep
air
(to in
clud
e la
bor)
any
ref
rig-
eran
t le
aks
caus
ed b
y de
fect
s in
wor
kman
ship
or
mat
eria
l of
a u
nit,
and
will
rep
air
orre
plac
e (to
incl
ude
labo
r) a
ny p
ortio
n of
the
eva
pora
tor
coil,
con
dens
er c
oil,
com
pres
sor,
reve
rsin
g va
lves
or
conn
ectin
g tu
bing
tha
t pr
oves
to
be d
efec
tive,
in
wor
kman
ship
or
mat
eria
ls.
If th
e da
te o
f pur
chas
e ca
nnot
be
verif
ied,
the
war
rant
y pe
riod
begi
ns th
ree
mon
ths
afte
rth
e m
onth
of
man
ufac
ture
(in
dica
ted
by t
he f
irst
four
dig
its o
f th
e un
it’s
seria
l nu
mbe
r(y
ymm
)).
Any
par
t re
plac
ed o
r le
ak r
epai
red
unde
r th
is w
arra
nty
is w
arra
nted
onl
y fo
r th
e un
ex-
pire
d po
rtion
of
the
orig
inal
war
rant
y te
rm.
The
abov
e re
med
ies
are
our
only
res
pons
ibili
ties,
and
the
con
sum
er’s
onl
y re
med
ies,
unde
r th
is w
arra
nty.
Fo
r w
arra
nty
cred
it, a
ny d
efec
tive
part
mus
t be
ret
urne
d to
an
Am
ana®
bra
nd h
eatin
g an
d ai
r co
nditi
onin
g pr
oduc
ts d
istr
ibut
or b
y an
aut
horiz
edA
man
a® b
rand
ser
vice
r; an
d al
l w
arra
nty
serv
ice
mus
t be
per
form
ed b
y an
aut
horiz
edA
man
a® b
rand
ser
vice
r. T
o lo
cate
an
auth
oriz
ed A
man
a® b
rand
ser
vice
r, co
ntac
tG
oodm
an C
ompa
ny C
onsu
mer
Affa
irs a
t th
e nu
mbe
r or
add
ress
fou
nd a
t th
e bo
ttom
of
this
cer
tific
ate.
Goo
dman
will
not
pay
for
ele
ctric
ity o
r fu
el c
osts
, or
incr
ease
s in
ele
ctric
ity o
r fu
el c
osts
,fo
r an
y re
ason
, in
clud
ing
addi
tiona
l or
unu
sual
use
of
supp
lem
enta
l el
ectri
c he
at.
Thi
sw
arra
nty
does
not
cov
er l
odgi
ng.
WA
RR
AN
TY L
IMIT
ATIO
NS:
WE
AR
E N
OT
RES
PON
SIB
LE F
OR
:
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of
fau
lty i
nsta
llatio
n or
app
licat
ion
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of f
lood
s, fi
res,
win
d, li
ghtn
ing,
acc
iden
ts, c
orro
sive
atm
osph
ere
or o
ther
con
ditio
ns b
eyon
d ou
r re
ason
able
con
trol
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of
the
use
of
com
pone
nts
or a
cces
sorie
s no
tco
mpa
tible
with
the
uni
t•
Uni
ts i
nsta
lled
outs
ide
of t
he U
nite
d S
tate
s an
d C
anad
a•
Nor
mal
mai
nten
ance
, as
des
crib
ed i
n th
e in
stal
latio
n an
d op
erat
ing
man
ual,
such
as
clea
ning
of
the
coils
, fil
ter
clea
ning
and
/or
repl
acem
ent,
or d
amag
e ca
used
by
failu
re t
ope
rfor
m s
uch
mai
nten
ance
•P
arts
or
acce
ssor
ies
not
supp
lied
or d
esig
nate
d fo
r us
e by
us
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of
any
im
prop
er u
se,
mai
nten
ance
, op
erat
ion
orse
rvic
ing
•D
amag
e or
fai
lure
to
star
t du
e to
int
erru
pted
and
/or
inad
equa
te e
lect
rical
ser
vice
•C
hang
es i
n th
e ap
pear
ance
of
the
unit
that
do
not
affe
ct i
ts p
erfo
rman
ce•
Rep
lace
men
t of
fus
es a
nd r
epla
cem
ent
or r
eset
ting
of c
ircui
t br
eake
rs
THIS
WA
RR
AN
TY IS
TH
E O
NLY
EXP
RES
S W
AR
RA
NTY
PR
OVI
DED
ON
TH
E U
NIT
S C
OVE
RED
;A
ND
AN
Y IM
PLIE
D W
AR
RA
NTI
ES, I
NC
LUD
ING
AN
Y IM
PLIE
D W
AR
RA
NTY
OF
MER
CH
AN
T-A
BIL
ITY
OR
FIT
NES
S FO
R A
PA
RTI
CU
LAR
PU
RPO
SE A
RE
LIM
ITED
TO
TH
E D
UR
ATIO
N O
FTH
IS W
AR
RA
NTY
. S
ome
stat
es d
o no
t allo
w li
mita
tions
on
how
long
an
impl
ied
war
rant
y la
sts,
so t
he a
bove
lim
itatio
n m
ay n
ot a
pply
to
you.
WH
ETH
ER A
NY
CLA
IM IS
BA
SED
ON
NEG
LIG
ENC
E O
R O
THER
TO
RT,
BR
EAC
H O
F W
AR
-R
AN
TY O
R O
THER
BR
EAC
H O
F C
ON
TRA
CT,
OR
AN
Y O
THER
TH
EORY
, IN
NO
EVE
NT
SHA
LLW
E B
E LI
AB
LE F
OR
INC
IDEN
TAL
OR
CO
NSE
QU
ENTI
AL
DA
MA
GES
, IN
CLU
DIN
G B
UT
NO
TLI
MIT
ED T
O L
OST
PR
OFI
TS, L
OSS
OF
USE
OF
A U
NIT
OR
OTH
ERW
ISE.
Som
e st
ates
do
not
allo
w t
he e
xclu
sion
or
limita
tion
of i
ncid
enta
l or
con
sequ
entia
l da
mag
es,
so t
he a
bove
excl
usio
n m
ay n
ot a
pply
to
you.
This
war
rant
y gi
ves
you
spec
ific
lega
l rig
hts,
and
you
may
als
o ha
ve o
ther
rig
hts
whi
ch v
ary
from
sta
te t
o st
ate.
Mod
el #
& S
eria
l #__
____
____
____
____
____
____
____
___
D
ate
of P
urch
ase
____
____
____
____
____
____
____
____
_
RA
C W
IND
OW
TYP
E H
& C
(AE,
AH
, PB
C, P
BE,
PB
H)
20
is a
reg
iste
red
trade
mar
k of
May
tag
Cor
pora
tion
or it
s re
late
d co
mpa
nies
and
is u
sed
unde
r lic
ense
to G
oodm
an C
ompa
ny, L
.P.,
Hou
ston
, TX
. A
ll rig
hts
rese
rved
.
For
serv
ice,
con
tact
an
Auth
oriz
ed A
man
a® B
rand
Ser
vice
r.Fo
r an
swer
s to
que
stio
ns r
egar
ding
the
abov
e or
to lo
cate
an
auth
oriz
ed s
ervi
cer,
cont
act
Goo
dman
Con
sum
er A
ffairs
•
740
1 Se
curit
y W
ay
• H
oust
on, T
exas
770
401-
877-
254-
4729
insi
de U
.S.A
. •
1-7
13-8
61-2
500
outs
ide
U.S
.A.
©20
10 G
oodm
an C
ompa
ny, L
.P.
Par
t No.
PW
-343
5/20
10
WA
RR
AN
TY T
O C
OM
ME
RC
IAL
CU
STO
ME
RS
This
war
rant
y is
ext
ende
d to
com
mer
cial
cus
tom
ers
only
. A
dis
tinct
war
rant
y is
exte
nded
to
purc
hase
rs f
or p
erso
nal,
fam
ily o
r ho
useh
old
use.
Am
ana®
bra
nd R
AC
win
dow
-type
hea
ting
or a
ir co
nditi
onin
g un
its id
entif
ied
as A
E,
AH
, PB
C, P
BE
and
PB
H u
nits
are
war
rant
ed b
y G
oodm
an C
ompa
ny, L
.P. t
o co
mm
erci
alcu
stom
ers
agai
nst
defe
cts
in m
ater
ials
and
wor
kman
ship
und
er n
orm
al u
se a
ndm
aint
enan
ce,
as p
rovi
ded
belo
w.
FIR
ST-Y
EAR
CO
VER
AG
E (E
NTI
RE
UN
IT):
We
will
repa
ir or
repl
ace,
free
of c
harg
e(to
incl
ude
labo
r),
any
part
of a
uni
t th
at p
rove
s to
be
defe
ctiv
e du
e to
wor
kman
ship
or m
ater
ials
with
in t
he f
irst
year
afte
r th
e da
te o
f pu
rcha
se.
SEC
ON
D T
HR
OU
GH
FIF
TH Y
EAR
S SE
ALE
D S
YSTE
M C
OVE
RA
GE:
Dur
ing
the
2nd
thro
ugh
5th y
ears
afte
r th
e da
te o
f pu
rcha
se,
we
will
rep
air
(to i
nclu
de l
abor
) an
yre
frige
rant
lea
ks c
ause
d by
def
ects
in
wor
kman
ship
or
mat
eria
l of
a u
nit,
and
will
repa
ir or
rep
lace
(to
incl
ude
labo
r) a
ny p
ortio
n of
the
evap
orat
or c
oil,
cond
ense
r co
il,co
mpr
esso
r, re
vers
ing
valv
es o
r co
nnec
ting
tubi
ng t
hat
prov
es t
o be
def
ectiv
e, i
nw
orkm
ansh
ip o
r m
ater
ials
.
If th
e da
te o
f pur
chas
e ca
nnot
be
verif
ied,
the
war
rant
y pe
riod
begi
ns th
ree
mon
ths
afte
r th
e m
onth
of
man
ufac
ture
(in
dica
ted
by t
he f
irst
four
dig
its o
f th
e un
it’s
seria
lnu
mbe
r (y
ymm
)).
Any
par
t re
plac
ed o
r le
ak r
epai
red
unde
r th
is w
arra
nty
is w
arra
nted
onl
y fo
r th
eun
expi
red
porti
on o
f th
e or
igin
al w
arra
nty
term
.
The
abov
e re
med
ies
are
our o
nly
resp
onsi
bilit
ies,
and
the
cust
omer
’s o
nly
rem
edie
s,un
der
this
war
rant
y.
For
war
rant
y cr
edit,
any
def
ectiv
e pa
rt m
ust
be r
etur
ned
to a
nA
man
a® b
rand
hea
ting
and
air
cond
ition
ing
prod
ucts
dis
tribu
tor
by a
n au
thor
ized
Am
ana®
bra
nd s
ervi
cer;
and
all w
arra
nty
serv
ice
mus
t be
per
form
ed b
y an
aut
ho-
rized
Am
ana®
bra
nd s
ervi
cer.
To
loca
te a
n au
thor
ized
Am
ana®
bra
nd s
ervi
cer,
cont
act G
oodm
an C
ompa
ny C
onsu
mer
Affa
irs a
t the
num
ber o
r add
ress
foun
d at
the
botto
m o
f th
is c
ertif
icat
e.
Mod
el #
& S
eria
l #__
____
____
____
____
____
____
____
___
D
ate
of P
urch
ase
____
____
____
____
____
____
____
____
_
Goo
dman
will
not
pay
for
ele
ctric
ity o
r fu
el c
osts
, or
inc
reas
es i
n el
ectri
city
or
fuel
cost
s, fo
r any
reas
on, i
nclu
ding
add
ition
al o
r unu
sual
use
of s
uppl
emen
tal e
lect
ric h
eat.
This
war
rant
y do
es n
ot c
over
lodg
ing.
WA
RR
AN
TY L
IMIT
ATIO
NS:
WE
AR
E N
OT
RES
PON
SIB
LE F
OR
:
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of f
aulty
inst
alla
tion
or a
pplic
atio
n•
Dam
age
or r
epai
rs r
equi
red
as a
res
ult o
f flo
ods,
fire
s, w
ind,
ligh
tnin
g, a
ccid
ents
,co
rros
ive
atm
osph
ere
or o
ther
con
ditio
ns b
eyon
d ou
r re
ason
able
con
trol
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of
the
use
of
com
pone
nts
or a
cces
sorie
sno
t com
patib
le w
ith th
e un
it•
Uni
ts in
stal
led
outs
ide
of th
e U
nite
d St
ates
and
Can
ada
•N
orm
al m
aint
enan
ce, a
s de
scrib
ed in
the
inst
alla
tion
and
oper
atin
g m
anua
l, su
ch a
scl
eani
ng o
f th
e co
ils,
filte
r cl
eani
ng a
nd/o
r re
plac
emen
t, or
dam
age
caus
ed b
yfa
ilure
to
perfo
rm s
uch
mai
nten
ance
•P
arts
or
acce
ssor
ies
not
supp
lied
or d
esig
nate
d fo
r us
e by
us
•D
amag
e or
rep
airs
req
uire
d as
a r
esul
t of a
ny im
prop
er u
se, m
aint
enan
ce, o
pera
-tio
n or
ser
vici
ng•
Dam
age
or fa
ilure
to s
tart
due
to in
terr
upte
d an
d/or
inad
equa
te e
lect
rical
ser
vice
•C
hang
es in
the
appe
aran
ce o
f the
uni
t tha
t do
not a
ffect
its
perfo
rman
ce•
Rep
lace
men
t of
fus
es a
nd r
epla
cem
ent
or r
eset
ting
of c
ircui
t br
eake
rs
THIS
WA
RR
AN
TY IS
PR
OVI
DED
IN L
IEU
OF
AN
Y O
THER
WA
RR
AN
TIES
, EXP
RES
S O
RIM
PLIE
D, I
NC
LUD
ING
AN
Y IM
PLIE
D W
AR
RA
NTY
OF
MER
CH
AN
TAB
ILIT
Y O
R F
IT-
NES
S FO
R A
PA
RTI
CU
LAR
PU
RPO
SE.
WH
ETH
ER A
NY
CLA
IM IS
BA
SED
ON
NEG
LI-
GEN
CE
OR
OTH
ER T
OR
T, B
REA
CH
OF
WA
RR
AN
TY O
R O
THER
BR
EAC
H O
F C
ON
-TR
AC
T, O
R A
NY
OTH
ER T
HEO
RY, I
N N
O E
VEN
T SH
ALL
WE
BE
LIA
BLE
FO
R IN
CID
EN-
TAL
OR
CO
NSE
QU
ENTI
AL
DA
MA
GES
, IN
CLU
DIN
G B
UT
NO
T LI
MIT
ED T
O L
OST
PRO
FITS
, LO
SS O
F U
SE O
F A
UN
IT O
R O
THER
WIS
E.
RA
C W
IND
OW
TYP
E H
& C
(AE,
AH
, PB
C, P
BE,
PB
H)
66129904238