STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA Test Model: JLS68103-G60-ACTR Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Off-state Power Test Engineer: Daniel Duan Report Number: RSZ140120504-10 Test Date: 2014-03-06 to 2014-03-22 Report Date: 2014-03-31 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Upload: lamthien

Post on 16-Mar-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08

MEASUREMENT AND TEST REPORT For

Jaykal LED Solutions, Inc

35765 Black Marlin Drive Lewes, Delaware 19958, USA

Test Model: JLS68103-G60-ACTR

Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Off-state Power

Test Engineer: Daniel Duan

Report Number: RSZ140120504-10

Test Date: 2014-03-06 to 2014-03-22

Report Date: 2014-03-31

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

Sample No.: RSZ140120504-S01 Model: JLS68103-G60-ACTR One sample was received on 2014-01-20 and used for testing.

Model Tested: JLS68103-G60-ACTR

Manufacturer: Jaykal LED Solutions, Inc

Brand Name: Jaykal LED Solutions, Inc

Product Designation: Outdoor Pole/Arm-Mounted Decorative Luminaires

Burning Time Before Test: 0 hour(For New Products)

Rated Values:

Rated Voltage/Frequency: 90-277 VAC 50/60Hz

Rated Power: 60W

Nominal CCT: 5700K

Nominal CRI: 75

2. Standards Used

• IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products • ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration date

1.5m temperature integrating sphere SENSING SPR-600 S09008 25~50℃ N/A

Spectral radiation analyzer SENSING SPR3000 90902027 350nm~800nm N/A

Digital power meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2013-03-25

Precision frequency power supply ALL Power APW-105N 970613 0V-300V 50-400Hz 2013-03-25

Standard Light Source SENSING N/A LSD090808 N/A 2013-05-13

Temperature/humidity/clock Victor VC230 EE209 0~40℃0~90% 2013-04-01

Programmable Precision DC Power Supply ITECH IT6154 0061 0417

6471 0010 19 0~60V 2013-03-25

AC POWER SUPPLY EVERFINE VPS1060 PWM 1101006 0-150V, 0-300V 2013-03-25

Digital CC&CV DC Power Supply EVERFINE WY12010 1009009 30V/5A 2013-03-25

Electrical parameter tester YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2013-03-25

full-field speed goniophotometer EVERFINE GO-R5000 YG108492N1

0120001 1600mm,3000W/10A N/A

Temperature/humidity/clock Victor VC230 EE091 0~40℃0~90% 2013-04-01

Standard Light Source EVERFINE D908 1012001 N/A 2013-05-28 Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

Page 3: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Page 4: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.5 hours

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

120.04 60.0 0.441 52.09 0.984

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

3108.392 5.080 59.673 5702 5.00E-03

Chromaticity Coordinate

x y u v u' v'

0.3278 0.3468 0.2015 0.3139 0.2015 0.4797

Color Rendering Index

Ra

74.7

R1 R2 R3 R4

73 77 82 77

R5 R6 R7 R8

75 71 80 62

R9 R10 R11 R12

-18 48 77 58

R13 R14 R15 73 90 66

Page 5: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW nm mW nm mW

nm mW

380 2.941E-03 465 4.578E-02 550 1.287E-01 635 6.622E-02 720 7.655E-03

385 1.580E-03 470 3.664E-02 555 1.293E-01 640 5.979E-02 725 6.702E-03

390 1.344E-03 475 3.562E-02 560 1.301E-01 645 5.405E-02 730 5.760E-03

395 1.259E-03 480 3.866E-02 565 1.300E-01 650 4.856E-02 735 5.175E-03

400 1.479E-03 485 4.602E-02 570 1.300E-01 655 4.323E-02 740 4.683E-03

405 2.819E-03 490 5.693E-02 575 1.283E-01 660 3.847E-02 745 3.906E-03

410 7.092E-03 495 6.772E-02 580 1.252E-01 665 3.407E-02 750 3.575E-03

415 1.644E-02 500 7.862E-02 585 1.218E-01 670 3.033E-02 755 3.149E-03

420 3.500E-02 505 8.831E-02 590 1.183E-01 675 2.645E-02 760 2.763E-03

425 6.755E-02 510 9.685E-02 595 1.136E-01 680 2.344E-02 765 2.416E-03

430 1.146E-01 515 1.036E-01 600 1.082E-01 685 2.033E-02 770 2.182E-03

435 1.747E-01 520 1.093E-01 605 1.036E-01 690 1.778E-02 775 2.057E-03

440 2.308E-01 525 1.142E-01 610 9.789E-02 695 1.549E-02 780 1.834E-03

445 2.145E-01 530 1.189E-01 615 9.213E-02 700 1.352E-02 785 1.631E-03

450 1.420E-01 535 1.216E-01 620 8.518E-02 705 1.158E-02 790 1.396E-03

455 9.053E-02 540 1.248E-01 625 7.834E-02 710 1.013E-02 795 1.402E-03

460 6.464E-02 545 1.270E-01 630 7.271E-02 715 8.766E-03 800 1.247E-03

0.0 

0.2 

0.4 

0.6 

0.8 

1.0 

1.2 

380 440 500 560 620 680 740 800

Page 6: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Report No

o. RSZ140120

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0.30

0.35

0.40

0.45

0.30

0504-10

7-S

0 0.1

0

B

CIE 1931

Step & 4-Ste

0.2

0.35

Bay Area C6/F

Page 6 of 1

x y Chroma

ep Chromat

0.3 0.4

0.40

ComplianceF, the 3rd Phase o

12

aticity Diagr

ticity Quadr

0.5

0.4

e Laboratorof WanLi Industri

Free Trade Z

The NV

ram

rangles

0.6 0.7

5

ries Corp. (ial Building, ShiHZone Shenzhen, G

VLAP Lab Cod

0.8

0.50

(Shenzhen)Hua Road, FuTianGuangdong, China

de is 200707-0

sample7‐STEP 2700K7‐STEP 3000K7‐STEP 3500K7‐STEP 4000K7‐STEP 4500K7‐STEP 5000K7‐STEP 5700K7‐STEP 6500K4‐STEP 2700K4‐STEP 3000K4‐STEP 3500K4‐STEP 4000K4‐STEP 5000K4‐STEP 6500K

)n a

0.

KKKKKKKKKKKKKK

Page 7: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.5 hours

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

119.9 60.0 0.4415 52.13 0.9844

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

3130.26 60.05 288 2.49 2.28

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 126.3 125.7 128.6 122.4 125.8

Field Angle (10% Imax): 172.0 169.2 172.3 168.1 170.4

Page 8: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 288 287 287 286 285 285 284 284 5.0° 322 312 299 301 300 300 302 293 10.0° 395 361 366 364 349 345 357 348 15.0° 334 363 374 363 339 373 388 382 20.0° 364 373 428 434 469 482 483 469 25.0° 453 456 511 536 524 559 569 566 30.0° 480 535 584 572 583 623 645 617 35.0° 568 639 728 674 705 739 779 734 40.0° 753 785 897 813 820 849 917 872 45.0° 835 882 986 855 824 835 892 865 50.0° 809 857 912 781 750 756 738 768 55.0° 686 759 729 690 588 566 536 580 60.0° 599 631 570 517 448 430 403 434 65.0° 475 453 393 338 305 258 271 259 70.0° 337 260 224 192 184 166 175 170 75.0° 185 171 161 153 139 133 137 134 80.0° 143 137 131 120 106 109 109 105 85.0° 111 107 100 90 80 81 81 79 90.0° 80 80 75 72 67 68 69 67 95.0° 68 71 68 66 63 65 67 65

100.0° 67 68 67 66 64 65 66 64 105.0° 67 67 67 66 65 65 66 64 110.0° 67 67 68 66 66 66 68 65 115.0° 69 68 70 68 68 68 69 67 120.0° 70 69 72 69 68 68 69 67 125.0° 70 68 71 68 67 67 67 66 130.0° 67 65 69 65 62 61 62 60 135.0° 59 57 60 55 51 50 49 48 140.0° 45 44 45 42 37 35 35 36 145.0° 31 31 30 28 24 23 22 24 150.0° 20 19 18 17 15 13 12 14 155.0° 13 12 10 10 10 8 7 7 160.0° 7 7 5 4 5 5 4 4 165.0° 4 3 2 2 3 3 3 3 170.0° 3 2 2 2 3 3 3 2 175.0° 2 2 2 2 2 2 3 3 180.0° 3 3 3 3 2 2 2 2

Page 9: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 288 287 287 286 285 285 284 284 5.0° 302 309 314 320 319 317 322 313 10.0° 368 395 366 363 372 351 362 359 15.0° 340 350 378 366 328 363 382 352 20.0° 477 436 441 376 376 380 388 380 25.0° 551 542 520 462 460 456 455 446 30.0° 612 594 580 560 503 519 503 509 35.0° 720 703 714 662 584 588 608 574 40.0° 865 869 887 827 751 747 829 747 45.0° 831 927 990 938 847 908 1040 880 50.0° 694 848 936 871 801 904 1001 870 55.0° 561 690 783 776 707 845 881 776 60.0° 428 538 627 646 607 736 716 691 65.0° 299 357 435 477 479 581 597 547 70.0° 180 192 230 251 330 342 388 340 75.0° 135 147 158 169 178 194 200 188 80.0° 105 115 124 129 139 145 159 145 85.0° 78 87 93 101 113 113 120 118 90.0° 67 72 74 78 78 84 85 84 95.0° 64 67 68 68 67 70 70 69

100.0° 65 67 67 67 65 67 67 66 105.0° 65 67 67 67 66 67 67 66 110.0° 67 68 69 67 66 68 67 66 115.0° 68 70 71 68 68 69 69 68 120.0° 68 70 71 69 69 70 71 69 125.0° 67 69 70 68 69 69 71 69 130.0° 61 63 66 64 66 66 69 67 135.0° 49 51 55 55 56 59 63 60 140.0° 36 36 39 41 42 46 49 48 145.0° 24 24 25 27 29 32 34 34 150.0° 15 14 14 16 18 20 21 21 155.0° 9 8 7 9 11 12 12 12 160.0° 5 5 4 5 7 7 6 6 165.0° 4 4 4 4 4 3 3 3 170.0° 3 3 3 3 3 3 3 3 175.0° 2 2 2 3 3 3 2 2 180.0° 2 2 2 2 2 2 2 2

Page 10: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Report No

Average

Angl

o. RSZ140120

e Area Illum

e: 125.8°. Fl

0504-10

ination Figu

lux out: 225

B

ure

52.0 lm.

Bay Area C6/F

Page 10 of

Heigh

0

1

1

2

2

3

3

4

4

5

ComplianceF, the 3rd Phase o

12

ht (m) Diam(c

.5 19

.0 39

.5 58

.0 78

.5 97

.0 117

.5 136

.0 156

.5 175

.0 195

e Laboratorof WanLi Industri

Free Trade Z

The NV

meter cm) Ea

95.4 74

90.8 18

86.3 8

81.7 4

77.1 2

72.5 2

67.9 1

63.3 1

58.8 9

54.2 7

ries Corp. (ial Building, ShiHZone Shenzhen, G

VLAP Lab Cod

avg(lx) E

44.4 1

86.1 4

82.7 1

46.5 1

29.8

20.7 4

15.2

11.6 2

9.2 2

7.4

(Shenzhen)Hua Road, FuTianGuangdong, China

de is 200707-0

max(lx)

723.0

430.8

191.5

107.7

68.9

47.9

35.2

26.9

21.3

17.2

)n a

0.

Page 11: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) % Deg Flux (lm) %

0-5 7.1 0.23 0-5 7.1 0.23

5-10 24.4 0.78 0-10 31.5 1.01

10-15 42.9 1.36 0-15 74.3 2.37

15-20 63.7 2.04 0-20 138.1 4.41

20-25 97.9 3.13 0-25 235.9 7.54

25-30 135.2 4.32 0-30 371.1 11.86

30-35 180.4 5.76 0-35 551.5 17.62

35-40 249.8 7.98 0-40 801.3 25.60

40-45 324.2 10.35 0-45 1125.5 35.95

45-50 353.0 11.28 0-50 1478.4 47.23

50-55 333.3 10.65 0-55 1811.8 57.88

55-60 290.0 9.26 0-60 2101.8 67.14

60-65 237.1 7.58 0-65 2338.8 74.72

65-70 165.6 5.29 0-70 2504.4 80.01

70-75 102.5 3.27 0-75 2606.9 83.28

75-80 76.3 2.44 0-80 2683.1 85.72

80-85 60.5 1.93 0-85 2743.6 87.65

85-90 46.8 1.49 0-90 2790.4 89.14

90-95 38.4 1.23 0-95 2828.8 90.37

95-100 36.1 1.15 0-100 2864.9 91.52

100-105 35.4 1.13 0-105 2900.3 92.65

105-110 34.8 1.11 0-110 2935.0 93.76

110-115 34.3 1.10 0-115 2969.4 94.86

115-120 33.6 1.07 0-120 3002.9 95.93

120-125 31.9 1.02 0-125 3034.8 96.95

125-130 29.1 0.93 0-130 3064.0 97.88

130-135 24.4 0.78 0-135 3088.3 98.66

135-140 17.9 0.57 0-140 3106.2 99.23

140-145 11.4 0.37 0-145 3117.6 99.60

145-150 6.5 0.20 0-150 3124.1 99.80

150-155 3.3 0.11 0-155 3127.4 99.91

155-160 1.6 0.05 0-160 3129.0 99.96

160-165 0.7 0.02 0-165 3129.7 99.98

165-170 0.3 0.01 0-170 3130.0 99.99

170-175 0.2 0.01 0-175 3130.2 100.00

175-180 0.1 0.00 0-180 3130.3 100.00

Page 12: RSZ140120504-10 JAYKAL JLS68103-G60-ACTR LM-79 · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories

Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140120504-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Power Factor: 277 60 0.8817

Total Harmonic Distortion: 120 60 16.01%

Total Harmonic Distortion: 277 60 23.4%

Off State Power (W): 120 60 0.0

6. Product Photo

***********END OF REPORT***********